Footing- F1

For Columns- 61, 68, 75, 82 & 89

Geometry Data
Item
Col. Length( X-dirn)
Col. Width (Y-dirn)
Ratio (Length/Width)
Thickness at Edge
Thickness at ColFace
Depth of Foundation
Depth of Footing (Assume)

Value

Unit
0.45
0.25
1.8
0.15
0.85
1.8
250

m
m
m
m
m
mm

Load Data
Item

Value

Unit
273 kN

Factored Axial
Materials Data
Item
Bearing Capacity of Soil
Unit Wt. of Soil
Grade of Concrete
Grade of Steel
Unit Wt. of Conc.

Value

Unit
120 kN/m2
1800 kg/m3
M20
Fe 415
2500 kg/m3

Reinforcement Data
Item
Dia of bar at bot.along X (mm)
Dia of bar at bot.along Y (mm)
Min. Bar Spacing
Max. Bar Spacing
Clear Cover

Value

Unit
12
12
0.04 m
0.3 m
0.06 m

113
113

Approximate Footing Size Calculations


Total maximum vertical load ( P max )
Approx weight of Foundation ( W fdn ) [5 percent of P max ,assumed]
Total Vertical Load ( Pv ) = P + W
Approximate area of the footing ( Area approx ) = P / Q
max

273.00
14.00
287.00

fdn

2.39

all

Keeping equal projection on either side of column,


Projection
Approx length of footing
Approx Width of footing
Area Provided

600
1650
1450

Footings

Say
Say

1700
1500
2.55

Calculation of Actual size & pressure of the footing


Thickness of footing at column face ( OverAll col ) mm
Unit weight of Concrete ( c ) = 25 kN/cub. m
Dimension of the column along X-Direction (BCol x )
Dimension of the column along Y-Direction (BCol y )
Depth of Foundation from soil surface (Fdndepth )
Unit weight of soil ( s ) = 17.615 kN/cub. m
Pressure on foundation ( Pr dlw ) kN/sq.m

450.00
250.00
1800.00
107.06

Q All > Q Max Hence OK.

Thickness of mat in Flexure Case:


Projection on either side of Column
Maximum upward soil pressure under the foundation(Pr
Max Moment on foundation at column face( Mx design )

Design

625.00
107.06

) kN/sq.m

Prdesign* ((Bx- BColx)*Bx / 2) 2 = kNm per m length


Characteristic strength of concrete (f ck ) =
N/sq.mm
Yeild strength of reinforcing steel (f y ) =
N/sq.mm
Overall thickness of the foundation at the face (OverAll edge ) mm
Clear cover to the outermost reinforcement bar (CL Foot ) mm
Dia of bottom reinforcement in X-direction ( x ) mm
Dia of bottom reinforcement in Y-direction ( y ) mm
Reqd thickness of the footing at column face in X-direction (Tcol x )

Overall thickness of the footing-- Assumed


Effective thickness of the footing at column face in

35.55
20
415
150.00
60.00
12.00
12.00
113.49

250.00

X-direction (Tcol x ) mm

Limiting MU/BD of the footing section =


2

184.00

2.76 N/sq.mm

Calculated MU/BD 2 in X direction = 0.387 N/sq.mm


Calculated MU/BD 2 in X direction < Limiting MU/BD 2 Hence OK.

1.05

Thickness of mat in One Way Shear Case:


Critical section lies at a distance of 'd' from face of column.
Depth at critical section
Upward shear force on footing at the critical section parallel to Y-axis (SF x )

155.00

kN
80.26

Shear stress at the critical section parallel to Y-axis

( ) N/sq.mm
vx

0.35

Maximum permissible shear stress of concrete ( ) for M 20 = 2.800 N/sq.mm


Design shear strength for 0.25% steel ( Tc)
0.36 N/sq.mm
cmax

OK
Footings

Punching Shear Calculation


Ratio of minimum to maximum dimension of column ( )
Value of K
Critical section lies at a distance of 'd/2' from face of column.
Minimum thickness of footing at critical section of punching shear (D Punch )
Perimeter of the punching shear zone (Peri Punch ) = 4512.000 mm
Area of the punching shear zone (AreaPunch ) = 1261148.000 sq. mm
Shear force for punching (SF punch ) = Pr * (B * B - Area ) kN

