Sie sind auf Seite 1von 2

ELECTRIC BOILERS

ELECTRIC BOILERS

A COMPLETE RANGE OF HIGH QUALITY ELECTRICALLY POWERED BOILERS

E-TECH S 160

380

L-XXL

A COMPLETE RANGE OF HIGH QUALITY ELECTRICALLY POWERED BOILERS

E-TECH W 15

Compact floor standing combination electric boiler.

Vented or Unvented use with mains pressure SystemPaks


available.
Integral primary heating sealed system kit and circulating
pump.
Can be used as a stand alone water heater.
3.5 Bar Mains water SmartPak and DHW mixing valve supplied
as standard.
Flexible installation options for flow and return connections.
Boiler insulated with rigid polyurethane foam without CFC
projected 70 mm.

Tank-In-Tank Technology
Reference

Quiet operation.

No flue required.

No annual landlord safety

certificate.

No condense pipe.

No carbon monoxide threat.

Multiple connections for installation flexibility.

XB501600

E-Tech S 160 Mono Phase

XL

XB501601

E-Tech S 160 Tri Phase

XL

XB502400

E-Tech S 240 Tri Phase

XL

XB503800

E-Tech S 380 Tri Phase

XL

Quiet operation.

No flue required.

No annual landlord safety


certificate.

No condense pipe.

No carbon monoxide threat.

Reference

Name

A1002096

E-Tech W 15 mono

A1002090

E-Tech W 15 tri

A1002091

E-Tech W 22 tri

A1002093

E-Tech W 28 tri

A1002094

E-Tech W 36 tri

TECHNICAL CHARACTERISTICS AND DIMENSIONS


Output power max (80/60C)

kW

ETW 15 - 1 Phase

ETW 15 - 3 Phase

ETW 22

ETW 28

ETW 36

14.4

14.4

21.6

28.8

36.0

Output power min (80/60C)

kW

9.6

9.6

14.4

14.4

18.0

Connection - heating

3/4

3/4

3/4

3/4

3/4

ETS 240 Tri (HEP)

ETS 380 Tri (HEP)

kW

14.4

14.4

28.8

28.8

Max operating temperature

85

85

85

85

85

Capacity (primary)

68

68

86

131

Max service pressure heating (primary)

bar

Capacity (domestic hot water)

99

99

164

263

Voltage

1x230

3x400 (+N)

3x400 (+N)

3x400 (+N)

3x400 (+N)

Connection - heating

1F

1F

1F

1F

Weight (empty)

kg

45

45

45

45

45

Connection - DHW

3/4 M

3/4 M

3/4 M

1 1/2 M

Width

mm

442

442

442

442

442

Max operating temperature

85

85

85

85

Height

mm

763

763

763

763

763

Max service pressure heating (primary)

bar

Depth

mm

332

332

332

332

332

1x230 + N

3x400 + N

3x400 + N

3x400 + N

Weight (empty)

kg

115

115

155

230

Width

mm

590

590

590

720

Height

mm

1342

1342

1818

2140

Depth

mm

728

728

728

810

Energy efficiency class - Heating

Energy efficiency class - Hot Water

ETS 160 Mono (HEP)

ETS 160 Tri (HEP)

ETS 240 Tri (HEP)

ETS 380 Tri (HEP)

Energy efficiency class

Also available, the E-Tech W Combi with DHW Kit


The E-Tech W can also be fitted with a domestic hot water kit to allow the production
of instantaneous hot water without the requirement for an additional tank.

DOMESTIC HOT WATER PERFORMANCE2


Peak flow at 45C

L/10

250

250

459

739

Peak flow 1st hour at 45C

L/60

570

570

990

1270

L/h

354

354

708

708

Peak flow at 60C

L/10

168

168

298

472

Peak flow 1st hour at 60C

L/60

375

375

555

752

L/h

248

248

408

448

Continuous flow at 45C

Continuous flow at 60C


2

Compatible with Honeywell S Plan or Y Plan wiring systems.


Compatible with radiator or underfloor heating installations.
Integral high efficiency boiler charging pump.
Modulating element input according to heating demand.
Built in control circuit protected by internal 3 amp MCB.
Removable heating elements constructed from
incoloy 800 stainless steel.

