Air exhaust fan temperature

controlled designed

Louvre for incoming


air thermostatically
controlled with weather
protective lattice

Air exhaust fan temperature


controlled designed

Air exhaust fan temperature


controlled designed
Microactivated
carbon filter
combination

Air receiver

Air main
charging
system

Pressure
air pipe

2375

3200

1148
Screw
compressor

Refrigeration
dryer

Screw
compressor

Refrigeration
dryer

5900

800

To the
mains

Condensate
pipe

1530

Screw
compressor

887

800

887

Refrigeration
dryer

Control line

860

1150

11
2

6
i

Air reciver

1000

Screw
compressor

Condensate
treatment unit

800

Refrigeration
dryer

1116

500

ASD 35
ASD 40
ASD 50
ASD 60

Microactivated
carbon filter
combination

Air main
charging
system

To the
mains
ATTENTION!
Minimum width of door is total width of unit + 100 mm

Screw compressor
Hose line
Ball valve
Air receiver tank
Refrigeration dryer
Micofilter Activated Carbon combination
Compressormodel

759

Louvre for incoming air


thermostatically controled with
weather protective lattice

Oil
Water

Condensate line

1
2
3
4
5
6

759

6400

Refrigeration
dryer

Safety codes on site have to be


paid attention to.

Legend

A B

10

To the
mains
6

Screw
compressor

12

1150

400

300

1460

Drawings remain our exclusive property. They are entrusted only for the agreed purpose. Copies or any other reproduction, including storage, treatment and dissemination by use
of electronic systems must not be made for any other than the agreed purpose. Neither originals nor reproductions may be given to or made available to third parties.
Die Zeichnung bleibt unser ausschlieliches Eigentum. Sie wird nur zu dem vereinbarten Zweck anvertraut und darf zu keinem anderen Zweck verwendet werden. Kopien oder
sonstige Vervielfltigungen einschlielich Speicherung, Verarbeitung oder Verbreitung unter Verwendung elektronischer Systeme drfen nur zu dem vereinbarten Zweck angefertigt
werden. Weder Original noch Vervielfltigungen drfen Dritten ausgehndigt oder in sonstiger Weise zugnglich gemacht werden.

Design limits for


ambient temperature
min.:
+ 3 C
max.:
+ 40 C

B-B

A-A

7 Automatic condensate drain


8 Condensate Treatmente unit
9 Air main charging system
10 Hose coupling (Service AMCS)
11 Sigma Air Manager
12 Pressure transducer

Air entrance
Incomming
Compressed aperture m
air volume
air
free cross
m/ h per
connection section per
component
component
G 1 1/4
0,9
7190
G 1 1/4
1,2
8230
G 1 1/4
1,5
10270
G 1 1/4
1,7
12330

lines should
* Bypass
not be fitted on standby units

or when 100 % compressed air


quality is required.
The requirements of items 4 should be
chosen according operating conditions.

Air exhaust
fan m/ h

Minimum air
receiver
capacity l

ECODRAIN

14000
16000
20000
24000

1000
1000
2000
2000

12
12
12
12

** Designed for reference terms


ISO 7173 Option A

Air entrance
MicrofilterIncomming
Condensate
Refrigeration- Compressed aperture m
activated Compressed
air volume
treatment
dryer model
air
free cross
carbon
air
m/ h per
unit
**
connection section per
combination connection
component
AQUAMAT
component
model
TC 36
G 1 1/4
0,3
2400
FFG 48- D
R1
CF 19
TC 36
G 1 1/4
0,3
2400
FFG 48- D
R1
CF 19
TC 44
G 1 1/4
0,3
2400
FFG 48- D
R1
CF 19
TD 51
G 1 1/2
0,5
4000
FFG 71- D
R 1 1/2
CF 19

This drawing also contains work to be done on site. The regulations of EN 1012 & VDE 0100 have to be
observed; the requirements of existing operational safety ordinance and the manuals have to be considered
by the operator and the employer respectively at the place of installation.
The national safety and accident prevention regulations have to be observed.
The installation of a sub- assembly in terms of the pressure equipment directive 97/23/EC has to be carried
out according to this directive.
P+I
Scale
Date

Inst.

Template Rev. 02.03.2011

Sample Layout sketch

Description
Condensate lines have to be connected to a
collecting line via swan neck or are to be fed
to the condensate treatment system separately. 2x ASD with
A pressure-less drain has to be provided for.

exhaust air fan

Name

1:50

Drawn

28.11.2013 Langgu1

DIN A3

Checked

29.11.2013 Ernst

Plan No.