0.56
1.00

design

169.00
2136.00
0.28
243.54

Punch

Actual punching shear stress ( ) = SF / (Peri * D ) N/sq.mm


Allowable punching shear stress (
) = K * 0.25 * SQRT(f ) N/sq.mm

> Hence OK.


vPunch

punch

AllPunch

Punch

0.67

Punch

5.00

ck

AllPunch

vPunch

Area of Steel
Required Area of steel reinforcement in X-direction at bottom
(AstBottom x ) sq. mm per m length
Required Spacing of the bottom reinforcement along X-direction (Sp x )

572.00 Sqmm/m
195 mm

Minimum allowable bar spacing (Sp min ) = 40.000 mm


Maximum allowable bar spacing (Sp max ) = 300.000 mm

Development Length Calculation


Permissible tensile stress of steel ( ) = 230.000 N
Design bond stress ( ) = 1.200 N
Allowable development length along X-direction
(LdevAllx ) = sst* f x/ (4.0 * tbd) = 575.000 mm
Allowable development length along Y-direction
(LdevAlly ) = sst* f y/ (4.0 * tbd) = 575.000 mm
Actual development length along X-direction
(LdevActx ) = 0.5 * (Bx- BColx) - 50 cover

230.00

st

1.20

bd

575.00
575.00
575.00

LdevActx > LdevAllx Hence OK.


Design Summary:
Length
Width
Depth at Col face
Depth at Edge

Reinf

12

Footings

1700.00
1500.00
250.00
150.00
dia @ 195 mm

centres both ways

Footing- F2
For Columns- 63 to 67, 78,79, 81, 91 to 95

Geometry Data
Item
Col. Length( X-dirn)
Col. Width (Y-dirn)
Ratio (Length/Width)
Thickness at Edge
Thickness at ColFace
Depth of Foundation
Depth of Footing (Assume)

Value

Unit
0.45
0.25
1.8
0.2
0.85
1.8
450

m
m
m
m
m
mm

Load Data
Item

Value

Unit
592 kN

Factored Axial
Materials Data
Item
Bearing Capacity of Soil
Unit Wt. of Soil
Grade of Concrete
Grade of Steel
Unit Wt. of Conc.

Value

Unit
120 kN/m2
1800 kg/m3
M20
Fe 415
2500 kg/m3

Reinforcement Data
Item
Dia of bar at bot.along X (mm)
Dia of bar at bot.along Y (mm)
Min. Bar Spacing
Max. Bar Spacing
Clear Cover

Value

Unit
12
12
0.04 m
0.3 m
0.06 m

113
113

Approximate Footing Size Calculations


Total maximum vertical load ( P max )
Approx weight of Foundation ( W fdn ) [5 percent of P max ,assumed]
Total Vertical Load ( Pv ) = P + W
Approximate area of the footing ( Area approx ) = P / Q
max

592.00
30.00
622.00

fdn

5.18

all

Keeping equal projection on either side of column,


Projection
Approx length of footing
Approx Width of footing
Area Provided

964
2378
2178

Say
Say

2400
2200
5.28

Calculation of Actual size & pressure of the footing


Thickness of footing at column face ( OverAll col ) mm
Unit weight of Concrete ( c ) = 25 kN/cub. m
Footings

Dimension of the column along X-Direction (BCol x )


Dimension of the column along Y-Direction (BCol y )
Depth of Foundation from soil surface (Fdndepth )
Unit weight of soil ( s ) = 17.615 kN/cub. m
Pressure on foundation ( Pr dlw ) kN/sq.m

450.00
250.00
1800.00
112.12

Q All > Q Max Hence OK.

