TROUBLESHOOTING OF

ELECTRICAL SYSTEM (E-MODE)

INFORMATION CONTAINED IN TROUBLESHOOTING TABLE ............................................................... 20-502


BEFORE CARRYING OUT TROUBLESHOOTING OF E MODE ........................................................... 20-502-1
E-1 Engine does not start (Engine does not rotate) ................................................................................ 20-503
E-2 Engine stops while in operation ........................................................................................................ 20-507
E-3 Engine speed is irregular, or there is hunting ................................................................................... 20-508
E-4 Engine does not stop ........................................................................................................................ 20-510
E-5 Auto-decelerator does not work ........................................................................................................ 20-512
E-6 Auto engine warm-up device does not work ..................................................................................... 20-513
E-7 Preheater does not work................................................................................................................... 20-514
E-8 All work equipment, swing and travel do not move........................................................................... 20-516
E-9 One-touch power maximizing function does not work ...................................................................... 20-518
E-10 No display in monitor panel at all ...................................................................................................... 20-519
E-11 Part of display on monitor panel is missing....................................................................................... 20-520
E-12 Monitor panel displays contents irrelevant to the model ................................................................... 20-520
E-13 Fuel level monitor red lamp lights up while engine is running........................................................... 20-521
E-14 Engine coolant temperature gauge does not indicate correctly ........................................................ 20-522
E-15 Hydraulic oil temperature gauge does not display correctly ............................................................. 20-523
E-16 Fuel gauge does not display correctly .............................................................................................. 20-524
E-17 Swing lock monitor does not display correctly .................................................................................. 20-526
E-18 When the monitor switch is operated, no display appears ............................................................... 20-528
E-19 Windshield wiper does not work ....................................................................................................... 20-530
E-20 Alarming buzzer cannot be cancelled ............................................................................................... 20-532
E-21 "Boom RAISE" is not correctly displayed in monitor function ........................................................... 20-533
E-22 "Boom LOWER" is not correctly displayed in monitor function ......................................................... 20-534
E-23 "Arm DIGGING" is not correctly displayed in monitor function ......................................................... 20-535
E-24 "Arm DUMPING" is not correctly displayed in monitor function ........................................................ 20-536
E-25 "Bucket DIGGING" is not correctly displayed in monitor function ..................................................... 20-537
E-26 "Bucket DUMPING" is not correctly displayed in monitor function.................................................... 20-538
E-27 "SWING" is not correctly displayed in monitor function .................................................................... 20-540
E-28 "TRAVEL" is not correctly displayed in monitor function................................................................... 20-542
E-29 "Travel Differential Pressure" is not correctly displayed in monitor function ..................................... 20-544
E-30 "Service" is not correctly displayed in monitor function..................................................................... 20-546
E-31 Troubleshooting for air conditioner system ....................................................................................... 20-548
E-32 Travel alarm does not sound ............................................................................................................ 20-560

PC200/220(LC)-7

20-501
(11)

TROUBLESHOOTING

INFORMATION CONTAINED IN TROUBLESHOOTING TABLE

INFORMATION CONTAINED IN TROUBLESHOOTING TABLE


a The following information are edited and contained in the "Information Contained in Troubleshooting Table".
You are required to proceed with troubleshooting after fully grasping the contents.
Failure
information

Phenomena occurring on machine

Relative
information

Information on occurred failures and troubleshooting


Cause

<Contents>
The standard values in normalcy by which to judge "good" or "no good" about presumed causes.
References for making judgement of "good" or "no good"

Presumed cause and standard value in normalcy

Standard value in normalcy and references for troubleshooting

Cause for presumed


failure
(The attached No. for
filing and reference
purpose only. It does not
stand for any priority)

<Phenomena of wiring harness fault>


Failure due to disconnection
Defective contact with connector or disconnection of wiring harness has occurred.
Grounding fault
A wiring harness that is not originally connected with a grounding circuit is in contact
with it.
Failure due to short-circuiting
A wiring harness that is not originally connected with a power source circuit (24 V) is
in contact with it.
<Points to remember in troubleshooting>
1) Connector denotation method and handling of T-adapters
Insert or connect T-adapters in the following manner, unless specifically otherwise
instructed.
If there is no indication of (male) or (female) in the connector No., pull off a connector and insert a T-adapter into both sides of male and female.
If there is an indication of (male9 and (female) in the connection No., pull off a connector and insert a T-adapter into only one side of (male) or (female).
2) Description sequence of pin No. and handling of circuit tester leads
Connect the positive lead (+) and negative lead () for troubleshooting in the following manner unless specifically otherwise instructed.
Connect the positive lead (+) to a pin No. marked at the front or wiring harness.
Connect the negative lead () to a pin No. marked at the rear or wiring harness.

Relative Electrical Circuit Diagram

This is part of the electrical circuit diagram which shows the portion where the failure occurred.
Connector No.: Indicates (Type - numbers of a pin) (color)
Arrow: Roughly indicates the location in the machine where it is installed.

20-502
(1)

PC200/220(LC)-7

TROUBLESHOOTING

BEFORE CARRYING OUT TROUBLESHOOTING OF E MODE

BEFORE CARRYING OUT TROUBLESHOOTING OF E MODE


Connection table of fuse box
a This connection table shows the devices to which each power supply of the fuse box supplies power directly
(A switch power supply is a device which supplies power while the starting switch is at the ON position and
a constant power supply is a device which supplies power while the starting switch is at the OFF position).
a When carrying out troubleshooting for an electric system, check its fuse box and fusible link to see if the power is supplied normally.
Type of power
supply

Fuse No.

Fuse capacity

Destination of power
Governor, pump controller (Controller power supply)

10A

Emergency pump drive resistor


Swing holding brake release switch

Switch power
supply (Fusible
link: A34)

Switch power
supply (Fusible
link: A34)

Switch power
supply (Fusible
link: A34)

Constant power
supply (Fusible
link: A35)

PC200/220(LC)-7

Governor, pump controller (Solenoid power supply)

20A

10A

10A

10A

Horn switch

10A

(Spare)

10A

10A

10A

10

10A

(Spare)

11

20A

Air conditioner unit

12

20A

13

20A

Light switch

14

10A

Service power supply (M32 connector)

15

10A

16

10A

17

20A

Monitor panel

18

10A

Starting switch

19

10A

Room lamp

20

10A

(Spare)

Attachment return switching relay (Coil side and contact side)


Lock switch
Cigarette lighter
Windshield washer motor

Rotary lamp switch


Additional relay (Coil side and contact side)
Light relay (Contact side)
One-touch power maximizing switch
Radio

Starting motor cut-out (Personal code) relay (Coil side)


Monitor panel

Travel alarm
DC/DC converter
Radio
Air conditioner unit

20-502-1
(11)

TROUBLESHOOTING

E-1

E-1 Engine does not start (Engine does not rotate)


Failure
information

The engine does not start (the engine does not rotate).

Relative
information

The following two engine start locking mechanisms are provided in the engine starting circuit.
1) Engine start locking by means of password in the monitor panel
2) Engine start locking by means of lock lever

Presumed cause and standard value in normalcy

Cause
1

Shortage in battery
capacity

Fuse Nos. 3 and 18


and Fusible Link A35
fault

Engine starting
switch fault
(Internal
disconnection)

Lock switch fault


(Internal
short-circuiting)

Engine starting
motor cut relay, R11
and R13 defective
(Internal
disconnection or
short-circuiting)

Standard value in normalcy and references for troubleshooting


Battery voltage

Battery electrolyte specific gravity

Min. 24 V

Min. 1.26

When a fuse or fusible link is blown, there is a big possibility that grounding fault occurred in
the circuit. (Refer to cause 10)
If a monitor lamp does not light up in the monitor panel, check the power source circuit
between the battery and the specific fuse.
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.
H15 (male)

Position

Resistance value

OFF

Min. 1 Mz

Start

Max. 1 z

Between (1) and (4)

a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.
S14 (female)
Between (1) and (3)

Lock lever

Resistance value

Release

Min. 1 Mz

LOCK

Max. 1 z

a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.
R11 (female) & R13 (male)

Resistance value

Between (1) and (2)

100 500 z

Between (3) and (5)

Min. 1 Mz

Between (3) and (6)

Max. 1 z

a Turn the engine starting switch OFF for the preparations, and keep the engine running
during the troubleshooting. (If all of the power source, grounding (GND), generation signal
and engine start input are normal and yet the engine start output is not normal, the engine
starting motor relay is defective)

Engine starting
motor fault
(Internal
disconnection or
short-circuiting)

Engine starting
motor fault
(Internal disconnection or damage)

Safety relay

Voltage

Power source: Between B terminal and grounding

20 30 V

GND (grounding): Between E terminal and grounding

Connected

Generation signal: Between R terminal (A27 (2)) and


grounding

Start

Max. 1 V

Engine start input: Between S terminal (A27 (1)) and


grounding

20 30 V

Engine start output: Between C terminal and grounding

20 30 V

a Turn the engine starting switch OFF for the preparations, and keep the engine running
during the troubleshooting. (If all of the power source, grounding (GND), generation signal
and engine start input are normal and yet the engine start output is not normal, the engine
starting motor relay is defective)
Engine starting motor
Power source: B terminal and grounding
Engine start input: C terminal and grounding

PC200/220(LC)-7

Engine starting switch

Engine startVoltage
ing switch
Start

20 30 V
20 30 V

20-503
(11)

TROUBLESHOOTING

Cause

Alternator fault
(Internal
short-circuit)

E-1

Standard value in normalcy and references for troubleshooting


a Turn the engine starting switch OFF for the preparations, and hold it in the ON position or
running during the troubleshooting.
E12 (male)

Voltage

Between (1) and grounding

Max. 1 V

a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.

Presumed cause and standard value in normalcy

Disconnection of wiring harness


(Disconnection or
defective contact
with connector)

Wiring harness between FB1-18 outlet and H15 (female) (1)

Resistance
value

Max. 1 z

Wiring harness from H15 (female) (4) to J01 to R11 (female)


(5)

Resistance
value

Max. 1 z

Wiring harness between R11 (female) (3) and A27 (female) (1)

Resistance
value

Max. 1 z

Wiring harness between engine starting motor relay C terminal and engine starting motor C terminal

Resistance
value

Max. 1 z

Wiring harness between FB1-3 and S14 (female) (1)

Resistance
value

Max. 1 z

Wiring harness between S14 (female) (3) and R11 (female) (1)

Resistance
value

Max. 1 z

Wiring harness between R11 (female) (2) and R13 (female) (6)

Resistance
value

Max. 1 z

Wiring harness from R13 (female) (3) to J04 to grounding

Resistance
value

Max. 1 z

a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.

