Sie sind auf Seite 1von 49

LICENCE

for
AS 1926.1-2012 Swimming pool safety - Safety barriers for swimming pools

Licensee:

Mr Ken Bridges

Date:

Wednesday, 23 April 2014 12:32 PM

Licence Agreement
This is an agreement between the end user of the Product ("Licensee") and SAI Global Limited, 286 Sussex Street, Sydney
NSW 2000 AUSTRALIA, ABN 67 050 611 642.
1. Definitions and Interpretations
Australian Standards means Australian Standards and includes Joint ISO/Australian Standards, Joint NZ/Australian Standards,
current Draft Australian Standards, and amendments to Australian Standards.
Concurrent Users means the maximum number of people able to access the Product at any one time, and is limited to the
number of Licences purchased.
ISO Standards means Standards published by the International Organization for Standardization (ISO), for which SAI Global is
an authorised distributor.
IEC Standards means Standards published by the International Electrotechnical Commission (IEC), for which SAI Global is an
authorised distributor.
Internal use means use of the Product within the Licensees organization.
Licence means the right to access and use the Product.
Licensee means the purchaser and user of the Product.
Product means Australian Standards, ISO Standards and IEC Standards ordered and purchased through the infostore, and
downloaded as electronic PDF files.
Click on the red box above to activate the Licence Agreement scroll bar.

2. Product Availability

See publications
the same
Subject
2.1. The Product is available
via the World covering
Wide Web through
the use
of a web Area
browser. Documents are provided as PDF files,
viewable through the use of the latest version of Adobe Reader.
Subscribe to our Free Newsletters about Australian Standards in
ISO, IEC, BSI and more

3. Licence Agreement
Legislation;

3.1. By using the Product


thehow
Licensee
agrees to be
bound by theCollections
Licence Agreement
for the Product.
Learn
to Manage
Standards
Online
3.2. The Licensee isLearn
grantedabout
a non-exclusive
and non-assignable
Licence to use
the Product.
LexConnect,
All Jurisdictions,
Standards
referenced

in

Australian legislation

3.3. Licensees are permitted to use the Product the following extent:

Know when a Standard has changed

3.3.a. PDF (Personal Use) Format - Purchasers of personal user Licences for the PDF format of the publication may locally
install and use the publication
theSAI
number
of individual
computers
corresponding
Affiliate to the Quantity specified in the SAI Global
Becomeonan
Global
Standards
Sales
Infostore order. Licensees are permitted to print once for Internal use limited to the Quantity specified in the SAI Global Infostore
order only (excludes electronic pads of forms). Licensees are permitted to store one electronic version of the publication for
Representing hundreds of Standards bodies including:
backup purposes.
For reproduction of the PDF (Personal Use) publication or portions thereof, and for which are outside the circumstances included
in this agreement, permission must be sought in writing from SAI Global, Copyright Officer at copyright@saiglobal.com.
3.3.b. PDF (Copy/Paste) Format - Purchasers of personal user Licences for the PDF(copy/paste) format of the publication may
locally install and use the publication on the number of individual computers corresponding to the Quantity specified in the SAI
Global Infostore order. Licensees are permitted to print once for Internal use limited to the Quantity specified in the SAI Global
Infostore order only (excludes electronic pads of forms). Licensees are permitted to store one electronic version of the publication

AS 1926.12012

Licensed to Mr Ken Bridges on 23 April 2014. 1 user personal license only. Copying, copy/pasting, storage & distribution or use on network prohibited. (10459277).
Get permission to copy from or network this publication www.saiglobal.com/licensing

AS 1926.12012

Australian Standard

Swimming pool safety

Part 1: Safety barriers for swimming


pools

Licensed to Mr Ken Bridges on 23 April 2014. 1 user personal license only. Copying, copy/pasting, storage & distribution or use on network prohibited. (10459277).
Get permission to copy from or network this publication www.saiglobal.com/licensing

This Australian Standard was prepared by Committee CS-034, Safety of Private Swimming
Pools. It was approved on behalf of the Council of Standards Australia on 18 September
2012.
This Standard was published on 6 November 2012.

The following are represented on Committee CS-034:

Australian Building Codes Board


Australian Competition and Consumer Commission
Australian Industry Group
Australian Institute of Building Surveyors
Building Codes Queensland
Bureau of Steel Manufacturers of Australia
Consumers Federation of Australia
Kidsafe
NSW Department of Health
NSW Office of Fair Trading
Planning South Australia
Royal Life Saving Society Australia
Swimming Pool and Spa Association of NSW
Swimming Pool and Spa Association of Western Australia
Swimming Pool and Spa Association of Victoria

This Standard was issued in draft form for comment as DR2 AS 1926.1.
Standards Australia wishes to acknowledge the participation of the expert individuals that
contributed to the development of this Standard through their representation on the
Committee and through the public comment period.

Keeping Standards up-to-date


Australian Standards are living documents that reflect progress in science, technology and
systems. To maintain their currency, all Standards are periodically reviewed, and new editions
are published. Between editions, amendments may be issued.
Standards may also be withdrawn. It is important that readers assure themselves they are
using a current Standard, which should include any amendments that may have been
published since the Standard was published.
Detailed information about Australian Standards, drafts, amendments and new projects can
be found by visiting www.standards.org.au
Standards Australia welcomes suggestions for improvements, and encourages readers to
notify us immediately of any apparent inaccuracies or ambiguities. Contact us via email at
mail@standards.org.au, or write to Standards Australia, GPO Box 476, Sydney, NSW 2001.

Licensed to Mr Ken Bridges on 23 April 2014. 1 user personal license only. Copying, copy/pasting, storage & distribution or use on network prohibited. (10459277).
Get permission to copy from or network this publication www.saiglobal.com/licensing

AS 1926.12012

Australian Standard
Swimming pool safety
Part 1: Safety barriers for swimming
pools

Originated as AS 19261976 and AS 28201985.


Previous editions AS 1926.12007 and AS 28201993.
Revised, amalgamated and redesignated as AS 1926.12012.

COPYRIGHT
Standards Australia Limited
All rights are reserved. No part of this work may be reproduced or copied in any form or by
any means, electronic or mechanical, including photocopying, without the written
permission of the publisher, unless otherwise permitted under the Copyright Act 1968.
Published by SAI Global Limited under licence from Standards Australia Limited, GPO Box
476, Sydney, NSW 2001, Australia
ISBN 978 1 74342 253 3

AS 1926.12012

Licensed to Mr Ken Bridges on 23 April 2014. 1 user personal license only. Copying, copy/pasting, storage & distribution or use on network prohibited. (10459277).
Get permission to copy from or network this publication www.saiglobal.com/licensing

PREFACE
This Standard was prepared by the Standards Australia Committee CS-034, Safety of
Private Swimming Pools, to supersede AS 1926.12007, Swimming pool safety, Part 1:
Safety barriers for swimming pools, and AS 28201993, Gate units for private swimming
pools.
The objective of this Standard is to assist pool owners/users in avoiding pool-related
drowning by providing design, construction and performance of various barrier options,
which are designed to restrict entry to the swimming pool area by young children.
This Standard is part of a series dealing with barriers, location of barriers and water
recirculation and filtration systems for swimming pools, as follows.
AS
1926
1926.1
1926.2
1926.3

Swimming pool safety


Part 1: Safety barriers for swimming pools (this Standard)
Part 2: Location of safety barriers for swimming pools
Part 3: Water recirculation systems

This revision incorporates changes to the previous edition to correct and clarify many
inconsistencies and areas of ambiguity. Technical and diagrammatic errors have been
corrected to clarify particular safety issues. Glass barriers have been included for the first
time.
This revision also incorporates the requirements for the design, construction and
performance of gate units installed as part of a barrier from AS 2820, Gate units for private
swimming pools.
Statistical evidence shows that the majority of drowning deaths in private swimming pools
involve children under five years of age. For this reason, the requirements established by
this Standard are directed at achieving a barrier that will make it difficult for a young child
to gain access to a pool area, whether under, over or through the barrier.
It should be noted that the provisions of this Standard relate to barriers that are intended to
be child resistant but not childproof, as effectiveness of the barrier is very much dependent
on its location, installation and maintenance.
The requirements are established with the intention of leaving a high degree of flexibility to
the consumer in the choice of barrier, desirable aesthetics and cost.
Requirements for the effective use of barriers in protecting children from pool hazards are
given in AS 1926.2, Swimming pool safety, Part 2: Location of safety barriers for swimming
pools.
In the development of this Standard reference was made to the Queensland Development
Code (QDC).
The terms normative and informative have been used in this Standard to define the
application of the appendix to which they apply. A normative appendix is an integral part
of the Standard, whereas in an informative appendix is only for information and guidance.
Notes to the text contain information and guidance. They are not an integral part of the
Standard.

