Sie sind auf Seite 1von 33

Fri Oct 14 17:14:31 2016 Version: 7.

22 Settings (Enabled Features)

PAGE 1

QUICK CONNECT
QUICK CONNECT DEVICE
DEVICE DEFINITION
ORDER CODE: M60-J03-VKH-F8M-H5C-M6E-PXX
VERSION: 6.0X
DESCRIPTION: (NONE)
INTERFACE: COM2: 19200 N 8 1
PRODUCT SETUP
SECURITY
Command Password
Setting Password
Command Password Access Timeout
Setting Password Access Timeout
Invalid Password Attempts
Password Lockout Duration
Password Access Events
Local Setting Authorized
Remote Setting Authorized
Access Authorized Timeout
DISPLAY PROPERTIES
Flash Message Time
Default Message Timeout
Default Message Intensity (VFD Only)
Screen Saver Feature (LCD Only)
Screen Saver Wait Time (LCD Only)
Current Cutoff Level
Voltage Cutoff Level
COMMUNICATIONS
SERIAL PORTS
COM2 Selection
RS485 Com2 Baud Rate
RS485 Com2 Parity
RS485 Com2 Response Min Time

0
0
5 min
30 min
3
5 min
Disabled
ON
ON
30 min
1.0 s
300 s
25 %
Disabled
30 min
0.020 pu
1.0 V

RS485
19200
None
0 ms

NETWORK
IP Address
IP Subnet Mask
Gateway IP Address
Ethernet Operation Mode
OSI Network Address (NSAP)

172. 18. 9. 6
255.255.252. 0
172. 18. 9. 20
Full-Duplex
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00

MODBUS PROTOCOL
Modbus Slave Address
Modbus TCP Port Number

1
502

IEC 61850
GSSE / GOOSE CONFIGURATION
TRANSMISSION
GENERAL
Default GSSE/GOOSE Update Time

60 s

GSSE
Function
ID
Destination MAC

Enabled
GSSEOut
00 00 00 00 00 00

SERVER CONFIGURATION
IEDName
Logical Device Instance
MMS TCP Port Number
LPHD DC PhyNam location

IEDName
LDInst
102
Location

MMXU DEADBANDS
MMXU1: TotW Deadband
MMXU1: TotVAr Deadband
MMXU1: TotVA Deadband
MMXU1: TotPF Deadband
MMXU1: Hz Deadband
MMXU1: PPV phsAB Deadband
MMXU1: PPV phsBC Deadband
MMXU1: PPV phsCA Deadband
MMXU1: PhV phsA Deadband
MMXU1: PhV phsB Deadband
MMXU1: PhV phsC Deadband

10.000 %
10.000 %
10.000 %
10.000 %
10.000 %
10.000 %
10.000 %
10.000 %
10.000 %
10.000 %
10.000 %

Fri Oct 14 17:14:31 2016 Version: 7.22 Settings (Enabled Features)

PAGE 2

QUICK CONNECT
QUICK CONNECT DEVICE
DEVICE DEFINITION
ORDER CODE: M60-J03-VKH-F8M-H5C-M6E-PXX
VERSION: 6.0X
DESCRIPTION: (NONE)
INTERFACE: COM2: 19200 N 8 1
MMXU DEADBANDS (continued from last page)
MMXU1: A phsA Deadband
MMXU1: A phsB Deadband
MMXU1: A phsC Deadband
MMXU1: A neut Deadband
MMXU1: W phsA Deadband
MMXU1: W phsB Deadband
MMXU1: W phsC Deadband
MMXU1: VAr phsA Deadband
MMXU1: VAr phsB Deadband
MMXU1: VAr phsC Deadband
MMXU1: VA phsA Deadband
MMXU1: VA phsB Deadband
MMXU1: VA phsC Deadband
MMXU1: PF phsA Deadband
MMXU1: PF phsB Deadband
MMXU1: PF phsC Deadband
MMXU2: TotW Deadband
MMXU2: TotVAr Deadband
MMXU2: TotVA Deadband
MMXU2: TotPF Deadband
MMXU2: Hz Deadband
MMXU2: PPV phsAB Deadband
MMXU2: PPV phsBC Deadband
MMXU2: PPV phsCA Deadband
MMXU2: PhV phsA Deadband
MMXU2: PhV phsB Deadband
MMXU2: PhV phsC Deadband
MMXU2: A phsA Deadband
MMXU2: A phsB Deadband
MMXU2: A phsC Deadband
MMXU2: A neut Deadband
MMXU2: W phsA Deadband
MMXU2: W phsB Deadband
MMXU2: W phsC Deadband
MMXU2: VAr phsA Deadband
MMXU2: VAr phsB Deadband
MMXU2: VAr phsC Deadband
MMXU2: VA phsA Deadband
MMXU2: VA phsB Deadband
MMXU2: VA phsC Deadband
MMXU2: PF phsA Deadband
MMXU2: PF phsB Deadband
MMXU2: PF phsC Deadband

10.000 %
10.000 %
10.000 %
10.000 %
10.000 %
10.000 %
10.000 %
10.000 %
10.000 %
10.000 %
10.000 %
10.000 %
10.000 %
10.000 %
10.000 %
10.000 %
10.000 %
10.000 %
10.000 %
10.000 %
10.000 %
10.000 %
10.000 %
10.000 %
10.000 %
10.000 %
10.000 %
10.000 %
10.000 %
10.000 %
10.000 %
10.000 %
10.000 %
10.000 %
10.000 %
10.000 %
10.000 %
10.000 %
10.000 %
10.000 %
10.000 %
10.000 %
10.000 %

GGIO1 STATUS CONFIGURATION


Number of Status Points

GGIO2 CONTROL CONFIGURATION


SPCSO 1 ctlModel
SPCSO 2 ctlModel
SPCSO 3 ctlModel
SPCSO 4 ctlModel
SPCSO 5 ctlModel
SPCSO 6 ctlModel
SPCSO 7 ctlModel
SPCSO 8 ctlModel
SPCSO 9 ctlModel
SPCSO 10 ctlModel
SPCSO 11 ctlModel
SPCSO 12 ctlModel
SPCSO 13 ctlModel
SPCSO 14 ctlModel
SPCSO 15 ctlModel
SPCSO 16 ctlModel
SPCSO 17 ctlModel
SPCSO 18 ctlModel
SPCSO 19 ctlModel
SPCSO 20 ctlModel

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Fri Oct 14 17:14:31 2016 Version: 7.22 Settings (Enabled Features)

PAGE 3

QUICK CONNECT
QUICK CONNECT DEVICE
DEVICE DEFINITION
ORDER CODE: M60-J03-VKH-F8M-H5C-M6E-PXX
VERSION: 6.0X
DESCRIPTION: (NONE)
INTERFACE: COM2: 19200 N 8 1
GGIO2 CONTROL CONFIGURATION (continued from last page)
SPCSO 21 ctlModel
SPCSO 22 ctlModel
SPCSO 23 ctlModel
SPCSO 24 ctlModel
SPCSO 25 ctlModel
SPCSO 26 ctlModel
SPCSO 27 ctlModel
SPCSO 28 ctlModel
SPCSO 29 ctlModel
SPCSO 30 ctlModel
SPCSO 31 ctlModel
SPCSO 32 ctlModel
SPCSO 33 ctlModel
SPCSO 34 ctlModel
SPCSO 35 ctlModel
SPCSO 36 ctlModel
SPCSO 37 ctlModel
SPCSO 38 ctlModel
SPCSO 39 ctlModel
SPCSO 40 ctlModel
SPCSO 41 ctlModel
SPCSO 42 ctlModel
SPCSO 43 ctlModel
SPCSO 44 ctlModel
SPCSO 45 ctlModel
SPCSO 46 ctlModel
SPCSO 47 ctlModel
SPCSO 48 ctlModel
SPCSO 49 ctlModel
SPCSO 50 ctlModel
SPCSO 51 ctlModel
SPCSO 52 ctlModel
SPCSO 53 ctlModel
SPCSO 54 ctlModel
SPCSO 55 ctlModel
SPCSO 56 ctlModel
SPCSO 57 ctlModel
SPCSO 58 ctlModel
SPCSO 59 ctlModel
SPCSO 60 ctlModel
SPCSO 61 ctlModel
SPCSO 62 ctlModel
SPCSO 63 ctlModel
SPCSO 64 ctlModel

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

GGIO4 ANALOG CONFIGURATION


IEC61850 GGIO4 Analogs
IEC61850 GGIO4 Analog 1 Value
IEC61850 GGIO4 Analog 1 db
IEC61850 GGIO4 Analog 1 min
IEC61850 GGIO4 Analog 1 max
IEC61850 GGIO4 Analog 2 Value
IEC61850 GGIO4 Analog 2 db
IEC61850 GGIO4 Analog 2 min
IEC61850 GGIO4 Analog 2 max
IEC61850 GGIO4 Analog 3 Value
IEC61850 GGIO4 Analog 3 db
IEC61850 GGIO4 Analog 3 min
IEC61850 GGIO4 Analog 3 max
IEC61850 GGIO4 Analog 4 Value
IEC61850 GGIO4 Analog 4 db
IEC61850 GGIO4 Analog 4 min
IEC61850 GGIO4 Analog 4 max
IEC61850 GGIO4 Analog 5 Value
IEC61850 GGIO4 Analog 5 db
IEC61850 GGIO4 Analog 5 min
IEC61850 GGIO4 Analog 5 max
IEC61850 GGIO4 Analog 6 Value

4
OFF
100.000 %
0.000
1000000.000
OFF
100.000 %
0.000
1000000.000
OFF
100.000 %
0.000
1000000.000
OFF
100.000 %
0.000
1000000.000
OFF
100.000 %
0.000
1000000.000
OFF

Fri Oct 14 17:14:31 2016 Version: 7.22 Settings (Enabled Features)

PAGE 4

QUICK CONNECT
QUICK CONNECT DEVICE
DEVICE DEFINITION
ORDER CODE: M60-J03-VKH-F8M-H5C-M6E-PXX
VERSION: 6.0X
DESCRIPTION: (NONE)
INTERFACE: COM2: 19200 N 8 1
GGIO4 ANALOG CONFIGURATION (continued from last page)
IEC61850 GGIO4 Analog 6 db
IEC61850 GGIO4 Analog 6 min
IEC61850 GGIO4 Analog 6 max
IEC61850 GGIO4 Analog 7 Value
IEC61850 GGIO4 Analog 7 db
IEC61850 GGIO4 Analog 7 min
IEC61850 GGIO4 Analog 7 max
IEC61850 GGIO4 Analog 8 Value
IEC61850 GGIO4 Analog 8 db
IEC61850 GGIO4 Analog 8 min
IEC61850 GGIO4 Analog 8 max
IEC61850 GGIO4 Analog 9 Value
IEC61850 GGIO4 Analog 9 db
IEC61850 GGIO4 Analog 9 min
IEC61850 GGIO4 Analog 9 max
IEC61850 GGIO4 Analog 10 Value
IEC61850 GGIO4 Analog 10 db
IEC61850 GGIO4 Analog 10 min
IEC61850 GGIO4 Analog 10 max
IEC61850 GGIO4 Analog 11 Value
IEC61850 GGIO4 Analog 11 db
IEC61850 GGIO4 Analog 11 min
IEC61850 GGIO4 Analog 11 max
IEC61850 GGIO4 Analog 12 Value
IEC61850 GGIO4 Analog 12 db
IEC61850 GGIO4 Analog 12 min
IEC61850 GGIO4 Analog 12 max
IEC61850 GGIO4 Analog 13 Value
IEC61850 GGIO4 Analog 13 db
IEC61850 GGIO4 Analog 13 min
IEC61850 GGIO4 Analog 13 max
IEC61850 GGIO4 Analog 14 Value
IEC61850 GGIO4 Analog 14 db
IEC61850 GGIO4 Analog 14 min
IEC61850 GGIO4 Analog 14 max
IEC61850 GGIO4 Analog 15 Value
IEC61850 GGIO4 Analog 15 db
IEC61850 GGIO4 Analog 15 min
IEC61850 GGIO4 Analog 15 max
IEC61850 GGIO4 Analog 16 Value
IEC61850 GGIO4 Analog 16 db
IEC61850 GGIO4 Analog 16 min
IEC61850 GGIO4 Analog 16 max
IEC61850 GGIO4 Analog 17 Value
IEC61850 GGIO4 Analog 17 db
IEC61850 GGIO4 Analog 17 min
IEC61850 GGIO4 Analog 17 max
IEC61850 GGIO4 Analog 18 Value
IEC61850 GGIO4 Analog 18 db
IEC61850 GGIO4 Analog 18 min
IEC61850 GGIO4 Analog 18 max
IEC61850 GGIO4 Analog 19 Value
IEC61850 GGIO4 Analog 19 db
IEC61850 GGIO4 Analog 19 min
IEC61850 GGIO4 Analog 19 max
IEC61850 GGIO4 Analog 20 Value
IEC61850 GGIO4 Analog 20 db
IEC61850 GGIO4 Analog 20 min
IEC61850 GGIO4 Analog 20 max
IEC61850 GGIO4 Analog 21 Value
IEC61850 GGIO4 Analog 21 db
IEC61850 GGIO4 Analog 21 min
IEC61850 GGIO4 Analog 21 max
IEC61850 GGIO4 Analog 22 Value
IEC61850 GGIO4 Analog 22 db
IEC61850 GGIO4 Analog 22 min
IEC61850 GGIO4 Analog 22 max
IEC61850 GGIO4 Analog 23 Value

100.000 %
0.000
1000000.000
OFF
100.000 %
0.000
1000000.000
OFF
100.000 %
0.000
1000000.000
OFF
100.000 %
0.000
1000000.000
OFF
100.000 %
0.000
1000000.000
OFF
100.000 %
0.000
1000000.000
OFF
100.000 %
0.000
1000000.000
OFF
100.000 %
0.000
1000000.000
OFF
100.000 %
0.000
1000000.000
OFF
100.000 %
0.000
1000000.000
OFF
100.000 %
0.000
1000000.000
OFF
100.000 %
0.000
1000000.000
OFF
100.000 %
0.000
1000000.000
OFF
100.000 %
0.000
1000000.000
OFF
100.000 %
0.000
1000000.000
OFF
100.000 %
0.000
1000000.000
OFF
100.000 %
0.000
1000000.000
OFF

Fri Oct 14 17:14:31 2016 Version: 7.22 Settings (Enabled Features)

