ENMAS O & M SERVICES PRIVA

2 * 35 MW POWER PLANT , TULSYAN NEC LIMITED.GUM


EQUIPMENT HISTORY CARD
AREA
NAME OF THE EQUIPMENT

: ACC
: Oil level switch

EQUIPMENT CODE

: TNL/CPP/ACC/OLS/002

EQUIPMENT DETAILS

DATE

ACD Machine Control

DESCRIPTION OF THE WORK DONE

30.07.2014

switch was cleaned, then oil top up by mech dept

27.03.2015

switch was cleaned and inspection work done

28.09.2015

switch was cleaned and inspection work done

26.01.2016

switch was cleaned and inspection work done

27.02.2016

switch was cleaned and inspection work done

TYPE OF WORK : PM - Preventive maint.

CBM- Condition based maint. SD - Shutdown maint. BD - Break down maint.

DATE

DESCRIPTION OF THE WORK DONE

TYPE OF WORK : PM - Preventive maint.

CBM- Condition based maint. SD - Shutdown maint. BD - Break down maint.

RVICES PRIVATE LIMITED.

SYAN NEC LIMITED.GUMMIDIPOONDI - 601201.

MENT HISTORY CARD


FORMET NO : 001

TYPE OF WORK

MANNING

SPARES CONSUMED

CBM

NIL

SD

NIL

SD

NIL

SD

NIL

SD

NIL

INCHARGE SIGNATURE

int. BD - Break down maint. OTH : Other maint.

TYPE OF WORK

MANNING

SPARES CONSUMED

INCHARGE SIGNATURE
1
2

int. BD - Break down maint. OTH : Other maint.

ENMAS O & M SERVICES PRIVA

2 * 35 MW POWER PLANT , TULSYAN NEC LIMITED.GUM


EQUIPMENT HISTORY CARD
AREA
NAME OF THE EQUIPMENT

: ACC
: Oil level switch

EQUIPMENT CODE

: TNL/CPP/ACC/OLS /001

EQUIPMENT DETAILS

DATE
29.07.2014

ACD Machine Control

DESCRIPTION OF THE WORK DONE


switch was cleaned, then oil top up by mech dept

04.02.2015

ACC FAN - 1 Oil level switch was checked

23.03.2015

ACC FAN - 1 Oil level switch was checked

09.04.2015

ACC FAN - 1 Oil level switch was checked

25.06.2015

ACC FAN - 1 Oil level switch was checked

28.06.2015

ACC FAN - 1 Oil level switch was checked

28.09.2015

switch was cleaned and inspection work done

26.01.2016

switch was cleaned and inspection work done

27.02.2016

switch was cleaned and inspection work done

TYPE OF WORK : PM - Preventive maint.

CBM- Condition based maint. SD - Shutdown maint. BD - Break down maint.

DATE

DESCRIPTION OF THE WORK DONE

TYPE OF WORK : PM - Preventive maint.

CBM- Condition based maint. SD - Shutdown maint. BD - Break down maint.

RVICES PRIVATE LIMITED.

SYAN NEC LIMITED.GUMMIDIPOONDI - 601201.

MENT HISTORY CARD


FORMET NO : 001

TYPE OF WORK

MANNING

SPARES CONSUMED

CBM

NIL

CBM

NIL

CBM

NIL

CBM

NIL

SD

NIL

SD

NIL

SD

NIL

SD

NIL

SD

NIL

INCHARGE SIGNATURE

int. BD - Break down maint. OTH : Other maint.

TYPE OF WORK

MANNING

SPARES CONSUMED

INCHARGE SIGNATURE

int. BD - Break down maint. OTH : Other maint.

ENMAS O & M SERVICES PRIVA

2 * 35 MW POWER PLANT , TULSYAN NEC LIMITED.GUM


EQUIPMENT HISTORY CARD
AREA
NAME OF THE EQUIPMENT

: ACC
: Oil level switch

EQUIPMENT CODE

: TNL/CPP/ACC/OLS /003

EQUIPMENT DETAILS

: ACD Machine Control

DATE

DESCRIPTION OF THE WORK DONE

09.03.2014

Oil level switch was cleaned and now fan is running normally.

11.06.2015

ACC FAN - 3 Oil level switch was checked. Found normal

29.06.2015

ACC FAN - 3 Oil level switch was checked.

28.09.2015

switch was cleaned and inspection work done

26.01.2016

switch was cleaned and inspection work done

27.02.2016

switch was cleaned and inspection work done

TYPE OF WORK : PM - Preventive maint.

CBM- Condition based maint. SD - Shutdown maint. BD - Break down maint.

DATE

DESCRIPTION OF THE WORK DONE

TYPE OF WORK : PM - Preventive maint.

CBM- Condition based maint. SD - Shutdown maint. BD - Break down maint.

RVICES PRIVATE LIMITED.

SYAN NEC LIMITED.GUMMIDIPOONDI - 601201.

