Beruflich Dokumente
Kultur Dokumente
Agenda
Specification
Released products / Future products
Agenda
SW Modules
IDU SW
ODU SW
Scalable Capacity
Spectrum on Demand The availability to configure bandwidth to
support various modes of operations by software command.
System to offer scalable data rates by a unique
digital modem design - one IDU for all capacities
Data rates from E1 (2 Mbps) to 16 E1 (32 Mbps)
Reduced logistics, spare parts and product stocking
2007, ZTE Corporation. All rights reserved.
ODU A1
ODU A2
Unprotected ODU
Protected ODU
7GHz
8 GHz
13 GHz
15GHz
7.11-7.9
7.725-8.5
12.75-13.25
14.5-15.35
F.385-7
Annex 1
Annex 4
CEPT/ERC
REC 02-06
F.386-6
Annex 1
Annex 3
Annex 4
F.497-6
CEPT/ERC
REC12-02
F.636-3
CEPT/ERC
REC12-07
119,126
305.56,311.32
266
420,490,728
18 GHz
23 GHz
26 GHz
38 GHz
Frequency
Range [GHz]
17.7-19.7
21.2-23.6
24.5-26.5
37.0-39.5
Frequency
Plan
ITU-R/CEPT
F.595-6
F.191
CEPT/ERC
REC12-03
F.637-3
CEPT/ERC REC
T/R 13-02
Annex A
F.748-3
CEPT/ERC
REC T/R 13-02
Annex B
F.749-1
CEPT/ERC
REC T/R 12-01
Channel
Separation
RF TX/RX
Spacing
[MHz]
1008
1008
1260
Configuration
1+0
1+1
A1
35W
35W2
A2
24W
24W2
with ODU A1
55W
115W
with ODU A2
45W
99W
IDU
ODU
Power
Consumption(Max)
Frequency(GHz)
Output Power
(dBm )
QPSK
13
15
18
23
26
38 Guaranteed
2.0 dB
Frequency(GHz)
QPSK
BER = 10-6
16QAM
16E1
8E1
4E1
32E1
16E1
8E1
4E1
7
-82.5
-85.0
-88.0
-74.0
-80.5
-83.0
-85.0
8
-82.0
-84.5
-87.5
-74.0
-80.0
-82.5
-84.5
13
-82.0
-85.0
-87.5
-73.0
-80.0
-82.5
-85.0
15
-82.0
-85.0
-87.5
-73.0
-80.0
-82.5
-85.0
18
-87.0
-90.0
-92.5
-82.5
-86.0
-88.5
-91.0
23
-85.0
-88.0
-91.0
-80.5
-84.0
-86.5
-89.0
26
-85.5
-88.5
-91.5
-81.0
-84.5
-87.0
-89.5
38 Guaranteed
-85.0
-88.0
-91.0
+1.0 dB
-79.5
-83.0
-85.5
-88.0
4.5
4.5
System Characteristics
13 15 18 23 26 38
Guaranteed
20 dB, in 1 dB step
1.0 dB
20 dB, in 1 dB step
5 ppm
10 ppm
1+0, 1+1 (HS), 1+1 (HS/SD), 1+1 (FD)
+2 dB (13/15/18G)
4.5 4.5 5.5 6.5
7
7.5
+1.5 dB(23/38G)
-20 dBm (No Error)
RX Signal Level
QPSK or 16QAM
HW MODULES
IDU-Indoor Unit
IDU V4.0
4x10/100Base-T
System
Status LED
RJ45, NMS
LA Interface
ODU
Status LED
System
Reset
Button
DB-44-F, Traffic
Interface, 8xE1
IN/OUT
RJ45, DSC Interface,
G.703 64k co-directional
RJ45, NMS
LAN Interface
Self-lock Switch,
Power On/Off
Coaxial N-Type
Female, IF Interface,
connection to ODU
Function
NM S LAN
CU
RJ45
NM S LA
CU
RJ45
CU
D-SUB, 44 pins
E1 Traffic Access
CU
D-SUB, 44 pins
E1 Traffic Access
EDI IN/OUT
SU
D-SUB, 15 pins
DSC
SU
RJ45
EOW
SU
RJ45
E1 TU
D-SUB, 44 pins
E1 Traffic Access
E1 TU
D-SUB, 44 pins
