Sie sind auf Seite 1von 125

Welcome

2007, ZTE Corporation. All rights reserved


2007, ZTE Corporation. All rights reserved.

ZXMW PR10 V4 Technical Training


August 2007

2007, ZTE Corporation. All rights reserved.

Agenda

ZXMW PR10 V4 - Product Overview


Product abstract
Key Features & Benefits
Main Application

Specification
Released products / Future products

2007, ZTE Corporation. All rights reserved.

Agenda

HW Modules (IDU, ODU)

SW Modules
IDU SW
ODU SW

Management (Overview only)

Link Installation and Setup

2007, ZTE Corporation. All rights reserved.

ZXMW PR10 V4 Series - Overview


Our latest family of microwave digital radios, leads the market in technology
innovation, network flexibility and the global transformation to IP.
Versatile, compact split-mount digital radio delivering data and voice
connectivity for cellular backhaul, enterprise, government, and public safety
networks. It is optimized for efficient, flexible PDH-IP operation in nextgeneration wireless networks.
Supports all major frequency bands from 7 to 38 GHz and up to 32 E1 or
16xE1 telephony plus 4x10/100Base-T data interfaces. Using innovative,
high-performance modem technology, it supports QPSK and 16 QAM
modulation over a wide range of channel band-widths software selectable
from 3.5 to 28 MHz.
Provides low-to-medium capacity PDH access and transport. It is an easyto-deploy, easy-to-configure, and cost-effective microwave digital radio.

2007, ZTE Corporation. All rights reserved.

ZXMW PR10 V4 Series Key Features

ODU is independent of capacity


IDU is independent of RF
4 to 32 E1 (optional) network interfaces
4x10/ 100Base-T network interfaces
Fully programmable modem
In-service performance monitoring with parameters
compliant to ITU-T G.826 recommendations
Optional digital order wire
Built-in agent to support SNMP protocol
Programmable relay contacts for alarm indication / site
control
Site alarms monitoring
Web-CIT for radio maintenance
Local tributary loopback
TPC and ATPC operation

2007, ZTE Corporation. All rights reserved.

ZXMW PR10 V4 Series System Benefits


High system gain
Reed Solomon (Forward Error Correction)
Correct up to 16 Bytes from 252 Bytes frame (on each frame)

ASIC Technology - Digital Architecture


Complete Digital Design
ASIC - Digital Modem
Digital Multiplexer (Xilinx)

Flexible Interfaces - LAN, PDH


LAN or PDH
Easy to implement mixed modes

Scalable Capacity
Spectrum on Demand The availability to configure bandwidth to
support various modes of operations by software command.
System to offer scalable data rates by a unique
digital modem design - one IDU for all capacities
Data rates from E1 (2 Mbps) to 16 E1 (32 Mbps)
Reduced logistics, spare parts and product stocking
2007, ZTE Corporation. All rights reserved.

ZXMW PR10 V4 IDU Configuration


The IDU in an Unprotected Configuration houses the main
sections: Traffic Modulation Unit (TMU). It can also include
optional Ethernet Traffic Unit (Eth TU).

ZXMW PR10 V4 IDU 16E1 1+0

ZXMW PR10 V4 IDU 16E1+Eth 1+0

2007, ZTE Corporation. All rights reserved.

ZXMW PR10 V4 IDU Configuration


The IDU in a Protected Configuration houses the main sections:
Service Unit (SU), Core Unit (CU), E1 Traffic Unit (TU), Modem
Unit (MU). It can also include optional Ethernet Traffic Unit (Eth
TU). All modules compose the 1-RMS IDU.

ZXMW PR10 V4 IDU 16E1 1+1

ZXMW PR10 V4 IDU 16E1+Eth 1+1

2007, ZTE Corporation. All rights reserved.

ZXMW PR10 V4 ODU/Antenna Configuration


The ZXMW-PR10 V4 radio uses an ODU architecture suited for an
Outdoor/Indoor Separate mount. The ODU can also be mounted directly
to a special outdoor pole-mounted antenna, as a Detachable mount.
The following illustrations provide an overview of such configurations

ODU A1

ODU A2

Unprotected ODU

Protected ODU

2007, ZTE Corporation. All rights reserved.

ZXMW PR10 V4 Main Application

2G/3G Mobile Network Base Station Interconnection


2007, ZTE Corporation. All rights reserved.

ZXMW PR10 V4 Currently Frequency Plans,


Channel Spacing
Item
Frequency
Range [GHz]
Frequency
Plan
ITU-R/CEPT
Channel
Separation
RF TX/RX
Spacing
[MHz]

7GHz

8 GHz

13 GHz

15GHz

7.11-7.9

7.725-8.5

12.75-13.25

14.5-15.35

F.385-7
Annex 1
Annex 4
CEPT/ERC
REC 02-06

F.386-6
Annex 1
Annex 3
Annex 4

F.497-6
CEPT/ERC
REC12-02

F.636-3
CEPT/ERC
REC12-07

QPSK: 7MHz/4E1, 14MHz/8E1, 28MHz/16E1


16QAM: 3.5MHz/4E1, 7MHz/8E1, 14MHz/16E1, 28MHz/32E1
154,161,
168,196,245

119,126
305.56,311.32

266

420,490,728

2007, ZTE Corporation. All rights reserved.

ZXMW PR10 V4 Currently Frequency Plans,


Channel Spacing (Continued)
Item

18 GHz

23 GHz

26 GHz

38 GHz

Frequency
Range [GHz]

17.7-19.7

21.2-23.6

24.5-26.5

37.0-39.5

Frequency
Plan
ITU-R/CEPT

F.595-6
F.191
CEPT/ERC
REC12-03

F.637-3
CEPT/ERC REC
T/R 13-02
Annex A

F.748-3
CEPT/ERC
REC T/R 13-02
Annex B

F.749-1
CEPT/ERC
REC T/R 12-01

Channel
Separation
RF TX/RX
Spacing
[MHz]

QPSK: 7MHz/4E1, 14MHz/8E1, 28MHz/16E1


16QAM: 3.5MHz/4E1, 7MHz/8E1, 14MHz/16E1, 28MHz/32E1
1010

1008

1008

1260

2007, ZTE Corporation. All rights reserved.

ZXMW PR10 V4 Power Consumption

Configuration

1+0

1+1

30W (Rate Free)

45W (Rate free)

A1

35W

35W2

A2

24W

24W2

with ODU A1

55W

115W

with ODU A2

45W

99W

IDU
ODU
Power
Consumption(Max)

2007, ZTE Corporation. All rights reserved.

ZXMW PR10 V4 Nominal Transmit Power

Frequency(GHz)
Output Power
(dBm )

QPSK

13

15

18

23

26

38 Guaranteed

24.0 24.0 21.0 21.0 20.0 20.0 20.0 17.0

2.0 dB

16QAM 20.0 20.0 17.0 17.0 15.0 15.0 15.0 13.0

2007, ZTE Corporation. All rights reserved.