AS 1926.12012

Licensed to Mr Ken Bridges on 23 April 2014. 1 user personal license only. Copying, copy/pasting, storage & distribution or use on network prohibited. (10459277).
Get permission to copy from or network this publication www.saiglobal.com/licensing

CONTENTS
Page
SECTION 1 SCOPE AND GENERAL
1.1 SCOPE ......................................................................................................................... 4
1.2 NORMATIVE REFERENCES .................................................................................... 4
1.3 DEFINITIONS............................................................................................................. 4
SECTION 2 DESIGN AND CONSTRUCTION OF ELEMENTS OF A BARRIER
2.1 GENERAL ................................................................................................................... 7
2.2 NON-CLIMBABLE ZONE (NCZ) .............................................................................. 7
2.3 BARRIERS ................................................................................................................ 12
2.4 GATES, GATE UNITS AND LATCH FITTINGS .................................................... 17
2.5 OTHER BARRIERS .................................................................................................. 21
2.6 CHILD-RESISTANT OPENABLE PORTION OF WINDOW .................................. 23
2.7 CHILD RESISTANT DOORSETS ............................................................................ 24
2.8 BALCONY BALUSTRADES ................................................................................... 25
2.9 ABOVE-GROUND POOLS ...................................................................................... 25
SECTION 3 LOADING REQUIREMENTS
3.1 STRENGTH AND RIGIDITY OF OPENINGS ......................................................... 26
3.2 STRENGTH OF POSTS AND FOOTINGS .............................................................. 26
3.3 STRENGTH OF BARRIER COMPONENTS............................................................ 26
3.4 CLOSING AND LATCHING OF GATES ................................................................ 26
3.5 DURABILITY OF A GATE UNIT ........................................................................... 27
APPENDICES
A
TEST FOR STRENGTH AND RIGIDITY OF BARRIER OPENINGS .................... 28
B
STRENGTH TEST FOR POSTS AND FOOTINGS.................................................. 32
C
STRENGTH TEST FOR RIGID BARRIER COMPONENTS ................................... 34
D
STRENGTH TEST FOR FLEXIBLE MATERIALS AND COMPONENTS ............ 36
E
STRENGTH TEST FOR RIGID COMPONENTS OF GATE UNITS ...................... 38
F
TEST OF DURABILITY OF GATE UNITS ............................................................ 40

AS 1926.12012

STANDARDS AUSTRALIA

Licensed to Mr Ken Bridges on 23 April 2014. 1 user personal license only. Copying, copy/pasting, storage & distribution or use on network prohibited. (10459277).
Get permission to copy from or network this publication www.saiglobal.com/licensing

Australian Standard
Swimming pool safety
Part 1: Safety barriers for swimming pools

S E C T I O N

S C O P E

A N D

G E N E R A L

1.1 SCOPE
This Standard specifies requirements for the design, construction and performance of
barriers that will restrict the access of young children to swimming pools.
NOTE: Public swimming pools have different human dynamics, such as access for people with
disabilities, increased gate usage, crowd behaviour and supervision, and the duplication of the
requirements of this Standard may not always be appropriate.

1.2 NORMATIVE REFERENCES


The following are the normative documents referred to in this Standard:
NOTE: Documents referenced for informative purposes are listed in the Bibliography.

AS
1288

Glass in buildingsSelection and installation

1.3 DEFINITIONS
For the purpose of this Standard, the definitions below apply.
1.3.1 Barrier
The assembly of components, natural or otherwise, that restricts access to the pool. The
barrier includes items such as fences, posts and panels, gate units, gates and doorsets,
constructed or natural walls retaining or otherwise, sides of buildings, and balustrades on a
balcony, where they form part of the intended barrier.
1.3.2 Barrier height
The height of the barrier perpendicular to the finished ground level.
1.3.3 Boundary barrier
A dividing barrier between two adjoining properties.
1.3.4 Child-resistant doorset
A barrier installed in a residential building that comprises a door, door frame, self-closing
device and latch.
1.3.5 Child-resistant windows
The opening part of a window that is protected in accordance with Clause 2.6.
1.3.6 Finished ground level (FGL)
Ground level or other permanent stable surface.

Standards Australia

www.standards.org.au

AS 1926.12012

1.3.7 Flexible components

Licensed to Mr Ken Bridges on 23 April 2014. 1 user personal license only. Copying, copy/pasting, storage & distribution or use on network prohibited. (10459277).
Get permission to copy from or network this publication www.saiglobal.com/licensing

Flexible components are those parts of a barrier or materials used in a barrier made with
chain link wire mesh, perforated materials, fabric, brushwood and the like.
1.3.8 Foothold
A component of, or feature in, an NCZ that can be used by a young child as an aid to
climbing a barrier.
1.3.9 Gate
A portion of a barrier, other than a child-resistant doorset that is designed to provide access
through the barrier.
1.3.10 Gate unit
An assembly comprising a gate, a hinge post, a latch post, a latching device, hinges and a
self-closing device.
1.3.11 Handhold
A component of, or feature in, an NCZ that can be used by a young child as an aid to
climbing a barrier.
1.3.12 Indoor pool
A pool that is fully enclosed within a residential building or by a separate building.
1.3.13 Indoor/outdoor pool
A pool that is partly enclosed by a building and partly an outdoor pool.
1.3.14 Latch
A self-latching mechanism that prevents the opening of a closed gate or door without
activation of its release device.
1.3.15 Non-climbable
A part of a barrier in which there are no handholds or footholds or other aids for climbing.
1.3.16 Non-climbable zone (NCZ)
A zone on a barrier and in the space adjacent to a barrier, running the full length of a barrier
including a gate, that is intended to restrict climbing of the barrier by young children.
1.3.17 Outdoor pool
A pool that is not fully or partly enclosed by a building.
1.3.18 Outside of the barrier
That side of a barrier facing away from the pool area.
1.3.19 Permanent structure
A barrier, or part of a barrier which cannot be removed without the use of tools.
1.3.20 Pool area
The area that contains the pool and is enclosed by a barrier.
1.3.21 Rigid components
Rigid components of a barrier are those made of steel, aluminium, wood, glass, acrylic,
masonry and the like.
1.3.22 Swimming pool (referred to as pool in this Standard)
Any structure containing water to a depth greater than 300 mm and used primarily for
swimming, wading, paddling or the like, including a bathing or wading pool, or spa pool.
www.standards.org.au

Standards Australia

AS 1926.12012

1.3.23 Tool (tools)


Screwdriver, spanner, wrench, shovel, cutting implement or the like.

Licensed to Mr Ken Bridges on 23 April 2014. 1 user personal license only. Copying, copy/pasting, storage & distribution or use on network prohibited. (10459277).
Get permission to copy from or network this publication www.saiglobal.com/licensing

1.3.24 Within the property


On a property other than on a property boundary.
1.3.25 Young child
A child under the age of five years.

Standards Australia

www.standards.org.au

AS 1926.12012

Licensed to Mr Ken Bridges on 23 April 2014. 1 user personal license only. Copying, copy/pasting, storage & distribution or use on network prohibited. (10459277).
Get permission to copy from or network this publication www.saiglobal.com/licensing

S E C T I O N 2
D E S I G N A N D C O N S T R UC T I O N
O F E L E M E N T S O F A B A R R I E R
2.1 GENERAL
A barrier shall be designed and constructed so that it will restrict access by young children.
The barrier shall be a permanent structure.
The height of a barrier within the property shall be not less than 1200 mm on the outside of
the barrier.
Barriers may be constructed from any durable material, provided the barrier complies with
the requirements of this Standard.
A barrier other than a retaining wall, shall be vertical or lean away from the pool by not
more than 15.
NOTE: A barrier should be free of sharp edges, sharp projections, and similar hazards.

2.2 NON-CLIMBABLE ZONE (NCZ)


2.2.1 General
The height and radius of the arc of all NCZs (other than NCZ 4) shall be not less than
900 mm. Within an NCZ there shall be no handholds or footholds, objects or plants that will
facilitate climbing.
Where NCZs are required they shall apply to the entire length of a barrier.
2.2.2 Barriers less than 1800 mm in height
The following NCZs shall be present on all barriers with a height less than 1800 mm:
(a)

NCZ 1 is a 900 mm vertical plane on the outside face of a barrier. This NCZ may be
located anywhere within the perpendicular height of a barrier or, where present,
anywhere between horizontal components or handholds and footholds on a barrier
(see Figures 2.1, 2.3, 2.5 to 2.8, and 2.10 (b) and (c)).

(b)

NCZ 2 is a quadrant on the outside of a barrier created by a 900 mm radius down


from the top of NCZ 1 above (see Figures 2.1, 2.3, 2.6 and 2.10 (b) and (c)).
NOTE: NCZ 2 is always immediately adjacent to NCZ 1 on all barriers.

(c)

NCZ 3 is a quadrant on the outside of a barrier created by a 900 mm radius up from


the top of the barrier. When the top of NCZ 1 is below the top of a barrier then NCZ 3
shall extend vertically down to the top of NCZ 1 (see Figures 2.1 and 2.11). NCZ 3 is
applicable only to the space created by the quadrant and does not apply to any item or
component on, or that is part of, the barrier.

(d)

NCZ 4 is required on all barriers with vertical openings 10100 mm in width and is a
900 mm high by 300 mm deep rectangular space on the inside of the barrier and shall
align with NCZ 1 (see Figures 2.1 and 2.6).