Grounding fault of
wiring harness
10
(Contact with
grounding circuit)

Short-circuiting of
wiring harness
11
(Contact with 24 V
circuit)

20-504
(1)

Between wiring harness from battery relay B terminal (A23)


to A35 to FB1-18 and grounding

Resistance
value

Min. 1 Mz

Between wiring harness between FB1-18 outlet and H15


(female) (1) and grounding

Resistance
value

Min. 1 Mz

Between wiring harness from H15 (female) (4) to J01 to R11


(female) (5) and grounding

Resistance
value

Min. 1 Mz

Between wiring harness between R11 (female) (3) and A27


(female) (1) and grounding

Resistance
value

Min. 1 Mz

Between wiring harness between engine starting motor relay C


terminal and engine starting motor C terminal and grounding

Resistance
value

Min. 1 Mz

Between wiring harness between FB1-3 and S14 (female) (1)


and grounding

Resistance
value

Min. 1 Mz

Between wiring harness between S14 (female) (3) and R11


(female) (1) and grounding

Resistance
value

Min. 1 Mz

Between wiring harness from R13 (female) (2) to J05 to P02


(female) (14) and grounding

Resistance
value

Min. 1 Mz

a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.
Wiring harness between A27 (female) (2) and E12 (female)
(1), or wiring harness from A27 (female) (2) to J02 to D01
(female) (6), or between wiring harness between A27
(female) (2) and P02 (female) (11) and grounding

Voltage

Max. 1 V

PC200/220(LC)-7

TROUBLESHOOTING

E-1

Electrical Circuit Diagram for Engine Start, Stop and Battery Charging
PC200, 200LC-7 Serial No. 200001 250000
PC220, 220LC-7 Serial No. 60001 65000

PC200/220(LC)-7

20-505
(7)

TROUBLESHOOTING

E-1

Electrical Circuit Diagram for Engine Start, Stop and Battery Charging
PC200, 200LC-7 Serial No. 250001 and up
PC220, 220LC-7 Serial No. 65001 and up

20-506
(7)

PC200/220(LC)-7

TROUBLESHOOTING

E-2

E-2 Engine stops while in operation


Failure
information

The engine suddenly stopped while in operation.

Relative
information

Input from the governor potentiometer (voltage) can be confirmed in the monitor function.
(Code No. 031: governor potentiometer voltage)
Cause

Standard value in normalcy and references for troubleshooting

Presumed cause and standard value in normalcy

a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.
1

Governor potentiometer fault


(Internal failure)

E06 (male)

Resistance value

Between (A) and (C)

4.0 6.0 kz

Between (B) and (A)

0.25 5.0 kz

Between (B) and (C)

0.25 5.0 kz

Disconnection of wir- a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
ing harness
during the troubleshooting.
(Disconnection or
Wiring harness between C01 (female) (13) and E10 (female)
Resistance
defective contact
Max. 1 z
(B)
value
with connector)

Grounding fault of
wiring harness
(Contact with
grounding circuit)

a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.
Between wiring harness between C01 (female) (13) and E10
(female) (B) and grounding

Resistance
value

Min. 1 Mz

a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.
4

Governor pump
controller defective

C01

Voltage

Between (22) and (21)

4.5 5.5 V

Between (13) and (21)

0.5 4.5 V

Electrical Circuit Diagram for Fuel Dial

PC200/220(LC)-7

20-507
(5)

TROUBLESHOOTING

E-3

E-3 Engine speed is irregular, or there is hunting


Failure
information

Engine speed is irregular at low idle.


There is hunting.
Engine speed is lower than specified at high idle.

Relative
information

Engine rotation can be confirmed in the monitor function.


(Code No. 010: Engine rotation)
Cause

Presumed cause and standard value in normalcy

Model code signal


fault
(Internal failure)

Standard value in normalcy and references for troubleshooting


If the monitor display is not normal, proceed to Service Code [E217].
Monitoring Code

Item

Normal display

002
003

Controller model code

200

Governor lever
improperly adjusted

Refer to the section "Special Function of Monitor Panel" in this manual.

Governor motor
improperly working

If the governor motor lever moves smoothly in the following operations, it is judged as normal.
The fuel dial is operated between low idle and high idle.
The engine is stopped with the fuel dial.

Engine fuel control


system defective

Refer to the Engine Shop Manual.

Disconnection of wir- a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
ing harness
during the troubleshooting.
(Disconnection or
Wiring harness from C01 (female) (23) to J07 to H15 (female)
Resistance
defective contact
Max. 1 z
(5)
value
with connector)

Grounding fault of
wiring harness
(Contact with
grounding circuit)

a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.

Governor pump
controller defective

As this is an internal failure, troubleshooting cannot be conducted.


(If there is none of the causes from Item 1 to 6 above, the controller is judged as defective)

20-508
(11)

Between wiring harness between C01 (female) (23) to J17


and H15 (female) (5) and grounding

Resistance
value

Min. 1 Mz

PC200/220(LC)-7

TROUBLESHOOTING

E-3

Electrical Circuit Diagram for Engine Start and Stop and Battery Charging
PC200, 200LC-7 Serial No. 200001 250000
PC220, 220LC-7 Serial No. 60001 65000

PC200/220(LC)-7

20-509
(7)

TROUBLESHOOTING

E-3

Electrical Circuit Diagram for Engine Start and Stop and Battery Charging
PC200, 200LC-7 Serial No. 250001 and up
PC220, 220LC-7 Serial No. 65001 and up

20-509-1
(7)

PC200/220(LC)-7

TROUBLESHOOTING

E-4

E-4 Engine does not stop


The engine does not stop.

Relative
information

The Governor pump controller drives the battery relay for the min. 4 seconds and max. 7 seconds from
the moment the engine starting switch is turned OFF to the moment the engine completely stops.
It can be confirmed in the monitor function how the battery relay works (ON or OFF)
(Code No. 037: Controller output)

Presumed cause and standard value in normalcy

Failure
information

Cause

Standard value in normalcy and references for troubleshooting

Battery relay fault

If operating sound is heard from the battery relay contact, when turning the engine starting
switch, the battery relay is judged as normal.
Starting switch OFFoONoOFF

Assembled-type
diode D01 fault
(Internal disconnection)

a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.
D01 (male)

Digital type circuit tester

Continuity

Between (5) and (1)

Diode mode

Continued

a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.

Disconnection of wiring harness


(Disconnection or
defective contact
with connector)

Governor pump
controller defective

20-510
(5)

Wiring harness between C03 (female) (4) and D01 (female)


(5)

Resistance
value

Max. 1 z

Wiring harness from D01 (female) (1) to J01 to battery relay


BR terminal (A21)

Resistance
value

Max. 1 z

Wiring harness between battery relay E terminal (A20) and


grounding

Resistance
value

Max. 1 z

a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.
C03

Engine starting switch

Voltage

Between (4) and grounding

ONoOFF

20 30 V
(for 4 to 7 seconds)

PC200/220(LC)-7

TROUBLESHOOTING

E-4

Electrical Circuit Diagram for Engine Start and Stop and Battery Charging
PC200, 200LC-7 Serial No. 200001 250000
PC220, 220LC-7 Serial No. 60001 65000

PC200/220(LC)-7

20-511
(5)

TROUBLESHOOTING

E-4

Electrical Circuit Diagram for Engine Start and Stop and Battery Charging
PC200, 200LC-7 Serial No. 250001 and up
PC220, 220LC-7 Serial No. 65001 and up

20-511-1
(7)

PC200/220(LC)-7

TROUBLESHOOTING

E-5

E-5 Auto-decelerator does not work


Failure
information

The auto-decelerator does not work.

Relative
information

Rotation of the auto-decelerator is set at 1,400 rpm. If the fuel dial is not set adjusting to this level, the
auto-decelerator does not work.
Confirm the display on the monitor panel, when the engine is running.
Cause

Boom RAISE signal


fault

Standard value in normalcy and references for troubleshooting


Monitoring code

Item

Normal display

019

Boom RAISE

Lever operation: ON
Lever NEUTRAL: OFF

If the display on the monitor panel is not normal, proceed to No. E-21 Troubleshooting.

Boom LOWER signal fault

Monitoring code

Item

Normal display

019

Boom LOWER

Lever operation: ON
Lever NEUTRAL: OFF

If the display on the monitor panel is not normal, proceed to No. E-22 Troubleshooting.

Presumed cause and standard value in normalcy

Arm DIGGING signal


fault

Monitoring code

Item

Normal display

019

Arm DIGGING

Lever operation: ON
Lever NEUTRAL: OFF

If the display on the monitor panel is not normal, proceed to No. E-23 Troubleshooting.

Arm DUMPING
signal fault

Monitoring code

Item

Normal display

019

Arm DUMPING

Lever operation: ON
Lever NEUTRAL: OFF

If the display on the monitor panel is not normal, proceed to No. E-24 Troubleshooting.

Bucket DIGGING
signal fault

Monitoring code

Item

Normal display

021

Bucket DIGGING

Lever operation: ON
Lever NEUTRAL: OFF

If the display on the monitor panel is not normal, proceed to No. E-25 Troubleshooting.

Bucket DUMPING
signal fault

Monitoring code

Item

Normal display

021

Bucket DUMPING

Lever operation: ON
Lever NEUTRAL: OFF

If the display on the monitor panel is not normal, proceed to No. E-26 Troubleshooting.

Swing signal fault

Monitoring code

Item

Normal display

019

Swing

Lever operation: ON
Lever NEUTRAL: OFF

If the display on the monitor panel is not normal, proceed to No. E-27 Troubleshooting.

Travel signal fault

Monitoring code

Item

Normal display

019

Travel

Lever operation: ON
Lever NEUTRAL: OFF

If the display on the monitor panel is not normal, proceed to No. E-28 Troubleshooting.

Attachment signal
fault

Monitoring code

Item

Normal display

021

Service

Lever operation: ON
Lever NEUTRAL: OFF

If the display on the monitor panel is not normal, proceed to No. E-30 Troubleshooting.
Governor pump
10
controller defective

20-512
(5)

As this is an internal failure, troubleshooting cannot be conducted. (If there is none of the
causes listed in Item 1 through 9, the controller is judged as defective.

PC200/220(LC)-7

TROUBLESHOOTING

E-6

E-6 Auto engine warm-up device does not work


The auto engine warm-up device does not work.

Relative
information

The auto engine warm-up device is activated, when the engine coolant temperature is below 30C, and
raise the engine rotation up to 1,200 rpm.
The auto engine warm-up device is released by keeping the fuel dial opening at above 70% for more
than 3 seconds, when the engine starting switch is in the ON position or after the engine is started.

Presumed cause and standard


value in normalcy

Failure
information

Cause

Engine coolant
temperature signal
fault

Governor pump
controller defective

PC200/220(LC)-7

Standard value in normalcy and references for troubleshooting


If the display on the monitor panel is not normal, proceed to No. E-14
Troubleshooting.
Monitoring code
041

Item

Normal display

Engine coolant
temperature

Compare with the actual


engine coolant
temperature.

As this is an internal failure, troubleshooting cannot be conducted.


(If the fault mentioned in the above item is not found, the Governor pump controller is
judged as defective)

20-513
(11)

TROUBLESHOOTING

E-7

E-7 Preheater does not work


Failure
information (1)

Even if the preheater switch is turned to the PREHEAT position, the preheating monitor lamp does not
light up.