ZXMW PR10 V4 System Threshold Level

Frequency(GHz)
QPSK
BER = 10-6
16QAM

16E1
8E1
4E1
32E1
16E1
8E1
4E1

7
-82.5
-85.0
-88.0
-74.0
-80.5
-83.0
-85.0

8
-82.0
-84.5
-87.5
-74.0
-80.0
-82.5
-84.5

13
-82.0
-85.0
-87.5
-73.0
-80.0
-82.5
-85.0

15
-82.0
-85.0
-87.5
-73.0
-80.0
-82.5
-85.0

18
-87.0
-90.0
-92.5
-82.5
-86.0
-88.5
-91.0

23
-85.0
-88.0
-91.0
-80.5
-84.0
-86.5
-89.0

26
-85.5
-88.5
-91.5
-81.0
-84.5
-87.0
-89.5

38 Guaranteed
-85.0
-88.0
-91.0
+1.0 dB
-79.5
-83.0
-85.5
-88.0

2007, ZTE Corporation. All rights reserved.

ZXMW PR10 V4 System Characteristics


Item
Frequency(GHz)
Power Control
ATPC range
Frequency Stability
Configuration
Receiver Noise Figure
(at Ant. port) dB
M aximum Input Level
M etering Access
M odulation Type
Baseband Interface
NE1 (N=4/8/16/32)
NE1 (N=0/4/8/16)
+ 410/100 Base T(X)
Service Channels
Residual BER
ODU M onitor Items
EM C
M ean Time Between Failures
Guaranteed Temperature Range
Dimensions (mm) and Weight

4.5

4.5

System Characteristics
13 15 18 23 26 38
Guaranteed
20 dB, in 1 dB step
1.0 dB
20 dB, in 1 dB step
5 ppm
10 ppm
1+0, 1+1 (HS), 1+1 (HS/SD), 1+1 (FD)
+2 dB (13/15/18G)
4.5 4.5 5.5 6.5
7
7.5
+1.5 dB(23/38G)
-20 dBm (No Error)
RX Signal Level
QPSK or 16QAM

E1 (ITU-T G.703), 10/100 Base T(X) (IEEE 802.3)


G.703 (Co-directional) 64kbps1channel, Engineering Order
Less than 10^-12 at RSL = -30 dBm
Received signal level (AGC V),Output power level (TX PWR)
Conforms to ETSI 301 489-4
200,000Hours
IDU: -5 to 45C, ODU: -33 to +55C
ODU A1: 230 (W) 305 (H) 102 (D), 5.2 Kg
ODU A2: 210 (W) 290 (H) 90 (D), 5 Kg
IDU: 1+0, 482 (W) 44 (H) 240 (D), 3 kg
IDU: 1+1, 482 (W) 44 (H) 240 (D), 3.7 kg

2007, ZTE Corporation. All rights reserved.

ZXMW PR10 V4 SNMP Network


Management

Intuitive, proactive SNMP network management system


CIT base on WEB Technology
User-friendly interface
Hierarchical views
Simple configuration
In-service performance monitoring of the transmission quality
Remote download of configuration/software (TFTP)
Multiple software configurations can be stored
10/100 Base-T access, with cascading between IDUs

2007, ZTE Corporation. All rights reserved.

ZXMW PR10 V4 Released and Future


Products
ZXMW PR10 V4 - Released Product
IDU
2/4/8/16/32E1
2/4/8/16E1 + 410/100 Base-T
ODU (Frequencies) :
ODU A1: 7G, 8G, 13G, 15G
ODU A2: 18G, 23G, 26G, 38G
Protected Link
HSB
SD

2007, ZTE Corporation. All rights reserved.

ZXMW PR10 V4 Series

HW MODULES

2007, ZTE Corporation. All rights reserved.

ZXMW PR10 V4 Series

IDU Indoor Unit

2007, ZTE Corporation. All rights reserved.

IDU-Indoor Unit

IDU V4.0

2007, ZTE Corporation. All rights reserved.

IDU V4.0 General Overview

2007, ZTE Corporation. All rights reserved.

IDU V4.0 Practicality Picture

2007, ZTE Corporation. All rights reserved.

IDU V4.0 Inside Structure

2007, ZTE Corporation. All rights reserved.

IDU V4.0 Front panel


RJ45, EOW Interface,
connection to handset
EOW Call
Button
Modem
Status LED

DB-15-F, EDI Interface,


2 relay contacts, 2
external inputs

DB-3-F Power Connector,


-48V DC In (-40 to -58V)
Fuse

4x10/100Base-T

System
Status LED
RJ45, NMS
LA Interface
ODU
Status LED
System
Reset
Button

DB-44-F, Traffic
Interface, 8xE1
IN/OUT
RJ45, DSC Interface,
G.703 64k co-directional

RJ45, NMS
LAN Interface

Self-lock Switch,
Power On/Off

Coaxial N-Type
Female, IF Interface,
connection to ODU

2007, ZTE Corporation. All rights reserved.

IDU V4.0 Interface Connectors


Panel Identifier

Location Connector Type

Function

NM S LAN

CU

RJ45

Web-CIT or NMS access

NM S LA

CU

RJ45

Web-CIT or NMS access

TRAFFIC IN/OUT CH1 to CH8

CU

D-SUB, 44 pins

E1 Traffic Access

TRAFFIC IN/OUT CH9 to CH16

CU

D-SUB, 44 pins

E1 Traffic Access

EDI IN/OUT

SU

D-SUB, 15 pins

2 Relays and 2 External Inputs

DSC

SU

RJ45

E0 Additional Service Access

EOW

SU

RJ45

Orderwire Handset Access

TRAFFIC IN/OUT CH17 to CH24

E1 TU

D-SUB, 44 pins

E1 Traffic Access

TRAFFIC IN/OUT CH25 to CH32

E1 TU

D-SUB, 44 pins

E1 Traffic Access

IF IN/OUT

MU

N Type Coxial

Connection to ODU

48V DC IN

MU

D-SUB, 3 pins power

DC Power Input

2007, ZTE Corporation. All rights reserved.

IDU V4.0 EDI Connection Pin-out

Pin Number Signal Name Direction


1
EDI_OUT1a
O
2
EDI_OUT1b
O
3
EDI_IN1+
I
4
NC
5
NC
6
EDI_IN2+
I
7
EDI_OUT2a
O
8
EDI_OUT2b
O
9
EDI_OUT1com
O
10
GND
O
11
EDI_IN1I
12
GND
O
13
EDI_IN2I
14
GND
O
15
EDI_OUT2com
O

Function
Relay Contact 1
Relay Contact 1
External Input 1
No Connection
No Connection
External Input 2
Relay Contact 2
Relay Contact 2
Relay Contact 1
Ground
External Input 1
Ground
External Input 2
Ground
Relay Contact 2

Pin 5

Pin 1

Pin 15

Pin 11

2007, ZTE Corporation. All rights reserved.

