Beruflich Dokumente
Kultur Dokumente
Approvals
FM
and
FMC
ATEX
IECEx
Flow
Measurement
Turbine
blades
Local regulation may restrict the use of this product below the conditions quoted. Limiting conditions refer to standard connections only.
In the interests of development and improvement of the product, we reserve the right to change the specication.
TI-P198-04-US 6.15
Technical data
Wetted materials
316L, 302, and 17-4PH, and 18-8 stainless steel, tungsten carbide, sapphire, plus:
DuPont Teflon based thread sealant on models with pressure transducer
DuPont Teflon packing on standard temperature models with packing gland
Graphite based packing on high temperature models with packing gland
Application
Any gas, liquid or steam compatible with 316L stainless steel and other listed
wetted materials. Not recommended for multi-phase fluids
Process
Temperature
Ambient
S option - Standard
H option - High
-267C to +454C
-488F to +850F
-40C to +60C
-40F to +140F
Storage
-40C to +85C
-40F to +185F
7 bar a
100 psi a
14 bar a
20 bar a
300 psi a
40 bar a
600 psi a
35 bar a
500 psi a
70 bar a
1 000 psi a
100 bar a
1 500 psi a
175 bar a
2 500 psi a
Process
2" Male NPT
2" 150 lb ange
2" 300 lb ange
2" 600 lb ange
2" Male NPT
2" 150 lb ange
2" 300 lb ange
2" Male NPT
2" 150 lb ange
2" 300 lb ange
2" Male NPT
2" 150 lb ange
2" 300 lb ange
2" 600 lb ange
Rating code
ASME 600 lb
ASME 150 lb
ASME 300 lb
ASME 600 lb
Ordering
CNPT
C150
C300
C600
PNPT
P150
P300
PNPT and RR
P150 and RR
P300 and RR
PNPTR
P150R
P300R
P600R
Style connection
Compression tting
Packing gland
Flow
Measurement
-67F to +450F
Operating
Pressure transducer
ratings
Pressure ratings
Packing gland
and
Removable retractor
Packing gland
and
Permanent retractor
Power requirements
-55C to +238C
200 psi a
3.5 bar g
50 psi g
ASME 600 lb
ASME 150 lb
ASME 300 lb
ASME 600 lb
ASME 150 lb
ASME 300 lb
ASME 600 lb
Display
Pushbuttons can be operated with magnetic wand without removal of the enclosure covers
Display can be mounted in 90 intervals for better viewing
Output signals
Analogue
Alarm
Totalizer pulse
Volumetric or Loop powered mass
Multivariable option 1
Multivariable option 2
4 - 20 mA
Solid state relay, 40 Vdc
50 millisecond pulse, 40 Vdc
One analogue, one totalizer pulse, HART, scaled frequncy output
Up to three analogue signals, three alarms, one totalizer pulse,
HART, scaled frequncy output
Modus RTU or BACnet MS / TP compatible process monitoring
Performance specifications
Accuracy
Process variables
Mass owrate accuracy for gas and steam based on 50 - 100 of pressure range
Liquids
Repeatability
Volumetric owrate
1.2 of rate
1.5 of rate
0.1 of rate
Negligible
Mass owrate
1.5 of rate
2.0 of rate
0.2 of rate
0.2 of rate
Temperature
1.0C ( 2.0F)
1.0C ( 2.0F)
1.0C ( 2.0F)
0.5C ( 0.9F)
Pressure
0.3 of full-scale
0.3 of full-scale
0.05 of full-scale
0.1 of full-scale
Density
0.3 of reading
0.5 of reading
0.1 of reading
0.1 of reading
Response time
Spirax Sarco, Inc., 1150 Northpoint Blvd., Blythewood, SC 29016 Phone: (803) 714-2000 Fax: (803) 714-2222
TI-P198-04-US 6.15
Weight
127 mm
(5")
127 mm
(5")
76 mm
(3")
" NPT
conduit entry
Electronics enclosure
Pressure transducer housing
