Beruflich Dokumente
Kultur Dokumente
James M. Lee
Department of Chemical Engineering
Washington State University
Pullman, WA 99164-2714
jmlee@wsu.edu
Introduction................................................................................... 1
9.2.
9.3.
9.4.
9.5.
9.6.
9.7.
Power Consumption.................................................................... 18
9.8.
9.9.
9ii
Chapter 9
Agitation and Aeration
9.1.
Introduction
9-2
directions: one part goes upward along the side, back to the center along the
liquid surface, and down to the impeller region along the agitating shaft; and
the other goes downward along the side and bottom, then back to the impeller
region. On the other hand, the axial flow impellers (propellers and pitched
blade paddles) generate flow downward to the tank bottom, then up the side
and back down the center to the impeller region. Therefore, the flat-blade disk
turbine has the advantage of limiting the short-circuiting of gas along the
drive shaft by forcing the gas, introduced from below, along the path into the
discharge jet.
Mass-Transfer Path: The path of gaseous substrate from a gas bubble to an
organelle in a microorganism can be divided into several steps (Figure 9.2) as
follows:
1. Transfer from bulk gas in a bubble to a relatively unmixed gas layer
2. Diffusion through the relatively unmixed gas layer
3. Diffusion through the relatively unmixed liquid layer surrounding the
bubble
4. Transfer from the relatively unmixed liquid layer to the bulk liquid
5. Transfer from the bulk liquid to the relatively unmixed liquid layer
surrounding a microorganism
6. Diffusion through the relatively unmixed liquid layer
7. Diffusion from the surface of a microorganism to an organelle in which
oxygen is consumed
Steps 3 and 5, the diffusion through the relatively unmixed liquid layers of
the bubble and the microorganism, are the slowest among those outlined
previously and, as a result, control the overall mass-transfer rate. Agitation
and aeration enhance the rate of mass transfer in these steps and increase the
interfacial area of both gas and liquid.
In this chapter, we study various correlations for gas-liquid mass transfer,
interfacial area, bubble size, gas hold-up, agitation power consumption, and
volumetric mass-transfer coefficient, which are vital tools for the design and
operation of fermenter systems. Criteria for the scale-up and shear sensitive
mixing are also presented. First of all, let's review basic mass-transfer
concepts important in understanding gas-liquid mass transfer in a
fermentation system.
9.2.
9-3
dC A
dz
(9.1)
which is Fick's first law written for the z-direction. The DAB in Eq. (9.1) is the
diffusivity of component A through B, which is a measure of its diffusive
mobility.
Molar flux relative to stationary coordinate NA is equal to
NA =
CA
dC A
( N A + N B ) DAB
C
dz
(9.2)
(9.3)
Diffusivity: The kinetic theory of liquids is much less advanced than that of
gases. Therefore, the correlation for diffusivities in liquids is not as reliable as
that for gases. Among several correlations reported, the Wilke-Chang
correlation (Wilke and Chang, 1955) is the most widely used for dilute
solutions of nonelectrolytes,
!
=
DAB
1.1731016 ( M B )0.5 T
VbA0.6
(9.4)
When the solvent is water, Skelland (1974) recommends the use of the
correlation developed by Othmer and Thakar (1953).
1.112 1013
D =
1.1VbA0.6
!
AB
(9.5)
9-4
MB
temperature, K
solution viscosity, kg/m s
VbA
association factor for the solvent: 2.26 for water, 1.9 for methanol,
1.5 for ethanol, 1.0 for unassociated solvents, such as benzene and
ethyl ether.
Example 9.1
Estimate the diffusivity for oxygen in water at 25C. Compare the predictions
from the Wilke-Chang and Othmer-Thakar correlations with the experimental
value of 2.5109 m2/s (Perry and Chilton, p. 3-225, 1973). Convert the
experimental value to that corresponding to a temperature of 40C.
Solution:
Oxygen is designated as component A, and water, component B. The
molecular volume of oxygen VbA is 0.0256 m3/kmol. The association factor
for water is 2.26. The viscosity of water at 25C is 8.904104 kg/m s
(CRC Handbook of Chemistry and Physics , p. F-38, 1983). In Eq. (9.4)
!
AB
D =
(8.904 10 ) (0.0256)
0.6
= 2.25109 m 2 / s
In Eq. (9.5)
!
AB
D =
1.112 1013
4 1.1
(8.904 10 ) (0.0256)
0.6
= 2.27 109 m 2 / s
9-5
!
!
( DAB
)predicted ( DAB
)experimental
100
% error =
!
( DAB
)experimental
The resulting errors are 9.6 percent and 9.2 percent for Eqs. (9.4) and (9.5),
respectively. Since the estimated possible error for the experimental value is
20 percent (Perry and Chilton, p. 3-225, 1973), the estimated values from
both equations are satisfactory.