IDU V4.0 E1 Traffic Connection Pin-out


Pin Number
1
Pin Number
2
25
3
26
4
5
27
6
28
7
29
8
30
9
31
10
32
11
33
12
34
13
35
14
36
15
37
16
38
17
39
18
40
19
41
20
42
21
43
22
44
23
24

Signal name
R1+
Signal
R1-name

T4+
NC
T4R2+
R2NC
NC
T5+
R3+
T5R3NC
NC
R6+
R4+
R6R4T6+
NC
T6R5+
NC
R5R7+
NC
R7T1+
T7+
T1T7NC
NC
T2+
R8+
T2R8NC
T8+
T3+
T8T3-

120 Ohm impedance


Tributary 1/9/17/25 input (hot wire)
Ohm impedance
Tributary120
1/9/17/25
input (cold wire)

75 Ohm impedance
Tributary 1/9/17/25 input
75 Ohm
impedance
Ground

Tributary 4/12/20/28 output (hot wire) Tributary 4/12/20/28 output


Tributary2/10/18/26
4/12/20/28input
output
(cold
Ground input
Tributary
(hot
wire)wire)Tributary 2/10/18/26
Tributary 2/10/18/26 input (cold wire)
Ground
Tributary 5/13/21/29 output (hot wire) Tributary 5/13/21/29 output
Tributary
(hot
wire)wire)Tributary 3/11/19/27
Tributary3/11/19/27
5/13/21/29input
output
(cold
Ground input
Tributary 3/11/19/27 input (cold wire)
Ground
Tributary 6/14/22/30 input (hot wire)
Tributary 6/14/22/30 input
Tributary
(hot
wire)
Tributary4/12/20/28
6/14/22/30input
input
(cold
wire) Tributary 4/12/20/28
Ground input
Tributary
4/12/20/28
input
(cold
wire)
Ground
Tributary 6/14/22/30 output (hot wire) Tributary 6/14/22/30 output

Pin 15
Pin 30

Pin 1
Pin 16

Tributary 6/14/22/30 output (cold wire)


Ground
Tributary 5/13/21/29 input (hot wire)
Tributary 5/13/21/29 input
Tributary
5/13/21/29
input
(cold
wire)
Ground
Tributary
7/15/23/31
input
(hot
wire)
Tributary
7/15/23/31 input
Tributary 7/15/23/31 input (cold wire)
Ground
Tributary 1/9/17/25 output (hot wire)
Tributary 1/9/17/25 output
Tributary 7/15/23/31 output (hot wire) Tributary 7/15/23/31 output
Tributary 1/9/17/25 output (cold wire)
Ground
Tributary 7/15/23/31 output (cold wire)
Ground
Tributary 2/10/18/26 output (hot wire) Tributary 2/10/18/26 output
Tributary 8/16/24/32 input (hot wire)
Tributary 8/16/24/32 input
Tributary 2/10/18/26 output (cold wire)
Ground
Tributary 8/16/24/32 input (cold wire)
Ground
Tributary
8/16/24/32
output
(hot
wire)
Tributary
8/16/24/32
output
Tributary 3/11/19/27 output (hot wire) Tributary 3/11/19/27 output
Tributary
8/16/24/32
output
(cold
wire)
Ground
Tributary 3/11/19/27 output (cold wire)
Ground

Pin 44

Pin 31

NC

2007, ZTE Corporation. All rights reserved.

IDU V4.0 DSC Connection Pin-out

Pin Number
1
2
3
4
5
6
7
8

Signal Name
RRING
RTIP
NC
NC
TRING
TTIP
NC
NC

Direction
I
I

O
O

Function
DSC Data In
DSC Data In
No Connection
No Connection
DSC Data Out
DSC Data Out
No Connection
No Connection

Standard
G.703
G.703

G.703
G.703

2007, ZTE Corporation. All rights reserved.

IDU V4.0 EOW Connection Pin-out

Pin Number
1
2
3
4
5
6
7
8

Signal Name
NC
NC
MICSPKSPK+
MIC+
NC
NC

Direction

Function
No Connection
No Connection
ECM negative
Speaker input
Speaker input
ECM positive
No Connection
No Connection

Standard

Analog
Analog
Analog
Analog

2007, ZTE Corporation. All rights reserved.

IDU V4.0 NM1/2 Connection Pin-out

Pin Number
1
2
3
4
5
6
7
8

Signal Name
TX1+
TX1RX1+
NC
NC
RX1NC
NC

Direction
Function
Standard
O
Transmit positive
Analog
O
Transmit negative
Analog
I
Receive positive
Analog
Not connected
Not connected
I
Receive negative
Analog
Not connected
Not connected

2007, ZTE Corporation. All rights reserved.

IDU V4.0 DC Power Connection Pin-out

Pin Number
A1
A2
A3

Signal Name
GND
-48V In
NC

Direction

Pin A1

Function
Ground
-48V Power
Not Connect
Pin A3

Pin A2

2007, ZTE Corporation. All rights reserved.

IDU V4.0 IDU to ODU Interconnect


A recommended coaxial cable to connect between IDU and ODU
Cable Interface
Single coaxial cable for both TX and RX
Cable type
RG-8 or equivalent
Rated impedance
50 Ohm
Maximum cable length
Up to 300 meters (1000 ft.)/QPSK
Connector type
N type Male Connector
Signal running along the cable

Tx nominal frequency
310/330 MHz
Rx nominal frequency
70/140 MHz
Transceiver management signals
388 kbit/s, bidirectional
Carrier for transceiver management signals
IDU to ODU = 17.5 MHz/0 dBm, ODU to IDU = 5.5 MHz/0 dBm
Remote power supply
direct from battery voltage

2007, ZTE Corporation. All rights reserved.

IDU V4.0 Hardware Versions

1 rack unit compact IDU, 1+0 configuration, 2/4/8/16/32xE1


1 rack unit compact IDU, 1+0 configuration, 2/4/8/16xE1 plus Eth

2007, ZTE Corporation. All rights reserved.

IDU V4.0 Modules

Module Name Description


TM U
ETH TU

Funciton

Main Unit - includes core unit, service unit and modem unit. A power
Traffic
Modulation Unit supply, a modulator/demodulator of baseband signal
Eth Traffic Unit

Optional - an integrated traffic interface module for up to 4 10/100 Base T


ethernet channels

2007, ZTE Corporation. All rights reserved.

IDU V4.0 PCB

2007, ZTE Corporation. All rights reserved.