MENT HISTORY CARD


FORMET NO : 001

TYPE OF WORK

MANNING

SPARES CONSUMED

CBM

NIL

CBM

NIL

CBM

NIL

SD

NIL

SD

NIL

SD

NIL

INCHARGE SIGNATURE

int. BD - Break down maint. OTH : Other maint.

TYPE OF WORK

MANNING

SPARES CONSUMED

INCHARGE SIGNATURE

int. BD - Break down maint. OTH : Other maint.

ENMAS O & M SERVICES PRIVA

2 * 35 MW POWER PLANT , TULSYAN NEC LIMITED.GUM


EQUIPMENT HISTORY CARD
AREA
NAME OF THE EQUIPMENT

: ACC
: Oil level switch

EQUIPMENT CODE

: TNL/CPP/ACC/OLS /004

EQUIPMENT DETAILS

: ACD Machine Control

DATE

DESCRIPTION OF THE WORK DONE

02.10.2013

Found float fully jammed condition.Switch cleaned. Checked found normal.

06.11.2013

Found oil level was low. After top up it was normal.

13.03.2014

Oil level switch was cleaned and now fan is running normally.

21.04.2014

Oil level switch removed then, inserting tube hole dia was increased .

12.05.2014

Oil was below the normal level and viscosity was bad, oil was top up work done

01.05.2014

Level Switch was cleaned .

27.10.2014

ACC- 4 oil level Switch was checked and found normal

10.11.2014

ACC fan 4 oil level switch is interchanged to ACC fan 8

10.1.2015

ACC fan - 4, 6 oil level switches was inspected. Found normal

12.02.2015

ACC FAN - 4 Oil level switch was checked

28.06.2015

ACC FAN - 4 Oil level switch was checked

03.09.2015

ACC FAN - 4 Oil level switch was checked

28.09.2015

switch was cleaned and inspection work done

26.01.2016

switch was cleaned and inspection work done

28.02.2016

Capacitance type switch was replaced

TYPE OF WORK : PM - Preventive maint.

CBM- Condition based maint. SD - Shutdown maint. BD - Break down maint.

DATE

DESCRIPTION OF THE WORK DONE

TYPE OF WORK : PM - Preventive maint.

CBM- Condition based maint. SD - Shutdown maint. BD - Break down maint.

RVICES PRIVATE LIMITED.

SYAN NEC LIMITED.GUMMIDIPOONDI - 601201.

MENT HISTORY CARD


FORMET NO : 001

TYPE OF WORK

MANNING

SPARES CONSUMED

CBM

NIL

CBM

NIL

CBM

NIL

CBM

NIL

CBM

NIL

CBM

NIL

CBM

NIL

CBM

NIL

SD

NIL

CBM

NIL

CBM

NIL

CBM

NIL

INCHARGE SIGNATURE

SD

NIL

SD

NIL

SD

NIL

int. BD - Break down maint. OTH : Other maint.

TYPE OF WORK

MANNING

SPARES CONSUMED

INCHARGE SIGNATURE

int. BD - Break down maint. OTH : Other maint.

ENMAS O & M SERVICES PRIVA

2 * 35 MW POWER PLANT , TULSYAN NEC LIMITED.GUM


EQUIPMENT HISTORY CARD
AREA
NAME OF THE EQUIPMENT

: ACC
: Oil level switch

EQUIPMENT CODE

: TNL/CPP/ACC/OLS /005

EQUIPMENT DETAILS

: ACD Machine Control

DATE

DESCRIPTION OF THE WORK DONE

10.03.2014

Found oil level float was revesed position.Now switch cleaned and fixed.

06.09.2014

ACC- 5 oil level Switch was checked and Found normal

23.10.2014

ACC- 5 oil level Switch was checked and Found normal

19.06.2015

ACC- 5 oil level Switch was checked and Found normal

02.08.2015

ACC fan - 5 oil level switch was checked. Oil top upped - 2 litters

06.08.2015

ACC fan - 2 oil level switch was checked.

28.09.2015

switch was cleaned and inspection work done

26.01.2016

switch was cleaned and inspection work done

27.02.2016

switch was cleaned and inspection work done

14.03.2016

switch was cleaned and inspection work done

TYPE OF WORK : PM - Preventive maint.

CBM- Condition based maint. SD - Shutdown maint. BD - Break down maint.

DATE

DESCRIPTION OF THE WORK DONE

TYPE OF WORK : PM - Preventive maint.

CBM- Condition based maint. SD - Shutdown maint. BD - Break down maint.

RVICES PRIVATE LIMITED.

SYAN NEC LIMITED.GUMMIDIPOONDI - 601201.

MENT HISTORY CARD


FORMET NO : 001

TYPE OF WORK

MANNING

SPARES CONSUMED

CBM

NIL

CBM

NIL

CBM

NIL

CBM

NIL

CBM

NIL

CBM

NIL

SD

NIL

SD

NIL

SD

NIL

CBM

NIL

INCHARGE SIGNATURE

int. BD - Break down maint. OTH : Other maint.

TYPE OF WORK

MANNING

SPARES CONSUMED

INCHARGE SIGNATURE

int. BD - Break down maint. OTH : Other maint.