A barrier component or an item or object on a barrier that would otherwise be climbable is


non-climbable if its top surface is sloped at more than 60 to the horizontal plane (see
Figure 2.6).

www.standards.org.au

Standards Australia

AS 1926.12012

90

OUTSIDE

OUTSIDE
300

N CZ 3

N CZ 2

90

I N S ID E

Ba r r ie r
FG L

S te p
50 0 min.

(a) N CZ 2 at top of ba r r i e r

NCZ
4

0
120 0 m i n.

NCZ
4

120 0 m i n.

I N S ID E

90

N CZ 3

90

Licensed to Mr Ken Bridges on 23 April 2014. 1 user personal license only. Copying, copy/pasting, storage & distribution or use on network prohibited. (10459277).
Get permission to copy from or network this publication www.saiglobal.com/licensing

300

N CZ 2

Ba r r ie r
FG L
( b) N CZ 2 in mi d dl e of ba r r i e r

NOT E: T he lowe r r a d iu s p oi nt of NCZ 2 m ay b e lo cat e d a ny whe re on t he ba r r ie r


prov ide d t he re a re no a id s for cl i mbi ng w it h i n t he a rc.
DIMENSIONS IN MILLIMETRES

FIGURE 2.1 (in part) EXAMPLES OF NON-CLIMBABLE ZONES (NCZs)

Standards Australia

www.standards.org.au

AS 1926.12012

Licensed to Mr Ken Bridges on 23 April 2014. 1 user personal license only. Copying, copy/pasting, storage & distribution or use on network prohibited. (10459277).
Get permission to copy from or network this publication www.saiglobal.com/licensing

N CZ 3

R efe r to
Cl a u s e 2. 2. 2(c)

N CZ 4
H e i g ht
120 0 m i n.

300

R 900

N CZ 2

R 900

N CZ 1 o u t s i d e fa c e

50 0 min.

(c) 3 D vi ew of N CZ s
DIMENSIONS IN MILLIMETRES

FIGURE 2.1 (in part) EXAMPLES OF NON-CLIMBABLE ZONES (NCZs)

2.2.3 Barriers not less than 1800 mm in height


Barriers not less than 1800 mm in height shall not require an NCZ and may be climbable on
either or both sides.
2.2.4 Boundary barriers
Where a boundary fence acts as a barrier to a pool, it shall have a height not less than
1800 mm on the inside and NCZ 5 formed as a quadrant of 900 mm radius down from the
top of the inside of the barrier. See Figure 2.2(a). The following also apply:
(a)

NCZ 5 is not invalidated by the intersection of a compliant internal fence provided


the width of the top rail or surface of the intersecting barrier is not more than 50 mm
wide at any point within the non-climbable zone and intersects at an angle of between
45 and 135 degrees to the 1800 mm boundary barrier (see Figure 2.2(b)).

(b)

Where the top rail or surface of the internal barrier is greater than 50 mm and is
located within the NCZ 5, the height of the lower barrier shall extend to a height not
less than 1800 mm and extend not less than 900 mm from the intersection
(see Figure 2.2(c)).

www.standards.org.au

Standards Australia

10

90

Licensed to Mr Ken Bridges on 23 April 2014. 1 user personal license only. Copying, copy/pasting, storage & distribution or use on network prohibited. (10459277).
Get permission to copy from or network this publication www.saiglobal.com/licensing

AS 1926.12012

I N S ID E
1800 min.

N CZ 5

OUTSIDE
(may b e
climbable)

Ba r r ie r
FG L

(a) Bounda r y ba r r ie r 18 0 0 mm min.

Barrier
To p p a r t of
barrier maximum
50 mm wide

Barrier

S e e D e t a il A T hi s b a r r i e r m u s t i nte r s e c t
at a a n g l e of b e t we e n 4 5 a n d 13 5 to
th e 18 0 0 m m hi g h b a r r i e r

I n te r s e c t i n g
barrier within the
9 0 0 m m N CZ

D E TA IL A

( b) Inte r s e c ti n g b a r r i e r wi th to p l e s s th a n 50 m m i n wi d th
DIMENSIONS IN MILLIMETRES

FIGURE 2.2 (in part) BOUNDARY BARRIERS

Standards Australia

www.standards.org.au

Licensed to Mr Ken Bridges on 23 April 2014. 1 user personal license only. Copying, copy/pasting, storage & distribution or use on network prohibited. (10459277).
Get permission to copy from or network this publication www.saiglobal.com/licensing

11

AS 1926.12012

Boundar y barrier

I n te r n a l b a r r i e r

F.G .L .

(c) Inte r s e c ti n g b a r r i e r wi th to p g r e ate r th a n 50 m m i n wi d th

DIMENSIONS IN MILLIMETRES

FIGURE 2.2 (in part)

BOUNDARY BARRIERS

2.2.5 Intersecting barriers


Where a barrier with a height less than 1800 mm intersects with a barrier with a height not
less than 1800 mm at an angle greater than 90 then NCZs 1 and 2 on the lower barrier shall
extend 900 mm beyond that intersection (see Figure 2.3).

www.standards.org.au

Standards Australia

Licensed to Mr Ken Bridges on 23 April 2014. 1 user personal license only. Copying, copy/pasting, storage & distribution or use on network prohibited. (10459277).
Get permission to copy from or network this publication www.saiglobal.com/licensing

AS 1926.12012

12

More than 90

More than 90

DIMENSIONS IN MILLIMETRES

FIGURE 2.3 INTERSECTING INTERNAL BARRIERS

2.3 BARRIERS
2.3.1 Features and objects near a barrier
In addition to the provisions of Clause 2.2, steps, retaining walls, objects or level changes
that would otherwise reduce the height of a barrier within a property shall not be located
within 500 mm of the barrier (see Figure 2.1(a)).
2.3.2 Perforated material or mesh
Barriers using perforated and mesh materials shall comply with the following:
(a)

Barriers within the property using materials with apertures not greater than 13 mm
shall have a height not less than 1200 mm and comply with the relevant provisions of
Clauses 2.1 and 2.2.

(b)

Barriers using material with apertures greater than 13 mm but not greater than
100 mm shall have a height of not less than 1800 mm.

(c)

Material with apertures greater than 100 mm shall not be used.

(d)

Apertures shall be measured horizontally across their widest part.

(e)

Barriers within the property shall be installed in such a manner and with sufficient
height so that

(f)

(i)

when a 25 kg weight is supported at any point along on the top of the barrier, it
shall not reduce the barrier height to less than 1200 mm; and

(ii)

when a vertical lift force of 100 N is applied at any point along the bottom of
the barrier, it shall not result in a gap between the bottom of the barrier and the
surface beneath, of more than 100 mm.

Perforated materials or mesh shall be durable and shall comply with the requirements
of Clause 3.3.2.

Standards Australia

www.standards.org.au

13

AS 1926.12012

2.3.3 Glass barriers

Glass gates using top and bottom pivot style hinges shall comply with dimensions of
Figure 2.4.

100 max.
50 min.

Glass panel
G l a s s g ate

FG L

120 0 m i n.

Glass panel

9 0 0 m i n.

Pivot h i n g e

1 0 0 0 m i n.

Licensed to Mr Ken Bridges on 23 April 2014. 1 user personal license only. Copying, copy/pasting, storage & distribution or use on network prohibited. (10459277).
Get permission to copy from or network this publication www.saiglobal.com/licensing

Glass used in barriers shall comply with the provisions of AS 1288.

10 0 m a x.

Pivot h i n g e
DIMENSIONS IN MILLIMETRES

FIGURE 2.4 GLASS GATE WITH PIVOT HINGES

2.3.4 Surface projections and indentations


Projections and indentations, or any combination thereof, within the NCZ 1, shall not form
a horizontal surface with a depth greater than 10 mm (see Figure 2.5).
For a barrier having random projections and/or indentations with horizontal surfaces of a
depth greater than 10 mm the following requirements shall apply:
(a)

All such lower surfaces shall be not less than 900 mm from the top of the barrier.

(b)

All such higher surfaces shall be not less than 900 mm above the finished ground
level.

(c)

High and low surfaces shall be not less than 900 mm apart.

The relevant surface for projections shall be the top horizontal surface and for indentations
shall be the bottom horizontal surface.
NOTE: On such barriers the location of NCZ 1 may vary along the length of a barrier (see
Figure 2.5).

www.standards.org.au

Standards Australia

AS 1926.12012

14
Pr oj e c ti o n

To p of b a r r i e r
Indentation

Licensed to Mr Ken Bridges on 23 April 2014. 1 user personal license only. Copying, copy/pasting, storage & distribution or use on network prohibited. (10459277).
Get permission to copy from or network this publication www.saiglobal.com/licensing

900
N CZ 1

900
N CZ 1

900
900
N CZ 1

900

900

900

900

900
N CZ 1

120 0 m i n

900
N CZ 1

900
N CZ 1

FG L
3D VIEW

DIMENSIONS IN MILLIMETRES

FIGURE 2.5 BARRIERS WITH PROJECTIONS AND INDENTATIONS


GREATER THAN 10 mm

2.3.5 Horizontal components


In addition to the relevant requirements of Clause 2.2, barriers less than 1800 mm in height
shall comply with the following:
(a)

No barrier shall incorporate a horizontal component within NCZs 1 and 2, with a top
surface depth greater than 10 mm nor any component, that can be used as a handhold
or foothold, unless such top surface is sloped at not less than 60 from the horizontal
plane (see Figure 2.6).