(not present on RIM20 V, VT)
kg
lbs
kg
lbs
kg
lbs
CNPT
5.7
13
6.2
14
6.7
15
C150
6.8
15
7.3
16
7.8
17
C300
7.8
17
8.3
18
8.8
19
C600
8.2
18
8.7
19
9.2
20
Orientation Lever
102 mm
(4")
A
Compression fitting
Flow
Measurement
Stem
B
RIM20 V and VT
Compact Length
Standard Length
Extended Length
mm
inches
mm
536
21.1
229
536
21.1
536
536
RIM20 VTP
mm
CNPT
inches
mm
inches
mm
inches
mm
inches
mm
inches
9.0
953
37.5
645
25.4
1 257
49.5
950
37.4
257
10.1
953
37.5
673
26.5
1 257
49.5
978
38.5
21.1
254
10.0
953
37.5
671
26.4
1 257
49.5
975
38.4
21.1
244
9.6
953
37.5
660
26.0
1 257
49.5
965
38.0
Compact Length
Standard Length
Extended Length
inches
mm
inches
mm
inches
mm
inches
mm
inches
mm
inches
612
24.1
229
9.0
1 029
40.5
645
25.4
1 334
52.5
950
37.4
612
24.1
257
10.1
1 029
40.5
673
26.5
1 334
52.5
978
38.5
612
24.1
254
10.0
1 029
40.5
671
26.4
1 334
52.5
975
38.4
612
24.1
244
9.6
1 029
40.5
660
26.0
1 334
52.5
965
38.0
Spirax Sarco, Inc., 1150 Northpoint Blvd., Blythewood, SC 29016 Phone: (803) 714-2000 Fax: (803) 714-2222
TI-P198-04-US 6.15
Please note that a removable retractor can be used with these models
127 mm
(5")
76 mm
(3")
" NPT
conduit entry
Weight
Electronics enclosure
kg
PNPT
Orientation Lever
P150
9.4
P300
11.3
E
lbs
7.1
16
kg
lbs
7.6
17
21
9.9
22
25
11 .8
26
Stem
Stem clamp
Flow
Measurement
Packing gland
PNPT
RIM20
V, VT and VTP
Standard Length
Extended Length
A
mm
B
inches
mm
A
inches
mm
B
inches
inches
1 016
40.0
526
20.7
1321
52.0
831
32.7
1 016
40.0
516
20.3
1321
52.0
820
32.3
1 016
40.0
516
20.3
1321
52.0
820
32.3
Spirax Sarco, Inc., 1150 Northpoint Blvd., Blythewood, SC 29016 Phone: (803) 714-2000 Fax: (803) 714-2222
mm
TI-P198-04-US 6.15
203 mm
(8")
127 mm
(5")
76 mm
(3")
" NPT
conduit entry
Weight
Electronics
enclosure
kg
Pressure transducer
housing (not present
on RIM20 V, VT)
PNPT
Orientation
lever
lbs
11.5
kg
25
lbs
14.5
32
P150
13.7
30
16.7
37
P300
15.5
34
18.5
41
P600
16.0
35
19.0
42
Retractor
Stem
Flow
Measurement
Packing gland
Retractor
handle
P150R
P300R
P600R
RIM20
V, VT and VTP
Standard Length
Extended Length
A
mm
PNPTR
B
inches
mm
A
inches
mm
B
inches
mm
inches
1 016
40.0
526
20.7
1321
52.0
831
32.7
1 016
40.0
516
20.3
1321
52.0
820
32.3
1 016
40.0
516
20.3
1321
52.0
820
32.3
Remote electronics
option
76 mm
(3")
127 mm
(5")
211 mm
(8.3")
53 mm
(2.1")
145 mm
(5.7")
Remote cable
15 metres (50 ft)
8 mm
(0.315")
'U' bolt
provided
127 mm
(5")
76 mm
(3")
76 mm
(3")
12.7 mm
(0.5")
Spirax Sarco, Inc., 1150 Northpoint Blvd., Blythewood, SC 29016 Phone: (803) 714-2000 Fax: (803) 714-2222
TI-P198-04-US 6.15
Pressure
1.4 bar g
R40
5 bar g
10 bar g
1.4 bar g
R30
5 bar g
10 bar g
1.4 bar g
R20
5 bar g
Flow
Measurement
150 mm
400 mm
600 mm
Minimum
17
72
127
297
491
1 219
Maximum
225
929
1 642
3 817
6 270
15 367
Minimum
42
173
306
713
1 176
2 907
36 400
Maximum
537
2 216
3 915
9 090
14 905
Minimum
75
310
549
1 279
2 106
5 194
Maximum
962
3 963
6 999
16 239
26 600
64 815
Minimum
20
82
146
341
563
1 396
Maximum
329
1 358
2 399
5 575
9 149
22 384
Minimum
48
198
350
817
1 347
3 328
52 993
Maximum
785
3 237
5 716
13 265
21 735
Minimum
86
355
629
1 465
2 411
5 943
Maximum
1 405
5 786
10 215
23 687
38 771
94 337
Minimum
