Record Detail with Inspection Log


Record ID: SE1600489
Description: Install 5KW ballasted roof mounted solar PV system for
SFD.
APN: 037A273402200
Address: 6120 CAMDEN ST
Unit #:

Date Opened: 6/7/2016


Record Status: Final
Record Status Date: 7/22/2016
Job Value: $1,001.00
Requestor: PIRIE RUTH & MARK S
:
Business Name:
License #:
Inspection Date
7/22/2016

Inspector Name
Alan Albee

Inspection Type
Final Electrical

Status / Result
Pass

Result Comments
Date: 7/22/2016 Final OK

For real-time, direct access to information via the Internet, 24 hours a day - https://aca.accela.com/oakland

Page 1

Record Detail with Inspection Log


Record ID: RP1600861
Description: Replace water heater and gas range including re-piping,
and gas test for new meter for SFD. PG&E application #11499626. 0516-16 add to scope of work sink, dishwasher, clothes washer, and
water alteration.
APN: 037A273402200
Address: 6120 CAMDEN ST
Unit #:

Date Opened: 4/1/2016


Record Status: Final
Record Status Date: 10/21/2016
Job Value: $0.00
Requestor: PIRIE RUTH & MARK S
:
Business Name:
License #:
Inspection Date

Inspector Name

Inspection Type

5/18/2016

Robert Bernal

Frame

5/24/2016

Robert Bernal

Frame

5/25/2016
9/26/2016

David Carrillo
Robert Bernal

Frame
Final Plumbing

10/5/2016
10/18/2016

Reynaldo Jimenez
Greg Clarke

Final Plumbing
Final Plumbing

Status / Result

Result Comments

Partial

Date: 5/18/2016 Gas pipe is OK pending removal of union


located in the underfloor area towards the front of the
house with a gas pipe leak test T/C at these two joints.
Gas pressure test and meter reset is OK.
Partial
Date: 5/24/2016 Waterpipe OK, for DWV approval water
test the laundry standpipe and vent, CO to come for the
laundry standpipe. For gas pipe approval and pressure
test approval the left right nipple needs testing at the
front of the house. For tankless water heater approval the
condensate line is required per the typical installation in
the manual.
Pass
Date: 5/25/2016 Final ok. DCC
Partial
Date: 9/26/2016 For final the dryer duct is required to be
solid smooth walled duct with no screws.
Cancelled In Office CANCELLED IN OFFICE 10/5/2016 1:29AM.
Not Pass
Date: 10/18/2016 10-17-16: no one at job site

For real-time, direct access to information via the Internet, 24 hours a day - https://aca.accela.com/oakland

Page 2
License #:
Inspection Date
10/21/2016

Inspector Name

Inspection Type

Status / Result

Greg Clarke

Final Plumbing

Pass

Greg Clarke

Final Plumbing

Scheduled

Result Comments
Date: 10/21/2016 10-21-16: plumbing final okay. Items
on C/N corrected

For real-time, direct access to information via the Internet, 24 hours a day - https://aca.accela.com/oakland

Page 1

Record Detail with Inspection Log


Record ID: RE1601089
Description: Install 200 amp main service upgrade for SFD. Includes
replacing receptacles throughout house. PG&E application #11415631.
APN: 037A273402200
Address: 6120 CAMDEN ST
Unit #:

Date Opened: 4/1/2016


Record Status: Final
Record Status Date: 10/21/2016
Job Value: $0.00
Requestor: PIRIE RUTH & MARK S
:
Business Name:
License #:
Inspection Date

Inspector Name

Inspection Type

4/28/2016

Alan Albee

Frame

5/16/2016

David Carrillo

Frame

5/24/2016

Robert Bernal

Frame

9/26/2016

Robert Bernal

Final Electrical

10/5/2016
10/18/2016
10/18/2016
10/21/2016

Reynaldo Jimenez
Greg Clarke
Greg Clarke
Greg Clarke

Final
Final
Final
Final

Electrical
Electrical
Electrical
Electrical

Status / Result

Result Comments

Not Pass

Date: 4/28/2016 Information only, not ready for


approvals.
Pass
Date: 5/16/2016 200 amp "u" release, interior re-wire on
separate permit. See bonding at water heater, lockout
and crimp for final to come. DCC app# 111415631
Partial
Date: 5/24/2016 Cable runs in walls are OK to cover,
under floor clean up of sagging cable runs and main
panel tie-in is T/C.
Partial
Date: 9/26/2016 For final: 1. By the electrical panel, open
J box requires a cover. 2. By the electrical panel, open
spices are required to be inside of a J box. 3. At the
receptacle by the electrical panel, the Romax jacket is
required to extend into the J box. 4. Three wire circuits
are required to be identified in the service panel with a
reinspection to follow.
Cancelled In Office CANCELLED IN OFFICE 1:31PM 10/4
Not Pass
Date: 10/18/2016 10-17-16: no one at job site
Cancelled In Office Date: 10/18/2016 10-18-16: canceled in office
Pass
Date: 10/21/2016 10-21-16: electrical final okay. Items

For real-time, direct access to information via the Internet, 24 hours a day - https://aca.accela.com/oakland

Page 2
License #:
Inspection Date

Inspector Name

Inspection Type

Status / Result

Result Comments
on C/N corrected

For real-time, direct access to information via the Internet, 24 hours a day - https://aca.accela.com/oakland