Sie sind auf Seite 1von 74

BSC architecture and

functions
BSS S13

Soc Classification level


1
Nokia Siemens Networks

RN28126EN13GLN0

BSC architecture and functions

After this module you will be able to:


Explain the BSC architecture
Explain the BSC computer units and their
function
Explain the main functions of the BSC

Soc Classification level


2
Nokia Siemens Networks

RN28126EN13GLN0

S13 SW
Nokia BSC S13 software consists of Operating Software
and Application Software
Operating Software: Includes the basic functionalities and
enhancements
Application Software: Consists of value-adding
functionalities
S13 release supported
Nokia BSC product
variants:
BSC3i

BSCE
TCSME

BSC2i

BSC2E

BSCi

BSC2A

TCSM3i
TCSM2
Soc Classification level
3
Nokia Siemens Networks

S13 release non-supported


Nokia BSC product variants:

RN28126EN13GLN0

Block diagram of BSC3i 660

Switching
Platform

Computing
platform

Soc Classification level


4
Nokia Siemens Networks

RN28126EN13GLN0

BSC3i 1000/2000 Architecture (S12)


BTS

MSC
SET

Ater

Gb over
Frame Relay

SET

TCSM3i

SGSN
CLS

SET

GSW2KB

BTS
ET

ET

Ater

Gb over
Frame Relay

MSC

TCSM2i or
TCSM3i

SGSN
CLS

ET

Gb over IP

SGSN

PCU

SGSN

BCSU

Internal
LAN
Switch
PIU for
PCU LAN

MCMU

OMU

MO
Hard Disk Drive
Drive

EMB

Internal LAN Switch PIU for PCU LAN

Connector Panel
(EMC and NE interaface)

Soc Classification level


5
Nokia Siemens Networks

RN28126EN13GLN0

Rack layout of DX200 BSC2i


BSC2i
CC19
V

BCB

BCE

PSA20_0
PSFP0

PSA20_1
PSFP1

GSWB CLS
CLOC
1
O1
1SW1C1 3
9
7
CBD
8
MCMU 0
MCMU 1
MC1C
MC1C
GSWB 0
SW1C0

01

27

OMU
MC1C

SD3C-S
O1

27

ET5CET5C
1
0
0
1

13

BCSU 1
MC1C

O1

Soc Classification level


6
Nokia Siemens Networks

BCSU 0
MC1C

PSA20_2
PSA20_3
PSFP2
PSFP3
CLS ET5CET5CET5C
3
4
CLAC 2

R2A1-S
152

120

O1

BCSU 3
MC1C

O1

BCSU 5
MC1C

O
1

BCSU 7
MC1C

O1

BCSU 4
MC1C

27

BCS
U6
27
MC1
C
BCSU 8
MC1C
27

088

058

030

27

BCSU 2
MC1C

27

RN28126EN13GLN0

ET5CET5CET5CET5C
5
6
7
8
0
1

13

002

Rack layout of BSC3i 660


CPRJ45

CPGO

PDFU 3

PDFU-A

PDFU-A

PDFU-A

PDFU-A

GSWB 0

GSWB 1

SW1C-C

SW1C-C

CLOC-B

PDFU 2

CLS 0,1

PDFU 1

MCMU 0 MCMU 1
CC4C-A

CC4C-A

FTRB 0

BCSU 6
CC3C-A

OMU
CM2C-A

FTRB 1

BCSU 0

BCSU 1

BCSU 2

CC3C-A

CC3C-A

CC3C-A

BCSU 3

BCSU 4

BCSU 5

CC3C-A

CC3C-A

CC3C-A

FTRB 2

Soc Classification level


7
Nokia Siemens Networks

CPGO

PDFU 0

RN28126EN13GLN0

FTRB 3

ET4C 0

ET4C 1

ET4C-B
(32*ET2E/A)

ET4C-B
(30*ET2E/A)

BSC3i 1000 & 2000 Cabinet Configuration


BSC3i base cabinet

Extension cabinet
PDFU 1
CLAC

PDFU 0

ET ET

Fan tray

ET

Fan tray

ET

BCSU BCSU BCSU

BCSU

BCSU BCSU BCSU

BCSU BCSU

Fan tray
CLAC

LANU

LANU

Fan tray

Fan tray

(300)

RN28126EN13GLN0

M98F2

Cabinet mechanics

PDFU
Fuses

Power Distribution &

GSW2KB

Bit Group Switch

MCMU

Marker and Cellular


Management Unit

BCSU

BCSU
Fan
tray

ET or ET or
ETS ETS

2000 x 900 x 600


Soc Classification level
8
Nokia Siemens Networks

ET

Fan tray
LANU

ET

OMU

LANU

GSW2KB
MCMU

Fan tray

CLOC

GSW2KB

PDFU 1

MCMU

PDFU 0

Cabling option

2000 x 900 x 600

BCSU
including

BSC Signaling Unit


Packet Control Units

OMU
Operation &
Maintenance Unit
including
System Disk and
MagnetoOptical Drive
LANU
LAN

LAN cartridge including


Switching Units (SWUs)

CLOC
Clock &
Synchronization Unit
CLAC

Clock Repeater

ETS
Terminal

SHD/Sonet Exchange

BSC3i 1000/2000 - Cartridges


BSCD

BSCC-C

CC4C-A

CC4C-A

CM2C-A

FTRB 1(FTRB-A)

