1

WATER PROOFING DETAILS


ICC
Tuesday, September 15, 2015
AHC-AR-DD-T-0001
DISCRIPTION OF AREA/LOCATION
Non Tower Ground/Podium Top
connecting to Building

Revision No: R0
FINAL RECOMMENDATIONS
Single Component Pure Polyurethane Silcor 575 or equivalent
The First part consist of all surface area should cleaned up to visible of hair cracks /
aggregate texture. Cleaning of RCC member should be done by hacking tool,
wire brush, wire grinder & air blower etc. Open cracks & construction joints should
be sealed with cement mortar with additive. All clean & treated area should tested
for water tighness by flooding water. All wet spots & water leakage area should
mark for treatment.
The Second part consist of Supplying and Applying Silcor 575 or equivalent, A high
performance, low odour, one-part, fastcuring,high solids, polyurethane elastomer
waterproof membrane over uniform surface of deck slab. Apply to a minimum
total WFT (Wet Film Thickness) of 1.8mm to achieve the required minimum DFT of
1.5mm. Silcor 575 is a pure polyurethane elastomer. It does not contain bitumen or
tar and will not bleed or stain.Silcor 575 should have following minimum properties:
i) Solid % Vol: (91 3)
ii) Tensile Strength > 2.5 MPa (ASTM D412)
iii) Elongation > 500% (ASTM D412)
iv) Shore A Hardness - 75 5 (ASTM D2240)
v) Chemical Resistance - Excellent (ASTM C543)
shall be applied as per manufacture specification.

The Third part consist of Providing and laying avg. 100 mm thick, CM 1:4 screed
admixed with conplast WL or equivalent Integral Waterproofing Compound of
approved makes as per manufacturer's specifications
The Fourth part of Sand Broadcasting on Walls: Broadcast oven dried quartz sand
with very low organic content having grain size (0.5 1.2 mm) at 1- 1.5 Kg/sqm onto
the approved Primer only for increasing the adhesion face surface and improving
the mechanical adhesion of the membrane to the primer.Broadcasting sand is
always to full saturation to obtain an even surface within the tack time of the
primer.After full cure of the primer, the excess sand should be removed with a
scrubber and vacuum cleaner.
The Third part consist of Protection on Walls: Providing and applying one coat of
plaster CM 1:4 of 10-12mm thick and adding conplast WL or equivalent
waterproofing compound and curing the same thoroughly.

Car Park - Exposed for vehicle


traffic

Hybrid Organic Nano Lithium based floor coating Bluecrete / HB 500 / ACT Colour
or equivalent to be used on top of TRIMIX flooring
For Ramps - Anti skid coating to be used on top of TRIMIX flooring
Providing and laying Bluecrete / HB 500 / ACT Colour a high performance Hybrid
Organic Nano Lithium based floor coating with Superior floor protection against
abrasion, corrosion, chemicals & abuses, with a very low VOC and very low odour.
The coating shall be applied in three coats (apply 2 coats followed by fixing of
chairs & then apply a final coat) as per manufacturers specification to provide
strong, dust proof, non staining, better finish (semi gloss) surface top, which will be
resistant to acids, oils and reduce maintainence and cleaning cost. ( The
measurement shall be as per the actual surface area applied).

Sump / Floor Drains / Lift Pits

Internal side - Horizontal and or


vertical application

Highly Flexible 2 Part Cementitious Membrane Betec Flex S150 or equivalent


The First part consist of all surface area should cleaned up to visible of hair cracks /
aggregate texture. Cleaning of RCC member should be done by hacking tool,
wire brush, wire grinder & air blower etc. Open cracks & construction joints should
be sealed with cement mortar with additive. All clean & treated area should tested
for water tighness by flooding water. All wet spots & water leakage area should
mark for treatment.

