Beruflich Dokumente
Kultur Dokumente
Product Datasheet
Introduction
Special Feature
ALLTEC Corporation was founded in 1991.
Ourmission is to provide viable and thorough
solutions to lightning-related problems. We began
with the design and installation of structural
lightning protection and grounding systems. Since
then, ALLTEC has extended its manufacturing
capabilities with the introduction of TerraDyne
Electrolytic Grounding Systems,
TerraStat
Lightning Dissipation Systems, and the ATP series
Transient Voltage Surge Suppressors.
Circuit Redundancy
n
Redundancy protection circuit to prevent
the repetitive surges
Copyright 2003,
ACP Series:
Economic TVSS
SP20, 8/20 s, 20kA, 1F , 220VAC
SP40, 8/20 s, 40kA, 1F , 220VAC
TP40, 8/20 s, 40kA, 1F , 220VAC
( have option 35mm Din Rail connection )
ADP Series:
It is terminal strip protector will ensure
The reliable operation of networked equipment
connected to Token Ring, RS232, RS422, Short Haul
Modems, Muxes, DDS, Analog Dial Up, ISDN, T1 and
most other communication interfaces.
ASP Series:
It will guard sensitive data networks against
lightning induced surges, AC Power Interface,
electrostatic discharge, and ground loop energies.
Typical application included: data communications
and instrumentation interface using Token Ring,
RS423, RS232, Short Haul Modem, Muxes, DDS,
CSU/DSU, ISDN, T1 and most communication
interface.
AAK Series:
16 or 32 ports, 19 in. rack mounted protector
as well as 16 and 32 ports standoff units for wall
mounted protection. Wide varity of communication
interface are supported that inlcuded: 10BASE-T &
100BASE-T Ethernet, ATM155, CDD1, 100VG-AnyLan,
RS422, RS232, Token Ring, Lease Line, ISDN, T1,
DDS, Dial-UP Modem and high speed LAN/WAN
application.
AIP Series:
9, 15 , 24 , 36 pin subminiature D and centronics
connector interface protector ensure the reliable
operation of parallel and serial devices such as
printers, external modems, point od sales terminals.
Copyright 2003,
Model: NPE
Model: AP60
According to TVSS classification definition,
For protecting low-voltage installation against
surges, also in case of direct lightning strikes. Tested
with lightning impulse current (10/350 s).
Each AP protector can protect L/N only..
AP60 can install to 35mm standard Din rail.
Nominal voltage:
Max.Continuous
operating voltage:
Class:
Test level:
Insulation Resistance::
Voltage protection level:
Response time:
Nominal voltage:
Max.Continuous
operating voltage:
Testing Impulse
( 10/ 350 s )
Max Impulse current
250 VAC / 50 60 Hz
300 VAC
B
Class I
> 1GO
< 2.5Kv
< 100ns
Height
Wide
Deep
61mm
36mm
100mm
250 VAC
Class:
C
Voltage protection level: 750VAC
Response time:
< 5ns
Testing Impulse
( 8/250 s )
Max Impulse current
120kA
250 VAC / 50 60 Hz
40kA
Copyright 2003,
Height
Wide
Deep
61mm
36mm
100mm
Power System:
1 Phase
Connection:
Parallel
Protection Technology: Integrated,
Multi-surge Protection
Max. Discharge Current 10 30 kA, ( 8/20us )
Leakage Current:
9 A
Response Time:
< 5 ns
Electromagnetic:
Compliant to CE-EMC
Capability
Protection:
Over Current Protection
Over Temp. Protection
Status Indication:
Green LED normal
Operating Temperature: -40 to + 85
Relative Humidity:
< 95%
Installation:
35mm standard Din Rail
Connection Cable Size: 6 mm
Dimension:
Height
61mm
Weight
36mm
Deep
100mm
Power System:
1 Phase
Connection:
Serial
Protection Technology: Integrated,
Multi-surge Protection
Max. Discharge Current 10 30 kA, ( 8/20us )
Leakage Current:
9 A
Response Time:
< 5 ns
Electromagnetic:
Compliant to CE-EMC
Capability
Protection:
Over Current Protection
Over Temp. Protection
Status Indication:
Green LED normal
Operating Temperature: -40 to + 85
Relative Humidity:
< 95%
Installation:
35mm standard Din Rail
Connection Cable Size: 6 mm
Dimension:
Height
61mm
Weight
36mm
Deep
100mm
Operating
Voltage
Max. Input
Voltage
Max. Res.
V @ Max.
Surge
Input
Max.
surge
Current
( 8/20us )
18VA
C
20VA
C
24VAC
48VAC
125VAC
240VAC
30VAC
90VAC
230VAC
385VAC
77VA
C
110VA
C
200VAC
360VAC
800VAC
10kA
10kA
30kA
30kA
30kA
Operating
Voltage
Max. Input
Voltage
Max. Res
V. @ Max.
Surge
Current
Max.