35
146
259
604
995
2 463
Maximum
530
2 187
3 863
8 968
14 704
35 898
Minimum
85
350
620
1 444
2 377
5 856
Maximum
1 265
5 207
9 194
21 322
34 903
84 940
Minimum
152
628
1 111
2 586
4 252
10 448
Maximum
2 261
9 303
16 419
38 049
62 227
151 156
Minimum
1.4 bar g
Maximum
Minimum
5 bar g
Maximum
Minimum
10 bar g
Maximum
61
1 098
147
2 615
263
4 672
253
4 522
606
10 755
1 087
19 197
448
7 985
1 072
18 979
1 921
33 862
1 045
18 520
2 496
43 967
4 466
78 386
1 721
30 320
4 103
71 883
7 335
128 050
4 247
73 805
10 082
174 497
17 975
310 382
10 bar g
R10
80 mm
Pressure
1.4 bar g
R40
5 bar g
10 bar g
1.4 bar g
R30
5 bar g
10 bar g
1.4 bar g
R20
5 bar g
10 bar g
1.4 bar g
R10
5 bar g
10 bar g
Minimum
Maximum
Minimum
Maximum
Minimum
Maximum
Minimum
Maximum
Minimum
Maximum
Minimum
Maximum
Minimum
Maximum
Minimum
Maximum
Minimum
Maximum
Minimum
Maximum
Minimum
Maximum
Minimum
Maximum
80 mm
150 mm
400 mm
600 mm
12
154
74
946
137
1 751
14
226
84
1 382
157
2 556
24
365
150
2 224
278
4 110
42
756
259
4 595
480
8 481
49
639
305
3 898
567
7 205
56
934
350
5 690
649
10 511
100
1 505
618
9 149
1 146
16 888
174
3 115
1 069
18 874
1 980
34 799
87
1 130
540
6 884
1 002
12 718
100
1 651
619
10 046
1 148
18 548
178
2 660
1 094
16 145
2 026
29 789
308
5 502
1 890
33 290
3 499
61 349
337
4 320
2 072
26 152
3 835
48 216
386
6 306
2 373
38 115
4 390
70 237
684
10 139
4 182
61 166
7 731
112 643
1 184
20 919
7 214
125 842
13 323
231 535
838
10 607
5 107
63 694
9 423
117 169
960
15 455
5 844
92 698
10 779
170 473
1 696
24 794
10 271
148 520
18 929
273 032
2 927
50 995
17 668
304 938
32 541
560 318
204
2 628
1 259
15 969
2 332
29 476
234
3 839
1 441
23 290
2 671
42 965
415
6 179
2 544
37 407
4 709
68 956
718
12 768
4 393
77 048
8 125
141 871
Spirax Sarco, Inc., 1150 Northpoint Blvd., Blythewood, SC 29016 Phone: (803) 714-2000 Fax: (803) 714-2222
TI-P198-04-US 6.15
R40
100 psi g
200 psi g
5 psi g
R30
100 psi g
200 psi g
5 psi g
R20
100 psi g
3"
16"
24"
Minimum
22
91
162
378
625
1 555
Maximum
287
1 187
2 098
4 883
8 029
19 727
Minimum
119
496
878
2 046
3 371
8 328
104 092
Maximum
1 540
6 350
11 216
26 034
42 668
Minimum
220
913
1 615
3 761
6 191
15 249
Maximum
2 827
11 643
20 558
47 681
78 064
190 027
Minimum
25
105
186
434
717
1 782
Maximum
420
1 735
3 068
7 135
11 721
28 745
Minimum
137
568
1 006
2 344
3 861
9 530
151 526
Maximum
2 251
9 272
16 373
37 984
62 207
Minimum
253
1 046
1 850
4 308
7 088
17 446
Maximum
4 129
16 994
29 996
69 532
113 761
276 542
Minimum
45
186
330
770
1 270
3 150
Maximum
677
2 797
4 943
11 485
18 849
46 119
Minimum
243
1 005
1 778
4 140
6 811
16 762
242 834
Maximum
3 623
14 915
26 328
61 035
99 870
Minimum
447
1 848
3 268
7 601
12 492
30 657
Maximum
6 643
27 317
48 203
111 658
182 535
443 035
Minimum
Maximum
Minimum
100 psi g
Maximum
Minimum
200 psi g
Maximum
78
1 405
421
7 490
774
13 719
323
5 790
1 739
30 791
3 195
56 341
572
10 227
3 075
54 325
5 647
99 362
1 334
23 736
7 153
125 807
13 123
229 926
2 199
38 897
11 755
205 605
21 541
375 467
5 440
94 870
28 849
498 759
52 728
909 528
16"
24"
213
2 729
1 730
21 791
3 273
41 083
244
3 984
1 980
31 753
3 747
59 832
432
6 406
3 489
50 942
6 595
95 927
748
13 217
6 016
104 762
