ELECTRICAL SYSTEM

Advanced FHDB
TRAINING

EMBRAER 170/190 Technical Support

September 2009

Electrical Systems Team (EFTC)


170electrical@embraer.com.br

FOR TRAINING PURPOSE ONLY. MATERIAL NOT CONTROLLED FOR UPDATES REVISIONS
REVISIONS

ELECTRICAL SYSTEM Advanced Training


RECORD OF REVISIONS
The user must update the Record of Revisions when a revision is put into the presentation

REV N

REV DATA

BY

02

09/03/2009

Cludio

REV N

REV DATA

BY

ELECTRICAL SYSTEM Advanced Training


RAM AIR TURBINE - RAT
RAT FAIL message being caused by incorrect power-up procedure.
RAT FAIL with BATT 1-2 OFF at the same time as IRS ALIGNING.


Incorrect power up with BATT 1 and 2 switches in OFF position, may affect the RAT System PBIT
causing RAT FAIL

Additional information, refer to SNL 170-24-0020/190-24-0014

S ta te

D a te /T im e

ACTIVE
ACTIVE
ACTIVE

01/06/08 2:53:03
01/06/08 2:53:03
01/06/08 2:53:03

A b s o lu te
F lig h t L e g

F lig h t P h a s e
Nam e

37 PREFLIGHT
37 PREFLIGHT
37 PREFLIGHT

FDE Nam e

BATT 1-2 OFF


IRS ALIGNING
RAT FAIL

F D E S e v e r ity

M a in t M s g N a m e

M a in t M s g C o d e

WARNING
ADVISORY
CAUTION

RAT FAIL during power up in conjunction with REMOTE CB TRIP:




RAT PBIT does not run if the SSPC RAT TEST and/or RAT HEATER are set to the OUT

RAT FAIL will be latched until a successful PBIT is accomplished (requires a new power-up).

Additional information, refer to SNL 170-24-0020/190-24-0014

FOR TRAINING PURPOSE ONLY. MATERIAL NOT CONTROLLED FOR UPDATES REVISIONS
REVISIONS

ELECTRICAL SYSTEM Advanced Training

RAM AIR TURBINE RAT (cont.)


RAT FAIL due to incorrect power-down with GND SVC BUS energized
 During the power-down procedure, the correct sequence is:
Set the GPU pushbutton on the electrical control panel to the unlatched position
Set both Batteries switches to OFF
 This procedure assures that the whole system is completely de-energized
 If the GROUND SERVICE pushbutton on the AC GPU panel (external AC power receptacle or forward
RH monument) is set to the latched position (IN USE lamp is on) before setting the batteries switches
to OFF, the ground service bus will be energized and the SPDA will keep energized. This does not
reset the whole system, thus avoiding a new RAT PBIT when the Batteries and GPU switches are set to
ON again
 It is necessary to accomplish the complete aircraft power-down procedure to allow the SPDA to run a
new RAT PBIT
 Additional information, refer to SNL 170-24-0020/190-24-0014

FOR TRAINING PURPOSE ONLY. MATERIAL NOT CONTROLLED FOR UPDATES REVISIONS
REVISIONS

ELECTRICAL SYSTEM Advanced Training

RAM AIR TURBINE RAT (cont.)


RAT FAIL due to Electrical Power Transient
 In case an electric power source is removed from the EPGDS before the necessary time for NBPT
completion, a power interruption may occurs on the aircraft
Additional information, refer to SNL 170-24-0029/190-24-0023
 If this power interruption affects the AC GND SVC bus, the RAT FAIL message will be displayed due to
RAT heater that is fed by this bus
State

Absolute
Flight Leg
8/31/2008 0:02:11
658
8/31/2008 0:02:11
658
Date/Time

INACTIVE
INHIBITED

Flight Phase
Name
PREFLIGHT
PREFLIGHT

FDE Name
SLAT LO RATE
RAT FAIL

FDE Severity

Maint Msg Name

Maint Msg
Code

Maint Msg
Type

ADVISORY
CAUTION

 SLAT LO RATE due to SF-ACE 1 SLAT CH 1 AC FEED and RAT FAIL due to RAT heater that uses
power from the AC GND SVC BUS.
 Additional information, refer to SNL 170-24-0031/190-24-0025