PAGE 5

QUICK CONNECT
QUICK CONNECT DEVICE
DEVICE DEFINITION
ORDER CODE: M60-J03-VKH-F8M-H5C-M6E-PXX
VERSION: 6.0X
DESCRIPTION: (NONE)
INTERFACE: COM2: 19200 N 8 1
GGIO4 ANALOG CONFIGURATION (continued from last page)
IEC61850 GGIO4 Analog 23 db
IEC61850 GGIO4 Analog 23 min
IEC61850 GGIO4 Analog 23 max
IEC61850 GGIO4 Analog 24 Value
IEC61850 GGIO4 Analog 24 db
IEC61850 GGIO4 Analog 24 min
IEC61850 GGIO4 Analog 24 max
IEC61850 GGIO4 Analog 25 Value
IEC61850 GGIO4 Analog 25 db
IEC61850 GGIO4 Analog 25 min
IEC61850 GGIO4 Analog 25 max
IEC61850 GGIO4 Analog 26 Value
IEC61850 GGIO4 Analog 26 db
IEC61850 GGIO4 Analog 26 min
IEC61850 GGIO4 Analog 26 max
IEC61850 GGIO4 Analog 27 Value
IEC61850 GGIO4 Analog 27 db
IEC61850 GGIO4 Analog 27 min
IEC61850 GGIO4 Analog 27 max
IEC61850 GGIO4 Analog 28 Value
IEC61850 GGIO4 Analog 28 db
IEC61850 GGIO4 Analog 28 min
IEC61850 GGIO4 Analog 28 max
IEC61850 GGIO4 Analog 29 Value
IEC61850 GGIO4 Analog 29 db
IEC61850 GGIO4 Analog 29 min
IEC61850 GGIO4 Analog 29 max
IEC61850 GGIO4 Analog 30 Value
IEC61850 GGIO4 Analog 30 db
IEC61850 GGIO4 Analog 30 min
IEC61850 GGIO4 Analog 30 max
IEC61850 GGIO4 Analog 31 Value
IEC61850 GGIO4 Analog 31 db
IEC61850 GGIO4 Analog 31 min
IEC61850 GGIO4 Analog 31 max
IEC61850 GGIO4 Analog 32 Value
IEC61850 GGIO4 Analog 32 db
IEC61850 GGIO4 Analog 32 min
IEC61850 GGIO4 Analog 32 max

100.000 %
0.000
1000000.000
OFF
100.000 %
0.000
1000000.000
OFF
100.000 %
0.000
1000000.000
OFF
100.000 %
0.000
1000000.000
OFF
100.000 %
0.000
1000000.000
OFF
100.000 %
0.000
1000000.000
OFF
100.000 %
0.000
1000000.000
OFF
100.000 %
0.000
1000000.000
OFF
100.000 %
0.000
1000000.000
OFF
100.000 %
0.000
1000000.000

XCBR CONFIGURATION
XCBR1 ST.Loc Operand
Clear XCBR1 OpCnt
XCBR2 ST.Loc Operand
Clear XCBR2 OpCnt

OFF
No
OFF
No

XSWI CONFIGURATION
XSWI1 ST.Loc Operand
XSWI2 ST.Loc Operand
XSWI3 ST.Loc Operand
XSWI4 ST.Loc Operand
XSWI5 ST.Loc Operand
XSWI6 ST.Loc Operand
XSWI7 ST.Loc Operand
XSWI8 ST.Loc Operand
Clear XSWI1 OpCnt
Clear XSWI2 OpCnt
Clear XSWI3 OpCnt
Clear XSWI4 OpCnt
Clear XSWI5 OpCnt
Clear XSWI6 OpCnt
Clear XSWI7 OpCnt
Clear XSWI8 OpCnt

OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
No
No
No
No
No
No
No
No

HTTP
HTTP TCP Port Number

80

TFTP

Fri Oct 14 17:14:31 2016 Version: 7.22 Settings (Enabled Features)

PAGE 6

QUICK CONNECT
QUICK CONNECT DEVICE
DEVICE DEFINITION
ORDER CODE: M60-J03-VKH-F8M-H5C-M6E-PXX
VERSION: 6.0X
DESCRIPTION: (NONE)
INTERFACE: COM2: 19200 N 8 1
TFTP (continued from last page)
TFTP Main UDP Port Number
TFTP Data UDP Port Number 1
TFTP Data UDP Port Number 2

69
0
0

SNTP
Function
Server IP Address
UDP Port Number

Enabled
172. 18. 9.189
123

MODBUS USER MAP


Address 1
Address 2
Address 3
Address 4
Address 5
Address 6
Address 7
Address 8
Address 9
Address 10
Address 11
Address 12
Address 13
Address 14
Address 15
Address 16
Address 17
Address 18
Address 19
Address 20
Address 21
Address 22
Address 23
Address 24
Address 25
Address 26
Address 27
Address 28
Address 29
Address 30
Address 31
Address 32
Address 33
Address 34
Address 35
Address 36
Address 37
Address 38
Address 39

26176
5376
5392
13552
13553
13554
13555
13556
13557
13558
13559
6144
6145
6146
6147
6148
6149
6671
6672
6673
6674
6675
6676
7168
7169
7176
7177
26177
27097
16805
4100
4105
4112
4116
4119
4148
5419
26191
5417

REAL TIME CLOCK


IRIG-B Signal Type
Real Time Clock Events
Time Zone Offset
DST Function
DST Start Month
DST Start Day
DST Start Day Instance
DST Start Hour
DST Stop Month
DST Stop Day
DST Stop Day Instance
DST Stop Hour

None
Enabled
-3.0 hr
Enabled
April
Sunday
First
2
October
Sunday
First
2

OSCILLOGRAPHY
Number Of Records
Trigger Mode
Trigger Position

5
Automatic Overwrite
30 %

Fri Oct 14 17:14:31 2016 Version: 7.22 Settings (Enabled Features)

PAGE 7

QUICK CONNECT
QUICK CONNECT DEVICE
DEVICE DEFINITION
ORDER CODE: M60-J03-VKH-F8M-H5C-M6E-PXX
VERSION: 6.0X
DESCRIPTION: (NONE)
INTERFACE: COM2: 19200 N 8 1
OSCILLOGRAPHY (continued from last page)
Trigger Source
AC Input Waveforms
Digital Channel 1
Digital Channel 2
Digital Channel 3
Digital Channel 4
Digital Channel 5
Digital Channel 6
Digital Channel 7
Digital Channel 8
Digital Channel 9
Digital Channel 10
Digital Channel 11
Digital Channel 12
Digital Channel 13
Digital Channel 14
Digital Channel 15
Digital Channel 16
Digital Channel 17
Digital Channel 18
Digital Channel 19
Digital Channel 20
Digital Channel 21
Digital Channel 22
Digital Channel 23
Digital Channel 24
Digital Channel 25
Digital Channel 26
Analog Channel 1
Analog Channel 2
Analog Channel 3
Analog Channel 4
Analog Channel 5
Analog Channel 6
Analog Channel 7
Analog Channel 8
Analog Channel 9
Analog Channel 10
Analog Channel 11
Analog Channel 12
Analog Channel 13
Analog Channel 14
Analog Channel 15

Osc Trigger On (VO64)


32 samples/cycle
AMP UNBALANCE 1 OP
AUX OV 1 OP
AUX UV 1 OP
DIR POWER 1 OP
GROUND IOC1 OP
GROUND TOC1 OP
MECHANICAL JAM OP
MOTOR OFFLINE
MOTOR OVERLOAD
MOTOR RESTART
MOTOR START INHIBIT
MOTOR ACCEL TIME OP
NEG SEQ OV1 OP
NEUTRAL IOC1 OP
NEUTRAL OV1 OP
NTRL DIR OC1 FWD
NTRL DIR OC1 REV
PHASE IOC1 OP
PHASE OV1 OP
PHASE UV1 OP
RESTART DELAY OP
SRC1 50DD OP
SRC1 VT FUSE FAIL OP
STARTS-PER-HOUR OP
STATOR DIFF OP
TIME-BTWN-STARTS OP
Stator Diff Iad
Stator Rest Iar
Stator Diff Ibd
Stator Rest Ibr
Stator Diff Icd
Stator Rest Icr
SRC1
I_2 Mag
SRC1
I_2 Angle
SRC1
I_0 Mag
SRC1
I_0 Angle
SRC1
PF
SRC2
PF
Therm Mdl Cap Used
Therm Mdl Load
Therm Mdl Curr Unbal

DATA LOGGER
Data Logger Mode
Data Logger Trigger
Rate
Channel 1
Channel 2
Channel 3

Continuous
ON
500 msec
SRC1
Ia RMS
SRC1
Ib RMS
SRC1
Ic RMS

USER-PROGRAMMABLE LEDS
USER PROGRAMMABLE LEDS
LED 1: OPERAND
LED 1: TYPE
LED 2: OPERAND
LED 2: TYPE
LED 3: OPERAND
LED 3: TYPE
LED 4: OPERAND
LED 4: TYPE
LED 5: OPERAND
LED 5: TYPE
LED 6: OPERAND
LED 6: TYPE
LED 7: OPERAND
LED 7: TYPE

Earth. Close On(M7c)


Self-Reset
MCBS Faulty On(M8a)
Self-Reset
MOTOR THERMAL OP
Latched
MOTOR START INHIBIT
Latched
MOTOR OFFLINE
Self-Reset
MOTOR STARTING
Self-Reset
MOTOR RUNNING
Self-Reset

Fri Oct 14 17:14:31 2016 Version: 7.22 Settings (Enabled Features)

PAGE 8

QUICK CONNECT
QUICK CONNECT DEVICE
DEVICE DEFINITION
ORDER CODE: M60-J03-VKH-F8M-H5C-M6E-PXX
VERSION: 6.0X
DESCRIPTION: (NONE)
INTERFACE: COM2: 19200 N 8 1
USER PROGRAMMABLE LEDS (continued from last page)
LED 8: OPERAND
LED 8: TYPE
LED 9: OPERAND
LED 9: TYPE
LED 10: OPERAND
LED 10: TYPE
LED 11: OPERAND
LED 11: TYPE
LED 12: OPERAND
LED 12: TYPE
LED 13: OPERAND
LED 13: TYPE
LED 14: OPERAND
LED 14: TYPE
LED 15: OPERAND
LED 15: TYPE
LED 16: OPERAND
LED 16: TYPE
LED 17: OPERAND
LED 17: TYPE
LED 18: OPERAND
LED 18: TYPE

MOTOR OVERLOAD
Self-Reset
MECHANICAL JAM OP
Latched
AMP UNBALANCE 1 OP
Self-Reset
AMP UNBALANCE 2 OP
Latched
GROUND IOC1 OP
Latched
GROUND IOC2 OP
Latched
PHASE UV1 OP
Latched
PHASE UV2 OP
Latched
MOTOR ACCEL TIME OP
Latched
RTD Alarm On (VO61)
Self-Reset
RTD Trip On (VO62)
Latched

USER-PROGRAMMABLE SELF TESTS


Remote Device Off Function
Battery Fail Function
SNTP Fail Function
IRIG B Fail Function

Enabled
Enabled
Enabled
Enabled

USER-DEFINABLE DISPLAYS
USER DISPLAY 1: Top Line
USER DISPLAY 1: Bottom Line
USER DISPLAY 1: Item 1
USER DISPLAY 1: Item 2
USER DISPLAY 1: Item 3
USER DISPLAY 1: Item 4
USER DISPLAY 1: Item 5
USER DISPLAY 2: Top Line
USER DISPLAY 2: Bottom Line
USER DISPLAY 2: Item 1
USER DISPLAY 2: Item 2
USER DISPLAY 2: Item 3
USER DISPLAY 2: Item 4
USER DISPLAY 2: Item 5
USER DISPLAY 3: Top Line
USER DISPLAY 3: Bottom Line
USER DISPLAY 3: Item 1
USER DISPLAY 3: Item 2
USER DISPLAY 3: Item 3
USER DISPLAY 3: Item 4
USER DISPLAY 3: Item 5
USER DISPLAY 4: Top Line
USER DISPLAY 4: Bottom Line
USER DISPLAY 4: Item 1
USER DISPLAY 4: Item 2
USER DISPLAY 4: Item 3
USER DISPLAY 4: Item 4
USER DISPLAY 4: Item 5
Invoke and Scroll
INSTALLATION
Relay Settings
Relay Name
SYSTEM SETUP
AC INPUTS
CURRENT
CT F1: Phase CT Primary

IL1 ~
L1-G ~
6144
6656
0
0
0
IL2 ~
L2-G ~
6146
6658
0
0
0
IL3 ~
L3-G ~
6148
6660
0
0
0
L1-L2 ~
6671
6671
0
0
0
OFF
Programmed
CV017-M2

100 A

Fri Oct 14 17:14:31 2016 Version: 7.22 Settings (Enabled Features)

PAGE 9

QUICK CONNECT
QUICK CONNECT DEVICE
DEVICE DEFINITION
ORDER CODE: M60-J03-VKH-F8M-H5C-M6E-PXX
VERSION: 6.0X
DESCRIPTION: (NONE)
INTERFACE: COM2: 19200 N 8 1
CURRENT (continued from last page)
CT F1: Phase CT Secondary
CT F1: Ground CT Primary
CT F1: Ground CT Secondary

5A
25 A
1A

VOLTAGE
VT F5: Phase VT Connection
VT F5: Phase VT Secondary
VT F5: Phase VT Ratio
VT F5: Auxiliary VT Connection
VT F5: Auxiliary VT Secondary
VT F5: Auxiliary VT Ratio

Wye
57.0 V
69.00 :1
Vn
66.4 V
1.00 :1

POWER SYSTEM
Nominal Frequency
Phase Rotation
Frequency And Phase Reference
Frequency Tracking Function

50 Hz
ABC
LINE (SRC 1)
Enabled

SIGNAL SOURCES
SOURCE 1: Name
SOURCE 1: Phase CT
SOURCE 1: Ground CT
SOURCE 1: Phase VT
SOURCE 1: Auxiliary VT

LINE
F1
F1
F5
F5

MOTOR
Motor Full Load Amps (FLA)
Motor Overload Factor
Motor Nameplate Voltage
Motor Offline
Motor Emergency Restart
Motor Line Source
Motor Learned Data Starts To Learn
Motor Learned Data Average Calculation Period
2-Speed Motor Protection
Speed2 Motor Switch
Speed2 Switch 2-1 Delay
Speed2 Motor Source
Speed2 Motor FLA

0.932 pu
1.01
6600 volts
Virt Op 2 On (VO2)
OFF
LINE (SRC 1)
1
15 min
Disabled
OFF
5.00 s
LINE (SRC 1)
1.000 pu