!
T is constant for a given liquid
Eq. (9.4) suggests that the quantity DAB
system. Though this is an approximation, we may use it here to estimate the
diffusivity at 40C. Since the viscosity of water at 40C is 6.529104 kg/m s
from the handbook,
at 40! C = 2.5109
DAB
6.529 104 298
!
1.1 is constant,
If we use Eq. (9.5), DAB
1.1
!
AB
8.904 104
at 40 C = 2.5 10
=3.52 109 m 2 / s
6.529 10
9
qG
= kG (CG CGi )
A
(9.6)
where CG and CGi is the gas-side concentration at the bulk and the interface,
respectively, as shown in Figure 9.3. kG is the individual mass-transfer
coefficient for the gas phase and A is the interfacial area.
Similarly, the liquid-side phase mass flux NL is
NL =
qL
= k L (CL i CL )
A
(9.7)
9-6
Liquid
Gas
CG
CLi
CGi
kL /kG
CGi
CL
CL
CLi
Since the amount of solute transferred from the gas phase to the interface
must equal that from the interface to the liquid phase,
NG = N L
(9.8)
Substitution of Eq. (9.6) and Eq. (9.7) into Eq. (9.8) gives
CG CGi
CL CLi
kL
kG
(9.9)
which is equal to the slope of the curve connecting the (CL, CG) and (CLi, CGi),
as shown in Figure 9.3.
It is hard to determine the mass-transfer coefficient according to Eq. (9.6)
or Eq. (9.7) because we cannot measure the interfacial concentrations, CLi or
CGi. Therefore, it is convenient to define the overall mass-transfer coefficient
as follows:
N G = N L = K G (CG CG* ) = K L (CL* CL )
(9.10)
9-7
CG
CGi
CG*
CLi CL*
CL
Example 9.2
Derive the relationship between the overall mass-transfer coefficient for
liquid phase KL and the individual mass-transfer coefficients, kL and kG. How
can this relationship be simplified for sparingly soluble gases?
Solution:
According to Eqs. (9.7) and (9.10),
k L (CL i CL ) = K L (CL* CL )
(9.11)
(9.12)
1
1 (CL CL i )
= +
k L k L CL i CL
*
Since
k L (CL i CL ) = kG (CG CGi )
(9.13)
(9.14)
9-8
which is the relationship between KL, kL, and kG. M is the slope of the line
connecting (CLI, CGI) and ( CL* , CG) as shown in Figure 9.4.
For sparingly soluble gases, the slope of the equilibrium curve is very
steep; therefore, M is much greater than 1 and from Eq. (9.14)
K L kL
(9.15)
(9.16)
DAB
zf
(9.17)
D
k L = 2 AB
te
(9.18)
(t ) = sest
(9.19)
9-9
where s is the fractional rate of surface renewal. This theory predicts that
again the mass-transfer coefficient is proportional to the square root of the
molecular diffusivity
1/ 2
k L = ( sDAB )
(9.20)
9.3.
Example 9.3
The mass transfer coefficient kL of oxygen transfer in fermenters is a function
of Sauter mean diameter D32, diffusivity DAB, and density c viscosity c of
continuous phase (liquid phase). Sauter-mean diameter D32 can be calculated
from measured drop-size distribution from the following relationship,
n
n D
n D
D32 =
i=1
n
(9.21)
i=1
9-10
Solution:
The first step of Buckingham-Pi theorem is to count the total number of
parameters. In this case, there are five parameters: kL, D32, DAB, c, and c, all
of which can be expressed with three principle units: mass M, length L, and
time T. Therefore,
Number of parameter:
n=5
r=3
m = r =3
nm=53=2
(9.22)
b'
2 = D32a ' DAB
cc ' c
(9.23)
Now, the exponents of the above equations can be determined so that both
groups can be dimensionless by substituting each parameter with their
dimensions as
1 = La (L2 / T)b (M/L3 )c (L/T)
Collecting all exponents for M, T, and L unit,
M:
c=0
T:
b1=0
b = 1
L:
a + 2b 3c = 0
a=1
(9.24)
1 0
1
1 = D32
c kL =
DAB
9-11
(9.25)
c
DAB c
(9.26)
Earlier studies in mass transfer between the gas-liquid phase reported the
volumetric mass-transfer coefficient kLa. Since kLa is the combination of two
experimental parameters, mass-transfer coefficient and interfacial area, it is
difficult to identify which parameter is responsible for the change of kLa when
we change the operating condition of a fermenter. Calderbank and
Moo-Young (1961) separated kLa by measuring interfacial area and correlated
mass-transfer coefficients in gas-liquid dispersions in mixing vessels, and
sieve and sintered plate column, as follows:
1. For small bubbles less than 2.5 mm in diameter,
1/ 3
k L = 0.31N Sc
2 / 3
g
c
(9.27)
or
1/ 3
N Sh = 0.31N Sc N Gr
1/ 3
(9.28)
(9.29)
The more general forms which can be applied for both small rigid
sphere bubble and suspended solid particle are
1/ 3
2 DAB
2 / 3 c g
+ 0.31N Sc
kL =
c 2
D32
(9.30)
or
1/ 3
N Sh = 2.0 + 0.31N Sc N Gr
1/ 3
(9.31)
9-12
1/ 2 c g
k L = 0.42 N Sc
2
(9.32)
or
1/ 2
N Sh = 0.42 N Sc N Gr
1/ 3
(9.33)
Example 9.4
Estimate the mass-transfer coefficient for the oxygen dissolution in water
25C in a mixing vessel equipped with flat-blade disk turbine and sparger by
using Calderbank and Moo-Young's correlations.