Relative
information

Input of the preheating signal (ON or OFF) can be confirmed in the monitor function.
(Code No. 045: Monitor input 1)

Presumed cause and standard


value in normalcy

Cause

Standard value in normalcy and references for troubleshooting

Engine starting
switch fault

If preheating does not occur (the heater is not warmed up), refer to Failure Phenomenon (2) below.

Disconnection of wir- a Turn the engine starting switch OFF for the preparations, and hold it in the OFF posiing harness
tion during the troubleshooting.
(Disconnection or
Resistance
defective contact
Max. 1 z
Wiring harness between P02 (female)
and J02
value
with connector)
a Turn the engine starting switch OFF for the preparations.

P02

Monitor panel fault


Between

Engine starting switch

Voltage

OFF

Max. 1 V

HEAT

20 30 V

and grounding

Failure
information (2)

Even if the preheater switch is turned to the PREHEAT position, the preheater does not become warm.

Relative
information

In low coolant temperature (lower than 30C), the governor pump controller drives the heater relay for
100 seconds after the engine is started and automatically warms up the engine.
Cause

Presumed cause and standard


value in normalcy

20-514
(11)

Engine starting
switch fault
(Internal disconnection)

Heater relay fault


(Internal disconnection)
Electrical intake air
heater
(Internal disconnection)

Standard value in normalcy and references for troubleshooting


a Turn the engine starting switch OFF for the preparations.
H15 (male)
Between

Engine starting switch

Resistance value

OFF

Min. 1 Mz

HEAT

Max. 1 z

and

a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Heater relay

Continuity and resistance value

Between coil terminal and grounding

Continued

Between contact terminals

Min. 1 Mz

a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Between heater terminals

Normal if continuity is established.

a Turn the engine starting switch OFF for the preparations, and hold it in the OFF posiDisconnection of wirtion during the troubleshooting.
ing harness
Resistance
Wiring harness from H15 (female)
to J02 to heater
(Disconnection or
Max. 1 z
value
relay terminal (A25)
defective contact
Wiring harness between battery relay M terminal (A22)
Resistance
with connector)
Max. 1 z
and heater relay terminal
value

PC200/220(LC)-7

TROUBLESHOOTING

E-7

Electrical Circuit Diagram for Engine Preheater

PC200/220(LC)-7

20-515
(1)

TROUBLESHOOTING

E-8

E-8 All work equipment, swing and travel do not move


Failure
information

All the work equipment, swing and travel do not move.

Relative
information

Cause

Presumed cause and standard value in normalcy

Fuse No. 3 fault

Switch lock defective


(Internal disconnection)

PPC lock solenoid


fault
(Internal disconnection or short-circuiting)
Assembled-type
diode D01 fault
(Internal short-circuiting)

Standard value in normalcy and references for troubleshooting


If the fuse is blown, there is a big possibility that grounding fault occurred in the circuit.
(Refer to cause 6)
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.
S14 (female)
Between (1) and (2)

Lock lever

Resistance value

Lock

Min. 1 Mz

Release

Max. 1 z

a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.
V01 (male)

Resistance value

Between (1) and (2)

20 60 z

Between (1) and grounding

Min. 1 Mz

a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.
D01 (male)

Resistance value

Between (8) and (4)

Min. 1 Mz

a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.

Disconnection of wirWiring harness between FB1-3 outlet and S14 (male) (1)
ing harness
(Disconnection or
defective contact
Wiring harness from S14 (male) (2) to J02 to V01 (female) (1)
with connector)
Wiring harness between V01 (female) (2) and grounding

Grounding fault of
wiring harness
(Contact with
grounding (GND)
circuit)

20-516
(11)

Resistance
value

Max. 1 z

Resistance
value

Max. 1 z

Resistance
value

Max. 1 z

a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.
Between wiring harness between FB1-3 outlet and S14
(male) (1) and grounding

Resistance
value

Min. 1 Mz

Wiring harness from S14 (male) (2) to J02 to V01 (female)


(1), or between wiring harness between S14 (male) (2) and
D01 (female) (8) and grounding

Resistance
value

Min. 1 Mz

PC200/220(LC)-7

TROUBLESHOOTING

E-8

Electrical Circuit Diagram for PPC Lock Solenoid

PC200/220(LC)-7

20-517
(11)

TROUBLESHOOTING

E-9

E-9 One-touch power maximizing function does not work


Failure
information

The one-touch power maximizing function does not work.

Relative
information

If the knob switch is pressed while the engine is running, the symbol mark is displayed in the monitor
panel.
Input from the knob switch can be confirmed in the monitor function. (Code No. 022: Switch input 1)

Presumed cause and standard value in normalcy

Cause
1

Fuse No. 9 fault

One-touch power
max. switch fault
(Internal disconnection)

Standard value in normalcy and references for troubleshooting


If the fuse is blown, there is a big possibility that grounding fault occurred in the circuit.
(Refer to cause 4)
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.
M23 (male)
Between (1) and (2)

Knob switch

Resistance value

Release

Min. 1 Mz

Depress

Max. 1 z

a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
Disconnection of wirduring the troubleshooting.
ing harness
Resistance
(Disconnection or
Wiring harness between FB1-9 outlet and M23 (female) (1)
Max. 1 z
value
defective contact
Wiring harness between M23 (female) (2) and C01 (female)
Resistance
with connector)
Max. 1 z
(11)
value

Grounding fault of
wiring harness
(Contact with
grounding (GND)
circuit)

a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.
Between wiring harness between FB1-9 outlet and M23
(female) (1) and grounding

Resistance
value

Min. 1 Mz

Between wiring harness between M23 (female) (2) and C01


(female) (11) and grounding

Resistance
value

Min. 1 Mz

a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.
5

Governor pump
controller defective

C01
Between (11) and grounding

Knob switch

Voltage

Release

Max. 1 V

Depress

20 30 V

Electric Circuit Diagram for One-Touch Power Maximizing Function

20-518
(11)

PC200/220(LC)-7

TROUBLESHOOTING

E-10

E-10 No display in monitor panel at all


Failure
information

When the engine starting switch is turned ON, there appears no display at all in the monitor panel.

Relative
information

Presumed cause and standard value in normalcy

Cause

Standard value in normalcy and references for troubleshooting


If the fuse is blown, there is a big possibility that grounding fault occurred in the circuit.
(Refer to cause 3)

Fuse No. 12 fault

a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
Disconnection of wirduring the troubleshooting.
ing harness
Resistance
(Disconnection or
Wiring harness from P01 (female) (1) (2) to J07 to FB1-12
Max. 1 z
value
defect contact with
Resistance
connector)
Wiring harness between P01 (female) (6) (7) and grounding
Max. 1 z
value

Grounding fault of
wiring harness
(Contact with
grounding (GND)
circuit)

a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.
Between wiring harness from P01 (female) (1) (2) to J07 to
FB1-12 outlet and grounding

Resistance
value

Min. 1 Mz

a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.
4

Monitor panel
defective

P01 (female)

Voltage and resistance value

Between (1) (2) and grounding

Voltage: 20 30 V

Between (6) (7) and grounding

Resistance value: Max. 1 z

Electrical Circuit Diagram for Power Source in Monitor Panel

PC200/220(LC)-7

20-519
(5)

TROUBLESHOOTING

E-11, E-12

E-11 Part of display on monitor panel is missing


Part of the display in the monitor panel is missing.

Relative
information

Presumed cause and


standard value in normalcy

Failure
information

Cause

Standard value in normalcy and references for troubleshooting

Monitor panel LCD


fault

If all the LCD in the monitor panel light up (i.e. the screen becomes totally white) by the
following switching operation, then the monitor panel is normal.
Switching operation: [ ] + [ A ] (simultaneous switching operation)

Monitor panel
defective

As this is an internal failure, troubleshooting cannot be conducted. (If there is no problem with the above switching operation, the monitor panel is judged as defective)

E-12 Monitor panel displays contents irrelevant to the model


The monitor panels displays contents that have nothing to do with the model on which it is installed.

Relative
information

Presumed cause and


standard value in normalcy

Failure
information

Cause

20-520
(1)

Model code signal


fault
(Internal failure)
Monitor panel
defective

Standard value in normalcy and references for troubleshooting


If the display on the monitor panel is normal, proceed to Service Code [E217].
Monitoring code

Item

Normal display

002
003

Controller model code

200

As this is an internal failure, troubleshooting cannot be conducted. (If there is no problem with the above switching operation, the monitor panel is judged as defective)

PC200/220(LC)-7

TROUBLESHOOTING

E-13

E-13 Fuel level monitor red lamp lights up while engine is running
Failure
information

The fuel level monitor red lamp lighted up while the engine was running.

Relative
information

If the fuel gauge shows in a red range on the monitor panel, the fuel level monitor lamp lights up red.
(5) Input signal from the fuel level sensor (voltage) can be confirmed in the monitor function.
(Code No. 042: Fuel level sensor)

Presumed cause and standard value in normalcy

Cause
1

Fuel level lowered


(system in normal
condition)

Fuel level sensor


fault
(Internal
disconnection)

Grounding fault of
wiring harness
(Contact with
grounding (GND)
circuit)

Standard value in normalcy and references for troubleshooting


a Refill fuel.
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.
A60 (male)
Between (1) and grounding

Fuel level

Resistance value

FULL (Upper limit)

Approx. 12 z

EMPTY (Lower limit)

85 110 z

a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.
Wiring harness between P02 (female) (2) and A60 (female)
(1)

Resistance
value

Max. 1 z

a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.
4

Monitor panel
defective

P02 (female)
Between (2) and grounding

Fuel level

Resistance value

FULL (Upper limit)

Approx. 12 z

EMPTY (Lower limit)

85 110 z

Electrical Circuit Diagram for Fuel Level Sensor

PC200/220(LC)-7

20-521
(5)

TROUBLESHOOTING

E-14

E-14 Engine coolant temperature gauge does not indicate correctly


Failure
information

The engine coolant temperature rises normally, but the display does not exceed the white range (C).
The engine coolant temperature remains stable, but the display rises to the red range (H).

Relative
information

Input from the engine coolant temperature sensor can be confirmed in the monitor function.
(Code No. 041: Engine coolant temperature)
Cause

Presumed cause and standard value in normalcy

Engine coolant temperature sensor fault


(Internal disconnection or short-circuiting)

Standard value in normalcy and references for troubleshooting


a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.
E05
Between (1) and (2)
Between (2) and grounding

Engine coolant
temperature
10 100 C

Resistance value
90 3.5 kz
Min. 1 Mz

a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
Disconnection of wirduring the troubleshooting.
ing harness
Resistance
(Disconnection or
Wiring harness between P02 (female) (1) and E05 (female) (2)
Max. 1 z
value
defective contact
Wiring harness between P02 (female) (13) and E05 (female)
Resistance
with connector)
Max. 1 z
(1)
value
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.