Thickness of mat in Flexure Case:


Projection on either side of Column
Maximum upward soil pressure under the foundation(Pr
Max Moment on foundation at column face( Mx design )

Design

975.00
112.12

) kN/sq.m

Prdesign* ((Bx- BColx)*Bx / 2) 2 = kNm per m length


Characteristic strength of concrete (f ck ) =
N/sq.mm
Yeild strength of reinforcing steel (f y ) =
N/sq.mm
Overall thickness of the foundation at the face (OverAll edge ) mm
Clear cover to the outermost reinforcement bar (CL Foot ) mm
Dia of bottom reinforcement in X-direction ( x ) mm
Dia of bottom reinforcement in Y-direction ( y ) mm
Reqd thickness of the footing at column face in X-direction (Tcol x )

Overall thickness of the footing-- Assumed


Effective thickness of the footing at column face in

127.90
20
415
200.00
60.00
12.00
12.00
215.27

450.00

X-direction (Tcol x ) mm

Limiting MU/BD of the footing section =


2

384.00

2.76 N/sq.mm

Calculated MU/BD 2 in X direction = 0.387 N/sq.mm


Calculated MU/BD 2 in X direction < Limiting MU/BD 2 Hence OK.

0.87

Thickness of mat in One Way Shear Case:


Critical section lies at a distance of 'd' from face of column.
Depth at critical section
Upward shear force on footing at the critical section parallel to Y-axis (SF x )

286.00

kN
159.03

( ) N/sq.mm

Shear stress at the critical section parallel to Y-axis

vx

0.25

Maximum permissible shear stress of concrete ( ) for M 20 = 2.800 N/sq.mm


Design shear strength for 0.25% steel ( Tc)
0.36 N/sq.mm
cmax

OK

Punching Shear Calculation


Ratio of minimum to maximum dimension of column ( )
c

Footings

0.56
5

Value of K
Critical section lies at a distance of 'd/2' from face of column.
Minimum thickness of footing at critical section of punching shear (D Punch )
Perimeter of the punching shear zone (Peri Punch ) = 4512.000 mm
Area of the punching shear zone (AreaPunch ) = 1261148.000 sq. mm
Shear force for punching (SF punch ) = Pr * (B * B - Area ) kN

1.00

design

335.00
2936.00
0.53
532.72

Punch

Actual punching shear stress ( ) = SF / (Peri * D ) N/sq.mm


Allowable punching shear stress (
) = K * 0.25 * SQRT(f ) N/sq.mm

> Hence OK.


vPunch

punch

AllPunch

Punch

0.54

Punch

5.00

ck

AllPunch

vPunch

Area of Steel
Required Area of steel reinforcement in X-direction at bottom
(AstBottom x ) sq. mm per m length
Required Spacing of the bottom reinforcement along X-direction (Sp x )

974.00 Sqmm/m
115 mm

Minimum allowable bar spacing (Sp min ) = 40.000 mm


Maximum allowable bar spacing (Sp max ) = 300.000 mm

Development Length Calculation


Permissible tensile stress of steel ( ) = 230.000 N
Design bond stress ( ) = 1.200 N
Allowable development length along X-direction
(LdevAllx ) = sst* f x/ (4.0 * tbd) = 575.000 mm
Allowable development length along Y-direction
(LdevAlly ) = sst* f y/ (4.0 * tbd) = 575.000 mm
Actual development length along X-direction
(LdevActx ) = 0.5 * (Bx- BColx) - 50 cover

230.00

st

1.20

bd

575.00
575.00
925.00

LdevActx > LdevAllx Hence OK.


Design Summary:
Length
Width
Depth at Col face
Depth at Edge

Reinf

12

Footings

2400.00
2200.00
450.00
200.00
dia @ 115 mm

centres both ways

Footing- F3
For Columns- 62, 71 to 74, 80, 85 to 87, 90

Geometry Data
Item
Col. Length( X-dirn)
Col. Width (Y-dirn)
Ratio (Length/Width)
Thickness at Edge
Thickness at ColFace
Depth of Foundation
Depth of Footing (Assume)

Value

Unit
0.45
0.25
1.8
0.2
0.85
1.8
600

m
m
m
m
m
mm

Load Data
Item

Value

Unit
691 kN

Factored Axial
Materials Data
Item
Bearing Capacity of Soil
Unit Wt. of Soil
Grade of Concrete
Grade of Steel
Unit Wt. of Conc.