ETS 160 Tri (HEP)

Voltage

DOMESTIC
PRODUCT
GUIDE

ETS 160 Mono (HEP)

Output power max (80/60C)

An economical alternative to LPG & Oil

Name

TECHNICAL CHARACTERISTICS AND DIMENSIONS

36

Always ensure a safety thermostat is fitted to the underfloor heating circuit. ACV UK Ltd advise the installation of a Domestic hot water mixing valve on the hot flow immediately after the appliance.
Performance data assumes: Primary flow temperature 85 C - Domestic cold water supply 10 C.

Hot water and central heating solution


Up to 9.5 Litres/ minute hot water output at 45 degrees
Space saving
Available for the full E-Tech W range

Reference

Name

10800085

DHW Kit for E-Tech W

257F1132

Wiring for DHW kit for E-Tech W

ACV does not accept any responsibility resulting from any error in the transcription or printing of this document.
ACV reserves the right to change the technical specifications and components of its products without prior notice
in order to make improvements to its products.

ACV (UK) LTD


St. Davids Drive - St. Davids Business Park - Dalgety Bay - Fife - KY11 9PF
01382 820 100 - uk.info@acv.com - www.acv.com

Always ensure a safety thermostat is fitted to the underfloor heating circuit.

HIGH QUALITY
HIGH PERFORMANCE
ENERGY EFFICIENT

DHW
CYLINDERS
TANK-IN-TANK TECHNOLOGY FROM ACV
SMART GREEN 130

WHEN IT COMES TO PERFORMANCE, ENERGY SAVINGS AND SPACE SAVING, THE BENEFITS OF THE TANK-IN-TANK SYSTEM OUT PERFORM A TRADITIONAL COIL INSTALLATION ON ALMOST EVERY OCCASION.
THE LARGE HEAT SURFACE AREA OF THE TANK IN TANK GIVES EXCEPTIONALLY FAST RECOVERY AND CAN PROVIDE A CONTINUOUS FLOW OF HOT WATER SHOULD IT BE REQUIRED.

Exceptional re-heat time - 9 minutes1

210

SMART E 130

Fast recovery Class 'A' Tank-in-Tank DHW cylinder.

XB321300

Smart Green 130

XB321600

Smart Green 160

XB322100

Smart Green 210

SL 210 G

300

3kW Immersion heater as standard - 6kW option available.


6 pin plug-and-play electrical connection, S Plan or Y Plan.
Low Heat Loss - 50mm Polyurethane insulation.
Thick polypropylene jacket. Hard wearing and shock resistant.
DHW temperature gauge.
Anti-Legionella: Storage temperature > 60C.

3kW Immersion heater as standard - 6kW option available.


6 pin plug-and-play electrical connection, S-plan or Y-plan.
Low heat loss - 50 mm rigid polyurethane insulation.
Thick polypropylene jacket. Hard wearing and shock resistant.
DHW temperature gauge.
Anti-Legionella: Storage temperature > 60C.
The addition of multiple ports on the Smart E Plus not only gives the installer flexible
installation options, but also provides a cylinder built with the future in mind.

All Smartline E Plus cylinders come complete with an unvented Mains SystemPak as standard, which
includes a Mains Unvented Kit, Domestic Hot Water Mixing Valve, 3kW Immersion heater and 2 Port
Valve2.

Name

SL 160 G

Unrivalled resistance to scale

Fast recovery Tank-in-tank cylinder with the addition of multiple ports allowing
flexible installation options. Ideal partner to condensing boilers and heat pumps.

Reference

SL 130 G

Low pressure drop

SMART E PLUS 210

All Smartline E cylinders come complete with an unvented Mains SystemPak as standard, which
includes a Mains Unvented Kit, Domestic Hot Water Mixing Valve, 3kW Immersion heater and 2 Port
Valve2.

All Smartline Green cylinders come complete with an unvented Mains SystemPak as standard,
which includes a Mains Unvented Kit, Domestic Hot Water Mixing Valve and 2 port Valve2.