Grounding fault of
wiring harness
(Contact with
grounding (GND)
circuit)
Short-circuiting of
wiring harness
(Contact with 24 V
circuit)

a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.

Between wiring harness between P02 (female) (1) and E05


(female) (2) and grounding

Between wiring harness between P02 (female) (1) and E05


(female) (2) and grounding

Resistance
value

Voltage

Min. 1 Mz

Max. 1 V

a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.
5

Monitor panel
defective

P02
Between (1) and (13)
Between (1) and grounding

Engine coolant
temperature
10 100 C

Resistance value
90 3.5 kz
Min. 1 Mz

Electrical Circuit Diagram for Engine Coolant Temperature Sensor

20-522
(11)

PC200/220(LC)-7

TROUBLESHOOTING

E-15

E-15 Hydraulic oil temperature gauge does not display correctly


(Multi-monitor only)
Failure
information

Hydraulic oil temperature rises normally, but the display does not exceed the white range (C).
Hydraulic oil temperature remains stable, but the display rises up the red range (H).

Relative
information

Input from the hydraulic oil temperature sensor can be confirmed in the monitor function.
(Code No. 044: Hydraulic oil temperature)
Cause

Presumed cause and standard value in normalcy

Hydraulic oil temperature sensor fault


(Internal disconnection or short-circuiting)

Standard value in normalcy and references for troubleshooting


a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.
A61
Between (1) and (2)
Between (2) and grounding

Hydraulic oil
temperature
10 100 C

Resistance value
90 3.5 kz
Min. 1 Mz

a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
Disconnection of wirduring the troubleshooting.
ing harness
Wiring harness between P02 (female) (12) and A61 (female)
Resistance
(Disconnection or
Max. 1 z
(2)
value
defective contact
Wiring harness between P02 (female) (13) and A61 (female)
Resistance
with connector)
Max. 1 z
(1)
value
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.

Grounding fault of
wiring harness
(Contact with
grounding (GND)
circuit)
Short-circuiting of
wiring harness
(Contact with 24 V
circuit)

a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.

Between wiring harness between P02 (female) (12) and A61


(female) (2) and grounding

Between wiring harness between P02 (female) (12) and A61


(female) (2) and grounding

Resistance
value

Voltage

Min. 1 Mz

Max. 1 V

a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.
5

Monitor panel
defective

P02
Between (12) and (13)
Between (12) and grounding

Hydraulic oil
temperature
10 100 C

Resistance value
90 3.5 kz
Min. 1 Mz

Electrical Circuit Diagram for Hydraulic Oil Temperature Sensor

PC200/220(LC)-7

20-523
(11)

TROUBLESHOOTING

E-16

E-16 Fuel gauge does not display correctly


Failure
information

Though fuel was refilled, the display does not exceed the red range (E).
Though the remaining fuel level is low, the display does not drop below the green range (F).

Relative
information

Input from the fuel level sensor (voltage) can be confirmed in the monitor function.
(Code No. 042: Fuel sensor voltage)
Cause

Presumed cause and standard value in normalcy

Fuel level sensor


fault
(Internal disconnection or short-circuiting)

Standard value in normalcy and references for troubleshooting


a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.
A60 (male)
Between (1) and grounding

Fuel level

Resistance value

FULL (Upper limit)

Approx. 12 z

EMPTY (Lower limit)

85 110 z

Disconnection of wir- a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
ing harness
during the troubleshooting.
(Disconnection or
Resistance
defective contact
Wiring harness between P02 (female) (2) and A60 (female) (1)
Max. 1 z
value
with connector)
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.

Grounding fault of
wiring harness
(Contact with
grounding (GND)
circuit)
Short-circuiting of
wiring harness
(Contact with 24 V
circuit)

a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.

Between wiring harness between P02 (female) (2) and A60


(female) (1) and grounding

Between wiring harness between P02 (female) (2) and A60


(female) (1) and grounding

Resistance
value

Voltage

Min. 1 Mz

Max. 1 V

a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.
5

Monitor panel
defective

P01
Between (2) and grounding

Fuel level

Resistance value

FULL (Upper limit)

Approx. 12 z

EMPTY (Lower limit)

85 110 z

Electrical Circuit Diagram for Fuel Level Sensor

20-524
(5)

PC200/220(LC)-7

TROUBLESHOOTING

E-17

E-17 Swing lock monitor does not display correctly


Failure
information

Though the swing lock switch was turned ON, the swing lock monitor does not light up.
Though the swing lock switch was turned OFF, the swing lock monitor lights up.

Relative
information

Input from the swing lock switch (ON or OFF) can be confirmed in the monitor function.
(Code No. 049: Monitor input 3)
Cause

Presumed cause and standard value in normalcy

Swing lock switch


fault
(Internal disconnection or short-circuiting)

Standard value in normalcy and references for troubleshooting


a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.
X05 (female)
Between (1) and (2)

Swing lock switch

Resistance value

OFF

Min. 1 Mz

ON

Max. 1 z

a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
Disconnection of wirduring the troubleshooting.
ing harness
Wiring harness from P02 (female) (17) to J02 to X05 (male)
Resistance
(Disconnection or
Max. 1 z
(1)
value
defective contact
Resistance
with connector)
Wiring harness from X05 (male) (2) to J05 to grounding
Max. 1 z
value
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.

Grounding fault of
wiring harness
(Contact with
grounding (GND)
circuit)
Short-circuiting of
wiring harness
(Contact with 24 V
circuit)

a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.

Between wiring harness from P02 (female) (17) to J02 to X05


(male) (1), to C02 (female) (38) and grounding

Between wiring harness from P02 (female) (17) to J02 to X05


(male) (1), to C02 (female) (38) and grounding

Resistance
value

Voltage

Min. 1 Mz

Max. 1 V

a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.
5

Monitor panel
defective

P02
Between (17) and grounding

20-526
(5)

Swing lock switch

Voltage

OFF

20 30 V

ON

Max. 1 V

PC200/220(LC)-7

TESTING AND ADJUSTING

E-17

Electrical Circuit Diagram for Swing Lock Switch

PC200/220(LC)-7

20-527

TESTING AND ADJUSTING

E-18

E-18 When the monitor switch is operated, no display appears


Failure
information (1)

When operating the working mode changing switch, the working mode monitor does not appear.

Relative
information

Presumed
cause and
standard value
in normalcy

Cause
1

Monitor panel
defective

Standard value in normalcy and references for troubleshooting


As this is an internal failure, troubleshooting cannot be conducted.

Failure
information (2)

When operating the auto-decelerator switch, the auto-deceleration monitor does not appear.

Relative
information

If the auto-decelerator itself does not work, either, carry out No. E-5 Troubleshooting.

Presumed
cause and
standard value
in normalcy

Cause
1

Monitor panel
defective

Standard value in normalcy and references for troubleshooting


As this is an internal failure, troubleshooting cannot be conducted.

Failure
information (3)

When operating the travel speed shifting switch, the travel speed monitor does not appear.

Relative
information

If the travel speed does not actually change, carry out No. H-21 Troubleshooting.

Presumed
cause and
standard value
in normalcy

Cause
1

Monitor panel
defective

Standard value in normalcy and references for troubleshooting


As this is an internal failure, troubleshooting cannot be conducted.

Failure
information (4)

When operating the windshield wiper switch, the windshield wiper monitor does not appear.

Relative
information

If the windshield wiper itself does not work, either, carry out No. E-19 Troubleshooting.

Presumed
cause and
standard value
in normalcy

Cause
1

Monitor panel
defective

Standard value in normalcy and references for troubleshooting


As this is an internal failure, troubleshooting cannot be conducted.

Failure
information (5)

When operating the select switch, the adjustment display does not appear.
When operating the LCD monitor adjusting switch, the adjustment display does not appear.
When operating the maintenance switch, the item display does not appear.

Relative
information

Presumed
cause and
standard value
in normalcy

20-528

Cause
1

Monitor panel
defective

Standard value in normalcy and references for troubleshooting


As this is an internal failure, troubleshooting cannot be conducted.

PC200/220(LC)-7

TROUBLESHOOTING

E-19

E-19 Windshield wiper does not work


Failure
information

The windshield wiper does not work.

Relative
information

Input from the window rear limit switch (ON or OFF) can be confirmed in the monitor function.
(Code No. 049: Monitor input 3)
Cause

Presumed cause and standard value in normalcy

Window rear limit


switch fault
(Internal disconnection or short-circuiting)
Windshield wiper
motor fault
(Internal disconnection or short-circuiting)

Standard value in normalcy and references for troubleshooting


a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.
W03 (Switch side)
Between (1) and (2)

Front window

Resistance value

When installed at front

Min. 1 Mz

When retracted at rear

Max. 1 z

a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.
W04 (female)

Continuity and resistance value

Between (3) and (1)

Continued

Between (3) (1) and grounding

Min. 1 Mz

a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
Disconnection of wirduring the troubleshooting.
ing harness
Wiring harness between P01 (female) (9) and W04 (female)
Resistance
(Disconnection or
Max. 1 z
(3)
value
defective contact
Wiring harness between P01 (female) (10) and W04 (female)
Resistance
with connector)
Max. 1 z
(1)
value

Grounding fault of
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
wiring harness
during the troubleshooting.
(Contact with
Resistance
grounding (GND) cir- Between wiring harness between P02 (female) (15) and W03
Min. 1 Mz
(1)
value
cuit)
Monitor panel fault
(Rear limit switch
system)

P02
Between (15) and grounding

Front window

Voltage

When installed at front

20 30 V

When retracted at rear

Max. 1 V

a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.
Monitor panel fault
(Windshield wiper
motor system)

20-530
(5)

a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.

P01
Between (9) and grounding
Between (10) and grounding

Windshield wiper switch

Voltage

OFF

Max. 3 V

ON

Max. 3 V
20 30 V
(Constant cycle)

PC200/220(LC)-7

TESTING AND ADJUSTING

E-19

Electrical Circuit Diagram for Windshield Wiper Motor

PC200/220(LC)-7

20-531

TESTING AND ADJUSTING

E-20

E-20 Alarming buzzer cannot be cancelled


Failure
information

The alarming buzzer cannot be cancelled.

Relative
information

Input from the alarming buzzer cancellation switch (ON or OFF) can be confirmed in the monitor function.
(Code No. 049: Monitor input 3)

Presumed cause and standard value in normalcy

Cause

Alarming buzzer
cancellation switch
fault
(Internal disconnection or short-circuiting)

Standard value in normalcy and references for troubleshooting


Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.
P03 (female)
Between

and

Alarming buzzer
cancellation switch

Resistance value

Release

Above 1 M

Depress

Below 1

Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
Disconnection of wirduring the troubleshooting.
ing harness
Resistance
(Disconnection or
Below 1
Wiring harness between P02 (female)
and P03 (male)
value
defective contact
Resistance
with connector)
Below 1
Wiring harness from P03 (male)
to J05 to grounding
value

Short-circuiting of
wiring harness
(Contact with 24 V
circuit)

Turn the engine starting switch OFF for the preparations, and hold it in the ON position during the troubleshooting.
Between wiring harness between P02 (female)
(male)
and grounding

and P03

Voltage

Below 1 V

Turn the engine starting switch OFF for the preparations, and hold it in the ON position during the troubleshooting.
4

P02

Monitor panel fault


Between

and grounding

Alarming buzzer
cancellation switch

Voltage

Release

20 30 V

Depress

Below 1 V

Electrical Circuit Diagram for Alarming Buzzer Cancellation Switch

20-532

PC200/220(LC)-7

TROUBLESHOOTING

E-21

E-21 "Boom RAISE" is not correctly displayed in monitor function


Failure
information

"Boom RAISE" is not correctly displayed in the monitor function on the monitor panel.