BCSU 0

BCSU 1

BCSU 2

CC3C-A

CC3C-A

CC3C-A

BCSU 3

BCSU 4

BCSU 5

CC3C-A

CC3C-A

CC3C-A

FTRB 3(FTRB-A)
CLAC-B

CLAC 0

LANU 1

LASWC-A

LANU 0

LASWC-A

FTRB 2(FTRB-A)

GTIC 0

GTIC 1

GT4C-A

GT4C-A

RN28126EN13GLN0

CLAC 1

ETC 4

ETC 5

ETC 6

ETC 7

GT4C-A

GT4C-A

GT4C-A

GT4C-A

FTRB 0(FTRB-A)
BCSU 6
CC3C-A

FTRB 1(FTRB-A)
LANU 3

OMU

LASWC-A

MCMU 1

PDFU-B

LANU 2

ETC 1

ETC 0

MCMU 0

FTRB 0(FTRB-A)

Soc Classification level


9
Nokia Siemens Networks

GT6C-A

CLOC

CLOC-B

SW10C-A

PDFU 1

PDFU-APDFU-B

PDFU-B

GSW2KB 0GSW2KB 1
SW10C-A

PDFU 0

PDFU 1

LASWC-A

PDFU-APDFU 0
PDFU-B

CPETS-E

CLAC-B

CPGO

CPRJ45-A

CPETS-E

GT6C-A

CPETS-E

BCSU 8

BCSU 9

CC3C-A

CC3C-A

FTRB 2(FTRB-A)

BCSU 7
CC3C-A

BCSU 10
CC3C-A

FTRB 3(FTRB-A)

Group Switch GSWB ( BSC2i)

Soc Classification level


10
Nokia Siemens Networks

RN28126EN13GLN0

SW64B

SW64B

SW64B

SW64B

PSC1

SWBU
S4

MBIF
MBIF

SWCO
P
PSC3

Marker and Cellular Management Unit, MCMU (


BSC2i )

2 3
10
Soc Classification level
11
Nokia Siemens Networks

RN28126EN13GLN0

Soc Classification level


12
Nokia Siemens Networks

MBIF

AS7

AS7

AS7

2 3

RN28126EN13GLN0

PCU/-S

PSC3

MBIF

CPU

PCU/-S

Base Station Controller Signalling Unit, BCSU


( BSC2i)

9 10

Soc Classification level


13
Nokia Siemens Networks

RN28126EN13GLN0

SCSI
F

HWA
TPSC3

AS7-U

AS7-U/AC25/COCEN

AS7-U/AC25/COCEN
2 3
10

MBIF

MBIF

CPU

Operation & Maintenance Unit, OMU ( BSC2i)

MCMU for BSC3i 660

DBG
ETH1

ETH1

ETH2

ETH2

RST

J7

CPU

J6

OPR

OPR

OPR

OPR

OPR

MBIF-B 1

RST

MBIF-B 0

RST

RUN
LF

SWCOP-A

PSC6-A

ESB20

ESB20

WO

OL
TE
AP
DRAM
SB
CPSI

ON

SCSI
J5

J5

ETx0

OFF

ERx0
ETx1
ERx1

Soc Classification level


14
Nokia Siemens Networks

RN28126EN13GLN0

OPR

RUN0

RUN0

RUN1

RUN1

DBG

MBIF-B 1

OPR

RST

J7

J6

OPR

CPU

MBIF-B 0

PCU-B 5, 6

PCU-B 3, 4

AS7-B 2

AS7-B 1

PSC6-A

AS7-B 0

BCSU for BSC3i 660

WO
RUN
LF
OL

AP

AP

TE

AP

AP
DRAM
SB
CPSI
SCSI
ETx0
ERx0

ON
OFF

ETx1
ERx1

Soc Classification level


15
Nokia Siemens Networks

RN28126EN13GLN0

10

MBIF-B 1
OPR

RST

AP

AP

TE

SW0

AP

WO
RUN
LF
OL

AP
DRAM
SB

SW1

HDPU-A + WDW18-S

J6

HDPU-A + WDW18-S

J7

ODPU-A + M091

OPR

RST

CPU

HWAT-A

MBIF-B 0

DBG

SERO-A

AS7-B 2 / AC25-A

OPR

AS7-B 1 / AC25-A

PSC6-A

AS7-B 0

OMU for BSC3i 660

13

14

CPSI
SCSI
ETx0
ERx0
ETx1
ERx1

ON
OFF

Soc Classification level


16
Nokia Siemens Networks

RN28126EN13GLN0

10

12

BSC3i 1000 & 2000 Introduction


BSC3i 1000 & BSC3i 2000
Very high circuit and packet handling capacity from up to 2000
TRXs
Compact size compared to capacity
Built-in SDH/SONET connectivity for easy commissioning to support
fast roll-out
Nokia BSC3i variants:
S11.5:
BSC3i 660
S13: BSC3i 660/1000/2000
Existing BSC3i 660 can be upgraded to 1000 or 2000.
This requires major HW upgrade.
No other BSCs can be upgraded to 1000 or 2000 TRX
Soc Classification level
17
Nokia Siemens Networks

RN28126EN13GLN0

BSC Configurations (S13)