LYMU0004401e

Page 1 of 2

We reserve the right to make changes in the course of developement. This drawing can only be modified with CAD

Die Zeichnung bleibt unser ausschlieliches Eigentum. Sie wird nur zu dem vereinbarten Zweck anvertraut und darf zu keinem anderen Zweck verwendet werden. Kopien oder
sonstige Vervielfltigungen einschlielich Speicherung, Verarbeitung oder Verbreitung unter Verwendung elektronischer Systeme drfen nur zu dem vereinbarten Zweck angefertigt
werden. Weder Original noch Vervielfltigungen drfen Dritten ausgehndigt oder in sonstiger Weise zugnglich gemacht werden.

Drawings remain our exclusive property. They are entrusted only for the agreed purpose. Copies or any other reproduction, including storage, treatment and dissemination by use
of electronic systems must not be made for any other than the agreed purpose. Neither originals nor reproductions may be given to or made available to third parties.

Design limits for


ambient temperature
min.:
+ 3 C
max.:
+ 40 C

This drawing also contains work to be done on site. The regulations of EN 1012 & VDE 0100 have to be
observed; the requirements of existing operational safety ordinance and the manuals have to be considered
by the operator and the employer respectively at the place of installation.
The national safety and accident prevention regulations have to be observed.
The installation of a sub- assembly in terms of the pressure equipment directive 97/23/EC has to be carried
out according to this directive.
P+I
Scale
Date

Condensate lines have to be connected


to a collecting line via swan neck or are
to be fed to the oil/water separator
separately. A pressure-less drain has
to be provided for.

ATTENTION!
Minimum width of door is total width of unit + 100 mm
Safety codes on site have to be
paid attention to.

Inst.
Template Rev. 02.03.2011

Description

Sample Layout sketch

2x ASD with exhaust air fan

Name

1:50

Drawn

28.11.2013 Langgu1

DIN A3

Checked

29.11.2013 Ernst

Plan No.

LYMU0004401e

Page 2 of 2
We reserve the right to make changes in the course of developement. This drawing can only be modified with CAD

B-B

Recirculating air louvre


thermostatically controlled

Air exhaust fan temperature


controlled designed

Louvre for incoming


air thermostatically
controlled with weather
protective lattice

Air exhaust fan temperature


controlled designed
Louvre for outgoing air
thermostatically controlled with
weather protective lattice

Air receiver

Pressure
air pipe

Microfilter
Activated
Carbon combination

Air main
charging
system

2375
Screw
compressor

Screw
compressor

800

887

800

887

Refrigeration
dryer

Screw
compressor

Refrigeration
dryer

5900

To the
mains

Condensate
pipe

Refrigeration
dryer

Control line

860

1150

11

6
i

12

300

400

1460

1150

Air reciver

To the
mains
4

7
5

Screw
compressor

7
8

1000

Screw
compressor

Oil
Water

Condensate line

6400

759

Condensate
treatment unit

Legend
1
2
3
4
5
6

Screw compressor
Hose line
Ball valve
Air receiver tank
Refrigeration dryer
Micofilter Activated Carbon combination

Louvre for incoming air


thermostatically controled with
weather protective lattice

lines should
* Bypass
not be fitted on standby units

or when 100 % compressed air


quality is required.
The requirements of items 4 should be
chosen according operating conditions.

** Designed for reference terms


ISO 7173 Option A

759

Compressormodel

Refrigeration
dryer

1116

500

To the
mains

ASD 35
ASD 40
ASD 50
ASD 60

Microfilter
Activated
Carbon combination
Air main
charging
system

ATTENTION!
Minimum width of door is total width of unit + 100 mm
Safety codes on site have to be
paid attention to.

7 Automatic condensate drain


8 Condensate Treatmente unit
9 Air main charging system
10 Hose coupling (Service AMCS)
11 Sigma Air Manager
12 Pressure transducer

800

Refrigeration
dryer

A
B

10

1
Die Zeichnung bleibt unser ausschlieliches Eigentum. Sie wird nur zu dem vereinbarten Zweck anvertraut und darf zu keinem anderen Zweck verwendet werden. Kopien oder
sonstige Vervielfltigungen einschlielich Speicherung, Verarbeitung oder Verbreitung unter Verwendung elektronischer Systeme drfen nur zu dem vereinbarten Zweck angefertigt
werden. Weder Original noch Vervielfltigungen drfen Dritten ausgehndigt oder in sonstiger Weise zugnglich gemacht werden.