FLEXLOGIC
FLEXLOGIC EQUATION EDITOR
FlexLogic Entry 1
FlexLogic Entry 2
FlexLogic Entry 3
FlexLogic Entry 4
FlexLogic Entry 5
FlexLogic Entry 6
FlexLogic Entry 7
FlexLogic Entry 8
FlexLogic Entry 9
FlexLogic Entry 10
FlexLogic Entry 11
FlexLogic Entry 12
FlexLogic Entry 13
FlexLogic Entry 14
FlexLogic Entry 15
FlexLogic Entry 16
FlexLogic Entry 17
FlexLogic Entry 18
FlexLogic Entry 19
FlexLogic Entry 20
FlexLogic Entry 21
FlexLogic Entry 22
FlexLogic Entry 23
FlexLogic Entry 24
FlexLogic Entry 25
FlexLogic Entry 26

AMP UNBALANCE 1 PKP


POSITIVE ONE SHOT
AMP UNBALANCE 1 OP
POSITIVE ONE SHOT
STATOR DIFF PKP A
POSITIVE ONE SHOT
STATOR DIFF PKP B
POSITIVE ONE SHOT
STATOR DIFF PKP C
POSITIVE ONE SHOT
STATOR DIFF OP
POSITIVE ONE SHOT
SRC1 50DD OP
POSITIVE ONE SHOT
GROUND IOC1 PKP
POSITIVE ONE SHOT
GROUND IOC1 OP
POSITIVE ONE SHOT
OR(9)
= Osc Trigger (VO64)
STARTS-PER-HOUR OP
TIME-BTWN-STARTS OP
RESTART DELAY OP
OR(3)
= Start Super. (VO63)
RTD Ip 1 TRIP OP

Fri Oct 14 17:14:31 2016 Version: 7.22 Settings (Enabled Features)

PAGE 10

QUICK CONNECT
QUICK CONNECT DEVICE
DEVICE DEFINITION
ORDER CODE: M60-J03-VKH-F8M-H5C-M6E-PXX
VERSION: 6.0X
DESCRIPTION: (NONE)
INTERFACE: COM2: 19200 N 8 1
FLEXLOGIC EQUATION EDITOR (continued from last page)
FlexLogic Entry 27
FlexLogic Entry 28
FlexLogic Entry 29
FlexLogic Entry 30
FlexLogic Entry 31
FlexLogic Entry 32
FlexLogic Entry 33
FlexLogic Entry 34
FlexLogic Entry 35
FlexLogic Entry 36
FlexLogic Entry 37
FlexLogic Entry 38
FlexLogic Entry 39
FlexLogic Entry 40
FlexLogic Entry 41
FlexLogic Entry 42
FlexLogic Entry 43
FlexLogic Entry 44
FlexLogic Entry 45
FlexLogic Entry 46
FlexLogic Entry 47
FlexLogic Entry 48
FlexLogic Entry 49
FlexLogic Entry 50
FlexLogic Entry 51
FlexLogic Entry 52
FlexLogic Entry 53
FlexLogic Entry 54
FlexLogic Entry 55
FlexLogic Entry 56
FlexLogic Entry 57
FlexLogic Entry 58
FlexLogic Entry 59
FlexLogic Entry 60
FlexLogic Entry 61
FlexLogic Entry 62
FlexLogic Entry 63
FlexLogic Entry 64
FlexLogic Entry 65
FlexLogic Entry 66
FlexLogic Entry 67
FlexLogic Entry 68
FlexLogic Entry 69
FlexLogic Entry 70
FlexLogic Entry 71
FlexLogic Entry 72
FlexLogic Entry 73
FlexLogic Entry 74
FlexLogic Entry 75
FlexLogic Entry 76
FlexLogic Entry 77
FlexLogic Entry 78
FlexLogic Entry 79
FlexLogic Entry 80
FlexLogic Entry 81
FlexLogic Entry 82
FlexLogic Entry 83
FlexLogic Entry 84
FlexLogic Entry 85
FlexLogic Entry 86
FlexLogic Entry 87
FlexLogic Entry 88
FlexLogic Entry 89
FlexLogic Entry 90
FlexLogic Entry 91
FlexLogic Entry 92
FlexLogic Entry 93
FlexLogic Entry 94

RTD Ip 2 TRIP OP
RTD Ip 3 TRIP OP
RTD Ip 4 TRIP OP
RTD Ip 5 TRIP OP
RTD Ip 6 TRIP OP
RTD Ip 7 TRIP OP
RTD Ip 8 TRIP OP
Off
Off
Off
Off
Off
Off
Off
Off
OR(16)
Off
Off
Off
Off
Off
Off
Off
Off
OR(9)
= RTD Trip (VO62)
RTD Ip 1 ALARM OP
RTD Ip 2 ALARM OP
RTD Ip 3 ALARM OP
RTD Ip 4 ALARM OP
RTD Ip 5 ALARM OP
RTD Ip 6 ALARM OP
RTD Ip 7 ALARM OP
RTD Ip 8 ALARM OP
Off
Off
Off
Off
Off
Off
Off
Off
OR(16)
Off
Off
Off
Off
Off
Off
Off
Off
RTD Ip 1 OPEN
RTD Ip 2 OPEN
RTD Ip 3 OPEN
RTD Ip 4 OPEN
RTD Ip 5 OPEN
RTD Ip 6 OPEN
RTD Ip 7 OPEN
OR(16)
RTD Ip 8 OPEN
Off
Off
Off
Off
Off
Off
Off
Off

Fri Oct 14 17:14:31 2016 Version: 7.22 Settings (Enabled Features)

PAGE 11

QUICK CONNECT
QUICK CONNECT DEVICE
DEVICE DEFINITION
ORDER CODE: M60-J03-VKH-F8M-H5C-M6E-PXX
VERSION: 6.0X
DESCRIPTION: (NONE)
INTERFACE: COM2: 19200 N 8 1
FLEXLOGIC EQUATION EDITOR (continued from last page)
FlexLogic Entry 95
FlexLogic Entry 96
FlexLogic Entry 97
FlexLogic Entry 98
FlexLogic Entry 99
FlexLogic Entry 100
FlexLogic Entry 101
FlexLogic Entry 102
FlexLogic Entry 103
FlexLogic Entry 104
FlexLogic Entry 105
FlexLogic Entry 106
FlexLogic Entry 107
FlexLogic Entry 108
FlexLogic Entry 109
FlexLogic Entry 110
FlexLogic Entry 111
FlexLogic Entry 112
FlexLogic Entry 113
FlexLogic Entry 114
FlexLogic Entry 115
FlexLogic Entry 116
FlexLogic Entry 117
FlexLogic Entry 118
FlexLogic Entry 119
FlexLogic Entry 120
FlexLogic Entry 121
FlexLogic Entry 122
FlexLogic Entry 123
FlexLogic Entry 124
FlexLogic Entry 125
FlexLogic Entry 126
FlexLogic Entry 127
FlexLogic Entry 128
FlexLogic Entry 129
FlexLogic Entry 130
FlexLogic Entry 131
FlexLogic Entry 132
FlexLogic Entry 133
FlexLogic Entry 134
FlexLogic Entry 135
FlexLogic Entry 136
FlexLogic Entry 137
FlexLogic Entry 138
FlexLogic Entry 139
GROUPED ELEMENTS
GROUP 1
MOTOR
ACCELERATION TIME [GROUP 1]
Function
Current
Time
Mode
Block
Target
Events
THERMAL MODEL [GROUP 1]
Function
Curve
Thermal Model IEC Curve k Factor
IEC Curve Time Constant
Curve Effect
TD Multiplier
Bias K Factor
Cool Time Constant Running
Cool Time Constant Stopped

Off
Off
Off
Off
Off
Off
OR(16)
Off
Off
RTD Ip 1 SHORTED
RTD Ip 2 SHORTED
RTD Ip 3 SHORTED
RTD Ip 4 SHORTED
RTD Ip 5 SHORTED
RTD Ip 6 SHORTED
RTD Ip 7 SHORTED
RTD Ip 8 SHORTED
Off
Off
Off
Off
Off
OR(16)
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
OR(12)
= RTD Alarm (VO61)
Off
MOTOR START INHIBIT
OR(2)
= Virt Op 1 (VO1)
Off
Cont. Close Off(M7a)
OR(2)
= Virt Op 2 (VO2)
END

Enabled
1.30 x FLA
88.00 s
Adaptive
OFF
Latched
Enabled
Enabled
Motor
1.10
45 min
Cutoff
1.00
6
15 min
30 min

Fri Oct 14 17:14:31 2016 Version: 7.22 Settings (Enabled Features)

PAGE 12

QUICK CONNECT
QUICK CONNECT DEVICE
DEVICE DEFINITION
ORDER CODE: M60-J03-VKH-F8M-H5C-M6E-PXX
VERSION: 6.0X
DESCRIPTION: (NONE)
INTERFACE: COM2: 19200 N 8 1
THERMAL MODEL [GROUP 1] (continued from last page)
Hot/Cold Safe Stall Ratio
RTD Bias
RTD Bias Min
RTD Bias Center
RTD Bias Max
Start Inhibit Margin
Voltage Dependent Function
Voltage Dependent Min Motor Volts
Voltage Dependent Voltage Loss
Voltage Dependent Stall Current Min Volts
Voltage Dependent Safe Stall Time Min Volts
Voltage Dependent Accel Intersect Min Volts
Voltage Dependent Stall current @100% Volts
Voltage Dependent Safe Stall Time @100% Volts
Voltage Dependent Accel Intersect @100% Volts
Block
Target
Events

0.66
Enabled
40 C
130 C
155 C
25 %
Disabled
80 %
OFF
3.70 x FLA
16.4 sec
3.00 x FLA
5.80 x FLA
10.5 sec
5.00 x FLA
OFF
Latched
Enabled

AMP UNBALANCE [GROUP 1]


AMP UNBALANCE 1: Function
AMP UNBALANCE 1: Pickup
AMP UNBALANCE 1: Pickup Delay
AMP UNBALANCE 1: Reset Delay
AMP UNBALANCE 1: Block
AMP UNBALANCE 1: Targets
AMP UNBALANCE 1: Events
AMP UNBALANCE 2: Function
AMP UNBALANCE 2: Pickup
AMP UNBALANCE 2: Pickup Delay
AMP UNBALANCE 2: Reset Delay
AMP UNBALANCE 2: Block
AMP UNBALANCE 2: Targets
AMP UNBALANCE 2: Events

Enabled
15.0 %
10.00 s
0.00 s
OFF
Self-reset
Enabled
Enabled
20.0 %
5.00 s
0.00 s
OFF
Latched
Enabled

MECHANICAL JAM [GROUP 1]


Function
Pickup
Pickup Delay
Reset Delay
Block
Target
Events

Enabled
2.00 X FLA
1.00 s
0.00 s
OFF
Latched
Enabled

TWO-SPEED MOTOR
THERMAL MODEL [GROUP 1]
Speed2 Thermal Model Curve
Speed2 Thermal Model TD Multiplier
Speed2 Voltage Dependant Function

Motor
1.00
Disabled

ACCELERATION TIME [GROUP 1]


Speed2 Acceleration Current
Speed2 Acceleration Time
Speed2 Acceleration Mode
Speed2 Acceleration Time Speed 1-2
Speed2 Acceleration Block

6.00 x FLA
10.00 s
Definite Time
10.00 s
OFF

UNDERCURRENT [GROUP 1]
Speed2 Undercurrent Start Block Delay
Speed2 Undercurrent Alarm Pickup
Speed2 Undercurrent Alarm Pickup Delay
Speed2 Undercurrent Trip Pickup
Speed2 Undercurrent Trip Pickup Delay
Speed2 Undercurrent Trip Reset Delay
Speed2 Undercurrent Block

0.50 s
0.70 x FLA
2.00 s
0.70 x FLA
1.00 s
1.00 s
OFF

GROUND CURRENT
GROUND IOC [GROUP 1]

Fri Oct 14 17:14:31 2016 Version: 7.22 Settings (Enabled Features)

PAGE 13

QUICK CONNECT
QUICK CONNECT DEVICE
DEVICE DEFINITION
ORDER CODE: M60-J03-VKH-F8M-H5C-M6E-PXX
VERSION: 6.0X
DESCRIPTION: (NONE)
INTERFACE: COM2: 19200 N 8 1
GROUND IOC [GROUP 1] (continued from last page)
GROUND IOC1: Function
GROUND IOC1: Source
GROUND IOC1: Pickup
GROUND IOC1: Delay
GROUND IOC1: Reset Delay
GROUND IOC1: Block
GROUND IOC1: Target
GROUND IOC1: Events

Enabled
LINE (SRC 1)
0.100 pu
0.10 s
0.00 s
OFF
Self-reset
Enabled

BREAKER FAILURE [GROUP 1]


BF1: Function
BF1: Mode
BF1: Source
BF1: Current Supervision
BF1: Use Seal-In
BF1: Three Pole Initiate
BF1: Block
BF1: Phase Current Supv Pickup
BF1: Neutral Current Supv Pickup
BF1: Use Timer 1
BF1: Timer 1 Pickup Delay
BF1: Use Timer 2
BF1: Timer 2 Pickup Delay
BF1: Use Timer 3
BF1: Timer 3 Pickup Delay
BF1: Breaker Pos1 Phase A/3P
BF1: Breaker Pos2 Phase A/3P
BF1: Breaker Test On
BF1: Phase Current HiSet Pickup
BF1: Neutral Current HiSet Pickup
BF1: Phase Current LoSet Pickup
BF1: Neutral Current LoSet Pickup
BF1: LoSet Time Delay
BF1: Trip Dropout Delay
BF1: Target
BF1: Events
BF1: Phase A Initiate
BF1: Phase B Initiate
BF1: Phase C Initiate
BF1: Breaker Pos1 Phase B
BF1: Breaker Pos1 Phase C
BF1: Breaker Pos2 Phase B
BF1: Breaker Pos2 Phase C

Enabled
3-Pole
LINE (SRC 1)
Yes
Yes
OFF
OFF
1.050 pu
1.050 pu
Yes
0.000 s
Yes
0.000 s
Yes
0.000 s
Bkr_Sts On(M5a)
OFF
OFF
1.050 pu
1.050 pu
1.050 pu
1.050 pu
0.000 s
0.000 s
Latched
Enabled
OFF
OFF
OFF
OFF
OFF
OFF
OFF

VOLTAGE ELEMENTS
PHASE UV [GROUP 1]
PHASE UV1: Function
PHASE UV1: Signal Source
PHASE UV1: Mode
PHASE UV1: Pickup
PHASE UV1: Curve
PHASE UV1: Delay
PHASE UV1: Minimum Voltage
PHASE UV1: Block
PHASE UV1: Target
PHASE UV1: Events
GROUP 2
MOTOR
ACCELERATION TIME [GROUP 2]
Function
Current
Time
Mode
Block
Target
Events