(b)

Where a barrier is sloping, NCZs shall be parallel to the top of the barrier (see
Figure 2.8(a)).

(c)

Where a barrier is stepped at a ground level change or installed with steps on a gentle
slope the integrity of all applicable NCZs shall be maintained (see Figure 2.8 (b)
and (c)).

(d)

Rails or other components or items on the inside of barriers shall not constitute holds
for climbing where the opening between vertical components is not greater than
10 mm (see Figure 2.7).

2.3.6 Vertical components


The clear opening between any vertical components shall not exceed 100 mm at any point
in a barrier (see Figures 2.7 and 2.8).
2.3.7 Ground clearance
The height of any opening between the bottom of the barrier and the finished ground level
shall not exceed 100 mm.
The surface beneath the barrier shall be permanent and not easily removed or eroded by a
young child, animals or weather.

Standards Australia

www.standards.org.au

15

AS 1926.12012

10 0 m a x.

Licensed to Mr Ken Bridges on 23 April 2014. 1 user personal license only. Copying, copy/pasting, storage & distribution or use on network prohibited. (10459277).
Get permission to copy from or network this publication www.saiglobal.com/licensing

900

N CZ 2
120 0
m i n.

N CZ 4

N CZ 1

N CZ 1
9 0 0 m i n.

S e e D e t a il A

60
m i n.

C h a mfe r

FG L

(a ) O U T S I D E E LE VAT I O N

S EC T I O N

900
D E TA I L A
N CZ 2
S e e D e t a il A

N CZ 1
9 0 0 m i n.

120 0
m i n.

N CZ 4

N CZ 1

FG L

( b) O U T S I D E E LE VAT I O N

S EC T I O N

DIMENSIONS IN MILLIMETRES

FIGURE 2.6 HORIZONTAL COMPONENTS NOT ACTING AS A HOLD FOR CLIMBING

To p of b a r r i e r

To p of b a r r i e r

To p of b a r r i e r

9 0 0 ( N CZ 1)

120 0
m i n.

FG L
(a) Ve r ti c a l o p e ni n g s n ot
m o r e t h a n 10 m m w i t h
h o r izo nt a l c o m p o n e nt s
l e s s th a n 9 0 0 m m a p a r t
o n i n s i d e b a r r i e r.

( b) Ve r ti c a l c o m p o n e nt s
s p a c e d n ot m o r e t h a n
10 0 m m a p a r t

(c) B a r r i e r wi th s eve r a l
h o r izo nt a l c o m p o n e nt s , s u c h
a s we l d e d s te e l c o n s t r u c ti o n

DIMENSIONS IN MILLIMETRES

FIGURE 2.7 HORIZONTAL COMPONENTS


www.standards.org.au

Standards Australia

AS 1926.12012

16

Licensed to Mr Ken Bridges on 23 April 2014. 1 user personal license only. Copying, copy/pasting, storage & distribution or use on network prohibited. (10459277).
Get permission to copy from or network this publication www.saiglobal.com/licensing

10 0 m a x.

9 0 0 m i n.

Ve r ti c a l
c o m p o n e nt

120 0 m i n.

FG L
9 0 0 ( N CZ 1)

120 0 m i n.

10 0 m a x.

10 0 m a x.

(a) S l o p i n g g r o u n d

10 0 m a x.

Ve r ti c a l s te p i n
b a r r i e r to b e s a m e
a s ve r ti c a l s te p 'D'

Ve r ti c a l
c o m p o n e nt
120 0 m i n.
9 0 0 ( N CZ 1)

9 0 0 ( N CZ 1)

FG L

9 0 0 ( N CZ 1)

120 0 m i n.

Ve r ti c a l
s te p 'D'

10 0 m a x.
10 0 m a x.
( b) S te p p e d g r o u n d

DIMENSIONS IN MILLIMETRES

FIGURE 2.8 (in part) PERPENDICULAR BARRIER DIMENSIONS

Standards Australia

www.standards.org.au

17

AS 1926.12012

Licensed to Mr Ken Bridges on 23 April 2014. 1 user personal license only. Copying, copy/pasting, storage & distribution or use on network prohibited. (10459277).
Get permission to copy from or network this publication www.saiglobal.com/licensing

10 0 m a x.

900
( N CZ 1)

120 0
m i n.

Ve r ti c a l
C o m p o n e nt

FG L
FG L
10 0 m a x.

(c) S li g htl y s l o p i n g g r o u n d
DIMENSIONS IN MILLIMETRES

FIGURE 2.8 (in part) PERPENDICULAR BARRIER DIMENSIONS

2.4 GATES, GATE UNITS AND LATCH FITTINGS


2.4.1 Gates
2.4.1.1 Operation of gates
Gates shall be hung so that they only swing outwards, i.e. away from the pool area.
Gates shall be located so that the arc of operation is clear of any building or doorway.
Gates shall have sufficient clearance to swing freely through the arc of operation.
The opening under a closed gate shall not exceed 100 mm at any point.
2.4.1.2 Self-closing device
Gates shall be fitted with a self-closing device that will close the gate from any position,
with a stationary start, without the application of a manual force and operate the latch.
The self-closing device shall be capable of complying with these requirements with the gate
at any position from fully open to resting on the latch.
NOTES:
1 The self-closing device may require a cushioned back-checking operation to prevent shock
when the gate is closing.
2 Gates subject to wind loading (which may prevent their closing) may require special
consideration.

2.4.1.3 Security of closure


Gates shall be hung so that when a gate is closed and latched, and is lifted upwards or
pulled downwards with a force of 250 N, movement of the gate does not
(a)

release the latch;

(b)

unhinge the gate; or

(c)

increase the opening between the bottom of the gate and the finished ground level to
more than 100 mm.

www.standards.org.au

Standards Australia

AS 1926.12012

18

2.4.2 Latch

Licensed to Mr Ken Bridges on 23 April 2014. 1 user personal license only. Copying, copy/pasting, storage & distribution or use on network prohibited. (10459277).
Get permission to copy from or network this publication www.saiglobal.com/licensing

2.4.2.1 General
Gates shall be fitted with a latch that will automatically operate on the closing of the gate
and will prevent the gate from being re-opened without being manually released. The latch
shall not be able to be
(a)

inadvertently adjusted during operation;

(b)

locked in the open position; or

(c)

adjusted without the use of tools.

A latch shall not be able to be released by the insertion of any implement in the 10 mm
opening shown in Figure 2.9.
2.4.2.2 Location of the latch (see Figure 2.9)
Where the release point of the latch is located at a height less than 1500 mm above the
finished ground level, the location of the latch shall
(a)

not be on the outside of the barrier;

(b)

be in such a position that to release the latch from the outside it will be necessary to
reach over or through the barrier at a height of not less than 1200 mm above the
finished ground level or not less than 1000 mm above the highest lower horizontal
member; and

(c)

be at least 150 mm below the top of the barrier if a hand-hole is not provided, or at
least 150 mm below the edge of any hand-hole if provided.

2.4.2.3 Shielding of latch (see Figure 2.9)


In a gate with vertical openings greater than 10 mm, where the latch release is located at a
height less than 1500 mm above the finished ground level, the latch release shall be
shielded so that no opening greater than 10 mm occurs within an area bounded by
(a)

an effective radius of 450 mm from the latch release; and

(b)

the top of the barrier, if this intersects the area described in Item (a).

Where it is necessary to have a hand-hole in a gate, the bottom of the opening shall be not
less than 1200 mm above the finished ground level, and the shielding shall be extended up
to a horizontal line through the top of the hand-hole, or 150 mm above the top of the latch
release, whichever is the higher.
The shield shall be free of sharp edges and the edges of the adjacent parts of the shield on
the gate and the barrier shall be rounded or chamfered to prevent a hazard when the gate
closes.
2.4.3 Gate hinges
Gate hinges that protrude out from the barrier with a horizontal top surface depth greater
than 10 mm and those that create an opening between the gate post and the gate stile of
more than 10 mm shall not be permitted in NCZs 1 and 2.
Hinges with a top surface sloped at 60 to the horizontal or more may be located within
NCZs 1 and 2.
2.4.4 Gate units
2.4.4.1 General
This Clause (2.4.4) sets out requirements for manufacturers for the design, construction,
performance and sale of gate units to be installed as part of a barrier.

Standards Australia

www.standards.org.au

19

AS 1926.12012

2.4.4.2 Supply of gate units

Licensed to Mr Ken Bridges on 23 April 2014. 1 user personal license only. Copying, copy/pasting, storage & distribution or use on network prohibited. (10459277).
Get permission to copy from or network this publication www.saiglobal.com/licensing

Gate units shall be supplied as complete sets of components with all parts necessary for
correct installation.
NOTE: Gate units may be supplied fully assembled or with some assembly required.

Gate units shall be of a permanent nature.