Design limits for


ambient temperature
min.:
+ 3 C
max.:
+ 40 C

3200

Drawings remain our exclusive property. They are entrusted only for the agreed purpose. Copies or any other reproduction, including storage, treatment and dissemination by use
of electronic systems must not be made for any other than the agreed purpose. Neither originals nor reproductions may be given to or made available to third parties.

A-A

Air entrance
Incomming
Compressed aperture m
air volume
air
free cross
m/ h per
connection section per
component
component
G 1 1/4
0,5
3990
G 1 1/4
0,6
4030
G 1 1/4
0,7
4770
G 1 1/4
0,8
5730

Permissible
Air exhaust
overall
Minimum air
duct
pressure loss
receiver
dimensions
for exhaust
capacity l
m
duct p
0,36
60
1000
0,36
60
1000
0,36
60
2000
0,36
40
2000

ECODRAIN
31
31
31
12

Air entrance
MicrofilterIncomming
Condensate
activated Compressed
Refrigeration- Compressed aperture m
air volume
treatment
dryer model
air
free cross
carbon
air
m/ h per
unit
**
connection section per
combination connection
component
AQUAMAT
component
model
TC 36
G 1 1/4
0,2
2380
FFG 48- D
R1
CF 19
TC 44
G 1 1/4
0,2
2380
FFG 48- D
R1
CF 19
TC 44
G 1 1/4
0,2
2380
FFG 48- D
R1
CF 19
TD 51
G 1 1/2
0,5
3960
FFG 71- D
R 1 1/2
CF 19

This drawing also contains work to be done on site. The regulations of EN 1012 & VDE 0100 have to be
observed; the requirements of existing operational safety ordinance and the manuals have to be considered
by the operator and the employer respectively at the place of installation.
The national safety and accident prevention regulations have to be observed.
The installation of a sub- assembly in terms of the pressure equipment directive 97/23/EC has to be carried
out according to this directive.
P+I
Scale
Date

Inst.

Template Rev. 02.03.2011


Condensate lines have to be connected to a
collecting line via swan neck or are to be fed Description Sample Layout
to the condensate treatment system separately. 2x ASD with exhaust duct
A pressure-less drain has to be provided for.

sketch

Name

1:50

Drawn

29.11.2013 Langgu1

DIN A3

Checked

29.11.2013 Ernst

Plan No.

LYMU0006101e

Page 1 of 2

We reserve the right to make changes in the course of developement. This drawing can only be modified with CAD

Die Zeichnung bleibt unser ausschlieliches Eigentum. Sie wird nur zu dem vereinbarten Zweck anvertraut und darf zu keinem anderen Zweck verwendet werden. Kopien oder
sonstige Vervielfltigungen einschlielich Speicherung, Verarbeitung oder Verbreitung unter Verwendung elektronischer Systeme drfen nur zu dem vereinbarten Zweck angefertigt
werden. Weder Original noch Vervielfltigungen drfen Dritten ausgehndigt oder in sonstiger Weise zugnglich gemacht werden.

Drawings remain our exclusive property. They are entrusted only for the agreed purpose. Copies or any other reproduction, including storage, treatment and dissemination by use
of electronic systems must not be made for any other than the agreed purpose. Neither originals nor reproductions may be given to or made available to third parties.

Design limits for


ambient temperature
min.:
+ 3 C
max.:
+ 40 C

This drawing also contains work to be done on site. The regulations of EN 1012 & VDE 0100 have to be
observed; the requirements of existing operational safety ordinance and the manuals have to be considered
by the operator and the employer respectively at the place of installation.
The national safety and accident prevention regulations have to be observed.
The installation of a sub- assembly in terms of the pressure equipment directive 97/23/EC has to be carried
out according to this directive.
P+I
Scale
Date

Condensate lines have to be connected


to a collecting line via swan neck or are
to be fed to the oil/water separator
separately. A pressure-less drain has
to be provided for.

ATTENTION!
Minimum width of door is total width of unit + 100 mm
Safety codes on site have to be
paid attention to.

Inst.
Template Rev. 02.03.2011

Description

Sample Layout sketch

2x ASD with exhaust duct

Name

1:50

Drawn

29.11.2013 Langgu1

DIN A3

Checked

29.11.2013 Ernst

Plan No.

LYMU0006101e

Page 2 of 2
We reserve the right to make changes in the course of developement. This drawing can only be modified with CAD

Drawings remain our exclusive property. They are entrusted only for the agreed purpose. Copies or any other reproduction, including storage, treatment and dissemination by use
of electronic systems must not be made for any other than the agreed purpose. Neither originals nor reproductions may be given to or made available to third parties.

