TechNote:TheCPA50EandSwirl
WhatisSwirl?
Swirlcanbedefinedasahelicalflowpatternwithinapipe,whereby
thereisacomponenttothegasvelocityvectorthatisperpendicular
tothelongitudinalaxisofthepipe.Thereareanumberofpossible
causesofswirlinapipingsystem.Someoftheseare:
Multipleelbowsortees
Mixers
Compressors
The CPA 50E is 0.12 to 0.15 pipe diameters thick. The holes are
sizedtotheinsidediameterofthepipetoproducefullydeveloped
flowathighPipeReynoldsNumber(~106).
SwirlandOrificeMeters
HowCanThisSinglePlateEliminateSwirl?
Therearetwoeffectswhichcombineasthefluidpassesthroughthe
plate. The first is the acceleration of the gas to over twice the
averagevelocityinthepipe.Theflowisalsosplitinto25streams,
each passing through a hole which is approximately 1 diameter
long.These2effectswilltendtostraightentheflow.
Swirlwillgenerallyhaveagreaterimpactonlowerbetaratios.At
high swirl angles (over 20 degrees) and with Beta ratios up to 0.4,
meter error can be in the 10% range (1). This effect of swirl will
reduceasswirlangleisreduced.
TwodegreesofswirlistheacceptableupperlimitspecifiedbyISO
5167.Miller(2)statesthattubebundlesreduceswirlto2orless.
This limit of 2 is likely due to both the lack of impact of this
amount of swirl has on the meter, as well as the difficulty of
measuringsmalleramounts.
Data was gathered on high swirl in bare meter tubes (no flow
conditioner). On a 17D meter run, with a swirl generator and tee
upstream,theerrorfora0.4betaratioplatewas5to6percent(in
linewithKinghorn).
CanaCPA50EEliminateSwirl?
CanadaPipelineAccessories
18883493569www.flowconditioner.com
November2008
TechNote:TheCPA50EandSwirl
1.00%
0.80%
0.60%
0.40%
0.20%
0.00%
-0.20%
-0.40%
-0.60%
-0.80%
-1.00%
Tap 1
Tap 2
11
13
1.00%
0.80%
0.60%
0.40%
0.20%
0.00%
-0.20%
-0.40%
-0.60%
-0.80%
-1.00%
Tap 1
Tap 2
Therearesomeimportantpointstonotefromthisdata:
Thedeviationfromthebaselineisverygood
Thebetaratioandupstreamconditionsmakethistestthemost
extremeswirltestconducted
Atestwithtwo elbowsoutofplane(lesssevereswirl)yielded
similarresults
11
13
Conclusions
TheevidenceavailableindicatesthattheCPA50Eflowconditioner
isolates the meter run from a wide variety of upstream
configurations, and helps produce excellent metering under all
conditions.
Thereisnoevidencethatanyswirlhaspassedtheflowconditioner.
Testing at higher beta ratios yields similar results for the range of
upstreampipingconfigurationstested.
References:
Forexample,thetwoelbowsoutofplaneresultsforbeta0.67ona
17diametermeterrunareshownhere.
Pointstonotefromthisdatainclude:
Similarresultsareachieved,independentofupstreampiping
1.
2.
3.
CanadaPipelineAccessories
18883493569www.flowconditioner.com