IDU V4.0 HW Structure Diagram


LED

CPU

E1
E0
EOW

IP

E1

ETH

5V 3.3V

SMA

2.5V 1.8V 1.2V

48V

2007, ZTE Corporation. All rights reserved.

IDU-Indoor Unit

IDU V4.4

2007, ZTE Corporation. All rights reserved.

IDU V4.4 Practicality Picture

2007, ZTE Corporation. All rights reserved.

IDU V4.4 Inside Structure


Ethernet Traffic Unit
(Eth TU)

Service Unit (SU)

Backplane (BP)

Modem Unit (MU) B

Fan Unit (FU)

Core Unit (CU)

Two Fans
Modem Unit (MU) A

2007, ZTE Corporation. All rights reserved.

IDU V4.4 Front panel


EOW Call
Button

RJ45, DSC Interface,


G.703 64k co-directional

RJ45, EOW Interface,


connection to handset

DB-15-F, EDI Interface,


2 relay contacts, 2
external inputs

DB-3-F Power Connector,


-48V DC In (-40 to -58V)
Ground

Fuse

4x10/100Base-T

Alarm/Main
t Status
LED

System
Reset
Button

RJ45, NMS
LA Interface
RJ45, NMS
LAN Interface

ODU
Status LED
Self-lock Switch,
Power On/Off

DB-44-F, Traffic
Interface, 8xE1
IN/OUT

Coaxial N-Type
Female, IF Interface,
connection to ODU

MU
Status LED

2007, ZTE Corporation. All rights reserved.

IDU V4.4 Interface Connectors


Panel Identifier

Location Connector Type

Function

NM S LAN

CU

RJ45

Web-CIT or NMS access

NM S LA

CU

RJ45

Web-CIT or NMS access

TRAFFIC IN/OUT CH1 to CH8

CU

D-SUB, 44 pins

E1 Traffic Access

TRAFFIC IN/OUT CH9 to CH16

CU

D-SUB, 44 pins

E1 Traffic Access

EDI IN/OUT

SU

D-SUB, 15 pins

2 Relays and 2 External Inputs

DSC

SU

RJ45

E0 Additional Service Access

EOW

SU

RJ45

Orderwire Handset Access

TRAFFIC IN/OUT CH17 to CH24

E1 TU

D-SUB, 44 pins

E1 Traffic Access

TRAFFIC IN/OUT CH25 to CH32

E1 TU

D-SUB, 44 pins

E1 Traffic Access

IF IN/OUT

MU

N Type Coxial

Connection to ODU

48VDC IN

MU

D-SUB, 3 pins power

DC Power Input

2007, ZTE Corporation. All rights reserved.

IDU V4.4 EDI Connection Pin-out

Pin Number Signal Name Direction


1
EDI_OUT1a
O
2
EDI_OUT1b
O
3
EDI_IN1+
I
4
NC
5
NC
6
EDI_IN2+
I
7
EDI_OUT2a
O
8
EDI_OUT2b
O
9
EDI_OUT1com
O
10
GND
O
11
EDI_IN1I
12
GND
O
13
EDI_IN2I
14
GND
O
15
EDI_OUT2com
O

Function
Relay Contact 1
Relay Contact 1
External Input 1
No Connection
No Connection
External Input 2
Relay Contact 2
Relay Contact 2
Relay Contact 1
Ground
External Input 1
Ground
External Input 2
Ground
Relay Contact 2

Pin 5

Pin 1

Pin 15

Pin 11

Note: D-SUB15 Pin-out Definition.

2007, ZTE Corporation. All rights reserved.

IDU V4.4 E1 Traffic Connection Pin-out


Pin Number
1
Pin Number
2
25
3
26
4
5
27
6
28
7
29
8
30
9
31
10
32
11
33
12
34
13
35
14
36
15
37
16
38
17
39
18
40
19
41
20
42
21
43
22
44
23
24

Signal name
R1+
Signal
R1-name

T4+
NC
T4R2+
R2NC
NC
T5+
R3+
T5R3NC
NC
R6+
R4+
R6R4T6+
NC
T6R5+
NC
R5R7+
NC
R7T1+
T7+
T1T7NC
NC
T2+
R8+
T2R8NC
T8+
T3+
T8T3-

120 Ohm impedance


Tributary 1/9/17/25 input (hot wire)
Ohm impedance
Tributary120
1/9/17/25
input (cold wire)

75 Ohm impedance
Tributary 1/9/17/25 input
75 Ohm
impedance
Ground

Tributary 4/12/20/28 output (hot wire) Tributary 4/12/20/28 output


Tributary2/10/18/26
4/12/20/28input
output
(cold
Ground input
Tributary
(hot
wire)wire)Tributary 2/10/18/26
Tributary 2/10/18/26 input (cold wire)
Ground
Tributary 5/13/21/29 output (hot wire) Tributary 5/13/21/29 output
Tributary
(hot
wire)wire)Tributary 3/11/19/27
Tributary3/11/19/27
5/13/21/29input
output
(cold
Ground input
Tributary 3/11/19/27 input (cold wire)
Ground
Tributary 6/14/22/30 input (hot wire)
Tributary 6/14/22/30 input
Tributary
(hot
wire)
Tributary4/12/20/28
6/14/22/30input
input
(cold
wire) Tributary 4/12/20/28
Ground input
Tributary
4/12/20/28
input
(cold
wire)
Ground
Tributary 6/14/22/30 output (hot wire) Tributary 6/14/22/30 output

Pin 15
Pin 30

Pin 1
Pin 16

Tributary 6/14/22/30 output (cold wire)


Ground
Tributary 5/13/21/29 input (hot wire)
Tributary 5/13/21/29 input
Tributary
5/13/21/29
input
(cold
wire)
Ground
Tributary
7/15/23/31
input
(hot
wire)
Tributary
7/15/23/31 input
Tributary 7/15/23/31 input (cold wire)
Ground
Tributary 1/9/17/25 output (hot wire)
Tributary 1/9/17/25 output
Tributary 7/15/23/31 output (hot wire) Tributary 7/15/23/31 output
Tributary 1/9/17/25 output (cold wire)
Ground
Tributary 7/15/23/31 output (cold wire)
Ground
Tributary 2/10/18/26 output (hot wire) Tributary 2/10/18/26 output
Tributary 8/16/24/32 input (hot wire)
Tributary 8/16/24/32 input
Tributary 2/10/18/26 output (cold wire)
Ground
Tributary 8/16/24/32 input (cold wire)
Ground
Tributary
8/16/24/32
output
(hot
wire)
Tributary
8/16/24/32
output
Tributary 3/11/19/27 output (hot wire) Tributary 3/11/19/27 output
Tributary
8/16/24/32
output
(cold
wire)
Ground
Tributary 3/11/19/27 output (cold wire)
Ground

Pin 44

Pin 31

NC

Note: D-SUB44 Pin-out Definition.