FOR TRAINING PURPOSE ONLY. MATERIAL NOT CONTROLLED FOR UPDATES REVISIONS
REVISIONS

ELECTRICAL SYSTEM Advanced Training


EPGDS Electrical Power Generating and Distribution System
NORMAL OPERATION

FOR TRAINING PURPOSE ONLY. MATERIAL NOT CONTROLLED FOR UPDATES REVISIONS
REVISIONS

ELECTRICAL SYSTEM Advanced Training

RAM AIR TURBINE RAT (cont.)


RAT FAIL without correlation occurring during aircraft power-up
 In the majority of the events a subsequent PD/PU clears the message
 When repetitive events are notice, we usually recommends the following T/S (based on FIM TASK 2423-00-810-806A)
RLC
EICC K5 (1S DELAY RELAY)
EICC K6 (TRUEC)
Wiring check (insulation and continuity) - WM 24-23-50 and 24-31-52
K0063
RAT heater element (at RAT) (connector J6CX pins E and F) using a ohmmeter.
 The resistance value shall be around 97 ohms. In case an open is found, it indicates an
RAT heater issue and the RAT shall be replaced.

ELECTRICAL SYSTEM Advanced Training

RAM AIR TURBINE RAT (cont.)


RAT FAIL without correlation occurring during aircraft power-up (cont.)
 There are some investigations on going specially focusing in aircraft data for uncorrelated faults
(ASCB), RAT PBIT concerning timing, and RLC auxiliary contacts
 So far, shop findings of at least 9 contactors (RLC position) are showing the root cause as DROP
VOLTAGE on contacts 12/13 that are link for K5 command (Investigation on going)

ELECTRICAL SYSTEM Advanced Training

INTEGRATED DRIVE GENERATOR - IDG


IDG 1 (2) OFF BUS during engine start
 IDG 1 (2) OFF BUS CAS caution message that appears during the engine start and extinguishes after
a few seconds. As the message appears and extinguishes even before the GLC closing, such behavior
does not indicate a real system failure
 Additional information, refer to SNL 170-24-0018/190-24-0012
IDG 1 (2) OFF BUS in conjunction with ENG 1 (2) TLA NOT IN IDLE CAS
 During the engine shutdown procedure, the correct throttle lever position is IDLE. When the throttle
lever is not in the IDLE position and ENG 1 (2) START/STOP switch has been set to the STOP position,
the respective Generator Control Unit (GCU) senses through the engine rotation that IDG 1 (2) would
still be the primary power source. Then, the IDG 1 (2) OFF BUS CAS message is triggered
 Additional information, refer to SNL 170-24-0018/190-24-0012

