BOM: 3123A0R5
2 Specifications
The NSQ1TGS8EA0 provides 8 SFP+ ports on its front panel.
Figure 2 Front panel of the NSQ1TGS8EA0
Specification
Dimensions (H W D)
Power consumption
111 W to 140 W
Weight
Hot swapping
Supported
Connector type
LC
Interfaces
Transmission speed
1/10 Gbps
Ambient temperature
Ambient relative humidity
BOM: 3123A0R5
Item
Specification
Central
wavelengt
h
Connector
type
Cable
specifications
50/125m MMF
SFP-XG-SX-MM8
50-A
850 nm
LC
62.5/125m
MMF
SFP-XG-LX220-M
M1310
62.5/125m
MMF
1310 nm
LC
50/125m MMF
Mode
bandwidth
Maximum
transmission
distance
2000MHz*km
500MHz*km
82 m (269.03 ft)
400MHz*km
66 m (216.54 ft)
200MHz*km
33 m (108.27 ft)
160MHz*km
26 m (85.30 ft)
500MHz*km
500MHz*km
400MHz*km
SFP-XG-LX-SM13
10
1310 nm
LC
9/125m SMF
N/A
10 km (6.21 miles)
SFP-XG-LH40-SM
1550
1550 nm
LC
9/125m SMF
N/A
40 km (24.86 miles)
Length
LSWM2STK
LSWM3STK
3 m (9.84 ft)
LSTM1STK
5 m (16.40 ft)
LSTM2STK
7 m (22.97 ft)
Data rate
Type
Remarks
10.31 Gbps
SFP+ cable
Dedicated to
interconnecting
SFP+ ports
ii
BOM: 3123A0R5
Central
wavelength
Connector
Cable specifications
Maximum
transmission
distance
50/125 m multimode
fiber
550 m
(1804.46 ft)
62.5/125 m
multimode fiber
275 m (902.23
ft)
SFP-GE-SX-MM850-A
850 nm
LC
SFP-GE-LX-SM1310-A
1310 nm
LC
9/125 m single-mode
fiber
10 km (6.21
miles)
SFP-GE-LH40-SM1310
1310 nm
LC
9/125 m single-mode
fiber
40 km (24.86
miles)
SFP-GE-LH40-SM1550
1550 nm
LC
9/125 m single-mode
fiber
40 km (24.86
miles)
SFP-GE-LH70-SM1550
1550 nm
LC
9/125 m single-mode
fiber
70 km (43.49
miles)
SFP-GE-LH100-SM1550
1550 nm
LC
9/125 m single-mode
fiber
100 km (62.13
miles)
SFP-GE-T
N/A
RJ-45
100 m (328.08
ft)
LC
9/125 m single-mode
fiber
10 km (6.21
miles)
LC
9/125 m single-mode
fiber
10 km (6.21
miles)
SFP-GE-LX-SM
1310-BIDI
SFP-GE-LX-SM
1490-BIDI
The two
modules
must be
used
together.
TX: 1310 nm
RX: 1490 nm
TX: 1490 nm
RX: 1310 nm
SFP-GE-LH70-SM1470-C
W
1470 nm
LC
9/125 m single-mode
fiber
70 km (43.49
miles)
SFP-GE-LH70-SM1490-C
W
1490 nm
LC
9/125 m single-mode
fiber
70 km (43.49
miles)
SFP-GE-LH70-SM1510-C
W
1510 nm
LC
9/125 m single-mode
fiber
70 km (43.49
miles)
SFP-GE-LH70-SM1530-C
W
1530 nm
LC
9/125 m single-mode
fiber
70 km (43.49
miles)
SFP-GE-LH70-SM1550-C
W
1550 nm
LC
9/125 m single-mode
fiber
70 km (43.49
miles)
SFP-GE-LH70-SM1570-C
W
1570 nm
LC
9/125 m single-mode
fiber
70 km (43.49
miles)
SFP-GE-LH70-SM1590-C
W
1590 nm
LC
9/125 m single-mode
fiber
70 km (43.49
miles)
SFP-GE-LH70-SM1610-C
W
1610 nm
LC
9/125 m single-mode
fiber
70 km (43.49
miles)
iii
BOM: 3123A0R5
NOTE:
BIDI modules use different central wavelengths in transmit and receive directions, in order to implement
bidirectional transmission of optical signals over the same fiber.
BIDI modules must be used in pair. For example, if an SFP-GE-LX-SM1310-BIDI is used at one end, an
SFP-GE-LX-SM1490-BIDI must be used at the other end.
3 LEDs
The NSQ1TGS8EA0 provides LEDs to show the operating status of the LPU.
Table 5 LED description
LED status
Description
Flashing yellow
Flashing green
Steady yellow
Steady green
Off
No link is present.
2.
Identify the slot to install the LPU, and remove the filler panel from the slot.
This manual uses slot 3 as an example.
3.
Place the LPU horizontally with the surface-mounted components facing upward. Pull outward the
ejector levers and gently push the LPU in along the slot guide rails until the LPU is in close contact
with the backplane. (See callout 1 in Figure 3 .)
4.
5.
Tighten the captive screws with a Phillips screwdriver to secure the LPU in the slot. (See callout 3
in Figure 3 .)
iv
BOM: 3123A0R5
(1) Gently push the LPU in along the slot guide rails until the LPU is in close contact with the backplane.
(2) Push the ejector levers inward.
(3) Tighten the captive screws with a Phillips screwdriver.
Use a Phillips screwdriver to loosen the captive screws at both sides of the LPU until all pressure is
released.
2.
Pull the ejector levers at both sides of the LPU outward, and pull the LPU along the guide rails until
it completely comes out of the backplane.
3.
Place the LPU on an anti-static workbench with the surface-mounted components up, or put it in an
anti-static bag.
If no new LPU is to be installed, install a filler panel to prevent dust and ensure good ventilation in
the device.