Value

Unit
120 kN/m2
1800 kg/m3
M20
Fe 415
2500 kg/m3

Reinforcement Data
Item
Dia of bar at bot.along X (mm)
Dia of bar at bot.along Y (mm)
Min. Bar Spacing
Max. Bar Spacing
Clear Cover

Value

Unit
12
12
0.04 m
0.3 m
0.06 m

113
113

Approximate Footing Size Calculations


Total maximum vertical load ( P max )
Approx weight of Foundation ( W fdn ) [5 percent of P max ,assumed]
Total Vertical Load ( Pv ) = P + W
Approximate area of the footing ( Area approx ) = P / Q
max

691.00
35.00
726.00

fdn

6.05

all

Keeping equal projection on either side of column,


Projection
Approx length of footing
Approx Width of footing
Area Provided

1056
2562
2362

Say
Say

2600
2400
6.24

Calculation of Actual size & pressure of the footing


Thickness of footing at column face ( OverAll col ) mm
Unit weight of Concrete ( c ) = 25 kN/cub. m
Footings

Dimension of the column along X-Direction (BCol x )


Dimension of the column along Y-Direction (BCol y )
Depth of Foundation from soil surface (Fdndepth )
Unit weight of soil ( s ) = 17.615 kN/cub. m
Pressure on foundation ( Pr dlw ) kN/sq.m

450.00
250.00
1800.00
110.74

Q All > Q Max Hence OK.

Thickness of mat in Flexure Case:


Projection on either side of Column
Maximum upward soil pressure under the foundation(Pr
Max Moment on foundation at column face( Mx design )

Design

1075.00
110.74

) kN/sq.m

Prdesign* ((Bx- BColx)*Bx / 2) 2 = kNm per m length


Characteristic strength of concrete (f ck ) =
N/sq.mm
Yeild strength of reinforcing steel (f y ) =
N/sq.mm
Overall thickness of the foundation at the face (OverAll edge ) mm
Clear cover to the outermost reinforcement bar (CL Foot ) mm
Dia of bottom reinforcement in X-direction ( x ) mm
Dia of bottom reinforcement in Y-direction ( y ) mm
Reqd thickness of the footing at column face in X-direction (Tcol x )

Overall thickness of the footing-- Assumed


Effective thickness of the footing at column face in

166.36
20
415
200.00
60.00
12.00
12.00
245.51

600.00

X-direction (Tcol x ) mm

Limiting MU/BD of the footing section =


2

534.00

2.76 N/sq.mm

Calculated MU/BD 2 in X direction = 0.387 N/sq.mm


Calculated MU/BD 2 in X direction < Limiting MU/BD 2 Hence OK.

0.58

Thickness of mat in One Way Shear Case:


Critical section lies at a distance of 'd' from face of column.
Depth at critical section
Upward shear force on footing at the critical section parallel to Y-axis (SF x )

335.00

kN
155.76

( ) N/sq.mm

Shear stress at the critical section parallel to Y-axis

vx

0.19

Maximum permissible shear stress of concrete ( ) for M 20 = 2.800 N/sq.mm


Design shear strength for 0.25% steel ( Tc)
0.36 N/sq.mm
cmax

OK

Punching Shear Calculation


Ratio of minimum to maximum dimension of column ( )
c

Footings

0.56
8

Value of K
Critical section lies at a distance of 'd/2' from face of column.
Minimum thickness of footing at critical section of punching shear (D Punch )
Perimeter of the punching shear zone (Peri Punch ) = 4512.000 mm
Area of the punching shear zone (AreaPunch ) = 1261148.000 sq. mm
Shear force for punching (SF punch ) = Pr * (B * B - Area ) kN

1.00

design

435.00
3536.00
0.77
605.57

Punch

Actual punching shear stress ( ) = SF / (Peri * D ) N/sq.mm


Allowable punching shear stress (
) = K * 0.25 * SQRT(f ) N/sq.mm

> Hence OK.


