TABT0600393EN00
Subject: C2403 after installing the countermeasure part
Product Name: bizhub 420/500
Date: October 16, 2006
Pull out and put in the bottle tray at slightly moved position.
Pull out the tray and rotate the bottle
half or quarter way clockwise.
Result display
When pulling out: 0
When putting in: 1
If the display does not switch from 0 to 1
and remains 0 or 1 during this check, the
sensor detects wrongly.
It is preferable to remove also the drum cartridge and the developing unit.
(2) Remove the control board unit.
* Clean the metal that holds the bottle tray and the bottle tray surface before cleaning the sensor.
(5) Check the sensor installation condition.
With this state, install the control board unit (not fix it with screws, just hook the upper part and connect the connector).
Enter the service mode and perform the sensor check.
If the sensor does not operate correctly after cleaning, replace the sensor.
<> Replace the sensor.
Remove the finisher, paper exit tray and other.
Remove the write unit top plate and the fusing fan installation metal.
It is preferable to remove also the fusing unit,
though it is possible to remove the parts just
by removing a screw and making the unit
loose.