Beruflich Dokumente
Kultur Dokumente
56.0
Publication Plumbing 04
2011
PLUMBING
WHITESPEED GPF INTERLOCK TANKS
unimer
CUSTOMER
WHITESPEED PIPE
70.00%
70.00%
GPF PIPE
70.00%
70.00%
INTERLOCK PIPE
INTERLOCK FITTINGS
70.00%
70.00%
CONTENTS
Page
WHITESPEED PIPE
3, 4, 5, 6, 7, 8
GPF PIPE
12
INTERLOCK PIPE
21
INTERLOCK FITTINGS
21, 22, 23
Davant Whitespeed
Demountable Plastic Plumbing System
Polybutylene Pipe and Fittings
1. BARRIER PIPE - COILS
Code
Size
Pack Qty
Price (each)
KDBC10/100
141.63
KDBC10/50
70.81
KDBC10/25
39.33
KDBC15/100
163.67
KDBC15/150
245.51
KDGBC15/50
93.35
KDGBC15/30
49.09
KDGBC15/25
40.92
KDGBC15/15
24.54
KDBC22/50
160.58
KDGBC22/30
96.32
KDGBC22/25
80.26
KDGBC22/15
48.17
Size
Pack Qty
Price (each)
KDBL15/5
20
9.83
KDBL15/3
15mm x 3m Lengths
20
4.91
KDBL22/5
10
19.26
KDBL22/3
22mm x 3m Lengths
10
9.64
KDBL28/5
26.44
KDBL28/3
28mm x 3m Lengths
13.17
3. STRAIGHT COUPLER
Code
Size
Pack Qty
Price (each)
KDSC10
10mm
10
2.15
KDSC15
15mm
10
1.60
KDSC22
22mm
2.53
KDSC28
28mm
6.66
4. STRAIGHT REDUCER
Code
Size
Pack Qty
Price (each)
KDSR1510
15mm x 10mm
10
3.74
KDSR2215
22mm x 15mm
10
4.40
5. SOCKET REDUCER
Code
Size
Pack Qty
Price (each)
KDSKR1510
15mm x 10mm
10
1.81
KDSKR2215
22mm x 15mm
10
2.38
KDSKR2822
28mm x 22mm
10
5.36
6. ELBOW
Code
Size
Pack Qty
Price (each)
KDE10
10mm
10
2.61
KDE15
15mm
10
1.86
KDE22
22mm
10
2.99
KDE28
28mm
10
7.40
www.davant.co.uk
Davant Whitespeed
Demountable Plastic Plumbing System
Fittings
1. TEE
Code
Size
Pack Qty
Price (each)
KDT10
10mm
10
3.01
KDT15
15mm
10
2.72
KDT22
22mm
10
4.04
KDT28
28mm
10.45
2. REDUCING TEE
Code
Size
Pack Qty
Price (each)
KDUT151510
15x15x10mm
4.12
KDUT151010
15x10x10mm
4.57
KDUT151015
15x10x15mm
4.57
KDUT222210
22x22x10mm
4.53
KDUT222215
22x22x15mm
4.53
KDUT221522
22x15x22mm
4.53
KDUT221515
22x15x15mm
4.53
KDUT282822
28x28x22mm
11.57
Size
Pack Qty
Price (each)
KDTC15
15mm
10
2.66
KDTC22
22mm
10
3.41
3. TANK CONNECTORS
Code
Size
Pack Qty
Price (each)
KDSTC15
15mm
10
2.91
KDSTC22
22mm
10
3.45
Size
Pack Qty
Price (each)
15mm
10
3.67
Price (each)
Size
Pack Qty
KDSV15
15mm
7.65
KDSV22
22mm
11.65
Size
Pack Qty
Price (each)
15mm
5.82
Size
Pack Qty
Price (each)
15mm x 3/4"
5.25
9. STOP END
Code
Size
Pack Qty
Price (each)
KDSE15
15mm
10
2.14
KDSE22
22mm
10
2.59
www.davant.co.uk
Davant Whitespeed
Demountable Plastic Plumbing System
Fittings and Accessories
1. 4 PORT MANIFOLD (22mm SOCKET: 10mm PORTS)
Code
KDMAN4
Size
Pack Qty
Price (each)
22mm x 10mm
18.73
Size
Pack Qty
Price (each)
KDLV15B
15mm
10.18
KDLV22B
22mm
23.27
Size
Pack Qty
Price (each)
15mm x 1/2"
10
2.94
KDFAST22B
22mm 3/4"
10
3.83
KDFASH22B
22mm 1/2"
10
7.58
Size
Pack Qty
Price (each)
15mm
10
5.30
5. WALLPLATE ELBOW
Code
KDWE15
Size
Pack Qty
Price (each)
15mm
9.23
Price (each)
Size
Pack Qty
KDFAE15B
15mm x 1/2"
9.23
KDFAE22B
22mm x 3/4"
12.13
Size
Pack Qty
Price (each)
KDMAS15B
15mm x 1/2"
10
4.40
KDMAS22B
22mm x 3/4"
10
5.72
8. 'O' RING
Code
Size
Pack Qty
Price (each)
KPOR10
10mm
50
0.20
KPOR15
15mm
50
0.27
KPOR22
22mm
50
0.27
KPOR28
28mm
50
0.38
9. SPACE WASHER
Code
Size
Pack Qty
Price (each)
KDSW10
10mm
50
0.22
KDSW15
15mm
50
0.22
KDSW22
22mm
50
0.22
KDSW28
28mm
50
0.29
www.davant.co.uk
Davant Whitespeed
Demountable Plastic Plumbing System
Accessories
1. STANDARD PIPE CUTTER
Code
KPCUTTER
Pack Qty
Price (each)
17.38
Size
Pack Qty
Price (each)
0-42mm Pipe
21.40
Size
Pack Qty
Price (each)
0-42mm
74.79
Size
Pack Qty
Price (each)
250ml
12
12.15
5. PIPE INSERT
Code
Size
Pack Qty
Price (each)
KPPI10
10mm
50
0.29
KPPI15
15mm
50
0.29
KPPI22
22mm
50
0.36
KPPI28
28mm
50
0.58
6. DEMOUNTABLE TOOL
Code
Size
Pack Qty
Price (each)
KDDT15
15mm
50
0.75
KDDT22
22mm
50
0.75
7. GRAB RING
Code
Size
Pack Qty
Price (each)
KPGR10
10mm
50
0.20
KPGR15
15mm
50
0.20
KPGR22
22mm
50
0.20
KPGR28
28mm
50
0.38
www.davant.co.uk
Davant Whitespeed
Demountable Plastic Plumbing System
Accessories
1. SYSTEM TEST KIT
Code
KDSTKIT
Pack Qty
Price (each)
448.16
Size
Pack Qty
Price (each)
KDBD15
100
0.25
KDBD22
100
0.25
KDBD28
100
0.34
Size
Pack Qty
Price (each)
KDNC10
100
0.19
KDNC15
100
0.27
KDNC22
100
0.27
KDNC28
100
0.33
Size
Pack Qty
Price (each)
KDSF15
100
0.27
KDSF22
100
0.27
KDSF28
100
0.36
www.davant.co.uk
Davant Whitespeed
Demountable Plastic Plumbing System
Merchandising
WHITESPEED STAND
Product / Size
Qty
STRAIGHT 15mm
120
STRAIGHT 22mm
60
ELBOW 15mm
100
ELBOW 22mm
50
TEE 15mm
80
TEE 22mm
30
80
30
60
30
30
STRAIGHT REDUCER 22 x 15 mm
30
15
15
35
45
1050
450
TOTAL FITTINGS
2310
KDMERCH
Price (each)
2,921.96
www.davant.co.uk
Davant Whitespeed
Demountable Plastic Plumbing System
WHITESPEED is the new, totally flexible plumbing
system from Davant Products, the result of
considerable investment in research and
development, WHITESPEED is tailor made for the
professional plumbing and heating installer who
wants a high quality system that is simple to fit,
durable in use, yet competitively priced.
