VIII-210
SCOPE
VIII-230
VIII-231
This Appendix provides requirements for using phosphor imaging plate (photostimulable luminescent phosphor) as an alternative to film radiography.
Radiography using phosphor imaging plate may be performed on materials including castings and weldments
when the modified provisions to Article 2 as indicated
herein and all other requirements of Article 2 are satisfied.
The term film, as used within Article 2, applicable to performing radiography in accordance with this Appendix, refers to phosphor imaging plate. ASTM E2007, Standard
Guide for Computer Radiography, may be used as a guide
for general tutorial information regarding the fundamental and physical principles of computed radiography
(CR), including some of the limitations of the process..
VIII-220
VIII-221
VIII-234
GENERAL REQUIREMENTS
VIII-260
PROCEDURE REQUIREMENTS
VIII-262
CALIBRATION
DENSITOMETER AND STEP WEDGE
COMPARISON FILM
The requirements of T-262 are not applicable to phosphor imaging plate radiography.
VIII-270
VIII-277
EXAMINATION
USE OF IQIS TO MONITOR
RADIOGRAPHIC EXAMINATION
VIII-225
The requirements of T-225 are not applicable to phosphor imaging plate radiography.
33
2013 SECTION V
2013 SECTION V
VIII-287
VIII-281
VIII-288
EVALUATION
SYSTEM-INDUCED ARTIFACTS
IMAGE BRIGHTNESS
VIII-283
VIII-290
VIII-291
VIII-284
13
DOCUMENTATION
DIGITAL IMAGING TECHNIQUE
DOCUMENTATION DETAILS
IQI SENSITIVITY
INTERPRETATION
The digital image shall be free of system-induced artifacts in the area of interest that could mask or be confused
with the image of any discontinuity.
VIII-282
13
VIII-277.3 Shims Under Hole IQIs. For welds with reinforcement or backing material, a shim of material radiographically similar to the weld metal and/or backing
material shall be placed between the part and the IQIs,
such that the image brightness at the body of the IQI is
judged to be equal to or greater than the image brightness
at the area of interest for a negative image format. This image brightness requirement is reversed for a positive image format.
The shim dimensions shall exceed the IQI dimensions
such that the outline of at least three sides of the IQI shall
be visible in the radiograph.
VIII-280
MEASURING SCALE
EXCESSIVE BACKSCATTER
13
ARTICLE 2
ARTICLE 2
13
VIII-293
DELETED
35
2013 SECTION V