ENMAS O & M SERVICES PRIVA

2 * 35 MW POWER PLANT , TULSYAN NEC LIMITED.GUM


EQUIPMENT HISTORY CARD
AREA
NAME OF THE EQUIPMENT

: ACC
: Oil level switch

EQUIPMENT CODE

: TNL/CPP/ACC/OLS /006

EQUIPMENT DETAILS

: ACD Machine Control

DATE

DESCRIPTION OF THE WORK DONE

01.09.2013

Switch function was checked and found oil level was low. After oil top up .

02.10.2013

Found float fully jammed condition.Switch cleaned.Now noraml

24.10.2014

ACC- 6 oil level Switch was checked and Found normal

10.01.2015

ACC fan - 6 oil level switches was inspected. Found normal

29.06.2015

ACC fan -6 oil level switches was inspected and found normal

28.09.2015

switch was cleaned and inspection work done

26.01.2016

switch was cleaned and inspection work done

27.02.2016

switch was cleaned and inspection work done

TYPE OF WORK : PM - Preventive maint.

CBM- Condition based maint. SD - Shutdown maint. BD - Break down maint.

DATE

DESCRIPTION OF THE WORK DONE

TYPE OF WORK : PM - Preventive maint.

CBM- Condition based maint. SD - Shutdown maint. BD - Break down maint.

RVICES PRIVATE LIMITED.

SYAN NEC LIMITED.GUMMIDIPOONDI - 601201.

MENT HISTORY CARD


FORMET NO : 001

TYPE OF WORK

MANNING

SPARES CONSUMED

CBM

NIL

CBM

NIL

CBM

NIL

SD

NIL

CBM

NIL

SD

NIL

SD

NIL

SD

NIL

INCHARGE SIGNATURE

int. BD - Break down maint. OTH : Other maint.

TYPE OF WORK

MANNING

SPARES CONSUMED

INCHARGE SIGNATURE

int. BD - Break down maint. OTH : Other maint.

ENMAS O & M SERVICES PRIVA

2 * 35 MW POWER PLANT , TULSYAN NEC LIMITED.GUM


EQUIPMENT HISTORY CARD
AREA
NAME OF THE EQUIPMENT

: ACC
: Oil level switch

EQUIPMENT CODE

: TNL/CPP/ACC/OLS /007

EQUIPMENT DETAILS

: ACD Machine Control

DATE

DESCRIPTION OF THE WORK DONE

02.10.2013

found float fully jammed condition.Switch cleaned & found normal

06.11.2013

Found oil level was low. After top up it was normal.

13.03.2014

Oil level switch was cleaned and now fan is running normally.

21.04.2014

Oil level switch removed then, inserting tube hole dia was increased .

12.05.2014

Oil was below the normal level and viscosity was bad, so new oil was topup

01.05.2014

Level Switch cleaned .

10.01.2015

ACC fan - 7 oil level switches was inspected. And found normal

12.02.2015

ACC fan - 7 oil level switches was inspected. And found normal

28.06.2015

ACC fan - 7 oil level switches was inspected. And found normal

28.09.2015

switch was cleaned and inspection work done

26.01.2016

switch was cleaned and inspection work done

27.02.2016

switch was cleaned and inspection work done

TYPE OF WORK : PM - Preventive maint.

CBM- Condition based maint. SD - Shutdown maint. BD - Break down maint.

DATE

DESCRIPTION OF THE WORK DONE

TYPE OF WORK : PM - Preventive maint.

CBM- Condition based maint. SD - Shutdown maint. BD - Break down maint.

RVICES PRIVATE LIMITED.

SYAN NEC LIMITED.GUMMIDIPOONDI - 601201.

MENT HISTORY CARD


FORMET NO : 001

TYPE OF WORK

MANNING

SPARES CONSUMED

CBM

NIL

CBM

NIL

CBM

NIL

CBM

NIL

CBM

NIL

CBM

NIL

SD

NIL

CBM

NIL

CBM

NIL

SD

NIL

SD

NIL

SD

NIL

INCHARGE SIGNATURE

int. BD - Break down maint. OTH : Other maint.

TYPE OF WORK

MANNING

SPARES CONSUMED

INCHARGE SIGNATURE

int. BD - Break down maint. OTH : Other maint.

ENMAS O & M SERVICES PRIVA

2 * 35 MW POWER PLANT , TULSYAN NEC LIMITED.GUM


EQUIPMENT HISTORY CARD
AREA
NAME OF THE EQUIPMENT

: ACC
: Oil level switch

EQUIPMENT CODE

: TNL/CPP/ACC/OLS /008

EQUIPMENT DETAILS

DATE

ACD Machine Control

DESCRIPTION OF THE WORK DONE

16.08.2014

Gear box oil level switch was checked and oil was top up by Mech team

21.10.2014

ACC- 8 oil level Switch was checked and Found normal

10.11.2014

ACC fan 4 oil level switch is interchanged to ACC fan 8.

