Sie sind auf Seite 1von 15

DC-T6/DC-N6

XP and Doppler Software Recovery Instruction

Mar 4, 2011

Page 1 of 15

Contents
Page
BEFORE UPGRADE ..................................................................................................................................................3
STEP ONE - DATA BACKUP AND PREPARATION ...........................................................................................4
STEP TWO - CHANGE BIOS SETTINGS TO BOOT FROM USB CD-ROM....................................................5
STEP THREE - WINDOWS XP SYSTEM UPDATE .............................................................................................9
STEP FOUR - DOPPLER UPDATE ....................................................................................................................... 11
STEP FIVE - CHANGE LANGUAGE SETTING ................................................................................................. 13
STEP SIX SET CONFIGURATION TYPE AND PRODUCT TYPE ............................................................... 14
STEP SEVEN - LOAD PRESET DATA ................................................................................................................. 15

Mar 4, 2011

Page 2 of 15

Before Upgrade
(1) You need following items:

Mar 4, 2011

1.

DISC 1: Windows XP, Bootable DVD

2.

DISC 2: Application Software DVD

3.

USB Flash Drive for data backup(500M


free space minimum)

Page 3 of 15

STEP ONE - Data Backup and Preparation


(1) Back up user preset data.

User preset data may be erased during the upgrade. Mindray strongly
recommends backing up user presets.

The Hospital Information under the Region tab, and all the network settings
including DICOM settings, will not be saved in the preset data file. You could capture
screenshots of the setting pages to keep a copy of them.
How to back up user presets to a USB Flash Drive:
Plug a USB Flash Drive into the USB port, press SETUP key on the keyboard  [Manage settings] 
[Export all] (on the bottom left). Select USB drive (usually it is Drive F).
). Type a name for the preset data
file and click on [OK].
(2) Back up patient data and Option keys .

Even though patient data including patient info, images, cine loops and reports
and Option keys usually will not be affected during upgrade, for safety consideration,
Mindray recommends having all the patient data and Option keys backed up before
upgrade.
Please refer to operators manual for detailed instructions of how to back up patient data.
The Option Keys locate in C:\M7
M7\key.
Note: The upgrade takes around 20 minutes. Please always keep the DC-T6/DC
T6/DC-N6 connected to AC
power during the upgrade.

Mar 4, 2011

Page 4 of 15

STEP TWO - Change BIOS Settings to Boot from USB CDCD-ROM


Notice: There are two methods to boot from USB CD-ROM.
The first and commendatory method is using shortcut key B:
(1) Turn on the machine. Open the DVD/CD Drive disk compartment. Then hold and press B key
when DC-T6/DC-N6 displays the first startup screen.

(2) System will display Boot Action Menu like below.


Select the sixth items booting form USB-CD/DVD ROM. Different device may appear different
content. We only take Optiarc DVD RW AD-7260S USB Device for example.

Mar 4, 2011

Page 5 of 15

The second method is using Del key:


(1) Turn on equipment. Repeatedly press Del key then the unit displays the first startup screen.

(2) System will pop up a dialog box indicating you to input password: 58125837.

(3) Use arrow keys left and right to select [Chipset] menu.
(4) Use arrow key up and down to view the content of [USB Configuration].
If there is [Only Mindray keyboard],use arrow key up and down to select [Only Mindray keyboard].
Press Spacebar button on the machine keyboard to set [Only Mindray keyboard] to Disabled.

Mar 4, 2011

Page 6 of 15

Notice: If there is [USB Port Manual Control] In New Bios version, use arrow keys up and down to
select[USB Port Manual Control].Press spacebar button on M7 keyboard to set [USB Port Manual
Control] to Enabled, then press spacebar button to set USB Port 0---USB Port 7 to Enabled.

Mar 4, 2011

Page 7 of 15

(5)Use arrow keys left and right to select [Boot] menu, in number 0 device column, press Spacebar
button several times until [USB CD-ROM Drive] is displayed.

Notice: For new Bios version(08.03.31),in [Boot] menu, select Number 0 device column and press
Spacebar button several times until [USB CD-ROM Drive] is displayed. If the below column
appears [USB CD-ROM Drive],use Spacebar button to disappear[USB CD-ROM Drive] .