E1 Traffic Access
IF IN/OUT
MU
N Type Coxial
Connection to ODU
48V DC IN
MU
DC Power Input
Function
Relay Contact 1
Relay Contact 1
External Input 1
No Connection
No Connection
External Input 2
Relay Contact 2
Relay Contact 2
Relay Contact 1
Ground
External Input 1
Ground
External Input 2
Ground
Relay Contact 2
Pin 5
Pin 1
Pin 15
Pin 11
Signal name
R1+
Signal
R1-name
T4+
NC
T4R2+
R2NC
NC
T5+
R3+
T5R3NC
NC
R6+
R4+
R6R4T6+
NC
T6R5+
NC
R5R7+
NC
R7T1+
T7+
T1T7NC
NC
T2+
R8+
T2R8NC
T8+
T3+
T8T3-
75 Ohm impedance
Tributary 1/9/17/25 input
75 Ohm
impedance
Ground
Pin 15
Pin 30
Pin 1
Pin 16
Pin 44
Pin 31
NC
Pin Number
1
2
3
4
5
6
7
8
Signal Name
RRING
RTIP
NC
NC
TRING
TTIP
NC
NC
Direction
I
I
O
O
Function
DSC Data In
DSC Data In
No Connection
No Connection
DSC Data Out
DSC Data Out
No Connection
No Connection
Standard
G.703
G.703
G.703
G.703
Pin Number
1
2
3
4
5
6
7
8
Signal Name
NC
NC
MICSPKSPK+
MIC+
NC
NC
Direction
Function
No Connection
No Connection
ECM negative
Speaker input
Speaker input
ECM positive
No Connection
No Connection
Standard
Analog
Analog
Analog
Analog
Pin Number
1
2
3
4
5
6
7
8
Signal Name
TX1+
TX1RX1+
NC
NC
RX1NC
NC
Direction
Function
Standard
O
Transmit positive
Analog
O
Transmit negative
Analog
I
Receive positive
Analog
Not connected
Not connected
I
Receive negative
Analog
Not connected
Not connected
Pin Number
A1
A2
A3
Signal Name
GND
-48V In
NC
Direction
Pin A1
Function
Ground
-48V Power
Not Connect
Pin A3
Pin A2
Tx nominal frequency
310/330 MHz
Rx nominal frequency
70/140 MHz
Transceiver management signals
388 kbit/s, bidirectional
Carrier for transceiver management signals
IDU to ODU = 17.5 MHz/0 dBm, ODU to IDU = 5.5 MHz/0 dBm
Remote power supply
direct from battery voltage
Funciton
Main Unit - includes core unit, service unit and modem unit. A power
Traffic
Modulation Unit supply, a modulator/demodulator of baseband signal
Eth Traffic Unit
CPU
E1
E0
EOW
IP
E1
ETH
5V 3.3V
SMA
48V
IDU-Indoor Unit
IDU V4.4
Backplane (BP)
Two Fans
Modem Unit (MU) A
Fuse
4x10/100Base-T
Alarm/Main
t Status
LED
System
Reset
Button
RJ45, NMS
LA Interface
RJ45, NMS
LAN Interface
ODU
Status LED
Self-lock Switch,
Power On/Off
DB-44-F, Traffic
Interface, 8xE1
IN/OUT
Coaxial N-Type
Female, IF Interface,
connection to ODU
MU
Status LED
Function
NM S LAN
CU
RJ45
NM S LA
CU
RJ45
CU
D-SUB, 44 pins
E1 Traffic Access
CU
D-SUB, 44 pins
E1 Traffic Access
EDI IN/OUT
SU
D-SUB, 15 pins
DSC
SU
RJ45
EOW
SU
RJ45
E1 TU
D-SUB, 44 pins
E1 Traffic Access
E1 TU
D-SUB, 44 pins
E1 Traffic Access
IF IN/OUT
MU
N Type Coxial