Enabled
LINE (SRC 1)
Phase to Phase
0.700 pu
Definite Time
2.00 s
0.300 pu
OFF
Self-reset
Enabled

Enabled
6.00 x FLA
14.40 s
Definite Time
OFF
Latched
Enabled

Fri Oct 14 17:14:31 2016 Version: 7.22 Settings (Enabled Features)

PAGE 14

QUICK CONNECT
QUICK CONNECT DEVICE
DEVICE DEFINITION
ORDER CODE: M60-J03-VKH-F8M-H5C-M6E-PXX
VERSION: 6.0X
DESCRIPTION: (NONE)
INTERFACE: COM2: 19200 N 8 1
THERMAL MODEL [GROUP 2]
Function
Curve
Thermal Model IEC Curve k Factor
IEC Curve Time Constant
Curve Effect
TD Multiplier
Bias K Factor
Cool Time Constant Running
Cool Time Constant Stopped
Hot/Cold Safe Stall Ratio
RTD Bias
RTD Bias Min
RTD Bias Center
RTD Bias Max
Start Inhibit Margin
Voltage Dependent Function
Voltage Dependent Min Motor Volts
Voltage Dependent Voltage Loss
Voltage Dependent Stall Current Min Volts
Voltage Dependent Safe Stall Time Min Volts
Voltage Dependent Accel Intersect Min Volts
Voltage Dependent Stall current @100% Volts
Voltage Dependent Safe Stall Time @100% Volts
Voltage Dependent Accel Intersect @100% Volts
Block
Target
Events

Enabled
Motor
1.10
45 min
Cutoff
7.00
6
15 min
30 min
0.75
Enabled
40 C
130 C
155 C
0%
Enabled
80 %
OFF
4.50 x FLA
12.0 sec
4.00 x FLA
6.00 x FLA
10.0 sec
5.00 x FLA
OFF
Latched
Enabled

AMP UNBALANCE [GROUP 2]


AMP UNBALANCE 1: Function
AMP UNBALANCE 1: Pickup
AMP UNBALANCE 1: Pickup Delay
AMP UNBALANCE 1: Reset Delay
AMP UNBALANCE 1: Block
AMP UNBALANCE 1: Targets
AMP UNBALANCE 1: Events
AMP UNBALANCE 2: Function
AMP UNBALANCE 2: Pickup
AMP UNBALANCE 2: Pickup Delay
AMP UNBALANCE 2: Reset Delay
AMP UNBALANCE 2: Block
AMP UNBALANCE 2: Targets
AMP UNBALANCE 2: Events

Enabled
15.0 %
10.00 s
0.00 s
OFF
Self-reset
Enabled
Enabled
20.0 %
5.00 s
0.00 s
OFF
Latched
Enabled

MECHANICAL JAM [GROUP 2]


Function
Pickup
Pickup Delay
Reset Delay
Block
Target
Events

Enabled
3.00 X FLA
2.50 s
0.00 s
OFF
Latched
Enabled

TWO-SPEED MOTOR
THERMAL MODEL [GROUP 2]
Speed2 Thermal Model Curve
Speed2 Thermal Model TD Multiplier
Speed2 Voltage Dependant Function

Motor
1.00
Disabled

ACCELERATION TIME [GROUP 2]


Speed2 Acceleration Current
Speed2 Acceleration Time
Speed2 Acceleration Mode
Speed2 Acceleration Time Speed 1-2
Speed2 Acceleration Block

6.00 x FLA
10.00 s
Definite Time
10.00 s
OFF

UNDERCURRENT [GROUP 2]
Speed2 Undercurrent Start Block Delay

0.50 s

Fri Oct 14 17:14:31 2016 Version: 7.22 Settings (Enabled Features)

PAGE 15

QUICK CONNECT
QUICK CONNECT DEVICE
DEVICE DEFINITION
ORDER CODE: M60-J03-VKH-F8M-H5C-M6E-PXX
VERSION: 6.0X
DESCRIPTION: (NONE)
INTERFACE: COM2: 19200 N 8 1
UNDERCURRENT [GROUP 2] (continued from last page)
Speed2 Undercurrent Alarm Pickup
Speed2 Undercurrent Alarm Pickup Delay
Speed2 Undercurrent Trip Pickup
Speed2 Undercurrent Trip Pickup Delay
Speed2 Undercurrent Trip Reset Delay
Speed2 Undercurrent Block

0.70 x FLA
2.00 s
0.70 x FLA
1.00 s
1.00 s
OFF

PHASE CURRENT
PHASE DIRECTIONAL [GROUP 2]
PHASE DIR1: Function
PHASE DIR1: Source
PHASE DIR1: Block
PHASE DIR1: ECA
PHASE DIR1: Pol V Threshold
PHASE DIR1: Block when V Mem Exp
PHASE DIR1: Target
PHASE DIR1: Events

Enabled
LINE (SRC 1)
OFF
30 deg
0.700 pu
No
Latched
Enabled

GROUND CURRENT
GROUND IOC [GROUP 2]
GROUND IOC1: Function
GROUND IOC1: Source
GROUND IOC1: Pickup
GROUND IOC1: Delay
GROUND IOC1: Reset Delay
GROUND IOC1: Block
GROUND IOC1: Target
GROUND IOC1: Events
GROUND IOC2: Function
GROUND IOC2: Source
GROUND IOC2: Pickup
GROUND IOC2: Delay
GROUND IOC2: Reset Delay
GROUND IOC2: Block
GROUND IOC2: Target
GROUND IOC2: Events

Enabled
LINE (SRC 1)
0.100 pu
0.20 s
0.00 s
OFF
Self-reset
Enabled
Enabled
LINE (SRC 1)
0.150 pu
0.00 s
0.00 s
OFF
Latched
Enabled

BREAKER FAILURE [GROUP 2]


BF1: Function
BF1: Mode
BF1: Source
BF1: Current Supervision
BF1: Use Seal-In
BF1: Three Pole Initiate
BF1: Block
BF1: Phase Current Supv Pickup
BF1: Neutral Current Supv Pickup
BF1: Use Timer 1
BF1: Timer 1 Pickup Delay
BF1: Use Timer 2
BF1: Timer 2 Pickup Delay
BF1: Use Timer 3
BF1: Timer 3 Pickup Delay
BF1: Breaker Pos1 Phase A/3P
BF1: Breaker Pos2 Phase A/3P
BF1: Breaker Test On
BF1: Phase Current HiSet Pickup
BF1: Neutral Current HiSet Pickup
BF1: Phase Current LoSet Pickup
BF1: Neutral Current LoSet Pickup
BF1: LoSet Time Delay
BF1: Trip Dropout Delay
BF1: Target
BF1: Events
BF1: Phase A Initiate
BF1: Phase B Initiate
BF1: Phase C Initiate
BF1: Breaker Pos1 Phase B

Enabled
3-Pole
LINE (SRC 1)
Yes
Yes
OFF
OFF
1.050 pu
1.050 pu
Yes
0.000 s
Yes
0.000 s
Yes
0.000 s
Bkr_Sts On(M5a)
OFF
OFF
1.050 pu
1.050 pu
1.050 pu
1.050 pu
0.000 s
0.000 s
Latched
Enabled
OFF
OFF
OFF
OFF

Fri Oct 14 17:14:31 2016 Version: 7.22 Settings (Enabled Features)

PAGE 16

QUICK CONNECT
QUICK CONNECT DEVICE
DEVICE DEFINITION
ORDER CODE: M60-J03-VKH-F8M-H5C-M6E-PXX
VERSION: 6.0X
DESCRIPTION: (NONE)
INTERFACE: COM2: 19200 N 8 1
BREAKER FAILURE [GROUP 2] (continued from last page)
BF1: Breaker Pos1 Phase C
BF1: Breaker Pos2 Phase B
BF1: Breaker Pos2 Phase C
VOLTAGE ELEMENTS
PHASE UV [GROUP 2]
PHASE UV1: Function
PHASE UV1: Signal Source
PHASE UV1: Mode
PHASE UV1: Pickup
PHASE UV1: Curve
PHASE UV1: Delay
PHASE UV1: Minimum Voltage
PHASE UV1: Block
PHASE UV1: Target
PHASE UV1: Events
PHASE UV2: Function
PHASE UV2: Signal Source
PHASE UV2: Mode
PHASE UV2: Pickup
PHASE UV2: Curve
PHASE UV2: Delay
PHASE UV2: Minimum Voltage
PHASE UV2: Block
PHASE UV2: Target
PHASE UV2: Events
PHASE OV [GROUP 2]
PHASE OV1: Function
PHASE OV1: Source
PHASE OV1: Pickup
PHASE OV1: Delay
PHASE OV1: Reset Delay
PHASE OV1: Block
PHASE OV1: Target
PHASE OV1: Events
GROUP 3
MOTOR
ACCELERATION TIME [GROUP 3]
Function
Current
Time
Mode
Block
Target
Events
THERMAL MODEL [GROUP 3]
Function
Curve
Thermal Model IEC Curve k Factor
IEC Curve Time Constant
Curve Effect
TD Multiplier
Bias K Factor
Cool Time Constant Running
Cool Time Constant Stopped
Hot/Cold Safe Stall Ratio
RTD Bias
RTD Bias Min
RTD Bias Center
RTD Bias Max
Start Inhibit Margin
Voltage Dependent Function
Voltage Dependent Min Motor Volts
Voltage Dependent Voltage Loss
Voltage Dependent Stall Current Min Volts

OFF
OFF
OFF

Enabled
LINE (SRC 1)
Phase to Ground
0.850 pu
Definite Time
10.00 s
0.100 pu
OFF
Self-reset
Enabled
Enabled
LINE (SRC 1)
Phase to Ground
0.800 pu
Definite Time
3.00 s
0.100 pu
OFF
Latched
Enabled
Enabled
LINE (SRC 1)
1.100 pu
3.00 s
1.00 s
OFF
Self-reset
Enabled

Enabled
6.00 x FLA
14.40 s
Definite Time
OFF
Latched
Enabled
Enabled
Motor
1.10
45 min
Cutoff
7.00
6
15 min
30 min
0.75
Enabled
40 C
130 C
155 C
0%
Enabled
80 %
OFF
4.50 x FLA

Fri Oct 14 17:14:31 2016 Version: 7.22 Settings (Enabled Features)

PAGE 17

QUICK CONNECT
QUICK CONNECT DEVICE
DEVICE DEFINITION
ORDER CODE: M60-J03-VKH-F8M-H5C-M6E-PXX
VERSION: 6.0X
DESCRIPTION: (NONE)
INTERFACE: COM2: 19200 N 8 1
THERMAL MODEL [GROUP 3] (continued from last page)
Voltage Dependent Safe Stall Time Min Volts
Voltage Dependent Accel Intersect Min Volts
Voltage Dependent Stall current @100% Volts
Voltage Dependent Safe Stall Time @100% Volts
Voltage Dependent Accel Intersect @100% Volts
Block
Target
Events

12.0 sec
4.00 x FLA
6.00 x FLA
10.0 sec
5.00 x FLA
OFF
Latched
Enabled

AMP UNBALANCE [GROUP 3]


AMP UNBALANCE 1: Function
AMP UNBALANCE 1: Pickup
AMP UNBALANCE 1: Pickup Delay
AMP UNBALANCE 1: Reset Delay
AMP UNBALANCE 1: Block
AMP UNBALANCE 1: Targets
AMP UNBALANCE 1: Events
AMP UNBALANCE 2: Function
AMP UNBALANCE 2: Pickup
AMP UNBALANCE 2: Pickup Delay
AMP UNBALANCE 2: Reset Delay
AMP UNBALANCE 2: Block
AMP UNBALANCE 2: Targets
AMP UNBALANCE 2: Events

Enabled
15.0 %
10.00 s
0.00 s
OFF
Self-reset
Enabled
Enabled
20.0 %
5.00 s
0.00 s
OFF
Latched
Enabled

MECHANICAL JAM [GROUP 3]


Function
Pickup
Pickup Delay
Reset Delay
Block
Target
Events

Enabled
3.00 X FLA
2.50 s
0.00 s
OFF
Latched
Enabled

TWO-SPEED MOTOR
THERMAL MODEL [GROUP 3]
Speed2 Thermal Model Curve
Speed2 Thermal Model TD Multiplier
Speed2 Voltage Dependant Function

Motor
1.00
Disabled

ACCELERATION TIME [GROUP 3]


Speed2 Acceleration Current
Speed2 Acceleration Time
Speed2 Acceleration Mode
Speed2 Acceleration Time Speed 1-2
Speed2 Acceleration Block

6.00 x FLA
10.00 s
Definite Time
10.00 s
OFF

UNDERCURRENT [GROUP 3]
Speed2 Undercurrent Start Block Delay
Speed2 Undercurrent Alarm Pickup
Speed2 Undercurrent Alarm Pickup Delay
Speed2 Undercurrent Trip Pickup
Speed2 Undercurrent Trip Pickup Delay
Speed2 Undercurrent Trip Reset Delay
Speed2 Undercurrent Block

0.50 s
0.70 x FLA
2.00 s
0.70 x FLA
1.00 s
1.00 s
OFF

PHASE CURRENT
PHASE DIRECTIONAL [GROUP 3]
PHASE DIR1: Function
PHASE DIR1: Source
PHASE DIR1: Block
PHASE DIR1: ECA
PHASE DIR1: Pol V Threshold
PHASE DIR1: Block when V Mem Exp
PHASE DIR1: Target
PHASE DIR1: Events
GROUND CURRENT

Enabled
LINE (SRC 1)
OFF
30 deg
0.700 pu
No
Latched
Enabled

Fri Oct 14 17:14:31 2016 Version: 7.22 Settings (Enabled Features)

PAGE 18

QUICK CONNECT
QUICK CONNECT DEVICE
DEVICE DEFINITION
ORDER CODE: M60-J03-VKH-F8M-H5C-M6E-PXX
VERSION: 6.0X
DESCRIPTION: (NONE)
INTERFACE: COM2: 19200 N 8 1
GROUND IOC [GROUP 3]
GROUND IOC1: Function
GROUND IOC1: Source
GROUND IOC1: Pickup
GROUND IOC1: Delay
GROUND IOC1: Reset Delay
GROUND IOC1: Block
GROUND IOC1: Target
GROUND IOC1: Events
GROUND IOC2: Function
GROUND IOC2: Source
GROUND IOC2: Pickup
GROUND IOC2: Delay
GROUND IOC2: Reset Delay
GROUND IOC2: Block
GROUND IOC2: Target
GROUND IOC2: Events