(6) Use arrow keys left and right to select [Exit] menu, select [Save Settings and Reboot], press Enter
key and then press Y key to reboot the equipment.

Mar 4, 2011

Page 8 of 15

STEP THREE - Windows XP System Update


(1) System is restarting. Shortly after Windows XP system booting picture disappears, a DOS window
displays the message below:

(2) Press any key on alphanumeric keyboard to continue. XPE installation process lasts about 15 minutes.
Please do not interrupt the installation.
(3) After installation is complete, A DOS message like below is displayed:

(4) Press any key on alphanumeric keyboard to restart the system.


(5) If you take the second method mentioned above to change the Boot Device Priority booting from
USB-CD ROM, you have to resume the Boot Device Priority from SATA 0: When system starts
rebooting, keep pressing B key to enter Boot Action Menu again. Change BIOS settings to boot
from hard disk.
a)

Select [Enter System Setup Utility], and input password 58125837.

b) Select [Chipset] menu, change [Only Mindray keyboard] to Enabled.


c) Go to [Boot] menu, press Spacebar key several times until [SATA 0] is displayed.
d) In [EXIT] menu, save the settings and reboot.

Mar 4, 2011

Page 9 of 15

(6) System restarts. Windows XP Setup Window is displayed.


When it asks to create a user account, please do not change anything, click on [Next] to
continue.

(7) After the setup finishes, system will restart again and enter Windows XP desktop.

Mar 4, 2011

Page 10 of 15

STEP FOUR
FOUR - Doppler Update
(1) Take out DISC 1 and put DISC 2: Application Software into the DVD drive.

Or, if you have all Doppler software files copied to a virus-free USB stick, please connect it
with USB port.
(2) Double click My Computer on the desktop and then double click CD-ROM under Devices with
Removable Storage to open the DVD.

(3) Double click Run on the DVD to start the installation.

(4) The installation process lasts about 10 minutes. If Mindray ECG module is not plugged in, an error
message M7.ECG Recover Failed! will be displayed during the upgrade. Please ignore it. Depends
on the keyboard firmware version, there may be an error message M7.KUG Recover Failed! Please
ignore it as well.
(5) When it asks if you want to delete the user preset, type in N and press Enter key to continue.
Otherwise ,type Y and press Enter key to continue.

Mar 4, 2011

Page 11 of 15

Near the end of recovery ,system appears a tip in red as below

This indicates making a setup of the regulation type and the product type in Doppler after finishing
recovering.
(6) Press Enter key to go back to the operating system. Take out DISC 2, and restart the system.

Mar 4, 2011

Page 12 of 15

STEP FIVE - Change Language Setting


(1) At the login screen, select user name Admin and leave the password area empty then click on
Login.
(2) Press the Setup key on the keyboard  [System Preset]  [Region] tab.

(3) Click on the language drop-down list and change it from English to Chinese then click on [Ok].
(4) Do not click on [Return]. Select [System Preset] again then change the language setting from
Chinese back to English.
(5) Click on [Ok] then click on [Return] to reboot the DC-N6/DC-T6.
Note: This step is used to change the Windows system language setting. Otherwise Chinese characters
may be displayed on the screen.

Mar 4, 2011

Page 13 of 15

STEP SIX Set Configuration Type and Product Type


NoteAfter the Version 01.03.00(Rev35432) EDT004, we can set the Configuration type and the
product type according the actual requirement.
(1) Log in as service .
(2) Press [Setup] on the keyboard [Maintenance] [Set Configuration Type].
(3) Choose the type as your demand.
(4) Clink on [OK] to save you set, then system will reboot automatically.

Mar 4, 2011

Page 14 of 15

STEP SEVEN - Load Preset Data


Generally speaking, new factory default presets have the latest settings for optimal performance. Mindray
recommends loading new factory default presets instead of using presets from previous software.
However, if you prefer to use the previous presets, pplease skip this step.
Load factory default preset data

User preset data will be erased from the M7.


7. Mindray strongly recommends
backing up user presets before loading factory default.
Setup key on the keyboard [Manage Settings]  [Load Factory] (on the
Log in as Admin. Press Setup
bottom right)  Click on [Ok] in the dialog The operation will cover current data, are you sure you want
to continue?  Click on [Exit] after it finishes  Click on [Return] to go back to scanning mode.

-The EndMar 4, 2011

Page 15 of 15