Internal side - Horizontal and or


vertical application

The Second part consist of providing and applying Betec Flex S150 or equivalent
Brush applied Cementitious elastomeric acrylic water proof coating of approved
Grace applicator, in 2 coats to form minimum 1mm thick membrane. The
Waterproofing System is capable of forming a waterproof barrier around or inside
the concrete, complete. The Waterproofing System shall be able to withstand at
least 200 ft. of water head pressure, shall be pool-chemical resistant and shall form
a waterproof barrier around or inside the concrete, complete. Membrane should
have following minimum properties:
i) Tensile Strength >1.8N/mm2 (ASTM D412)
ii) Elongation >200% (ASTM D412)
iii) Adhesion to concrete >1.2N/mm2 (ASTM D4541)
iv) Water Vapour Transmission <15 g/m2/24 hrs (ASTM E96)
v) Crack Bridging - No Crack at 2mm (ASTM C836)
shall be applied as per manufacture specification.
The Third part consist of Protection on Floors: Providing and laying avg. 25 mm thick,
CM 1:4 screed admixed with conplast WL or equivalent Integral Waterproofing
Compound of approved makes as per manufacturer's specifications

The Third part consist of Protection on Walls: Providing and applying one coat of
plaster CM 1:4 of 10-12mm thick and adding conplast WL or equivalent
waterproofing compound and curing the same thoroughly.

4a

U G Tank

Highly Flexible 2 Part Cementitious Membrane Betec Flex S150 or equivalent


The First part consist of all surface area should cleaned up to visible of hair cracks /
aggregate texture. Cleaning of RCC member should be done by hacking tool,
wire brush, wire grinder & air blower etc. Open cracks & construction joints should
be sealed with cement mortar with additive. All clean & treated area should tested
for water tighness by flooding water. All wet spots & water leakage area should
mark for treatment.

Internal side - Horizontal and or


vertical application

The Second part consist of providing and applying Betec Flex S150 or equivalent
Brush applied Cementitious elastomeric acrylic water proof coating of approved
Grace applicator, in 2 coats to form minimum 1mm thick membrane. The
Waterproofing System is capable of forming a waterproof barrier around or inside
the concrete, complete. The Waterproofing System shall be able to withstand at
least 200 ft. of water head pressure, shall be pool-chemical resistant and shall form
a waterproof barrier around or inside the concrete, complete. Membrane should
have following minimum properties:
i) Tensile Strength >1.8N/mm2 (ASTM D412)
ii) Elongation >200% (ASTM D412)
iii) Adhesion to concrete >1.2N/mm2 (ASTM D4541)
iv) Water Vapour Transmission <15 g/m2/24 hrs (ASTM E96)
v) Crack Bridging - No Crack at 2mm (ASTM C836)
shall be applied as per manufacture specification.
The Third part consist of Protection on Floors: Providing and laying avg. 25 mm thick,
CM 1:4 screed admixed with conplast WL or equivalent Integral Waterproofing
Compound of approved makes as per manufacturer's specifications
The Third part consist of Protection on Walls: Providing and applying one coat of
plaster CM 1:4 of 10-12mm thick and adding conplast WL or equivalent
waterproofing compound and curing the same thoroughly.

4b

STP

Internal side - Horizontal and or


vertical application

Highly Flexible 2 Part Cementitious Membrane Betec Flex S150 or equivalent


The First part consist of all surface area should cleaned up to visible of hair cracks /
aggregate texture. Cleaning of RCC member should be done by hacking tool,
wire brush, wire grinder & air blower etc. Open cracks & construction joints should
be sealed with cement mortar with additive. All clean & treated area should tested
for water tighness by flooding water. All wet spots & water leakage area should
mark for treatment.