Relative
information

Cause

Presumed cause and standard value in normalcy

Boom RAISE PPC


hydraulic switch fault
(Internal disconnection or short-circuiting)

Standard value in normalcy and references for troubleshooting


a Turn the engine starting switch OFF for the preparations, and keep the engine running
during the troubleshooting.
S06 (male)
Between (1) and (2)

Boom control lever

Resistance value

NEUTRAL

Min. 1 Mz

RAISE

Max. 1 z

a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
Disconnection of wirduring the troubleshooting.
ing harness
Wiring harness between C03 (female) (10) and S06 (female)
Resistance
(Disconnection or
Max. 1 z
(1)
value
defective contact
Resistance
with connector)
Wiring harness between S06 (female) (2) and grounding
Max. 1 z
value
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.

Grounding fault of
wiring harness
(Contact with
grounding (GND)
circuit)
Short-circuiting of
wiring harness
(Contact with 24 V
circuit)

a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.

Between wiring harness between C03 (female) (10) and S06


(female) (1) and grounding

Between wiring harness between C03 (female) (10) and S06


(female) (1) and grounding

Resistance
value

Voltage

Min. 1 Mz

Max. 1 V

a Turn the engine starting switch OFF for the preparations, start engine and carry out troubleshooting.
5

Governor pump
controller defective

C03
Between (10) and grounding

Boom control lever

Voltage

NEUTRAL

20 30 V

RAISE

Max. 1 V

Electrical Circuit Diagram for Boom RAISE PPC Hydraulic Switch

PC200/220(LC)-7

20-533
(5)

TROUBLESHOOTING

E-22

E-22 "Boom LOWER" is not correctly displayed in monitor function


Failure
information

"Boom LOWER" is not correctly displayed in the monitor function on the monitor panel.

Relative
information

Cause

Presumed cause and standard value in normalcy

Boom LOWER PPC


hydraulic switch fault
(Internal disconnection or short-circuiting)

Standard value in normalcy and references for troubleshooting


a Turn the engine starting switch OFF for the preparations, and keep the engine running
during the troubleshooting.
S02 (male)
Between (1) and (2)

Boom control lever

Resistance value

NEUTRAL

Min. 1 Mz

LOWER

Max. 1 z

a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
Disconnection of wirduring the troubleshooting.
ing harness
Wiring harness between C03 (female) (20) and S02 (female)
Resistance
(Disconnection or
Max. 1 z
(1)
value
defective contact
Resistance
with connector)
Wiring harness between S02 (female) (2) and grounding
Max. 1 z
value
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.

Grounding fault of
wiring harness
(Contact with
grounding (GND)
circuit)
Short-circuiting of
wiring harness
(Contact with 24 V
circuit)

a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.

Between wiring harness between C03 (female) (20) and S02


(female) (1) and grounding

Between wiring harness between C03 (female) (20) and S02


(female) (1) and grounding

Resistance
value

Voltage

Min. 1 Mz

Max. 1 V

a Turn the engine starting switch OFF for the preparations, start engine and carry out troubleshooting.
5

Governor pump
controller defective

C03
Between (20) and grounding

Boom control lever

Voltage

NEUTRAL

20 30 V

LOWER

Max. 1 V

Electrical Circuit Diagram for Boom LOWER PPC Hydraulic Switch

20-534
(5)

PC200/220(LC)-7

TROUBLESHOOTING

E-23

E-23 "Arm DIGGING" is not correctly displayed in monitor function


Failure
information

"Arm DIGGING" is not correctly displayed in the monitor function (special function) on the monitor panel.

Relative
information

Cause

Presumed cause and standard value in normalcy

Arm DIGGING PPC


hydraulic switch fault
(Internal disconnection or short-circuiting)

Standard value in normalcy and references for troubleshooting


a Turn the engine starting switch OFF for the preparations, and keep the engine running
during the troubleshooting.
S04 (male)
Between (1) and (2)

Arm control lever

Resistance value

NEUTRAL

Min. 1 Mz

DIGGING

Max. 1 z

a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
Disconnection of wirduring the troubleshooting.
ing harness
Wiring harness between C03 (female) (30) and S04 (female)
Resistance
(Disconnection or
Max. 1 z
(1)
value
defective contact
Resistance
with connector)
Wiring harness between S04 (female) (2) and grounding
Max. 1 z
value
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.

Grounding fault of
wiring harness
(Contact with
grounding (GND)
circuit)
Short-circuiting of
wiring harness
(Contact with 24 V
circuit)

a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.

Between wiring harness between C03 (female) (30) and S04


(female) (1) and grounding

Between wiring harness between C03 (female) (30) and S04


(female) (1) and grounding

Resistance
value

Voltage

Min. 1 Mz

Max. 1 V

a Turn the engine starting switch OFF for the preparations, start engine and carry out troubleshooting.
5

Governor pump
controller defective

C03
Between (30) and grounding

Arm control lever

Voltage

NEUTRAL

20 30 V

DIGGING

Max. 1 V

Electrical Circuit Diagram for Arm DIGGING PPC Hydraulic Switch

PC200/220(LC)-7

20-535
(5)

TROUBLESHOOTING

E-24

E-24 "Arm DUMPING" is not correctly displayed in monitor function


Failure
information

"Arm DUMPING" is not correctly displayed in the monitor function (special function) on the monitor panel.

Relative
information

Presumed cause and standard value in normalcy

Cause

Standard value in normalcy and references for troubleshooting

Arm DUMPING PPC a Turn the engine starting switch OFF for the preparations, and keep the engine running
during the troubleshooting.
hydraulic switch
defect
S08 (male)
Arm control lever
Resistance value
(Internal disconnecNEUTRAL
Min. 1 Mz
tion and short-circuitBetween (1) and (2)
ing)
DUMPING
Max. 1 z

a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
Disconnection of wirduring the troubleshooting.
ing harness
Wiring harness between C03 (female) (40) and S08 (female)
Resistance
(Disconnection or
Max. 1 z
(1)
value
defective contact
Resistance
with connector)
Wiring harness between S08 (female) (2) and grounding
Max. 1 z
value
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.

Grounding fault of
wiring harness
(Contact with
grounding (GND)
circuit)
Short-circuiting of
wiring harness
(Contact with 24 V
circuit)

a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.

Between wiring harness between C03 (female) (40) and S08


(female) (1) and grounding

Between wiring harness between C03 (female) (40) and S08


(female) (1) and grounding

Resistance
value

Voltage

Min. 1 Mz

Max. 1 V

a Turn the engine starting switch OFF for the preparations, start engine and carry out troubleshooting.
5

Governor pump
controller defective

C03
Between (40) and grounding

Arm control lever

Voltage

NEUTRAL

20 30 V

DUMPING

Max. 1 V

Electrical Circuit Diagram for Arm DUMPING PPC Hydraulic Switch

20-536
(5)

PC200/220(LC)-7

TROUBLESHOOTING

E-25

E-25 "Bucket DIGGING" is not correctly displayed in monitor function


Failure
information

"Bucket DIGGING" is not correctly displayed in the monitor function (special function) on the monitor panel.

Relative
information

Presumed cause and standard value in normalcy

Cause

Standard value in normalcy and references for troubleshooting

a Turn the engine starting switch OFF for the preparations, and keep the engine running
Bucket DIGGING
during the troubleshooting.
PPC hydraulic
switch fault
S01 (male)
Bucket control lever
Resistance value
(Internal disconnecNEUTRAL
Min. 1 Mz
tion and short-circuitBetween (1) and (2)
ing)
DIGGING
Max. 1 z

a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
Disconnection of wirduring the troubleshooting.
ing harness
Resistance
(Disconnection or
Wiring harness between C03 (female) (9) and S01 (female) (1)
Max. 1 z
value
defective contact
Resistance
with connector)
Wiring harness between S01 (female) (2) and grounding
Max. 1 z
value
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.

Grounding fault of
wiring harness
(Contact with
grounding (GND)
circuit)
Short-circuiting of
wiring harness
(Contact with 24 V
circuit)

a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.

Between wiring harness between C03 (female) (9) and S01


(female) (1) and grounding

Between wiring harness between C03 (female) (9) and S01


(female) (1) and grounding

Resistance
value

Voltage

Min. 1 Mz

Max. 1 V

a Turn the engine starting switch OFF for the preparations, start engine and carry out troubleshooting.
5

Governor pump
controller defective

C03
Between (9) and grounding

Bucket control lever

Voltage

NEUTRAL

20 30 V

DIGGING

Max. 1 V

Electrical Circuit Diagram for Bucket DIGGING PPC hydraulic Switch

PC200/220(LC)-7

20-537
(5)

TROUBLESHOOTING

E-26

E-26 "Bucket DUMPING" is not correctly displayed in monitor function


Failure
information

"Bucket DUMPING" is not correctly displayed in the monitor function (special function) on the monitor panel.

Relative
information

Presumed cause and standard value in normalcy

Cause

Standard value in normalcy and references for troubleshooting

a Turn the engine starting switch OFF for the preparations, and keep the engine running
Bucket DUMPING
during the troubleshooting.
PPC hydraulic
switch fault
S05 (male)
Bucket control lever
Resistance value
(Internal disconnecNEUTRAL
Min. 1 Mz
tion and short-circuitBetween (1) and (2)
ing)
DUMPING
Max. 1 z

a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
Disconnection of wirduring the troubleshooting.
ing harness
Wiring harness between C03 (female) (19) and S05 (female)
Resistance
(Disconnection or
Max. 1 z
(1)
value
defective contact
Resistance
with connector)
Wiring harness between S05 (female) (2) and grounding
Max. 1 z
value
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.

Grounding fault of
wiring harness
(Contact with
grounding (GND)
circuit)
Short-circuiting of
wiring harness
(Contact with 24 V
circuit)

a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.

Between wiring harness between C03 (female) (19) and S05


(female) (1) and grounding

Between wiring harness between C03 (female) (19) and S05


(female) (1) and grounding

Resistance
value

Voltage

Min. 1 Mz

Max. 1 V

a Turn the engine starting switch OFF for the preparations, start engine and carry out troubleshooting.
5

Governor pump
controller defective

C03
Between (19) and grounding

Bucket control lever

Voltage

NEUTRAL

20 30 V

DUMPING

Max. 1 V

Electrical Circuit Diagram for Bucket DUMPING PPC hydraulic Switch

20-538
(5)

PC200/220(LC)-7

TROUBLESHOOTING

E-27

E-27 "SWING" is not correctly displayed in monitor function


Failure
information

"SWING" is not correctly displayed in the monitor function (special function) on the monitor panel.