Enabled
LINE (SRC 1)
0.100 pu
0.20 s
0.00 s
OFF
Self-reset
Enabled
Enabled
LINE (SRC 1)
0.150 pu
0.00 s
0.00 s
OFF
Latched
Enabled

BREAKER FAILURE [GROUP 3]


BF1: Function
BF1: Mode
BF1: Source
BF1: Current Supervision
BF1: Use Seal-In
BF1: Three Pole Initiate
BF1: Block
BF1: Phase Current Supv Pickup
BF1: Neutral Current Supv Pickup
BF1: Use Timer 1
BF1: Timer 1 Pickup Delay
BF1: Use Timer 2
BF1: Timer 2 Pickup Delay
BF1: Use Timer 3
BF1: Timer 3 Pickup Delay
BF1: Breaker Pos1 Phase A/3P
BF1: Breaker Pos2 Phase A/3P
BF1: Breaker Test On
BF1: Phase Current HiSet Pickup
BF1: Neutral Current HiSet Pickup
BF1: Phase Current LoSet Pickup
BF1: Neutral Current LoSet Pickup
BF1: LoSet Time Delay
BF1: Trip Dropout Delay
BF1: Target
BF1: Events
BF1: Phase A Initiate
BF1: Phase B Initiate
BF1: Phase C Initiate
BF1: Breaker Pos1 Phase B
BF1: Breaker Pos1 Phase C
BF1: Breaker Pos2 Phase B
BF1: Breaker Pos2 Phase C

Enabled
3-Pole
LINE (SRC 1)
Yes
Yes
OFF
OFF
1.050 pu
1.050 pu
Yes
0.000 s
Yes
0.000 s
Yes
0.000 s
Bkr_Sts On(M5a)
OFF
OFF
1.050 pu
1.050 pu
1.050 pu
1.050 pu
0.000 s
0.000 s
Latched
Enabled
OFF
OFF
OFF
OFF
OFF
OFF
OFF

VOLTAGE ELEMENTS
PHASE UV [GROUP 3]
PHASE UV1: Function
PHASE UV1: Signal Source
PHASE UV1: Mode
PHASE UV1: Pickup
PHASE UV1: Curve
PHASE UV1: Delay
PHASE UV1: Minimum Voltage
PHASE UV1: Block
PHASE UV1: Target
PHASE UV1: Events
PHASE UV2: Function
PHASE UV2: Signal Source
PHASE UV2: Mode
PHASE UV2: Pickup

Enabled
LINE (SRC 1)
Phase to Ground
0.850 pu
Definite Time
10.00 s
0.100 pu
OFF
Self-reset
Enabled
Enabled
LINE (SRC 1)
Phase to Ground
0.800 pu

Fri Oct 14 17:14:31 2016 Version: 7.22 Settings (Enabled Features)

PAGE 19

QUICK CONNECT
QUICK CONNECT DEVICE
DEVICE DEFINITION
ORDER CODE: M60-J03-VKH-F8M-H5C-M6E-PXX
VERSION: 6.0X
DESCRIPTION: (NONE)
INTERFACE: COM2: 19200 N 8 1
PHASE UV [GROUP 3] (continued from last page)
PHASE UV2: Curve
PHASE UV2: Delay
PHASE UV2: Minimum Voltage
PHASE UV2: Block
PHASE UV2: Target
PHASE UV2: Events

Definite Time
3.00 s
0.100 pu
OFF
Latched
Enabled

PHASE OV [GROUP 3]
PHASE OV1: Function
PHASE OV1: Source
PHASE OV1: Pickup
PHASE OV1: Delay
PHASE OV1: Reset Delay
PHASE OV1: Block
PHASE OV1: Target
PHASE OV1: Events

Enabled
LINE (SRC 1)
1.100 pu
3.00 s
1.00 s
OFF
Self-reset
Enabled

GROUP 4
MOTOR
ACCELERATION TIME [GROUP 4]
Function
Current
Time
Mode
Block
Target
Events

Enabled
6.00 x FLA
14.40 s
Definite Time
OFF
Latched
Enabled

THERMAL MODEL [GROUP 4]


Function
Curve
Thermal Model IEC Curve k Factor
IEC Curve Time Constant
Curve Effect
TD Multiplier
Bias K Factor
Cool Time Constant Running
Cool Time Constant Stopped
Hot/Cold Safe Stall Ratio
RTD Bias
RTD Bias Min
RTD Bias Center
RTD Bias Max
Start Inhibit Margin
Voltage Dependent Function
Voltage Dependent Min Motor Volts
Voltage Dependent Voltage Loss
Voltage Dependent Stall Current Min Volts
Voltage Dependent Safe Stall Time Min Volts
Voltage Dependent Accel Intersect Min Volts
Voltage Dependent Stall current @100% Volts
Voltage Dependent Safe Stall Time @100% Volts
Voltage Dependent Accel Intersect @100% Volts
Block
Target
Events

Enabled
Motor
1.10
45 min
Cutoff
7.00
6
15 min
30 min
0.75
Enabled
40 C
130 C
155 C
0%
Enabled
80 %
OFF
4.50 x FLA
12.0 sec
4.00 x FLA
6.00 x FLA
10.0 sec
5.00 x FLA
OFF
Latched
Enabled

AMP UNBALANCE [GROUP 4]


AMP UNBALANCE 1: Function
AMP UNBALANCE 1: Pickup
AMP UNBALANCE 1: Pickup Delay
AMP UNBALANCE 1: Reset Delay
AMP UNBALANCE 1: Block
AMP UNBALANCE 1: Targets
AMP UNBALANCE 1: Events
AMP UNBALANCE 2: Function
AMP UNBALANCE 2: Pickup
AMP UNBALANCE 2: Pickup Delay

Enabled
15.0 %
10.00 s
0.00 s
OFF
Self-reset
Enabled
Enabled
20.0 %
5.00 s

Fri Oct 14 17:14:31 2016 Version: 7.22 Settings (Enabled Features)

PAGE 20

QUICK CONNECT
QUICK CONNECT DEVICE
DEVICE DEFINITION
ORDER CODE: M60-J03-VKH-F8M-H5C-M6E-PXX
VERSION: 6.0X
DESCRIPTION: (NONE)
INTERFACE: COM2: 19200 N 8 1
AMP UNBALANCE [GROUP 4] (continued from last page)
AMP UNBALANCE 2: Reset Delay
AMP UNBALANCE 2: Block
AMP UNBALANCE 2: Targets
AMP UNBALANCE 2: Events

0.00 s
OFF
Latched
Enabled

MECHANICAL JAM [GROUP 4]


Function
Pickup
Pickup Delay
Reset Delay
Block
Target
Events

Enabled
3.00 X FLA
2.50 s
0.00 s
OFF
Latched
Enabled

TWO-SPEED MOTOR
THERMAL MODEL [GROUP 4]
Speed2 Thermal Model Curve
Speed2 Thermal Model TD Multiplier
Speed2 Voltage Dependant Function

Motor
1.00
Disabled

ACCELERATION TIME [GROUP 4]


Speed2 Acceleration Current
Speed2 Acceleration Time
Speed2 Acceleration Mode
Speed2 Acceleration Time Speed 1-2
Speed2 Acceleration Block

6.00 x FLA
10.00 s
Definite Time
10.00 s
OFF

UNDERCURRENT [GROUP 4]
Speed2 Undercurrent Start Block Delay
Speed2 Undercurrent Alarm Pickup
Speed2 Undercurrent Alarm Pickup Delay
Speed2 Undercurrent Trip Pickup
Speed2 Undercurrent Trip Pickup Delay
Speed2 Undercurrent Trip Reset Delay
Speed2 Undercurrent Block

0.50 s
0.70 x FLA
2.00 s
0.70 x FLA
1.00 s
1.00 s
OFF

PHASE CURRENT
PHASE DIRECTIONAL [GROUP 4]
PHASE DIR1: Function
PHASE DIR1: Source
PHASE DIR1: Block
PHASE DIR1: ECA
PHASE DIR1: Pol V Threshold
PHASE DIR1: Block when V Mem Exp
PHASE DIR1: Target
PHASE DIR1: Events

Enabled
LINE (SRC 1)
OFF
30 deg
0.700 pu
No
Latched
Enabled

GROUND CURRENT
GROUND IOC [GROUP 4]
GROUND IOC1: Function
GROUND IOC1: Source
GROUND IOC1: Pickup
GROUND IOC1: Delay
GROUND IOC1: Reset Delay
GROUND IOC1: Block
GROUND IOC1: Target
GROUND IOC1: Events
GROUND IOC2: Function
GROUND IOC2: Source
GROUND IOC2: Pickup
GROUND IOC2: Delay
GROUND IOC2: Reset Delay
GROUND IOC2: Block
GROUND IOC2: Target
GROUND IOC2: Events

Enabled
LINE (SRC 1)
0.100 pu
0.20 s
0.00 s
OFF
Self-reset
Enabled
Enabled
LINE (SRC 1)
0.150 pu
0.00 s
0.00 s
OFF
Latched
Enabled

BREAKER FAILURE [GROUP 4]


BF1: Function

Enabled

Fri Oct 14 17:14:31 2016 Version: 7.22 Settings (Enabled Features)

PAGE 21

QUICK CONNECT
QUICK CONNECT DEVICE
DEVICE DEFINITION
ORDER CODE: M60-J03-VKH-F8M-H5C-M6E-PXX
VERSION: 6.0X
DESCRIPTION: (NONE)
INTERFACE: COM2: 19200 N 8 1
BREAKER FAILURE [GROUP 4] (continued from last page)
BF1: Mode
BF1: Source
BF1: Current Supervision
BF1: Use Seal-In
BF1: Three Pole Initiate
BF1: Block
BF1: Phase Current Supv Pickup
BF1: Neutral Current Supv Pickup
BF1: Use Timer 1
BF1: Timer 1 Pickup Delay
BF1: Use Timer 2
BF1: Timer 2 Pickup Delay
BF1: Use Timer 3
BF1: Timer 3 Pickup Delay
BF1: Breaker Pos1 Phase A/3P
BF1: Breaker Pos2 Phase A/3P
BF1: Breaker Test On
BF1: Phase Current HiSet Pickup
BF1: Neutral Current HiSet Pickup
BF1: Phase Current LoSet Pickup
BF1: Neutral Current LoSet Pickup
BF1: LoSet Time Delay
BF1: Trip Dropout Delay
BF1: Target
BF1: Events
BF1: Phase A Initiate
BF1: Phase B Initiate
BF1: Phase C Initiate
BF1: Breaker Pos1 Phase B
BF1: Breaker Pos1 Phase C
BF1: Breaker Pos2 Phase B
BF1: Breaker Pos2 Phase C
VOLTAGE ELEMENTS
PHASE UV [GROUP 4]
PHASE UV1: Function
PHASE UV1: Signal Source
PHASE UV1: Mode
PHASE UV1: Pickup
PHASE UV1: Curve
PHASE UV1: Delay
PHASE UV1: Minimum Voltage
PHASE UV1: Block
PHASE UV1: Target
PHASE UV1: Events
PHASE UV2: Function
PHASE UV2: Signal Source
PHASE UV2: Mode
PHASE UV2: Pickup
PHASE UV2: Curve
PHASE UV2: Delay
PHASE UV2: Minimum Voltage
PHASE UV2: Block
PHASE UV2: Target
PHASE UV2: Events
PHASE OV [GROUP 4]
PHASE OV1: Function
PHASE OV1: Source
PHASE OV1: Pickup
PHASE OV1: Delay
PHASE OV1: Reset Delay
PHASE OV1: Block
PHASE OV1: Target
PHASE OV1: Events
GROUP 5
MOTOR

3-Pole
LINE (SRC 1)
Yes
Yes
OFF
OFF
1.050 pu
1.050 pu
Yes
0.000 s
Yes
0.000 s
Yes
0.000 s
Bkr_Sts On(M5a)
OFF
OFF
1.050 pu
1.050 pu
1.050 pu
1.050 pu
0.000 s
0.000 s
Latched
Enabled
OFF
OFF
OFF
OFF
OFF
OFF
OFF

Enabled
LINE (SRC 1)
Phase to Ground
0.850 pu
Definite Time
10.00 s
0.100 pu
OFF
Self-reset
Enabled
Enabled
LINE (SRC 1)
Phase to Ground
0.800 pu
Definite Time
3.00 s
0.100 pu
OFF
Latched
Enabled
Enabled
LINE (SRC 1)
1.100 pu
3.00 s
1.00 s
OFF
Self-reset
Enabled

Fri Oct 14 17:14:31 2016 Version: 7.22 Settings (Enabled Features)

PAGE 22

QUICK CONNECT
QUICK CONNECT DEVICE
DEVICE DEFINITION
ORDER CODE: M60-J03-VKH-F8M-H5C-M6E-PXX
VERSION: 6.0X
DESCRIPTION: (NONE)
INTERFACE: COM2: 19200 N 8 1
ACCELERATION TIME [GROUP 5]
Function
Current
Time
Mode
Block
Target
Events

Enabled
6.00 x FLA
14.40 s
Definite Time
OFF
Latched
Enabled

THERMAL MODEL [GROUP 5]


Function
Curve
Thermal Model IEC Curve k Factor
IEC Curve Time Constant
Curve Effect
TD Multiplier
Bias K Factor
Cool Time Constant Running
Cool Time Constant Stopped
Hot/Cold Safe Stall Ratio
RTD Bias
RTD Bias Min
RTD Bias Center
RTD Bias Max
Start Inhibit Margin
Voltage Dependent Function
Voltage Dependent Min Motor Volts
Voltage Dependent Voltage Loss
Voltage Dependent Stall Current Min Volts
Voltage Dependent Safe Stall Time Min Volts
Voltage Dependent Accel Intersect Min Volts
Voltage Dependent Stall current @100% Volts
Voltage Dependent Safe Stall Time @100% Volts
Voltage Dependent Accel Intersect @100% Volts
Block
Target
Events

Enabled
Motor
1.10
45 min
Cutoff
7.00
6
15 min
30 min
0.75
Enabled
40 C
130 C
155 C
0%
Enabled
80 %
OFF
4.50 x FLA
12.0 sec
4.00 x FLA
6.00 x FLA
10.0 sec
5.00 x FLA
OFF
Latched
Enabled

AMP UNBALANCE [GROUP 5]