Internal side - Horizontal and or


vertical application

The Second part consist of providing and applying Betec Flex S150 or equivalent
Brush applied Cementitious elastomeric acrylic water proof coating of approved
Grace applicator, in 2 coats to form minimum 1mm thick membrane. The
Waterproofing System is capable of forming a waterproof barrier around or inside
the concrete, complete. The Waterproofing System shall be able to withstand at
least 200 ft. of water head pressure, shall be pool-chemical resistant and shall form
a waterproof barrier around or inside the concrete, complete. Membrane should
have following minimum properties:
i) Tensile Strength >1.8N/mm2 (ASTM D412)
ii) Elongation >200% (ASTM D412)
iii) Adhesion to concrete >1.2N/mm2 (ASTM D4541)
iv) Water Vapour Transmission <15 g/m2/24 hrs (ASTM E96)
v) Crack Bridging - No Crack at 2mm (ASTM C836)
shall be applied as per manufacture specification.
The Third part consist of Protection on Floors: Providing and laying avg. 25 mm thick,
CM 1:4 screed admixed with conplast WL or equivalent Integral Waterproofing
Compound of approved makes as per manufacturer's specifications
The Third part consist of Protection on Walls: Providing and applying one coat of
plaster CM 1:4 of 10-12mm thick and adding conplast WL or equivalent
waterproofing compound and curing the same thoroughly.
Epoxy Coating :- Providing and applying 2 coats of epoxy coating by mixing 2/3
components using slow speed heavy duty drilling machine fixed with mixing
paddle, applying first coat using brush or roller and allowing it to dry for 16-18 hrs,
applying second coat and allowing it to dry completely, etc and complete as per
manufacturer's specification.Membrane should have following minimum
properties:
Pot life:- 30 min. at 25 C
Mixed density :- approx. 1.50 g/ml at 27 C
Application temp :- 15 C to 35 C- Humidity should be below 70%
Dry film thickness : 130 microns in two coats;

Pump Room / Service floor /Fire


check floor / Plant Room

Single Component Pure Polyurethane Silcor 575 or equivalent


The First part consist of all surface area should cleaned up to visible of hair cracks /
aggregate texture. Cleaning of RCC member should be done by hacking tool,
wire brush, wire grinder & air blower etc. Open cracks & construction joints should
be sealed with cement mortar with additive. All clean & treated area should tested
for water tighness by flooding water. All wet spots & water leakage area should
mark for treatment.

Horizontal and or vertical


application

The Second part consist of Supplying and Applying Silcor 575 or equivalent, A high
performance, low odour, one-part, fastcuring,high solids, polyurethane elastomer
waterproof membrane over uniform surface of deck slab. Apply to a minimum
total WFT (Wet Film Thickness) of 1.8mm to achieve the required minimum DFT of
1.5mm. Silcor 575 is a pure polyurethane elastomer. It does not contain bitumen or
tar and will not bleed or stain.Silcor 575 should have following minimum properties:
i) Solid % Vol: (91 3)
ii) Tensile Strength > 2.5 MPa (ASTM D412)
iii) Elongation > 500% (ASTM D412)
iv) Shore A Hardness - 75 5 (ASTM D2240)
v) Chemical Resistance - Excellent (ASTM C543)
shall be applied as per manufacture specification.
The Third part consist of Protection on Floors: Providing and laying avg. 40mm thick,
CM 1:4 screed admixed with conplast WL or equivalent Integral Waterproofing
Compound of approved makes as per manufacturer's specifications
The Third part consist of Sand Broadcasting on Walls:- Broadcast oven dried quartz
sand with very low organic content having grain size (0.5 1.2 mm) at 1- 1.5
Kg/sqm onto the approved Primer only for increasing the adhesion face surface
and improving the mechanical adhesion of the membrane to the
primer.Broadcasting sand is always to full saturation to obtain an even surface
within the tack time of the primer.After full cure of the primer, the excess sand
should be removed with a scrubber and vacuum cleaner.
The Third part consist of Protection on Walls: Providing and applying one coat of
plaster CM 1:4 of 10-12mm thick and adding conplast WL or equivalent
waterproofing compound and curing the same thoroughly.

Exposed concrete/Faade
treatment( SPANDRELS)

Liquid Applied Moisture Protection Coating Perma Barrier or equivalent


Supplying and laying Perm-A-Barrier Wall Membrane is a tough, self-adhering, selfsealing waterproofing membrane for air and vapor barrier applications. Consisting
of .036 in (0.9mm) of rubberized asphalt integrally bonded to .004 in (0.1mm) high
density cross laminated polyethylene film. Perm-A-Barrier Wall Membrane, when
combined with a structural substrate, produces a virtually impermeable air, vapor
and water barrier on concrete, masonry, gypsum board and wood walls. It is
designed to be a cost-effective system providing a continuous seal against air,
vapor and moisture around the entire building. Membrane should have following
minimum properties:
Minimum elongation 200%
puncture resistance - 40lbs (178N)
Water absorption - 0.1%
shall be applied as per manufacture specification.

