Sie sind auf Seite 1von 9

DADIANGAS

CITY HEIGHTS

THE SITE

TO PUROK MALAKAS

TO DADIANGAS CITY HEIGHTS

TO SORIANO SUBD.

BLK. 8

VICINITY MAP
NOT TO SCALE
PROJECT: PROPOSED RESIDENTIAL
BUILDING
LOCATION: #010 SEBASTIAN ST.,
PARADISE SUBD., G.S.C.

OWNER:

CONTENTS:

SHEET NO.

VICINITY MAP

E-2

MARK RANDOLPH T. ARNAEZ


ELECTRICAL ENGR.:
ENGR. JHAYSON ALLEN S. TAN

3.5

4.5

4.5

1.5

1.5

10.5

.8

5.5

4.5

14

FLOOR PLAN
SCALE 1:75
PROJECT: PROPOSED RESIDENTIAL
BUILDING
LOCATION: #010 SEBASTIAN ST.,
PARADISE SUBD., G.S.C.

FLOOR AREA: 138m 2


OWNER:

CONTENTS:

SHEET NO.

FLOOR PLAN

E-3

MARK RANDOLPH T. ARNAEZ


ELECTRICAL ENGR.:
ENGR. JHAYSON ALLEN S. TAN

2
G

H
L
M
G

J
L
H IJ
E FG
K

M
E

N
P
O
Q

A
B

C
O
B

AE
BCD
A

D
A

LIGHTING LAYOUT
SCALE 1:100
PROJECT: PROPOSED RESIDENTIAL
BUILDING
LOCATION: #010 SEBASTIAN ST.,
PARADISE SUBD., G.S.C.

OWNER:

CONTENTS:

SHEET NO.

LIGHTING LAYOUT

E-5

MARK RANDOLPH T. ARNAEZ


ELECTRICAL ENGR.:
ENGR. JHAYSON ALLEN S. TAN

12

11

8
10

13

POWER LAYOUT
SCALE 1:100
PROJECT: PROPOSED RESIDENTIAL
BUILDING
LOCATION: #010 SEBASTIAN ST.,
PARADISE SUBD., G.S.C.

OWNER:

CONTENTS:

SHEET NO.

POWER LAYOUT

E-6

MARK RANDOLPH T. ARNAEZ


ELECTRICAL ENGR.:
ENGR. JHAYSON ALLEN S. TAN

LEGEND:
300 W CHANDELIER

CONVENIENCE OUTLET

40 W FLUORESCENT LIGHT

PANEL BOARD

20 W FLUORESCENT LIGHT

CIRCUIT HOMERUN

32 W CIRCULAR FLUORESCENT LIGHT

LIVE LINE

20 W PIN LIGHT

(SINGLE, TWO OR THREE) GANG


SWITCH

4 kW MICROWAVE
5 kW ELECTRIC RANGE
6 kW WASHING MACHINE
3 kW WATER HEATER
1.5 hp WATER PUMP
2 hp AIR CONDITIONING UNIT (ACU)
PROJECT: PROPOSED RESIDENTIAL
BUILDING
LOCATION: #010 SEBASTIAN ST.,
PARADISE SUBD., G.S.C.

OWNER:
MARK RANDOLPH T. ARNAEZ
ELECTRICAL ENGR.:
ENGR. JHAYSON ALLEN S. TAN

CONTENTS:

SHEET NO.

LEGEND

E-4

GENERAL NOTES/SPECIFICATION:
ALL WORK SHALL CONFORM WITH THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE RULES
AND REGULATION OF THE ENFORCING AUTHORITY AND THE LOCAL LIGHTS AND POWER COMPANY.
ALL MATERIALS TO BE USED SHALL BE USED SHALL BE BRAND NEW AND OF THE APPROVED TYPE AS
SPECIFIED ON PLANS.
SERVICE ENTRANCE SHALL BE 2 80 mm THW CU. WIRE WITH 1 14 mm GROUND CU. WIRE IN
50 mm RIGID METALLIC CONDUIT (RMC).
WIRING SHALL BE CONCEALED USING A RIGID METALLIC CONDUIT (RMC).
ALL WORKS SHALL BE UNDER THE DIRECT SUPERVISION OF THE DULY LISENCED ELECTRICAL ENGINEER
OR MASTER ELECTRICIAN.

PROJECT: PROPOSED RESIDENTIAL


BUILDING
LOCATION: #010 SEBASTIAN ST.,
PARADISE SUBD., G.S.C.

OWNER:
MARK RANDOLPH T. ARNAEZ
ELECTRICAL ENGR.:
ENGR. JHAYSON ALLEN S. TAN

CONTENTS:

SHEET NO.