Surge
Current
( 8/20us )
Copyright 2003,
24VDC
32VDC
48VDC
125VDC
240VDC
26VDC
38VDC
56VDC
230VDC
385VDC
77VDC
110VDC
135VDC
300VDC
800VDC
10kA
10kA
30kA
30kA
30kA
Model: ATP120
Power System:
3 Phase
Connection:
Parallel
Protection Technology: Integrated,
Multi-surge Protection
Protection Mode:
L-N, L-L, N-G Full Protect
Operating Voltage:
220 / 380VAC / 50 60 Hz
Max Operating Voltage: 480 VAC
Max Discharge current: 160 kA
( 8/20us )
Protection Level:
780 VAC
Leakage Current:
9 A
Response Time:
< 5 ns
Electromagnetic:
Compliant to CE-EMC
Capability
Protection:
Over Current Protection
Over Temp. Protection
Status Indication:
LED for each phase
Green LED normal
Red LED - Fault
Operating Temperature: -40 to + 85
Relative Humidity:
< 95%
Installation:
wall mount
Connection Cable Size: 16 mm
Dimension:
Height
70 mm
Weight
184 mm
Deep
290 mm
Power System:
3 Phase
Connection:
Parallel
Protection Technology: Integrated,
Multi-surge Protection
Protection Mode:
L-N, L-L, N-G Full Protect
Operating Voltage:
220 / 380VAC / 50 60 Hz
Max Operating Voltage: 480 VAC
Max Discharge current: 120 kA
( 8/20us )
Protection Level:
780 VAC
Leakage Current:
9 A
Response Time:
< 5 ns
Electromagnetic:
Compliant to CE-EMC
Capability
Protection:
Over Current Protection
Over Temp. Protection
Status Indication:
LED for each phase
Green LED normal
Red LED - Fault
Operating Temperature: -40 to + 85
Relative Humidity:
< 95%
Installation:
wall mount
Connection Cable Size: 16 mm
Dimension:
Height
70 mm
Weight
184 mm
Deep
290 mm
Copyright 2003,
Power System:
3 Phase
Connection:
Parallel
Protection Technology: Integrated,
Multi-surge Protection
Protection Mode:
L-N, L-L, N-G Full Protect
Operating Voltage:
220 / 380VAC / 50 60 Hz
Max Operating Voltage: 480 VAC
Max Discharge current: 90 kA
( 8/20us )
Protection Level:
750 VAC
Leakage Current:
9 A
Response Time:
< 5 ns
Electromagnetic:
Compliant to CE-EMC
Capability
Protection:
Over Current Protection
Over Temp. Protection
Status Indication:
LED for each phase
Green LED normal
Red LED - Fault
Operating Temperature: -40 to + 85
Relative Humidity:
< 95%
Installation:
wall mount
Connection Cable Size: 16 mm
Dimension:
Height
70 mm
Weight
161 mm
Deep
257 mm
Model: ATP50
Power System:
3 Phase
Connection:
Parallel
Protection Technology: Integrated,
Multi-surge Protection
Protection Mode:
L-N, L-L, N-G Full Protect
Operating Voltage:
220 / 380VAC / 50 60 Hz
Max Operating Voltage: 480 VAC
Max Discharge current: 50 kA
( 8/20us )
Protection Level:
750 VAC
Leakage Current:
9 A
Response Time:
< 5 ns
Electromagnetic:
Compliant to CE-EMC
Capability
Protection:
Over Current Protection
Over Temp. Protection
Status Indication:
LED for each phase
Green LED normal
Red LED - Fault
Operating Temperature: -40 to + 85
Relative Humidity:
< 95%
Installation:
wall mount
Connection Cable Size: 16 mm
Dimension:
Height
70 mm
Weight
161 mm
Deep
257 mm
Copyright 2003,
Model: ATP30/s
Power System:
3 Phase
Connection:
Parallel
Protection Technology: Integrated,
Multi-surge Protection
Protection Mode:
L-N, L-L, N-G Full Protect
Operating Voltage:
220 / 380VAC / 50 60 Hz
Max Operating Voltage: 480 VAC
Max Discharge current: 30 kA
( 8/20us )
Protection Level:
750 VAC
Leakage Current:
9 A
Response Time:
< 5 ns
Electromagnetic:
Compliant to CE-EMC
Capability
Protection:
Over Current Protection
Over Temp. Protection
Status Indication:
LED for each phase
Green LED normal
Red LED - Fault
Operating Temperature: -40 to + 85
Relative Humidity:
< 95%
Installation:
wall mount
Connection Cable Size: 16 mm
Dimension:
Height
70 mm
Weight
161 mm
Deep
257 mm
Power System:
1 Phase
Connection:
Parallel
Protection Technology: Integrated,
Multi-surge Protection