State

ACTIVE
ACTIVE
INACTIVE
INACTIVE

Date/Time

02/09/08 0:52:43
02/09/08 0:52:48
02/09/08 0:52:54
02/09/08 0:52:57

Absolute
Flight Leg

Flight Phase
Name

42 TAXI
42 TAXI
42 TAXI
42 TAXI

FDE Name

ENG 2 TLA NOT IDLE


IDG 2 OFF BUS
ENG 2 TLA NOT IDLE
IDG 2 OFF BUS

FDE Severity

Maint Msg Name

STATUS
CAUTION
STATUS
CAUTION

FOR TRAINING PURPOSE ONLY. MATERIAL NOT CONTROLLED FOR UPDATES REVISIONS
REVISIONS

Maint Msg Code

ELECTRICAL SYSTEM Advanced Training


SPDA SECONDARY POWER DISTRIBUTION ASSEMBLY
SPDA FAIL correlated to Power Supply SPDA1 LRM 1 (20) FAULT or SPDA2 LRM1 (26) FAULT
 In each SPDA chassis, there are two microprocessors (MICRO/COMM) that operate in an
active/standby mode and two power supplies modules that are isolated from each other
 Power Supply module 1 (SPDA 1 LRM1 / SPDA2 LRM1) provides power to MICRO/COMM 1 (SPDA 1
LRM8 / SPDA 2 LRM8) respectively
 Power Supply module 2 (SPDA 1 LRM20 / SPDA2 LRM26) provides power to MICRO/COMM 2 (SPDA 1
LRM12 / SPDA 2 LRM12) respectively
 Each MICRO/COMM has an independent communications bus to the I/O modules
 The SPDA can fully perform with a single power supply and the respective microprocessor operative
Board LED is ON when operational (except MICRO/COMM, one will be ON while the other will be
OFF)
 When the SPDA FAIL message is correlated to a power supply module, the MICRO/COMM will show at
the same time. This scenario occurs because each MICRO/COMM is powered by only one power
supply. In case this power supply fails, the MICRO/COMM will fails too
State
ACTIVE
ACTIVE

Date/Time
Absolute Flight Leg Flight Phase Name
12/8/2006 17:02:19
22
PREFLIGHT
12/8/2006 17:02:19
22
PREFLIGHT

FDE Name
SPDA FAIL
SPDA FAIL

FDE Severity
ADVISORY
ADVISORY

Maint Msg Name


SPDA2 LRM1 FAULT
SPDA2 LRM8 FAULT

FOR TRAINING PURPOSE ONLY. MATERIAL NOT CONTROLLED FOR UPDATES REVISIONS
REVISIONS

Maint Msg Code


24610001SP2
24610016SP2

ELECTRICAL SYSTEM Advanced Training


SPDA 1 POWER FEED SCHEMATIC

FOR TRAINING PURPOSE ONLY. MATERIAL NOT CONTROLLED FOR UPDATES REVISIONS
REVISIONS

ELECTRICAL SYSTEM Advanced Training


SPDA 2 POWER FEED SCHEMATIC

FOR TRAINING PURPOSE ONLY. MATERIAL NOT CONTROLLED FOR UPDATES REVISIONS
REVISIONS

ELECTRICAL SYSTEM Advanced Training


SPDA SECONDARY POWER DISTRIBUTION ASSEMBLY
SPDA FAIL correlated to SPDA 2 FAULT
 Loss of SPDA#2 communication with ASCB BUS
 The SPDA1 LRM8 (STANDBY) FAULT maintenance message indicates that the standby or active
MICRO/COMM failed to communicate with the ASCB. The opposite SPDA sends a fault report to the
CMC. The CAN bus is used to transmit the fault information between SPDAs
 As a consequence FUEL FEED 1 FAULT and APU FUEL SOV CLOSED are also displayed in Cruise due
to system default

State

ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE

Date/Time

8/25/2009
8/25/2009
8/25/2009
8/25/2009
8/25/2009
8/25/2009
8/25/2009
8/25/2009
8/25/2009
8/25/2009
8/25/2009
8/25/2009
8/25/2009

9:38:41
9:38:41
9:38:42
9:38:46
9:38:50
9:38:50
9:38:50
9:38:51
9:38:52
9:38:58
9:39:02
9:39:07
9:39:10

Absolute
Flight Leg

Flight
Phase
Name

1163
1163
1163
1163
1163
1163
1163
1163
1163
1163
1163
1163
1163

CRUISE
CRUISE
CRUISE
CRUISE
CRUISE
CRUISE
CRUISE
CRUISE
CRUISE
CRUISE
CRUISE
CRUISE
CRUISE

FDE Name

SPDA FAIL
SPDA FAIL
FUEL FEED 1 FAULT
SPDA FAIL
SPDA FAIL
SPDA FAIL
SPDA FAIL
APU FUEL SOV CLOSED
FUEL FEED 1 FAULT
FUEL FEED 1 FAULT
FUEL FEED 1 FAULT
FUEL FEED 1 FAULT
FUEL FEED 1 FAULT