Balconies / Toilet / Kitchen / Dry


wall/ Duct Wall

Single Component PU Base Polyurethane Silcor 560 or equivalent


The First part consist of all surface area should cleaned up to visible of hair cracks /
aggregate texture. Cleaning of RCC member should be done by hacking tool,
wire brush, wire grinder & air blower etc. Open cracks & construction joints should
be sealed with cement mortar with additive. All clean & treated area should tested
for water tighness by flooding water. All wet spots & water leakage area should
mark for treatment.

Horizontal and or vertical


application

The Second part consist of Supplying and Applying Silcor 560 or equivalent A high
performance, low odour, one-part, fastcuring,high solids, polyurethane elastomer
waterproof membrane over uniform surface of deck slab. Apply to a minimum
total WFT (Wet Film Thickness) of 1.8mm to achieve the required minimum DFT of
1.5mm. Silcor 560 is a pure polyurethane elastomer. It does not contain bitumen or
tar and will not bleed or stain.Silcor 560 should have following minimum properties:
i) Solid % Vol: (91 3)
ii) Tensile Strength > 2.0 MPa (ASTM D412)
iii) Elongation > 550% (ASTM D412)
iv) Shore A Hardness - 60 5 (ASTM D2240)
v) Chemical Resistance - Excellent (ASTM C543)
shall be applied as per manufacture specification.
The Third part consist of Protection on Floors: Providing and laying avg. 25 mm thick,
CM 1:4 screed admixed with conplast WL or equivalent Integral Waterproofing
Compound of approved makes as per manufacturer's specifications
The Third part consist of Sand Broadcasting on Walls:- Broadcast oven dried quartz
sand with very low organic content having grain size (0.5 1.2 mm) at 1- 1.5
Kg/sqm onto the approved Primer only for increasing the adhesion face surface
and improving the mechanical adhesion of the membrane to the
primer.Broadcasting sand is always to full saturation to obtain an even surface
within the tack time of the primer.After full cure of the primer, the excess sand
should be removed with a scrubber and vacuum cleaner.
The Third part consist of Protection on Walls: Providing and applying one coat of
plaster CM 1:4 of 10-12mm thick and adding conplast WL or equivalent
waterproofing compound and curing the same thoroughly.

8a

Terrace Usable

Horizontal and or vertical


application

Single Component Pure Polyurethane Silcor 575 or equivalent


The First part consist of all surface area should cleaned up to visible of hair cracks /
aggregate texture. Cleaning of RCC member should be done by hacking tool,
wire brush, wire grinder & air blower etc. Open cracks & construction joints should
be sealed with cement mortar with additive. All clean & treated area should tested
for water tighness by flooding water. All wet spots & water leakage area should
mark for treatment.

Horizontal and or vertical


application

The Second part consist of Supplying and Applying Silcor 575 or equivalent, A high
performance, low odour, one-part, fastcuring,high solids, polyurethane elastomer
waterproof membrane over uniform surface of deck slab. Apply to a minimum
total WFT (Wet Film Thickness) of 1.8mm to achieve the required minimum DFT of
1.5mm. Silcor 575 is a pure polyurethane elastomer. It does not contain bitumen or
tar and will not bleed or stain.Silcor 575 should have following minimum properties:
i) Solid % Vol: (91 3)
ii) Tensile Strength > 2.5 MPa (ASTM D412)
iii) Elongation > 500% (ASTM D412)
iv) Shore A Hardness - 75 5 (ASTM D2240)
v) Chemical Resistance - Excellent (ASTM C543)
shall be applied as per manufacture specification.
The Third part consist of The slope making part consists of providing and laying of
100mm average thick screed concrete of M20 grade in slope as per manufacturers
specification.
The Fourth part of Sand Broadcasting on Walls: Broadcast oven dried quartz sand
with very low organic content having grain size (0.5 1.2 mm) at 1- 1.5 Kg/sqm onto
the approved Primer only for increasing the adhesion face surface and improving
the mechanical adhesion of the membrane to the primer.Broadcasting sand is
always to full saturation to obtain an even surface within the tack time of the
primer.After full cure of the primer, the excess sand should be removed with a
scrubber and vacuum cleaner.
The Third part consist of Protection on Walls: Providing and applying one coat of
plaster CM 1:4 of 10-12mm thick and adding conplast WL or equivalent
waterproofing compound and curing the same thoroughly.