Section A-A

Design limits for


ambient temperature
min.:
+ 3 C
max.:
+ 40 C

Section B-B
Air exhaust fan
thermostatically
controlled

Microfilteractivated carbon
combination

Microfilteractivated carbon
combination

Air
receiver

Air main
charging
system

To the
mains

1530

2390

Air
receiver

3500

Screw
compressor

Condensate
line

Screw
compressor

Control line for external pressure transducer

800

897

544

50

50

Condensate
treatment unit
AQUAMAT

To the
mains

Legend

Screw
compressor

1200

Microfilteractivated carbon
combination

350

600

250

Compressor
model
ASD 35 T
ASD 40 T
ASD 50 T
ASD 60 T

Air main
charging
system

3900

Water

Air
receiver

Louvre for incoming air


package controlled with
weather protective lattice

Air entrance
Compressed aperture m Incoming air
Air exhaust
air
free cross volume m/h
fan m/h
connection section per
per unit
unit
G 1 1/4
1,2
9190
9000
G 1 1/4
1,5
10230
10000
G 1 1/4
1,8
12270
12000
G 1 1/4
2
14330
14000

A
B

Oil

Condensate line

O 1150

1769

Die Zeichnung bleibt unser ausschlieliches Eigentum. Sie wird nur zu dem vereinbarten Zweck anvertraut und darf zu keinem anderen Zweck verwendet werden. Kopien oder
sonstige Vervielfltigungen einschlielich Speicherung, Verarbeitung oder Verbreitung unter Verwendung elektronischer Systeme drfen nur zu dem vereinbarten Zweck angefertigt
werden. Weder Original noch Vervielfltigungen drfen Dritten ausgehndigt oder in sonstiger Weise zugnglich gemacht werden.

Minimum air
receiver
capacity l
1000
1000
2000
2000

Screw compressor with integrated refrigeration dryer


Hose line
Ball valve
Microfilter- activated carbon combination
Pressure transducer
Air receiver
Air main charging system DHS
Hose coupling (Service DHS)
Condensate treatment unit

MicrofilterCondensate
activated Compressed
treatment
ECO- DRAIN
carbon
air
unit
combination connection
AQUAMAT
model
31
FFG- 48 D
R1
CF- 6
31
FFG- 48 D
R1
CF- 9
31
FFG- 48 D
R1
CF- 9
12
FFG- 71 D
R 1 1/2
CF- 9

This drawing also contains work to be done on site. The regulations of EN 1012 & VDE 0100 have to be
observed; the requirements of existing operational safety ordinance and the manuals have to be considered
by the operator and the employer respectively at the place of installation.
The national safety and accident prevention regulations have to be observed.
The installation of a sub- assembly in terms of the pressure equipment directive 97/23/EC has to be carried
out according to this directive.
P+I
Scale
Date

4100

Inst.
Condensate lines have to be connected
to a collecting line via swan neck or are
to be fed to the condensate treatment unit
separately. A pressure-less drain has
to be provided for.

1
2
3
4
5
6
7
8
9

ATTENTION!
Minimum width of door is total width of unit + 100 mm

Template Rev. 11.05.2012

Description

Sample layout sketch

1x ASD T with exhaust air fan

Name

1:50

Drawn

04.11.2013 blinzler1

DIN A3

Checked

04.11.2013 Ernst

Plan No.

LYMU0001203e

Page 1 of 2
We reserve the right to make changes in the course of developement. This drawing can only be modified with CAD

Design limits for


ambient temperature
min.:
+ 3 C
max.:
+ 40 C

Die Zeichnung bleibt unser ausschlieliches Eigentum. Sie wird nur zu dem vereinbarten Zweck anvertraut und darf zu keinem anderen Zweck verwendet werden. Kopien oder
sonstige Vervielfltigungen einschlielich Speicherung, Verarbeitung oder Verbreitung unter Verwendung elektronischer Systeme drfen nur zu dem vereinbarten Zweck angefertigt
werden. Weder Original noch Vervielfltigungen drfen Dritten ausgehndigt oder in sonstiger Weise zugnglich gemacht werden.

Drawings remain our exclusive property. They are entrusted only for the agreed purpose. Copies or any other reproduction, including storage, treatment and dissemination by use
of electronic systems must not be made for any other than the agreed purpose. Neither originals nor reproductions may be given to or made available to third parties.

1:20

This drawing also contains work to be done on site. The regulations of EN 1012 & VDE 0100 have to be
observed; the requirements of existing operational safety ordinance and the manuals have to be considered
by the operator and the employer respectively at the place of installation.
The national safety and accident prevention regulations have to be observed.

