Sie sind auf Seite 1von 1

1-4"

4"

1-4"

7"

4"

4"

0.6" L. R. GRADE 270 STRANDS

4"

7"

NOTES
8"

8"

8"

8"

ALL PRESTRESSING STRANDS SHALL BE 7-WIRE LOW-RELAXATION GRADE 270

(SQUARE INCHES)

SPECIFICATIONS.

(LBS. PER STRAND)

(LBS. PER STRAND)

0.217

7"

APPLY EPOXY PROTECTIVE COATING TO END OF GIRDER SURFACES.

43,950

58,600

( SEE FRAMING PLAN


0R APPROVED EQUAL, AND SHALL MEET THE TYPE B REQUIREMENTS OF

THE TRANSFER OF LOAD FROM THE ANCHORAGES TO THE GIRDER SHALL BE DONE
WHEN CONCRETE HAS REACHED A COMPRESSIVE STRENGTH OF NOT LESS THAN
____ PSI.

THE TOP SURFACE OF THE GIRDER SHALL BE RAKED TO A DEPTH OF " EXCEPT

TYPE

LENGTH

#4

8-6"

WEIGHT

#4

8-6"

S2

#6

8-6"

S3

#6

4-8"

28

S4

56

#4

2-9"

103

102

S5

#4

9-6"

13

S6

#6

4-6"

27

7-2"

PRESET ANCHORS MAY BE NECESSARY IN THE PRESTRESSED CONCRETE GIRDER.

1
-5"

2"

"

DEPENDING ON THE TYPE OF SYSTEM USED TO SUPPORT THE DECK SLAB FORMS,

S5

SIZE

S1

INTERIOR GDR.

ALL PRESTRESSED STRANDS SHALL BE CUT FLUSH WITH THE GIRDER ENDS.

S4

NUMBER

S1

EXTERIOR GDR.

SUBSECTION 7.3 OF THE ANSI/AASHTO/AWS D1.5 BRIDGE WELDING CODE.

1
-2"

(
EA.FACE-

7"

STAGGERED)

#4

7"

@ 9"CTS.

3
-9"

1
-7"

3"

BAR

ANCHOR STUDS SHALL CONFORM TO AASHTO M169 GRADES 1010 THROUGH 1020

FOR LOCATION )

S3
OR
S6

REINFORCING STEEL FOR ONE GIRDER

STANDARD SPECIFICATIONS.

{ 1" ~ FORMED HOLE

2"

"

EMBEDDED PLATE B-1 SHALL BE GALVANIZED IN ACCORDANCE WITH THE

4"
3
-9"

APPLIED
PRESTRESS

REQUIREMENTS WHICHSHALL BE IN ACCORDANCE WITH THE STANDARD

2"

2"

S7

6"

S2

ULTIMATE
STRENGTH

AREA

STRANDS AND SHALL CONFORM TO AASHTO M203 EXCEPT FOR SAMPLING

EXTERIOR GDR.

S7

#5

INTERIOR GDR.

S7

#5

7-2"

EXTERIOR GDR.

S8

#4

STR

7-0"

#4

STR

7"

IN THE AREA BETWEEN THE STIRRUP AND THE EDGE OF THE GIRDER.

INTERIOR GDR.

HOLD DOWN DEVICES SHALL BE WITHIN 6" OF THE LOCATION SHOWN AND THE

2"

3"

2"

WHEN DRAPED STRANDS ARE DETAILED, THE LONGITUDINAL LOCATION OF THE

BAR TYPES

CENTER OF GRAVITY OF THE GROUP OF DRAPED STRANDS SHALL BE LOCATED


WITHIN " OF THE THEORETICAL LOCATION SHOWN.

3"

ALL BAR DIMENSIONS ARE OUT-TO-OUT

3"
FOR PRESTRESSED CONCRETE MEMBERS, SEE SPECIAL PROVISIONS.