Relative
information

Cause

Presumed cause and standard value in normalcy

Swing PPC hydraulic


switch, left, fault
(Internal disconnection or short-circuiting)
Swing PPC hydraulic
switch, right, fault
(Internal disconnection or short-circuiting)

Standard value in normalcy and references for troubleshooting


a Turn the engine starting switch OFF for the preparations, and keep the engine running
during the troubleshooting.
S03 (male)
Between (1) and (2)

Swing control lever

Resistance value

NEUTRAL

Min. 1 Mz

Left

Max. 1 z

a Turn the engine starting switch OFF for the preparations, and keep the engine running
during the troubleshooting.
S07 (male)
Between (1) and (2)

Swing control lever

Resistance value

NEUTRAL

Min. 1 Mz

Right

Max. 1 z

a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.

Disconnection of wiring harness


(Disconnection or
defective contact
with connector)

Grounding fault of
wiring harness
(Contact with
grounding (GND)
circuit)
Short-circuiting of
wiring harness
(Contact with 24 V
circuit)

Wiring harness between C03 (female) (29) and S03 (female)


(1), or wiring harness between C03 (female) (29) and S07
(female) (1)

Resistance
value

Max. 1 z

Wiring harness between S03 (female) (2) and grounding

Resistance
value

Max. 1 z

Wiring harness between S07 (female) (2) and grounding

Resistance
value

Max. 1 z

a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.
Wiring harness between C03 (female) (29) and S03 (female)
(1), or wiring harness between C03 (female) (29) and S07
(female) (1) and grounding

Resistance
value

Min. 1 Mz

a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.
Wiring harness between C03 (female) (29) and S03 (female)
(1), or wiring harness between C03 (female) (29) and S07
(female) (1) and grounding

Voltage

Max. 1 V

a Turn the engine starting switch OFF for the preparations, start engine and carry out troubleshooting.
6

Governor pump
controller defective

C03
Between (29) and grounding

20-540
(5)

Swing control lever

Voltage

NEUTRAL

20 30 V

Right or left

Max. 1 V

PC200/220(LC)-7

TROUBLESHOOTING

E-27

Electrical Circuit Diagram for Right and Left Swing PPC hydraulic Switches

PC200/220(LC)-7

20-541
(1)

TROUBLESHOOTING

E-28

E-28 "TRAVEL" is not correctly displayed in monitor function


Failure
information

"TRAVEL" is not correctly displayed in the monitor function (special function) on the monitor panel.

Relative
information

Cause

Presumed cause and standard value in normalcy

Travel PPC hydraulic


switch fault
(Internal disconnection or short-circuiting)

Standard value in normalcy and references for troubleshooting


a Turn the engine starting switch OFF for the preparations, and keep the engine running
during the troubleshooting.
S30 (male)
Between (1) and (2)

Travel control lever

Resistance value

NEUTRAL

Min. 1 Mz

Forward or reverse

Max. 1 z

a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
Disconnection of wirduring the troubleshooting.
ing harness
Wiring harness from C03 (female) (39) to J01 to S30 (female)
Resistance
(Disconnection or
Max. 1 z
(2)
value
defective contact
Resistance
with connector)
Wiring harness from S30 (female) (2) to J05 to grounding
Max. 1 z
value

Grounding fault of
wiring harness
(Contact with
grounding (GND)
circuit)

Short-circuiting of
wiring harness
(Contact with 24 V
circuit)

a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.
Wiring harness from C03 (female) (39) to J01 to S30 (female)
(2), or between wiring harness between C03 (female) (39) and
A43 (female) (2) and grounding

Resistance
value

Min. 1 Mz

a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.
Wiring harness from C03 (female) (39) to J01 to S30 (female)
(2), or between wiring harness between C03 (female) (39) and
A43 (female) (2) and grounding

Voltage

Max. 1 V

a Turn the engine starting switch OFF for the preparations, start engine and carry out troubleshooting.
5

Governor pump
controller defective

C03
Between (39) and grounding

20-542
(5)

Travel control lever

Voltage

NEUTRAL

20 30 V

Forward or backward

Max. 1 V

PC200/220(LC)-7

TROUBLESHOOTING

E-28

Electrical Circuit Diagram for Travel PPC hydraulic Switch and Travel Alarm

PC200/220(LC)-7

20-543
(1)

TROUBLESHOOTING

E-29

E-29 "Travel Differential Pressure" is not correctly displayed in monitor function


Failure
information

"Travel Differential Pressure" is not correctly displayed in the monitor function (special function) on the monitor panel.

Relative
information

When pressure difference is created between the right and left travel PPC circuits (in steering), the travel
differential mechanism is turned ON.
Cause

Presumed cause and standard value in normalcy

Travel steering PPC


hydraulic switch fault
(Internal disconnection or short-circuiting)

Standard value in normalcy and references for troubleshooting


a Turn the engine starting switch OFF for the preparations, and keep the engine running
during the troubleshooting.
S31 (male)
Between (1) and (2)

Travel control lever

Resistance value

NEUTRAL

Min. 1 Mz

One side of right or left only

Max. 1 z

a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
Disconnection of wirduring the troubleshooting.
ing harness
Wiring harness between C03 (female) (16) and S31 (female)
Resistance
(Disconnection or
Max. 1 z
(2)
value
defective contact
Resistance
with connector)
Wiring harness from S31 (female) (2) to J05 to grounding
Max. 1 z
value
a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.

Grounding fault of
wiring harness
(Contact with
grounding (GND)
circuit)
Short-circuiting of
wiring harness
(Contact with 24 V
circuit)

a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.

Between wiring harness between C03 (female) (16) and S31


(female) (2) and grounding

Between wiring harness between C03 (female) (16) and S31


(female) (2) and grounding

Resistance
value

Voltage

Min. 1 Mz

Max. 1 V

a Turn the engine starting switch OFF for the preparations, start engine and carry out troubleshooting.
5

Governor pump
controller defective

C03
Between (16) and grounding

20-544
(5)

Travel control lever

Voltage

NEUTRAL

20 30 V

One side of right or left only

Max. 1 V

PC200/220(LC)-7

TROUBLESHOOTING

E-29

Electrical Circuit Diagram for Travel and Steering PPC hydraulic Switch

PC200/220(LC)-7

20-545
(1)

TROUBLESHOOTING

E-30

E-30 "Service" is not correctly displayed in monitor function


Equipped with attachment
Failure
information

"Service" is not correctly displayed in the monitor function (special function) on the monitor panel.

Relative
information

Cause

Presumed cause and standard value in normalcy

Service (front) PPC


hydraulic switch fault
(Internal disconnection or short-circuiting)
Service (rear) PPC
hydraulic switch fault
(Internal disconnection or short-circuiting)

Standard value in normalcy and references for troubleshooting


a Turn the engine starting switch OFF for the preparations, and keep the engine running
during the troubleshooting.
S10 (male)
Between (1) and (2)

Service pedal

Resistance value

NEUTRAL

Min. 1 Mz

Front

Max. 1 z

a Turn the engine starting switch OFF for the preparations, and keep the engine running
during the troubleshooting.
S11 (male)
Between (1) and (2)

Service pedal

Resistance value

NEUTRAL

Min. 1 Mz

Rear

Max. 1 z

a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.
Disconnection of wiring harness
Wiring harness between C03 (female) (35) and S10 (female)
Resistance
(Disconnection or
(1), or wiring harness between C03 (female) (35) and S11
Max. 1 z
value
defective contact
(female) (1)
with connector)
Resistance
Wiring harness between S10 (female) (2) and grounding
Max. 1 z
value

Grounding fault of
wiring harness
(Contact with
grounding (GND)
circuit)

Short-circuiting of
wiring harness
(Contact with 24 V
circuit)

a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.
Wiring harness between C03 (female) (35) and S10 (female)
(1), or between wiring harness between C03 (female) (35) and
S11 (female) (1) and grounding

Resistance
value

Min. 1 Mz

a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.
Wiring harness between C03 (female) (35) and S10 (female)
(1), or between wiring harness between C03 (female) (35) and
S11 (female) (1) and grounding

Voltage

Max. 1 V

a Turn the engine starting switch OFF for the preparations, start engine and carry out troubleshooting.
6

Governor pump
controller defective

C03
Between (35) and grounding

20-546
(5)

Service pedal

Voltage

NEUTRAL

20 30 V

Front or rear

Max. 1 V

PC200/220(LC)-7

TROUBLESHOOTING

E-30

Electrical Circuit Diagram for Service PPC hydraulic Switch

PC200/220(LC)-7

20-547
(5)

TROUBLESHOOTING

E-31

E-31 Troubleshooting for air conditioner system


PC200, 200LC-7 Serial No. 200001 250000
PC220, 220LC-7 Serial No. 60001 65000
The air conditioner does not work.

Relative
information

For the electrical circuit diagram inside the air conditioner unit, refer to the section of STRUCTURE AND
FUNCTION - Air Conditioner in this manual.

Presumed cause and standard value in normalcy

Failure
information

Cause

Standard value in normalcy and references for troubleshooting

Fuse No. 11 fault

When the fuse is blown, there is a big possibility that grounding fault occurred in the circuit.

a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
Disconnection of wirduring the troubleshooting.
ing harness
Resistance
(Disconnection or
Wiring harness between FB1-11 outlet and M26 (male) (4) (5)
Max. 1 z
value
defective contact
Resistance
with connector)
Wiring harness between M26 (male) (8) and grounding
Max. 1 z
value

Grounding fault of
wiring harness
(Contact with
grounding (GND)
circuit)

Air conditioner unit


defective

a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.
Between wiring harness between FB1-11 outlet and M26
(male) (4) (5) and grounding

Voltage

Min. 1 Mz

a Turn the engine starting switch OFF for the preparations, and hold it in the ON position
during the troubleshooting.
M26

Voltage

Between (4) (5) and (8)

20 30 V

Electrical Circuit Diagram for Air Conditioner

20-548
(7)

PC200/220(LC)-7

TROUBLESHOOTING

E-31

PC200, 200LC-7 Serial No. 250001 and up


PC220, 220LC-7 Serial No. 65001 and up
Troubleshooting procedure for air conditioner system
a The control panel of the air conditioner constantly monitors the sensors and other devices in the system .
When it detects any abnormality, Self-diagnosis notice is displayed by operating switches specially.
a If you feel any abnormality in the air conditioner system, check the Self-diagnosis notice first according to
the procedure for Troubleshooting by self-diagnosis notice, and then;
If the Self-diagnosis notice is displayed, continue the Troubleshooting by self-diagnosis notice.
If the Self-diagnosis notice is not displayed, carry out the Troubleshooting by failure phenomenon.