Condensate lines have to be connected


to a collecting line via swan neck or are
to be fed to the condensate treatment unit
separately. A pressure-less drain has
to be provided for.

ATTENTION!
Minimum width of door is total width of unit + 100 mm

The installation of a sub- assembly in terms of the pressure equipment directive 97/23/EC has to be carried
out according to this directive.
P+I
Scale
Date

Inst.
Template Rev. 02.03.2011

Description

Sample layout sketch

1x ASD T with exhaust air fan

1:50
DIN A2

Name

Drawn

04.11.2013 blinzler1

Checked

04.11.2013 Ernst

Plan No.

LYMU0001203e

Page 2 of 2
We reserve the right to make changes in the course of developement. This drawing can only be modified with CAD

Microfilteractivated
carbon
combination

Screw
compressor

Screw
compressor

Air exhaust fan


thermostatically
controlled with
weather protective
lattice

3500

Microfilteractivated
carbon
combination

Air
receiver
Condensate
line

To the
mains
Pressure
line

Condensate
treatment unit
AQUAMAT

Screw
compressor

Control line

10

5
7

To the
mains

Legend
1

6000
897

800

897

Condensate
treatment unit
AQUAMAT

Oil

Screw
compressor

Air
receiver

4100

Condensate line

O 1150

1769

Screw
compressor

1200

600

Microfilteractivated
carbon
combination

Air entrance
Compressed
Incomming
Compressoraperture m free
Air exhaust fan
air
air volume
model
cross section
m/h
connection
m/h per unit
per unit
ASD 35 T
ASD 40 T
ASD 50 T
ASD 60 T

G 1 1/4
G 1 1/4
G 1 1/4
G 1 1/4

SAM

Condensate lines have to be connected


to a collecting line via swan neck or are
to be fed to the condensate treatment unit
separately. A pressure-less drain has
to be provided for.

1,2
1,5
1,8
2

9190
10230
12270
14330

Water

Minimum air
receiver
capacity l

ECODRAIN

1000
1000
2000
2000

31
31
31
12

18000
20000
24000
28000

MicrofilterCondensate
activated carbon Compressed
treatment unit
combination
air connection
AQUAMAT
model
FFG- 48 D
FFG- 48 D
FFG- 48 D
FFG- 71 D

R1
R1
R1
R 1 1/2

CF- 19
CF- 19
CF- 19
CF- 19

This drawing also contains work to be done on site. The regulations of EN 1012 & VDE 0100 have to be
observed; the requirements of existing operational safety ordinance and the manuals have to be considered
by the operator and the employer respectively at the place of installation.
The national safety and accident prevention regulations have to be observed.

Air main
charging
system

Screw compressor with integrated


refrigeration dryer
Hose line
Ball valve
Microfilter- activated carbon combinat
Pressure transducer
Air receiver
Air main charging system DHS
Hose coupling (Service DHS)
Condensate treatment unit
Control SAM

2
3
4
5
6
7
8
9
10

250

6
4

800
Die Zeichnung bleibt unser ausschlieliches Eigentum. Sie wird nur zu dem vereinbarten Zweck anvertraut und darf zu keinem anderen Zweck verwendet werden. Kopien oder
sonstige Vervielfltigungen einschlielich Speicherung, Verarbeitung oder Verbreitung unter Verwendung elektronischer Systeme drfen nur zu dem vereinbarten Zweck angefertigt
werden. Weder Original noch Vervielfltigungen drfen Dritten ausgehndigt oder in sonstiger Weise zugnglich gemacht werden.

B-B

2402

Louvre for incoming air


package controlled with
weather protective lattice

1530

Drawings remain our exclusive property. They are entrusted only for the agreed purpose. Copies or any other reproduction, including storage, treatment and dissemination by use
of electronic systems must not be made for any other than the agreed purpose. Neither originals nor reproductions may be given to or made available to third parties.

A-A

Design limits for


ambient temperature
min.:
+ 3 C
max.:
+ 40 C

The installation of a sub- assembly in terms of the pressure equipment directive 97/23/EC has to be carried
out according to this directive.
P+I
Scale
Date

Inst.
ATTENTION!
Minimum width of door is total width of unit + 100 mm

Template Rev. 11.05.2012

Description

Sample layout sketch

2x ASD T with exhaust air fan

Name

1:50

Drawn

06.11.2013 blinzler1

DIN A3

Checked

06.11.2013 Ernst

Plan No.