28.06.2015

ACC- 8 oil level Switch was checked . Found normal

28.09.2015

switch was cleaned and inspection work done

22.10.2015

switch was cleaned and inspection work done

26.01.2016

switch was cleaned and inspection work done

27.02.2016

switch was cleaned and inspection work done

TYPE OF WORK : PM - Preventive maint.

CBM- Condition based maint. SD - Shutdown maint. BD - Break down maint.

DATE

DESCRIPTION OF THE WORK DONE

TYPE OF WORK : PM - Preventive maint.

CBM- Condition based maint. SD - Shutdown maint. BD - Break down maint.

RVICES PRIVATE LIMITED.

SYAN NEC LIMITED.GUMMIDIPOONDI - 601201.

MENT HISTORY CARD


FORMET NO : 001

TYPE OF WORK

MANNING

SPARES CONSUMED

CBM

NIL

CBM

NIL

CBM

NIL

CBM

NIL

SD

NIL

CBM

NIL

SD

NIL

SD

NIL

INCHARGE SIGNATURE

int. BD - Break down maint. OTH : Other maint.

TYPE OF WORK

MANNING

SPARES CONSUMED

INCHARGE SIGNATURE

int. BD - Break down maint. OTH : Other maint.

ENMAS O & M SERVICES PRIVA

2 * 35 MW POWER PLANT , TULSYAN NEC LIMITED.GUM


EQUIPMENT HISTORY CARD
AREA
NAME OF THE EQUIPMENT

: ACC
: Vibration switch

EQUIPMENT CODE

: TNL/CPP/ACC/VS /008

EQUIPMENT DETAILS

DATE

ACD Machine Control

DESCRIPTION OF THE WORK DONE

13.01.2015

Vibration switch was replaced new one

29.03.2015

Vibration switch was checked and found normal

15.05.2015

Vibration switch was checked and found normal

17.07.2015

Vibration switch was checked and found normal

28.09.2015

Vibration switch was checked and found normal

27.02.2016

Vibration switch was checked and found normal

TYPE OF WORK : PM - Preventive maint.

CBM- Condition based maint. SD - Shutdown maint. BD - Break down maint.

DATE

DESCRIPTION OF THE WORK DONE

TYPE OF WORK : PM - Preventive maint.

CBM- Condition based maint. SD - Shutdown maint. BD - Break down maint.

RVICES PRIVATE LIMITED.

SYAN NEC LIMITED.GUMMIDIPOONDI - 601201.

MENT HISTORY CARD


FORMET NO : 001

TYPE OF WORK

MANNING

SPARES CONSUMED

CBM

Vibration switch - 01 no

SD

NIL

SD

NIL

SD

NIL

SD

NIL

SD

NIL

INCHARGE SIGNATURE

int. BD - Break down maint. OTH : Other maint.

TYPE OF WORK

MANNING

SPARES CONSUMED

INCHARGE SIGNATURE

int. BD - Break down maint. OTH : Other maint.

ENMAS O & M SERVICES PRIVA

2 * 35 MW POWER PLANT , TULSYAN NEC LIMITED.GUM


EQUIPMENT HISTORY CARD
AREA
NAME OF THE EQUIPMENT

: ACC
: Vibration switch

EQUIPMENT CODE

: TNL/CPP/ACC/VS /007

EQUIPMENT DETAILS

DATE

ACD Machine Control

DESCRIPTION OF THE WORK DONE

29.03.2015

Vibration switch was checked and found normal

15.05.2015

Vibration switch was checked and found normal

17.07.2015

Vibration switch was checked and found normal

28.09.2015

Vibration switch was checked and found normal

27.02.2016

Vibration switch was checked and found normal

TYPE OF WORK : PM - Preventive maint.

CBM- Condition based maint. SD - Shutdown maint. BD - Break down maint.

DATE

DESCRIPTION OF THE WORK DONE

TYPE OF WORK : PM - Preventive maint.

CBM- Condition based maint. SD - Shutdown maint. BD - Break down maint.

RVICES PRIVATE LIMITED.

SYAN NEC LIMITED.GUMMIDIPOONDI - 601201.

MENT HISTORY CARD


FORMET NO : 001

TYPE OF WORK

MANNING

SPARES CONSUMED

SD

NIL

SD

NIL

SD

NIL

SD

NIL

SD

NIL

INCHARGE SIGNATURE

int. BD - Break down maint. OTH : Other maint.

TYPE OF WORK

MANNING

SPARES CONSUMED

INCHARGE SIGNATURE

int. BD - Break down maint. OTH : Other maint.

ENMAS O & M SERVICES PRIVA

2 * 35 MW POWER PLANT , TULSYAN NEC LIMITED.GUM


EQUIPMENT HISTORY CARD
AREA
NAME OF THE EQUIPMENT

: ACC
: Vibration switch

EQUIPMENT CODE

: TNL/CPP/ACC/VS /006

EQUIPMENT DETAILS

DATE

ACD Machine Control

DESCRIPTION OF THE WORK DONE

29.03.2015

Vibration switch was checked and found normal

15.05.2015

Vibration switch was checked and found normal

17.07.2015

Vibration switch was checked and found normal

28.09.2015

Vibration switch was checked and found normal

27.02.2016

Vibration switch was checked and found normal

TYPE OF WORK : PM - Preventive maint.