FDE Severity

ADVISORY
ADVISORY
ADVISORY
ADVISORY
ADVISORY
ADVISORY
ADVISORY
STATUS
ADVISORY
ADVISORY
ADVISORY
ADVISORY
ADVISORY

M aint M sg Name

M aint M sg
Code

M aint M sg Type

SPDA2 FAULT

45452091CMC

Interface

SPDA2 LRM8 (STANDBY MICRO) FAULT

24610046SP1

Internal Hardware

SPDA2 LRM8 (STANDBY MICRO) FAULT


SPDA2 FAULT

24610046SP1
45452091CMC

Internal Hardware
Interface

ELECTRICAL SYSTEM Advanced Training


SPDA SECONDARY POWER DISTRIBUTION ASSEMBLY
SPDA FAIL correlated to SPDA 2 FAULT (cont.)
 During ROLL OUT and TAXI flight phases, ENG 1 NO DISPATCH, ENG 2 NO DISPATCH and CRG FIRE
PROT FAULT usually are also displayed
 The SPDA2 LRM10/LRM12/LRM8 FAULT maintenance message indicates that the standby or active
MICRO/COMM failed to communicate with the ASCB. The opposite SPDA sends a fault report to the
CMC. The CAN bus is used to transmit the fault information between SPDAs
NOTE: DO NOT FORGET TO UPLOAD THE APPLICATION SOFTWARE AFTER INSTALLATION OF A SPDA
MICRO/COMM OR ASCB MODULE. THE EASIEST WAY TO DO THAT IS TROUGH A TARGET LOAD ON
THE RELATED SPDA
S ta te

A C T IV E
A C T IV E
A C T IV E
A C T IV E
A C T IV E
A C T IV E
A C T IV E
A C T IV E
A C T IV E
A C T IV E
A C T IV E
A C T IV E
A C T IV E
A C T IV E
A C T IV E

D a te/T im e

8 /2 5 /2 0 0 9
8 /2 5 /2 0 0 9
8 /2 5 /2 0 0 9
8 /2 5 /2 0 0 9
8 /2 5 /2 0 0 9
8 /2 5 /2 0 0 9
8 /2 5 /2 0 0 9
8 /2 5 /2 0 0 9
8 /2 5 /2 0 0 9
8 /2 5 /2 0 0 9
8 /2 5 /2 0 0 9
8 /2 5 /2 0 0 9
8 /2 5 /2 0 0 9
8 /2 5 /2 0 0 9
8 /2 5 /2 0 0 9

1 0 :4 7:5 1
1 0 :4 7:5 1
1 0 :4 7:5 4
1 0 :4 7:5 4
1 0 :4 7:5 4
1 0 :4 7:5 5
1 0 :4 8:2 6
1 0 :4 8:3 5
1 0 :4 8:3 8
1 0 :4 8:4 2
1 0 :4 8:4 6
1 0 :4 9:1 1
1 0 :4 9:2 3
1 0 :4 9:3 1
1 0 :4 9:3 5

Ab s o lu te
F lig h t L e g

F lig h t
P h a se
N am e

1 1 63
1 1 63
1 1 63
1 1 63
1 1 63
1 1 63
1 1 63
1 1 63
1 1 63
1 1 63
1 1 63
1 1 63
1 1 63
1 1 63
1 1 63

ROLL OUT
ROLL OUT
ROLL OUT
ROLL OUT
ROLL OUT
ROLL OUT
TAXI
TAXI
TAXI
TAXI
TAXI
TAXI
TAXI
TAXI
TAXI

F D E N am e

E N G 1 N O D IS P A T C H
E N G 2 N O D IS P A T C H
S P D A F AIL
S P D A F AIL
S P D A F AIL
AP U F U E L S O V C L O S E D
C R G F IR E P R O T F A U L T
C R G F IR E P R O T F A U L T
C R G F IR E P R O T F A U L T
C R G F IR E P R O T F A U L T
C R G F IR E P R O T F A U L T
C R G F IR E P R O T F A U L T
C R G F IR E P R O T F A U L T
C R G F IR E P R O T F A U L T
C R G F IR E P R O T F A U L T