Gate units shall be supplied with a set of written instructions as follows:
(a)

Installation instructions which include all necessary information including foundation


requirements to allow erection of the gate unit as part of a barrier complying with this
Standard.

(b)

Parts list and exploded diagram showing all of the components supplied.

(c)

Maintenance instructions including any special requirements for maintaining the


latching mechanism and hinges.

(d)

A statement explaining the need to keep the automatic closing device properly
adjusted.

(e)

A statement that the gate is required to swing outwards, away from the pool area.

2.4.4.3 Types of materials


Gate units may be constructed from any type of material, provided that the finished
components comply with the requirements of this Standard.
NOTE: Components of gate units should be effectively protected against corrosion, UV
degradation and other effects of exposure to weather, sunlight, pool chemicals and water.

2.4.4.4 Marking of gate units


Each gate unit shall be clearly and permanently marked on at least one of the gate posts or
on the gate or on some other component of the gate unit with the registered trademark or the
name and address of the manufacturer.
The following methods of marking are acceptable:
(a)

Self-adhesive metalized label which cannot be removed without the use of a tool such
as a scraper.

(b)

Metal plate secured by rivets.

(c)

Stamping or moulding of the information into a component.

NOTE: Manufacturers making a statement of compliance with this Australian Standard on a


product, packaging, or promotional material related to that product are advised to ensure that such
compliance is capable of being verified.

2.4.4.5 Testing
Test requirements for gate units are set out in Clauses 3.5 and 3.6.

www.standards.org.au

Standards Australia

AS 1926.12012

20

O p e ni n g
10 m a x.

Licensed to Mr Ken Bridges on 23 April 2014. 1 user personal license only. Copying, copy/pasting, storage & distribution or use on network prohibited. (10459277).
Get permission to copy from or network this publication www.saiglobal.com/licensing

4 50 m i n.

Barrier

150 m i n.

4 50 m i n.

120 0
m i n.

G ate

Barrier

10 0 m a x.

G a p 10 0 m a x.

( b) L atc h m o r e th a n 150 b e l ow to p of b a r r i e r
(s hi e l di n g i s c e ntr e d o n l atc h)

(a) B a s i c r e q u i r e m e n t s

O p e ni n g
10 m a x.
4 50 m i n.

B ot to m of
h a n d h o l e n ot
c l o s e r to
l a tc h th a n
150

150 m i n.

S hi e l di n g
r a di u s
4 50 m i n.
f r o m l atc h
c e ntr e
Barrier

G ate

O p e ni n g
10 m a x.

Barrier

B ot to m of
hand hole
n ot l e s s
t h a n 120 0
a b ove FG L
a n d n ot
i n N CZ .

G ate

G ate
10 0 m a x.

10 0 m a x. b e t we e n
ve r ti c a l c o m p o n e nt s
(c) S hi e l d l a r g e r th a n m i ni m u m s ize

(d ) H a n d h o l e p r ovi d e d i n b a r r i e r

L atc h
release

L atc h
release

Barrier

Pi c ke t s p a c i n g
(s e e Cl a u s e 2. 3.6)

FG L

G ate

150 0
m i n.

Barrier

G ate

150 0
m i n.

(e) S hi e l d n ot r e q u i r e d fo r l atc h o r r e l e a s e
l o c ate d n ot l e s s th a n 150 0 a b ove FG L

DIMENSIONS IN MILLIMETRES

FIGURE 2.9 ALTERNATIVE LATCH SHIELDING OPTIONS FOR GATES WITH


VERTICAL OPENINGS 10100 mm

Standards Australia

www.standards.org.au

21

AS 1926.12012

2.5 OTHER BARRIERS

Licensed to Mr Ken Bridges on 23 April 2014. 1 user personal license only. Copying, copy/pasting, storage & distribution or use on network prohibited. (10459277).
Get permission to copy from or network this publication www.saiglobal.com/licensing

2.5.1 Retaining wall above the pool level


A retaining wall (or similar feature) that acts as a barrier above the pool level shall comply
with the following:
(a)

It shall not slope away from the pool by more than 15 (see Figure 2.10 (a)(i) and
(b)(i)).

(b)

When less than 1800 mm in height, it shall comply with Clauses 2.1, 2.2.1, 2.2.2,
2.3.4 and 2.3.5(a) (see Figure 2.10 (b)(i) and (c)(i)).

2.5.2 Retaining wall below the pool level


A retaining wall (or similar feature) that acts as a barrier below the pool level shall comply
with the following:
(a)

It shall not slope towards the pool by more than 15 (see Figure 2.10 (a)(ii) and
(b)(ii)).

(b)

When less than 1800 mm in height, it shall comply with Clauses 2.1, 2.2.1, 2.2.2,
2.3.4 and 2.3.5(a) (see Figure 2.10 (b)(ii) and (c)(ii).

Where a barrier intersects a retaining wall that is below the pool level, as shown in
Figure 2.10(d), that barrier shall extend to the outer edge of the retaining wall and either
overhang the retaining wall by 900 mm (shown as option C), or return 900 mm along the
retaining wall in either direction (shown as options A and B).
Barriers using option A or B shall be affixed, as close as practicable, to the outside face of
the retaining wall.

www.standards.org.au

Standards Australia

AS 1926.12012

22

INSIDE
15 m a x.
18 0 0 m i n.
Licensed to Mr Ken Bridges on 23 April 2014. 1 user personal license only. Copying, copy/pasting, storage & distribution or use on network prohibited. (10459277).
Get permission to copy from or network this publication www.saiglobal.com/licensing

(m ay b e c l i m b a b l e)

OUTSIDE
Po o l

Po o l

(m ay b e c l i m b a b l e)
18 0 0 m i n.
15 m a x.

( i ) A b ove th e p o o l

( ii ) B e l ow th e p o o l

(a) R e t a i ni n g wa ll 18 0 0 m m m i n. h e i g ht

N CZ
1& 2

120 0 m i n.

INSIDE

FG L
15 m a x.

OUTSIDE

Po o l

15 m a x.
N CZ
120 0 to 18 0 0
1& 2
FG L

Po o l

( i ) A b ove th e p o o l

( ii ) B e l ow th e p o o l

( b) R e t a i ni n g wa ll 120 0 to 18 0 0 m m h e i g ht

N CZ
1& 2

120 0 m i n.
FG L

N CZ
1& 2
120 0 m i n.
FG L
Po o l

( i ) A b ove th e p o o l

Po o l
( ii ) B e l ow th e p o o l

(c) R e t a i ni n g wa ll l e s s th a n 120 0 m m h e i g ht
DIMENSIONS IN MILLIMETRES

FIGURE 2.10 (in part) RETAINING WALL OR OTHER SUCH BARRIER

Standards Australia

www.standards.org.au

Licensed to Mr Ken Bridges on 23 April 2014. 1 user personal license only. Copying, copy/pasting, storage & distribution or use on network prohibited. (10459277).
Get permission to copy from or network this publication www.saiglobal.com/licensing

23

AS 1926.12012

Complying
r e t a i ni n g wa ll
Po o l

9 0 0 r e tu r n
(o pti o n A )
Po o l b a r r i e r

9 0 0 r e tu r n
(o pti o n B)

9 0 0 ove r h a n g (o pti o n C)

(d ) Po o l b a r r i e r i nte r s e c ti n g r e t a i ni n g
wa ll s o n l owe r s i d e of p o o l

DIMENSIONS IN MILLIMETRES

FIGURE 2.10 (in part) RETAINING WALL OR OTHER SUCH BARRIER

2.5.3 Out-of-ground pool walls


Out-of-ground walls of pools that comply with the requirements of a barrier in this Standard
shall be considered an effective barrier. (For above-ground pools, see Clause 2.9.)
2.5.4 Permanent bodies of water
Permanent bodies of water of a width greater than 1800 mm shall be considered as an
effective barrier where a pool owner is able to provide evidence showing that the body of
water is permanent and the water at the edge of the pool area is not less than 300 mm deep
at any time.
NOTE: Refer to relevant authorities for the minimum water depths of a waterway.

2.6 CHILD-RESISTANT OPENABLE PORTION OF WINDOW


Where a window opens directly into the pool area and the height from the sill of the lowest
opening panel of the window to the finished ground level in the pool area is less than
1800 mm, the openable portion of the window shall comply with one of the following:
(a)

Be totally covered by bars or a metal screen, that are fixed to the building with
fasteners that can only be removed by the use of a tool. The opening between bars and
the horizontal dimension of openings in a metal screen shall not be greater than
100 mm.

(b)

Be fixed to the building with fasteners that can only be removed by the use of a tool
so that it will remain closed or will open to a maximum of 100 mm.

www.standards.org.au

Standards Australia

AS 1926.12012

24

2.7 CHILD RESISTANT DOORSETS

Licensed to Mr Ken Bridges on 23 April 2014. 1 user personal license only. Copying, copy/pasting, storage & distribution or use on network prohibited. (10459277).
Get permission to copy from or network this publication www.saiglobal.com/licensing

Child-resistant doorsets shall only be installed for access to indoor pools and the indoor part
of an indoor/outdoor pool and shall comply with the following:
(a)

Doors shall be fitted with a self-closing device that will close the door from any
position, with a stationary start, without the application of a manual force and operate
the latch.