Protection Mode:
L-N, L-G, N-G Full Protect
Operating Voltage:
220VAC / 50 60 Hz
Max Operating Voltage: 480 VAC
Max Discharge current: 30 kA
( 8/20us )
Protection Level:
650 VAC
Leakage Current:
9 A
Response Time:
< 5 ns
Electromagnetic:
Compliant to CE-EMC
Capability
Protection:
Over Current Protection
Over Temp. Protection
Status Indication:
LED for each phase
Green LED normal
Red LED - Fault
Operating Temperature: -40 to + 85
Relative Humidity:
< 95%
Installation:
wall mount
Connection Cable Size: 16 mm
Dimension:
Height
51 mm
Weight
118 mm
Deep
200 mm
Copyright 2003,
Model: ATP20/s
Model: SP20
Power System:
1 Phase
Connection:
Parallel
Protection Technology: Integrated,
Multi-surge Protection
Protection Mode:
L-N, L-G, N-G Full Protect
Operating Voltage:
220VAC / 50 60 Hz
Max Operating Voltage: 480 VAC
Max Discharge current: 20 kA
( 8/20us )
Protection Level:
650 VAC
Leakage Current:
9 A
Response Time:
< 5 ns
Electromagnetic:
Compliant to CE-EMC
Capability
Protection:
Over Current Protection
Over Temp. Protection
Status Indication:
LED for each phase
Green LED normal
Red LED - Fault
Operating Temperature: -40 to + 85
Relative Humidity:
< 95%
Installation:
wall mount
Connection Cable Size: 16 mm
Dimension:
Height
51 mm
Weight
118 mm
Deep
200 mm
Power System:
1 Phase
Connection:
Parallel
Protection Technology: Integrated,
Multi-surge Protection
Protection Mode:
L-N, L-G, N-G
Protect
Operating Voltage:
220VAC / 50 60 Hz
Max Operating Voltage: 480 VAC
Max Discharge current: 20 kA
( 8/20us )
Protection Level:
650 VAC
Leakage Current:
9 A
Response Time:
< 5 ns
Electromagnetic:
Compliant to CE-EMC
Capability
Protection:
Over Current Protection
Over Temp. Protection
Status Indication:
LED for each phase
Green LED normal
Red LED - Fault
Operating Temperature: -40 to + 85
Relative Humidity:
< 95%
Installation:
wall mount
Connection Cable Size: 6 mm
Dimension:
Height
39 mm
Weight
69 mm
Deep
137 mm
Copyright 2003,
Full
Model: TP40
Power System:
1 Phase
Connection:
Parallel
Protection Technology: Integrated,
Multi-surge Protection
Protection Mode:
L-N, L-G, N-G Full Protect
Operating Voltage:
220VAC / 50 60 Hz
Max Operating Voltage: 480 VAC
Max Discharge current: 40 kA
( 8/20us )
Protection Level:
650 VAC
Leakage Current:
9 A
Response Time:
< 5 ns
Electromagnetic:
Compliant to CE-EMC
Capability
Protection:
Over Current Protection
Over Temp. Protection
Status Indication:
LED for each phase
Green LED normal
Red LED - Fault
Operating Temperature: -40 to + 85
Relative Humidity:
< 95%
Installation:
wall mount
Connection Cable Size: 6 mm
Dimension:
Height
39 mm
Weight
69 mm
Deep
137 mm
Power System:
3 Phase
Connection:
Parallel
Protection Technology: Integrated,
Multi-surge Protection
Protection Mode:
L-N, L-L, N-G
Protect
Operating Voltage:
220 / 380VAC / 50 60 Hz
Max Operating Voltage: 480 VAC
Max Discharge current: 40 kA
( 8/20us )
Protection Level:
650 VAC
Leakage Current:
9 A
Response Time:
< 5 ns
Electromagnetic:
Compliant to CE-EMC
Capability
Protection:
Over Current Protection
Over Temp. Protection
Status Indication:
LED for each phase
Green LED normal
Red LED - Fault
Operating Temperature: -40 to + 85
Relative Humidity:
< 95%
Installation:
wall mount
Connection Cable Size: 6 mm
Dimension:
Height
39 mm
Weight
121 mm
Deep
210 mm
Copyright 2003,
Full
Data TVSS
System Used
RS422, RS423
Ethernet,
DDS, T1, ISDN
100BaseT
RS232, Token Ring
4-20mA current loop
Arcnet,
4-20mA current loop
Leased Line
Dial up line, Modem,
Clamp V
Cod
e
7.5V
7.0V
12V
S
S
18V
27V
60V
240V
B
G
Application Range
It will ensure the reliable operation of local and
wide area networks. It offer protection for: 10BASET? 100BASE-T ? CDDI ? 100VG-AnyLan and ATM155.