CBM- Condition based maint. SD - Shutdown maint. BD - Break down maint.

DATE

DESCRIPTION OF THE WORK DONE

TYPE OF WORK : PM - Preventive maint.

CBM- Condition based maint. SD - Shutdown maint. BD - Break down maint.

RVICES PRIVATE LIMITED.

SYAN NEC LIMITED.GUMMIDIPOONDI - 601201.

MENT HISTORY CARD


FORMET NO : 001

TYPE OF WORK

MANNING

SPARES CONSUMED

SD

NIL

SD

NIL

SD

NIL

SD

NIL

SD

NIL

INCHARGE SIGNATURE

int. BD - Break down maint. OTH : Other maint.

TYPE OF WORK

MANNING

SPARES CONSUMED

INCHARGE SIGNATURE

int. BD - Break down maint. OTH : Other maint.

ENMAS O & M SERVICES PRIVA

2 * 35 MW POWER PLANT , TULSYAN NEC LIMITED.GUM


EQUIPMENT HISTORY CARD
AREA
NAME OF THE EQUIPMENT

: ACC
: Vibration switch

EQUIPMENT CODE

: TNL/CPP/ACC/VS /005

EQUIPMENT DETAILS

DATE

ACD Machine Control

DESCRIPTION OF THE WORK DONE

29.03.2015

Vibration switch was checked and found normal .

15.05.2015

Vibration switch was checked and found normal

17.07.2015

Vibration switch was checked and found normal

28.09.2015

Vibration switch was checked and found normal

27.02.2016

Vibration switch was checked and found normal

TYPE OF WORK : PM - Preventive maint.

CBM- Condition based maint. SD - Shutdown maint. BD - Break down maint.

DATE

DESCRIPTION OF THE WORK DONE

TYPE OF WORK : PM - Preventive maint.

CBM- Condition based maint. SD - Shutdown maint. BD - Break down maint.

RVICES PRIVATE LIMITED.

SYAN NEC LIMITED.GUMMIDIPOONDI - 601201.

MENT HISTORY CARD


FORMET NO : 001

TYPE OF WORK

MANNING

SPARES CONSUMED

SD

NIL

SD

NIL

SD

NIL

SD

NIL

SD

NIL

INCHARGE SIGNATURE

int. BD - Break down maint. OTH : Other maint.

TYPE OF WORK

MANNING

SPARES CONSUMED

INCHARGE SIGNATURE

int. BD - Break down maint. OTH : Other maint.

ENMAS O & M SERVICES PRIVA

2 * 35 MW POWER PLANT , TULSYAN NEC LIMITED.GUM


EQUIPMENT HISTORY CARD
AREA
NAME OF THE EQUIPMENT

: ACC
: Vibration switch

EQUIPMENT CODE

: TNL/CPP/ACC/VS /004

EQUIPMENT DETAILS

DATE

ACD Machine Control

DESCRIPTION OF THE WORK DONE

29.03.2015

Vibration switch was checked and found normal

15.05.2015

Vibration switch was checked and found normal

17.07.2015

Vibration switch was checked and found normal

28.09.2015

Vibration switch was checked and found normal

26.02.2016

ACC fan - 04 Capacitance type level Switch r was replaced

TYPE OF WORK : PM - Preventive maint.

CBM- Condition based maint. SD - Shutdown maint. BD - Break down maint.

DATE

DESCRIPTION OF THE WORK DONE

TYPE OF WORK : PM - Preventive maint.

CBM- Condition based maint. SD - Shutdown maint. BD - Break down maint.

RVICES PRIVATE LIMITED.

SYAN NEC LIMITED.GUMMIDIPOONDI - 601201.

MENT HISTORY CARD


FORMET NO : 001

TYPE OF WORK

MANNING

SPARES CONSUMED

SD

NIL

SD

NIL

SD

NIL

SD

NIL

SD

Oil level switch - 01 no

INCHARGE SIGNATURE

int. BD - Break down maint. OTH : Other maint.

TYPE OF WORK

MANNING

SPARES CONSUMED

INCHARGE SIGNATURE

int. BD - Break down maint. OTH : Other maint.

ENMAS O & M SERVICES PRIVA

2 * 35 MW POWER PLANT , TULSYAN NEC LIMITED.GUM


EQUIPMENT HISTORY CARD
AREA
NAME OF THE EQUIPMENT

: ACC
: Vibration switch

EQUIPMENT CODE

: TNL/CPP/ACC/VS /003

EQUIPMENT DETAILS

DATE

ACD Machine Control

DESCRIPTION OF THE WORK DONE

29.03.2015

Vibration switch was checked and found normal

15.05.2015

Vibration switch was checked and found normal

17.07.2015

Vibration switch was checked and found normal

28.09.2015

Vibration switch was checked and found normal

28.09.2016

Vibration switch was checked and found normal

27.02.2016

Vibration switch was checked and found normal

TYPE OF WORK : PM - Preventive maint.