2007, ZTE Corporation. All rights reserved.

IDU V4.4 DSC Connection Pin-out

Pin Number
1
2
3
4
5
6
7
8

Signal Name
RRING
RTIP
NC
NC
TRING
TTIP
NC
NC

Direction
I
I

O
O

Function
DSC Data In
DSC Data In
No Connection
No Connection
DSC Data Out
DSC Data Out
No Connection
No Connection

Standard
G.703
G.703

G.703
G.703

2007, ZTE Corporation. All rights reserved.

IDU V4.4 EOW Connection Pin-out

Pin Number
1
2
3
4
5
6
7
8

Signal Name
NC
NC
MICSPKSPK+
MIC+
NC
NC

Direction

Function
No Connection
No Connection
ECM negative
Speaker input
Speaker input
ECM positive
No Connection
No Connection

Standard

Analog
Analog
Analog
Analog

2007, ZTE Corporation. All rights reserved.

IDU V4.4 NM1/2 Connection Pin-out

Pin Number
1
2
3
4
5
6
7
8

Signal Name
TX1+
TX1RX1+
NC
NC
RX1NC
NC

Direction
Function
Standard
O
Transmit positive
Analog
O
Transmit negative
Analog
I
Receive positive
Analog
Not connected
Not connected
I
Receive negative
Analog
Not connected
Not connected

2007, ZTE Corporation. All rights reserved.

IDU V4.4 DC Power Connection Pin-out

Pin Number
A1
A2
A3

Signal Name
GND
-48V In
NC

Direction

Pin A1

Function
Ground
-48V Power
Not Connect
Pin A3

Pin A2

2007, ZTE Corporation. All rights reserved.

IDU V4.4 IDU to ODU Interconnect


A recommended coaxial cable to connect between IDU and ODU
Cable Interface
Single coaxial cable for both TX and RX
Cable type
RG-8 or equivalent
Rated impedance
50 Ohm
Maximum cable length
Up to 300 meters (1000 ft.)/QPSK
Connector type
N type Male Connector
Signal running along the cable

Tx nominal frequency
310/330 MHz
Rx nominal frequency
70/140 MHz
Transceiver management signals
388 kbit/s, bidirectional (A2)
Carrier for transceiver management signals (A2)
IDU to ODU = 17.5 MHz/0 dBm, ODU to IDU = 5.5 MHz/0 dBm
Remote power supply
direct from battery voltage

2007, ZTE Corporation. All rights reserved.

IDU V4.4 Hardware Versions

1 rack unit compact IDU, 1+1 configuration, 2/4/8/16xE1


1 rack unit compact IDU, 1+1 configuration, 2/4/8/16xE1 plus 4xEth

2007, ZTE Corporation. All rights reserved.

IDU V4.4 Modules


Module Name Description

CU

Core Unit

Funciton
Main Unit - an integrated traffic interface module for up to 16 E1 channels,
room for an optionally plugged TU, room for an optionally plugged SU, a
service multiplexer for service individual multiplexing / demultiplexing, a
radio inter-working function for adaptation of the signals to the modem
format, a radio protection switching function (RPS) to switch between two
receive
paths;
a micro-controller
Main Unit
- a power
supply, the digital modulator/demodulator and the

Modem Unit

conversion to and from an analogue intermediate frequency. In protected


terminal configurations two identical Modem Units shall be present in the
IDU, the cable interface for bidirectional communication between ODU and
IDU, and implement the IF section of the mo-demodulator

SU

Service Unit

EDI with up to 2 input and 2 output contacts, the output contacts supporting
relay; a digital service channel (DSC) based on E0 [G.703], codirectional;
an engineering order wire (EOW)

ETH TU

Eth Traffic Unit

Optional - an integrated traffic interface module for up to 4 10/100 Base T


ethernet channels

FU

Fan Unit

BP

Backplane

MU

To apply fan control


To apply main unit interconnection

Note: To plug in/retrieve a Modem Unit into/from an IDU will not interrupting the traffic
on the active Modem Unit.

2007, ZTE Corporation. All rights reserved.

IDU V4.4 HW Structure Diagram


F

EOW
DSC
EDI

E1

MUI MUI

(E1)

SU
CU(Core Unit)

Back Plane

IDU
I-MIS-F

I-MIS-TU-E1/T1
I-MIS-E3/T3
I-MIS-ETH

I-MIS-EOW
I-MIS-EDI
I-MIS-DSC

TU
(E1/E3;
T1/T3;
ETH)

I-CU-TU

SU

I-CU-SU

I-MIS-Q

CU (Core Unit)

FU

I-MIS-CU-MU

I-MIS-CU-MU
I-MIS-CU-MU & I-MIS-CU-FM

I-MIS-CU-FM

Back Plane

2007, ZTE Corporation. All rights reserved.

IDU V4.4 PCB

2007, ZTE Corporation. All rights reserved.

IDU V4.4 Core Unit

Mounting Hole
for Optional
Card

Connector for
Expanded SU

Connector for
Expanded Eth
TU

CU contains Micro-processor, 16MB Flash, Multiplex/De-Multiplex,


4/8/16E1 Traffic Interface Section, NMS Interface Section
2007, ZTE Corporation. All rights reserved.

IDU V4.4 Core Unit Block Diagram


Manufacture

& For Debug

BDM

3.3V

RS- 232

3.3V

16*E1

16

POW

E1

1.8V

3.3V
LED

5*16

5
SPI

Rx_ Symb_Clk
System_Clk( LVDS)
spare

FPGA_ CONFG_SU
MUX_SU( LVDS)

Q
SMC

LED

2.5V

31

FEC

SPI

SCC

ODU_OOK_TX
ODU_OOK_RX

SCC

ODU_OOK_TX
ODU_OOK_RX

3.3V 1.2V

2
2
3
3

FPGA
CONFIG

CPU
MUX

FPGA_ CONFG_TU
MUX_TU( LVDS)

ETHSW
BDM

31

UTOPIA

MII

3.3V

&

5
12
5

DEMUX

SPI

NE Management
packet

5
12

SPI

HWID
SPI
SPI

SCC

SPI
SPI
I2C

SPI

I2C

5
5
10
10
2

SPI_TU
SPI_SU
SPI_MU
FU

CLK

IFCTRL

2
2

OPCTL

3
3

SSPRG

5
5

Local Bus

EPLD

Boot

SDRAM

Flash

2007, ZTE Corporation. All rights reserved.

IDU V4.4 Service Unit

Mounting Hole

SU contains Multiplex/De-Multiplex, EDI Interface Section, EOW


Interface Section, DSC Interface Section

2007, ZTE Corporation. All rights reserved.