Solution:
The diffusivity of the oxygen in water 25C is 2.5109 m2/s (Example
9.1). The viscosity and density of water at 25C is 8.904104 kg/m s (CRC
Handbook of Chemistry and Physics, p. F-38, 1983) and 997.08 kg/m3 (Perry
and Chilton, p. 3-71, 1973), respectively. The density of air can be calculated
from the ideal gas law,
PM 1.01325105 (29)
=
= 1.186kg/m3
air =
3
RT
8.314 10 (298)
Therefore the Schmidt number,
8.904 104
=
= 357.2
N Sc =
DAB 997.08(2.5109 )
Substituting in Eq. (9.27) for small bubbles,
k L = 0.31(357.2)
(997.08)2
9-13
1/ 3
k L = 0.42(357.2)
(997.08)2
1/ 3
= 4.58104 m/s
Therefore, for the air-water system, Eqs. (9.27) and (9.32) predict that the
mass-transfer coefficients for small and large bubbles are 1.27104 and
4.58104 m/s, respectively, which are independent of power consumption
and gas-flow rate.
Eq. (9.32) predicts that the the mass-transfer coefficient for the oxygen
dissolution in water 25C in a mixing vessel is 4.58104 m/s, regardless of
the power consumption and gas-flow rate as illustrated in the previous
example problem. Lopes De Figueiredo and Calderbank (1978) reported later
that the value of kL varies from 7.3104 to 3.4103 m/s, depending on the
power dissipation by impeller per unit volume (Pm/v) as
0.33
P
k L m
v
(9.34)
P
k L = 0.592 D m
v c
1/ 2
AB
(9.35)
9-14
k L D32
= 0.5 c
DAB
DAB
1/ 4
gD 3
32
2
c
3/8
gD 2
32 c
(9.36)
where c and are the kinematic viscosity of the continuous phase and
interfacial tension, respectively. Eq. (9.36) is applicable for column diameters
of up to 0.6 m, superficial gas velocities up to 25 m/s, and gas hold-ups to 30
percent.
9.4.
To calculate the gas absorption rate qL for Eq. (9.7), we need to know the
gas-liquid interfacial area, which can be measured employing several
techniques such as photography, light transmission, and laser optics.
The interfacial area per unit volume can be calculated from the
Sauter-mean diameter D32 and the volume fraction of gas-phase H, as follows:
a=
6H
D32
(9.37)
9-15
(9.38)
9.5.
g DC2 c
D32
= 26
DC
0.12
3
gDC
2
c
0.12
Vs
gDC
(9.39)
aDC
1 g DC2 L
=
0.1
gDC3
H 1.13
L2
(9.40)
9-16
( P v)0.4 0.2 Vs 1/ 2
c
= 1.44 m
0.6
Vt
(9.41)
for
0.3
0.7
Rei
NDI
< 20,000
Vs
DI2 N c
=
c
(9.42)
0.3
0.7
The interfacial area for N Re
( NDI / Vs ) > 20,000 can be calculated
i
from the interfacial area a0 obtained from Eq. (9.41) by using the
following relationship.
2.3a
0.7
log10
= (1.95105 ) N Rei
a0
0.3
NDI
Vs
(9.43)
2. For Vs > 0.02 m/s, Miller (1974) modified Eq. (9.41) by replacing the
aerated power input by mechanical agitation Pm with the effective
power input Pe, and the terminal velocity Vt with the sum of the
superficial gas velocity and the terminal velocity Vs + Vt. The effective
power input Pe combines both gas sparging and mechanical agitation
energy contributions. The modified equation is
a0
( P v)0.4 0.2 Vs 1/ 2
c
= 1.44 e
0.6
Vt + Vs
(9.44)
0.6
0.5 + 9.0104
= 4.15
0.4
0.2 H
( Pm v) c
(9.45)
0.4 0.25
0.6
d
= 2.25
0.4
0.2 H
c
( Pm v) c
D32
9-17
(9.46)
0.65 0.25
0.6
d
= 1.90
0.4
0.2 H
c
( Pm v) c
(9.47)
9.6.