Reference

Name

XB301300

Smart E 130

XB301600

Smart E 160

TECHNICAL CHARACTERISTICS AND DIMENSIONS

SLE 130

SLE 160

Reference

Name

XB302100

Smart E Plus 210

XB302400

Smart E Plus 240

XB303000

Smart E Plus 300

TECHNICAL CHARACTERISTICS AND DIMENSIONS

SLE+ 210

SLE+ 240

SLE+ 300

Capacity (total)

130

161

203

Capacity (total)

130

161

Capacity (total)

203

242

293

Capacity (primary)

31

35

39

Capacity (primary)

55

62

Capacity (primary)

77

78

93

Capacity (domestic)

99

126

164

Capacity (domestic)

75

99

Capacity (domestic)

126

164

200

Connection - primary

1F

1F

1F

Connection - primary

1F

1F

Connection - primary

1F

1F

1F

Connection - DHW

3/4 M

3/4 M

3/4 M

Connection - DHW

3/4 M

3/4 M

Connection - DHW

3/4 M

3/4 M

3/4 M

Connection - re-circulation / safety valve

3/4 M

3/4 M

3/4 M

Connection - re-circulation / safety valve

3/4 M

3/4 M

Connection - re-circulation / safety valve

3/4 M

3/4 M

3/4 M

Max operating temperature (DHW)

80

80

80

Max operating temperature (DHW)

80

80

Max operating temperature (DHW)

80

80

80

Max operating pressure (DHW)

bar

8.6

8.6

8.6

Max operating pressure (DHW)

bar

8.6

8.6

Max operating pressure (DHW)

bar

8.6

8.6

8.6

Max operating pressure heating (primary)

bar

Max operating pressure heating (primary)

bar

Max operating pressure heating (primary)

bar

Weight (empty)

kg

55

65

75

Weight (empty)

kg

45

54

Weight (empty)

kg

66

76

87

Overall height (with connections)

mm

1025

1225

1497

Overall height (with connections)

mm

1025

1225

Overall height (with connections)

mm

1495

1740

2050

Overall width

mm

565

565

565

Overall width

mm

565

565

Overall width

mm

565

565

565

SL 130 G

SL 160 G

SL 210 G

SLE 130

SLE 160

SLE+ 210

SLE+ 240

SLE+ 300

Energy efficiency storage class

DOMESTIC HOT WATER PERFORMANCE3

Energy efficiency storage class

DOMESTIC HOT WATER PERFORMANCE3

Energy efficiency storage class

DOMESTIC HOT WATER PERFORMANCE3

Peak flow at 45C

L/10

275

348

469

Peak flow at 45C

L/10

202

275

Peak flow at 45C

L/10

348

469

640

Peak flow 1st hour at 45C

L/60

911

1156

1560

Peak flow 1st hour at 45C

L/60

672

911

Peak flow 1st hour at 45C

L/60

1156

1560

1920

L/h

763

970

1309

Continuous flow at 45C

L/h

564

763

Continuous flow at 45C

L/h

970

1309

1710

Peak flow at 60C

L/10

161

209

272

Peak flow at 60C

L/10

117

161

Peak flow at 60C

L/10

209

272

370

Peak flow 1st hour at 60C

L/60

549

689

913

Peak flow 1st hour at 60C

L/60

384

549

Peak flow 1st hour at 60C

L/60

689

913

1100

Continuous flow at 60C

L/h

465

576

769

Continuous flow at 60C

L/h

320

465

Continuous flow at 60C

L/h

576

769

970

Pre-heat time (EN12897:2006)

min

10

10

Pre-heat time (EN12897:2006)

min

10

10

Pre-heat time (EN12897:2006)

min

Max absorbed heat (Heat source: boiler)

kW

24.7

32.2

39.2

Max absorbed heat (Heat source: boiler)

kW

23

31

Max absorbed heat (Heat source: boiler)

kW

39

53

68

Heating surface area

1.03

1.26

Heating surface area

1.54

1.94

2.29

Continuous flow at 45C

160

Large heat transfer area

Fast recovery floor standing Tank-in-Tank cylinder.

Class A according to EU 812/2013.


6 pin plug-and-play electrical connection, S Plan or Y Plan.
Thick polypropylene jacket. Hard wearing and shock resistant.
Anti-Legionella: Storage temperature > 60C.
Very low standing heat loss - the combination of a vacuum insulation panel (VIP) and the
polyurethane foam offers optimal energy performance.
Integral thermostat control included (replaceable by a probe for use with an electronically
controlled boiler).

TECHNICAL CHARACTERISTICS AND DIMENSIONS

25 Year warranty on DHW Cylinder

Conditions: www.acv.com

ACV UK Ltd advise the installation of a Domestic hot water mixing valve on the hot flow immediately after the appliance.
3
Performance data assumes: Primary flow temperature 85 C - Domestic cold water supply 10 C.
2

For full specification on all ACV products, please visit www.acv.com

Das könnte Ihnen auch gefallen