Comprehensive range
The system offers a comprehensive choice
of pipe and fittings in 10mm, 15mm, 22mm and 28mm
sizes, suitable for all hot and cold plumbing and central
heating systems. It can be used in both sealed and
open vented systems and has been designed to
withstand constant pressure at high temperatures. The
combination of low thermal conductivity and high
corrosion resistance makes it ideal for use in central
heating systems.
www.davant.co.uk
Davant Whitespeed
Demountable Plastic Plumbing System
Product physical properties and guidelines
Advantages and
Physical Properties & Guidelines
Applications
Handling
Storage
Installation Instructions
Connecting to Metric Copper
Connecting to Compression Fittings
Connecting to Heating Appliances
Bending the Pipe
General Precautions
Electric Installations
Rodents
TEMPERATURE
Painting
Cabling
Clipping
Laying in Concrete and Masonry
System Testing
Corrosion Inhibitors
Chlorine
Gases, Fuels and Fuel Oils
PRESSURE
PSI
20C
12 Bar
174
65C
6 Bar
87
82C
3.5 Bar
51
Kg/cm3
ASTM D 1238
ASTM D 1505
ASTM D 638
PF PB pipe
0..5
0.920
175
Kg/cm3
ASTM D 638
400
ASTM D 638
330
Kg/cm3
Kg/cm/cm
JIS K 7113
ASTM D 256
4000
No Break
Melting Point
D Scale
C
Vicat Softening
ASTM D 2240
DSC
JIS K 7206
60
127
119
C
Cm/cm/C
JIS K 7216
ASTM D 696
Kcal/mhr
CC
ASTM C 177
0.33
Properties
Unit
g/10min
G/cm
Tensile Strength
at Yield
Tensile Strength
at Break
Installation Codes and Product Guidelines
Product Guarantees
Technical Helpline
INTRODUCTION
Installation Codes and Product Guidelines
Product Guarantees
Technical Helpline
W HITESPEED PB offers you a complete and flexible plumbing and
heating system manufactured in a BS EN ISO 9002 approved facility.
W HITESPEED PB pipe and fittings are both manufactured from the
same raw material, therefore offering uniform expansion and
contraction, with an extensive range of both pipe and fittings available
in 10, 15, 16, 20, 22, 25 & 28mm.
W HITESPEED PB fittings house an O ring, spacer washer and grab
ring and employ a simple push-fit technique for joining the fitting to the
pipe. It is suitable for both sealed and open vented heating systems.
W ith its low thermal conductivity and high resistance to corrosion,
W HITESPEED PB offers you the ideal product for all domestic water
supplies and central heating applications.
Manufactured to BS 7291 Part 1 and 2 Class S and awarded BSI
Kitemark License No. KM52006 for Thermoplastic hot and cold pipe
and fittings produced in polybutylene.
AFFILIATIONS
The Institute of Plumbing, Scottish & Northern Ireland Plumbing
Employers Federation
CERTIFICATIONS
BS 7291 Part 1 and 2 Class S
BS EN ISO 9002 Registered Company
ADVANTAGES
W HITESPEED PB offers you a quick and simple push-fit installation,
with our "straight" coiled pipes of 50m and 100m eliminating the need
for several joints on continuous runs. The flexible properties of
polybutylene require fewer fittings to complete the job; installation time
can be reduced by as much as 40%. The pipe is much easier to install
than copper due to its flexibility, allowing the installer to cable through
joists and around obstructions with ease, even the fittings can be
rotated under pressure. Blowtorches, solders and tools are no longer
required to make a watertight joint.
The high impact resistance of polybutylene, due to its flexible
properties, means that it is not easily damaged by impact or accidental
crushing, resulting in less wastage.
W HITESPEED PB has higher heat retention than copper, (insulation is
still recommended) resulting in pipes being cooler to the touch.
W HITESPEED PB pipes and fittings have low thermal conductivity
which means that condensation on cold water pipes is greatly reduced
having the added benefit of a higher resistance to the pipes freezing.
Using W HITESPEED PB pipe and fittings as opposed to copper results
in less mechanical noise through the pipework, eliminating the hammer
effect, thus, giving a much quieter operating system.
W HITESPEED PB pipe and fittings have little monetary scrap value
keeping theft from the site of installation to a minimum.
W HITESPEED PB pipe and fittings are completely non-toxic offering
the safest possible system to guard against water contamination.
W HITESPEED PB pipe and fittings are also completely de-mountable
aiding the plumber during installation.
Test Method
Elongation at
Break
Tensile Modulus
Izod Impact
Strength
Shore Hardness
Point
Brittleness Temp
Coefficient Of
Expansion
Thermal
Conductivity
APPLICATIONS
W HITESPEED PB pipe and fittings offer excellent performance for long
term pressure at high temperatures, coupled with its low thermal
conductivity and high resistance to corrosion, making it the ideal product
for central heating systems.
W HITESPEED PB pipe and fittings are also suitable for the installation of
indirect and direct mains fed cold water services, vented and unvented hot
water systems. W HITESPEEDPB barrier pipe is highly recommended for
use in Underfloor Heating Systems making the complete range of
W HITESPEED PB pipe and fittings one of the most versatile products
available to the plumbing installer to date.
W HITESPEED PB pipe and fittings can even be installed into caravans
and boats where flexibility, low weight and resistance to freezing make
them the most versatile products to use.
HANDLING
Care should be taken when handling all polybutylene products especially
pipe, avoid dragging along the ground, rubbing against rough surfaces
like walls and concrete floors which could reduce the wall thickness
of the pipe. W hen feeding pipe through holes in brickwork and walls
always cover the end of the pipe with tape to avoid debris entering
the pipe, this will also help in avoiding damage to the joining surface.
Care should also be taken to avoid crushing the pipe walls during
bending and the wall of the pipe being punctured by sharp objects.