(b)

The self-closing device shall be capable of complying with these requirements with
the door at any position fully open to resting on the latch.

(c)

Doors shall be fitted with a latch that complies with Clause 2.4.2 and which will
automatically operate on the closing of the door and prevent the door from being reopened without being manually released.

(d)

The release for the latch shall be located on the outside of the door and not less than
1500 mm above the floor.

(e)

NCZ 1 shall apply to the outside of a door and the top of NCZ 1 shall be 1200 mm or
less above the floor. See Clause 2.2.2(a).

(f)

Perforated materials or mesh shall comply with the requirements of Clause 2.3.2.

(g)

Pet doors shall not be placed in a child-resistant doorset.

(h)

Door shall not open towards the pool.

NOTE: For examples of locations for use of doorsets see AS 1926.2.

Standards Australia

www.standards.org.au

25

AS 1926.12012

Licensed to Mr Ken Bridges on 23 April 2014. 1 user personal license only. Copying, copy/pasting, storage & distribution or use on network prohibited. (10459277).
Get permission to copy from or network this publication www.saiglobal.com/licensing

2.8 BALCONY BALUSTRADES


A balcony that protrudes into an NCZ shall be fitted with a balustrade that complies with
Clauses 2.1, 2.2.1 and 2.2.2. See Figure 2.11.

Balustrade that
c o m p li e s wi th
this Standard

B a l c o ny

W i n d ow s
and doors
to b a l c o ny

900
N CZ 3
900
N CZ 2
120 0 min .
Barrier

FG L

Po o l

DIMENSIONS IN MILLIMETRES

FIGURE 2.11 BALCONY INTRUDING INTO NCZ

2.9 ABOVE-GROUND POOLS


For above-ground pools that are factory fabricated and designed for assembly and
installation on site, including inflatable pools, the walls of the pool shall be considered an
effective barrier provided they comply with the relevant provisions of Clauses 2.1 to 2.3.
A barrier complying with Clauses 2.1 to 2.4 shall be placed around permanently fixed
access ladders and around a designated access point to above-ground pools with removable
ladders.
NOTE: Above-ground pools pose a particular hazard because of the tendency to leave climbable
objects against or near the pool, which may be used for access into the pool.

www.standards.org.au

Standards Australia

AS 1926.12012

26

Licensed to Mr Ken Bridges on 23 April 2014. 1 user personal license only. Copying, copy/pasting, storage & distribution or use on network prohibited. (10459277).
Get permission to copy from or network this publication www.saiglobal.com/licensing

S E C T I O N

L O A D I N G

R E Q U I R E M E N T S

3.1 STRENGTH AND RIGIDITY OF OPENINGS


A barrier with vertical openings wider than 10 mm shall have vertical components with
sufficient strength and rigidity such that a 105 +0, 0.5 mm diameter metal cone cannot
pass through the opening under the application of a force of 150 N.
When tested in accordance with Appendix A the test object shall not pass through the
openings.
3.2 STRENGTH OF POSTS AND FOOTINGS
Each post and footing shall withstand a horizontal force of 330 N at 1200 mm above
finished ground level. After loading, there shall be no permanent damage to any post, the
footings shall not loosen to impair the effectiveness of the barrier.
NOTES:
1 A method that may be used to test posts and footings is provided in Appendix B.
2 330 N is approximately 33 kg. This test can be conducted in the field by fastening one end of
a calibrated force measuring device to the post 1200 mm above ground level and pulling on
the other end of the balance until a load of 33 kg is achieved. After application of the load,
inspect the post and footing for any looseness or damage.

3.3 STRENGTH OF BARRIER COMPONENTS


3.3.1 Rigid components
Structural components, such as panel infills, top and bottom rails, rods, palings, pickets,
and the like, shall be capable of sustaining a force of 330 N without any component
(a)

breaking;

(b)

showing signs of fracture;

(c)

loosening so the effectiveness of the panel is impaired; or

(d)

becoming permanently deformed by more than a factor of 1/200 over its length.

Testing of barrier panels shall be in accordance with Appendix C.


3.3.2 Flexible material and components
Flexible barrier components and materials, and the manner in which they are installed, shall
be capable of withstanding the dynamic forces imparted with no permanent deformation
when tested in accordance with Appendix D.
3.4 CLOSING AND LATCHING OF GATES
In addition to the requirements of Clauses 2.4.1 to 2.4.3 each gate shall comply with the
following:
(a)

The gate shall close and latch from fully open to resting on the latch, under both of
the following conditions:
(i)

Under the natural weight of the gate.

(ii)

With the gate open and after a weight of 25 kg has been placed on the top rail
or component at a point 100 mm from the outer edge of the locking stile of the
gate for 30 seconds and then removed.

NOTE: This requirement is intended to indicate whether the automatic closing and latching
mechanism is likely to remain effective after the gate has been subject to deflection, either
under its own weight or as a result of children swinging on it.
Standards Australia

www.standards.org.au

27

Licensed to Mr Ken Bridges on 23 April 2014. 1 user personal license only. Copying, copy/pasting, storage & distribution or use on network prohibited. (10459277).
Get permission to copy from or network this publication www.saiglobal.com/licensing

(b)

AS 1926.12012

With the gate closed, the latch and posts of the barrier to which the gate is attached
shall be capable of retaining the gate in a closed position when the weight in
Item (a)(ii) is placed at the same location and remains on the gate.

3.5 STRENGTH AND RIGIDITY OF A GATE UNIT


When tested in accordance with Appendix E, no component of gate units shall fracture,
break or loosen so the effectiveness of the gate unit is impaired or permanently deformed by
a factor of more than 1/200 over its length. The latch shall not unintentionally release and
the gate shall still comply with Clause 2.4 at the end of the test.
3.6 DURABILITY OF A GATE UNIT
When a gate unit is tested in accordance with Appendix F, it shall
(a)

be capable of complying with the requirements of Clauses 2.4.1 to 2.4.3 after 10 000
operations; and

(b)

the force required to release the latch shall not be greater than 50 N both before and
after the test.

www.standards.org.au

Standards Australia

AS 1926.12012

28

Licensed to Mr Ken Bridges on 23 April 2014. 1 user personal license only. Copying, copy/pasting, storage & distribution or use on network prohibited. (10459277).
Get permission to copy from or network this publication www.saiglobal.com/licensing

APPENDIX A

TEST FOR STRENGTH AND RIGIDITY OF BARRIER OPENINGS


(Normative)
A1 SCOPE
This Appendix sets out a method for determining whether a barrier is sufficiently strong
and rigid to prevent an opening from being forced to a size that would allow a young child
to gain entry. This Appendix is to be used by manufacturers to gain certification for their
barrier. It is not designed for in-field testing.
WARNING: THIS TEST SHALL NOT BE USED ON A GLASS BARRIER.

A2 PRINCIPLE
A horizontal force is applied to the test object in an attempt to force it through the openings
in the barrier panel.
A3 APPARATUS
The following apparatus is required:
(a)

A cylindrical solid-faced test object 105 +0, 0.5 mm in diameter with a body length
of 300400 mm, as shown in Figure A1.
One end shall be conical and shall be truncated to a nominal diameter of 20 mm to
provide a flat base for the attachment of fittings, as shown in Figure A1.
The test object shall be mild steel and have a smooth machined finish.

(b)

A calibrated force-measuring device with an accuracy of 2% of the test loads and a


resolution of 1 N or less.

(c)

A stable supporting structure to suspend the conical test object from and to hold the
barrier panel in a vertical position, as shown in Figure A1.

(d)

A means of attaching the force-measuring device to the conical test object, as shown
in Figure A1.

(e)

A force activating device.

A4 PROCEDURE
The procedure shall be as follows:
(a)

Secure the panel into the supporting structure (jig) in the vertical position.

(b)

Hang the test object from the supporting structure. The test object shall be suspended
horizontally at two points by using a suspension method that minimizes the effects of
friction and allows free movement, as shown in Figure A1.

(c)

Attach the force measuring device to the conical end of the test object, as shown in
Figure A1. Connect the other end of the force measuring device to the force
activating device.

(d)

Each panel shall be tested in three locations, across the width of the panel at the
middle of each third of the panel.

(e)

Place the conical end of the test object into the opening being tested and steadily
apply a force up to 150 N, in an attempt to force the object through the opening.
Should the test object oscillate during the test it shall be stabilized.

Standards Australia

www.standards.org.au

29

(f)

AS 1926.12012

Record the force at which the test object pulled through the panel or that it failed to
pull through the panel.

Licensed to Mr Ken Bridges on 23 April 2014. 1 user personal license only. Copying, copy/pasting, storage & distribution or use on network prohibited. (10459277).
Get permission to copy from or network this publication www.saiglobal.com/licensing

A5 REPORT
The report shall include the information shown in Figure A2 and clearly show the
following:
(a)

The pull-through force at which the conical test object passed through the panel
openings or that it failed to pass through the panel when tested in the three locations
specified in Paragraph A4(d).

(b)

Reference to this test method, i.e. AS 1926.1, Appendix A.