Troubleshooting by self-diagnosis notice


a Check the Self-diagnosis notice on the control
panel according to the following procedure.

How to display Self-diagnosis notice


1) Turn the starting switch ON.
2) Press OFF switch (1) and check that anything is not displayed on display monitor (2).
3) Hold the UP switch ( ) and DOWN switch
( ) of temperature setting switch (3) simultaneously for 3 seconds or more.
4) Check the Self-diagnosis notice displayed
on display monitor (2).

How to select Self-diagnosis notice


If multiple Self-diagnosis notices are recorded,
press the UP switch ( ) or DOWN switch ( )
of temperature setting switch (3) to select
another notice.

How to delete Self-diagnosis notice


When reproducing the Self-diagnosis notices
or after removing the cause of a failure, press
the switches on both sides of recirc/fresh air
selector switch (4) simultaneously for 3 seconds
or more, and all the Self-diagnosis notices are
deleted.

Finishing display of Self-diagnosis notice


To finish display of the Self-diagnosis notice,
press OFF switch (1) or turn the starting switch
OFF.

PC200/220(LC)-7

Self-diagnosis
Failure mode
notice
E-No failures
Disconnection in recirculated air
E11
sensor
Short-circuit in recirculated air senE12
sor
Disconnection in coolant temperaE15
ture sensor
Short-circuit in coolant temperature
E16
sensor
E18
Short-circuit in daylight sensor
E43
Abnormality in air outlet damper
E44
Abnormality in air mix damper
Abnormality in recirculated and fresh
E45
air damper

20-549
(11)

TROUBLESHOOTING

Self-diagnosis
notice

Trouble

E-31

Disconnection in recirculated air sensor

E11
Contents of
trouble
Action of
control panel

Disconnection in the recirculated air sensor system is detected.


Fixes the recirculated air temperature for control.
When the following condition is satisfied, the operation returns to normalcy.
<Completion of removal of cause> + <Deletion of self-diagnosis notice> + <Turning starting switch OFF
and ON> + <Starting air conditioner>

Related
information

Possible causes and


standard value in normal state

Cause

Standard value in normal state/Remarks on troubleshooting

Defective recirculated
1 air sensor
(Internal disconnection)

Disconnection of wiring
harness (Disconnection
2
or defective contact with
connector)

Defective air conditioner


system

Self-diagnosis
notice

Trouble

a Prepare with starting switch OFF, then carry out troubleshooting without turning
starting switch ON.
THI (male)

Resistance

Between (1) and (2)

300 z 430 kz

a Prepare with starting switch OFF, then carry out troubleshooting without turning
starting switch ON.
Wiring harness between M30 (female) (12) and TH I
(female) (2)

Resistance

Max. 1 z

Wiring harness between M29 (female) (11) and TH I


(female) (1)

Resistance

Max. 1 z

If neither of causes 1 and 2 is the cause of the trouble, the air conditioner system
may be defective. Refer to CHASSIS COMPONENT, Shop Manual, Air conditioner.

Short circuit in recirculated air sensor

E12
Contents of
trouble
Action of
control panel

Short circuit in the recirculated air sensor system is detected.


Fixes the recirculated air temperature for control.
When the following condition is satisfied, the operation returns to normalcy.
<Completion of removal of cause> + <Deletion of self-diagnosis notice> + <Turning starting switch OFF
and ON> + <Starting air conditioner>

Related
information

Possible causes and


standard value in normal state

Cause
Defective recirculated air
1 sensor (Internal short circuit)

Disconnection of wiring
harness (Disconnection
2
or defective contact with
connector)

20-550
(5)

Defective air conditioner


system

Standard value in normal state/Remarks on troubleshooting


a Prepare with starting switch OFF, then carry out troubleshooting without turning
starting switch ON.
THI (male)

Resistance

Between (1) and (2)

300 z 430 kz

a Prepare with starting switch OFF, then carry out troubleshooting without turning
starting switch ON.
Wiring harness between M30 (female) (12) and TH I
(female) (2)

Resistance

Max. 1 z

Wiring harness between M29 (female) (11) and TH I


(female) (1)

Resistance

Max. 1 z

If neither of causes 1 and 2 is the cause of the trouble, the air conditioner system
may be defective. Refer to CHASSIS COMPONENT, Shop Manual, Air conditioner.

PC200/220(LC)-7

TROUBLESHOOTING

Self-diagnosis
notice

Trouble

E-31

Disconnection in coolant temperature sensor

E15
Contents of
trouble
Action of
control panel

Disconnection in the coolant temperature sensor system is detected.


Ignores the warm-up control and fixes the engine coolant temperature at 60C for control.
When the following condition is satisfied, the operation returns to normalcy.
<Completion of removal of cause> + <Deletion of self-diagnosis notice> + <Turning starting switch OFF
and ON> + <Starting air conditioner>

Related
information

Possible causes and


standard value in normal state

Cause

Standard value in normal state/Remarks on troubleshooting

Defective coolant tem1 perature sensor (Internal


disconnection)

Disconnection of wiring
harness (Disconnection
2
or defective contact with
connector)

Defective air conditioner


system

Self-diagnosis
notice

Trouble

a Prepare with starting switch OFF, then carry out troubleshooting without turning
starting switch ON.
THW (male)

Resistance

Between (1) and (2)

95 z 455 kz

a Prepare with starting switch OFF, then carry out troubleshooting without turning
starting switch ON.
Wiring harness between M30 (female) (14) and THW
(female) (2)

Resistance

Max. 1 z

Wiring harness between M29 (female) (11) and THW


(female) (1)

Resistance

Max. 1 z

If neither of causes 1 and 2 is the cause of the trouble, the air conditioner system
may be defective. Refer to CHASSIS COMPONENT, Shop Manual, Air conditioner.

Short circuit in coolant temperature sensor

E16
Contents of
trouble
Action of
control panel

Short circuit in the coolant temperature sensor system is detected.


Ignores the warm-up control and fixes the engine coolant temperature at 60C for control.
When the following condition is satisfied, the operation returns to normalcy.
<Completion of removal of cause> + <Deletion of self-diagnosis notice> + <Turning starting switch OFF
and ON> + <Starting air conditioner>

Related
information

Possible causes and


standard value in normal state

Cause
Defective coolant tem1 perature sensor (Internal
short circuit)

Disconnection of wiring
harness (Disconnection
2
or defective contact with
connector)

Defective air conditioner


system

PC200/220(LC)-7

Standard value in normal state/Remarks on troubleshooting


a Prepare with starting switch OFF, then carry out troubleshooting without turning
starting switch ON.
THW (male)

Resistance

Between (1) and (2)

95 z 455 kz

a Prepare with starting switch OFF, then carry out troubleshooting without turning
starting switch ON.
Wiring harness between M30 (female) (14) and THW
(female) (2)

Resistance

Max. 1 z

Wiring harness between M29 (female) (11) and THW


(female) (1)

Resistance

Max. 1 z

If neither of causes 1 and 2 is the cause of the trouble, the air conditioner system
may be defective. Refer to CHASSIS COMPONENT, Shop Manual, Air conditioner.

20-551
(11)

TROUBLESHOOTING

Self-diagnosis
notice

Trouble

E-31

Short circuit in daylight sensor

E18
Contents of
trouble
Action of
control panel

Short circuit in the daylight sensor system is detected.


Assumes that the daylight sensor is not installed for control.
When the following condition is satisfied, the operation returns to normalcy.
<Completion of removal of cause> + <Deletion of self-diagnosis notice> + <Turning starting switch OFF
and ON> + <Starting air conditioner>

Related
information
Possible causes and
standard value in normal state

Cause

Standard value in normal state/Remarks on troubleshooting

Defective daylight sen1


The daylight sensor may be defective. Check it directly.
sor (Internal short circuit)
Disconnection of wiring
harness (Disconnection
2
or defective contact with
connector)

Defective air conditioner


system

Self-diagnosis
notice

Trouble

a Prepare with starting switch OFF, then carry out troubleshooting without turning
starting switch ON.
Wiring harness between M30 (female) (16) and P15
(female) (2)

Resistance

Max. 1 z

Wiring harness between M30 (female) (3) and P15


(female) (1)

Resistance

Max. 1 z

If neither of causes 1 and 2 is the cause of the trouble, the air conditioner system
may be defective. Refer to CHASSIS COMPONENT, Shop Manual, Air conditioner.

Abnormality in air outlet damper

E43
Contents of
trouble

Abnormality in air outlet servomotor system is detected.

Action of
control panel

Stops the air outlet servomotor.


When the following condition is satisfied, the operation returns to normalcy.
<Completion of removal of cause> + <Deletion of self-diagnosis notice> + <Turning starting switch OFF
and ON> + <Starting air conditioner>

Related
information

a Do not connect the power cables to the motor terminals directly to drive the motor. Doing so can damage
the motor output shaft and break the motor coils.
Cause

Standard value in normalcy and references for troubleshooting

Possible causes and


standard value in normal state

Defective air outlet servo1


The air outlet servomotor may be defective. Check it directly.
motor (Internal defect)
a Prepare with starting switch OFF, then carry out troubleshooting without turning
starting switch ON.

Disconnection in wiring
harness (Disconnection
2 in wiring harness or
defective contact in connector)

20-552
(5)

Defective air conditioner


system

Wiring harness between MV1 (female) (1) and M30


(female) (3)

Resistance

Max. 1 z

Wiring harness between MV1 (female) (3) and M29


(female) (11)

Resistance

Max. 1 z

Wiring harness between MV1 (female) (5) and M30


(female) (9)

Resistance

Max. 1 z

Wiring harness between MV1 (female) (6) and M29


(female) (8)

Resistance

Max. 1 z

Wiring harness between MV1 (female) (7) and M29


(female) (9)

Resistance

Max. 1 z

If none of causes 1 and 2 is the cause of the trouble, the air conditioner system may
be defective. Refer to CHASSIS COMPONENT, Shop Manual, Air conditioner.

PC200/220(LC)-7

TROUBLESHOOTING

Self-diagnosis
notice

Trouble

E-31

Abnormality in air mix damper

E44
Contents of
trouble

Abnormality in air mix servomotor system is detected.

Action of
control panel

Stops the air mix servomotor.


When the following condition is satisfied, the operation returns to normalcy.
<Completion of removal of cause> + <Deletion of self-diagnosis notice> + <Turning starting switch OFF
and ON> + <Starting air conditioner>

Related
information

a Do not connect the power cables to the motor terminals directly to drive the motor. Doing so can damage
the motor output shaft and break the motor coils.
Cause

Possible causes and


standard value in normal state

Defective air mix servo1


motor (Internal defect)

Standard value in normal state/Remarks on troubleshooting


The air mix servomotor may be defective. Check it directly.
a Prepare with starting switch OFF, then carry out troubleshooting without turning
starting switch ON.