STORAGE
W HITESPEED PB pipe and fittings should always be stored in their
protective wrapper, away from sources of ultra violet light, for example
direct sunlight. W here installation is unavoidable in areas of direct
sunlight and sources of artificial ultra violet light always install the
pipework into ducting. W hen storage of pipe is required for any length of
time do not exceed 1.5metre stack heights for coils and 1 metre stack
heights for straight lengths.
PAINTING
W HITESPEED PB pipe and fittings can be painted using normal
household paints; however solvent based products and cellulose paints
should not be used. Surfaces to be painted should be free from all
deposits of silicone and grease compounds.
W hen required, re-painting may be achieved by gently rubbing down
with wet and dry using a grade no coarser than 400, hot air guns and
chemical based paint strippers should never be used on any polybutylene
products.
CABLING
W HITESPEED PB pipes flexibility enables the installer to thread the pipe
through concealed and inaccessible spaces with minimal or no disruption
to the surrounding building resulting in major savings to installation time.
The flexibility of W HITESPEED PB pipe means that pipework can be
threaded through dry wall systems, studded partitions and cabled through
holes drilled into joists. There are restrictions as to where joists can be
drilled and notched, these restrictions can be found in the Building
Regulations Approved Document A and BS 6700: 1997.
10
www.davant.co.uk
Davant Whitespeed
Demountable Plastic Plumbing System
As a general guide:
Holes in roof and floor joists should be no greater than 0.25 times
the overall depth.
Holes drilled into the joist should be drilled at the neutral axis and
should not be less than 3 diameters (centre to centre) apart.
Holes should be spaced between 0.25 and 0.4 times the span from
the support.
Notches in roof and floor joists should be no deeper than 0.125
times the depth of the joist.
Notches in roof and floor joists should under no circumstance be
cut any closer to the support than 0.07 of the span and no further
away than 0.25 times the span.
Installation Instructions
CONNECTING TO METRIC SIZE COPPER
W HITESPEED PB fittings are suitable for use with all metric sized
copper tube manufactured to BS2871.
The copper tube should be cut using a plumber's pipe cutter, remove all
sharp edges to avoid damaging the O-ring when inserting into the
W HITESPEED PB fitting.
CONNECTING TO METRIC SIZE COMPRESSION FITTINGS
W HITESPEED PB pipe can be used with compression fittings
manufactured to BS864. A W HITESPEED stainless steel insert must
always be inserted into the W HITESPEED PB pipe before compressing
the joint. The olive must be within the length of the support sleeve and
PTFE tape over the olive will ensure a watertight seal is achieved.
CONNECTING TO A HEATING APPLIANCE
W hen connecting to any heating appliance you must ensure that at
least 2 metres of copper pipe is firstly connected to the heating
appliance on both the flow out and the return before connecting to
W HITESPEED PB pipe. Care should be taken to ensure that the
heating appliance has the appropriate thermostatic cut out controls to
ensure that operating temperatures do not exceed the pressure and
temperature limits for Class S thermoplastic pipe.
BENDING THE PIPE
W HITESPEED PB pipe's immense flexibility enables the installer, by
clipping the pipe into place, to cold form bends up to 8 times the pipes
diameter, in many cases dispensing with the need to make elbow
connections, again reducing installation time.
CLIPPING
W HITESPEED PB pipe as with all polybutylene pipe is not self
supporting like copper, it is therefore recommended that polybutylene
pipe be supported as set out in BS5955: Part 8:1990.
RECOMMENDED CLIPPING DISTANCES
Installation Instructions
LAYING INTO CONCRETE AND MASONRY
GPF PB pipe and fittings can be laid into concrete and masonry
provided that they are installed into conduit pipe and junction
boxes.
This is to ensure that access to the pipe and fittings can take place
should the need arise to carry out any maintenance.
Insulation is also recommended to protect against frost and heat
loss.
Please check recommendations as outlined in Byelaw 58.
SYSTEM TESTING
A full scale systems check should be carried out in accordance with
BS6700: 1997 and Water Supply Regulations 1999.
When the installation is complete the system should be filled and
flushed out, refill the system slowly to avoid any air locks.
WHITESPEED PB blanking caps and stop ends are particularly
useful to plug all outlets prior to system testing taking place.
We recommend that the system be subjected to a hydraulic
pressure
test for 30 minutes at 10-bar minimum then reducing to 5-bar for a
further 30 minutes. When testing be sure that pressures used do
not
exceed manufacturer's levels for boilers, cylinders and pumps.
Any drop off in pressure over this period should be investigated and
any leakages within the system must be repaired or replaced.
CORROSION INHIBITORS
It is recommended that a corrosion inhibitor be used at all times.
W HITESPEED PB pipe and fittings are in no way affected by the anticorrosion properties found in compounds such as Sentinel and Fernox.
All heating circuits should be protected by an appropriate inhibitor
as oxygen may enter the system through a variety of points such
as pumps, header tanks and valves.
W HITESPEED PB barrier pipe has the added advantage of an oxygen
barrier incorporated into the pipe to greatly reduce the ingress
of oxygen through the pipe wall.
It is therefore highly recommended that barrier pipe be used
along with an inhibitor on all sealed heating systems.
General Precautions
ELECTRICAL INSTALLATIONS
W HITESPEED PB pipe as with all plastic products is non-conductive
and
should not be used to provide an earth return.
W here W HITESPEED PB pipe is used to replace a section of existing
copper pipe that was previously earthed, electrical continuity should be
reinstated by affixing a section of earth cable between the ends of the
copper pipe secured to the metal using clamps or clips. No
requirements are however needed to bond the pipe work to earth on
new installations where no metal pipe is installed.
However all electrical requirements for heaters, cylinders and pumps
etc. should be taken into account. If in any doubt consult a qualified
electrician.
RODENTS
In this day and age it is highly unlikely for properties to be infested with
rodents. However, if rodents are present in large numbers and no steps
towards extermination have been carried out, it is possible that damage
to electrical and plumbing materials, including W HITESPEED PB, could
occur.
CHLORINE
The W HITESPEED PB range of pipe and fittings are suitable for
carrying normal levels of chlorine found in domestic water supply
systems.
It is however not suitable for carrying large quantities, for example, water
circulation of swimming pools that use large concentrations of chlorine.
Short-term exposure of chlorine used for disinfecting will have no
adverse effect on the system provided the maximum permitted level of
5ppm is not exceeded.
GASES, FUEL AND FUEL OILS
W HITESPEED PB pipe and fittings are not suitable for the transportation
of gases, steam and compressed air; it is also not suitable for the
transportation of fuel oils including petroleum.
INSTALLATION CODES AND PRODUCT GUIDELINES
The guides and standards below should be followed during design and
installation when using W HITESPEED PB pipe and fittings.
BS 6700:1997. Specification for design, installation, testing and
maintenance of services supplying water for domestic use within
buildings and their curtilages.
W SR:1999. W ater Supply Regulations 1999.
W IA:1991. W ater Industry Act 1991.
BS 5955 Part 8:1990. Specification for the installation of thermoplastic
pipe and fittings for use in domestic hot and cold water services, and
heating systems.