Gas Hold-Up
ZF ZL
ZF
(9.48)
Vs
Vs + Vt
(9.49)
Akita and Yoshida (1973) correlated the gas hold-up for the absorption of
oxygen in various aqueous solutions in bubble columns, as follows:
1/ 8
g DC2 c
H
=
0.20
4
(1 H )
1/12
3
gDC
c2
Vs
gDC
(9.50)
9-18
gauge
Top View
Side View
4
H =
+(2.1610 ) m 0.6 c
Vt
Vt
(9.51)
where 2.16104 has a unit (m) and Vt = 0.265 m/s when the bubble size is in
the range of 25 mm diameter. The preceding equation can be obtained by
combining Eqs. (9.41) and Eq. (9.45) by means of Eq. (9.37).
For high superficial gas velocities (Vs > 0.02 m/s), replace Pm and Vt of
Eq. (9.51) with effective power input Pe and Vt + Vs, respectively (Miller,
1974).
9.7.
Power Consumption
(9.52)
where N is the agitation speed, and r is the distance from the axis to the point
of the force measurement.
Power consumption by agitation is a function of physical properties,
operating condition, and vessel and impeller geometry. Dimensional analysis
provides the following relationship:
9-19
ND 2 N 2 D D H D
P
I
I
T
W
=
f
,
,
,
,
,...
5
g
DI DI DI
N 3 DI
(9.53)
The dimensionless group in the left-hand side of Eq. (9.53) is known as power
number NP, which is the ratio of drag force on impeller to inertial force. The
first term of the right-hand side of Eq. (9.53) is the impeller Reynolds number
N Rei , which is the ratio of inertial force to viscous force, and the second term
is the Froude number NFr, which takes into account gravity forces. The
gravity force affects the power consumption due to the formation of the
vortex in an agitating vessel. The vortex formation can be prevented by
installing baffles.
For fully baffled geometrically similar systems, the effect of the Froude
number on the power consumption is negligible and all the length ratios in
Eq. (9.53) are constant. Therefore, Eq. (9.53) is simplified to
N P = ( N Re )
(9.54)
(9.55)
D
P
log10 m = 192 I
Pmo
DT
0.115
D 2 N
I
DI N
DI
2 1.96 D
T
ND 3
(9.56)
9-20
10
NP
Propeller
0.1
1.E+00
1.E+01
1.E+02
1.E+03
NRe
1.E+04
1.E+05
1.E+06
Example 9.5
A cylindrical tank (1.22 m diameter) is filled with water to an operating level
equal to the tank diameter. The tank is equipped with four equally spaced
baffles whose width is one tenth of the tank diameter. The tank is agitated
with a 0.36 m diameter flat six-blade disk turbine. The impeller rotational
speed is 2.8 rps. The air enters through an open-ended tube situated below the
impeller and its volumetric flow rate is 0.00416 m 3/s at 1.08 atm and 25C.
Calculate the following properties and compare the calculated values with
those experimental data reported by Chandrasekharan and Calderbank (1981):
Pm = 697 W; H = 0.02; kLa = 0.0217 s1.
a. Power requirement
b. Gas hold-up
c. Sauter-mean diameter
d. Interfacial area
e. Volumetric mass-transfer coefficient
Solution:
a. Power requirement: The viscosity and density of water at 25C is
8.904104 kg/m s (CRC Handbook of Chemistry and Physics , p.
9-21
F-38, 1983) and 997.08 kg/m3 (Perry and Chilton, p. 3-71, 1973),
respectively. Therefore, the Reynolds number is
NDI2 (997.08)(2.8)(0.36) 2
=
= 406,357
8.904 104
N Re =
which is much larger than 10,000, above which the power number is
constant at 6. Thus,
Pmo = 6 N 3 DI5 = 6(997.08)(2.8)3 (0.36)5 = 794 W
The power required in the gas-sparged system is from Eq. (9.56)
4.38
0.36
log10
= 192
1.22
Pmo
Pm
0.115
0.36 (2.8)
8.93107
0.36
1.22
1.96
(0.36)2.8
9.81
0.00416
(2.8)0.363
Therefore,
Pm = 687 W
4Q
4(0.00416)
=
= 0.00356m/s
DT 2
1.222
0.00356 H
H =
0.265
+ 2.16 10
0.071970.6
4
1/ 2
0.00356
0.265
9-22
0.07197 0.6
6 H 6 (0.023)
= 37.7 m1
=
D32 0.00366
9.8.