(c)

The conclusion of whether the panel has passed or failed the test in accordance with
the criteria in Clause 3.1.

www.standards.org.au

Standards Australia

AS 1926.12012

30

Fr e e h a n g i n g sys te m

Fe n c e p a n e l

Fo r c e
ac tivatin g
d ev i c e

Te s t c o r e

S E E D E TA I L A

Fo r c e
m e a s u r e m e nt
d ev i c e

NOT E:
X = L/2 whe r e L i s t he d i st a nc e b et we e n t he lowe r
t op a nd t he h ig he r b ot t om hor i z ont a l me mb e r s.

Hanging poin
ntt s

300 - 400

+ 0
0.5

10 5 -

20 n o m.

+ 0
- 0.5

At t a c h fo r c e
m e a s u r e d evi c e

10 5

Licensed to Mr Ken Bridges on 23 April 2014. 1 user personal license only. Copying, copy/pasting, storage & distribution or use on network prohibited. (10459277).
Get permission to copy from or network this publication www.saiglobal.com/licensing

S u p p o r ti n g ji g

D E TA I L A

DIMENSIONS IN MILLIMETRES

FIGURE A1 APPARATUS FOR TESTING OPENINGS AND OTHER COMPONENTS

Standards Australia

www.standards.org.au

Licensed to Mr Ken Bridges on 23 April 2014. 1 user personal license only. Copying, copy/pasting, storage & distribution or use on network prohibited. (10459277).
Get permission to copy from or network this publication www.saiglobal.com/licensing

31

AS 1926.12012

Date:

.......................................

Test Report No.:

.......................................

Product:

Name of product

Material

Specify product material

Source

Name of manufacturer/supplier/consumer

Specifications:

AS 1926.1, Swimming pool safetyPart 1: Safety barriers for swimming pools,


Appendix A, Test for strength and rigidity of barrier openings

Wire-based panel
Panel dimensions:
Item No.

Product

Product name

Wire size (mm)

Horizontal wire
spacings (mm)

Upright wire ResultsPullopenings


through force
CC (mm)
(N)

Tubular panel
Panel dimensions:
Item No.

Product

Product name

Tube size (mm)

Horizontal rail
spacings (mm)

Upright tube ResultsPullopenings


through force
CC (mm)
(N)

Conclusion and comments: ..............................................................................................................


..............................................................................................................
Name of individual conducting the test: ............................................................................................
Individuals title:

............................................................................................

Authorized signatory:

............................................................................................

Name and location of testing ......................................................................................................


facility:
......................................................................................................

FIGURE A2 EXAMPLE TEST REPORTBARRIER PANEL

www.standards.org.au

Standards Australia

AS 1926.12012

32

Licensed to Mr Ken Bridges on 23 April 2014. 1 user personal license only. Copying, copy/pasting, storage & distribution or use on network prohibited. (10459277).
Get permission to copy from or network this publication www.saiglobal.com/licensing

APPENDIX B

STRENGTH TEST FOR POSTS AND FOOTINGS


(Informative)
B1 SCOPE
This Appendix sets out a method for testing whether barrier posts have adequate strength
and have been correctly installed.
WARNING: THIS TEST IS NOT TO BE APPLIED TO A GLASS BARRIER.

B2 PRINCIPLE
A force is applied to the barrier post and it is then inspected for signs of fracture, loosening
of footings or any damage or deformation of the post or if to a gate post any damage or
deformation that would prevent the gate from closing and latching from any position.
B3 APPARATUS
The following apparatus is required:
(a)

A cylindrical test object of diameter 105 1 mm, having at least one solid flat-faced
end.

(b)

A calibrated force-measuring device with an accuracy of 2% of the test load and a


resolution of 1 N or less.

(c)

A means of applying and measuring the applied force being applied.

Te s t fa c e

FIGURE B1 TEST OBJECT

B4 PROCEDURE
The procedure is as follows:
(a)

Place the flat end of the test object against the post under test at a height of 1.2 m
above finished ground level at 90 to the barrier.

(b)

Apply a horizontal force of 330 N, without shock, to the test component.

(c)

Apply the test force for a minimum of 30 seconds.

(d)

Remove the force and inspect the post for damage or loosening of the footings.

(e)

For gate posts, the test is to be carried out with the gate held or chocked in a partly
open position. After testing check that the gate will close and latch when released
from various positions from a 90 opening to resting on the latch.

Standards Australia

www.standards.org.au

33

AS 1926.12012

B5 REPORT

Licensed to Mr Ken Bridges on 23 April 2014. 1 user personal license only. Copying, copy/pasting, storage & distribution or use on network prohibited. (10459277).
Get permission to copy from or network this publication www.saiglobal.com/licensing

The report is to include the following information:


(a)

Breakage or sign of fracture of any post.

(b)

Loosening of any part of the barrier that will impair its effectiveness.

(c)

Any damage to the gate that would prevent it from closing and latching from any
position.

(d)

Whether the post or gate passed or failed the test.

(e)

Reference to this test method, i.e. AS 1926.1, Appendix B.

www.standards.org.au

Standards Australia

AS 1926.12012

34

Licensed to Mr Ken Bridges on 23 April 2014. 1 user personal license only. Copying, copy/pasting, storage & distribution or use on network prohibited. (10459277).
Get permission to copy from or network this publication www.saiglobal.com/licensing

APPENDIX C

STRENGTH TEST FOR RIGID BARRIER COMPONENTS


(Normative)
C1 SCOPE
This Appendix sets out a method for testing whether barrier components have adequate
strength.
WARNING: THIS TEST SHALL NOT BE APPLIED TO A GLASS BARRIER.

C2

PRINCIPLE

A force is applied to the component or components of the barrier and it is then inspected for
signs of fracture, permanent deformation or loosening of components.
Measurements shall be accurate to 0.5 mm.
C3 APPARATUS
The following apparatus is required:
(a)

A cylindrical test object of diameter 105 1 mm, having at least one solid flat-faced
end (see Figure C1).

(b)

A calibrated force-measuring device with an accuracy of 2% of the test load and a


resolution of 1 N or less.

(c)

A means of applying the force.

Te s t fa c e

FIGURE C1 TEST OBJECT

C4

PROCEDURE

The procedure shall be as follows:


(a)

Connect the force measuring device to test object.

(b)

Place the flat end of the test object against the test component at its most flexible
point.

(c)

Using the force measuring device, apply a pre-load force of 50 N for a minimum of
30 seconds. Remove the force and measure the zero load displacement.

(d)

Using the force measuring device apply a force of 330 N, without shock, for a
minimum of 30 seconds.

(e)

Remove the test force and measure and record the amount of permanent deformation
of the component relative to the zero load displacement.

Standards Australia

www.standards.org.au

35

Licensed to Mr Ken Bridges on 23 April 2014. 1 user personal license only. Copying, copy/pasting, storage & distribution or use on network prohibited. (10459277).
Get permission to copy from or network this publication www.saiglobal.com/licensing

(f)

AS 1926.12012

Inspect the component for


(i)

breakage or sign of fracture of any component; and

(ii)

loosening of any component that will impair the effectiveness of the panel.

C5 REPORT
The report shall include the following information:
(a)

The amount of permanent deformation recorded in C4(e).

(b)

Whether the barrier panel conforms to the requirements of Clause 3.3.2 after testing.

(c)

Reference to this test method, i.e. AS 1926.1, Appendix C.

www.standards.org.au

Standards Australia

AS 1926.12012

36

Licensed to Mr Ken Bridges on 23 April 2014. 1 user personal license only. Copying, copy/pasting, storage & distribution or use on network prohibited. (10459277).
Get permission to copy from or network this publication www.saiglobal.com/licensing

APPENDIX D

STRENGTH TEST FOR FLEXIBLE MATERIALS AND COMPONENTS


(Normative)
D1 SCOPE
The Appendix sets out a method for testing whether flexible materials and components have
adequate strength and whether such materials are adequately fixed to ensure they comprise
a suitable barrier.
D2 PRINCIPLE
A dynamic force is applied to the material or component and it is then inspected for signs of
penetration, breakage, tearing or signs of fracture or loosening of components.
D3 APPARATUS
The following apparatus is required:
(a)

Test object a 9.1 kg half spherical solid-faced test object 50 1 mm diameter.

(b)

A means of swinging the test object through an arc of radius 1400 mm.

D4 PROCEDURE
The procedure shall be as follows:
(a)

Suspend test object A at the distance of 1400 mm below a pivot point to allow a
pendulum action and place the test object against the material or component.

(b)

Raise the test object to a 40 angle to the vertical (see Figure D1) and release.

(c)

The test shall be carried out from both sides of the component and at the weakest
points.

(d)

Inspect for the following:


(i)

Breakage, tearing or signs of fracture.

(ii)

Loosening of any component or fixings.

D5 REPORT
The report shall include the following:
(c)

Whether there was


(i)

breakage, tearing or signs of fracture of any material and component; or

(ii)

loosening of any components or fixings that impaired the effectiveness of the


barrier.

(d)

Whether the material and component passed or failed the test.

(e)

Reference to this test method, i.e. AS 1926.1, Appendix D.