BS8000. W orkmanship on building sites Part 15: 1990 code of
practice for hot and cold water services.
BS 5499: 1990. Specification for forced circulation hot water
central heating systems for domestic premises.
The Institute of Plumbing's. - Plumbing Engineering Services
Design Guide.
Guide to the use of plastic pipework. TR11, HVCA, 1992.
Mechanical and electrical standard specification for heating, hot
and cold water installations for dwellings.
Published by the former PSA.
PRODUCT GUARANTEE
25 Year Product Guarantee.
W HITESPEED PB pipe and fittings are guaranteed for 25 years against
defects in materials or manufacture from date of purchase.
This guarantee only applies if the system is installed to the
recommendations within this Technical and Installation guide, and is
used in a normal domestic operation.
TECHNICAL HELPLINE
For further information please contact our Technical Helpline on:
Tel. 01531 630068
Fax. 01531 636638
Email: info@davant.co.uk
11
www.davant.co.uk
Size
Pack Qty
Price (each)
KPBC10/100
158.35
KPBC10/50
80.00
KPBC10/25
40.47
KPBC15/100
182.80
KPBC15/50
90.44
KPBC15/30
55.54
KPBC15/25
46.28
KPBC15/15
27.76
KPBC22/50
179.24
KPBC22/30
108.38
KPBC22/25
90.30
KPBC22/15
54.19
Size
Pack Qty
Price (each)
KPBL15/5
20
11.12
KPBL15/3
15mm x 3m Lengths
20
5.57
KPBL22/5
10
21.77
KPBL22/3
22mm x 3m Lengths
10
10.88
KPBL28/5
29.50
KPBL28/3
28mm x 3m Lengths
14.80
3. STANDARD PIPE
Size
Pack Qty
Price (each)
KPC10/100
137.53
KPC10/50
70.51
KPC10/25
35.69
KPC15/100
159.30
KPC15/50
80.00
KPC15/25
40.92
KPC22/50
156.60
KPC22/25
78.95
KPL15/5
20
9.56
KPL15/3
15mm x 3m Coils
20
4.86
KPL22/5
10
19.13
KPL22/3
22mm x 3m Coils
10
9.57
KPL28/5
26.03
KPL28/3
28mm x 3m Coils
13.03
Code
4. STRAIGHT COUPLER
Size
Pack Qty
Price (each)
KPSC10
10mm
10
3.12
KPSC15
15mm
10
2.01
KPSC22
22mm
2.60
KPSC28
28mm
6.80
Code
12
www.davant.co.uk
Pack Qty
Price (each)
KPSR1510
15mm x 10mm
10
3.04
KPSR2215
22mm x 15mm
10
2.41
Size
Pack Qty
Price (each)
KPSKR1510
15mm x 10mm
10
2.79
KPSKR2215
22mm x 15mm
10
2.39
KPSKR2822
28mm x 22mm
10
5.47
Code
2. SOCKET REDUCER
Code
3. ELBOW
Size
Pack Qty
Price (each)
KPE10
10mm
10
3.46
KPE15
15mm
10
2.44
KPE22
22mm
10
3.46
KPE28
28mm
8.18
Code
4. TEE
Size
Pack Qty
Price (each)
KPT10
10mm
10
4.45
KPT15
15mm
10
3.46
KPT22
22mm
10
4.45
KPT28
28mm
11.28
Code
5. UNEQUAL TEE
Size
Pack Qty
Price (each)
KPUT151510
15 x 15 x 10mm
4.45
KPUT151010
15 x 10 x 10mm
4.45
KPUT151015
15 x 10 x 15mm
4.45
KPUT222210
22 x 22 x 10mm
4.45
KPUT222215
22 x 22 x 15mm
4.45
KPUT221522
22 x 15 x 22mm
4.45
KPUT221515
22 x 15 x 15mm
4.45
KPUT282822
28 x 28 x 22mm
12.45
Price (each)
Code
6. TANK CONNECTOR
Code
KPTC15
15mm
10
2.59
KPTC22
22mm
10
3.23
Pack Qty
Price (each)
KPSTC15
15mm
10
2.60
KPSTC22
22mm
10
3.23
Size
Pack Qty
Price (each)
15mm
10
3.46
Code
13
www.davant.co.uk
Pack Qty
Price (each)
KPSV15
15mm
7.76
KPSV22
22mm
9.29
Size
Pack Qty
Price (each)
5.17
Code
2. ISOLATING VALVE
Code
KPIV15
3. APPLIANCE VALVE
Size
Pack Qty
Price (each)
KPWM15B
5.07
KPWM15R
5.07
Size
Pack Qty
Price (each)
KPLV15B
15mm
5.21
KPLV22B
22mm
9.38
Size
Pack Qty
Price (each)
15mm
5.57
Size
Pack Qty
Price (each)
KPFAE15B
15mm x 1/2"
8.45
KPFAE22B
22mm x 3/4"
7.96
Code
5. WALLPLATE ELBOW
Code
KPWE15
Pack Qty
Price (each)
KPMAS10B
10mm x 3/8"
10
4.71
KPMAS15B
15mm x 1/2"
10
4.53
KPMAS22B
22mm x 3/4"
10
6.71
Code
Pack Qty
Price (each)
KPFAS10B
10mm x 3/8"
10
4.71
KPFAS15B
15mm x 1/2"
10
4.53
KPFAST22B
22mm x 3/4"
10
6.71
KPFASH22B
22mm x 1/2"
10
7.96
Code
Size
Pack Qty
Price (each)
15mm
3.46
Pack Qty
Price (each)
KPSE15
15mm
10
2.15
KPSE22
22mm
10
2.71
Code
14
www.davant.co.uk
Pack Qty
Price (each)
22mm x 10mm
12.11
Code
KPMAN4
2. 'O' RING
Size
Pack Qty
Price (each)
KPOR10
10mm
50
0.20
KPOR15
15mm
50
0.27
KPOR22
22mm
50
0.27
KPOR28
28mm
50
0.38
Code
3. SPACE WASHERS
Size
Pack Qty
Price (each)
KPSW10
10mm
50
0.22
KPSW15
15mm
50
0.22
KPSW22
22mm
50
0.22
KPSW28
28mm
50
0.29
Size
Pack Qty
Price (each)
17.39
Size
Pack Qty
Price (each)
0-42mm Pipe
21.40
Code
Pack Qty
Price (each)
250ml
12
12.15
Size
Pack Qty
Price (each)
0-42mm
74.79
Code
KPLUBS
7. KTS PIPE CUTTER KIT
Code
KPKTS180
Pack Qty
Price (each)
KPBD15
100
0.12
KPBD22
100
0.18
KPBD28
100
0.25
Code
Pack Qty
Price (each)
KPNC10
100
0.15
KPNC15
100
0.25
KPNC22
100
0.25
KPNC28
100
0.29
Code
15
www.davant.co.uk
Pack Qty
Price (each)
KPSF15
100
0.25
KPSF22
100
0.25
KPSF28
50
0.38
Size
Pack Qty
Price (each)
KPPI10
10mm
50
0.33
KPPI15
15mm
50
0.33
KPPI22
22mm
50
0.40
KPPI28
28mm
50
0.66
Size
Pack Qty
Price (each)
KPB10
10mm
50
0.29
KPB15
15mm
50
0.39
KPB22
22mm
50
0.41
Code
2. PIPE INSERTS
Code
3. BLANKS
Code
4. GRAB RINGS
Size
Pack Qty
Price (each)
KPGR10
10mm
50
0.20
KPGR15
15mm
50
0.20
KPGR22
22mm
50
0.20
KPGR28
28mm
50
0.38
Code
16
www.davant.co.uk
Qty
STRAIGHT 15mm
120
STRAIGHT 22mm
100
ELBOW 22mm
50
TEE 15mm
80
TEE 22mm
30
80
30
60
30
30
STRAIGHT REDUCER 22 x 15 mm
30
15
15
35
45
1050
450
TOTAL FITTINGS
KDMERCH
60
ELBOW 15mm
17
Price (each)
2310
1
2,993.33
www.davant.co.uk
Comprehensive range
Ensure all cap nuts are hand
tightened. Visually check the
internal
components. Make the correct
insertion depth by observing the
chevron markings on the pipe. Push
the pipe firmly and horizontally into
the fitting. A secure joint has been
made when the correct insertion
marking is reached.