8b

Terrace Top

Horizontal and or vertical


application

2 Part Component Polyurethane Coating Silcor 580 or equivalent


The First part consist of all surface area should cleaned up to visible of hair cracks /
aggregate texture. Cleaning of RCC member should be done by hacking tool,
wire brush, wire grinder & air blower etc. Open cracks & construction joints should
be sealed with cement mortar with additive. All clean & treated area should tested
for water tighness by flooding water. All wet spots & water leakage area should
mark for treatment.
The Second part consist of Supplying and Applying Silcor 580 or equivalent, A high
performance, low odour, two-part, fastcuring,high solids, polyurethane elastomer
waterproof membrane over uniform surface of deck slab. Apply to a minimum
total WFT (Wet Film Thickness) of 1.8mm to achieve the required minimum DFT of
1.5mm. Silcor 580 is a pure polyurethane elastomer. It does not contain bitumen or
tar and will not bleed or stain.Silcor 580 should have following minimum properties:
i) Solid % Vol: >97
ii) Tensile Strength > 8.8 MPa (ASTM D412)
iii) Elongation > 350% (ASTM D412)
iv) Shore A Hardness - 80 5 (ASTM D2240)
v) Chemical Resistance - Excellent (ASTM C543)
shall be applied as per manufacture specification.

The Third part consist of The slope making part consists of providing and laying of
150mm average thick screed concrete of M20 grade in slope as per manufacturers
specification.
The Fourth part of Sand Broadcasting on Walls: Broadcast oven dried quartz sand
with very low organic content having grain size (0.5 1.2 mm) at 1- 1.5 Kg/sqm onto
the approved Primer only for increasing the adhesion face surface and improving
the mechanical adhesion of the membrane to the primer.Broadcasting sand is
always to full saturation to obtain an even surface within the tack time of the
primer.After full cure of the primer, the excess sand should be removed with a
scrubber and vacuum cleaner.
The Third part consist of Protection on Walls: Providing and applying one coat of
plaster CM 1:4 of 10-12mm thick and adding conplast WL or equivalent
waterproofing compound and curing the same thoroughly.
9

Swimming pool

Highly Flexible 2 Part Cementitious Membrane Betec Flex S150 or equivalent


The First part consist of all surface area should cleaned up to visible of hair cracks /
aggregate texture. Cleaning of RCC member should be done by hacking tool,
wire brush, wire grinder & air blower etc. Open cracks & construction joints should
be sealed with cement mortar with additive. All clean & treated area should tested
for water tighness by flooding water. All wet spots & water leakage area should
mark for treatment.

Horizontal and or vertical


application

The Second part consist of providing and applying Betec Flex S150 or equivalent
Brush applied Cementitious elastomeric acrylic water proof coating of approved
Grace applicator, in 2 coats to form minimum 1mm thick membrane. The
Waterproofing System is capable of forming a waterproof barrier around or inside
the concrete, complete. The Waterproofing System shall be able to withstand at
least 200 ft. of water head pressure, shall be pool-chemical resistant and shall form
a waterproof barrier around or inside the concrete, complete. Membrane should
have following minimum properties:
i) Tensile Strength >1.8N/mm2 (ASTM D412)
ii) Elongation >200% (ASTM D412)
iii) Adhesion to concrete >1.2N/mm2 (ASTM D4541)
iv) Water Vapour Transmission <15 g/m2/24 hrs (ASTM E96)
v) Crack Bridging - No Crack at 2mm (ASTM C836)
shall be applied as per manufacture specification.
The Third part consist of Protection on Floors: Providing and laying avg. 25 mm thick,
CM 1:4 screed admixed with conplast WL or equivalent Integral Waterproofing
Compound of approved makes as per manufacturer's specifications
The Third part consist of Protection on Walls: Providing and applying one coat of
plaster CM 1:4 of 10-12mm thick and adding conplast WL or equivalent
waterproofing compound and curing the same thoroughly.