AMP UNBALANCE 1: Function
AMP UNBALANCE 1: Pickup
AMP UNBALANCE 1: Pickup Delay
AMP UNBALANCE 1: Reset Delay
AMP UNBALANCE 1: Block
AMP UNBALANCE 1: Targets
AMP UNBALANCE 1: Events
AMP UNBALANCE 2: Function
AMP UNBALANCE 2: Pickup
AMP UNBALANCE 2: Pickup Delay
AMP UNBALANCE 2: Reset Delay
AMP UNBALANCE 2: Block
AMP UNBALANCE 2: Targets
AMP UNBALANCE 2: Events

Enabled
15.0 %
10.00 s
0.00 s
OFF
Self-reset
Enabled
Enabled
20.0 %
5.00 s
0.00 s
OFF
Latched
Enabled

MECHANICAL JAM [GROUP 5]


Function
Pickup
Pickup Delay
Reset Delay
Block
Target
Events

Enabled
3.00 X FLA
2.50 s
0.00 s
OFF
Latched
Enabled

TWO-SPEED MOTOR
THERMAL MODEL [GROUP 5]
Speed2 Thermal Model Curve
Speed2 Thermal Model TD Multiplier
Speed2 Voltage Dependant Function

Motor
1.00
Disabled

Fri Oct 14 17:14:31 2016 Version: 7.22 Settings (Enabled Features)

PAGE 23

QUICK CONNECT
QUICK CONNECT DEVICE
DEVICE DEFINITION
ORDER CODE: M60-J03-VKH-F8M-H5C-M6E-PXX
VERSION: 6.0X
DESCRIPTION: (NONE)
INTERFACE: COM2: 19200 N 8 1
ACCELERATION TIME [GROUP 5]
Speed2 Acceleration Current
Speed2 Acceleration Time
Speed2 Acceleration Mode
Speed2 Acceleration Time Speed 1-2
Speed2 Acceleration Block

6.00 x FLA
10.00 s
Definite Time
10.00 s
OFF

UNDERCURRENT [GROUP 5]
Speed2 Undercurrent Start Block Delay
Speed2 Undercurrent Alarm Pickup
Speed2 Undercurrent Alarm Pickup Delay
Speed2 Undercurrent Trip Pickup
Speed2 Undercurrent Trip Pickup Delay
Speed2 Undercurrent Trip Reset Delay
Speed2 Undercurrent Block

0.50 s
0.70 x FLA
2.00 s
0.70 x FLA
1.00 s
1.00 s
OFF

PHASE CURRENT
PHASE DIRECTIONAL [GROUP 5]
PHASE DIR1: Function
PHASE DIR1: Source
PHASE DIR1: Block
PHASE DIR1: ECA
PHASE DIR1: Pol V Threshold
PHASE DIR1: Block when V Mem Exp
PHASE DIR1: Target
PHASE DIR1: Events

Enabled
LINE (SRC 1)
OFF
30 deg
0.700 pu
No
Latched
Enabled

GROUND CURRENT
GROUND IOC [GROUP 5]
GROUND IOC1: Function
GROUND IOC1: Source
GROUND IOC1: Pickup
GROUND IOC1: Delay
GROUND IOC1: Reset Delay
GROUND IOC1: Block
GROUND IOC1: Target
GROUND IOC1: Events
GROUND IOC2: Function
GROUND IOC2: Source
GROUND IOC2: Pickup
GROUND IOC2: Delay
GROUND IOC2: Reset Delay
GROUND IOC2: Block
GROUND IOC2: Target
GROUND IOC2: Events

Enabled
LINE (SRC 1)
0.100 pu
0.20 s
0.00 s
OFF
Self-reset
Enabled
Enabled
LINE (SRC 1)
0.150 pu
0.00 s
0.00 s
OFF
Latched
Enabled

BREAKER FAILURE [GROUP 5]


BF1: Function
BF1: Mode
BF1: Source
BF1: Current Supervision
BF1: Use Seal-In
BF1: Three Pole Initiate
BF1: Block
BF1: Phase Current Supv Pickup
BF1: Neutral Current Supv Pickup
BF1: Use Timer 1
BF1: Timer 1 Pickup Delay
BF1: Use Timer 2
BF1: Timer 2 Pickup Delay
BF1: Use Timer 3
BF1: Timer 3 Pickup Delay
BF1: Breaker Pos1 Phase A/3P
BF1: Breaker Pos2 Phase A/3P
BF1: Breaker Test On
BF1: Phase Current HiSet Pickup
BF1: Neutral Current HiSet Pickup
BF1: Phase Current LoSet Pickup
BF1: Neutral Current LoSet Pickup

Enabled
3-Pole
LINE (SRC 1)
Yes
Yes
OFF
OFF
1.050 pu
1.050 pu
Yes
0.000 s
Yes
0.000 s
Yes
0.000 s
Bkr_Sts On(M5a)
OFF
OFF
1.050 pu
1.050 pu
1.050 pu
1.050 pu

Fri Oct 14 17:14:31 2016 Version: 7.22 Settings (Enabled Features)

PAGE 24

QUICK CONNECT
QUICK CONNECT DEVICE
DEVICE DEFINITION
ORDER CODE: M60-J03-VKH-F8M-H5C-M6E-PXX
VERSION: 6.0X
DESCRIPTION: (NONE)
INTERFACE: COM2: 19200 N 8 1
BREAKER FAILURE [GROUP 5] (continued from last page)
BF1: LoSet Time Delay
BF1: Trip Dropout Delay
BF1: Target
BF1: Events
BF1: Phase A Initiate
BF1: Phase B Initiate
BF1: Phase C Initiate
BF1: Breaker Pos1 Phase B
BF1: Breaker Pos1 Phase C
BF1: Breaker Pos2 Phase B
BF1: Breaker Pos2 Phase C
VOLTAGE ELEMENTS
PHASE UV [GROUP 5]
PHASE UV1: Function
PHASE UV1: Signal Source
PHASE UV1: Mode
PHASE UV1: Pickup
PHASE UV1: Curve
PHASE UV1: Delay
PHASE UV1: Minimum Voltage
PHASE UV1: Block
PHASE UV1: Target
PHASE UV1: Events
PHASE UV2: Function
PHASE UV2: Signal Source
PHASE UV2: Mode
PHASE UV2: Pickup
PHASE UV2: Curve
PHASE UV2: Delay
PHASE UV2: Minimum Voltage
PHASE UV2: Block
PHASE UV2: Target
PHASE UV2: Events
PHASE OV [GROUP 5]
PHASE OV1: Function
PHASE OV1: Source
PHASE OV1: Pickup
PHASE OV1: Delay
PHASE OV1: Reset Delay
PHASE OV1: Block
PHASE OV1: Target
PHASE OV1: Events
GROUP 6
MOTOR
ACCELERATION TIME [GROUP 6]
Function
Current
Time
Mode
Block
Target
Events
THERMAL MODEL [GROUP 6]
Function
Curve
Thermal Model IEC Curve k Factor
IEC Curve Time Constant
Curve Effect
TD Multiplier
Bias K Factor
Cool Time Constant Running
Cool Time Constant Stopped
Hot/Cold Safe Stall Ratio
RTD Bias

0.000 s
0.000 s
Latched
Enabled
OFF
OFF
OFF
OFF
OFF
OFF
OFF

Enabled
LINE (SRC 1)
Phase to Ground
0.850 pu
Definite Time
10.00 s
0.100 pu
OFF
Self-reset
Enabled
Enabled
LINE (SRC 1)
Phase to Ground
0.800 pu
Definite Time
3.00 s
0.100 pu
OFF
Latched
Enabled
Enabled
LINE (SRC 1)
1.100 pu
3.00 s
1.00 s
OFF
Self-reset
Enabled

Enabled
6.00 x FLA
14.40 s
Definite Time
OFF
Latched
Enabled
Enabled
Motor
1.10
45 min
Cutoff
7.00
6
15 min
30 min
0.75
Enabled

Fri Oct 14 17:14:31 2016 Version: 7.22 Settings (Enabled Features)

PAGE 25

QUICK CONNECT
QUICK CONNECT DEVICE
DEVICE DEFINITION
ORDER CODE: M60-J03-VKH-F8M-H5C-M6E-PXX
VERSION: 6.0X
DESCRIPTION: (NONE)
INTERFACE: COM2: 19200 N 8 1
THERMAL MODEL [GROUP 6] (continued from last page)
RTD Bias Min
RTD Bias Center
RTD Bias Max
Start Inhibit Margin
Voltage Dependent Function
Voltage Dependent Min Motor Volts
Voltage Dependent Voltage Loss
Voltage Dependent Stall Current Min Volts
Voltage Dependent Safe Stall Time Min Volts
Voltage Dependent Accel Intersect Min Volts
Voltage Dependent Stall current @100% Volts
Voltage Dependent Safe Stall Time @100% Volts
Voltage Dependent Accel Intersect @100% Volts
Block
Target
Events

40 C
130 C
155 C
0%
Enabled
80 %
OFF
4.50 x FLA
12.0 sec
4.00 x FLA
6.00 x FLA
10.0 sec
5.00 x FLA
OFF
Latched
Enabled

AMP UNBALANCE [GROUP 6]


AMP UNBALANCE 1: Function
AMP UNBALANCE 1: Pickup
AMP UNBALANCE 1: Pickup Delay
AMP UNBALANCE 1: Reset Delay
AMP UNBALANCE 1: Block
AMP UNBALANCE 1: Targets
AMP UNBALANCE 1: Events
AMP UNBALANCE 2: Function
AMP UNBALANCE 2: Pickup
AMP UNBALANCE 2: Pickup Delay
AMP UNBALANCE 2: Reset Delay
AMP UNBALANCE 2: Block
AMP UNBALANCE 2: Targets
AMP UNBALANCE 2: Events

Enabled
15.0 %
10.00 s
0.00 s
OFF
Self-reset
Enabled
Enabled
20.0 %
5.00 s
0.00 s
OFF
Latched
Enabled

MECHANICAL JAM [GROUP 6]


Function
Pickup
Pickup Delay
Reset Delay
Block
Target
Events

Enabled
3.00 X FLA
2.50 s
0.00 s
OFF
Latched
Enabled

TWO-SPEED MOTOR
THERMAL MODEL [GROUP 6]
Speed2 Thermal Model Curve
Speed2 Thermal Model TD Multiplier
Speed2 Voltage Dependant Function

Motor
1.00
Disabled

ACCELERATION TIME [GROUP 6]


Speed2 Acceleration Current
Speed2 Acceleration Time
Speed2 Acceleration Mode
Speed2 Acceleration Time Speed 1-2
Speed2 Acceleration Block

6.00 x FLA
10.00 s
Definite Time
10.00 s
OFF

UNDERCURRENT [GROUP 6]
Speed2 Undercurrent Start Block Delay
Speed2 Undercurrent Alarm Pickup
Speed2 Undercurrent Alarm Pickup Delay
Speed2 Undercurrent Trip Pickup
Speed2 Undercurrent Trip Pickup Delay
Speed2 Undercurrent Trip Reset Delay
Speed2 Undercurrent Block

0.50 s
0.70 x FLA
2.00 s
0.70 x FLA
1.00 s
1.00 s
OFF

PHASE CURRENT
PHASE DIRECTIONAL [GROUP 6]
PHASE DIR1: Function
PHASE DIR1: Source

Enabled
LINE (SRC 1)

Fri Oct 14 17:14:31 2016 Version: 7.22 Settings (Enabled Features)

PAGE 26

QUICK CONNECT
QUICK CONNECT DEVICE
DEVICE DEFINITION
ORDER CODE: M60-J03-VKH-F8M-H5C-M6E-PXX
VERSION: 6.0X
DESCRIPTION: (NONE)
INTERFACE: COM2: 19200 N 8 1
PHASE DIRECTIONAL [GROUP 6] (continued from last page)
PHASE DIR1: Block
PHASE DIR1: ECA
PHASE DIR1: Pol V Threshold
PHASE DIR1: Block when V Mem Exp
PHASE DIR1: Target
PHASE DIR1: Events
GROUND CURRENT
GROUND IOC [GROUP 6]
GROUND IOC1: Function
GROUND IOC1: Source
GROUND IOC1: Pickup
GROUND IOC1: Delay
GROUND IOC1: Reset Delay
GROUND IOC1: Block
GROUND IOC1: Target
GROUND IOC1: Events
GROUND IOC2: Function
GROUND IOC2: Source
GROUND IOC2: Pickup
GROUND IOC2: Delay
GROUND IOC2: Reset Delay
GROUND IOC2: Block
GROUND IOC2: Target
GROUND IOC2: Events
BREAKER FAILURE [GROUP 6]
BF1: Function
BF1: Mode
BF1: Source
BF1: Current Supervision
BF1: Use Seal-In
BF1: Three Pole Initiate
BF1: Block
BF1: Phase Current Supv Pickup
BF1: Neutral Current Supv Pickup
BF1: Use Timer 1
BF1: Timer 1 Pickup Delay
BF1: Use Timer 2
BF1: Timer 2 Pickup Delay
BF1: Use Timer 3
BF1: Timer 3 Pickup Delay
BF1: Breaker Pos1 Phase A/3P
BF1: Breaker Pos2 Phase A/3P
BF1: Breaker Test On
BF1: Phase Current HiSet Pickup
BF1: Neutral Current HiSet Pickup
BF1: Phase Current LoSet Pickup
BF1: Neutral Current LoSet Pickup
BF1: LoSet Time Delay
BF1: Trip Dropout Delay
BF1: Target
BF1: Events
BF1: Phase A Initiate
BF1: Phase B Initiate
BF1: Phase C Initiate
BF1: Breaker Pos1 Phase B
BF1: Breaker Pos1 Phase C
BF1: Breaker Pos2 Phase B
BF1: Breaker Pos2 Phase C
VOLTAGE ELEMENTS
PHASE UV [GROUP 6]
PHASE UV1: Function
PHASE UV1: Signal Source
PHASE UV1: Mode
PHASE UV1: Pickup
PHASE UV1: Curve

OFF
30 deg
0.700 pu
No
Latched
Enabled

Enabled
LINE (SRC 1)
0.100 pu
0.20 s
0.00 s
OFF
Self-reset
Enabled
Enabled
LINE (SRC 1)
0.150 pu
0.00 s
0.00 s
OFF
Latched
Enabled
Enabled
3-Pole
LINE (SRC 1)
Yes
Yes
OFF
OFF
1.050 pu
1.050 pu
Yes
0.000 s
Yes
0.000 s
Yes
0.000 s
Bkr_Sts On(M5a)
OFF
OFF
1.050 pu
1.050 pu
1.050 pu
1.050 pu
0.000 s
0.000 s
Latched
Enabled
OFF
OFF
OFF
OFF
OFF
OFF
OFF