BSCi

BSC2i

BSC3i 660

BSC3i 1000

BSC3i 2000

Maximum Radio network configuration

248 BCF
512 BTS
512 TRX

248 BCF
512 BTS
512 TRX

248/504 BCF
660 BTS
660 TRX

1000 BCF
1000 BTS
1000 TRX

2000 BCF
2000 BTS
2000 TRX

Allowed CPU Type in OMU

CP6LX
CP6MX

CP6LX
CP6MX

CP710

CP816

CP816

Allowed CPU Type in MCMU

CP6LX
CP6MX

CP6LX
CP6MX

CP710

CP816

CP816

Allowed CPU Type in BCSU

CP6LX
CP6MX

CP6LX
CP6MX

CP710

CP81

CP816

Allowed Group Switch type / Maximum


number of internal PCMs

GSWB/12
8
GSWB/19
2

GSWB/128
GSWB/192
GSWB/256

GSWB/256
(S10.5/S10.5ED/S11)
GSW1KB/512 (S11.5/S13)

GSW2KB/2048

GSW2KB/2048

Number of AS7-U cards in BCSUs

0-1

Number of AS7-V cards in BCSUs

2-3

Number of AS7-B cards in BCSUs

Number of AS7-C cards in BCSUs

Maximum Number of external PCMs

56/88

80/112/144

124 / 256
(ET2s) (ET4s)

384

800

Maximum Number of STM-1 / OC-3 interfaces

16

16

Type of LapD and Q1 terminal in OMU

AS7-V

AS7-V / -VA / X

AS7-B (S10.5/S10.5ED)
AS7-C (S11/S11.5)

AS7-C

AS7-C

Minimum number of WO-EX BCSUs

1-8

1-8

1-6

1-5

1-10

Number of BCFSIG LapD links per BCSU

32

32

84

200

200

Number of TRXSIG LapD links per BCSU

64

64

110

200

200

Maximum number of LapD links per BCSU


(BCFSIG + TRXSIG + ISDN+ET-LAPD)

117

124

170 (AS7-B)
206 (AS7-C)

448

448

Maximum number of SDCCHs per BCSU

768

768

1760

3200

3200

Maximum number of TCHs per BCSU

512

512

880

1600

1600

Soc Classification level


18
Nokia Siemens Networks

RN28126EN13GLN0

BSC3i 1000/2000 TRXs

1200

400

600

800

1000

1200

1800

Max. 2000

BTS

200

400

600

800

1000

1200

1800

2000

BCF

200

400

600

800

1000

1200

1800

2000

BCSUs (1 redundant included)

10

11

Logical PCUs:
With PCU step 1
With max PCUs

2
10

4
20

6
30

8
40

10
50

12
60

18
90

20
100

Max. # of 16 kbit/s Abis channels for (E)GPRS use

2560

5120

7620

10240

12800

15360

23040

25600

Max. radio TSL

1600

3200

4800

6400

8000

9600

14400

16000

8
4
2
2
1

16
8
4
4
2

16
12
6
6
3

16
16
8
8
4

16
16
10
10
5

16
16
12
12
6

16
16
16
16
9

16
16
16
16
10

Max. # of LAPD links (BCFSIG + TRXSIG +ISDN+ET/SET)

448

896

1344

1792

2240

2688

4032

4480

Example 1 max PCMs


E1 / T1
STM-1 / OC-3

384
none

384
none

384
none

384
none

384
none

800
8

800
8

800
8

Example 2
E1 / T1
STM-1 / OC-3

128
6

128
12

128
16

128
16

128
16

288
16

288
16

288
16

Max.# of SS7 links


64kbit/s
128kbit/s
256kbit/s
512kbit/s
2Mbit/s

Soc Classification level


19
Nokia Siemens Networks

RN28126EN13GLN0

BSC3i 1000/2000 HW changes


New Units:
New FTRB-A enhanced fan units
CP816-A CPU for all computer units
Bit based group switch for 2048 PCMs (GSW2KB)
ET16 for E1/T1 interface
ETS2 for STM-1 or OC-3 interface
CLAB for clock repeating
ESB26 Ethernet Switch
Architecture changes
Ethernet Message Bus (EMB)
LANU
10 + 1 BCSU units (5+1 in basic cabinet)
Removed units:
MBIFs
Soc Classification level
20
Nokia Siemens Networks

RN28126EN13GLN0

BSC3i 1000/2000 Cartridges in 1st Cabinet


(Computer Units)
BSC3i base cabinet

MCMU

OMU

MCMU
MCMU OMU

BCSU BCSU BCSU

BCSU

BCSU BCSU BCSU

900 x 600 x 2000


Soc Classification level
21
Nokia Siemens Networks

RN28126EN13GLN0

BSC3i 1000/2000 Cartridges in 1st Cabinet (Other


Units)
BSC3i base cabinet

GSW2KB

ETC
ETC

CLOC

CLAC

Soc Classification level


22
Nokia Siemens Networks

RN28126EN13GLN0

GTIC

GTIC

GTIC

LANU
LANU
CLAC

LANU

GSW2KB

GSW2KB

CLOC

ETC

BSC3i 1000/2000 Functional Units in 2nd Cabinet


Extension cabinet

CLAC

CLAC

ETC

BCSU

BCSU

LANU
LANU

ETC ETC ETC ETC

BCSU

BCSU BCSU BCSU

Soc Classification level


23
Nokia Siemens Networks

RN28126EN13GLN0

LANU

M98F2 cabinet mechanics

Air Guide
Cartridge shelf maximum
allowed power 300 W
Plug-in unit slot 25 W
CPU slot 50 W

