Beruflich Dokumente
Kultur Dokumente
KEY PLAN
CUT OFF
100
BOTTOM LEVEL
OF FOUNDATION
(SEE FOUNDATION
PILING DRAWING)
SEE
DETAIL 1
100
SEE
DETAIL 1
WORKING
PLATFORM LEVEL
(+11,300m PWD)
550
(min.)
(NOTE 2)
BOTTOM LEVEL
OF FOUNDATION
(SEE FOUNDATION
PILING DRAWING)
CUT OFF
1130
40 (MIN)
(NOTE 3)
500
(min.)
(NOTE 2)
BOTTOM LEVEL
OF FOUNDATION
(SEE FOUNDATION
PILING DRAWING)
WORKING
PLATFORM LEVEL
(+11,300m PWD)
1130
40 (MIN)
(NOTE 3)
1130
WORKING
PLATFORM LEVEL
(+11,300m PWD)
100
500
(min.)
(NOTE 2)
40 (MIN)
(NOTE 3)
CUT OFF
E=1.000 m.
N=10.000 m.
GENERAL NOTES
40 (MIN)
(NOTE 3)
1460
CUT OFF
WORKING
PLATFORM LEVEL
(+11,300m PWD)
550
(min.)
(NOTE 2)
300
(min.)
MATERIAL NOTES
BOTTOM LEVEL
OF FOUNDATION
(SEE FOUNDATION
PILING DRAWING)
75
ELEMENTS
LOCALIZATION
fc'
(MPa)
ENVIRONMENT
MAX
W/C
RATIO
UNDERGROUND
ELEMENTS
PILES
30 MPa
MODERATE
0,45
75 mm
FOUNDATIONS
30 MPa
MODERATE
0,45
50 mm
OUTDOOR
ELEMENTS
ALL
30 MPa
SEVERE
0,45
40 mm
INDOOR
ELEMENTS
ALL
30 MPa
MILD
0,50
LEAN
CONCRETE
20 MPa
0,50
SPIRAL
75
SPIRAL
SECTION A-A
SECTION B-B
SCALE 1:30
SCALE 1:30
DETAIL 1 (FOUNDATION
THICKNESS <1,30m)
SCALE 1:30
MINIMUM
CEMENT
CONTENT
MINIMUM
COVER
(NOTE 1)
(NOTE 1)
REINFORCEMENT LAP AND ANCHORAGE LENGHT SHALL BE ACCORDING TO ACI 318 AND BNBC 2006.
CONCRETE NOMINAL COVER WHEN CAST AGAINST TO EARTH TO BE 75mm. UNLESS NOTED OTHERWISE.
CONCRETE CONSISTENCE SHALL BE SLUMP CLASS S2 FOR PLACED CONCRETE AND S3 FOR PUMPED
CONCRETE ACCORDING TO ACI 301.
ALL SHARPED EDGES SHALL BE CHAMFERED 20mm BY PLACING WOODEN SHIMS FASTENED TO THE
FORMWORKS.
ANTI-TERMITE SOIL TREATMENT TO BE CARRIED OUT WHEN NECESSARY, ACCORDING TO BNBC 2006.
ALL REINFORCEMENT WILL BE CONNECTED TO THE SITE EARTHING NETWORK ACCORDING TO THE
100
75
75
COUNTERCLOCKWISE.
KUSHIARA RIVER WATER LEVELS:
- LOW RIVER WATER LEVEL (LWL) IS -9,50m (+1,80m PWD).
- MEAN RIVER WATER LEVEL (MWL) IS -5,30m (+6,00m PWD).
- HIGH RIVER WATER LEVEL (HWL) IS -1,60m (+9,70m PWD).
460
(min.)
1460
SCALE 1:30
DETAIL 1 (FOUNDATION
75
75
75
SPIRAL
75
SPIRAL
PROPER BEHAVIOUR.
FOR CONCRETING UNDER WATER, THE CONCRETE SHALL CONTAIN AT LEAST 10% MORE CEMENT
THAN THE REQUIRED FOR THE SAME MIX PLACED IN DRY.
BLINDING CONCRETE AND MASSFILL: fc'=20 MPa ACCORDING TO BNBC 2006.
REINFORCEMENT STEEL GRADE 60 ACCORDING TO ASTM A615.
WORKING
PLATFORM LEVEL
(+11,300m PWD)
BOTTOM LEVEL
OF FOUNDATION
(SEE FOUNDATION
PILING DRAWING)
12000
(NOTE 1)
12000
(NOTE 1)
PARTICULAR NOTES
1.
2.
3.
4.
5.
FILLING
STRATUM
CUT-OFF MINIMUM 0,50m. TO BE CARRIED OUT BY THE CIVIL SUBCONTRACTOR SHALL BE ADAPTED
DEPENDING ON THE BOTTOM LEVEL OF EACH FOUNDATION.
CUT-OFF MINIMUM 0,04m TO BE CARRIED OUT BY THE PILING SUBCONTRACTOR SHALL BE EXECUTED UP TO
THE WORKING PLATFORM LEVEL.
DEPENDING ON FINAL CUT-OFF, EXCESS OF TOP REINFORCING WILL BE CUT OR BENT, FULFILLING
ANCHORAGE STRAIGHT OR HOOK, SEE DETAIL 1.
CEMENT TYPE IN PILES SHALL BE TYPE II (MODERATE SULPHATE RESISTANCE) OR TYPE I WITH C 3A
CONTENT LOWER THAN 8% ACCORDING TO ASTM C150. ADITIONALLY CEMENT TYPE IP(MS), IS(MS), P(MS),
I(PM)(MS), I(SM)(MS) ACCORDING TO ASTM C595 CAN BE USED.
REFERENCE DRAWINGS
6
(NOTE 1)
3m
SCALE 1:30
0 0,5 1
UG1
STRATUM
7m
SCALE 1:75
MINIMUM 4800
UG2
STRATUM
0,5
FOR CONSTRUCTION
MVA
DRA
JMP
FOR INFORMATION
GHA
DRA
JMP
STRATUMS
SCALE 1:30
SCALE 1:75
SCALE 1:30
A