* MASS GENERATION DATA FOR LATERAL ANALYSIS OF BUILDING

_________________________________________________________
STORY
TRANSLATIONAL MASS
NAME
(X-DIR)
(Y-DIR)
----------- ----------- ----------Roof
27804.614
27804.614
2F 35476.7542 35476.7542
1F
0.0
0.0
----------- ----------- ----------TOTAL :
63281.3682 63281.3682

ROTATIONAL
MASS
----------2194227.52
2836811.94
0.0
-----------

[UNIT: kgf, m]

CENTER OF MASS
(X-COORD)
(Y-COORD)
----------- ----------7.21876028 11.9201177
7.21899678 11.8640136
0.0
0.0
----------- -----------

* ADDITIONAL MASSES FOR THE CALCULATION OF EQUIVALENT SEISMIC FORCE


_____________________________________________________________________
Note. The following masses are between two adjacent stories or on the
nodes released from floor rigid diaphragm by *Diaphragm Disconnect command.
The masses are proportionally distributed to upper/lower stories according
to their vertical locations. For dynamic analysis, however, floor masses
and masses on vertical elements remain at their original locations.
STORY
NAME
-------------Roof
2F
1F
-------------TOTAL :

TRANSLATIONAL MASS
(X-DIR)
(Y-DIR)
----------- ----------0.0
0.0
0.0
0.0
1734.65225 1734.65225
----------- ----------1734.65225 1734.65225

* EQUIVALENT SEISMIC LOAD IN ACCORDANCE WITH EUROCODE-8(2004)


[UNIT: kgf,
m]
___________________________________________________________________________
Ground Type
Spectrum Type
Soil Class Factor (S)
Limits of Constant Spectral Acceleration Branch (Tb)
Limits of Constant Spectral Acceleration Branch (Tc)
Start of Constant Displacement Range of Spectrum (Td)
Design Ground Acceleration (Ag)
Behavior Factor (q)
Lower Bound Factor (b)
Importance Factor (I)
Correction Factor for X-direction (Lambda_x)
Correction Factor for Y-direction (Lambda_y)
Fundamental Period for X-direction (T1x)
Fundamental Period for Y-direction (T1y)
Ordinate of Design Spectrum at Period T1x (Sd(T1x))
Ordinate of Design Spectrum at Period T1y (Sd(T1y))

:
:
:
:
:

:
:
:
:

: B
: Type1
1.20
0.15
0.50
2.00
: 0.08
1.50
: 0.20
: 1.00
: 1.00
: 1.00
0.0000
0.0000
0.0640
0.0640

Total Effective Weight For X-dir. Seismic Loads (Wx)


Total Effective Weight For Y-dir. Seismic Loads (Wy)

: 620537.097000
: 620537.097000

Scale Factor For X-directional Seismic Loads


Scale Factor For Y-directional Seismic Loads

: 1.00
: 1.00

Accidental Eccentricity For X-direction (Ex)

: Positive

Accidental Eccentricity For Y-direction (Ey)

: Positive

Torsional Amplification for Accidental Eccentricity


Torsional Amplification for Inherent Eccentricity

: Do not Consider
: Do not Consider

Total Base Shear Of Model For X-direction


: 39714.374208
Total Base Shear Of Model For Y-direction
: 39714.374208
Summation Of Wi*Zi Of Model For X-direction
: 3071631.588000
Summation Of Wi*Zi Of Model For Y-direction
: 3071631.588000
------------------------------------------------------------------------------------===========================
ECCENTRICITY RELATED DATA
===========================
T I O N A L

X - D I R E C T I O N A L
L O A D

L O A D

Y - D I R E C

STORY ACCIDENTAL INHERENT ACCIDENTAL INHERENT


ACCIDENTAL INHERENT
ACCIDENTAL INHERENT
NAME
ECCENT.
ECCENT.
AMP.FACTOR AMP.FACTOR
ECCENT.
ECCENT.
AMP.FACTOR AMP.FACTOR
---------- ---------- ---------- ---------- ------------------- --------- ---------- ---------Roof
0.0
0.0
1.0
0.0
0.0
0.
0
1.0
0.0
2F
0.0
0.0
1.0
0.0
0.0
0.
0
1.0
0.0
G.L
0.0
0.0
0.0
0.0
0.0
0.
0
0.0
0.0
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------The accidental amplification factors are automatically set to 1.0 when torsional
amplification effect
to accidental eccentricity is not considered.
The inherent amplification factors are automatically set to 0 when torsional amp
lification effect
to inherent eccentricity is not considered.
The inherent amplification factors are all set to 'the input value - 1.0'.(This
is to exclude the true
inherent torsion)
-----------------------------------------------------------------------------------------------------** Story Force , Seismic Force x Scale Factor + Added Force
S E I S M I C

L O A D

G E N E R A T I O N

D A T A

X - D I R E

C T I O N
STORY STORY STORY SEISMIC
NT. INHERENT TOTAL
NAME
WEIGHT LEVEL FORCE
N TORSION
TORSION

ADDED

STORY

STORY

OVERTURN. ACCIDE

FORCE

FORCE

SHEAR

MOMENT

TORSIO

---------- -------- ------- -------- -------- -------- -------- --------- -------- --------- --------Roof 272652.0
6.8 23971.56
0.0 23971.56
0.0
0.0
0.0
0.0
0.0
2F 347885.1
3.5 15742.82
0.0 15742.82 23971.56 79106.14
0.0
0.0
0.0
G.L.
-0.0
---39714.37 218106.5
-----------------------------------------------------------------------------------------------------------S E I S M I C

L O A D

G E N E R A T I O N

D A T A

Y - D I R E

C T I O N
STORY STORY STORY SEISMIC ADDED
STORY
STORY OVERTURN. ACCIDE
NT. INHERENT TOTAL
NAME
WEIGHT LEVEL FORCE
FORCE
FORCE
SHEAR MOMENT
TORSIO
N TORSION
TORSION
---------- -------- ------- -------- -------- -------- -------- --------- -------- --------- --------Roof 272652.0
6.8 23971.56
0.0 23971.56
0.0
0.0
0.0
0.0
0.0
2F 347885.1
3.5 15742.82
0.0 15742.82 23971.56 79106.14
0.0
0.0
0.0
G.L.
-0.0
---39714.37 218106.5
-----------------------------------------------------------------------------------------------------------=================================================
COMMENTS ABOUT TORSION
=================================================
-----------------------------------------------------------------------------------------------------If torsional amplification effects are considered :
-----------------------------------------------------------------------------------------------------Accidental Torsion , Story Force * Accidental Eccentricity * Amp. Factor for Acc
idental Eccentricity
Inherent Torsion , Story Force * Inherent Eccentricity * Amp. Factor for Inher
ent Eccentricity
-----------------------------------------------------------------------------------------------------If torsional amplification effects are not considered :
-----------------------------------------------------------------------------------------------------Accidental Torsion , Story Force * Accidental Eccentricity
Inherent Torsion , 0
-----------------------------------------------------------------------------------------------------The inherent torsion above is the additional torsion due to torsional amplificat
ion effect.
The true inherent torsion is considered automatically in analysis stage when the
seismic force is
applied to the structure.
--------------------------------------------------------------------------------

-----------------------

Das könnte Ihnen auch gefallen