Connection to ODU
48VDC IN
MU
DC Power Input
Function
Relay Contact 1
Relay Contact 1
External Input 1
No Connection
No Connection
External Input 2
Relay Contact 2
Relay Contact 2
Relay Contact 1
Ground
External Input 1
Ground
External Input 2
Ground
Relay Contact 2
Pin 5
Pin 1
Pin 15
Pin 11
Signal name
R1+
Signal
R1-name
T4+
NC
T4R2+
R2NC
NC
T5+
R3+
T5R3NC
NC
R6+
R4+
R6R4T6+
NC
T6R5+
NC
R5R7+
NC
R7T1+
T7+
T1T7NC
NC
T2+
R8+
T2R8NC
T8+
T3+
T8T3-
75 Ohm impedance
Tributary 1/9/17/25 input
75 Ohm
impedance
Ground
Pin 15
Pin 30
Pin 1
Pin 16
Pin 44
Pin 31
NC
Pin Number
1
2
3
4
5
6
7
8
Signal Name
RRING
RTIP
NC
NC
TRING
TTIP
NC
NC
Direction
I
I
O
O
Function
DSC Data In
DSC Data In
No Connection
No Connection
DSC Data Out
DSC Data Out
No Connection
No Connection
Standard
G.703
G.703
G.703
G.703
Pin Number
1
2
3
4
5
6
7
8
Signal Name
NC
NC
MICSPKSPK+
MIC+
NC
NC
Direction
Function
No Connection
No Connection
ECM negative
Speaker input
Speaker input
ECM positive
No Connection
No Connection
Standard
Analog
Analog
Analog
Analog
Pin Number
1
2
3
4
5
6
7
8
Signal Name
TX1+
TX1RX1+
NC
NC
RX1NC
NC
Direction
Function
Standard
O
Transmit positive
Analog
O
Transmit negative
Analog
I
Receive positive
Analog
Not connected
Not connected
I
Receive negative
Analog
Not connected
Not connected
Pin Number
A1
A2
A3
Signal Name
GND
-48V In
NC
Direction
Pin A1
Function
Ground
-48V Power
Not Connect
Pin A3
Pin A2
Tx nominal frequency
310/330 MHz
Rx nominal frequency
70/140 MHz
Transceiver management signals
388 kbit/s, bidirectional (A2)
Carrier for transceiver management signals (A2)
IDU to ODU = 17.5 MHz/0 dBm, ODU to IDU = 5.5 MHz/0 dBm
Remote power supply
direct from battery voltage
CU
Core Unit
Funciton
Main Unit - an integrated traffic interface module for up to 16 E1 channels,
room for an optionally plugged TU, room for an optionally plugged SU, a
service multiplexer for service individual multiplexing / demultiplexing, a
radio inter-working function for adaptation of the signals to the modem
format, a radio protection switching function (RPS) to switch between two
receive
paths;
a micro-controller
Main Unit
- a power
supply, the digital modulator/demodulator and the
Modem Unit
SU
Service Unit
EDI with up to 2 input and 2 output contacts, the output contacts supporting
relay; a digital service channel (DSC) based on E0 [G.703], codirectional;
an engineering order wire (EOW)
ETH TU
FU
Fan Unit
BP
Backplane
MU
Note: To plug in/retrieve a Modem Unit into/from an IDU will not interrupting the traffic
on the active Modem Unit.