Cartridge shelf maximum


allowed power 650 W
Plug-in unit slot 25 W
CPU slot 50 W

IC209-A with FTRB-A


Cabinet level maximum power 3,0 kW
FTRB-A

FTRB-A
30% of
maximum
allowed
shelf
power

Cartridge shelf maximum


allowed power 650 W
Plug-in unit slot 25 W
CPU slot 50 W

Cartridge shelf maximum


allowed power 800 W
Plug-in unit slot 35 W
CPU slot 70 W
FTRB-A

FTRB-A

Cartridge shelf maximum


allowed power 800 W
Plug-in unit slot 35 W
CPU slot 70 W

Soc Classification level


24
Nokia Siemens Networks

RN28126EN13GLN0

FTRB-A (enhanced fan tray unit)


front plate of plug-in unit

BOTTOM

FTRB-A

TOP

New part air flow also in front


of plug-in unit front plates.

Soc Classification level


25
Nokia Siemens Networks

RN28126EN13GLN0

BSC3i Processing Unit


CP816-A, Pentium III Central Processing Unit
Mobile PentiumIII with approx. 1.6 GHz frequency
512 MB SDRAM
Provides standard V.24/V.28 based Service
Terminal interfaces in front panel
The unit is connected to the back plane via
Compact PCI bus, SCSI and Ethernet based
Message bus
one CPCI 33Mhz, 32 bits
two Wide Ultra3 SCSI
four 10/100/1000 Mbit/s Ethernet ports
For all computer units in BSC3i 1000/2000:
OMU, MCMU and BCSU

Soc Classification level


26
Nokia Siemens Networks

RN28126EN13GLN0

GSW2KB
2048 real PCMs
16384 virtual PCMs
Switching on 8kbit/s level
Max. 65536 8kbit/s channels for one
SW256B
8 x SW256B Units
8Mbit/s serial connections towards
ET16
via back panel
2 HotLinks / SW256 towards ETS2
via front panel
Soc Classification level
27
Nokia Siemens Networks

RN28126EN13GLN0

ET16 E1/T1 Interface

GT6C-A (ETC 0 & 1)

Full height ET interface


plug-in unit
E1/T1 interfaces in steps of
16, max 800 E1/T1s
Only one variant of ET16
that fulfills E1, T1
requirements

Soc Classification level


28
Nokia Siemens Networks

RN28126EN13GLN0

GT4C-A (ETC 27, GTIC 0 & 1)

ETS2 SDH/SONET Interface


ETS2 provides an optical STM-1 or
OC-3 interface to SDH network
STM-1 = 63 x E1 PCM (ETSI)
OC-3 = 84 x T1 PCM (ANSI)
STM-1/OC-3 optical interfaces with
bit rate of 155,52 Mbit/s *
2 separate interfaces per unit
+ Optical interface redundancy
Up to 16 ETS2 units in BSC3i
1000/2000
Max. 16 STM-1/OC-3 interfaces
Connected to GSW2KB via Hotlink
Soc Classification level
29
Nokia Siemens Networks