11 362
197 092
529
6 702
4 257
53 019
8 031
99 739
606
9 765
4 871
77 152
9 186
145 094
1 071
15 665
8 557
123 591
16 126
232 348
1 849
32 219
14 715
253 698
27 714
476 732
200 psi g
5 psi g
R10
6"
Flow
Measurement
Rotor
Pressure
5 psi g
R40
100 psi g
200 psi g
5 psi g
R30
100 psi g
200 psi g
5 psi g
R20
100 psi g
200 psi g
5 psi g
R10
100 psi g
200 psi g
Minimum
Maximum
Minimum
Maximum
Minimum
Maximum
Minimum
Maximum
Minimum
Maximum
Minimum
Maximum
Minimum
Maximum
Minimum
Maximum
Minimum
Maximum
Minimum
Maximum
Minimum
Maximum
Minimum
Maximum
3"
6"
7
98
62
790
117
1 494
9
143
71
1 153
134
2 181
15
230
125
1 855
237
3 506
26
478
216
3 831
410
7 230
31
404
255
3 252
484
6 146
36
590
292
4 746
555
8 964
63
951
517
7 628
979
14 397
110
1 968
893
15 728
1 691
29 650
129
1 660
1 051
13 313
1 992
25 128
148
2 426
1 204
19 412
2 281
36 617
262
3 904
2 124
31 168
4 020
58 747
454
8 067
3 666
64 166
6 933
120 804
Spirax Sarco, Inc., 1150 Northpoint Blvd., Blythewood, SC 29016 Phone: (803) 714-2000 Fax: (803) 714-2222
TI-P198-04-US 6.15
Water flowrates
m3 / hr
Size
Nominal
pipe size
Minimum
50 mm
2"
1.19
80 mm
3"
2.62
150 mm
6"
200 mm
GPM
Maximum
71.3
Minimum
Maximum
314
157
12
691
12.30
614
54
2 701
8"
24.80
1 062
109
4 678
300 mm 12"
56.00
2 402
247
10 575
400 mm 16"
87.60
3 753
386
16 524
600 mm 24"
199.00
8 538
877
37 590
Sizing considerations
Flow
Measurement
Piping conditions
Upstream
Downstream
10 D
5D
15 D
5D
30 D
5D
10 D
5D
20 D
5D
30 D
5D
D = Internal diameter of the pipe - If there is not a sufficient straight run of pipe, a flow rectifier
may be used to reduce the above diameter measurements.
Consult your local Spirax Sarco representative or the factory for your specific application.
Liquid
Velocity range
Gas or steam
Maximum 13 to 62 metres / second (43 to 205 feet / second) depending on rotor pitch
Minimum 1 to 3.7 metres / second (3.5 to 12 feet / second) depending on rotor pitch
Site selection
The flow measurement location should be selected to minimize turbulence and swirl. The extent of these flow disturbances depends
upon the piping configuration. Valves, elbows, pumps, and other piping components may add disturbances to the flow.
Hot-tap compatibility
With the removable or permanent retractor assembly the RIM20 is hot-tappable and can be installed and removed without shutting down
the process. An isolation valve with a pipe mounting kit is used to isolate the flowmeter from the process.
Spirax Sarco, Inc., 1150 Northpoint Blvd., Blythewood, SC 29016 Phone: (803) 714-2000 Fax: (803) 714-2222
TI-P198-04-US 6.15
Selection:
Category
Description
Flowmeter
Electronics
Probe
length
Electronics
enclosure
mounting
Display
Power supply
Output signal
Inclusive of the
scaled frequency
output
Process
temperature
Pressure
sensor
Process
connections
Rotor options
Grey =
Standard
Suffix code
- DL - 1H -
- P0 -
RIM20
V-
D
DL
1H
Flow
Measurement
How to order
P0
PNPTR-E
R40
PNPTR-E
- R40
How to order example: 1 off Spirax Sarco RIM20 - V - S - L - D - DL -1H - S - P0 - PNPTR-E - R40 rotor insertion owmeter.
Spirax Sarco, Inc., 1150 Northpoint Blvd., Blythewood, SC 29016 Phone: (803) 714-2000 Fax: (803) 714-2222
TI-P198-04-US 6.15