EOW
DSC
EDI
E1
MUI MUI
(E1)
SU
CU(Core Unit)
Back Plane
IDU
I-MIS-F
I-MIS-TU-E1/T1
I-MIS-E3/T3
I-MIS-ETH
I-MIS-EOW
I-MIS-EDI
I-MIS-DSC
TU
(E1/E3;
T1/T3;
ETH)
I-CU-TU
SU
I-CU-SU
I-MIS-Q
CU (Core Unit)
FU
I-MIS-CU-MU
I-MIS-CU-MU
I-MIS-CU-MU & I-MIS-CU-FM
I-MIS-CU-FM
Back Plane
Mounting Hole
for Optional
Card
Connector for
Expanded SU
Connector for
Expanded Eth
TU
BDM
3.3V
RS- 232
3.3V
16*E1
16
POW
E1
1.8V
3.3V
LED
5*16
5
SPI
Rx_ Symb_Clk
System_Clk( LVDS)
spare
FPGA_ CONFG_SU
MUX_SU( LVDS)
Q
SMC
LED
2.5V
31
FEC
SPI
SCC
ODU_OOK_TX
ODU_OOK_RX
SCC
ODU_OOK_TX
ODU_OOK_RX
3.3V 1.2V
2
2
3
3
FPGA
CONFIG
CPU
MUX
FPGA_ CONFG_TU
MUX_TU( LVDS)
ETHSW
BDM
31
UTOPIA
MII
3.3V
&
5
12
5
DEMUX
SPI
NE Management
packet
5
12
SPI
HWID
SPI
SPI
SCC
SPI
SPI
I2C
SPI
I2C
5
5
10
10
2
SPI_TU
SPI_SU
SPI_MU
FU
CLK
IFCTRL
2
2
OPCTL
3
3
SSPRG
5
5
Local Bus
EPLD
Boot
SDRAM
Flash
Mounting Hole
MCLK
MIC-
PCM Codec
(PCM)
SPEAKER+
SPEAKER-
BCLKR/T
FSR/T
12
GND
Dx
Dr
DSC_D_IN+
DSC_IN1/2
DSC_D_INDSC_CK_IN+
DSC_CK_IN-
MUX Signal
Bus(LVTTL)
Receiver
V.11 PHY(PHY)
DSC_OUT1/2
DSC_D_OUT+
DSC_D_OUT-
Driver
DSC_CK_OUT+
DSC_CK_OUT-
12
LVDS
Transceiver
Interface and
driver(ID)
FPGA
CONFIG
SPI
5
FPGA CONFIG
Driver
SPI
Call_int
Call_out
EDI_IN1/2+
EDI_IN1/2-
EDI _OUT1/2a
EDI _OUT1/2com
EDI _OUT1/2b
Front Panel
Optical Coupler
(OC)
EDI_IN1/2
1.8V
3.3V
Relay
(REL)
DC-DC
(DC)
14
3.3V
5V
EDI_OUT1/2
CU Board
Mounting Hole
Int
10/100Base-T
Tx
10/100Base-T
Tx Framer
MII
10/100Base-T
10/100Base-T
Rx
Rx DeFramer
CLOCK
93M/12M
93M
330M
140M
A/D
D/A
IF
TRX
BP
INTFC
DSP
Cable
MUX
TX_OOK/RX_OOK
TELEMETRY
6V
5V
1.2V
3.3V
48V
DC-DC Converter
12V
Connector for
CU plug in
Connector for
MUA plug in
Connector for
FU plug in
Back Plane
I-CU-FU
I-FU-CU-MU
To FU
To CU
I-CU-MU
I-CU-MU
I-CU-MU
To MU B
To MU A
D-Sub44-Female
E1: CH1 - CH8
D-Sub44-Female
E1: CH9 CH16
IDU-Indoor Unit
Color
Green
Action
Meaning
Off
On
Red
Yellow
On
Slow Flashing The system have fault during booting, but not effect traffic.
Color
Green
MODEM
Red
Meaning
Off
On
On
Off
On
Red
On
Yellow
On
Green
ODU
Action
Label
Color
Action
Off
Meaning
The system is turn off.
The system is operating properly. No
On
Green
any alarm.
Slow Flashing The system is booting.
Major alarm, details need to check
On
through Web-CIT.
Core Unit ALARM/MAINT Red
The system have configuraion error
Slow Flashing
during booting.
Minor alarm, details need to check
On
through Web-CIT.
Yellow
The system have fault during booting,
Slow Flashing
but not effect traffic.
Label
MU
Modem Unit
ODU
Color
Action
Off
Green
On
On
Red
Fast Flashing
Meaning
The system is turn off.
The MU is operating properly
The MU has failed.
The modem is synchronizing.
In a protected system, the MU is in
On
redundant state.
Yellow
The redundant modem is
Fast Flashing
synchronizing.
Off
The ODU is absent.
Green
On
The ODU is operating properly.
Red
On
The ODU has failed.
In a protected system, the MU is in
Yellow
On
redundant state.
Explanation
The system have major alarm.
The system have minor alarm.
The remote system have alarm.
BER is above the threshold.
Indicates that a module is not inserted and powered in the
ODU A absent alarm
ODU A slot.
Indicates that a module is not inserted and powered in the
ODU B absent alarm
ODU B slot.