Standards Australia

www.standards.org.au

Licensed to Mr Ken Bridges on 23 April 2014. 1 user personal license only. Copying, copy/pasting, storage & distribution or use on network prohibited. (10459277).
Get permission to copy from or network this publication www.saiglobal.com/licensing

37

40

www.standards.org.au

AS 1926.12012

14 0 0 m m

C o m p o n e nt

Te s t o bj e c t

FIGURE D1 TEST OBJECT

Standards Australia

AS 1926.12012

38

Licensed to Mr Ken Bridges on 23 April 2014. 1 user personal license only. Copying, copy/pasting, storage & distribution or use on network prohibited. (10459277).
Get permission to copy from or network this publication www.saiglobal.com/licensing

APPENDIX E

STRENGTH TEST FOR RIGID COMPONENTS OF GATE UNITS


(Normative)
E1 SCOPE
This Appendix sets out a method for testing whether the strength of structural components
of gate units are sufficiently robust to provide an effective barrier throughout the life of the
barriers. This test is only for use by manufacturers of gate units.
WARNING: THIS TEST SHALL NOT BE APPLIED TO A GLASS GATE UNIT.

E2 PRINCIPLE
A force is applied at a number of locations on the gate unit and it is then inspected for signs
of fracture, permanent deformation and any faulty operation of the latching device.
E3 APPARATUS
The following apparatus is required:
(a)

A cylindrical test object of diameter 105 1 mm, having at least one solid flat-faced
end (see Figure B1).

(b)

A calibrated force-measuring device with an accuracy of 2% of the test load and a


resolution of 1 N or less.

(c)

A means of applying the force.

E4 PROCEDURE
The procedure shall be as follows:
(a)

Close and latch the gate.

(b)

Using the test object, apply a force of 330 N in a horizontal direction to the centre of
the gate panel.

(c)

Using the test object, apply a force of 330 N in a horizontal direction to each of the
four corners of the gate.

(d)

Repeat Steps (b) and (c) from the other side of the gate unit.

(e)

Using the test object, apply a force of 330 N in a horizontal direction to any part of
the gate at, or below, 1200 mm above finished ground level, which is a point of
potential weakness.

(f)

Inspect the gate unit for any breakage, fracture or permanent deformation.

(g)

Record whether the latch was released during the test.

(h)

Open the gate and hold it in a position so that it is just ajar with the components of
the latch on the gate post and the latching stile disengaged and clear of each other.

(i)

Using the test object, apply a force of 250 N in a vertical direction to the top rail of
the gate at a point 100 mm from the outer edge of the latching stile. Where the design
of the gate precludes access to the top rail at that point, the force may be applied
closer to the latching stile of the gate.

(j)

Remove the test force and check that the gate automatically closes and the latch
operates.

Standards Australia

www.standards.org.au

Licensed to Mr Ken Bridges on 23 April 2014. 1 user personal license only. Copying, copy/pasting, storage & distribution or use on network prohibited. (10459277).
Get permission to copy from or network this publication www.saiglobal.com/licensing

39

(k)

Inspect the gate unit for any breakage, fracture or permanent deformation.

(l)

All required forces shall be applied and held for 30 seconds.

AS 1926.12012

E5 REPORT
The report shall include the following information:
(a)

Whether there was any breakage or fracture of any part.

(b)

The distance that any part deformed, in millimetres.

(c)

Whether the latch was unintentionally released during the tests.

(d)

Whether the gate still complied with Clause 2.4 at the end of the test.

(e)

Reference to this test method, i.e. AS 1926.1, Appendix E.

www.standards.org.au

Standards Australia

AS 1926.12012

40

Licensed to Mr Ken Bridges on 23 April 2014. 1 user personal license only. Copying, copy/pasting, storage & distribution or use on network prohibited. (10459277).
Get permission to copy from or network this publication www.saiglobal.com/licensing

APPENDIX F

TEST OF DURABILITY OF GATE UNITS


(Normative)
F1 SCOPE
This Appendix sets out a method of assessing the ability of a gate, including its hinges and
latch, to withstand repeated closing. This test is only for use by manufacturers of gate units.
F2 PRINCIPLE
The gate unit is subject to a number of repeated opening and closings, and then inspected
for compliance with the design requirements.
F3 APPARATUS
The following apparatus is required:
(a)

A means of releasing the latch and opening the gate to the 90-degree position.

(b)

A means of measuring the force applied to release the latch.

F4 PROCEDURE
The procedure shall be as follows:
(a)

Install the gate unit in accordance with the manufacturers instructions on a site
which simulates the in situ condition with the gate posts securely anchored into the
ground.

(b)

Ensure that the gate and its latch comply with Clause 2.4.

(c)

Measure and record the force (to the nearest 5 N) required to release the latch.

(d)

Release the latch and open the gate to the 90-degree position.

(e)

Release the gate and allow it to close under the action of the self-closing device.

(f)

Repeat Steps (d) and (e) for a total of 10 000 operations or until the latch fails to
operate, whichever occurs first. The latch shall not be lubricated or adjusted during
this test.

(g)

Inspect the gate to see whether it still complies with Clause 2.4.

(h)

Measure and record the force (to the nearest 5 N) required to release the latch.

(i)

Inspect the gate, including the hinges and latch together with the gate posts, for any
damage which would affect the ability of the gate to comply with the requirements of
Section 2.

F5 REPORT
The report shall include the following information:
(a)

The number of operations of the gate that were completed.

(b)

Whether the gate still complied with Clause 2.4 at the end of the test.

(c)

The force required to release the latch at the start and at the end of the test.

(d)

Any damage to the gate, hinges, latching device or gate posts at end of the test.

(e)

The number of this test method, i.e. AS 1926.1, Appendix F.

Standards Australia

www.standards.org.au

Licensed to Mr Ken Bridges on 23 April 2014. 1 user personal license only. Copying, copy/pasting, storage & distribution or use on network prohibited. (10459277).
Get permission to copy from or network this publication www.saiglobal.com/licensing

41

AS
1926
1926.2

www.standards.org.au

AS 1926.12012

BIBLIOGRAPHY

Swimming pool safety


Part 2: Location of safety barriers for swimming pools

Standards Australia

Licensed to Mr Ken Bridges on 23 April 2014. 1 user personal license only. Copying, copy/pasting, storage & distribution or use on network prohibited. (10459277).
Get permission to copy from or network this publication www.saiglobal.com/licensing

AS 1926.12012
42

NOTES

Licensed to Mr Ken Bridges on 23 April 2014. 1 user personal license only. Copying, copy/pasting, storage & distribution or use on network prohibited. (10459277).
Get permission to copy from or network this publication www.saiglobal.com/licensing

43

NOTES

AS 1926.12012

Licensed to Mr Ken Bridges on 23 April 2014. 1 user personal license only. Copying, copy/pasting, storage & distribution or use on network prohibited. (10459277).
Get permission to copy from or network this publication www.saiglobal.com/licensing

AS 1926.12012
44

NOTES

Licensed to Mr Ken Bridges on 23 April 2014. 1 user personal license only. Copying, copy/pasting, storage & distribution or use on network prohibited. (10459277).
Get permission to copy from or network this publication www.saiglobal.com/licensing

Standards Australia
Standards Australia develops Australian Standards and other documents of public benefit and national interest.
These Standards are developed through an open process of consultation and consensus, in which all interested
parties are invited to participate. Through a Memorandum of Understanding with the Commonwealth Government,
Standards Australia is recognized as Australias peak non-government national standards body. Standards Australia
also supports excellence in design and innovation through the Australian Design Awards.
For further information visit www.standards.org.au

Australian Standards
Committees of experts from industry, governments, consumers and other relevant sectors prepare Australian
Standards. The requirements or recommendations contained in published Standards are a consensus of the views
of representative interests and also take account of comments received from other sources. They reflect the latest
scientific and industry experience. Australian Standards are kept under continuous review after publication and are
updated regularly to take account of changing technology.

International Involvement
Standards Australia is responsible for ensuring the Australian viewpoint is considered in the formulation of
International Standards and that the latest international experience is incorporated in national Standards. This role is
vital in assisting local industry to compete in international markets. Standards Australia represents Australia at both
the International Organization for Standardization (ISO) and the International Electrotechnical Commission (IEC).

Sales and Distribution


Australian Standards, Handbooks and other documents developed by Standards Australia are printed and
distributed under license by SAI Global Limited.

Licensed to Mr Ken Bridges on 23 April 2014. 1 user personal license only. Copying, copy/pasting, storage & distribution or use on network prohibited. (10459277).
Get permission to copy from or network this publication www.saiglobal.com/licensing

For information regarding the development of Standards contact:


Standards Australia Limited
GPO Box 476
Sydney NSW 2001
Phone: 02 9237 6000
Fax: 02 9237 6010
Email: mail@standards.org.au
Internet: www.standards.org.au
For information regarding the sale and distribution of Standards contact:
SAI Global Limited
Phone: 13 12 42
Fax: 1300 65 49 49
Email: sales@saiglobal.com

ISBN 978 1 74342 253 3

Das könnte Ihnen auch gefallen