6"

"

"
"

10
1
0

S
6

S
3

" S3
8
"

S9

HOLES

3"

S1

4"

S2

5"

4" 4"

" BEVEL EDGE

1-3"

10

"

S7

EMBEDDED PLATE B-1 DETAILS


3" 3"
TWO EMBEDDED PLATES B-1 ARE REQUIRED FOR EACH GIRDER.

3" 3"

3-6"

3-6"

MIN.

MIN.

4"

S7

(SEE NOTES)

S7

SECTION F
1
-6" S5

1
-9

10

"

"

1-3"

1
1"

"}

FORMED

"

1" ~
4"

7"

2
-7"

ANCHOR STUDS

X 5"
2
-7"

5"

"

0.6" LOW RELAXATION STRAND LAYOUT

4"

"

END OF GIRDER

1-3"

8"

S6 7

AT OF GIRDER
"

AT END OF GIRDER

10

SECTION C-C
(S1 BARS NOT SHOWN)

"

S3

S6 7"

2
-4"

2"

2"

SECTION A-A

2"

2"

"

11"
1-10"

"

11"

11"
1-10"

10

11"

4-0"

S5

3-5"

S7

QUANTITIES FOR ONE GIRDER


REINFORCING

____ PSI

STEEL

CONCRETE

STRANDS

C.Y.

No.

LB.

INTERIOR GIRDER

1-10"

6"

3-6"

3-6"

6"

1-10"

PARTIAL ELEVATION

EXTERIOR GIRDER

1-10"

6"

3-6"

3-6"

6"

1-10"

SHOWING INTERMEDIATE DIAPHRAGM

0.6"

L. R.

EXTERIOR GIRDER
INTERIOR GIRDER

REINFORCING STEEL FOR GIRDER Nos. _____

GIRDERS REQUIRED

1
-10"

1
-4"

1
-4"

1
-10"

( FOR INTERIOR GDRS. WITH SKEW < 70 OR SKEW > 110 )

NUMBER

LENGTH

TOTAL LENGTH

1" ~
FORMED

S8

HOLES

"

S2
S6

S1

S4 (TYP.)

S5

6"

2"

7 SPA. @ 6" = 3-6"

3"

S5

3"

S4 (TYP.)

S1

GIRDER
6"

2"

7 SPA. @ 6" = 3-6"

8"

5 SPA. @ 4" = 1-8"

5 SPA. @ 4" = 1-8"

ELEVATION OF GIRDER

8"

COUNTY
3
-9"

COATING

EPOXY PROTECTIVE

S3
S2

PROJECT NO.

6"

3"

3"

3"

S3
S6

BEARING

6"

COATING

PLAN OF GIRDER

6"

4
EPOXY PROTECTIVE

3
-9"

A
3"

"

6"

S7

STATION:

S7

SHEET
3" 3"
3-6"

OF

STATE OF NORTH CAROLINA

3-6"

DEPARTMENT OF TRANSPORTATION
RALEIGH

STANDARD

AASHTO TYPE III

PARTIAL ELEVATION

PRESTRESSED CONCRETE GIRDER

SHOWING INTERMEDIATE DIAPHRAGM


REINFORCING STEEL FOR GIRDER Nos. _____

BEARING

( FOR ALL EXTERIOR GIRDERS AND


INTERIOR GIRDERS WITH 70 < SKEW < 110 )

( SEE PARTIAL ELEVATION FOR ADDITIONAL S BARS )


ASSEMBLED BY :

DATE :

CHECKED BY :

DATE :

DRAWN BY :

JMB 12/87

CHECKED BY : ARB 12/87

REV. 10/1/11

SHEET NO.

REVISIONS
REVISIONS
NO.

MAA/GM

REV.

1/15

MAA/TMG

REV.

2/15

MAA/TMG

DOCUMENT NOT CONSIDERED


FINAL UNLESS ALL
SIGNATURES COMPLETED

1
2

BY:

DATE:

NO.

BY:

DATE:

3
4

STD. NO. PCG2

TOTAL
SHEETS

Das könnte Ihnen auch gefallen