Manual Version: 6PW102-20151120

BOM: 3123A0R5

H3C NSQ1TGS8EA0 LPU manual


1 Card view
Figure 1 NSQ1TGS8EA0 LPU

2 Specifications
The NSQ1TGS8EA0 provides 8 SFP+ ports on its front panel.
Figure 2 Front panel of the NSQ1TGS8EA0

(1) SFP+ port

(2) SFP+ port status LED

Table 1 LPU specifications


Item

Specification

Dimensions (H W D)

40 399 352 mm (1.57 15.71 13.86 in)

Power consumption

111 W to 140 W

Weight

3.43 kg (7.56 lb)

Hot swapping

Supported

Connector type

LC

Interfaces

Eight 10 Gbps SFP+ ports

Transmission speed

1/10 Gbps

Ambient temperature
Ambient relative humidity

Operating: 0C to 45C (32F to 113F)


Not operating: 40C to +70C (40F to +158F)
Operating: 10% to 95%, noncondensing
Not operating: 5% to 95%, noncondensing
i

Manual Version: 6PW102-20151120

BOM: 3123A0R5

Item

Specification

Compatible device model


and slot

M9006 gateway (slot 2 to slot 5)


M9010 gateway (slot 0 to slot 3 and slot 6 to slot 9)
M9014 gateway (slot 0 to slot 5 and slot 8 to slot 13)
T9006 IPS (slot 2 to slot 5)
T9010 IPS (slot 0 to slot 3 and slot 6 to slot 9)
T9014 IPS (slot 0 to slot 5 and slot 8 to slot 13)

Table 2 SFP+ module specifications


Optional SFP+
module

Central
wavelengt
h

Connector
type

Cable
specifications

50/125m MMF
SFP-XG-SX-MM8
50-A

850 nm

LC
62.5/125m
MMF

SFP-XG-LX220-M
M1310

62.5/125m
MMF
1310 nm

LC
50/125m MMF

Mode
bandwidth

Maximum
transmission
distance

2000MHz*km

300 m (984.26 ft.)

500MHz*km

82 m (269.03 ft)

400MHz*km

66 m (216.54 ft)

200MHz*km

33 m (108.27 ft)

160MHz*km

26 m (85.30 ft)

500MHz*km

220 m (721.78 ft)

500MHz*km

220 m (721.78 ft)

400MHz*km

100 m (328.08 ft)

SFP-XG-LX-SM13
10

1310 nm

LC

9/125m SMF

N/A

10 km (6.21 miles)

SFP-XG-LH40-SM
1550

1550 nm

LC

9/125m SMF

N/A

40 km (24.86 miles)

For supported SFP+ cables, see the following table.


Table 3 SFP+ cable specifications
Optional SFP+ Cable

Length

LSWM2STK

1.2 m (3.94 ft)

LSWM3STK

3 m (9.84 ft)

LSTM1STK

5 m (16.40 ft)

LSTM2STK

7 m (22.97 ft)

Data rate

Type

Remarks

10.31 Gbps

SFP+ cable

Dedicated to
interconnecting
SFP+ ports

For supported Gigabit SFP modules, see the following table.

ii

Manual Version: 6PW102-20151120

BOM: 3123A0R5

Table 4 Specifications of Gigabit SFP modules


Optional Gigabit SFP
module

Central
wavelength

Connector

Cable specifications

Maximum
transmission
distance

50/125 m multimode
fiber

550 m
(1804.46 ft)

62.5/125 m
multimode fiber

275 m (902.23
ft)

SFP-GE-SX-MM850-A

850 nm

LC

SFP-GE-LX-SM1310-A

1310 nm

LC

9/125 m single-mode
fiber

10 km (6.21
miles)

SFP-GE-LH40-SM1310

1310 nm

LC

9/125 m single-mode
fiber

40 km (24.86
miles)

SFP-GE-LH40-SM1550

1550 nm

LC

9/125 m single-mode
fiber

40 km (24.86
miles)

SFP-GE-LH70-SM1550

1550 nm

LC

9/125 m single-mode
fiber

70 km (43.49
miles)

SFP-GE-LH100-SM1550

1550 nm

LC

9/125 m single-mode
fiber

100 km (62.13
miles)

SFP-GE-T

N/A

RJ-45

Category-5 twisted pair

100 m (328.08
ft)

LC

9/125 m single-mode
fiber

10 km (6.21
miles)

LC

9/125 m single-mode
fiber

10 km (6.21
miles)

SFP-GE-LX-SM
1310-BIDI
SFP-GE-LX-SM
1490-BIDI

The two
modules
must be
used
together.