vPunch

punch

AllPunch

Punch

0.39

Punch

5.00

ck

AllPunch

vPunch

Area of Steel
Required Area of steel reinforcement in X-direction at bottom
(AstBottom x ) sq. mm per m length
Required Spacing of the bottom reinforcement along X-direction (Sp x )

894.00 Sqmm/m
125 mm

Minimum allowable bar spacing (Sp min ) = 40.000 mm


Maximum allowable bar spacing (Sp max ) = 300.000 mm

Development Length Calculation


Permissible tensile stress of steel ( ) = 230.000 N
Design bond stress ( ) = 1.200 N
Allowable development length along X-direction
(LdevAllx ) = sst* f x/ (4.0 * tbd) = 575.000 mm
Allowable development length along Y-direction
(LdevAlly ) = sst* f y/ (4.0 * tbd) = 575.000 mm
Actual development length along X-direction
(LdevActx ) = 0.5 * (Bx- BColx) - 50 cover

230.00

st

1.20

bd

575.00
575.00
1025.00

LdevActx > LdevAllx Hence OK.


Design Summary:
Length
Width
Depth at Col face
Depth at Edge

Reinf

12

Footings

2600.00
2400.00
600.00
200.00
dia @ 125 mm

centres both ways

Footing- F4
For Columns- 70,77, 84, 88

Geometry Data
Item
Col. Length( X-dirn)
Col. Width (Y-dirn)
Ratio (Length/Width)
Thickness at Edge
Thickness at ColFace
Depth of Foundation
Depth of Footing (Assume)

Value

Unit
0.45
0.25
1.8
0.2
0.85
1.8
600

m
m
m
m
m
mm

Load Data
Item

Value

Unit
778 kN

Factored Axial
Materials Data
Item
Bearing Capacity of Soil
Unit Wt. of Soil
Grade of Concrete
Grade of Steel
Unit Wt. of Conc.

Value

Unit
120 kN/m2
1800 kg/m3
M20
Fe 415
2500 kg/m3

Reinforcement Data
Item
Dia of bar at bot.along X (mm)
Dia of bar at bot.along Y (mm)
Min. Bar Spacing
Max. Bar Spacing
Clear Cover

Value

Unit
12
12
0.04 m
0.3 m
0.06 m

113
113

Approximate Footing Size Calculations


Total maximum vertical load ( P max )
Approx weight of Foundation ( W fdn ) [5 percent of P max ,assumed]
Total Vertical Load ( Pv ) = P + W
Approximate area of the footing ( Area approx ) = P / Q
max

778.00
39.00
817.00

fdn

6.81

all

Keeping equal projection on either side of column,


Projection
Approx length of footing
Approx Width of footing
Area Provided

1131
2712
2512

Say
Say

2800
2600
7.28

Calculation of Actual size & pressure of the footing


Thickness of footing at column face ( OverAll col ) mm
Unit weight of Concrete ( c ) = 25 kN/cub. m
Footings

10

Dimension of the column along X-Direction (BCol x )


Dimension of the column along Y-Direction (BCol y )
Depth of Foundation from soil surface (Fdndepth )
Unit weight of soil ( s ) = 17.615 kN/cub. m
Pressure on foundation ( Pr dlw ) kN/sq.m

450.00
250.00
1800.00
106.87

Q All > Q Max Hence OK.

Thickness of mat in Flexure Case:


Projection on either side of Column
Maximum upward soil pressure under the foundation(Pr
Max Moment on foundation at column face( Mx design )

Design

1175.00
106.87

) kN/sq.m

Prdesign* ((Bx- BColx)*Bx / 2) 2 = kNm per m length


Characteristic strength of concrete (f ck ) =
N/sq.mm
Yeild strength of reinforcing steel (f y ) =
N/sq.mm
Overall thickness of the foundation at the face (OverAll edge ) mm
Clear cover to the outermost reinforcement bar (CL Foot ) mm
Dia of bottom reinforcement in X-direction ( x ) mm
Dia of bottom reinforcement in Y-direction ( y ) mm
Reqd thickness of the footing at column face in X-direction (Tcol x )

Overall thickness of the footing-- Assumed


Effective thickness of the footing at column face in

206.56
20
415
200.00
60.00
12.00
12.00
273.57

600.00

X-direction (Tcol x ) mm

Limiting MU/BD of the footing section =


2

534.00

2.76 N/sq.mm

Calculated MU/BD 2 in X direction = 0.387 N/sq.mm


Calculated MU/BD 2 in X direction < Limiting MU/BD 2 Hence OK.