To estimate the design parameters for oxygen uptake in a fermenter, you can
use the correlations presented in the previous sections, which can be
applicable to a wide range of gas-liquid systems in addition to the air-water
system. However, the calculation procedure is lengthy and the predicted value
from those correlations can vary widely. Sometimes, you may be unable to
find suitable correlations which will be applicable to your type and size of
fermenters. In such cases, you can measure the oxygen-transfer rate yourself
or use correlations based on those experiments.
The oxygen absorption rate per unit volume qa/v can be estimated by
qa
*
*
= K L a(CL CL ) = k L a(CL CL )
v
(9.57)
9-23
Table 9.1
Solubility of Oxygen in Water at 1 atm.a
Temperature
C
0
10
15
20
25
30
35
40
a
Solubility
mmol O2/L
mg O2/L
2.18
1.70
1.54
1.38
1.26
1.16
1.09
1.03
69.8
54.5
49.3
44.2
40.3
37.1
34.9
33.0
minimum air flow rate. To maximize the oxygen absorption rate, we have to
maximize kL, a, CL*CL. However, the concentration difference is quite
limited for us to control because the value of CL* is limited by its very low
maximum solubility. Therefore, the main parameters of interest in design are
the mass-transfer coefficient and the interfacial area.
Table 9.1 lists the solubility of oxygen at 1 atm in water at various
temperatures. The value is the maximum concentration of oxygen in water
when it is in equilibrium with pure oxygen. This solubility decreases with the
addition of acid or salt as shown in Table 9.2.
Normally, we use air to supply the oxygen demand of fermenters. The
maximum concentration of oxygen in water which is in equilibrium with air
CL* at atmospheric pressure is about one fifth of the solubility listed,
according to the Henry's law,
*
CL =
pO2
H O2 (T )
(9.58)
9-24
Data from F. Todt, Electrochemishe Sauer-stoffmessungen, Berlin: W. de Guy & Co., 1958.
CL =
0.209 atm
= 0.264 mmol O 2 / L = 8.43 mg/L
0.793 atm L/mmol
Na 2SO 4
Na 2SO3 + O 2
2
(9.59)
9-25
Example 9.6
To measure kL a, a fermenter was filled with 10 L of 0.5 M sodium sulfite
solution containing 0.003 M Cu++ ion and the air sparger was turned on. After
exactly 10 minutes, the air flow was stopped and a 10 mL sample was taken
and titrated. The concentration of the sodium sulfite in the sample was found
to be 0.21 mol/L. The experiment was carried out at 25C and 1 atm.
Calculate the oxygen uptake and kLa.
Solution:
The amount of sodium sulfite reacted for 10 minutes is
0.5 0.21 = 0.29mol/L
According to the stoichiometric relation, Eq. (9.59) the amount of oxygen
required to react 0.29 mol/L is
9-26
600s
pO2
H O2 (T )
= 8.43104 g/L
7.73103 g/Ls
=
(8.43103 g/L 0)
= 0.917 s1
(9.60)
kL a =
CL* CL (t1 )
ln *
CL CL (t2 )
t2 t1
(9.61)
from which kLa can be calculated based on the measured values of CL(t1) and
CL(t2).
9-27
(9.62)
*
L
(9.63)
(9.64)
(9.65)
9-28
dCL
dt
CL
t
Figure 9.7 Dynamic technique for the determination of kLa.
since kLa in Eq. (9.64) is equal to zero. Therefore, by measuring the slope of
the CL vs. t curve, we can estimate rO2 C X . If you turn on the airflow again, the
dissolved oxygen concentration will be increased according to Eq. (9.64),
which can be rearranged to result in a linear relationship as
*
CL = CL
1 dCL
+
r
C
O2 X
k L a dt
(9.66)
The plot of CL versus dCL / dt + rO2 C X will result in a straight line which has
the slope of 1/(kLa) and the y-intercept of CL*.
9.9.
0.12
0.62
DT
0.17
g 0.93 H 1.1
(9.67)
k L a Pg / v
=
0.08 800
(9.68)
9-29
V
= 800 s
0.1
v
pg
(9.69)
P
k L m
v
(9.70)
The interfacial area for the aerated mixing vessel is a function of agitation
conditions. Therefore, according to Eq. (9.41),
0.4
P
0.5
a m Vs
v
(9.71)
P
k L a m
v
Vs
0.5
(9.72)
Numerous studies for the correlations of kLa have been reported and their
results have the general form as
b
Pm 2 b3
k L a = b1 Vs
v
(9.73)
where b1, b1, and b1 vary considerably depending on the geometry of the
system, the range of variables covered, and the experimental method used.