RN28126EN13GLN0

2 Alternatives of ETS2:

Soc Classification level


30
Nokia Siemens Networks

RN28126EN13GLN0

Example cabling of ETS2


A. Hotlink cablings from GT4C-A slots 1...4

B. STM-1/OC-3 cablings from GT4C-A slots 1...4

ETS2 plug-in units in slots 1...4

ETS2 plug-in units in slots 1...4

SB 1 - 0

SB 1 - 0

SB 1 - 0

SB 1 - 0

SB 1 - 0

SB 1 - 0

SB 1 - 0

SB 1 - 0

SB 1 - 1

SB 1 - 1

SB 1 - 1

SB 1 - 1

SB 1 - 1

SB 1 - 1

SB 1 - 1

SB 1 - 1

SB 2 - 0

SB 2 - 0

SB 2 - 0

SB 2 - 0

SB 2 - 0

SB 2 - 0

SB 2 - 0

SB 2 - 0

SB 2 - 1

SB 2 - 1

SB 2 - 1

SB 2 - 1

SB 2 - 1

SB 2 - 1

SB 2 - 1

SB 2 - 1

OPR

Tx/Rx
Fail

Tx/Rx
Fail

Tx/Rx
Fail

STM-1/OC-3

STM-1/OC-3

STM-1/OC-3

STM-1/OC-3

STM-1/OC-3

STM-1/OC-3

STM-1/OC-3

TX

TX

TX

TX

TX

TX

TX

TX

0
M

0
M

0
M

0
M

0
M

0
M

0
M

0
M

RX

RX

RX

RX

RX

RX

RX

RX

STM-1/OC-3

STM-1/OC-3

STM-1/OC-3

STM-1/OC-3

TX

TX

TX

TX

0
R

0
R

0
R

0
R

0
R

RX

RX

RX

RX

RX

RX

RX

RX

STM-1/OC-3

STM-1/OC-3

STM-1/OC-3

TX

TX

TX

1
M

1
M

1
M

1
M

RX

RX

RX

RX

SHIM4T

STM-1/OC-3
TX

SHIM4T

STM-1/OC-3
TX

0
R

SHIM4T

STM-1/OC-3
TX

0
R

SHIM4T

STM-1/OC-3
TX

0
R

SHIM4T

STM-1/OC-3
TX

STM-1/OC-3

STM-1/OC-3

STM-1/OC-3

STM-1/OC-3

TX

TX

TX

TX

1
M

1
M

1
M

1
M

RX

RX

RX

RX

STM-1/OC-3

STM-1/OC-3

STM-1/OC-3

STM-1/OC-3

STM-1/OC-3

STM-1/OC-3

STM-1/OC-3

STM-1/OC-3

TX

TX

TX

TX

TX

TX

TX

TX

1
R

1
R

1
R

1
R

1
R

1
R

1
R

1
R

RX

RX

RX

RX

RX

RX

RX

RX

Front side

Hotlink cables from


STM-1/OC-3 interfaces
to GSW2KB 0
Note 1! If ET16 pius are equipped
to GT4C-A cartridges (GTIC 0 & 1)
instead of Hotlink cables, these
Hotlink cables are fastened somewhere
for not causing any harm
Note 2! In production these
Hotlink cables can not be
connected on the PIU end, so
they are fastened somewhere
for not causing any harm and
they will not get damaged

Soc Classification level


31
Nokia Siemens Networks

OPR

RN28126EN13GLN0

SHIM4T

OPR

Tx/Rx
Fail

SHIM4T

OPR

Tx/Rx
Fail

SHIM4T

OPR

Tx/Rx
Fail

SHIM4T

OPR

Tx/Rx
Fail

SHIM4T

OPR

Tx/Rx
Fail
STM-1/OC-3

Hotlink cables from


STM-1/OC-3 interfaces
to GSW2KB 1

OPR

Front side
STM-1/OC-3 cables from
STM-1/OC-3 interfaces
to customer network via
CPGO panel. These cables
are not included in the
BSCC-C cabinet type

Use of PCM circuits in GSW2KB


ANSI environment

ETSI environment
GSW2KB

GSW2K
B

All ET index in range


between 0 2047
(ET16, ET4 & STM-1)
2047
2048
3391
3392

PCM 2048 3391 not


used

Virtual PCMs in range


3392 - 22463

19775
19776
22463
Soc Classification level
32
Nokia Siemens Networks

PCMs 19776 22463 not


used
RN28126EN13GLN0

ET16 ET index in
range 0 - 2047

1
204
7
204
8
339
1
339
2

19775
19776
22463

Correspond GSW PCM


some where between 0 - 2048

Second Generation Packet Control Unit PCU2-D


Two PCU functions are integrated in one
plug-in unit; 2 microprocessor blocks are
identical and work independently to
handle the tasks
Includes Power PCs assembled to the
same plug in-unit with 2 x 256 MB
SDRAM memory
Includes also DSPs with 16 MB memory
Supports standard external interfaces
two 10 Base-T /100 Base-TX Ethernet
Supports high speed internal interfaces

Soc Classification level


33
Nokia Siemens Networks

RN28126EN13GLN0

two 8 Mbit/s PCM line to GSW2KB

BSC3i Hard Disks

Standard Hardware Unit in


BSC3i
Duplicated Hard disk units per
BSC to ensure high reliability
Easy to change or upgrade
without traffic interruption

Soc Classification level


34
Nokia Siemens Networks

RN28126EN13GLN0

BSC3i Magneto Optical (MO) Unit

Standard Hardware Unit in BSC3i


Optical disk will provide reliable
means for backup copying SW
and database on a transferable
media in BSC
Provides even better reliability and
performance with longer media life
cycle compared with Digital Audio
Tape (DAT) technology.
New BSC3i deliveries are
configured with 9.1G MO units

Soc Classification level


35
Nokia Siemens Networks

RN28126EN13GLN0

BSC3i clock unit

Clock and Tone


Generator
(CL3TG) plug-in units
Allows external
synchronization input
via connector panel
Housed in the CLOCB cartridge

2 x CL3TG units
(2N redundancy)
Soc Classification level
36
Nokia Siemens Networks

RN28126EN13GLN0

BSC3i clock repeater

Clock and Alarm Buffer


(CLAB-S) plug-in units
Housed in the CLAC-B
cartridge

2 x CLAB-S units
in base cabinet
2 x CLAB-S units
in extension
cabinet
(2N redundancy)
Soc Classification level
37
Nokia Siemens Networks

RN28126EN13GLN0

CLAB-S overview
CLAB-S offers the following cartridge-specific services to the
functional units and PIUs of the exchange.
Collection of wired alarms
CLAB-S collects the wired alarms from the cartridges and
conveys them in message format to the maintenance
computer via supervision bus . All CLAB-S PIU in the
exchange are connected to the same supervision bus.
Distribution of basic timing signals
CLAB-S receives the timing signals ( 16MHZ and 8KHZ )from
synchronization unit over the basic timing bus and uses them
to generate the basic timing signals to be distributed to the
cartridges ( 8 MHZ and 8KHZ )
Distribution of switch changeover signal
CLAB-S receives the switch changeover signal and buffers it
before it is distributed to the cartridges.
Soc Classification level
38
Nokia Siemens Networks

RN28126EN13GLN0

10 + 1 BCSU units
5 PSU plug-in units per
BCSU
1-2 PCU-Bs
1-5 PCU2-Ds

Soc Classification level


39
Nokia Siemens Networks

0 1

9 10

Plug-in units in BCSU


PSC6-A power supply
1-2 x PCU-B or1-5 x PCU2D
2 x AS7-C
CP816-A
RN28126EN13GLN0

S11.5 and S13 comparison:

Soc Classification level


40
Nokia Siemens Networks

RN28126EN13GLN0

BSC3i 1000/2000 Plug in Units


Used also in
Nokia BSC3i 660

Used also in
Nokia Core MSS, HLR, etc.