The system could not restore the configuration from the
Config file load failure alarm
config files; the default values were used.
Radio link failure alarm
The Rx demux cannot synchronize on main traffic.
Radio Network comm failure alarm The network communication over radio failed.
Switch over failure alarm
Switchover operation failed.
Temperature raised alarm
IDU operating tempreture is above threshold.
Indicates that a module is not inserted and powered in the
MU A absent alarm
MU A slot.
Indicates that a module is not inserted and powered in the
MU B absent alarm
MU B slot.
CU Card unknown alarm
There is an unknown card in CU slot.
CU FPGA config failure alarm
The CU FPGA download failed.
E1 TU Card unknown alarm
There is an unknown card in TU slot.
E1 TU FPGA config failure alarm
The TU FPGA download failed.
SU Card unknown alarm
There is an unknown card in SU slot.
SU FPGA config failue alarm
The SU FPGA download failed.
Alarm Level
Major
Minor
Minor
Major
Major
Major
Major
Major
Major
Major
Minor
Major
Major
Major
Major
Major
Major
Major
Major
Explanation
DSC inward loopback is set.
DSC line loopback is set.
External input 1 indicates an alarm condition.
External input 2 indicates an alarm condition.
There is an unknown card in MU A slot.
The MU A FPGA download failed.
The modem A Rx cannot synchronize on the incoming IF
signal.
CW-tone mode is set on Tx_A.
There is an unknown card in MU B slot.
The MU B FPGA download failed.
The modem B Rx cannot synchronize on the incoming IF
signal.
CW-tone mode is set on Tx_B.
ODU A is manually muted.
The ODU A software download failed.
The Tx A IF oscillator is not locked up.
The Rx A IF oscillator is not locked up.
The Tx A RF oscillator is not locked up.
The Rx A RF oscillator is not locked up.
The PA A output is low (more than 3 dB below the set
value).
The RSL of ODU A is below the system threshold.
The Tx A IF AGC is not locked up.
Alarm Level
Minor
Minor
Minor
Minor
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Explanation
DSC inward loopback is set.
The Rx A IF AGC is not locked up.
The ODU A's EEPROM is not functional.
The ODU A's power supply failed.
The ODU A's watch dog failed.
ODU B is manually muted.
The ODU B software download failed.
The Tx B IF oscillator is not locked up.
The Rx B IF oscillator is not locked up.
The Tx B RF oscillator is not locked up.
The Rx B RF oscillator is not locked up.
The PA B output is low (more than 3 dB below the set
value).
The RSL of ODU B is below the system threshold.
The Tx B IF AGC is not locked up.
The Rx B IF AGC is not locked up.
The ODU B's EEPROM is not functional.
The ODU B's power supply failed.
The ODU B's watch dog failed.
E1 tributary x: No input signal from the customer.
E1 tributary x input loopback is set.
E1 tributary x inward loopback is set.
Alarm Level
Minor
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
ODU A1
ODU A2
Independent of capacity
Small, compact, light
weight and aesthetic
easily blends into the
ODU A1
local environment.
ODU can be installed
ODU A2
either directly on \ with
the antenna or separately.
Antenna
Antenna
ODU A1
BNC
Ground bolt
Connector Type
Description
Ground bolt
Back loop
Feed source
Back loop
Feed source
ODU A2
BNC
Ground bolt
Connector Type
Description
Ground bolt
ODU A2 1+0
The two ODUs are coupled to the antenna side via a balanced or
unbalanced hybrid.
ATPC Operation
SW MODULES
SW Modules
IDU Software
Front
Panel
FTP
Client
Telnet
Client
DHCP
Client
SNTP
Server
SNMP
FTP
Server
Telnet
Server
DHCP
Server
SNTP
Client
Data Handler
Control Tasks
Hardware
TCP/IP
PPP
LAN
PPP Protocol
IP
IPCP
PPP
LCP
Framing
Radio interface
SW Modules
ODU Software
Alarm managerment
SC
Protocol handler
Hardware
SW Modules
Management Software
Management Web-CIT
Web-CIT Log in
Default settings
IP address: Obtain an IP address automatically
User name: admin
Password: admin
Link Installation
and Setup
Estimated values of RSL measured via the ODU BNC outlet (for A2)
Thank you