LYMU0001402e

Page 1 of 2
We reserve the right to make changes in the course of developement. This drawing can only be modified with CAD

Die Zeichnung bleibt unser ausschlieliches Eigentum. Sie wird nur zu dem vereinbarten Zweck anvertraut und darf zu keinem anderen Zweck verwendet werden. Kopien oder
sonstige Vervielfltigungen einschlielich Speicherung, Verarbeitung oder Verbreitung unter Verwendung elektronischer Systeme drfen nur zu dem vereinbarten Zweck angefertigt
werden. Weder Original noch Vervielfltigungen drfen Dritten ausgehndigt oder in sonstiger Weise zugnglich gemacht werden.

Drawings remain our exclusive property. They are entrusted only for the agreed purpose. Copies or any other reproduction, including storage, treatment and dissemination by use
of electronic systems must not be made for any other than the agreed purpose. Neither originals nor reproductions may be given to or made available to third parties.

Design limits for


ambient temperature
min.:
+ 3 C
max.:
+ 40 C

This drawing also contains work to be done on site. The regulations of EN 1012 & VDE 0100 have to be
observed; the requirements of existing operational safety ordinance and the manuals have to be considered
by the operator and the employer respectively at the place of installation.
The national safety and accident prevention regulations have to be observed.
The installation of a sub- assembly in terms of the pressure equipment directive 97/23/EC has to be carried
out according to this directive.
P+I
Scale
Date

Condensate lines have to be connected


to a collecting line via swan neck or are
to be fed to the condensate treatment unit
separately. A pressure-less drain has
to be provided for.

ATTENTION!
Minimum width of door is total width of unit + 100 mm

Inst.
Template Rev. 11.05.2012

Description

Sample layout sketch

2x ASD T with exhaust air fan

Name

1:50

Drawn

06.11.2013 blinzler1

DIN A3

Checked

06.11.2013 Ernst

Plan No.

LYMU0001402e

Page 2 of 2
We reserve the right to make changes in the course of developement. This drawing can only be modified with CAD

Section B-B

Screw
compressor

To the
mains

2390

Air
receiver

Air main
charging
system

Microfilteractivated carbon
combination

Air exhaust fan


thermostatically
controlled

3500

Louvre for incoming air


package controlled with
weather protective lattice

Recirculating air louvre


thermostatically controlled

Louvre for outgoing air


thermostatically controlled
with weather protective lattice

Microfilteractivated carbon
combination

1530

Condensate
line

Screw
compressor

Control line for external pressure transducer

800

897

544

50
50

Drawings remain our exclusive property. They are entrusted only for the agreed purpose. Copies or any other reproduction, including storage, treatment and dissemination by use
of electronic systems must not be made for any other than the agreed purpose. Neither originals nor reproductions may be given to or made available to third parties.

Section A-A

Design limits for


ambient temperature
min.:
+ 3 C
max.:
+ 40 C

Condensate
treatment unit
AQUAMAT

To the
mains

Legend

350
1200

600

Microfilteractivated carbon
combination

Oil

Condensate line

250

Compressormodel

ASD 35 T
ASD 40 T
ASD 50 T
ASD 60 T

Air main
charging
system

3900

O 1150

Screw
compressor

Louvre for incoming air


package controlled with
weather protective lattice

Water

Air
receiver

1769

Die Zeichnung bleibt unser ausschlieliches Eigentum. Sie wird nur zu dem vereinbarten Zweck anvertraut und darf zu keinem anderen Zweck verwendet werden. Kopien oder
sonstige Vervielfltigungen einschlielich Speicherung, Verarbeitung oder Verbreitung unter Verwendung elektronischer Systeme drfen nur zu dem vereinbarten Zweck angefertigt
werden. Weder Original noch Vervielfltigungen drfen Dritten ausgehndigt oder in sonstiger Weise zugnglich gemacht werden.

Air entrance
Permissible
Compressed aperture m Incomming
overall pressure Exhaust air Minimum air
Air exhaust
air
free cross
air volume
loss for
fan for each
receiver
ECO- DRAIN
duct m
connection section per m/h per unit
exhaust air
dryer m/h
capacity l
unit
duct p
G 1 1/4
0,6
6030
0,36
60
2040
1000
31
G 1 1/4
0,7
6070
0,36
60
2040
1000
31
G 1 1/4
0,8
6810
0,36
60
2040
2000
31
G 1 1/4
0,9
7770
0,36
40
2040
2000
12

A
B

Screw compressor with integrated refrigeration dryer


Hose line
Ball valve
Microfilter- activated carbon combination
Pressure transducer
Air receiver
Air main charging system DHS
Hose coupling (Service DHS)
Condensate treatment unit