CBM- Condition based maint. SD - Shutdown maint. BD - Break down maint.

DATE

DESCRIPTION OF THE WORK DONE

TYPE OF WORK : PM - Preventive maint.

CBM- Condition based maint. SD - Shutdown maint. BD - Break down maint.

RVICES PRIVATE LIMITED.

SYAN NEC LIMITED.GUMMIDIPOONDI - 601201.

MENT HISTORY CARD


FORMET NO : 001

TYPE OF WORK

MANNING

SPARES CONSUMED

SD

NIL

SD

NIL

SD

NIL

SD

NIL

PM

NIL

SD

NIL

INCHARGE SIGNATURE

int. BD - Break down maint. OTH : Other maint.

TYPE OF WORK

MANNING

SPARES CONSUMED

INCHARGE SIGNATURE

int. BD - Break down maint. OTH : Other maint.

ENMAS O & M SERVICES PRIVA

2 * 35 MW POWER PLANT , TULSYAN NEC LIMITED.GUM


EQUIPMENT HISTORY CARD
AREA
NAME OF THE EQUIPMENT

: ACC
: Vibration switch

EQUIPMENT CODE

: TNL/CPP/ACC/VS /002

EQUIPMENT DETAILS

DATE

ACD Machine Control

DESCRIPTION OF THE WORK DONE

29.03.2015

Vibration switch was checked and found normal

15.05.2015

Vibration switch was checked and found normal

17.07.2015

Vibration switch was checked and found normal

28.09.2015

Vibration switch was checked and found normal

30.11.2015

Vibration switch was checked and found normal

27.02.2016

Vibration switch was checked and found normal

TYPE OF WORK : PM - Preventive maint.

CBM- Condition based maint. SD - Shutdown maint. BD - Break down maint.

DATE

DESCRIPTION OF THE WORK DONE

TYPE OF WORK : PM - Preventive maint.

CBM- Condition based maint. SD - Shutdown maint. BD - Break down maint.

RVICES PRIVATE LIMITED.

SYAN NEC LIMITED.GUMMIDIPOONDI - 601201.

MENT HISTORY CARD


FORMET NO : 001

TYPE OF WORK

MANNING

SPARES CONSUMED

SD

NIL

SD

NIL

SD

NIL

SD

NIL

CBM

NIL

SD

NIL

INCHARGE SIGNATURE

int. BD - Break down maint. OTH : Other maint.

TYPE OF WORK

MANNING

SPARES CONSUMED

INCHARGE SIGNATURE

int. BD - Break down maint. OTH : Other maint.

ENMAS O & M SERVICES PRIVA

2 * 35 MW POWER PLANT , TULSYAN NEC LIMITED.GUM


EQUIPMENT HISTORY CARD
AREA
NAME OF THE EQUIPMENT

: ACC
: Vibration switch

EQUIPMENT CODE

: TNL/CPP/CT/OLS /001

EQUIPMENT DETAILS

DATE

ACD Machine Control

DESCRIPTION OF THE WORK DONE

29.03.2015

switch was checked and found normal

15.05.2015

switch was checked and found normal

17.07.2015

switch was checked and found normal

28.09.2015

switch was checked and found normal

27.02.2016

switch was checked and found normal

TYPE OF WORK : PM - Preventive maint.

CBM- Condition based maint. SD - Shutdown maint. BD - Break down maint.

DATE

DESCRIPTION OF THE WORK DONE

TYPE OF WORK : PM - Preventive maint.

CBM- Condition based maint. SD - Shutdown maint. BD - Break down maint.

RVICES PRIVATE LIMITED.

SYAN NEC LIMITED.GUMMIDIPOONDI - 601201.

MENT HISTORY CARD


FORMET NO : 001

TYPE OF WORK

MANNING

SPARES CONSUMED

SD

NIL

SD

NIL

SD

NIL

SD

NIL

SD

NIL

INCHARGE SIGNATURE

int. BD - Break down maint. OTH : Other maint.

TYPE OF WORK

MANNING

SPARES CONSUMED

INCHARGE SIGNATURE

int. BD - Break down maint. OTH : Other maint.

ENMAS O & M SERVICES PRIVA

2 * 35 MW POWER PLANT , TULSYAN NEC LIMITED.GUM


EQUIPMENT HISTORY CARD
AREA
NAME OF THE EQUIPMENT

: COOLING TOWER
: Oil level switch

EQUIPMENT CODE

: TNL/CPP/CT/OLS /002

EQUIPMENT DETAILS

: Pahar pur cooling tower Ltd

DATE

DESCRIPTION OF THE WORK DONE

12.12.2014

CT FAN vibration switches was checked

18.12.2014

CT FAN oil level switch cleaning work done

18.01.2015

CT FAN - 2 Oil level switch, vibration switch was checked

28.01.2015

CT FAN - 2 Oil level switch, vibration switch was checked

04.02.2015

CT FAN - 2 Oil level switch was checked

17.08.2015

CT FAN - 2 Oil level switch was checked

17.09.2015

CT FAN - 2 Oil level switch was checked

18.03.2016

CT FAN - 2 Oil level switch was checked

TYPE OF WORK : PM - Preventive maint.