The values of b2 and b3 are generally between 0 to 1 and 0.43 to 0.95,
respectively, as tabulated by Sideman et al. (1966).
Van't Riet (1979) reviewed the data obtained by various investigators and
correlated them as follows:
1. For coalescing air-water dispersion,
0.4
P
0.5
k L a = 0.026 m Vs
v
(9.74)
9-30
P
0.2
k L a = 0.002 m Vs
v
(9.75)
both of which are applicable for the volume up to 2.6 m3; for a wide variety of
agitator types, sizes, and DI/DT ratios; and 500 < Pm/v < 10,000 W/m3. These
correlations are accurate within approximately 20 percent to 40 percent.
Example 9.7
Estimate the volumetric mass-transfer coefficient kLa for the gas-liquid
contactor described in Example 9.4 by using the correlation for kLa in this
section.
Solution:
From Example 9.4, the reactor volume v is 1.43 m3, the superficial gas
velocity Vs is 0.00356 m/s, and power consumption Pm is 687 W. By
substituting these values into Eq. (9.74),
0.4
687
0.003560.5 = 0.018s1
k L a = 0.026
1.43
9.10. Scale-Up
9.10.1. Similitude
For the optimum design of a production-scale fermentation system
(prototype), we must translate the data on a small scale (model) to the large
scale. The fundamental requirement for scale-up is that the model and
prototype should be similar to each other.
Two kinds of conditions must be satisfied to insure similarity between
model and prototype. They are:
1. Geometric similarity of the physical boundaries: The model and the
prototype must be the same shape, and all linear dimensions of the
model must be related to the corresponding dimensions of the prototype
by a constant scale factor.
9-31
(9.76)
where du/dy is velocity gradient and A is the area on which the viscosity force
acts. For the agitating system, the fluid dynamics involved are too complex to
calculate a wide range of velocity gradients present. However, it can be
assumed that the average velocity gradient is proportional to agitation speed N
and the area A is to DI2, which results.
FV NDI
(9.77)
Pmo
DI N
(9.78)
FG DI g
(9.79)
F = F
+ FD + FG = FI DI N 2
4
(9.80)
Then dynamic similarity between a model (m) and a prototype (p) is achieved
if
( FV )m ( FD )m ( FG )m ( FI )m
=
=
=
( FV ) p ( FD ) p ( FG ) p ( FI ) p
(9.81)
9-32
or in dimensionless forms:
FI FI
=
F F
V p
V m
FI FI
=
FD FD
p
m
(9.82)
FI
= FI
F
G p
G m
DI N 2 DI N
FI
=
=
= N Rei
2
FV
NDI
4
(9.83)
DI N 2
N 3 DI
FI
1
=
=
=
FV
Pmo / DI N
Pmo
NP
(9.84)
DI N 2 DI N 2
FI
=
=
= N Fr
3
FG
g
DI g
(9.85)
(9.86)
( N Fr ) p = ( N Fr ) m
Therefore, using dimensionless parameters for the correlation of data has
advantages not only for the consistency of units, but also for the scale-up
purposes.
However, it is difficult, if not impossible, to satisfy the dynamic similarity
when more than one dimensionless group is involved in a system, which
creates the needs of scale-up criteria. The following example addresses this
problem.
9-33
Example 9.8
The power consumption by an agitator in an unbaffled vessel can be
expressed as
ND 2 N 2 D
P
I
I
= f
,
5
3
g
N DI
Can you determine the power consumption and impeller speed of a
1,000-gallon fermenter based on the findings of the optimum condition from a
geometrically similar one-gallon vessel? If you cannot, can you scale up by
using a different fluid system?
Solution:
Since Vp /Vm = 1,000, the scale ratio is,
( DI ) p
( DI ) m
=1,0001/ 3 =10
(9.87)
N 3 D 5 N 3 D 5
I
I
p
m
(9.88)
ND 2
ND 2
I
I
=
p
m
(9.89)
N 2 DI N 2 DI
g p g m
(9.90)
If you use the same fluid for the model and the prototype, p = m and p =
m. Canceling out the same physical properties and substituting Eq. (9.87) to
Eq. (9.88) yields
N
( Pmo ) p = 10 ( Pmo ) m p
N
5
(9.91)
(9.92)
9-34
1
Nm
10
(9.93)
which is conflicting with the previous requirement for the equality of the
Reynolds number. Therefore, it is impossible to satisfy the requirement of the
dynamic similarity unless you use different fluid systems.
If p m and p m , to satisfy Eqs. (9.89) and (9. 90), the following
relationship must hold.