18
www.davant.co.uk
Advantages and
Physical Properties & Guidelines
Applications
Handling
Storage
Painting
Cabling
Installation Instructions
Connecting to Metric Copper
Connecting to Compression Fittings
Connecting to Heating Appliances
Bending the Pipe
General Precautions
Electric Installations
Rodents
Clipping
Laying in Concrete and Masonry
System Testing
Corrosion Inhibitors
Chlorine
Gases, Fuels and Fuel Oils
APPLICATIONS
GPF PB pipe and fittings offer excellent performance for long term
pressure at high temperatures, coupled with its low thermal
conductivity
and high resistance to corrosion, making it the ideal product for central
heating systems.
GPF PB pipe and fittings are also suitable for the installation of indirect
and direct mains fed cold water services, vented and unvented hot
water systems. GPF PB barrier pipe is highly recommended for use
in Underfloor Heating Systems making the complete range of GPF
PB pipe and fittings one of the most versatile products available to
the plumbing installer to date.
GPF PB pipe and fittings can even be installed into caravans and
boats where flexibility, low weight and resistance to freezing make
them the most versatile products to use.
HANDLING
Care should be taken when handling all polybutylene products
especially
pipe, avoid dragging along the ground, rubbing against rough surfaces
like walls and concrete floors which could reduce the wall thickness
of the pipe. W hen feeding pipe through holes in brickwork and walls
always cover the end of the pipe with tape to avoid debris entering
the pipe, this will also help in avoiding damage to the joining surface.
Care should also be taken to avoid crushing the pipe walls during
bending and the wall of the pipe being punctured by sharp objects.
STORAGE
GPF PB pipe and fittings should always be stored in their protective
wrapper, away from sources of ultra violet light, for example direct
sunlight. W here installation is unavoidable in areas of direct sunlight
and sources of artificial ultra violet light always install the pipework
into ducting. W hen storage of pipe is required for any length of time
do not exceed 1.5metre stack heights for coils and 1 metre stack
heights for straight lengths.
PAINTING
GPF PB pipe and fittings can be painted using normal household
paints; however solvent based products and cellulose paints should
not be used. Surfaces to be painted should be free from all deposits
of silicone and grease compounds.
W hen required, re-painting may be achieved by gently rubbing down
with wet and dry using a grade no coarser than 400, hot air guns and
chemical based paint strippers should never be used on any
polybutylene
products.
CABLING
GPF PB pipes flexibility enables the installer to thread the pipe through
concealed and inaccessible spaces with minimal or no disruption to the
surrounding building resulting in major savings to installation time. The
flexibility of GPF PB pipe means that pipework can be threaded
through
dry wall systems, studded partitions and cabled through holes drilled
into joists. There are restrictions as to where joists can be drilled and
notched, these restrictions can be found in the Building Regulations
Approved Document A and BS 6700: 1997.
19
www.davant.co.uk
CORROSION INHIBITORS
It is recommended that a corrosion inhibitor be used at all times.
GPF PB pipe and fittings are in no way affected by the anticorrosion properties found in compounds such as Sentinel and
Fernox.
All heating circuits should be protected by an appropriate inhibitor
as oxygen may enter the system through a variety of points such
as pumps, header tanks and valves.
GPF PB barrier pipe has the added advantage of an oxygen
barrier incorporated into the pipe to greatly reduce the ingress
of oxygen through the pipe wall.
It is therefore highly recommended that barrier pipe be used
along with an inhibitor on all sealed heating systems.
General Precautions
ELECTRICAL INSTALLATIONS
GPF PB pipe as with all plastic products is non-conductive and
should not be used to provide an earth return.
W here GPF PB pipe is used to replace a section of existing
copper pipe that was previously earthed, electrical continuity
should be reinstated by affixing a section of earth cable between
the ends of the copper pipe secured to the metal using clamps
or clips. No requirements are however needed to bond the pipe
work to earth on new installations where no metal pipe is installed.
However all electrical requirements for heaters,
cylinders and pumps etc. should be taken into account. If in any
doubt consult a qualified electrician.
RODENTS
In this day and age it is highly unlikely for properties to be infested
with rodents. However, if rodents are present in large numbers
and no steps towards extermination have been carried out, it is
possible that damage to electrical and plumbing materials,
including
GPF PB, could occur.
CHLORINE
The GPF PB range of pipe and fittings are suitable for carrying
normal levels of chlorine found in domestic water supply systems.
It is however not suitable for carrying large quantities, for example,
water circulation of swimming pools that use large concentrations
of chlorine. Short-term exposure of chlorine used for disinfecting
will have no adverse effect on the system provided the maximum
permitted level of 5ppm is not exceeded.
GASES, FUEL AND FUEL OILS
GPF PB pipe and fittings are not suitable for the transportation
of gases, steam and compressed air; it is also not suitable for the
transportation of fuel oils including petroleum.
INSTALLATION CODES AND PRODUCT GUIDELINES
The guides and standards below should be followed during design
and installation when using GPF PB pipe and fittings.
BS 6700:1997. Specification for design, installation, testing and
maintenance of services supplying water for domestic use within
buildings and their curtilages.
W SR:1999. W ater Supply Regulations 1999.
W IA:1991. W ater Industry Act 1991.
BS 5955 Part 8:1990. Specification for the installation of
thermoplastic pipe and fittings for use in domestic hot and cold
water services, and heating systems.
BS8000. W orkmanship on building sites Part 15: 1990 code of
practice for hot and cold water services.
BS 5499: 1990. Specification for forced circulation hot water
central heating systems for domestic premises.