0.72

Thickness of mat in One Way Shear Case:


Critical section lies at a distance of 'd' from face of column.
Depth at critical section
Upward shear force on footing at the critical section parallel to Y-axis (SF x )

352.00

kN
191.81

( ) N/sq.mm

Shear stress at the critical section parallel to Y-axis

vx

0.21

Maximum permissible shear stress of concrete ( ) for M 20 = 2.800 N/sq.mm


Design shear strength for 0.25% steel ( Tc)
0.36 N/sq.mm
cmax

OK

Punching Shear Calculation


Ratio of minimum to maximum dimension of column ( )
c

Footings

0.56
11

Value of K
Critical section lies at a distance of 'd/2' from face of column.
Minimum thickness of footing at critical section of punching shear (D Punch )
Perimeter of the punching shear zone (Peri Punch ) = 4512.000 mm
Area of the punching shear zone (AreaPunch ) = 1261148.000 sq. mm
Shear force for punching (SF punch ) = Pr * (B * B - Area ) kN

1.00

design

443.00
3536.00
0.77
695.56

Punch

Actual punching shear stress ( ) = SF / (Peri * D ) N/sq.mm


Allowable punching shear stress (
) = K * 0.25 * SQRT(f ) N/sq.mm

> Hence OK.


vPunch

punch

AllPunch

Punch

0.44

Punch

5.00

ck

AllPunch

vPunch

Area of Steel
Required Area of steel reinforcement in X-direction at bottom
(AstBottom x ) sq. mm per m length
Required Spacing of the bottom reinforcement along X-direction (Sp x )

1121.00 Sqmm/m
100 mm

Minimum allowable bar spacing (Sp min ) = 40.000 mm


Maximum allowable bar spacing (Sp max ) = 300.000 mm

Development Length Calculation


Permissible tensile stress of steel ( ) = 230.000 N
Design bond stress ( ) = 1.200 N
Allowable development length along X-direction
(LdevAllx ) = sst* f x/ (4.0 * tbd) = 575.000 mm
Allowable development length along Y-direction
(LdevAlly ) = sst* f y/ (4.0 * tbd) = 575.000 mm
Actual development length along X-direction
(LdevActx ) = 0.5 * (Bx- BColx) - 50 cover

230.00

st

1.20

bd

575.00
575.00
1125.00

LdevActx > LdevAllx Hence OK.


Design Summary:
Length
Width
Depth at Col face
Depth at Edge

Reinf

12

Footings

2800.00
2600.00
600.00
200.00
dia @ 100 mm

centres both ways

12

Footing- F5
For Columns- 76, 83

Geometry Data
Item
Col. Length( X-dirn)
Col. Width (Y-dirn)
Ratio (Length/Width)
Thickness at Edge
Thickness at ColFace
Depth of Foundation
Depth of Footing (Assume)

Value

Unit

0.4
0.3
1.3333333333
0.2
0.85
1.6
750

m
m
m
m
m
mm

Load Data
Item

Value

Unit
777 kN

Factored Axial
Materials Data
Item
Bearing Capacity of Soil
Unit Wt. of Soil
Grade of Concrete
Grade of Steel
Unit Wt. of Conc.