F D E S e v e rity

C AU T IO N
C AU T IO N
A D V IS O R Y
A D V IS O R Y
A D V IS O R Y
STATU S
A D V IS O R Y
A D V IS O R Y
A D V IS O R Y
A D V IS O R Y
A D V IS O R Y
A D V IS O R Y
A D V IS O R Y
A D V IS O R Y
A D V IS O R Y

M a in t M s g N a m e

S P D A 2 L R M 1 0/L R M 1 2/L R M 8 F AU L T
S P D A 2 F AU L T

M a in t M s g
C ode

2 4 6 10 0 4 8 S P 1
4 5 4 52 0 9 1 C M C

M ain t M s g T yp e

In te rn a l H a rd w are
In te rfa ce

ELECTRICAL SYSTEM Advanced Training


SPDA SECONDARY POWER DISTRIBUTION ASSEMBLY
Maintenance Message SPDA2 LRM7 FAULT
 In case the CMC message SPDA2 LRM7 FAULT is ACTIVE on the CMC do the following procedure:
Get access to the OPTIONS CB/SSPC page according to AMM TASK 24-60-00-910-801-A (CB
MENU Screen - MCDU Operation)
Change the configuration (Enable/Disable) for LAV LT AFT2 GSVC SSPC
Check if the CMC message SPDA2 LRM7 FAULT goes to INACTIVE
 In case CMC message goes to INACTIVE, keep the SSPC in the selected configuration
 In case the CMC message stays ACTIVE, change the SSPC configuration according to
aircraft configuration and follow the FIM procedure TASK 24-61-00-810-807-A
 In case the message does not extinguish even after a module swap, and it is not affecting any system,
it is considered spurious
 The scenario described above have shown only in the EMBRAER 190/195 and it is under investigation
 Additional information, refer to SNL 190-24-0033

FOR TRAINING PURPOSE ONLY. MATERIAL NOT CONTROLLED FOR UPDATES REVISIONS
REVISIONS

ELECTRICAL SYSTEM Advanced Training


SPDA BLOCK EVOLUTION SCHEMATIC

ELECTRICAL SYSTEM Advanced Training


SPDA SECONDARY POWER DISTRIBUTION ASSEMBLY
SPDA MICRO/COMM BORDS CONFIGURATION AFTER REPLACEMENT

ELECTRICAL SYSTEM Advanced Training


GSTC Ground Service Transfer Contactor
TRU 1 FAIL, FWD EBAY FANS FAIL and CENTER EBAY FANS FAIL in the same event
 When TRU 1 FAIL is displayed correlated to TRU1 (RIPPLE)/GCU1/WRG FAULT or TRU1 (FEEDER)
[AGCU]/WRG FAULT it may indicate an electrical input power problem
 There were some cases in which the TRU 1 FAIL occurred due to loss of one of the AC phases coming
from the GSTC
 CENTER and FWD E-bay fans being fed by only two phases may cause their CB to open (REMOTE CB
TRIP CAS message is a clue to indicate this condition)
 In case C is the affected phase, the RAT FAIL will be also displayed due to RAT HEATER that is fed
by AC GND SVC bus

State

ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE

Date/Time

8/13/2008 14:30:43
8/13/2008 14:30:43
8/13/2008 14:30:43
8/13/2008 14:30:43
8/13/2008 14:30:43
8/13/2008 14:30:43
8/13/2008 14:30:43