The Institute of Plumbing's. - Plumbing Engineering Services
Design Guide.
Guide to the use of plastic pipework. TR11, HVCA, 1992.
Mechanical and electrical standard specification for heating, hot
and cold water installations for dwellings.
Published by the former PSA.
Installation Instructions
CONNECTING TO METRIC SIZE COPPER
GPF PB fittings are suitable for use with all metric sized copper tube
manufactured to BS2871.
The copper tube should be cut using a plumber's pipe cutter, remove all
sharp edges to avoid damaging the O-ring when inserting into theGPF
PB fitting.
CONNECTING TO METRIC SIZE COMPRESSION FITTINGS
GPF PB pipe can be used with compression fittings manufactured to
BS864. A GPF stainless steel insert must always be inserted into
the GPF PB pipe before compressing the joint. The olive must be
within the length of the support sleeve and PTFE tape over the olive
will ensure a watertight seal is achieved.
CONNECTING TO A HEATING APPLIANCE
W hen connecting to any heating appliance you must ensure that at
least 2 metres of copper pipe is firstly connected to the heating
appliance on both the flow out and the return before connecting to
GPF PB pipe. Care should be taken to ensure that the heating
appliance has the appropriate thermostatic cut out controls to ensure
that operating temperatures do not exceed the pressure and
temperature limits for Class S thermoplastic pipe.
BENDING THE PIPE
PF PB pipe's immense flexibility enables the installer, by clipping
the pipe into place, to cold form bends up to 8 times the pipes diameter,
in many cases dispensing with the need to make elbow connections,
again reducing installation time.
CLIPPING
GPF PB pipe as with all polybutylene pipe is not self supporting like
copper, it is therefore recommended that polybutylene pipe be
supported
as set out in BS5955: Part 8:1990.
RECOMMENDED CLIPPING DISTANCES
Installation Instructions
LAYING INTO CONCRETE AND MASONRY
GPF PB pipe and fittings can be laid into concrete and masonry
provided that they are installed into conduit pipe and junction
boxes.
This is to ensure that access to the pipe and fittings can take place
should the need arise to carry out any maintenance.
Insulation is also recommended to protect against frost and heat loss.
Please check recommendations as outlined in Byelaw 58.
SYSTEM TESTING
A full scale systems check should be carried out in accordance with
BS6700: 1997 and W ater Supply Regulations 1999.
W hen the installation is complete the system should be filled and
flushed out, refill the system slowly to avoid any air locks.
GPF PB blanking caps and stop ends are particularly useful to plug
all outlets prior to system testing taking place.
W e recommend that the system be subjected to a hydraulic pressure
test for 30 minutes at 10-bar minimum then reducing to 5-bar for a
further 30 minutes. W hen testing be sure that pressures used do not
exceed manufacturer's levels for boilers, cylinders and pumps.
Any drop off in pressure over this period should be investigated and
any leakages within the system must be repaired or replaced.
PRODUCT GUARANTEE
25 Year Product Guarantee.
GPF PB pipe and fittings are guaranteed for 25 years against
defects in materials or manufacture from date of purchase.
This guarantee only applies if the system is installed to the
recommendations within this Technical and Installation guide, and
is used in a normal domestic operation.
TECHNICAL HELPLINE
For further information please contact our Technical Helpline on:
Tel. 01531 630068
Fax. 01531 636638
Email: info@davant.co.uk
20
www.davant.co.uk
Davant Interlock
Demountable Plastic Plumbing System
1. BARRIER PIPE - COILS (Available in White)
Code
Size
Pack Qty
(each)
KDBC10/100
148.04
KDBC10/50
74.02
KDBC10/25
37.01
KDBC15/150
256.22
KDBC15/100
170.81
KDGBC15/50
85.41
KDGBC15/30
51.24
KDGBC15/25
42.71
KDGBC15/15
25.63
KDBC22/50
162.45
KDGBC22/30
97.47
KDGBC22/25
81.23
KDGBC22/15
48.74
Size
Pack Qty
() each
KDBL15/5
20
10.24
KDBL15/3
15mm x 3m Lengths
20
5.12
KDBL22/5
10
19.49
KDBL22/3
22mm x 3m Lengths
10
9.75
KDBL28/5
29.45
KDBL28/3
28mm x 3m Lengths
14.73
3. STRAIGHT COUPLER
Code
Size
Pack (10)
() each
KISC10
10mm
19.31
1.93
KISC15
15mm
14.36
1.44
KISC22
22mm
22.48
2.25
4. STRAIGHT REDUCER
Code
Size
Pack (10)
() each
KISR1510
15mm x 10mm
33.67
3.37
KISR2215
22mm x 15mm
39.55
3.96
5. ELBOW
Code
Size
Pack (10)
() each
10mm
23.66
2.37
KIE15
15mm
16.95
1.70
KIE22
22mm
26.96
2.70
KIE10
6. STEM ELBOW
Code
Size
Pack (10)
() each
KISTEM10
10mm
29.43
2.94
KISTEM15
15mm
33.20
3.32
21
www.davant.co.uk
Davant Interlock
Demountable Plastic Plumbing System
1. TEE
Code
Size
Pack (10)
() each
KIT10
10mm
27.31
2.73
KIT15
15mm
24.49
2.45
KIT22
22mm
36.38
3.64
2. UNEQUAL TEE
Code
Size
Pack (10)
() each
KIUT151010
15 x 10 x 10mm
41.08
4.11
KIUT151510
15 x 15 x 10mm
36.96
3.70
KIUT151522
15 x 15 x 22mm
41.08
4.11
KIUT221515
22 x 15 x 15mm
41.08
4.11
KIUT222210
22 x 22 x 10mm
41.08
4.11
KIUT222215
22 x 22 x 15mm
41.08
4.11
3. STOP END
Code
Size
Pack (10)
() each
KISE10
10mm
18.72
1.87
KISE15
15mm
19.31
1.93
KISE22
22mm
23.31
2.33
Size
Pack (10)
() each
15mm
35.32
3.53
Size
Pack (10)
() each
KISTC15
15 x 1/2"
28.02
2.80
KISTC1522
15 x 3/4"
33.20
3.32
KISTC22
22 x 3/4"
36.49
3.65
6. SOCKET REDUCER
Code
Size
Pack (10)
() each
KISKR1510
15 x 10mm
16.48
1.65
KISKR2215
22 x 15mm
21.43
2.14
22
www.davant.co.uk
Davant Interlock
Demountable Plastic Plumbing System
1. COLLET CLIP BLUE
Code
Size
Pack (50)
() each
KICB10
10mm
4.94
0.10
KICB15
15mm
4.94
0.10
KICB22
22mm
5.57
0.11
Size
Pack (50)
() each
KICR10
10mm
4.94
0.10
KICR15
15mm
4.94
0.10
KICR22
22mm
5.57
0.11
Size
Pack (50)
() each
KICW10
10mm
4.94
0.10
KICW15
15mm
4.94
0.10
KICW22
22mm
5.57
0.11
4. PIPE INSERTS
Code
Size
Pack (50)
() each
KPPI10
10mm
13.60
0.27
KPPI15
15mm
13.60
0.27
22mm
16.69
0.33
KPPI22
TECHNICAL NOTES
Davant Interlock hot and cold water systems. The principles
adapted within this system are based upon the general
requirements of BS7291 and the byelaws detailed within the
Water Regulations Advisory Service (WRAS) and manufactured
under ISO conditions.