Value

Unit
250 kN/m2
1800 kg/m3
M20
Fe 415
2500 kg/m3

Reinforcement Data
Item
Dia of bar at bot.along X (mm)
Dia of bar at bot.along Y (mm)
Min. Bar Spacing
Max. Bar Spacing
Clear Cover

Value

Unit
12
12
0.04 m
0.3 m
0.06 m

113
113

Approximate Footing Size Calculations


Total maximum vertical load ( P max )
Approx weight of Foundation ( W fdn ) [5 percent of P max ,assumed]
Total Vertical Load ( Pv ) = P + W
Approximate area of the footing ( Area approx ) = P / Q
max

777.00
39.00
816.00

fdn

3.26

all

Keeping equal projection on either side of column,


Projection
Approx length of footing
Approx Width of footing
Area Provided

728
1856
1756

Say
Say

1900
1800
3.42

Calculation of Actual size & pressure of the footing


Thickness of footing at column face ( OverAll col ) mm
Unit weight of Concrete ( c ) = 25 kN/cub. m
Footings

13

Dimension of the column along X-Direction (BCol x )


Dimension of the column along Y-Direction (BCol y )
Depth of Foundation from soil surface (Fdndepth )
Unit weight of soil ( s ) = 17.615 kN/cub. m
Pressure on foundation ( Pr dlw ) kN/sq.m

400.00
300.00
1600.00
227.19

Q All > Q Max Hence OK.

Thickness of mat in Flexure Case:


Projection on either side of Column
Maximum upward soil pressure under the foundation(Pr
Max Moment on foundation at column face( Mx design )

Design

750.00
227.19

) kN/sq.m

Prdesign* ((Bx- BColx)*Bx / 2) 2 = kNm per m length


Characteristic strength of concrete (f ck ) =
N/sq.mm
Yeild strength of reinforcing steel (f y ) =
N/sq.mm
Overall thickness of the foundation at the face (OverAll edge ) mm
Clear cover to the outermost reinforcement bar (CL Foot ) mm
Dia of bottom reinforcement in X-direction ( x ) mm
Dia of bottom reinforcement in Y-direction ( y ) mm
Reqd thickness of the footing at column face in X-direction (Tcol x )

Overall thickness of the footing-- Assumed


Effective thickness of the footing at column face in

121.41
20
415
200.00
60.00
12.00
12.00
209.73

750.00

X-direction (Tcol x ) mm

Limiting MU/BD of the footing section =


2

684.00

2.76 N/sq.mm

Calculated MU/BD 2 in X direction = 0.387 N/sq.mm


Calculated MU/BD 2 in X direction < Limiting MU/BD 2 Hence OK.

0.26

Thickness of mat in One Way Shear Case:


Critical section lies at a distance of 'd' from face of column.
Depth at critical section
Upward shear force on footing at the critical section parallel to Y-axis (SF x )

182.00

kN
28.49

( ) N/sq.mm

Shear stress at the critical section parallel to Y-axis

vx

0.09

Maximum permissible shear stress of concrete ( ) for M 20 = 2.800 N/sq.mm


Design shear strength for 0.25% steel ( Tc)
0.36 N/sq.mm
cmax

OK

Punching Shear Calculation


Ratio of minimum to maximum dimension of column ( )
c

Footings

0.75
14

Value of K
Critical section lies at a distance of 'd/2' from face of column.
Minimum thickness of footing at critical section of punching shear (D Punch )
Perimeter of the punching shear zone (Peri Punch ) = 4512.000 mm
Area of the punching shear zone (AreaPunch ) = 1261148.000 sq. mm
Shear force for punching (SF punch ) = Pr * (B * B - Area ) kN

1.00

design

433.00
4136.00
1.07
534.66

Punch

Actual punching shear stress ( ) = SF / (Peri * D ) N/sq.mm


Allowable punching shear stress (
) = K * 0.25 * SQRT(f ) N/sq.mm

> Hence OK.


vPunch

punch

AllPunch

Punch

0.30

Punch

5.00

ck

AllPunch

vPunch

Area of Steel
Required Area of steel reinforcement in X-direction at bottom
(AstBottom x ) sq. mm per m length
Required Spacing of the bottom reinforcement along X-direction (Sp x )

499.00 Sqmm/m
225 mm

Minimum allowable bar spacing (Sp min ) = 40.000 mm


Maximum allowable bar spacing (Sp max ) = 300.000 mm

Development Length Calculation


Permissible tensile stress of steel ( ) = 230.000 N
Design bond stress ( ) = 1.200 N
Allowable development length along X-direction
(LdevAllx ) = sst* f x/ (4.0 * tbd) = 575.000 mm
Allowable development length along Y-direction
(LdevAlly ) = sst* f y/ (4.0 * tbd) = 575.000 mm
Actual development length along X-direction
(LdevActx ) = 0.5 * (Bx- BColx) - 50 cover

230.00

st

1.20

bd

575.00
575.00
700.00

LdevActx > LdevAllx Hence OK.