AS7-C
CL3TG
ESB26
HDPU-A
HWAT-A
MO91
ODPU-A
PCU2-D
PSC6-A
SERO-B
SWCOP-A
WDW73

CLAB-S
CP816-A

Soc Classification level


41
Nokia Siemens Networks

New units in BSC3i 1000/2000


SW256B
ET16
ETS2

RN28126EN13GLN0

LANU
2N redundant LANU unit
in basic cabinet
Contains 3 ESB26
units
2N redundant LANU unit
in extensin cabinet
Only if more than 6
working BCSUs in use
Extension to LANU in
basic cabinet
Contains 1 ESB26 unit

Soc Classification level


42
Nokia Siemens Networks

RN28126EN13GLN0

LANU External Connections


Both 1000Base-Sx LAN interfaces (ports 0407, 1215) for
1 Gbit/s uplinks and 10/100/1000Base-T/Tx LAN interfaces
(ports 0003, 0811) for 10/100 Mbit/s & 1 Gbit/s copper
uplinks in CPRJ45-A panel will be used in S13 new delivery
BSC3i. Uplinks can be chosen from 3 uplink alternatives:
10 Mbit/s uplink (copper)
100 Mbit/s uplink (copper)
1 Gbit/s uplink (both copper
and optical available).
LAN INTERFACES
01

02

03

Tx

08

09

10

11

Rx

12

Tx

LPT 0

VDU 0

16

17

(V.24)

(V.24)

VDU 1

VDU 2

24

25

(V.24)

(V.24)

SYMM 0

SYMM 1

CLS 0, 1

CLS 0, 1

18

VDU 2

05

Tx

06

Rx

13

Rx

20
ASYMM 0

Tx

Tx

07

Rx

14

Rx

21

Tx

Tx

Rx

15

Rx

Tx

22

IEC/EN 60825 - 1

00

1000Base-Sx uplinks

04

CLASS 1 LASER PRODUCT

10/100/1000Base-T/Tx uplinks

Rx

23

CLS 0, 1

19

LPT 2

28
ASYMM 1
CLS 0, 1

26
(V.11)

27
(V.11)
CURRENTCONTROLLED

EXT SYNC IN EXT AL INPUT EXT AL OUTPUTAL INPUTS

LPT/VDU INTERFACES
B

Soc Classification level


43
Nokia Siemens Networks

RN28126EN13GLN0

INTERFACES
A

EXT AL INTERFACES

BSC3i LANU connection principle 1:

Soc Classification level


44
Nokia Siemens Networks

RN28126EN13GLN0

BSC3i LANU connection principle 2:

Soc Classification level


45
Nokia Siemens Networks

RN28126EN13GLN0

BSC3i 1000/2000 CPU LAN & PCU LAN

Soc Classification level


46
Nokia Siemens Networks

RN28126EN13GLN0

BSC 3i 1000/2000 CPU LAN & EMB

Soc Classification level


47
Nokia Siemens Networks

RN28126EN13GLN0

BSC 3i 1000/2000 PCU LAN

Soc Classification level


48
Nokia Siemens Networks

RN28126EN13GLN0

Reference: BSC3i 660 LAN Connection Principle


EXAMPLE CONFIGURATION:
IP
Network

BSC3i
cabinet
BCSU
0
CPU

BCSU
6
CPU

MCMU
0
CPU

MCMU
1
CPU

OMU
CPU

2x100 Mbps uplink

MCMU IP switch
0
IP switch

VRRP

2x100
Mbps
2x100
Mbps

MCMU IP switch
1
IP switch

2x100 Mbps uplink

PCU

EMC
Interface
(Connector
panel)
Soc Classification level
49
Nokia Siemens Networks

RN28126EN13GLN0

PCU

BCS
U0

PCU

PCU

BCS
U6

Ethernet based Message Bus (EMB)


EMB, 0
MCMU,0

ESB26

CP816-A with 4 LAN ports

BCSU 0

BCSU 1

BCSU 10

MCMU 0

MCMU 1

OMU

- 2 used for redundant


EMB

ESB26

MCMU,1

Switched LAN is used


EMB, 1
LAN is 2N redundant
EMB LANs are physically separate from the internal LAN
cabling & LAN-switches used by the internal LAN have been excluded from the
picture

Each computer reads its EMB address from EMB address plug
EMB address has same value as MB address
Soc Classification level
50
Nokia Siemens Networks

RN28126EN13GLN0

EMB Addressing
ADMODxx, Address Module connector
ADMODxx is going to be connected into rear of CP816-A PIU to
make Ethernet MB address.
There are total of 32 different ADMOD address module
connectors available: ADMOD00 ADMOD31.
ADMODxx has 2x5 size 2mm Z-pack HM cable connector.
A
A