For Interlock to be sold with the UK and European market.
Extensive testing has been undertaken to prove both the
materials and products are manufactured in a controlled
environment from approved materials. As a result the range holds
WRAS accreditation.
Features
Fully demountable system
Easygrip oval collet for rapid dismount
All white, lightweight system
Easy to use and handle
Slim line fitting for exposed application
Safe and solid connection
Benefits
No soldering required
Non Toxic
Safer surface temperature
Less noise during expansion and contraction
Fewer fittings required
Flexibility in difficult areas
Reduction in installation time
Corrosion Free
No scale build-up
High resistance to impact
Low wastage
Interlock is compliant with any BS Standard pipe (copper or
plastic)
23
www.davant.co.uk
Davant Interlock
TECHNICAL NOTES
SYSTEM TYPE
Cold water
Open vented CH system
Sealed CH system
1.
2.
3.
4.
Do's
Use purpose designed cutters when cutting pipe.
Cut the pipe at the Chevron marks to ensure correct insertion.
When cutting the pipe whilst maintaining the pressure until the
pipe is severed.
Cut the pipe squarely.
Ensure pipe is clean, free from burrs & surface damage.
The correct pipe insert is used.
Push the pipe and fittings together firmly.
When dismantling the connection, hold the puller first and then
the pipe. Do not pull the pipe first.
24
www.davant.co.uk
Price
BM4R
4.36
BM4RL
3.73
Price
BM15R
18.84
BM15RL
9.59
Price
BM20R
21.98
BM20RL
11.08
Price
BM25R
25.49
BM25RL
12.27
Price
BM40R
46.24
BM40RL
19.89
Code
Price
BM50R
47.38
BM50RL
21.13
25
www.davant.co.uk
Price
B25C
22.06
B25CL
11.82
Price
B50C
36.43
B50CL
18.06
Price
B100C
88.27
B100CL
33.82
Price
B25X
69.83
B25XL
0.00
Price
B50X
114.31
B50XL
0.00
Price
B100X
146.87
B100XL
0.00
26
www.davant.co.uk
Price
B241717T
31.80
B241717L
9.54
Price
B241220T
51.20
B241220L
11.55
Price
B272020T
31.07
B272020L
9.54
Code
B202020T
n/a
B202020L
n/a
Price
B4RJ
2.99
B15RJ
5.19
B20RJ
6.38
B25RJ
6.80
B40RJ
10.55
B50RJ
10.81
2. CIRCULAR JACKETS
Price
Code
B25CJ
6.76
B50CJ
9.55
B100CJ
19.39
Code
Price
B25XJ
13.51
B50XJ
21.77
B100XJ
28.14
27
www.davant.co.uk
Price
B4RA
8.99
B4RB
8.99
B15RA
24.30
B15RB
27.90
B20RA
27.12
B20RB
30.80
B25RA
28.75
B25RB
32.35
B40RA
40.92
B40RB
44.52
B50RA
42.94
B50RB
46.53
Price
B25CA
28.55
B25CB
32.20
B50CA
40.35
B50CB
44.00
B100CA
76.36
B100CB
80.00
Price
B25XA
17.38
B25XB
21.01
B50XA
25.64
B50XB
29.24
B100XA
32.02
B100XB
35.63
Code
Price
B241717XA
25.42
B241717XB
29.07
B241220XA
26.29
B241220XB
29.96
B272020XA
25.89
B272020XB
29.50
B202020XA
n/a
B202020XB
n/a
28
www.davant.co.uk
Code
EK201
4.90
BAKITB
15.13
2. BALLVALVE PACK
Price
Code
BB4RPACK
6.10
BBPACK
8.71
Code
BAPLATEL
0.41
Price
BM4RTK(30)
15.09
BM15RTK(30)
33.03
BM20RTK(30)
35.83
BM25RTK(30)
37.46
BM40RTK(30)
49.64
BM50RTK(30)
51.66
Price
B25CTK(30)
37.26
B50CTK(30)
49.07
B100CTK(30)
85.08
Price
B25XTK(30)
26.10
B50XTK(30)
34.35
B100XTK(30)
40.73
Code
Price
B241717TTK(30)
34.13
B241220TTK(30)
35.01
B272020TTK(30)
34.61
B202020TTK(30)
n/a
29
www.davant.co.uk
Price
BM4RTK(60)
15.09
BM15RTK(60)
36.61
BM20RTK(60)
39.51
BM25RTK(60)
41.06
BM40RTK(60)
53.23
BM50RTK(60)
55.26
Price
B25CTK(60)
40.91
B50CTK(60)
52.72
B100CTK(60)
88.71
Price
B25XTK(60)
29.75
B50XTK(60)
37.95
B100XTK(60)
44.35
Code
Price
B241717TTK(60)
37.78
B241220TTK(60)
38.67
B272020TTK(60)
38.22
B202020TTK(60)
n/a
30
www.davant.co.uk
INSTALLATION INSTRUCTIONS
31
www.davant.co.uk
Gallons
Actual
4
15
20
25
40
50
Gallons
Nominal
10
25
30
40
60
70
Length (mm)
442
600
665
736
940
1150
Length (ins)
17
24
26
29
37
45
Width (mm)
296
425
490
584
610
635
2. CIRCULAR TANKS
Litres
Code
Actual
B25C (flexible) 114
B50C (flexible) 227
B100C
455
Litres
Nominal
182
315
682
Gallons
Actual
25
50
100
Gallons
Nominal Upper (mm) Upper (ins) Lower (mm) Lower (ins) Height (mm) Height ins
40
686
27
580
23
533 21
70
838
33
748
30
610 24
150
1041
41
938
37
787 31
3. LOFT TANKS
Litres
Code
Actual
B25X
114
B50X
227
B100X
455
Litres
Nominal
182
315
682
Gallons
Actual
25
50
100
Gallons
Nominal
40
70
150
Length (mm)
1120
1420
1790
Length (ins)
45
56
71
Gallons
9
15
20
Length (mm)
635
610
508
Length (ins)
25
24
20
32
www.davant.co.uk
This pack contains all the required components to meet Water Regulations.
By fitting all of those components to the correct cistern as detailed below you will meet requirements of the Water Regulations.
Tank Pack contains:
1. Lid
2. Insulation Jacket
3. Either Byelaw 30 or 60 kit
4. Ballvalve kit
5. Galvanised Ballvalve backingplate
The above should be fixed onto the cistern and cover in your required positions. An example is illustrated. The ball valve inlet and tank
connector outlet are at opposite ends of the cistern to create a flow of water inside the cistern to avoid stagnation. It is essential that the outer
extremities of the pipe connection washer are clear of the cistern corner radii. Support each hole when cutting. Do not use hot copper pipes
to burn holes.