MicrofilterCondensate
activated Compressed
treatment
carbon
air
unit
combination connection
AQUAMAT
model
FFG- 48 D
R1
CF- 6
FFG- 48 D
R1
CF- 9
FFG- 48 D
R1
CF- 9
FFG- 71 D
R 1 1/2
CF- 9

This drawing also contains work to be done on site. The regulations of EN 1012 & VDE 0100 have to be
observed; the requirements of existing operational safety ordinance and the manuals have to be considered
by the operator and the employer respectively at the place of installation.
The national safety and accident prevention regulations have to be observed.
The installation of a sub- assembly in terms of the pressure equipment directive 97/23/EC has to be carried
out according to this directive.
P+I
Scale
Date

4100

Inst.
Condensate lines have to be connected
to a collecting line via swan neck or are
to be fed to the condensate treatment unit
separately. A pressure-less drain has
to be provided for.

1
2
3
4
5
6
7
8
9

ATTENTION!
Minimum width of door is total width of unit + 100 mm

Template Rev. 11.05.2012

Description

Sample layout sketch

1x ASD T with exhaust air duct

Name

1:50

Drawn

04.11.2013 blinzler1

DIN A3

Checked

04.11.2013 Ernst

Plan No.

LYMU0001302e

Page 1 of 2
We reserve the right to make changes in the course of developement. This drawing can only be modified with CAD

Design limits for


ambient temperature
min.:
+ 3 C
max.:
+ 40 C

Die Zeichnung bleibt unser ausschlieliches Eigentum. Sie wird nur zu dem vereinbarten Zweck anvertraut und darf zu keinem anderen Zweck verwendet werden. Kopien oder
sonstige Vervielfltigungen einschlielich Speicherung, Verarbeitung oder Verbreitung unter Verwendung elektronischer Systeme drfen nur zu dem vereinbarten Zweck angefertigt
werden. Weder Original noch Vervielfltigungen drfen Dritten ausgehndigt oder in sonstiger Weise zugnglich gemacht werden.

Drawings remain our exclusive property. They are entrusted only for the agreed purpose. Copies or any other reproduction, including storage, treatment and dissemination by use
of electronic systems must not be made for any other than the agreed purpose. Neither originals nor reproductions may be given to or made available to third parties.

1:20

This drawing also contains work to be done on site. The regulations of EN 1012 & VDE 0100 have to be
observed; the requirements of existing operational safety ordinance and the manuals have to be considered
by the operator and the employer respectively at the place of installation.
The national safety and accident prevention regulations have to be observed.

Condensate lines have to be connected


to a collecting line via swan neck or are
to be fed to the condensate treatment unit
separately. A pressure-less drain has
to be provided for.

ATTENTION!
Minimum width of door is total width of unit + 100 mm

The installation of a sub- assembly in terms of the pressure equipment directive 97/23/EC has to be carried
out according to this directive.
P+I
Scale
Date

Inst.
Template Rev. 02.03.2011

Description

Sample layout sketch

1x ASD T with exhaust air duct

1:50
DIN A2

Name

Drawn

04.11.2013 blinzler1

Checked

04.11.2013 Ernst

Plan No.

LYMU0001302e

Page 2 of 2
We reserve the right to make changes in the course of developement. This drawing can only be modified with CAD

Condensate
line

Screw
compressor

Air exhaust fan


thermostatically
controlled

3500
Air
receiver

To the
mains
Pressure
line

Condensate
treatment unit
AQUAMAT

Screw
compressor

Control line

10

5
7

To the
mains

897

800

Legend
1

6000
897

Condensate
treatment unit
AQUAMAT

1200

600

Microfilteractivated
carbon
combination

Screw compressor with integrated


refrigeration dryer
Hose line
Ball valve
Microfilter- activated carbon combinat
Pressure transducer
Air receiver
Air main charging system DHS
Hose coupling (Service DHS)
Condensate treatment unit
Control SAM

2
3
4
5
6
7
8
9
10

250

6
4

800

Oil

Screw
compressor

Air
receiver

4100

Screw
compressor

O 1150

Condensate line

1769

Die Zeichnung bleibt unser ausschlieliches Eigentum. Sie wird nur zu dem vereinbarten Zweck anvertraut und darf zu keinem anderen Zweck verwendet werden. Kopien oder
sonstige Vervielfltigungen einschlielich Speicherung, Verarbeitung oder Verbreitung unter Verwendung elektronischer Systeme drfen nur zu dem vereinbarten Zweck angefertigt
werden. Weder Original noch Vervielfltigungen drfen Dritten ausgehndigt oder in sonstiger Weise zugnglich gemacht werden.

