Sie sind auf Seite 1von 4

TESTING & EVALUATION CAPABILITIES

ELECTRICAL RESEARCH AND DEVELOPMENT ASSOCIATION


(Accredited by NABL, Govt. of India. & INTERTEK Testing and Certification (ASTA BEAB), U.K)

SWITHGEAR LABORATORY
ERDA Road, GIDC, Makarpura, Vadodara390 010, India
Tel. +91(0265) 2642942, 2642964, 2642377,
3043128-3043131, Fax: +91 (0265) 2638382, 2644923
E-mail:g.som@erda.org; mukesh.shah@erda.org; erda@erda.org
Web: http://www.erda.org

Navi Mumbai
R- 336, TTC Industrial Area, Near Rabale Railway Station, Navi Mumbai 400 701
Tel.+91 022 27606212-14; e-mail:berda@bom8.vsnl.net.in; Web: www.erda.org
Registered Office

Delhi Office

Sonepat Site

Rajahmundry Site

Savli Laboratory

Brabourne Stadium,
87, Veer Nariman Road,
Mumbai - 400 020,
Telefax: (022) 22820622,
22815376,
E-mail:
berda@bom8.vsnl.net.in

F-28, Pankaj Central


Market, Local Shopping
Complex, IP Extension,
Patparganj Area,
Delhi - 110 092
Telefax: (011) 42175634,
E-mail:erdadel@erda.org

1410, HSIIDC
Industrial Estate, RAI,
Sonepat - 130 129
Haryana
Telefax: 0130-2236302
E-mail: erdaspt@erda.org

Plot No.5;
House No. 78/13/5, SBI
Colony, Shyamala Nagar
Rajahmundry - 533 103
Ph: 0883-2421431
E-mail : erdarjm@erda.org

K-V2/A, GIDC,
Savli, Manjusar,
Dist. Vadodara
Phone:02667 264347/49,
Fax. 02667 264348
E-mail: erdasvl@erda.org

FOUR DECADES OF SERVICE TO INDUSTRY AND UTILITIES

Introduction
ERDA has recently established temperature-rise test facilities up to 20kA, Time-current characteristics up to 40kA, Electrical endurance
test up to 2.5kA at 690V, Mechanical endurance test for HT Circuit Breaker up to 145kV, 24kV Impulse Generator, Feeder Load Unit (3
nos.).
Switchgear test facilities for type tests and certification of various electrical products are accredited by Intertek testing and certification,
(ASTA), UK for Indian customers & for the export of electrical products worldwide. ERDA's switchgear laboratory is also accredited by
National Accreditation Board for Testing and Calibration Laboratory (NABL), Govt. of India and recognized by Bureau of Indian Standards
(BIS), UL, USA & CSA.
ERDA has one of the largest IP 40 ton test facilities in Asia.
ERDA has also established an Online Short Circuit Testing Laboratory for 120kA, 575V at Savli and 50kA, 500V at Makarpura, for testing
of Switchgear & Controlgear products, Distribution Transformers, Current Transformers & Cables.

Recognitions
Intertek Testing and Certification Ltd., (ASTA-BEAB),UK
Underwriters' Laboratories (UL) , USA

Utilities of Gujarat, Maharashtra, Rajasthan, Madhya Pradesh,


Punjab, Haryana, Jammu & Kashmir, Tamil Nadu, Uttar Pradesh
and Chhattisgarh etc.

National Accreditation Board for Testing and Calibration


Laboratories (NABL), Govt. of India, Dept. of Science &
Technology
Bureau of Indian Standards (BIS)
Govt. of India, Ministry of Scientific & Industrial Research
Govt. of India, Ministry of Finance, Dept. of Revenue
Govt. of India, Director General Factory Advice & Labour
Institute
Govt. of Gujarat, Chief Inspector of Steam Boilers and Smoke
Nuisances
Govt. of Maharashtra, Charity Commissioner
Govt. of India, Petroleum Explosive and Safety Organization,
Nagpur

20kA High Current Source

Major Infrastructure
Short circuit making & breaking capacities 120 kA, 570V and
50 kA, 525 V for Switchgear products

Ring wave cum current surge generator. Current surge 3000A,8/20 sec, Ring wave - 250A,0.5 sec 100 kHz

Short time withstand current test 120 kA for 1 second or 70


kA for 3 second at Savli and 50 kA for 1 Second, at Makarpura

Computerized Single phase & Three Phase Relay testing kit


Feeder load unit 3 Nos. (Each with 8 ways outgoing feeder)

20kA & 10kA, stabilized High Current source for temperature


rise test

Environment (Humidity) chamber: - 40C to +180C, Size: 950


mm x 1000 mm x 950 mm

Time current characteristics up to 40kA, 40V

Cold chamber : - 65C, Size : 580 mm x 550 mm x 1120 mm

Mechanical endurance test set up for HT circuit breaker upto


145 kV class

IP test ( Degree of Protection ): 40 Ton, Size: 6.8 Mtr x 5.8 Mtr. x


5.0 Mtr

170 channel computerized temperature scanner

a) Impulse Test 1600 kV, 80 kJ

Electrical endurance and Making & Breaking setup, 2.5kA at


415V, 2 kA at 690V, 1 kA at 415V, - 200A at 415V

b) High Voltage one minute power frequency test

24kV, 1.2/50s Impulse generator

dry & wet 700 kV, 350 kVA

Electrical Research & Development Association, Vadodara

Products Covered
Sr.
No.

Standard Title / Product

IS / IE CStandard

1.

Specification for low voltage switchgear and control gear Circuit breakers

IS/IEC:60947- 2- 2003

2.

Specification for low voltage switchgear and control gear switches, disconnectors,
switch disconnectors and fuse combination units

IS/IEC:60947- 3 -1999

3.