CBM- Condition based maint. SD - Shutdown maint. BD - Break down maint.

DATE

DESCRIPTION OF THE WORK DONE

TYPE OF WORK : PM - Preventive maint.

CBM- Condition based maint. SD - Shutdown maint. BD - Break down maint.

RVICES PRIVATE LIMITED.

SYAN NEC LIMITED.GUMMIDIPOONDI - 601201.

MENT HISTORY CARD


FORMET NO : 001

TYPE OF WORK

MANNING

SPARES CONSUMED

SD

NIL

SD

NIL

SD

NIL

SD

NIL

SD

NIL

PM

NIL

PM

NIL

PM

NIL

INCHARGE SIGNATURE

int. BD - Break down maint. OTH : Other maint.

TYPE OF WORK

MANNING

SPARES CONSUMED

INCHARGE SIGNATURE

int. BD - Break down maint. OTH : Other maint.

ENMAS O & M SERVICES PRIVA

2 * 35 MW POWER PLANT , TULSYAN NEC LIMITED.GUM


EQUIPMENT HISTORY CARD
AREA
NAME OF THE EQUIPMENT

: COOLING TOWER
: Oil level switch

EQUIPMENT CODE

: TNL/CPP/CT/OLS /001

EQUIPMENT DETAILS

DATE

Pahar pur cooling tower Ltd

DESCRIPTION OF THE WORK DONE

26.06.2015

CT FAN - 1 Oil level switch was checked

28.02.2016

CT FAN - 1 Oil level switch was checked

08.03.2016

CT FAN - 1 Oil level switch was checked

TYPE OF WORK : PM - Preventive maint.

CBM- Condition based maint. SD - Shutdown maint. BD - Break down maint.

DATE

DESCRIPTION OF THE WORK DONE

TYPE OF WORK : PM - Preventive maint.

CBM- Condition based maint. SD - Shutdown maint. BD - Break down maint.

RVICES PRIVATE LIMITED.

SYAN NEC LIMITED.GUMMIDIPOONDI - 601201.

MENT HISTORY CARD


FORMET NO : 001

TYPE OF WORK

MANNING

SPARES CONSUMED

SD

NIL

CBM

NIL

PM

NIL

INCHARGE SIGNATURE

int. BD - Break down maint. OTH : Other maint.

TYPE OF WORK

MANNING

SPARES CONSUMED

INCHARGE SIGNATURE

int. BD - Break down maint. OTH : Other maint.

ENMAS O & M SERVICES PRIVA

2 * 35 MW POWER PLANT , TULSYAN NEC LIMITED.GUM


EQUIPMENT HISTORY CARD
AREA
NAME OF THE EQUIPMENT

: COOLING TOWER
: Oil level switch

EQUIPMENT CODE

: TNL/CPP/CT/OLS /003

EQUIPMENT DETAILS

DATE

Pahar pur cooling tower Ltd

DESCRIPTION OF THE WORK DONE

15.11.2013

Vibration switch was cleaned and found normal

03.05.2014

Vibration switch was cleaned and found normal

29.11.2014

CT fan - 3 Vibration switch de dusting work done

28.05.2015

CT Fan -3 vibration and oil level switch was cleaned

26.06.2015

CT FAN - 3 Oil level limit switch was replaced

28.08.2015

CT fan - 3 oil level switch was checked

08.09.2015

CT fan - 3 oil level switch was checked

06.11.2015

CT fan - 3 oil level switch was checked

28.12.2015

CT fan - 3 oil level switch was checked

21.01.2016

CT fan - 3 oil level switch was checked

02.03.2016

CT fan - 3 oil level switch was checked

TYPE OF WORK : PM - Preventive maint.

CBM- Condition based maint. SD - Shutdown maint. BD - Break down maint.

DATE

DESCRIPTION OF THE WORK DONE

TYPE OF WORK : PM - Preventive maint.

CBM- Condition based maint. SD - Shutdown maint. BD - Break down maint.

RVICES PRIVATE LIMITED.

SYAN NEC LIMITED.GUMMIDIPOONDI - 601201.

MENT HISTORY CARD


FORMET NO : 003

TYPE OF WORK

MANNING

SPARES CONSUMED

CBM

NIL

CBM

NIL

CBM

NIL

CBM

NIL

CBM

Limit switch - 01 No

PM

NIL

PM

NIL

PM

NIL

PM

NIL

PM

NIL

PM

NIL

INCHARGE SIGNATURE

int. BD - Break down maint. OTH : Other maint.

TYPE OF WORK

MANNING

SPARES CONSUMED

INCHARGE SIGNATURE

int. BD - Break down maint. OTH : Other maint.