IDU V4.4 Service Unit Block Diagram


MIC+

MCLK

MIC-

PCM Codec
(PCM)

SPEAKER+
SPEAKER-

BCLKR/T

FSR/T

12
GND

Dx
Dr

DSC_D_IN+
DSC_IN1/2

DSC_D_INDSC_CK_IN+
DSC_CK_IN-

MUX Signal
Bus(LVTTL)

Receiver
V.11 PHY(PHY)

DSC_OUT1/2

DSC_D_OUT+
DSC_D_OUT-

Driver

DSC_CK_OUT+
DSC_CK_OUT-

Mux/Demux And Control


(MDC)

12

LVDS
Transceiver

MUX Signal Bus(LVDS)

Interface and
driver(ID)

FPGA
CONFIG

SPI

5
FPGA CONFIG

Driver

SPI

Call_int
Call_out

EDI_IN1/2+

EDI_IN1/2-

EDI _OUT1/2a

EDI _OUT1/2com

EDI _OUT1/2b

Front Panel

Optical Coupler
(OC)

EDI_IN1/2

1.8V
3.3V

Relay
(REL)

DC-DC
(DC)

14

3.3V

5V
EDI_OUT1/2

CU Board

2007, ZTE Corporation. All rights reserved.

IDU V4.4 Core Unit plugged Optional SU

2007, ZTE Corporation. All rights reserved.

IDU V4.4 Eth Traffic Unit (Optional)

Mounting Hole

Eth TU contains Ethernet interface section with four Ethernet ports

2007, ZTE Corporation. All rights reserved.

IDU V4.4 Eth Traffic Unit Block Diagram

Int

10/100Base-T

Tx

10/100Base-T

Tx Framer
MII

10/100Base-T

5-port Ethernet Switch

10/100Base-T

Rx

Rx DeFramer

2007, ZTE Corporation. All rights reserved.

IDU V4.4 Core Unit plugged Optional SU


and Eth TU

2007, ZTE Corporation. All rights reserved.

IDU V4.4 Modem Unit

MU contains Power Supply Section, IF Section, Modem Section,


Telemetry Section, Cable MUX Section
2007, ZTE Corporation. All rights reserved.

IDU V4.4 Modem Unit Block


Diagram
12M

CLOCK

93M/12M

93M

330M

140M

A/D
D/A

IF
TRX

BP
INTFC

DSP

Cable
MUX
TX_OOK/RX_OOK

TELEMETRY
6V

5V

3.3V 2.5V 1.8V

1.2V
3.3V

48V
DC-DC Converter
12V

2007, ZTE Corporation. All rights reserved.

IDU V4.4 Back Plane


Connector for
MUB plug in

Connector for
CU plug in

Connector for
MUA plug in

Connector for
FU plug in

2007, ZTE Corporation. All rights reserved.

IDU V4.4 Back Plane Block Diagram

Back Plane
I-CU-FU

I-FU-CU-MU

To FU

To CU

I-CU-MU

I-CU-MU

I-CU-MU

To MU B

To MU A

2007, ZTE Corporation. All rights reserved.

IDU V4.4 I/O Board (16E1, 75ohm)

D-SUB44-M - 1M D-SUB44-M Cable


Connect I/O board to IDU front panel connector

D-Sub44-Female
E1: CH1 - CH8

D-Sub44-Female
E1: CH9 CH16

2007, ZTE Corporation. All rights reserved.

IDU-Indoor Unit

IDU LED Status

2007, ZTE Corporation. All rights reserved.

LEDs Status V4.0


Label

Color
Green

Action

Meaning

Off

The system is turn off.

On

The system is operating properly. No any alarm.

Slow Flashing The system is booting.


SYSTEM

Red
Yellow

On

Major alarm, details need to check through Web-CIT.

Slow Flashing The system have configuraion error during booting.


On

Minor alarm, details need to check through Web-CIT.

Slow Flashing The system have fault during booting, but not effect traffic.

2007, ZTE Corporation. All rights reserved.

LEDs Status V4.0


Label

Color
Green

MODEM

Red

Meaning

Off

The system is turn off.

On

The MU is operating properly

On

The MU has failed.

Fast Flashing The modem is synchronizing.

Off

The ODU is absent.

On

The ODU is operating properly.

Red

On

The ODU has failed.

Yellow

On

In a protected system, the MU is in redundant state.

Green
ODU

Action

2007, ZTE Corporation. All rights reserved.

LEDs Status V4.4


Module

Label

Color

Action
Off

Meaning
The system is turn off.
The system is operating properly. No
On
Green
any alarm.
Slow Flashing The system is booting.
Major alarm, details need to check
On
through Web-CIT.
Core Unit ALARM/MAINT Red
The system have configuraion error
Slow Flashing
during booting.
Minor alarm, details need to check
On
through Web-CIT.
Yellow
The system have fault during booting,
Slow Flashing
but not effect traffic.

2007, ZTE Corporation. All rights reserved.

LEDs Status V4.4


Module

Label

MU
Modem Unit

ODU

Color

Action
Off
Green
On
On
Red
Fast Flashing

Meaning
The system is turn off.
The MU is operating properly
The MU has failed.
The modem is synchronizing.
In a protected system, the MU is in
On
redundant state.
Yellow
The redundant modem is
Fast Flashing
synchronizing.
Off
The ODU is absent.
Green
On
The ODU is operating properly.
Red
On
The ODU has failed.
In a protected system, the MU is in
Yellow
On
redundant state.

2007, ZTE Corporation. All rights reserved.

Glossary of Alarms (1)


Description
Major alarm
Minor alarm
Remote alarm
BER alarm

Explanation
The system have major alarm.
The system have minor alarm.
The remote system have alarm.
BER is above the threshold.
Indicates that a module is not inserted and powered in the
ODU A absent alarm
ODU A slot.
Indicates that a module is not inserted and powered in the
ODU B absent alarm
ODU B slot.
The system could not restore the configuration from the
Config file load failure alarm
config files; the default values were used.
Radio link failure alarm
The Rx demux cannot synchronize on main traffic.
Radio Network comm failure alarm The network communication over radio failed.
Switch over failure alarm
Switchover operation failed.
Temperature raised alarm
IDU operating tempreture is above threshold.
Indicates that a module is not inserted and powered in the
MU A absent alarm
MU A slot.
Indicates that a module is not inserted and powered in the
MU B absent alarm
MU B slot.
CU Card unknown alarm
There is an unknown card in CU slot.
CU FPGA config failure alarm
The CU FPGA download failed.
E1 TU Card unknown alarm
There is an unknown card in TU slot.
E1 TU FPGA config failure alarm
The TU FPGA download failed.
SU Card unknown alarm
There is an unknown card in SU slot.
SU FPGA config failue alarm
The SU FPGA download failed.