Soc Classification level


51
Nokia Siemens Networks

RN28126EN13GLN0

Switched LAN vs. MB

EMB,0
ESB14-A

ESB26

CCSU,0

CCSU,1

CCSU,2

OMU,
0

OMU,
1

CCSU,0

CCSU,1

ESB26

CCSU,2

OMU,
0

OMU,
1

MB,0
MB,1
ESB26

ESB26

ESB14-A

EMB,1

In MB, at most one message transfer is happening at any given moment


A single transfer may address several receivers
With switched LAN, several message transfers may be occurring simultaneously
A single transfer addresses, most of the time, just a single receiver
With EMB, most messages are send to both EMB,0 and EMB,1. This is done
in order to improve reliability and is known as mirroring
Soc Classification level
52
Nokia Siemens Networks

RN28126EN13GLN0

Exercise: BSC interrogation


MSC

BTS

ET.
ET.
ET.
ET.
SGSN ET.

ET.
ET.
ET.
ET.
...
ET.

..

..
..
..

Soc Classification level


53
Nokia Siemens Networks

RN28126EN13GLN0

..

..

NMS

Speech circuits

BSC
GSWB

FR

Circuit Group Full Rate


ETPCM-36

ET-36

TCSM

FR
FR

TCPCM-1
TCPCM-2
TCPCM-3

HS4 TCPCM-1
ETPCM-37

ET-37

Circuit Group HS4

Soc Classification level


54
Nokia Siemens Networks

RN28126EN13GLN0

TCSM

MSC
CCSPCM-0
CCSPCM-1
CCSPCM-2

CCSPCM-3

CCS7 signalling

MSC

BSC

BSSAP

BSSAP

SCCP

SCCP

MTP

Soc Classification level


55
Nokia Siemens Networks

RN28126EN13GLN0

TCSM

MTP

A Interface using SIGTRAN protocol stack


BSC

MSC

BSSAP

BSSAP

SCCP

SCCP

M3UA

M3UA

SCTP

SCTP

Sigtran

IP

Ethernet

Soc Classification level


56
Nokia Siemens Networks

RN28126EN13GLN0

IP

Ethernet

Sigtran - Signalling over IP


Sigtran defines a standardized way of carrying any SS7
signalling over IP networks
Defines retransmission and reordering functionalities
Physical layer can be any layer 1 technology

Sigtran signalling
stack

Application

Signalling
adaptation

M3UA
SCTP

Transport layer

IP

Physical layer

Ethernet/SDH/etc
.

Soc Classification level


57
Nokia Siemens Networks

RN28126EN13GLN0

Application
can be
ISUP, BICC,
SCCP, etc.

Stream Control Transmission Protocol ( SCTP)


Services by SCTP:
Application

SCTP

IP

provides reliable data transfer between two


IP end points
It offers acknowledged error-free nonduplicated transfer of datagrams
(messages).
Detection of data corruption, loss of data and
duplication of data is achieved by using
checksums and sequence numbers.
A selective retransmission mechanism is
applied to correct loss or corruption of data.

L2
L1
Soc Classification level
58
Nokia Siemens Networks

RN28126EN13GLN0

M3UA MTP3 User Adaption Layer


Different adaptation layers possible
- M2UA (MTP2 user adaptation layer)
- M3UA (MTP3 user adaptation layer)
- SUA (SCCP user adaptation layer)
M3UA supported in the 1st implementation of Rel4
M3UA (MTP3 User Adaptation) provides MTP3 user
adaptation for upper layers to use
MAP

Soc Classification level


59
Nokia Siemens Networks

TCAP

MAP

SCCP

TCAP

M3UA

SUA

SCTP

SCTP

IP

IP

RN28126EN13GLN0

Sigtran Terms and Concepts


Addressing
based on
SPCs!

DX200
Signalling point A

Signalling point B

Association Set (up to 16 associations)


MSC (Server)

SCTP Association

CCSU_0

BSC (Client)
BCSU_0

IP

CCSU_1
CCSU_2

BCSU_1
BCSU_2

CM

MCMU

SPC_1

IP Addresses

SPC_2

Signaling Link Set can only contain one "Sigtran


link". "Sigtran link" consists of one SCTP association
set.
Association is identified by the computer unit and
destination address. Only one association allowed per
computer unit

Soc Classification level


60
Nokia Siemens Networks

RN28126EN13GLN0

Sigtran Terms and Concepts

Soc Classification level


61
Nokia Siemens Networks

RN28126EN13GLN0

SIGTRAN vs TDM SS7

Soc Classification level


62
Nokia Siemens Networks

RN28126EN13GLN0

Abis-IF structure
BTS
1+1+1

BSC
GSW

TRXSIG BCFSIG

ET

D-BUS
B
C
F

TCH
TRU

ET
ET

Abis Structure
1 2

OMU MCMU BCSU


Abis Interface
compressed allocation
1 2 3 4
0
1
2
3
4

Soc Classification level


63
Nokia Siemens Networks

5 6

7 8

fixed CCITT frame data


TRXSIG 1BCFSIG TCH 2 TCH 3
TCH 4 TCH 5 TCH 6 TCH 7
TRXSIG 2TCH 1 TCH 2 TCH 3
TCH 4 TCH 5 TCH 6 TCH 7

RN28126EN13GLN0

3 4

5 6

7 8

0
fixed CCITT frame data
TCH 1 TCH 2 TCH 3
1
2 TCH 4 TCH 5 TCH 6 TCH 7
3
4
5
TCH 1 TCH 2 TCH 3
6 TCH 4 TCH 5 TCH 6 TCH 7
7
8
TCH 1 TCH 2 TCH 3
9
10 TCH 4 TCH 5 TCH 6 TCH 7
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25 TRXSIG 1
26 TRXSIG 3
27 TRXSIG 5
28
29
30
31 BCFSIG

TRX 1
TRX 3
TRX 5

Exercise: Interrogation of signalling and circuit


switched traffic
A-IF
CCS7

Abis-IF
Lap-D

BSC
ET.