Specification for low voltage switchgear and controlgear contactors and motor starters

IS/IEC:60947- 4 -1- 2000

4.

Specification for low voltage switchgear and controlger Control circuit devices and
switching elements

IS/IEC:60947- 5 -1- 2003

5.

Electrical accessories - Circuit breakers for over current protection for household and
similar installations

IS/IEC:60898 - 1-2002 & 2 -2003


IEC:60898-1& 2- 2003

6.

Residual current operated circuit breakers without integral over current protection
(RCCB)

IS:12640 -1- 2008


IEC:61008-1-2012

7.

Residual current operated circuit breakers with integral over current protection (RCBO)

IS:12640 - 2-2008
IEC:61009 -1-2012

8.

Low voltage switchgear and controlgear assemblies

IS:8623 -1,2 & 3 -1993


IEC:61439-1&2-2011

9.

Carriers and based in rewirable type electric fuses for voltages up to 650V-specification IS:2086-1993

10. Low-voltage switchgear and controlgear assemblies - Particular requirements for bus
bar trunking systems (bus ways)

IEC:61439-6 -2012

11. Low-voltage switchgear and controlgear assemblies - Particular requirements for


low-voltage switchgear and controlgear assemblies intended to be installed in places
where unskilled persons have access for their use - distribution boards

IEC:61439-3-2012

12. Low -voltage switchgear and controlgear assemblies - Particular requirements for
assemblies for construction sites (ACS)

IEC:61439 -4 - 2012

13. Specification for high voltage fuses-current limiting fuses

IS:9385 -1- 1979


IS:9385 -2-1980

14. Specification for alternating current disconnector (isolators) and earthing switches for
voltages above 1000 V - General and definitions

IS:9921-1- 1981, IS 9921-2- 1982,


IS:9921-3-1982, IS 9921-4- 1985

15. Specification for alternating current switches for voltages above 1000V - General and
definitions

IS:9920-1- 2002, IS 9920-2- 2001

16. Specification for electric power connectors

IS:5561 : 1970

17. Classification of degree of protection provided by enclosure of electrical equipment

IS/IEC:60529-2001

18. Degree of protection provided by enclosures (IP code)

IEC:60529-2001

19. Degrees of protection provided by the intergral design of rotating electrical machines
(IP code) classifications

IEC:60034 -5- 2006

20. High voltage alternating current circuit breakers

IEC:62271-100- 2012

21. Alternating current disconnectors and earthing switches

IEC:62271-102-2013

22. AC metal enclosed switchgear and controlgear for rated voltages above 1kV and upto
and including 52kV

IEC:62271-200-2011

23. Specification for electrical relays - Insulation tests

IS:12083- 2-1-1986

24. Basic environnemental testing procedures Dry heat

IEC:68 - 2 - 2- 2007

25. Basic environmental testing procedures Damp heat cyclic

IEC:68 - 2 -30-2005

26. Specification for low voltage fuses for voltages not exceeding 1000V ac or 1500V dc

IS:13703 -1- 1993,


IS:13703- 2-1&2-1993
IEC:60269-1-2009
IEC:60269-2-2010

27. Fire hazard testing - Glow wire test apparatus and common test procedure

IEC:60695-2-10 -2000

28. Switches for rated voltages above 1kV and less than 52kV

IEC:62271 -103-2011

Electrical Research & Development Association, Vadodara

Some Important Visitors


Mr. Sung Puay Kiang of M/s. Sunlight Electrical Pte Ltd.,
Singapore
Mr. Kullakavandar of M/s. Pacific MK Corporation, Malaysia
Mr. Nguyen Thanh Dien of M/s. DUY HAO Engineering Co.,
Ltd., Malaysia
Mr. Darren Ng of Furutec Electricals SDN BHD, Malaysia
Mr.Maximo S. Espino of M/s. Industrial Electrical Project,
Kuwait
Mr. Omar Salem of M/s. Arabian Gulf Industrial Co. Kuwait
Mr.Bui Hong Phuoc of M/s. HONG THINH Jont Stock Company,
Vietnam
Mr. Khalid Hashem of M/s. ABB Arab, Egypt
Mr. Rajesh K Lakhwani of Al Rebou Elct. Switchgear, Abudhabi
Mr. Thiagarajan Ponmani of M/s.Alfanar Electrical Systems,
Riyadh, K.S.A
Mr. P. K. Kashyap of Matrix Switchgear Industries L.L.C., Sharjah
Mr. Prakash of M/s. Safety Electrical Trading Co. W.L.L., UAE
Mr. K. Shrinivas of Powertech Switchgear Industries F.Z.E., UAE
Mr. Adrian Sheridan of Powerbar Gulf LLC RAK Factory, UAE
Mr. P. K. Basu of Al Ishraf Electrical & Sanitary CONC. Co. L.L.C.
UAE

Mr. Sami Farraj, of M/s. Farraj Trading & Manufacturing Co.,


UAE
Mr. V.M.Kareem Gani of M/s. ETA-PCS SWITCHGEAR
MANUFACTURING L.L.C.,UAE

Humidity Test Chamber

Export of Electrical Products


ERDA's test facilities can be utilized for certification of products to be exported to European and Middle East markets, under the ASTA
mark. Intertek testing and certification, UK has accredited ERDA test facilities for testing of electrical products for issuing ASTA-BEAB
certificates.

Major Testing Facilities

40 TON IP Test Facility, a Unique Facility

40kA High Current Source

4kA Electrical Endurance Test Control Room

24kVp Impulse Test Facility

For more details, please contact: g.som@erda.org; mukesh.shah@erda.org

Das könnte Ihnen auch gefallen