For WAN and Telco applications it offer protection
for environments including: ISDN ? T1 ? FT1 ?
DDS ? Dial Up Modem? Fax and more.
Application Range
ACP series data line protector will ensure the
reliable operation of coaxial or twinaxial based
networking equipment running IBM3270, AS400,
Ethernet, ArcNet, Satellite / cable / closed circuit TV
and most other wideband communication interfaces.
ATJ-02G/RJ11
ATJ-04E/RJ11
ATJ-04T/RJ11
ATJ-04A/RJ11
ATJ-04B/RJ11
ATJ-04G/RJ11
ATJ-04E/RJ45
ATJ-04E/RJ45 C
ATJ-04T/RJ45
ATJ-C5
ATJ-Digital
CAT 6-PPC
ATJ-06E/RJ11
ATJ-06T/RJ11
ATJ-06A/RJ11
ATJ-06B/RJ11
ATJ-08E/RJ45
ACP-2DA-AN
ATJ-08T/RJ45
ACP-2DT-AN
50 BNC ARCNET
ATJ-08A/RJ45
ACP-2BM F/F
ATJ-08B/RJ45
ACP-2BM T
ATJ-08G/RJ45
ACP-2BM M/F
ATJ-DSL
RJ11? ? , ? ? 8 ?
ACP-CCTV
ATJ-DDS
ATJ-ISDN
ACP-2DA-EN
ACP-2DT-EN
ACP-2DA-N (EN) F/F
ACP-2DA-N (EN) M/F
ACP-CMS F/F
ACP-CMS M/F
Copyright 2003,
Application Range:
ASP devices will guard sensitive data networks
against lightning induced surges, it protect data
communications and instrumentation interfaces
using : Token Ring ? RS423 ? RS232 ? Short Haul
Modem? Muxes ? DDS ? PLC? ISDN ? T1 and other
communication interfaces.
Application Range:
AAK device includes 16 port, 19 in. rack mounted
protectors as well as 16 and 32 port, 5 in. standoff
units for wall mount protector. It upport the:
10BASE-T & 100BASE-T Ethernet ? ATM155 ?
CDD1 ? 100VG-AnyLan ? RS422 ? RS232 ? Token
Ring ? Lease Line ? ISDN ? T1 ? DDS ? Dial-UP and
high speed LAN/WAN application.
ASP-2B-E
ASP-2B-T
ASP-2B-A
ASP-2B-B
RAK16-E
ASP-2B-G
RAK16-T
ASP-4B-E
RAK16-A
ASP-4B-T
RAK16-B
RAK16-G
ASP-4B-A
ASP-4B-B
RAK16-E-C5
ASP-4B-G
RAK16-E/SO
ASP-6B-E
RAK16-T/SO
ASP-6B-T
RAK16-A/SO
ASP-6B-A
RAK16-B/SO
RAK16-G/SO
ASP-6B-B
ASP-6B-G
RAK16-E-C5/SO
ASP-8B-E
RAK32-E/SO
ASP-8B-T
RAK32-T/SO
ASP-8B-A
RAK32-A/SO
ASP-8B-B
RAK32-B/SO
ASP-8B-G
RAK32-G/SO
ASP-10B-E
RAK32-E-C5/SO
ASP-10B-T
ASP-10B-A
ASP-10B-B
ASP-10B-G
ASP-32B-E
ASP-32B-T
ASP-32B-A
ASP-32B-B
ASP-32B-G
ADP Series:
AIP Series:
Application Range:
ADP series of data communication line protectors
will ensures the reliable operation of hubs, bridges,
routers, switches and other networked equipment
running 10BASE-T ? Token Ring ? RS422 ? RS432 ?
RS232 ? Arcnet ? Token Ring? CSU/DSU ? DDS ?
ISDN, T1 and most other communication
environments.
ADP-H4 E
ADP-H4 T
ADP-H4 A
ADP-H4 B
ADP-H4 G
ADP-H4 E-C5
ADP-H8 E
ADP-H8 T
ADP-H8 A
ADP-H8 B
ADP-H8 G
ADP-H8 E-C5
ADP-H12 E
ADP-H12 T
ADP-H12 A
ADP-H12 B
ADP-H12 G
ADP-H12 E-C5
ADP-25 E
ADP-25 T
ADP-25 A
ADP-25 B
ADP-25 G
ADP-25 E-C5
ADP-50 E
ADP-50 T
ADP-50 A
ADP-50 B
ADP-50 G
ADP-50 E-C5
DB9 RS422
DB9 RS232
DB9 18VLC
DB-15 RS422
DB-15 RS232
DB15 EN
DB-25 RS422
DB-25 RS232
425-RS232
825-RS232
DB25-PARLL