Microfilteractivated
carbon
combination

Microfilteractivated
carbon
combination

B-B

Design limits for


ambient temperature
min.:
+ 3 C
max.:
+ 40 C

Louvre for recirculation air


thermostatically controlled

2402

Louvre for incoming air


package controlled with
weather protective lattice

1530

Drawings remain our exclusive property. They are entrusted only for the agreed purpose. Copies or any other reproduction, including storage, treatment and dissemination by use
of electronic systems must not be made for any other than the agreed purpose. Neither originals nor reproductions may be given to or made available to third parties.

A-A

Louvre for outgoing air


thermostatically controlled
with weather protective lattice

SAM

Condensate lines have to be connected


to a collecting line via swan neck or are
to be fed to the condensate treatment unit
separately. A pressure-less drain has
to be provided for.

Exhaust air
fan for each
dryer m/h

Minimum air
receiver
capacity l

ECODRAIN

2040
2040
2040
2040

1000
1000
2000
2000

31
31
31
12

MicrofilterCondensate
Compressed
activated
treatment
carbon
air
unit
combination connection
AQUAMAT
model
FFG- 48 D
R1
CF- 19
FFG- 48 D
R1
CF- 19
FFG- 48 D
R1
CF- 19
FFG- 71 D
R 1 1/2
CF- 19

This drawing also contains work to be done on site. The regulations of EN 1012 & VDE 0100 have to be
observed; the requirements of existing operational safety ordinance and the manuals have to be considered
by the operator and the employer respectively at the place of installation.
The national safety and accident prevention regulations have to be observed.

Air main
charging
system

Water

Permissible
Air entrance
Air exhaust duct
Compressed aperture m Incomming
overall
Compressordimensions m
pressure loss
air
free cross
air volume
model
(free cross
for exhaust air
connection section per m/h per unit
section)
unit
duct p Pa
ASD 35 T
G 1 1/4
0,6
6030
0,36
60
ASD 40 T
G 1 1/4
0,7
6070
0,36
60
ASD 50 T
G 1 1/4
0,8
6810
0,36
60
ASD 60 T
G 1 1/4
0,9
7770
0,36
40

The installation of a sub- assembly in terms of the pressure equipment directive 97/23/EC has to be carried
out according to this directive.
P+I
Scale
Date

Inst.
ATTENTION!
Minimum width of door is total width of unit + 100 mm

Template Rev. 11.05.2012

Description

Sample layout sketch

2x ASD T with exhaust air duct

Name

1:50

Drawn

05.11.2013 blinzler1

DIN A3

Checked

05.11.2013 Ernst

Plan No.

LYMU0001502e

Page 1 of 2
We reserve the right to make changes in the course of developement. This drawing can only be modified with CAD

Die Zeichnung bleibt unser ausschlieliches Eigentum. Sie wird nur zu dem vereinbarten Zweck anvertraut und darf zu keinem anderen Zweck verwendet werden. Kopien oder
sonstige Vervielfltigungen einschlielich Speicherung, Verarbeitung oder Verbreitung unter Verwendung elektronischer Systeme drfen nur zu dem vereinbarten Zweck angefertigt
werden. Weder Original noch Vervielfltigungen drfen Dritten ausgehndigt oder in sonstiger Weise zugnglich gemacht werden.

Drawings remain our exclusive property. They are entrusted only for the agreed purpose. Copies or any other reproduction, including storage, treatment and dissemination by use
of electronic systems must not be made for any other than the agreed purpose. Neither originals nor reproductions may be given to or made available to third parties.

Design limits for


ambient temperature
min.:
+ 3 C
max.:
+ 40 C

This drawing also contains work to be done on site. The regulations of EN 1012 & VDE 0100 have to be
observed; the requirements of existing operational safety ordinance and the manuals have to be considered
by the operator and the employer respectively at the place of installation.
The national safety and accident prevention regulations have to be observed.
The installation of a sub- assembly in terms of the pressure equipment directive 97/23/EC has to be carried
out according to this directive.
P+I
Scale
Date

Condensate lines have to be connected


to a collecting line via swan neck or are
to be fed to the condensate treatment unit
separately. A pressure-less drain has
to be provided for.

ATTENTION!
Minimum width of door is total width of unit + 100 mm

Inst.
Template Rev. 11.05.2012

Description

Sample layout sketch

2x ASD T with exhaust air duct

Name

1:50

Drawn

05.11.2013 blinzler1

DIN A3

Checked

05.11.2013 Ernst

Plan No.

LYMU0001502e

Page 2 of 2
We reserve the right to make changes in the course of developement. This drawing can only be modified with CAD