Absolute
Flight Leg
32
32
32
32
32
32
32

Flight Phase
Name
PREFLIGHT
PREFLIGHT
PREFLIGHT
PREFLIGHT
PREFLIGHT
PREFLIGHT
PREFLIGHT

FDE Name

IRS ALIGNING
>CENTER EBAY FANS FAIL
>FWD EBAY FANS FAIL
RAT FAIL
TRU 1 FAIL
TRU 1 FAIL
REMOTE CB TRIP

FDE Severity

ADVISORY
CAUTION
CAUTION
CAUTION
CAUTION
CAUTION
ADVISORY

Maint Msg Name

TRU1 (FEEDER) [AGCU]/WRG FAULT

FOR TRAINING PURPOSE ONLY. MATERIAL NOT CONTROLLED FOR UPDATES REVISIONS
REVISIONS

Maint Msg
Code

Maint Msg
Type

24310030AGC Interface

ELECTRICAL SYSTEM Advanced Training


GSTC Ground
Service Transfer
Contactor (cont.)
AC GND SVC Load
Distribution
NOSE LANDING LIGHT
operational test is an
optional way to verify
GSTC phase C once
this light is also
supplied by AC GND
SERVICE Bus phase C

LOAD IDENTIFICATION

PHASE

CB LOCATION

ATA

BUS

FAN 1 FWD BAY

PHA

LICC_G

21

AC GND SVC

FAN 1 FWD BAY

PHB

LICC_G

21

AC GND SVC

FAN 1 FWD BAY

PHC

LICC_G

21

AC GND SVC

FAN 1 MID BAY

PHA

LICC_G

21

AC GND SVC

FAN 1 MID BAY

PHB

LICC_G

21

AC GND SVC

FAN 1 MID BAY

PHC

LICC_G

21

AC GND SVC

RAT HEATER

PHC

SPDA1_16

24

AC GND SVC

AC OUTLET PWR1 -

PHA

LICC_G

25

AC GND SVC

AC OUTLET PWR2 -

PHB

LICC_G

25

AC GND SVC

GALLEY G1 / G3 HOT JUG

PHB

SPDA1_16

25

AC GND SVC

CEILING LIGHTS

PHA

LICC_G

33

AC GND SVC

CEILING LIGHTS

PHB

LICC_G

33

AC GND SVC

CEILING LIGHTS

PHC

LICC_G

33

AC GND SVC

NOSE LANDING LIGHT

PHC

SPDA1_16

33

AC GND SVC

NOSE TAXI LIGHT

PHA

SPDA1_16

33

AC GND SVC

SIDEWALL LIGHTS

PHA

LICC_G

33

AC GND SVC

SIDEWALL LIGHTS

PHB

LICC_G

33

AC GND SVC

SIDEWALL LIGHTS

PHC

LICC_G

33

AC GND SVC

DRAIN MAST AFT

PHB

SPDA1_16

38

AC GND SVC

DRAIN MAST FWD

PHA

SPDA1_16

38

AC GND SVC

FILL/DRAIN NIPPLE HEATER -

PHC

LICC_G

38

AC GND SVC

HEATER WASTE SVC PNL RINSE NIPPLE -

PHA

LICC_G

38

AC GND SVC

HEATER WASTE SVC PNL VALVE -

PHC

LICC_G

38

AC GND SVC

VACUUM MOTOR GEN

PHA

LICC_G

38

AC GND SVC

VACUUM MOTOR GEN

PHB

LICC_G

38

AC GND SVC

VACUUM MOTOR GEN

PHC

LICC_G

38

AC GND SVC

WATER HEATER FWD LAV -

PHA

LICC_G

38

AC GND SVC

ELECTRICAL SYSTEM Advanced Training


AETC AC Essential Transfer Contactor or RLC Rat Line Contactor
FLAP LO RATE, FUEL AC PUMP 2 FAIL, FWD/CENTER EBAY FANS FAIL, REMOTE CB TRIP and AC ESS BUS
OFF in the same event
 The common root cause for this scenario is usually AETC or RLC
 CENTER and FWD E-bay fans being fed by only two phases may cause their CB to open (REMOTE CB
TRIP CAS message is a clue to indicate this condition)
State
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
INHIBITED
INHIBITED