GSW

ET.

ET.

ET.

ET.

ET.

ET.

ET.

ET.

ET.

..

Soc Classification level


64
Nokia Siemens Networks

RN28126EN13GLN0

Radio link measurements


UL: Rx Level
DL: Rx Level
Rx Quality
Rx Quality
MS-BTS Distance
Adjacent cell Rx Levels

BSC

BSC

DL
UL

BTS
Adjacent cells
Serving cell
Soc Classification level
65
Nokia Siemens Networks

RN28126EN13GLN0

Reporting in
every 480 ms
(960 ms)

Handover cases
BSC
MSC
(1)
(2)
BSC

MS

(3)
(4)
MSC

BSC

BTS

Soc Classification level


66
Nokia Siemens Networks

RN28126EN13GLN0

Power control in DX 200 BSC


Power control for MS and BTS (non-BCCH)
Averaging and threshold comparison as in
handover cases
Causes for POC:
high/low signal quality (ul/dl)
high/low signal level (ul/dl)

New power level determination by HOC&POC


algorithm
MS TX Power Level

BTS

MS Power Control
BS Power Control

Soc Classification level


67
Nokia Siemens Networks

RN28126EN13GLN0

AMR Progressive Power Control Background


In normal Power Control algorithm the quality thresholds for quality
based PC are not changing according to actual transmitting power
Example:
Quality
Rxqual

BER %

<0.2

0.2 - 0.4

0.4 - 0.8

0.8 - 1.6

1.6 - 3.2

3.2 - 6.4

6.4 - 12.8

>12.8

Power
15
30

14
28

13
26

12
24

11
22

10
20

9
18

8
16

7
14

6
12

5
10

4
8

pc upper threshold dl Rx qual AMR FR (UDRF)


pc lower threshold dl Rx qual AMR FR (LDRF)
Optimum quality, No need to change transmitting power
Soc Classification level
68
Nokia Siemens Networks

RN28126EN13GLN0

3
6

2
4

1
2

0 Power level
0 Attenuation dB

AMR Progressive Power Control - Concept


Instead of using constant RX_QUAL threshold values, progressive power
control uses higher RX_QUAL threshold values for higher TX power levels

Main principle of Progressive Power Control


Soc Classification level
69
Nokia Siemens Networks

RN28126EN13GLN0

AMR Progressive Power Control - Concept


Instead of using constant RX_QUAL threshold values, progressive power
control uses higher RX_QUAL threshold values for higher TX power levels

Main principle of Progressive Power Control


Soc Classification level
70
Nokia Siemens Networks

RN28126EN13GLN0

AMR Progressive Power Control - Concept


Instead of using constant RX_QUAL threshold values, progressive power
control uses higher RX_QUAL threshold values for higher TX power levels

Main principle of Progressive Power Control


Soc Classification level
71
Nokia Siemens Networks

RN28126EN13GLN0

Frequency hopping
Base Band Hopping:
RTSL
TRX-1

0
B

1
0

2
0

B = BCCH timeslot. It does


not hop.

f2

f3

f4

TRX-2 0

TRX-3 1

TRX-4 2

f1

1
2

2
2

3
3

Time slots 1...7 of all


TRXs
hop over MA(f1, f2, f3, f4).
This hopping group uses
HSN-2.
MAIOs have to be different
between
same RTSLs in same
hopping group.

Time slot 0 of TRX-2,-3,-4 hop over MA (f2, f3, f4).


This hopping group uses HSN-1.

Synthesized Hopping:

B = BCCH timeslot. TRX does not hop.

TRX-1 B

fa

f1,
f2,
f3,
f4,

.....

TRX-2 0

TRX-3 1

Soc Classification level


72
Nokia Siemens Networks

f1,
f2,
f3,
f4,

0
0
1
1

(fb)

(fc)

RN28126EN13GLN0

Non - BCCH TRXs are hopping over


the MA -list (f1,f2,f3,...,fn) attached to the cell.
MAIOs have to be different
between
same RTSLs in same
hopping group.
Only one hopping group. Only HSN-1 is
meaningful.

Logical Channel Types

LOGICAL
CHANNELS
COMMON
CHANNELS

DEDICATED
CHANNELS

COMMON
CONTROL
CHANNELS

BROADCAST
CHANNELS

FCCH

SCH

BCCH

Soc Classification level


73
Nokia Siemens Networks

CBCH

PCH

RN28126EN13GLN0

RACH

DEDICATED
CONTROL
CHANNELS

AGCH SDCCH SACCH FACCH

TRAFFIC
CHANNELS

TCH

Data

Exercise: Cell parameter interrogation

POC

HOC

BSC

BTS/SEG
FHS

CH

Soc Classification level


74
Nokia Siemens Networks

RN28126EN13GLN0

Das könnte Ihnen auch gefallen