The cistern must be installed as per the instructions on the cistern label. It must be stressed that no paste, putty or sealing compound is to be
used in the installation of plastic cisterns or components. If joints need to be sealed, PTFE tape should be used. When assembling the
insulation jacket - you must not cover the breather filter with the jacket.
All installations should be in accordance with BS6700. If you have any doubts or queries re the installation, you should contact your local
water company.
33
www.davant.co.uk
Contents
DAVANT 30 KIT A
EK201
Expansion Pipe Grommet, Screened Breather screened overflow with dip tube.
50
DAVANT 60 KIT B
BAKITB
Expansion Pipe Grommet, Screened Breather1 screened Overflow with dip tube.
50
2. BALLVALVE PACK
Code
Contents
BB4RPACK
1 x BS 1212 High Pressure Part 2 Ballvalve suitable for potable water up to 300PSI incoming
water pressure. Diaphragm operated valve - Brass body 1/8 Acetyl seat fitted as standard,
1 x 4.5 Poly Float c/w brass insert.
Code
Singles
BBPACK
1 x BS 1212 High Pressure Part 2 Ballvalve suitable for potable water up to 300PSI incoming
water pressure. Diaphragm operated valve - Brass body 1/8 Acetyl seat fitted as standard,
1 x 4.5 Poly Float c/w brass insert, 1 x 22mm Straight Tank Connector Brass*,
1 x 15mm Angle Service Valve - c/w red fibre washer*
Singles
Description
Singles
34
www.davant.co.uk
Monday
Tuesday
Wednesday
Thursday
Friday
North London:
North London:
Acton, Amersham, Aylesbury, Barking, Basildon, Beaconsfield, Bicester, Braintree, Buckingham, Chadwell Heath, Chelmsford,
Cheltenham, Chingford, Clacton on Sea, Colchester, Cricklewood (London NW2), Dagenham, Enfield, Edgware, Essex, Forest
Gate (London), Gloucester, Greenford, Hadleigh, Harlow, Harpenden, Hemel Hempstead, High Wycombe, Hitchin, Hoddesdon,
Hornchurch, Ilford, Kidlington, Kings Cross (CARRIER WHERE POSS), Leyton (London), Luton, Maldon, Manningtree (Essex),
Northolt, Oxford, Potters Bar, Rainham, Rayleigh, Romford, Ruislip, Southall, Southend on Sea, South Oxhey, St Albans,
Stanmore, Stevenage, Thame, Tottenham, Upminster, Watford, Welwyn Garden City (WGC), Wembley, Wickford, Witham,
Witney
Acton, Amersham, Aylesbury, Barking, Basildon, Beaconsfield, Bicester, Braintree, Buckingham, Chadwell
Heath, Chelmsford, Cheltenham, Chingford, Clacton on Sea, Colchester, Cricklewood (London NW2),
Dagenham, Enfield, Edgware, Essex, Forest Gate (London), Gloucester, Greenford, Hadleigh, Harlow,
Harpenden, Hemel Hempstead, High Wycombe, Hitchin, Hoddesdon, Hornchurch, Ilford, Kidlington, Kings Cross
(CARRIER WHERE POSS), Leyton (London), Luton, Maldon, Manningtree (Essex), Northolt, Oxford, Potters Bar,
Rainham, Rayleigh, Romford, Ruislip, Southall, Southend on Sea, South Oxhey, St Albans, Stanmore,
Stevenage, Thame, Tottenham, Upminster, Watford, Welwyn Garden City (WGC), Wembley, Wickford, Witham,
Witney
South London:
East Anglia:
South London:
Abbotsfield, Aldershot, Ashford, Arlington, Aylesford, Banstead, Basingstoke, Battersea, Beckenham, Belvedere,
Bracknell, Brighton, Burgess Hill, Camberley, Canterbury, Carshalton, Chatham, Cheltenham (Th/F RUN ONLY)
Chertsey, Chessington, Chichester, Crayford, Crowthorne, Croydon, Dartford, Dover, Dymchurch, East Grinstead,
Farnborough, Farnham (GU Postcode), Gillingham, Gravesend, Guildford, Ham, Hayes, Haywoods Heath/Haywards
Heath, Herne Bay, Heston, Hounslow, Isleworth, Lancing, Larkfield (Kent), Lewisham, London SE9, London SW8,
London SW12, Maidenhead, Maidstone, Margate, Middlesex, Mitchum, Morden, Newbury, New Malden, Old
Woking, Peckham, Penge, Reading, Redhill, Royal Arsenal (Woolwich, London), Sandwich, Sevenoaks,
Sittingbourne, Slough, Staines, Steyning, Storrington, Sunbury-on-Thames, Swanley (Kent), Sydenham, Tooting,
Tunbridge Wells, Twickenham, Uckfield, Uxbridge, Vauxhall, Walton on Thames, Uckfield, Weybridge, Whyteleaf,
Wimbledon, Windsor, Woking, Wokingham, Worthing
North East:
North East:
Bradford, Brigg, Castleford, Darlington, Doncaster, Grimsby, Harrogate, Hartlepool, Huddersfield, Hull, Killamarsh,
Leeds, Malton, Middlesbrough, Northallerton, Newcastle on Tyne, Retford, Rotherham, Scarborough, Scunthorpe,
Sheffield, Stockton-on-Tees, Thirsk, Whitby, York
North West:
North West:
South Wales:
South West:
South Wales:
Axminster, Barnstaple, Bath, Bodmin, Bridgwater, Bristol, Chard (ONLY IF BIG ORDER), Clevedon,
Aberdare, Aberaman, Abergavenny, Bedwas, Brecon, Cardiff, Chepstow,
Collumpton/Cullumpton/Cullompton, Dorset, Exeter, Falmouth, Honiton, Penryn, Penzance, Plymouth, Cinderford, Ebbw Vale, Hereford, Llanelli, Merthyr Tydfil, Monmouth,
Redruth, Somerset, Stroud, St Austell, Taunton, Tetbury (POSSIBLY SOUTH COAST),Tiverton,
Newport, Port Talbot, Ross-on-Wye, Swansea
Torquay, Truro, Wellington, Weston-Super-Mare
East Midlands:
South Coast:
Midlands:
Alfreton, Alperton,
Atherstone, Burton on
Trent, Chesterfield,
Derby, Leicester,
Lichfield, Lutterworth,
Mansfield, Nottingham,
Nuneaton, Rugby,
Staveley, Tamworth,
Worksop (THIS RUN
ONLY)
Midlands:
East Midlands:
Units 9-11 Lower Road Trading Estate Ledbury Herefordshire HR8 2DJ
Telephone: +44(0) 1531 630068 Fax: +44(0) 1531 636638
3
36
Email: sales@davant.co.uk
www.davant.co.uk