Disconnection in wiring
harness (Disconnection
2 in wiring harness or
defective contact in connector)

Defective air conditioner


system

PC200/220(LC)-7

Wiring harness between MAM (female) (1) and M29


(female) (11)

Resistance

Max. 1 z

Wiring harness between MAM (female) (3) and M30


(female) (3)

Resistance

Max. 1 z

Wiring harness between MAM (female) (5) and M30


(female) (2)

Resistance

Max. 1 z

Wiring harness between MAM (female) (6) and M29


(female) (4)

Resistance

Max. 1 z

Wiring harness between MAM (female) (7) and M29


(female) (5)

Resistance

Max. 1 z

If neither of causes 1 and 2 is the cause of the trouble, the air conditioner system
may be defective. Refer to CHASSIS COMPONENT, Shop Manual, Air conditioner.

20-553
(5)

TROUBLESHOOTING

Self-diagnosis
notice

Trouble

E-31

Abnormality in recirculated and fresh air damper

E45
Contents of
trouble

Abnormality in recirculated and fresh air servomotor system is detected.

Action of
control panel

Stops the recirculated and fresh air servomotor.


When the following condition is satisfied, the operation returns to normalcy.
<Completion of removal of cause> + <Deletion of self-diagnosis notice> + <Turning starting switch OFF
and ON> + <Starting air conditioner>

Related
information

a Do not connect the power cables to the motor terminals directly to drive the motor. Doing so can damage
the motor output shaft and break the motor coils.

Possible causes and


standard value in normal state

Cause

The recirculated and fresh air servomotor may be defective. Check it directly.

2 Defective fuse (in unit)

If the fuse (in the unit) is broken, the circuit probably has a grounding fault, etc.
Check the related circuits.
a Prepare with starting switch OFF, then carry out troubleshooting without turning
starting switch ON.

Disconnection in wiring
harness (Disconnection
3 in wiring harness or
defective contact in connector)

20-554
(5)

Standard value in normal state/Remarks on troubleshooting

Defective recirculated
1 and fresh air servomotor
(Internal defect)

Defective air conditioner


system

Wiring harness between MRF (female) (1) and M29


(female) (6)

Resistance

Max. 1 z

Wiring harness between MRF (female) (3) and M29


(female) (7)

Resistance

Max. 1 z

Wiring harness between MRF (female) (7), fuse in unit,


and M33 (female) (3)

Resistance

Max. 1 z

If none of causes 1 3 is the cause of the trouble, the air conditioner system may be
defective. Refer to CHASSIS COMPONENT, Shop Manual, Air conditioner.

PC200/220(LC)-7

TROUBLESHOOTING

E-31

Electrical Circuit Diagram for Air Conditioner

PC200/220(LC)-7

20-555
(5)

TROUBLESHOOTING

E-31

Troubleshooting by failure phenomenon


Trouble

The air conditioner does not operate.

(1) The air conditioner does not operate at all.

Related
information
Cause
1 Defective fuse No. 11

Standard value in normal state/Remarks on troubleshooting


If the fuse is broken, the circuit probably has a grounding fault, etc. (Refer to cause
3.)
a Prepare with starting switch OFF, then carry out troubleshooting without turning
starting switch ON.

Possible causes and


standard value in normal state

Disconnection in wiring
harness (Disconnection
2 in wiring harness or
defective contact in connector)

Short circuit with chassis


ground in wiring harness
3
(Contact with ground circuit)

Wiring harness between fuse 11 outlet and M33 (male)


(3)

Resistance

Max. 1z

Wiring harness between M27 (female) (14) and M30


(female) (6)

Resistance

Max. 1z

Wiring harness between M33 (male) (3) and chassis


ground

Resistance

Max. 1z

Wiring harness between M29 (female) (12) and chassis


ground

Resistance

Max. 1z

a Prepare with starting switch OFF, then carry out troubleshooting without turning
starting switch ON.
Between wiring harness between circuit breaker fuse 11
outlet and M33 (male) (3) and chassis ground

Resistance

Min. 1 Mz

Between wiring harness between M27 (female) (14) and


M30 (female) (6) and chassis ground

Resistance

Min. 1 Mz

a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting.
4

Defective air conditioner


unit

M33

Voltage

Between (2) and (3)

20 V 30 V

If the above voltage is normal and the air conditioner does not operate, the air conditioner is defective.
a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting.
5 Defective control panel

M30, M29

Voltage

Between M30 (6) and M29 (12)

20 V 30 V

If the above voltage is normal and the air conditioner does not operate, the control
panel is defective.

20-556
(5)

PC200/220(LC)-7

TROUBLESHOOTING

Trouble

E-31

The air conditioner does not operate.

(2) Air does not come out (Air flow is insufficient).

Related
information
Cause
1 Defective fuse (in unit)

Possible causes and


standard value in normal state

Defective blower relay


(on coil side)

Defective blower relay


(on contact side)

Defective power transistor (Internal defect)

Standard value in normal state/Remarks on troubleshooting


If the fuse (in the unit) is broken, the circuit probably has a grounding fault, etc.
Check the related circuits.
a Prepare with starting switch OFF, then carry out troubleshooting without turning
starting switch ON.
R30 (male)

Resistance

Between (1) and (3)

140 340 z

a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting.
R30

Fan switch

Voltage

Between (4) and


chassis ground

ON (Operated)

20 30 V

a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting.
Fan switch
Operate in range of Low, Medium, and
High

If air flow can be changed with fan switch,


power transistor is normal.

a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting.
5

Defective blower motor


(Internal defect)

MB (female)

Fan switch

Voltage

Between (1) and (2)

ON (Operated)

20 30 V

If the above voltage is normal and the blower motor does not rotate, the blower motor
is defective.
a Prepare with starting switch OFF, then carry out troubleshooting without turning
starting switch ON.

Disconnection in wiring
harness (Disconnection
6 in wiring harness or
defective contact in connector)

Defective air conditioner


system

PC200/220(LC)-7

Wiring harness between fuse 11 outlet, fuse in unit, R30


(3), R31 (female) (1), and M30 (female) (6)

Resistance

Max. 1 z

Wiring harness between M29 (female) (3) and R30


(female) (1)

Resistance

Max. 1 z

Wiring harness between M29 (female) (12) and chassis


ground

Resistance

Max. 1 z

Wiring harness between MB (female) (1) and R30


(female) (4)

Resistance

Max. 1 z

Wiring harness between MB (female) (2) and PTR


(female) (3)

Resistance

Max. 1 z

Wiring harness between PTR (female) (1) and chassis


ground

Resistance

Max. 1 z

Wiring harness between PTR (female) (2) and M30


(female) (7)

Resistance

Max. 1 z

Wiring harness between PTR (female) (4) and M30


(female) (8)

Resistance

Max. 1 z

If none of causes 1 6 is the cause of the trouble, the air conditioner system may be
defective. Refer to CHASSIS COMPONENT, Shop Manual, Air conditioner.

20-557
(5)

TROUBLESHOOTING

Trouble

E-31

The air conditioner does not operate.

(3) Air is not cooled (Cooling capacity is low).

Related
information
Cause
1 Defective fuse (in unit)

Possible causes and


standard value in normal state

Defective compressor
relay (on coil side)

Defective compressor
relay (on contact side)

Defective thermostat
(Internal defect)

Defective high/low pres5 sure switch (Internal disconnection)

a Prepare with starting switch OFF, then carry out troubleshooting without turning
starting switch ON.
R31 (male)

Resistance

Between (1) and (2)

140 340 z

a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting (Setting of temperature: Highest cooling position).
R31

Fan switch

Voltage

Between (4) and chassis


ground

ON (Operated)

20 30 V

The thermostat may be defective. Check it directly.


a Prepare with starting switch OFF, then carry out troubleshooting without turning
starting switch ON.
P17 (male)

Resistance

Between (1) and (2)

Max. 1 z

Defective compressor
clutch (Internal defect)

The compressor clutch may be defective. Check it directly.

Defective compressor
(Internal defect)

The compressor may be defective. Check it directly.


a Prepare with starting switch OFF, then carry out troubleshooting without turning
starting switch ON.

Disconnection in wiring
harness (Disconnection
8 in wiring harness or
defective contact in connector)

20-558
(5)

Standard value in normal state/Remarks on troubleshooting


If the fuse (in the unit) is broken, the circuit probably has a grounding fault, etc.
Check the related circuits.

Defective air conditioner


system

Wiring harness between M30 (female) (4) and P17


(female) (1)

Resistance

Max. 1 z

Wiring harness between P17 (female) (2) and chassis


ground

Resistance

Max. 1 z

Wiring harness between fuse 11 outlet, R31 (female)


(2), fuse in unit, R31 (female) (1), and M30 (female) (6)

Resistance

Max. 1 z

Wiring harness between ST1 (female) (1) and R31


(female) (3)

Resistance

Max. 1 z

Wiring harness between M29 (female) (2) and ST1


(female) (2)

Resistance

Max. 1 z

Wiring harness between M29 (female) (12) and chassis


ground

Resistance

Max. 1 z

Wiring harness between R31 (female) (4) and M34


(female) (1)

Resistance

Max. 1 z

If none of causes 1 8 is the cause of the trouble, the air conditioner system may be
defective. Refer to CHASSIS COMPONENT, Shop Manual, Air conditioner.

PC200/220(LC)-7

TROUBLESHOOTING

E-31

Electrical Circuit Diagram for Air Conditioner

PC200/220(LC)-7

20-559
(5)

TROUBLESHOOTING

E-32

E-32 Travel alarm does not sound


Equipped with travel alarm
Failure
information

The travel alarm does not sound while the machine is traveling.
The alarm begins to sound when the machine is at a standstill.

Relative
information

Presumed cause and standard value in normalcy

Cause

Standard value in normalcy and references for troubleshooting

Fuse No. 15 fault

When the fuse is blown, there is a big possibility that grounding fault occurred in the circuit.
(Refer to cause 4)
If the monitor display is not correct, proceed to No. E-21 Troubleshooting.

Travel signal fault

Monitoring code
019

Item

Normal display

Travel

Control lever operation: ON


Control lever NEUTRAL: OFF

a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
Disconnection of wirduring the troubleshooting.
ing harness
Wiring harness between FB1-15 outlet to J03 and A43
Resistance
(Disconnection or
Max. 1 z
(female) (1)
value
defective contact
Resistance
with connector)
Wiring harness between A43 (female) (2) and J01 (19)
Max. 1 z
value

Grounding fault of
wiring harness
(Contact with
grounding (GND)
circuit)

Travel alarm fault

a Turn the engine starting switch OFF for the preparations, and hold it in the OFF position
during the troubleshooting.
Between wiring harness between FB1-15 outlet to J03 and
A43 (female) (1) and grounding

Resistance
value

Min. 1 Mz

As this is an internal failure, troubleshooting cannot be conducted. (If none of the causes
listed in Item 1 through 4 above is found, the travel alarm is judged as defective)

Electrical Circuit Diagram for Travel PPC Hydraulic Switch and Travel Alarm

20-560
(5)

PC200/220(LC)-7