Alarm Level
Major
Minor
Minor
Major
Major
Major
Major
Major
Major
Major
Minor
Major
Major
Major
Major
Major
Major
Major
Major

2007, ZTE Corporation. All rights reserved.

Glossary of Alarms (2)


Description
DSC Inward loopback alarm
DSC Line loopback alarm
External input 1 alarm
External input 2 alarm
MU A Card unknown alarm
MU A FPGA config failure alarm
Modem A Sync failure alarm
MU A TX CWTone alarm
MU B Card unknown alarm
MU B FPGA config failure alarm
Modem B Sync failure alarm
MU B TX CWTone alarm
ODU A TX manual mute alarm
ODU A Software download failure alarm
ODU A IF TX PLL is unlocked
ODU A IF RX PLL is unlocked
ODU A RF TX PLL is unlocked
ODU A RF RX PLL is unlocked
ODU A Power Amplifer alarm
ODU A RSL alarm
ODU A IF TX AGC is unlocked

Explanation
DSC inward loopback is set.
DSC line loopback is set.
External input 1 indicates an alarm condition.
External input 2 indicates an alarm condition.
There is an unknown card in MU A slot.
The MU A FPGA download failed.
The modem A Rx cannot synchronize on the incoming IF
signal.
CW-tone mode is set on Tx_A.
There is an unknown card in MU B slot.
The MU B FPGA download failed.
The modem B Rx cannot synchronize on the incoming IF
signal.
CW-tone mode is set on Tx_B.
ODU A is manually muted.
The ODU A software download failed.
The Tx A IF oscillator is not locked up.
The Rx A IF oscillator is not locked up.
The Tx A RF oscillator is not locked up.
The Rx A RF oscillator is not locked up.
The PA A output is low (more than 3 dB below the set
value).
The RSL of ODU A is below the system threshold.
The Tx A IF AGC is not locked up.

Alarm Level
Minor
Minor
Minor
Minor
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major

2007, ZTE Corporation. All rights reserved.

Glossary of Alarms (3)


Description
DSC Inward loopback alarm
ODU A IF RX AGC is unlocked
ODU A EEPROM alarm
ODU A Power Supply failure alarm
ODU A Watch dog failure alarm
ODU B TX manual mute alarm
ODU B Software download failure alarm
ODU B IF TX PLL is unlocked
ODU B IF RX PLL is unlocked
ODU B RF TX PLL is unlocked
ODU B RF RX PLL is unlocked
ODU B Power Amplifer alarm
ODU B RSL alarm
ODU B IF TX AGC is unlocked
ODU B IF RX AGC is unlocked
ODU B EEPROM alarm
ODU B Power Supply failure alarm
ODU B Watch dog failure alarm
E1 x input LOS alarm
E1 x input line loopback alarm
E1 x input inward loopback alarm

Explanation
DSC inward loopback is set.
The Rx A IF AGC is not locked up.
The ODU A's EEPROM is not functional.
The ODU A's power supply failed.
The ODU A's watch dog failed.
ODU B is manually muted.
The ODU B software download failed.
The Tx B IF oscillator is not locked up.
The Rx B IF oscillator is not locked up.
The Tx B RF oscillator is not locked up.
The Rx B RF oscillator is not locked up.
The PA B output is low (more than 3 dB below the set
value).
The RSL of ODU B is below the system threshold.
The Tx B IF AGC is not locked up.
The Rx B IF AGC is not locked up.
The ODU B's EEPROM is not functional.
The ODU B's power supply failed.
The ODU B's watch dog failed.
E1 tributary x: No input signal from the customer.
E1 tributary x input loopback is set.
E1 tributary x inward loopback is set.

Alarm Level
Minor
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major

2007, ZTE Corporation. All rights reserved.

ZXMW PR10 V4 Series

ODU Outdoor Unit

2007, ZTE Corporation. All rights reserved.

ODU - Outdoor Unit


ODU A1: 7GHz, 8GHz, 13GHz, 15GHz
ODU A2: 18GHz, 23GHz, 26GHz, 38GHz

ODU A1

ODU A2

2007, ZTE Corporation. All rights reserved.

ODU - Outdoor Unit

Independent of capacity
Small, compact, light
weight and aesthetic
easily blends into the
ODU A1
local environment.
ODU can be installed
ODU A2
either directly on \ with
the antenna or separately.

Antenna

Antenna

2007, ZTE Corporation. All rights reserved.

ODU - Outdoor Unit

ODU A1

2007, ZTE Corporation. All rights reserved.

ODU A1- Block Diagram

2007, ZTE Corporation. All rights reserved.

ODU A1- Connectors

BNC

Ground bolt

Connector Type

Description

Coaxial N-type female connector

Cable interfacing IDU and ODU

BNC-type female connector

Connection to a multimeter with the purpose to alignment and test

Ground bolt

Connection to ground system

2007, ZTE Corporation. All rights reserved.

ODU A1- 1+0

2007, ZTE Corporation. All rights reserved.

ODU A1 1+1 Hot-Standby (by 1 antenna)

2007, ZTE Corporation. All rights reserved.

ODU A1 1+1 Hot-Standby (by 2 antenna)

2007, ZTE Corporation. All rights reserved.

1+0 ODU A1 With Integral Antenna


(Pole Mounting)

2007, ZTE Corporation. All rights reserved.

1+1 ODU A1 With Integral Antenna


(Pole Mounting)

2007, ZTE Corporation. All rights reserved.

1+0 ODU A1 With Separated Antenna


(Pole Mounting)

2007, ZTE Corporation. All rights reserved.

1+1 ODU A1 With Separated Antenna


(Pole Mounting)

2007, ZTE Corporation. All rights reserved.

1+0 ODU A1 housing final position for


vertical polarization
Polarization hole

Back loop
Feed source

2007, ZTE Corporation. All rights reserved.

1+0 ODU A1 housing final position for


Horizontal polarization
Polarization hole

Back loop

Feed source

2007, ZTE Corporation. All rights reserved.

ODU A1 Housing Final Position For 1+1

2007, ZTE Corporation. All rights reserved.

ODU - Outdoor Unit

ODU A2

2007, ZTE Corporation. All rights reserved.

ODU A2- Block Diagram

2007, ZTE Corporation. All rights reserved.

ODU A2- Connectors

BNC
Ground bolt

Connector Type

Description

Coaxial N-type female connector

Cable interfacing IDU and ODU

BNC-type female connector

Connection to a multimeter with the purpose to alignment and test

Ground bolt

Connection to ground system

2007, ZTE Corporation. All rights reserved.

ODU A2 1+0

2007, ZTE Corporation. All rights reserved.

ODU A2 1+1 Hot-Standby (by 1 antenna)

The two ODUs are coupled to the antenna side via a balanced or
unbalanced hybrid.

2007, ZTE Corporation. All rights reserved.