= 1
m 31.6 p
(9.94)
N 3 D 5 N 3 D 5
I
I
p
m
(9.95)
If the fluid employed for the prototype and the model remains the same,
the power consumption in the prototype is
N
( Pmo ) p = ( Pmo )m p
N m
( DI )
m
(D )
I p
9-35
(9.96)
where (DI)p/(DI)m is equal to the scale ratio. With a known scale ratio and
known operating conditions of a model, we are still unable to predict the
operating conditions of a prototype because there are two unknown variables,
Pmo and N. Therefore, we need to have a certain criteria which can be used as
a basis.
DI 3 DI 3 N m ( DI )m
p
m
(9.97)
Note that Pmo/DI3 represents the power per volume because the liquid volume
is proportional to DI3 for the geometrically similar vessels. For the constant
Pmo/DI3,
3
N p ( DI )m
=
N ( D )
m
I p
(9.98)
2/3
N m = 0.34 N m
(9.99)
which shows that the impeller speed in a prototype vessel is about one third of
that in a model. For constant Pmo/v, the Reynolds number and the impeller tip
speed cannot be the same. For the scale ratio of 5,
( N Rei ) p = 8.5( N Rei )m
(9.100)
(9.101)
9-36
Model
20 gal
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
125.
1.0
0.34
5.0
42.5
0.34
1.7
8.5
Prototype
2,500 gal
3126
25
25
0.2
1.0
0.2
5.0
5.0
125
25
0.2
1.0
5.0
1.0
25
5.0
0.2
0.0016
0.04
5.0
5.0
0.04
0.2
1.0
9-37
Agitation Intensity
Mild
23
Vigorous
4 10
Intense
9-38
animal cells (Croughan et al., 1987), and plant cells (Hooker et al., 1988).
Shear also is responsible for the deactivation of enzymes (Charm and Wong,
1970). As a result, for optimum operation of an agitated fermentation system,
we need to understand the hydrodynamics involved in shear sensitive mixing.
For the laminar flow region of Newtonian fluid, shear stress is equal to
the viscosity times the velocity gradient du/dy as
du
dy
(9.102)
du
dy
(9.103)
where is eddy viscosity, which is not only dependent upon the physical
properties of the fluid, but also the operating conditions. Therefore, to
describe the intensity of shear in a turbulent system such as an agitated
fermenter, it is easier to estimate shear rate du/dy instead of shear stress.1
Even though we use the shear rate as a measure of the shear intensity, we
should remember that it is the shear stress that ultimately affects the living
cells or enzyme. Depending upon the magnitude of viscosity and also whether
the flow is laminar or turbulent, there is a wide range of shear stress generated
for the same shear rate. However, the shear rate is a good measure for the
intensity of the agitation.
In agitated systems, it is difficult, if not impossible, to determine the shear
rate, because of the complicated nature of the fluid dynamics generated by
impellers. A fluid element in an agitated vessel will go through a wide range
of shear rates during agitation: maximum shear when it passes through the
impeller region and minimum shear when it passes near the corner of the
vessel. Metzner and Otto (1957) developed a general correlation for the
average shear rate generated by a flat-blade disk turbine, based on power
measurements on non-Newtonian liquids, as:
For a non-Newtonian fluid, the viscosity is not constant even for the laminar flow.
Therefore, shear rate is easier to estimate than shear stress.
9-39
(9.104)
av
9.12. Nomenclature
A
a
a0
b
C
CD
DAB
!
DAB
D32
DI
DT
DW
F
JA
K
k
g
H
N
NA, NB
NFr
NG, NL
interfacial area, m2
gas-liquid interfacial area per unit volume of dispersion for low
impeller Reynolds numbers, m1
gas-liquid interfacial area per unit volume of dispersion, m1
constant
concentration, kmol/ m3
friction factor and drag coefficient, dimensionless D diameter of
bubble or solid particle, m
diffusivity of component A through B, m2/s
diffusivity of component A in a very dilute solution of B, m2/s
Sauter-mean diameter, m
impeller diameter, m
tank diameter, m
impeller width, m
force, N
molar flux of component A relative to the average molal velocity
of all constituents, kmol/ m2s
overall mass-transfer coefficient, m/s
individual mass-transfer coefficient, m/s
acceleration due to gravity, m/s2
volume fraction of gas phase in dispersion, dimensionless
impeller speed, s -1
mass flux of A and B relative to stationary coordinate, kmol/ m2s
Froude number (DIN2/g),dimensionless
mass flux from gas to liquid phase and from liquid to gas phase,
respectively, kmol/m2s
NGr
No
9-40
NP
NReb
N Rei
NSc
NSh
P
Pe
Pg
Pm
Pmo
q
Q
R
r
s
te
u
uo
Vs
Vt
v
ZF, ZL
zf
(t)
9-41
absolute pressure, N/ m2
pressure at sparger, N/ m2
density, kg/m 3
surface age distribution function
surface tension, kg/s2
shear stress, N/ m2
SUBSCRIPT
c
d
G
g
L
9.13. Problems
9.1 Derive the relationship between the overall mass transfer coefficient
for gas phase KG and the individual mass-transfer coefficients, kL and
kG. How can this relationship be simplified for sparingly soluble
gases?