Date/Time
8/11/2009 15:10:24
8/11/2009 15:10:25
8/11/2009 15:10:25
8/11/2009 15:10:57
8/11/2009 15:10:57
8/11/2009 15:31:19
8/11/2009 15:32:58
8/11/2009 15:32:58

Absolute Flight Leg Flight Phase Name


384
384
384
384
384
384
384
384

PREFLIGHT
PREFLIGHT
PREFLIGHT
PREFLIGHT
PREFLIGHT
PREFLIGHT
PREFLIGHT
PREFLIGHT

FDE Name
FLAP LO RATE
FUEL AC PUMP 2 FAIL
FUEL AC PUMP 2 FAIL
>AC ESS BUS OFF
>AC ESS BUS OFF
REMOTE CB TRIP
>CENTER EBAY FANS FAIL
>FWD EBAY FANS FAIL

FDE Severity
ADVISORY
CAUTION
CAUTION
CAUTION
CAUTION
ADVISORY
CAUTION
CAUTION

Maint Msg Name

AC PUMP2/PR SW/RLY/MAU3 GIO3/WRG


SPDA1 LRM 17/WRG FAULT
AETC/SPDA1 LRM7/WRG FAULT
AC ESS BUS OFF [CMC]
AC ESS BUS OFF [CMC]

FOR TRAINING PURPOSE ONLY. MATERIAL NOT CONTROLLED FOR UPDATES REVISIONS
REVISIONS

ELECTRICAL SYSTEM Advanced Training


AETC AC Essential
Transfer Contactor or
RLC Rat Line
Contactor

AC ESS BUS Load


Distribution

LOAD IDENTIFICATION

PHASE

CB LOCATION

ATA

BUS

FWD EMERGENCY FAN FEED

PHA

EICC

21

AC ESS BUS

FWD EMERGENCY FAN FEED

PHB

EICC

21

AC ESS BUS

FWD EMERGENCY FAN FEED

PHC

EICC

21

AC ESS BUS

MID EMERG FAN FEED

PHA

EICC

21

AC ESS BUS

MID EMERG FAN FEED

PHB

EICC

21

AC ESS BUS

MID EMERG FAN FEED

PHC

EICC

21

AC ESS BUS

STBYC CMD

PHB

EICC

24

AC ESS BUS

SFECU 1 FLAP CHANNEL 1 AC FEED -

PHA

EICC

27

AC ESS BUS

SFECU 1 FLAP CHANNEL 1 AC FEED -

PHB

EICC

27

AC ESS BUS

SFECU 1 FLAP CHANNEL 1 AC FEED -

PHC

EICC

27

AC ESS BUS

SFECU 2 SLAT CHANNEL 2 AC FEED -

PHA

EICC

27

AC ESS BUS

SFECU 2 SLAT CHANNEL 2 AC FEED -

PHB

EICC

27

AC ESS BUS

SFECU 2 SLAT CHANNEL 2 AC FEED -

PHC

EICC

27

AC ESS BUS

AC FUEL PUMP 2A

PHA

EICC

28

AC ESS BUS

AC FUEL PUMP 2A

PHB

EICC

28

AC ESS BUS

AC FUEL PUMP 2A

PHC

EICC

28

AC ESS BUS

HYDR MOTOR PUMP 3A

PHA

EICC

29

AC ESS BUS

HYDR MOTOR PUMP 3A

PHB

EICC

29

AC ESS BUS

HYDR MOTOR PUMP 3A

PHC

EICC

29

AC ESS BUS

ENG 1 EXCITER 1A

PHB

EICC_S

74

AC STDBY

ENG 2 EXCITER 2A

PHB

EICC_S

74

AC STDBY

ELECTRICAL SYSTEM Advanced Training

EICC K4
Maintenance Message AETC/SPDA1 LRM7/WRG FAULT
 This maintenance message indicates AETC position different from what is expected
 When AC BUS 2 is energized, the AETC is closed, connecting AC BUS 2 to AC ESS BUS
 In case the AC BUS 2 is energized but the AC ESS BUS is connected to AC BUS 1, the maintenance
message AETC/SPDA1 LRM7/WRG FAULT will be recorded in the CMC
No CAS message will indicate this condition
 This situation can also be identified by the Electric Synoptic Page view.
AMM requests the synoptic page check during power up procedure
 FIM TASK 24-51-00-810-813-A covers the fault isolation procedure
EICC K4 relay is usually the root cause
State
ACTIVE
ACTIVE
ACTIVE