Design Summary:
Length
Width
Depth at Col face
Depth at Edge

Reinf

12

Footings

1900.00
1800.00
750.00
200.00
dia @ 225 mm

centres both ways

15

DESIGN OF STAIRCASE
Data
All Dimensions in mm & Loads in Kn
Tread
Rise
No of Treads
Width of Mid landing
Width of End landing
Width of Flight
Type of Building
R for Resdl, P for Public
Thickness of Waist Slab (Assume)
Design Constants:
Grade of Concrete
Grade of Steel

250
150
9
1600
1600
1500
R
180
20
415

Loads per Sqm:


i) On Flight
Dead Load
Wt. of Slab
Wt on Plan
Wt. of Step
Finish
Hand rail (LS)
Total
Live Load
Factored Load
ii) On Landing
Wt. of Slab
Finish
Hand rail (LS)
Live Load
Factored Load
Effective Length
Reactions :

4.5
5.25
1.88
0.6
0.5
8.23
3.00
11.23
16.85 KN
4.50
0.60
0.50
5.60
0.00
5.60
8.40 KN
5450

Rb

32.39625 KN

Ra

32.39625 KN

Distance of point where SF=0 from Right


Support

2725

Max BM

51.74 KNm

Depth required
Overall depth
Say
Hence Eff. Depth
Reinforcement:
Area of Tension Steel
Spacing of 12 dia bar
Distribution bars @ 0.12%
Spacing of 10 dia bar

136.92
157.92
160
139
1274 mm2
85 mm
192
405

Loads distributed on the supporting beams

91.7

91.69625

Table-1. Limiting Values of Moment of Resistance (ckbd2)

Grade of
Concrete

Fe 250

Fe 415

Fe 500

General

0.148

0.138

0.133

* p-106 AK Jain

Table-2. Limiting % of Tensile Steel


Grade of
Concrete
ck

Fe 250

Fe 415

Fe 500

M 15

1.32

0.72

0.57

M 20

1.76

0.96

0.76

M 25

2.2

1.19

0.94

M 30

2.64

1.43

1.13

* p-107 AK Jain

Table-3. Minimum % of Tensile Steel


Grade of
Concrete
ck

Fe 250

Fe 415

Fe 500

General

0.340%

0.205%

0.170%

* Cl 25.5.1.1 of Code

Table-2. Reinf % in Singly Reinforced Sections


Mu
bd2

p%
M 15

M 20

0.10
0.15
0.20
0.25
0.30
0.35
0.40
0.45
0.50
0.55
0.60
0.65
0.70
0.75
0.80
0.85
0.90
0.95
1.00
1.05
1.10
1.15
1.20
1.25
1.30
1.35
1.40
1.45
1.50
1.55
1.60
1.65
1.70
1.75
1.80
1.85
1.90
1.95
2.00

0.028
0.042
0.056
0.071
0.085
0.100
0.114
0.129
0.144
0.159
0.175
0.190
0.206
0.221
0.237
0.253
0.269
0.286
0.302
0.319
0.336
0.353
0.371
0.388
0.406
0.424
0.442
0.460
0.479
0.498
0.517
0.537
0.557
0.577
0.598
0.618
0.640
0.661
0.683

0.037
0.056
0.075
0.094
0.114
0.133
0.153
0.172
0.192
0.213
0.233
0.253
0.274
0.295
0.316
0.338
0.359
0.381
0.403
0.426
0.448
0.471
0.494
0.517
0.541
0.565
0.589
0.614
0.639
0.664
0.690
0.716
0.743
0.769
0.797
0.825
0.853
0.882
0.911

* p% = (0.5*fck/fe)*[1-SQRT{1-(4.6*Mu/bd 2)/fck}]*100
** Figs in Red indicate p% less than plim

Das könnte Ihnen auch gefallen