Sie sind auf Seite 1von 7

Edmonton Terminal (South) Expansion

Technical Description
Pipeline Filing Requirements
Manifold 203 Discharge

Manifold 217 Discharge

WPE

Road
Bore

Road Bore to
Valve Manifold

Tight Line into


E2H Pipeline

Tight Line Tee to Valve


Manifold

Tee to CTM

Metering

CTM to Valve
Manifold

36

36

36

36

36

16

36

Outside Diameter (mm)

914.0

914.0

914.0

914.0

914.4

406.4

914.4

Wall Thickness (mm)

19.05

12.70

12.70

12.70

9.52

9.52

9.52

GR 448

GR 359

GR 359

GR 359

GR 241

GR 241

GR 241

PN 50

PN 50

PN 50

PN 50

PN 20

PN 20

PN 20

MOP (kPag)

4960

4960

4960

4960

1900

1900

1900

Approximate Length (m)

876

230

180

52

25

105

35

Piping Size (NPS)

Grade/Class

Depth of Burial
Coatings

Min 0.6m to top of pipe as per Enbridge Specification D02-103 - 2011


Above Grade painted as per Enbridge P-210*; Below grade coated as per Enbridge C-110*

Tank Lines
Tank 303

Tank 304

Tank 305

Tank 306

Tank 307

Tank 308

Tank 309

48

48

48

48

48

48

48

Outside Diameter (mm)

1219.0

1219.0

1219.0

1219.0

1219.0

1219.0

1219.0

Wall Thickness (mm)

10.31

10.31

10.31

10.31

10.31

10.31

10.31

GR 241

GR 241

GR 241

GR 241

GR 241

GR 241

GR 241

PN 20

PN 20

PN 20

PN 20

PN 20

PN 20

PN 20

MOP

1900

1900

1900

1900

1900

1900

1900

Approximate Length
(m)

360

345

360

225

95

110

100

Piping Size (NPS)

Grade/Class

Depth of Burial
Coatings

Min 0.6m to top of pipe as per Enbridge Specification D02-103-2011


Above Grade painted as per Enbridge P-210*; Below grade coated as per Enbridge C-110*

BP Discharge

Surge Relief System

Valve
Manifold
to BP
Suction

To E2H
MLP
Suction

To L4
Road
Bore

L4 Road
Bore

To L4
MLP
Suction

Storm Water
Pond Drain
Line

WPE to
Common
Relief Line

Mainline
Pump
Suction to
Common
Relief Line

Common
Relief
Line

Common
Relief Line
to Tank 306

Common
Relief
Line to
Tank 307

Piping Size (NPS)

42

36

36

36

36

12

24

24

24

24

24

Outside Diameter
(mm)

1067.0

914.0

914.0

914.0

914.0

323.9

609.6

609.6

609.6

609.6

609.6

9.52

12.70

12.70

12.70

12.70

17.48

9.52

9.52

9.52

9.52

9.52

GR 241

GR 359

GR 359

GR 448

GR 359

GR 241

GR 241

GR 241

GR 241

GR 241

GR 241

PN 20

PN 50

PN 50

PN 50

PN 50

PN 20

PN 20

PN 20

PN 20

PN 20

PN 20

MOP (kPag)

1900

4960

4960

4960

4960

1900

1900

1900

1900

1900

1900

Approximate
Length (m)

110

35

340

905

220

20

110

25

190

55

45

Wall Thickness
(mm)
Grade/Class

Depth of Burial
Coatings

Min 0.6m to top of pipe as per Enbridge Specification D02-103-2011


Above Grade painted as per Enbridge P-210*; Below grade coated as per Enbridge C-110*

Product Carried:
Heavy Crude Oil
Description of Flaring System:
N/A
Corrosion Control Elements:
Cathodic protection for underground piping
Crossings:
Enbridge has initiated the process of identifying potential pipeline crossings in the vicinity of the work area at the Edmonton Terminal (North) &
Edmonton Terminal (South) facilities. Any required crossing agreements will be in place prior to construction.
Description of corrosion control elements:
External coatings will be applied as per Enbridges Coating Specifications C-110: Coating of Buried Steel with Plural-Component Spray Applied
Coatings for the terminal and C-010: External Fusion Bonded Epoxy Coating for the transfer lines.
Cathodic Protection will be used on underground piping and structural piles. This will be achieved utilizing Anode rods, with an applied DC current
supplied via rectifiers. The cathodic protection for tank bottoms will be achieved with anode ribbons buried beneath the floor.

Pump Facilities Filing Requirements


Technical Detail
Type and power of pumps
Fuel type and source of pumps
Piping outside diameter, wall thickness,
material type and grade
MOP, inlet and outlet design pressures
Inlet and outlet temperature

Centrifugal
Electric up to 4000 HP
N/A
Suction: NPS 36, 9.52 mm, carbon steel, grade 241
Discharge: NPS 36, 12.7 mm, carbon steel, grade 359
Suction flange & piping will be designed to be a PN 20 system
Discharge flange & piping will be designed to be a PN 50 system
Fluid temperature range is 0oC to 38oC

Description of surge control system, pressure control and overpressure control:


For the incoming shipper line, surge control will be via a pressure safety valve (ex Danflo valve) in the event of a PCV failure. The surge relief
line will have connections to two atmospheric tanks that will be designated to receive relief product.
Basic description of emergency shutdown:
Automatic shutdown of critical valves and process pumps
Description of boilers and pressure vessels:
N/A

Metering Stations Filing Requirements


Description of Analysis System:
Flow Rates & Pressures
Parameter

Minimum Value

Maximum Value

Flow Rate (per meter) [m3/hr]

397

1590

Flow Rate (entire manifold) [m3/hr]

2450

7066

Inlet Pressure [kPag]

441

517

Outlet Pressure[kPag]

303

362

Meter Type & Number:


A.O. Smith brand M-16
Six (6) meters incoming shipper
Method for Regulating/Metering:
As per Enbridges Design Standard D09-104: Custody Transfer Metering Systems

Liquid Tanks Facilities Filing Requirements


Requirements of Pipelines to be entered in Pipeline table
Tank 01

Tank 02

Tank 03

Tank 04

Tank 05

Nominal Capacity (m3)

88481

88481

88481

88481

88481

Working Capacity (m3)

80000

80000

80000

80000

80000

Maximum Injection (m3/hr)

7066

7066

7066

7066

7066

Takeaway Flow Rates (m3/hr)

5888

5888

5888

5888

5888

Description of containment and overflow prevention system:


Overflow protection will be as per Enbridges Technical Standards Preferred Practice TSP-002-2004: Tank Overflow Slots, where redundant
instrumentation [will]be installed and maintained to prevent tank overfill from occurring.
Containment will be as per National Fire Protection Association (NFPA) 30, Albertas Energy Resources Conservation Board (ERCB) Directive 055
and all applicable National Energy Board (NEB) regulations.
Description of overpressure system:
As per American Petroleum Institute (API) 650

Das könnte Ihnen auch gefallen