Absolute
Flight
Flight
Phase
Leg
Name
11/28/2007 18:18:42
235
TAKE OFF
11/28/2007 20:54:09
236
TAKE OFF
11/29/2007 6:49:29
236
TAXI
Date/Time

FDE Name

FDE Severity

Maint Msg Name


AETC/SPDA1 LRM7/WRG FAULT
AETC/SPDA1 LRM7/WRG FAULT
AETC/SPDA1 LRM7/WRG FAULT

FOR TRAINING PURPOSE ONLY. MATERIAL NOT CONTROLLED FOR UPDATES REVISIONS
REVISIONS

Maint Msg
Code

Maint
Msg Type

24510001EP1 Interface
24510001EP1 Interface
24510001EP1 Interface

ELECTRICAL SYSTEM Advanced Training


ELECTRICAL SYSTEM SYNOPTIC PAGE

FOR TRAINING PURPOSE ONLY. MATERIAL NOT CONTROLLED FOR UPDATES REVISIONS
REVISIONS

ELECTRICAL SYSTEM Advanced Training

MAINTENANCE MESSAGES
Maintenance Message LICC CB MATRIX/GCU 1/WRG FAULT
 Indicates an disagreement between LICC TCB status and its monitoring (wrong TCB Indication on
MCDU)
 FIM TASK 24-21-00-810-824-A covers the fault isolation procedure
 Interference between large black harness nearby P1 connector and its connector
 Harnesses re-routing was implemented to provide an additional tolerance in terms of space
LICC PN 5914902-1 / 342GZ01Y00 is not affected by this issue
LICC PN 5914480-2 / 341GZ01Y01 S/N A292 and on have this improvement factory-incorporated
 This maintenance message can also be related to a faulty GCU or improper GCU installation

FOR TRAINING PURPOSE ONLY. MATERIAL NOT CONTROLLED FOR UPDATES REVISIONS
REVISIONS

ELECTRICAL SYSTEM Advanced Training


PICTURE OF P1 CONNECTOR

FOR TRAINING PURPOSE ONLY. MATERIAL NOT CONTROLLED FOR UPDATES REVISIONS
REVISIONS

ELECTRICAL SYSTEM Advanced Training


PICTURE OF P1 CONNECTOR

Broken
solder
point

FOR TRAINING PURPOSE ONLY. MATERIAL NOT CONTROLLED FOR UPDATES REVISIONS
REVISIONS

ELECTRICAL SYSTEM Advanced Training

LICC
 ACFT Not Accepting AC External Power
 LICC internal flat cable (ICA) connects AC external power to EPM
 It has been identified that this flat cable may be damaged due to the tracks capacity to be lower than
the interlock circuit pin E/F over current protection threshold, available on the EPM
 FIM TASK 24-42-00-810-817-A covers the fault isolation procedure
 The immediate solution to this issue is adding a jumper to the interlock trace to increase current
carrying capability, making it more robust
LICC PN 5914480-2 / 341GZ01Y01 S/N A0425 and on have the jumper modification factoryincorporated
LICC PN 5914902-1 / 342GZ01Y00 S/N B0186 and on have the jumper modification factoryincorporated
Modified units are identified with a mark in the MOD 6 (mod dot) on the identification plate
HS SB 40EPS04LC/LC2-24-6 was issued to incorporate this solution when a LICC returns to a
shop repair

ELECTRICAL SYSTEM Advanced Training