Beruflich Dokumente
Kultur Dokumente
Tutorial 4
Tri 1/10
Tutorial 4
Question 1
In a regulated flyback converter with a 1: 1 turns ratio, Vo = 12V, Vd is 1224V, Pload is 6 60W, and the
switching frequency fs = 200KHz. Calculate the maximum value of the magnetizing inductance Lm that
can be used if the converter is always required to operate in a complete demagnetization (equivalent to a
discontinuous conduction) mode. Assume ideal components.
Question 2
Figure below shows a switchmode power supply that is to be designed with the following specifications:
Vd 48V 10%
Vo 5V ( regulated)
f s 100kHz
Pload 15 50W
Question 4
In the pushpull converter as shown, assume the losses to be zero and each switch duty ratio to be 0.25.
The transformer has a finite magnetizing inductance and im is the magnetizing current.
(a) At a large load where iL (N2/N1) >> im, draw the im, iD1 and iD2 waveforms.
(b) At essentially no load, draw the im waveform and show that the peak value of im is higher than in
part (a)