10

Service & Fire Check floors

Horizontal and or vertical


application

Single Component Pure Polyurethane Silcor 575 or equivalent


The First part consist of all surface area should cleaned up to visible of hair cracks /
aggregate texture. Cleaning of RCC member should be done by hacking tool,
wire brush, wire grinder & air blower etc. Open cracks & construction joints should
be sealed with cement mortar with additive. All clean & treated area should tested
for water tighness by flooding water. All wet spots & water leakage area should
mark for treatment.
The Second part consist of Supplying and Applying Silcor 575 or equivalent, A high
performance, low odour, one-part, fastcuring,high solids, polyurethane elastomer
waterproof membrane over uniform surface of deck slab. Apply to a minimum
total WFT (Wet Film Thickness) of 1.8mm to achieve the required minimum DFT of
1.5mm. Silcor 575 is a pure polyurethane elastomer. It does not contain bitumen or
tar and will not bleed or stain.Silcor 575 should have following minimum properties:
i) Solid % Vol: (91 3)
ii) Tensile Strength > 2.5 MPa (ASTM D412)
iii) Elongation > 500% (ASTM D412)
iv) Shore A Hardness - 75 5 (ASTM D2240)
v) Chemical Resistance - Excellent (ASTM C543)
shall be applied as per manufacture specification.

The Third part consist of Providing and laying avg. 40 mm thick, CM 1:4 screed
admixed with conplast WL or equivalent Integral Waterproofing Compound of
approved makes as per manufacturer's specifications
The Third part consist of Protection on Walls: Providing and applying one coat of
plaster CM 1:4 of 10-12mm thick and adding conplast WL or equivalent
waterproofing compound and curing the same thoroughly.
11

Planter bed /Treepit

Single Component Pure Polyurethane Silcor 575 or equivalent


For Treepit - Antiroot membrane to be used
The First part consist of all surface area should cleaned up to visible of hair cracks /
aggregate texture. Cleaning of RCC member should be done by hacking tool,
wire brush, wire grinder & air blower etc. Open cracks & construction joints should
be sealed with cement mortar with additive. All clean & treated area should tested
for water tighness by flooding water. All wet spots & water leakage area should
mark for treatment.

Horizontal and or vertical


application

Horizontal and or vertical


application

The Second part consist of Supplying and Applying Silcor 575 or equivalent, A high
performance, low odour, one-part, fastcuring,high solids, polyurethane elastomer
waterproof membrane over uniform surface of deck slab. Apply to a minimum
total WFT (Wet Film Thickness) of 1.8mm to achieve the required minimum DFT of
1.5mm. Silcor 575 is a pure polyurethane elastomer. It does not contain bitumen or
tar and will not bleed or stain.Silcor 575 should have following minimum properties:
i) Solid % Vol: (91 3)
ii) Tensile Strength > 2.5 MPa (ASTM D412)
iii) Elongation > 500% (ASTM D412)
iv) Shore A Hardness - 75 5 (ASTM D2240)
v) Chemical Resistance - Excellent (ASTM C543)
shall be applied as per manufacture specification.

The Third part consist of Providing and laying avg. 25 mm thick, CM 1:4 screed
admixed with conplast WL or equivalent Integral Waterproofing Compound of
approved makes as per manufacturer's specifications
The Fourth part of Sand Broadcasting on Walls: Broadcast oven dried quartz sand
with very low organic content having grain size (0.5 1.2 mm) at 1- 1.5 Kg/sqm onto
the approved Primer only for increasing the adhesion face surface and improving
the mechanical adhesion of the membrane to the primer.Broadcasting sand is
always to full saturation to obtain an even surface within the tack time of the
primer.After full cure of the primer, the excess sand should be removed with a
scrubber and vacuum cleaner.
The Third part consist of Protection on Walls: Providing and applying one coat of
plaster CM 1:4 of 10-12mm thick and adding conplast WL or equivalent
waterproofing compound and curing the same thoroughly.