ENMAS O & M SERVICES PRIVA

2 * 35 MW POWER PLANT , TULSYAN NEC LIMITED.GUM


EQUIPMENT HISTORY CARD
AREA
NAME OF THE EQUIPMENT

: COOLING TOWER
: Vibration switch

EQUIPMENT CODE

: TNL/CPP/CT/VS /002

EQUIPMENT DETAILS

: Pahar pur cooling tower Ltd

DATE

DESCRIPTION OF THE WORK DONE

12.12.2014

CT FAN vibration switches was checked

18.12.2014

CT FAN oil level switch cleaning work done

18.01.2015

CT FAN - 2 Oil level switch, vibration switch was checked

28.01.2015

CT FAN - 2 Oil level switch, vibration switch was checked

04.02.2015

CT FAN - 2 Oil level switch was checked

28.09.2015

Vibration switch was checked and found normal

17.10.2015

Vibration switch was checked and found normal

17.02.2016

Vibration switch was checked and found normal

27.02.2016

Vibration switch was checked and found normal

18.03.2016

CT FAN - 2 vibration switch was checked

TYPE OF WORK : PM - Preventive maint.

CBM- Condition based maint. SD - Shutdown maint. BD - Break down maint.

DATE

DESCRIPTION OF THE WORK DONE

TYPE OF WORK : PM - Preventive maint.

CBM- Condition based maint. SD - Shutdown maint. BD - Break down maint.

RVICES PRIVATE LIMITED.

SYAN NEC LIMITED.GUMMIDIPOONDI - 601201.

MENT HISTORY CARD


FORMET NO : 001

TYPE OF WORK

MANNING

SPARES CONSUMED

CBM

NIL

CBM

NIL

CBM

NIL

CBM

NIL

CBM

NIL

SD

NIL

PM

NIL

PM

NIL

PM

NIL

PM

NIL

INCHARGE SIGNATURE

int. BD - Break down maint. OTH : Other maint.

TYPE OF WORK

MANNING

SPARES CONSUMED

INCHARGE SIGNATURE

int. BD - Break down maint. OTH : Other maint.

ENMAS O & M SERVICES PRIVA

2 * 35 MW POWER PLANT , TULSYAN NEC LIMITED.GUM


EQUIPMENT HISTORY CARD
AREA
NAME OF THE EQUIPMENT

: COOLING TOWER
: Vibration switch

EQUIPMENT CODE

: TNL/CPP/CT/VS /001

EQUIPMENT DETAILS

: Pahar pur cooling tower Ltd

DATE

DESCRIPTION OF THE WORK DONE

26.06.2015

CT FAN - 1 Oil level switch was checked

08.03.2016

CT FAN - 1 Oil level switch was checked

TYPE OF WORK : PM - Preventive maint.

CBM- Condition based maint. SD - Shutdown maint. BD - Break down maint.

DATE

DESCRIPTION OF THE WORK DONE

TYPE OF WORK : PM - Preventive maint.

CBM- Condition based maint. SD - Shutdown maint. BD - Break down maint.

RVICES PRIVATE LIMITED.

SYAN NEC LIMITED.GUMMIDIPOONDI - 601201.

MENT HISTORY CARD


FORMET NO : 001

TYPE OF WORK

MANNING

CBM

PM

SPARES CONSUMED

INCHARGE SIGNATURE

int. BD - Break down maint. OTH : Other maint.

TYPE OF WORK

MANNING

SPARES CONSUMED

INCHARGE SIGNATURE

int. BD - Break down maint. OTH : Other maint.

ENMAS O & M SERVICES PRIVA

2 * 35 MW POWER PLANT , TULSYAN NEC LIMITED.GUM


EQUIPMENT HISTORY CARD
AREA
NAME OF THE EQUIPMENT

: COOLING TOWER
: Vibration switch

EQUIPMENT CODE

: TNL/CPP/CT/VS /003

EQUIPMENT DETAILS

: Pahar pur cooling tower Ltd

DATE

DESCRIPTION OF THE WORK DONE

15.11.2013

Vibration switch was cleaned and found normal

03.05.2014

Vibration switch was cleaned and found normal

29.11.2014

CT fan - 3 Vibration switch de dusting work done

28.05.2015
02.03.2016

CT Fan -3 vibration and oil level switch was cleaned


Vibration switch was cleaned and found normal

TYPE OF WORK : PM - Preventive maint.

CBM- Condition based maint. SD - Shutdown maint. BD - Break down maint.

DATE

DESCRIPTION OF THE WORK DONE

TYPE OF WORK : PM - Preventive maint.

CBM- Condition based maint. SD - Shutdown maint. BD - Break down maint.

RVICES PRIVATE LIMITED.

SYAN NEC LIMITED.GUMMIDIPOONDI - 601201.

MENT HISTORY CARD


FORMET NO : 001

TYPE OF WORK

MANNING

SPARES CONSUMED

CBM

NIL

CBM

NIL

CBM

NIL

CBM

NIL

CBM

NIL

INCHARGE SIGNATURE

int. BD - Break down maint. OTH : Other maint.

TYPE OF WORK

MANNING

SPARES CONSUMED

INCHARGE SIGNATURE

int. BD - Break down maint. OTH : Other maint.