ODU A2 1+1 Hot-Standby (by 2 antenna)

2007, ZTE Corporation. All rights reserved.

1+0 ODU A2 With Integral Antenna


(Pole Mounting)

2007, ZTE Corporation. All rights reserved.

ODU A2 Direct Mount (1+0)

2007, ZTE Corporation. All rights reserved.

1+1 ODU A2 With Integral Antenna


(Pole Mounting)

2007, ZTE Corporation. All rights reserved.

ODU A2 Direct Mount (1+1)

2007, ZTE Corporation. All rights reserved.

1+0 ODU A2 With Separated Antenna


(Pole Mounting)

2007, ZTE Corporation. All rights reserved.

1+1 ODU A2 With Separated Antenna


(Pole Mounting)

2007, ZTE Corporation. All rights reserved.

1+0 ODU A2 housing final position for


vertical polarization

2007, ZTE Corporation. All rights reserved.

1+0 ODU A2 housing final position for


Horizontal polarization

2007, ZTE Corporation. All rights reserved.

ODU A2 Housing Final Position For 1+1

Hybrid Mount On Pole Support .

2007, ZTE Corporation. All rights reserved.

ATPC Operation

2007, ZTE Corporation. All rights reserved.

ZXMW PR10 V4 Series

SW MODULES

2007, ZTE Corporation. All rights reserved.

SW Modules

IDU Software

2007, ZTE Corporation. All rights reserved.

Front
Panel

FTP
Client

Telnet
Client

DHCP
Client

SNTP
Server

SNMP

FTP
Server

Telnet
Server

DHCP
Server

SNTP
Client

Data Handler
Control Tasks

Hardware

IDU Software Block Diagram

TCP/IP

PPP

LAN

2007, ZTE Corporation. All rights reserved.

IDU Software - TCP/IP

TCP/IP supports 3 basic applications:


SNMP, Telnet , FTP.
TCP/IP provide IP address to all interfaces (ports):
LAN
SNMP provides interface both ways (inputs and outputs) for Link
and Front Panel.
Telnet host can be used through LAN
FTP can be used through LAN

2007, ZTE Corporation. All rights reserved.

PPP Protocol

The Point-to-Point Protocol is designed for simple links which


transport packets between two peers. These links provide full-duplex
simultaneous bi-directional operation, PPP is comprised of three main
components:

1. A method for encapsulating multiprotocol datagram.


2. A Link Control Protocol (LCP) for
establishing, configuring, and
testing the data-link connection.
3. A family of Network Control
Protocols (NCPs) for establishing
and configuring different networklayer protocols.

IP

IPCP
PPP

LCP
Framing

Radio interface

2007, ZTE Corporation. All rights reserved.

SW Modules

ODU Software

2007, ZTE Corporation. All rights reserved.

ODU Software Block Diagram

Alarm managerment
SC
Protocol handler

Hardware

2007, ZTE Corporation. All rights reserved.

SW Modules

Management Software

2007, ZTE Corporation. All rights reserved.

Management Web-CIT

Web-CIT based on WEB Technology


Configuration Management
Performance Monitoring
Status and Fault Management
Test Activation and Monitoring
Software Update
Applications (Telnet)

2007, ZTE Corporation. All rights reserved.

Web-CIT Log in
Default settings
IP address: Obtain an IP address automatically
User name: admin
Password: admin

2007, ZTE Corporation. All rights reserved.

Web-CIT Main Screen

2007, ZTE Corporation. All rights reserved.

ZXMW PR10 V4 Series

Link Installation
and Setup

2007, ZTE Corporation. All rights reserved.

Link installation and setup


A: ODU installation initial setup
( This procedure will describe an ODU to be mounted directly on
antenna.)
1.Using open /close wrench , attach the antenna mount to the
pole in a general direction using any kind of azimuth device,
compass, etc.
2. Secure the antenna to the antenna mount (about 1/4 of a turn)
and secure the bolts that hold the antenna.
3. Attach the ODU to the antenna and secure the 4 clips that hold
the ODU. When the polarization is vertical, the N-type
connector should be at 7 oclock.
4. Connect the RG-8 cable, coming from the ODU, to the N-type
connector and secure it by hand.
5. Connect a DVM to the BNC socket on the ODU. Set the DVM
to DC volts to a range between 2-20 Volts (measurement will
be 0-3 V).

2007, ZTE Corporation. All rights reserved.

Link installation and setup


B: IDU installation initial setup
1. Connect the Coax cable (RG-8 coming from the ODU) to
Coaxial N-Type female connector on the IDU.
2. Connect the IDU to a power source (22-60V DC).
3. Verify the polarity of the power cable. Polarity is especially
important when IDU is installed on a rack mount (19 rack).
4. Turn on the main power switch or power breaker to supply DC
to the IDU (-40 ~ -58V DC).
5. Set the initial parameters according to your system (Frequency,
Link Capacity and Tx Power).
6. Check the Web-CIT display parameters.
7. An RSL value of NA, means there is no signal being received.
8. Check for a reasonable RSL value (before antenna alignment).
9. Please refer to Doc ZXMW PR10 V4 Radio Microwave
System Operation Manual.

2007, ZTE Corporation. All rights reserved.

Link installation and setup


C: Final adjustment
1. The final adjustment is done, always on both sides of the link,
at the antenna. It has to be done one by one and not
simultaneously.
2. Using the DVM and the fine tilt adjustment of the antenna
mount, adjust the pitch and direction of the antenna to get
maximum received signal.
3. The average signal strength should be, in good weather,
above 2 V DC reading on the DVM, but also according to the
path calculation.
4. The voltage is positive (+) and increases with the signal
strength (the better the signal the more voltage).
***The best results are when both sides have the same RSL***.
5. After getting the best results on both side, secure the antenna
mount, close and secure the test BNC connector cap.

2007, ZTE Corporation. All rights reserved.

Link installation and setup

Estimated values of RSL measured via the ODU BNC outlet (for A2)

2007, ZTE Corporation. All rights reserved.

Link installation and setup (1+0)


D: ODU installation initial setup
(This procedure will describe an ODU to be mounted separately
from the antenna using a wave guide to connect to the antenna).
1. Same as before, attach the antenna mount to the pole in the
right general direction.
2. Attach the ODU with a special \ separate mount to the pole.
3. Connect a wave guide between the ODU and the antenna.
4. Please verify the direction of the wave guide according to
the antenna and the ODU (vertical or horizontal).
5. Make sure the O-ring is in its place and firmly tight the wave
guide screws.
6. Follow the procedure (from step A4 and on) continue with
the ODU and IDU installation and final adjustment.

2007, ZTE Corporation. All rights reserved.

Thank you

2007, ZTE Corporation. All rights reserved


2007, ZTE Corporation. All rights reserved.