Enabled
LINE (SRC 1)
Phase to Ground
0.850 pu
Definite Time

Fri Oct 14 17:14:31 2016 Version: 7.22 Settings (Enabled Features)

PAGE 27

QUICK CONNECT
QUICK CONNECT DEVICE
DEVICE DEFINITION
ORDER CODE: M60-J03-VKH-F8M-H5C-M6E-PXX
VERSION: 6.0X
DESCRIPTION: (NONE)
INTERFACE: COM2: 19200 N 8 1
PHASE UV [GROUP 6] (continued from last page)
PHASE UV1: Delay
PHASE UV1: Minimum Voltage
PHASE UV1: Block
PHASE UV1: Target
PHASE UV1: Events
PHASE UV2: Function
PHASE UV2: Signal Source
PHASE UV2: Mode
PHASE UV2: Pickup
PHASE UV2: Curve
PHASE UV2: Delay
PHASE UV2: Minimum Voltage
PHASE UV2: Block
PHASE UV2: Target
PHASE UV2: Events

10.00 s
0.100 pu
OFF
Self-reset
Enabled
Enabled
LINE (SRC 1)
Phase to Ground
0.800 pu
Definite Time
3.00 s
0.100 pu
OFF
Latched
Enabled

PHASE OV [GROUP 6]
PHASE OV1: Function
PHASE OV1: Source
PHASE OV1: Pickup
PHASE OV1: Delay
PHASE OV1: Reset Delay
PHASE OV1: Block
PHASE OV1: Target
PHASE OV1: Events

Enabled
LINE (SRC 1)
1.100 pu
3.00 s
1.00 s
OFF
Self-reset
Enabled

CONTROL ELEMENTS
TRIP BUS
Trip Bus 1 Function
Trip Bus 1 Block
Trip Bus 1 Pickup Delay
Trip Bus 1 Reset Delay
Trip Bus 1 Input 1
Trip Bus 1 Input 2
Trip Bus 1 Input 3
Trip Bus 1 Input 4
Trip Bus 1 Input 5
Trip Bus 1 Input 6
Trip Bus 1 Input 7
Trip Bus 1 Input 8
Trip Bus 1 Input 9
Trip Bus 1 Input 10
Trip Bus 1 Input 11
Trip Bus 1 Input 12
Trip Bus 1 Input 13
Trip Bus 1 Input 14
Trip Bus 1 Input 15
Trip Bus 1 Input 16
Trip Bus 1 Latching
Trip Bus 1 Reset
Trip Bus 1 Target
Trip Bus 1 Events
Trip Bus 2 Function
Trip Bus 2 Block
Trip Bus 2 Pickup Delay
Trip Bus 2 Reset Delay
Trip Bus 2 Input 1
Trip Bus 2 Input 2
Trip Bus 2 Input 3
Trip Bus 2 Input 4
Trip Bus 2 Input 5
Trip Bus 2 Input 6
Trip Bus 2 Input 7
Trip Bus 2 Input 8
Trip Bus 2 Input 9
Trip Bus 2 Input 10
Trip Bus 2 Input 11
Trip Bus 2 Input 12

Enabled
OFF
0.00 s
0.03 s
MOTOR ACCEL TIME OP
MOTOR THERMAL OP
OFF
AMP UNBALANCE 2 OP
MECHANICAL JAM OP
STATOR DIFF OP
PHASE UV2 OP
PHASE OV1 OP
PH DIR1 BLK
BKR FAIL 1 TRIP OP
OFF
PHASE IOC1 OP
GROUND IOC1 OP
OFF
RTD Trip On (VO62)
OFF
Enabled
OFF
Self-reset
Enabled
Enabled
OFF
0.00 s
0.00 s
MOTOR THERMAL PKP
Start Super. On (VO63)
MOTOR OVERLOAD
AMP UNBALANCE 1 OP
STATOR DIFF PKP A
STATOR DIFF PKP B
STATOR DIFF PKP C
PHASE UV1 OP
OFF
RTD Alarm On (VO61)
OFF
OFF

Fri Oct 14 17:14:31 2016 Version: 7.22 Settings (Enabled Features)

PAGE 28

QUICK CONNECT
QUICK CONNECT DEVICE
DEVICE DEFINITION
ORDER CODE: M60-J03-VKH-F8M-H5C-M6E-PXX
VERSION: 6.0X
DESCRIPTION: (NONE)
INTERFACE: COM2: 19200 N 8 1
TRIP BUS (continued from last page)
Trip Bus 2 Input 13
Trip Bus 2 Input 14
Trip Bus 2 Input 15
Trip Bus 2 Input 16
Trip Bus 2 Latching
Trip Bus 2 Reset
Trip Bus 2 Target
Trip Bus 2 Events

OFF
OFF
OFF
OFF
Disabled
OFF
Self-reset
Enabled

MONITORING ELEMENTS
VT FUSE FAILURE
VT FUSE FAILURE 1: Function
VT FUSE FAILURE 1: Neutral Wire Open Detection
VT FUSE FAILURE 1: 3rd Harmonic Pickup

Enabled
Disabled
0.100 pu

START SUPERVISION
RESTART DELAY
Function
Min Time
Block
Target
Events

Enabled
5 sec
OFF
Self-reset
Enabled

INPUTS/OUTPUTS
CONTACT INPUTS
[M5A] Contact Input 1 ID
[M5A] Contact Input 1 Debounce Time
[M5A] Contact Input 1 Events
[M5C] Contact Input 2 ID
[M5C] Contact Input 2 Debounce Time
[M5C] Contact Input 2 Events
[M6A] Contact Input 3 ID
[M6A] Contact Input 3 Debounce Time
[M6A] Contact Input 3 Events
[M6C] Contact Input 4 ID
[M6C] Contact Input 4 Debounce Time
[M6C] Contact Input 4 Events
[M7A] Contact Input 5 ID
[M7A] Contact Input 5 Debounce Time
[M7A] Contact Input 5 Events
[M7C] Contact Input 6 ID
[M7C] Contact Input 6 Debounce Time
[M7C] Contact Input 6 Events
[M8A] Contact Input 7 ID
[M8A] Contact Input 7 Debounce Time
[M8A] Contact Input 7 Events
[M8C] Contact Input 8 ID
[M8C] Contact Input 8 Debounce Time
[M8C] Contact Input 8 Events

Bkr_Sts
2.0 ms
Enabled
Cont Ip 2
2.0 ms
Disabled
Cont Ip 3
2.0 ms
Disabled
Cont Ip 4
2.0 ms
Disabled
Cont. Close
2.0 ms
Enabled
Earth. Close
2.0 ms
Enabled
MCBS Faulty
2.0 ms
Enabled
Cont.Open
2.0 ms
Enabled

CONTACT INPUT THRESHOLDS


Bkr_Sts, Cont Ip 2, Cont Ip 3, Cont Ip 4(M5a, M5c, M6a, M6c)
Cont. Close, Earth. Close, MCBS Faulty, Cont.Open(M7a, M7c, M8a, M8c)

33 Vdc
33 Vdc

CONTACT OUTPUTS
[M1] Contact Output 1 ID
[M1] Contact Output 1 Operate
[M1] Contact Output 1 Seal-In
[M1] Contact Output 1 Events
[M2] Contact Output 2 ID
[M2] Contact Output 2 Operate
[M2] Contact Output 2 Seal-In
[M2] Contact Output 2 Events
[M3] Contact Output 3 ID
[M3] Contact Output 3 Operate
[M3] Contact Output 3 Seal-In
[M3] Contact Output 3 Events
[M4] Contact Output 4 ID

Breaker Trip
TRIPBUS 1 OP
OFF
Enabled
Motor Alarm
TRIPBUS 2 OP
OFF
Enabled
Trip To PLC
TRIPBUS 1 OP
OFF
Enabled
Start Block

Fri Oct 14 17:14:31 2016 Version: 7.22 Settings (Enabled Features)

PAGE 29

QUICK CONNECT
QUICK CONNECT DEVICE
DEVICE DEFINITION
ORDER CODE: M60-J03-VKH-F8M-H5C-M6E-PXX
VERSION: 6.0X
DESCRIPTION: (NONE)
INTERFACE: COM2: 19200 N 8 1
CONTACT OUTPUTS (continued from last page)
[M4] Contact Output 4 Operate
[M4] Contact Output 4 Seal-In
[M4] Contact Output 4 Events

MOTOR START INHIBIT


OFF
Enabled

VIRTUAL OUTPUTS
Virtual Output 1 ID
Virtual Output 1 Events
Virtual Output 2 ID
Virtual Output 2 Events
Virtual Output 61 ID
Virtual Output 61 Events
Virtual Output 62 ID
Virtual Output 62 Events
Virtual Output 63 ID
Virtual Output 63 Events
Virtual Output 64 ID
Virtual Output 64 Events

Virt Op 1
Enabled
Virt Op 2
Disabled
RTD Alarm
Enabled
RTD Trip
Enabled
Start Super.
Enabled
Osc Trigger
Enabled

REMOTE DEVICES
Remote Device 1 ID
Remote Device 1 ETYPE APPID
Remote Device 1 DATASET
Remote Device 2 ID
Remote Device 2 ETYPE APPID
Remote Device 2 DATASET
Remote Device 3 ID
Remote Device 3 ETYPE APPID
Remote Device 3 DATASET
Remote Device 4 ID
Remote Device 4 ETYPE APPID
Remote Device 4 DATASET
Remote Device 5 ID
Remote Device 5 ETYPE APPID
Remote Device 5 DATASET
Remote Device 6 ID
Remote Device 6 ETYPE APPID
Remote Device 6 DATASET
Remote Device 7 ID
Remote Device 7 ETYPE APPID
Remote Device 7 DATASET
Remote Device 8 ID
Remote Device 8 ETYPE APPID
Remote Device 8 DATASET
Remote Device 9 ID
Remote Device 9 ETYPE APPID
Remote Device 9 DATASET
Remote Device 10 ID
Remote Device 10 ETYPE APPID
Remote Device 10 DATASET
Remote Device 11 ID
Remote Device 11 ETYPE APPID
Remote Device 11 DATASET
Remote Device 12 ID
Remote Device 12 ETYPE APPID
Remote Device 12 DATASET
Remote Device 13 ID
Remote Device 13 ETYPE APPID
Remote Device 13 DATASET
Remote Device 14 ID
Remote Device 14 ETYPE APPID
Remote Device 14 DATASET
Remote Device 15 ID
Remote Device 15 ETYPE APPID
Remote Device 15 DATASET
Remote Device 16 ID
Remote Device 16 ETYPE APPID
Remote Device 16 DATASET

Remote Device 1
0
Fixed
Remote Device 2
0
Fixed
Remote Device 3
0
Fixed
Remote Device 4
0
Fixed
Remote Device 5
0
Fixed
Remote Device 6
0
Fixed
Remote Device 7
0
Fixed
Remote Device 8
0
Fixed
Remote Device 9
0
Fixed
Remote Device 10
0
Fixed
Remote Device 11
0
Fixed
Remote Device 12
0
Fixed
Remote Device 13
0
Fixed
Remote Device 14
0
Fixed
Remote Device 15
0
Fixed
Remote Device 16
0
Fixed

Fri Oct 14 17:14:31 2016 Version: 7.22 Settings (Enabled Features)

PAGE 30

QUICK CONNECT
QUICK CONNECT DEVICE
DEVICE DEFINITION
ORDER CODE: M60-J03-VKH-F8M-H5C-M6E-PXX
VERSION: 6.0X
DESCRIPTION: (NONE)
INTERFACE: COM2: 19200 N 8 1
IEC 61850 GOOSE ANALOGS INPUTS
IEC61850 GOOSE Analog Input 1 Default Value
IEC61850 GOOSE Analog Input 1 Mode
IEC61850 GOOSE Analog Input 1 Units
IEC61850 GOOSE Analog Input 1 PU Base
IEC61850 GOOSE Analog Input 2 Default Value
IEC61850 GOOSE Analog Input 2 Mode
IEC61850 GOOSE Analog Input 2 Units
IEC61850 GOOSE Analog Input 2 PU Base
IEC61850 GOOSE Analog Input 3 Default Value
IEC61850 GOOSE Analog Input 3 Mode
IEC61850 GOOSE Analog Input 3 Units
IEC61850 GOOSE Analog Input 3 PU Base
IEC61850 GOOSE Analog Input 4 Default Value
IEC61850 GOOSE Analog Input 4 Mode
IEC61850 GOOSE Analog Input 4 Units
IEC61850 GOOSE Analog Input 4 PU Base
IEC61850 GOOSE Analog Input 5 Default Value
IEC61850 GOOSE Analog Input 5 Mode
IEC61850 GOOSE Analog Input 5 Units
IEC61850 GOOSE Analog Input 5 PU Base
IEC61850 GOOSE Analog Input 6 Default Value
IEC61850 GOOSE Analog Input 6 Mode
IEC61850 GOOSE Analog Input 6 Units
IEC61850 GOOSE Analog Input 6 PU Base
IEC61850 GOOSE Analog Input 7 Default Value
IEC61850 GOOSE Analog Input 7 Mode
IEC61850 GOOSE Analog Input 7 Units
IEC61850 GOOSE Analog Input 7 PU Base
IEC61850 GOOSE Analog Input 8 Default Value
IEC61850 GOOSE Analog Input 8 Mode
IEC61850 GOOSE Analog Input 8 Units
IEC61850 GOOSE Analog Input 8 PU Base
IEC61850 GOOSE Analog Input 9 Default Value
IEC61850 GOOSE Analog Input 9 Mode
IEC61850 GOOSE Analog Input 9 Units
IEC61850 GOOSE Analog Input 9 PU Base
IEC61850 GOOSE Analog Input 10 Default Value
IEC61850 GOOSE Analog Input 10 Mode
IEC61850 GOOSE Analog Input 10 Units
IEC61850 GOOSE Analog Input 10 PU Base
IEC61850 GOOSE Analog Input 11 Default Value
IEC61850 GOOSE Analog Input 11 Mode
IEC61850 GOOSE Analog Input 11 Units
IEC61850 GOOSE Analog Input 11 PU Base
IEC61850 GOOSE Analog Input 12 Default Value
IEC61850 GOOSE Analog Input 12 Mode
IEC61850 GOOSE Analog Input 12 Units
IEC61850 GOOSE Analog Input 12 PU Base
IEC61850 GOOSE Analog Input 13 Default Value
IEC61850 GOOSE Analog Input 13 Mode
IEC61850 GOOSE Analog Input 13 Units
IEC61850 GOOSE Analog Input 13 PU Base
IEC61850 GOOSE Analog Input 14 Default Value
IEC61850 GOOSE Analog Input 14 Mode
IEC61850 GOOSE Analog Input 14 Units
IEC61850 GOOSE Analog Input 14 PU Base
IEC61850 GOOSE Analog Input 15 Default Value
IEC61850 GOOSE Analog Input 15 Mode
IEC61850 GOOSE Analog Input 15 Units
IEC61850 GOOSE Analog Input 15 PU Base
IEC61850 GOOSE Analog Input 16 Default Value
IEC61850 GOOSE Analog Input 16 Mode
IEC61850 GOOSE Analog Input 16 Units
IEC61850 GOOSE Analog Input 16 PU Base
IEC61850 GOOSE Analog Input 17 Default Value
IEC61850 GOOSE Analog Input 17 Mode
IEC61850 GOOSE Analog Input 17 Units
IEC61850 GOOSE Analog Input 17 PU Base