GENERAL NOTES/

E-1

SPECIFICATION

LOAD SCHEDULE:
Circuit #

Wires

Ground Wire

Conduit

Description
Lighting Outlets

Voltage Current
230 V

1.97 A

Power Circuit Breaker Size


452 W

15 AT

2 - 2.0 mm

-----

15 mm

Lighting Outlets

230 V

2.09 A

480 W

15 AT

2 - 2.0 mm

-----

15 mm

6 Convenience Outlets

230 V

4.70 A

1080 W

20 AT

2 - 3.5 mm

1 - 3.5 mm

15 mm

7 Convenience Outlets

230 V

5.48 A

1260 W

20 AT

2 - 3.5 mm

1 - 3.5 mm

15 mm

7 Convenience Outlets

230 V

5.48 A

1260 W

20 AT

2 - 3.5 mm

1 - 3.5 mm

15 mm

4 kW Microwave

230 V

17.39 A

4000 W

30 AT

2 - 5.5 mm

1 - 5.5 mm

15 mm

5 kW Electric Range

230 V

17.39 A

4000 W

30 AT

2 - 5.5 mm

1 - 5.5 mm

15 mm

6 kW Washing Machine

230 V

26.09 A

6000 W

70 AT

2 - 22 mm

1 - 8.0 mm

25 mm

3 kW Water Heater

230 V

13.04 A

3000 W

20 AT

2 - 3.5 mm

1 - 3.5 mm

15 mm

10

3 kW Water Heater

230 V

13.04 A

3000 W

20 AT

2 - 3.5 mm

1 - 3.5 mm

15 mm

11

1.5 hp Water Pump

230 V

10.00 A

2300 W

30 AT

2 - 5.5 mm

1 - 5.5 mm

15 mm

12

2 hp Air Conditioning Unit (ACU)

230 V

12.00 A

2760 W

30 AT

2 - 5.5 mm

1 - 5.5 mm

15 mm

13

2 hp Air Conditioning Unit (ACU)

230 V

12.00 A

2760 W

30 AT

2 - 5.5 mm

1 - 5.5 mm

15 mm

IT = 140.67 A

USE 175 AT Moulded Case Circuit Breaker (MCCB)

IW = IT + (0.25) (Highest Rated Motor)

USE 2 80 mm THW CU. WIRE

IW = 140.67 + (0.25) (26.09 A)

USE 1 14 mm GROUND CU. WIRE

IW = 147.19 A

USE 50 mm RMC

ICB = IT + (1.75) (HRM)


ICB = 140.67 + (1.75) (26.09 A)
ICB = 186.32 A

PROJECT: PROPOSED RESIDENTIAL


BUILDING
LOCATION: #010 SEBASTIAN ST.,
PARADISE SUBD., G.S.C.

OWNER:
MARK RANDOLPH T. ARNAEZ
ELECTRICAL ENGR.:
ENGR. JHAYSON ALLEN S. TAN

CONTENTS:

SHEET NO.

LOAD SCHEDULE

E-7

DESIGN ANALYSIS:
LIGHTING CIRCUIT: 24 x FLOOR AREA = 24 x 138 m2 = 3312 W
SMALL APPLIANCE CIRCUIT:

1500 W

LAUNDRY CIRCUIT:

1500 W

BATHROOM CIRCUIT:

1500 W
7812 W

IT = 141.32 A

- 3000 W

IW = IT + (0.25) (Highest Rated Motor)

4812 W

IW = 141.632 + (0.25) (26.09 A)

x 0.35

IW = 147.84 A

1684.2 W

ICB = IT + (1.75) (HRM)

+ 3000 W

ICB = 141.32 + (1.75) (26.09 A)

4684.2 W
4 kW MICROWAVE:

4000 W

5 kW ELECTRIC RANGE:

4000 W

6 kW WASHING MACHINE:

6000 W

2 - 3 kW WATER HEATER:

6000 W

1.5 hp WATER PUMP:

2300 W

2 - 2 hp AIR CONDITIONING UNIT (ACU):

5520 W

ICB = 186.97 A
USE 175 AT Moulded Case Circuit Breaker (MCCB)
USE 2 80 mm THW CU. WIRE
USE 1 14 mm GROUND CU. WIRE
USE 50 mm RMC

27820 W
TOTAL POWER = 27820 W + 4684.2 W = 32504.2 W
IT = 32504.2 W / 230 V
IT = 141.32 A

PROJECT: PROPOSED RESIDENTIAL


BUILDING
LOCATION: #010 SEBASTIAN ST.,
PARADISE SUBD., G.S.C.

OWNER:

CONTENTS:

SHEET NO.

DESIGN ANALYSIS

E-8

MARK RANDOLPH T. ARNAEZ


ELECTRICAL ENGR.:
ENGR. JHAYSON ALLEN S. TAN

RISER DIAGRAM/PANEL BOARD:

USE 2 80 mm THW COPPER WIRE WITH


1 14 mm GROUND COPPER WIRE IN
50 mm RIGID METALLIC CONDUIT (RMC)
175 AT
15 AT

15 AT

20 AT

20 AT

20 AT

30 AT

30 AT

70 AT

20 AT

30 AT

10

30 AT

30 AT

1
3
5

11
13

2
4
6

12

30 AT

PROJECT: PROPOSED RESIDENTIAL


BUILDING
LOCATION: #010 SEBASTIAN ST.,
PARADISE SUBD., G.S.C.

OWNER:
MARK RANDOLPH T. ARNAEZ
ELECTRICAL ENGR.:
ENGR. JHAYSON ALLEN S. TAN

CONTENTS:

SHEET NO.

RISER DIAGRAM/

E-9

PANEL BOARD