9.2 Prove that Eq. (9.27) is the same with Eq. (9.28), and Eq. (9.30) is the
same with Eq. (9.31).
9.3 The power consumption by impeller P in geometrically similar
fermenters is a function of the diameter DI and speed N of impeller,
density and viscosity of liquid, and acceleration due to gravity g.
Determine appropriate dimensionless parameters that can relate the
power consumption by applying dimensional analysis using the
Buckingham-Pi theorem.
9.4 A cylindrical tank (1.22 m diameter) is filled with water to an
operating level equal to the tank diameter. The tank is equipped with
four equally spaced baffles, the width of which is one tenth of the
tank diameter. The tank is agitated with a 0.36 m diameter, flat-blade
disk turbine. The impeller rotational speed is 4.43 rps. The air enters
through an open-ended tube situated below the impeller and its
volumetric flow rate is 0.0217 m3/s at 1.08 atm and 25C. Calculate:
9-42
= f
5
3
N DI
Can you determine the power consumption and impeller speed of a
1,000-gallon fermenter based on findings of the optimum condition
from a one-gallon vessel by using the same fluid system? Is your
conclusion reasonable? Why or why not?
9.7 The optimum agitation speed for the cultivation of plant cells in a 3-L
fermenter equipped with four baffles was found to be 150 rpm.
a. What should be the impeller speed of a geometrically similar
1,000 L fermenter if you scale up based on the same power
consumption per unit volume.
b. When the impeller speed suggested by part (a) was employed for
the cultivation of a 1,000-L fermenter, the cells do not seem to
grow well due to the high shear generated by the impeller even
though the impeller speed is lower than 150 rpm of the model
system. This may be due to the higher impeller tip speed which is
proportional to NDI. Is this true? Justify your answer with the ratio
of the impeller tip speed of the prototype to the model fermenter.
c. If you use the impeller tip speed as the criteria for the scale-up,
what will be the impeller speed of the prototype fermenter?
9-43
9.8 The typical oxygen demand for yeast cells growing on hydrocarbon is
about 3 g per g of dry cell. Design a 10-L stirred fermenter (the
diameter and height of fermenter, the type and diameter of impeller)
and determine its operating condition (impeller speed and aeration
rate) in order to meet the oxygen demand during the peak growth
period with the growth rate of 0.5 g dry cell per liter per hour. You
can assume that the physical properties of the medium is the same as
pure water. You are free to make additional assumptions in order to
design the required fermenter.
9.14. References
Akita, K. and F. Yoshida, Gas Holdup and Volumetric Mass Transfer
Coefficient in Bubble Column, I&EC Proc. Des. Dev. 12 (1973):76
80.
Akita, K. and F. Yoshida, Bubble Size, Interfacial Area, and
Liquid-Phase Mass Transfer Coefficient in Bubble Columns, I&EC
Proc. Des. Dev. 13 (1974):8491.
Botton, R., D. Cosserat, and J. C. Charpentier, Operating Zone and Scale
Up of Mechanically Stirred Gas-Liquid Reactors, Chem. Eng. Sci. 35
(1980):8289.
Bowen, R. L., Unraveling the Mysteries of Shear-sensitive Mixing
Systems, Chem. Eng. 9 (1986):5563.
Calderbank, P. H., Physical Rate Processes in Industrial Fermentation,
Part I: Interfacial Area in Gas-Liquid Contacting with Mechanical
Agitation, Trans. Instn. Chem. Engrs. 36 (1958):443459.
Calderbank, P. H., Physical Rate Processes in Industrial Fermentation,
Part II: Mass Transfer Coefficients in Gas-Liquid Contacting with and
without Mechanical Agitation, Trans. Instn. Chem. Engrs. 37
(1959):173185.
Calderbank, P. H. and S. J. R. Jones, Physical Rate Properties in
Industrial Fermentation Part III. Mass Transfer from Fluids to Solid
Particles Suspended in Mixing Vessels, Trans. Instn. Chem. Engrs. 39
(1961):363368.
Calderbank, P. H. and M. B. Moo-Young, The Continuous Phase Heat
and Mass-Transfer Properties of Dispersions, Chem. Eng. Sci. 16
(1961):3954.
9-44
9-45