1000.000
Default Value
1.000
1000.000
Default Value
1.000
1000.000
Default Value
1.000
1000.000
Default Value
1.000
1000.000
Default Value
1.000
1000.000
Default Value
1.000
1000.000
Default Value
1.000
1000.000
Default Value
1.000
1000.000
Default Value
1.000
1000.000
Default Value
1.000
1000.000
Default Value
1.000
1000.000
Default Value
1.000
1000.000
Default Value
1.000
1000.000
Default Value
1.000
1000.000
Default Value
1.000
1000.000
Default Value
1.000
1000.000
Default Value
1.000

Fri Oct 14 17:14:31 2016 Version: 7.22 Settings (Enabled Features)

PAGE 31

QUICK CONNECT
QUICK CONNECT DEVICE
DEVICE DEFINITION
ORDER CODE: M60-J03-VKH-F8M-H5C-M6E-PXX
VERSION: 6.0X
DESCRIPTION: (NONE)
INTERFACE: COM2: 19200 N 8 1
IEC 61850 GOOSE ANALOGS INPUTS (continued from last page)
IEC61850 GOOSE Analog Input 18 Default Value
IEC61850 GOOSE Analog Input 18 Mode
IEC61850 GOOSE Analog Input 18 Units
IEC61850 GOOSE Analog Input 18 PU Base
IEC61850 GOOSE Analog Input 19 Default Value
IEC61850 GOOSE Analog Input 19 Mode
IEC61850 GOOSE Analog Input 19 Units
IEC61850 GOOSE Analog Input 19 PU Base
IEC61850 GOOSE Analog Input 20 Default Value
IEC61850 GOOSE Analog Input 20 Mode
IEC61850 GOOSE Analog Input 20 Units
IEC61850 GOOSE Analog Input 20 PU Base
IEC61850 GOOSE Analog Input 21 Default Value
IEC61850 GOOSE Analog Input 21 Mode
IEC61850 GOOSE Analog Input 21 Units
IEC61850 GOOSE Analog Input 21 PU Base
IEC61850 GOOSE Analog Input 22 Default Value
IEC61850 GOOSE Analog Input 22 Mode
IEC61850 GOOSE Analog Input 22 Units
IEC61850 GOOSE Analog Input 22 PU Base
IEC61850 GOOSE Analog Input 23 Default Value
IEC61850 GOOSE Analog Input 23 Mode
IEC61850 GOOSE Analog Input 23 Units
IEC61850 GOOSE Analog Input 23 PU Base
IEC61850 GOOSE Analog Input 24 Default Value
IEC61850 GOOSE Analog Input 24 Mode
IEC61850 GOOSE Analog Input 24 Units
IEC61850 GOOSE Analog Input 24 PU Base
IEC61850 GOOSE Analog Input 25 Default Value
IEC61850 GOOSE Analog Input 25 Mode
IEC61850 GOOSE Analog Input 25 Units
IEC61850 GOOSE Analog Input 25 PU Base
IEC61850 GOOSE Analog Input 26 Default Value
IEC61850 GOOSE Analog Input 26 Mode
IEC61850 GOOSE Analog Input 26 Units
IEC61850 GOOSE Analog Input 26 PU Base
IEC61850 GOOSE Analog Input 27 Default Value
IEC61850 GOOSE Analog Input 27 Mode
IEC61850 GOOSE Analog Input 27 Units
IEC61850 GOOSE Analog Input 27 PU Base
IEC61850 GOOSE Analog Input 28 Default Value
IEC61850 GOOSE Analog Input 28 Mode
IEC61850 GOOSE Analog Input 28 Units
IEC61850 GOOSE Analog Input 28 PU Base
IEC61850 GOOSE Analog Input 29 Default Value
IEC61850 GOOSE Analog Input 29 Mode
IEC61850 GOOSE Analog Input 29 Units
IEC61850 GOOSE Analog Input 29 PU Base
IEC61850 GOOSE Analog Input 30 Default Value
IEC61850 GOOSE Analog Input 30 Mode
IEC61850 GOOSE Analog Input 30 Units
IEC61850 GOOSE Analog Input 30 PU Base
IEC61850 GOOSE Analog Input 31 Default Value
IEC61850 GOOSE Analog Input 31 Mode
IEC61850 GOOSE Analog Input 31 Units
IEC61850 GOOSE Analog Input 31 PU Base
IEC61850 GOOSE Analog Input 32 Default Value
IEC61850 GOOSE Analog Input 32 Mode
IEC61850 GOOSE Analog Input 32 Units
IEC61850 GOOSE Analog Input 32 PU Base
IEC 61850 GOOSE UINTEGERS INPUTS
IEC61850 GOOSE UInteger Input 1 Default Value
IEC61850 GOOSE UInteger Input 1 Mode
IEC61850 GOOSE UInteger Input 2 Default Value
IEC61850 GOOSE UInteger Input 2 Mode
IEC61850 GOOSE UInteger Input 3 Default Value
IEC61850 GOOSE UInteger Input 3 Mode

1000.000
Default Value
1.000
1000.000
Default Value
1.000
1000.000
Default Value
1.000
1000.000
Default Value
1.000
1000.000
Default Value
1.000
1000.000
Default Value
1.000
1000.000
Default Value
1.000
1000.000
Default Value
1.000
1000.000
Default Value
1.000
1000.000
Default Value
1.000
1000.000
Default Value
1.000
1000.000
Default Value
1.000
1000.000
Default Value
1.000
1000.000
Default Value
1.000
1000.000
Default Value
1.000
1000
Default Value
1000
Default Value
1000
Default Value

Fri Oct 14 17:14:31 2016 Version: 7.22 Settings (Enabled Features)

PAGE 32

QUICK CONNECT
QUICK CONNECT DEVICE
DEVICE DEFINITION
ORDER CODE: M60-J03-VKH-F8M-H5C-M6E-PXX
VERSION: 6.0X
DESCRIPTION: (NONE)
INTERFACE: COM2: 19200 N 8 1
IEC 61850 GOOSE UINTEGERS INPUTS (continued from last page)
IEC61850 GOOSE UInteger Input 4 Default Value
IEC61850 GOOSE UInteger Input 4 Mode
IEC61850 GOOSE UInteger Input 5 Default Value
IEC61850 GOOSE UInteger Input 5 Mode
IEC61850 GOOSE UInteger Input 6 Default Value
IEC61850 GOOSE UInteger Input 6 Mode
IEC61850 GOOSE UInteger Input 7 Default Value
IEC61850 GOOSE UInteger Input 7 Mode
IEC61850 GOOSE UInteger Input 8 Default Value
IEC61850 GOOSE UInteger Input 8 Mode
IEC61850 GOOSE UInteger Input 9 Default Value
IEC61850 GOOSE UInteger Input 9 Mode
IEC61850 GOOSE UInteger Input 10 Default Value
IEC61850 GOOSE UInteger Input 10 Mode
IEC61850 GOOSE UInteger Input 11 Default Value
IEC61850 GOOSE UInteger Input 11 Mode
IEC61850 GOOSE UInteger Input 12 Default Value
IEC61850 GOOSE UInteger Input 12 Mode
IEC61850 GOOSE UInteger Input 13 Default Value
IEC61850 GOOSE UInteger Input 13 Mode
IEC61850 GOOSE UInteger Input 14 Default Value
IEC61850 GOOSE UInteger Input 14 Mode
IEC61850 GOOSE UInteger Input 15 Default Value
IEC61850 GOOSE UInteger Input 15 Mode
IEC61850 GOOSE UInteger Input 16 Default Value
IEC61850 GOOSE UInteger Input 16 Mode
TRANSDUCER I/O
RTD INPUTS
[H1] RTD Input 1 Function
[H1] RTD Input 1 ID
[H1] RTD Input 1 Type
[H1] RTD Input 1 Application
[H1] RTD Input 1 Alarm Temperature
[H1] RTD Input 1 Alarm Pickup Delay
[H1] RTD Input 1 Trip Temperature
[H1] RTD Input 1 Trip Pickup Delay
[H1] RTD Input 1 Trip Reset Delay
[H1] RTD Input 1 Trip Voting
[H1] RTD Input 1 Open
[H1] RTD Input 1 Block
[H1] RTD Input 1 Target
[H1] RTD Input 1 Events
[H2] RTD Input 2 Function
[H2] RTD Input 2 ID
[H2] RTD Input 2 Type
[H2] RTD Input 2 Application
[H2] RTD Input 2 Alarm Temperature
[H2] RTD Input 2 Alarm Pickup Delay
[H2] RTD Input 2 Trip Temperature
[H2] RTD Input 2 Trip Pickup Delay
[H2] RTD Input 2 Trip Reset Delay
[H2] RTD Input 2 Trip Voting
[H2] RTD Input 2 Open
[H2] RTD Input 2 Block
[H2] RTD Input 2 Target
[H2] RTD Input 2 Events
[H3] RTD Input 3 Function
[H3] RTD Input 3 ID
[H3] RTD Input 3 Type
[H3] RTD Input 3 Application
[H3] RTD Input 3 Alarm Temperature
[H3] RTD Input 3 Alarm Pickup Delay
[H3] RTD Input 3 Trip Temperature
[H3] RTD Input 3 Trip Pickup Delay
[H3] RTD Input 3 Trip Reset Delay
[H3] RTD Input 3 Trip Voting
[H3] RTD Input 3 Open

1000
Default Value
1000
Default Value
1000
Default Value
1000
Default Value
1000
Default Value
1000
Default Value
1000
Default Value
1000
Default Value
1000
Default Value
1000
Default Value
1000
Default Value
1000
Default Value
1000
Default Value

Enabled
Stator1
100 Ohm Platinum
Stator
130 C
5.00 s
155 C
5.00 s
0.00 s
RTD Ip 2
Alarm
OFF
Latched
Enabled
Enabled
Stator2
100 Ohm Platinum
Stator
130 C
5.00 s
155 C
5.00 s
0.00 s
RTD Ip 3
Alarm
OFF
Latched
Enabled
Enabled
Stator3
100 Ohm Platinum
Stator
130 C
5.00 s
155 C
5.00 s
0.00 s
RTD Ip 1
Alarm

Fri Oct 14 17:14:31 2016 Version: 7.22 Settings (Enabled Features)

PAGE 33

QUICK CONNECT
QUICK CONNECT DEVICE
DEVICE DEFINITION
ORDER CODE: M60-J03-VKH-F8M-H5C-M6E-PXX
VERSION: 6.0X
DESCRIPTION: (NONE)
INTERFACE: COM2: 19200 N 8 1
RTD INPUTS (continued from last page)
[H3] RTD Input 3 Block
[H3] RTD Input 3 Target
[H3] RTD Input 3 Events
[H5] RTD Input 5 Function
[H5] RTD Input 5 ID
[H5] RTD Input 5 Type
[H5] RTD Input 5 Application
[H5] RTD Input 5 Alarm Temperature
[H5] RTD Input 5 Alarm Pickup Delay
[H5] RTD Input 5 Trip Temperature
[H5] RTD Input 5 Trip Pickup Delay
[H5] RTD Input 5 Trip Reset Delay
[H5] RTD Input 5 Trip Voting
[H5] RTD Input 5 Open
[H5] RTD Input 5 Block
[H5] RTD Input 5 Target
[H5] RTD Input 5 Events
[H6] RTD Input 6 Function
[H6] RTD Input 6 ID
[H6] RTD Input 6 Type
[H6] RTD Input 6 Application
[H6] RTD Input 6 Alarm Temperature
[H6] RTD Input 6 Alarm Pickup Delay
[H6] RTD Input 6 Trip Temperature
[H6] RTD Input 6 Trip Pickup Delay
[H6] RTD Input 6 Trip Reset Delay
[H6] RTD Input 6 Trip Voting
[H6] RTD Input 6 Open
[H6] RTD Input 6 Block
[H6] RTD Input 6 Target
[H6] RTD Input 6 Events
[H7] RTD Input 7 Function
[H7] RTD Input 7 ID
[H7] RTD Input 7 Type
[H7] RTD Input 7 Application
[H7] RTD Input 7 Alarm Temperature
[H7] RTD Input 7 Alarm Pickup Delay
[H7] RTD Input 7 Trip Temperature
[H7] RTD Input 7 Trip Pickup Delay
[H7] RTD Input 7 Trip Reset Delay
[H7] RTD Input 7 Trip Voting
[H7] RTD Input 7 Open
[H7] RTD Input 7 Block
[H7] RTD Input 7 Target
[H7] RTD Input 7 Events
[H8] RTD Input 8 Function
[H8] RTD Input 8 ID
[H8] RTD Input 8 Type
[H8] RTD Input 8 Application
[H8] RTD Input 8 Alarm Temperature
[H8] RTD Input 8 Alarm Pickup Delay
[H8] RTD Input 8 Trip Temperature
[H8] RTD Input 8 Trip Pickup Delay
[H8] RTD Input 8 Trip Reset Delay
[H8] RTD Input 8 Trip Voting
[H8] RTD Input 8 Open
[H8] RTD Input 8 Block
[H8] RTD Input 8 Target
[H8] RTD Input 8 Events

OFF
Latched
Enabled
Enabled
Bearing 1
100 Ohm Platinum
Bearing
90 C
2.00 s
110 C
2.00 s
5.00 s
None
Block
OFF
Latched
Enabled
Enabled
Bearing 2
100 Ohm Platinum
Bearing
90 C
2.00 s
110 C
2.00 s
5.00 s
None
Block
OFF
Latched
Enabled
Enabled
Gear Oil
100 Ohm Platinum
Group 1
85 C
5.00 s
95 C
2.00 s
5.00 s
None
Block
OFF
Latched
Enabled
Enabled
Gear Bearing
100 Ohm Platinum
Group 2
105 C
5.00 s
115 C
2.00 s
5.00 s
None
Block
OFF
Latched
Enabled

Das könnte Ihnen auch gefallen