TX: 1310 nm
RX: 1490 nm
TX: 1490 nm
RX: 1310 nm

SFP-GE-LH70-SM1470-C
W

1470 nm

LC

9/125 m single-mode
fiber

70 km (43.49
miles)

SFP-GE-LH70-SM1490-C
W

1490 nm

LC

9/125 m single-mode
fiber

70 km (43.49
miles)

SFP-GE-LH70-SM1510-C
W

1510 nm

LC

9/125 m single-mode
fiber

70 km (43.49
miles)

SFP-GE-LH70-SM1530-C
W

1530 nm

LC

9/125 m single-mode
fiber

70 km (43.49
miles)

SFP-GE-LH70-SM1550-C
W

1550 nm

LC

9/125 m single-mode
fiber

70 km (43.49
miles)

SFP-GE-LH70-SM1570-C
W

1570 nm

LC

9/125 m single-mode
fiber

70 km (43.49
miles)

SFP-GE-LH70-SM1590-C
W

1590 nm

LC

9/125 m single-mode
fiber

70 km (43.49
miles)

SFP-GE-LH70-SM1610-C
W

1610 nm

LC

9/125 m single-mode
fiber

70 km (43.49
miles)

iii

Manual Version: 6PW102-20151120

BOM: 3123A0R5

NOTE:
BIDI modules use different central wavelengths in transmit and receive directions, in order to implement
bidirectional transmission of optical signals over the same fiber.
BIDI modules must be used in pair. For example, if an SFP-GE-LX-SM1310-BIDI is used at one end, an
SFP-GE-LX-SM1490-BIDI must be used at the other end.

3 LEDs
The NSQ1TGS8EA0 provides LEDs to show the operating status of the LPU.
Table 5 LED description
LED status

Description

Flashing yellow

The SFP+ port is receiving or sending data at 100/1000 Mbps.

Flashing green

The SFP+ port is receiving or sending data at 10 Gbps.

Steady yellow

A 100/1000 Mbps link is present.

Steady green

A 10 Gbps link is present.

Off

No link is present.

4 Installing and removing the NSQ1TGS8EA0


CAUTION:
Wear a well-grounded ESD-preventive wrist before you install or remove the LPU.
Do not touch the surface-mounted components directly with your hands when you install or remove the
LPU.

4.1 Installing the NSQ1TGS8EA0


1.

Face the front panel of the device.

2.

Identify the slot to install the LPU, and remove the filler panel from the slot.
This manual uses slot 3 as an example.

3.

Place the LPU horizontally with the surface-mounted components facing upward. Pull outward the
ejector levers and gently push the LPU in along the slot guide rails until the LPU is in close contact
with the backplane. (See callout 1 in Figure 3 .)

4.

Push the ejector levers inward. (See callout 2 in Figure 3 .)

5.

Tighten the captive screws with a Phillips screwdriver to secure the LPU in the slot. (See callout 3
in Figure 3 .)

iv

Manual Version: 6PW102-20151120

BOM: 3123A0R5

Figure 3 Installing an NSQ1TGS8EA0

(1) Gently push the LPU in along the slot guide rails until the LPU is in close contact with the backplane.
(2) Push the ejector levers inward.
(3) Tighten the captive screws with a Phillips screwdriver.

4.2 Removing the NSQ1TGS8EA0


1.

Use a Phillips screwdriver to loosen the captive screws at both sides of the LPU until all pressure is
released.

2.

Pull the ejector levers at both sides of the LPU outward, and pull the LPU along the guide rails until
it completely comes out of the backplane.

3.

Place the LPU on an anti-static workbench with the surface-mounted components up, or put it in an
anti-static bag.
If no new LPU is to be installed, install a filler panel to prevent dust and ensure good ventilation in
the device.

5 Obtaining documentation
Take the following steps to get the latest documentation from the H3C website at www.h3c.com:
1.

Go to http://www.h3c.com/portal/Technical_Documents, or click Technical Support &


Documents > Technical Documents on the top navigation bar at http://www.h3c.com.

2.

Choose the desired product category and model.

Copyright 2015 Hangzhou H3C Technologies Co., Ltd.