AUTOMATIC DRAINS
WHY USE AUTOMATIC
DRAINS ?
WATER ACCUMULATION

S
59

When compressing air, a compressor


draws in many other substances
including water vapor. The compression
process causes this water vapor to
condense and accumulate in receivers,
tanks and compressed air systems.
The most obvious place for this
condensate to accumulate is in the
compressor tank. In addition to
damaging the tank, this condensate will
also be entrained in the air flow and be
drawn into the compressed air network.
Removing this condensate from the
compressed air system is vitally
important, as even small quantities can
have a significantly detrimental effect on
downstream equipment.

COMPRESSOR OILS
In addition, compressed air is usually
produced from oil-flooded compressors.
This oil gets into the flow of air and can
mix with water vapor, liquid water and
other contaminants to form a thick,
viscous substance even more damaging
to downstream components.
For all these reasons, condensate
removal is crucial to any compressed
air system.

WHY AUTOMATE
THE DRAINAGE
FUNCTION ?
Automating the condensate drainage
function saves operator and maintenance
personnel time and eliminates the
possibility that removal will be forgotten
or overlooked. Automatic drains can also
help manage seasonal fluctuations in
condensate accumulation by varying
GALLONS OF WATER AFTER 8 HOURS FOR A 25HP COMPRESSOR (100 SCFM)
purge cycles and purge times.
Ambient Air
Temperature
F
120
110
100
90
80
70
60
50
40
30
20
10

% Humidity
20%
18.6
14.1
10.5
7.8
5.7
3.9
2.7
2.1
1.2
0.9
0.6
0.3

30%
27.9
21.0
15.6
11.4
8.4
6.0
4.2
3.0
2.1
1.2
0.9
0.5

40%
37.2
27.9
20.7
15.3
11.1
7.8
5.7
3.9
2.7
1.8
1.2
0.7

50%
46.5
35.1
26.1
19.2
13.8
9.9
6.9
4.8
3.3
2.1
1.5
0.8

60%
55.8
42.0
31.2
23.1
16.8
12.0
8.4
6.0
3.9
2.7
1.7
1.0

70%
65.1
48.9
36.6
26.7
19.5
13.8
9.9
6.9
4.8
3.0
1.9
1.2

80%
74.4
55.8
41.7
30.6
22.2
15.9
11.1
7.8
5.4
3.6
2.1
1.4

90%
83.7
63.0
46.8
34.5
24.9
18.0
12.6
8.7
6.0
3.9
2.4
1.5

100%
93.0
69.9
52.2
38.4
27.9
19.8
14.1
9.9
6.6
4.5
2.7
1.8

TOPRING

Condensate removal using automatic


drains is simple and efficient, and can
easily eliminate problems associated
with water and oil condensates.

309

series59(308_323) ENG_2011:Srie 5 ang f

S
59

3/31/11

11:44 AM

Page 310

AUTOMATIC DRAINS
AUTOMATIC DRAIN SELECTION GUIDE
TRAPPING CONDENSATE
Due to the high costs of resulting damages, removing the condensate from compressed air should be a high priority.
There a three different ways to trap condensates:

Zero Air Loss Automatic Drain:


a sensor located in the condensate
collector triggers the draining of the
tank when a set value is reached

ZERO AIR LOSS DRAIN

MECHANICAL DRAIN

Programmable cycle time

Mechanical or float-operated

Fully automatic Intelligent drain

Programmable purge time

Low investment

Functions well with dirty condensate

Large orifice valve ensuring a

Minimum maintenance

Double mounting option

self-cleaning process
High PSI available
Save maintenance time
Reliable condensate drainage

High resistance to rust and dirt

TOPRING

PROGRAMMABLE DRAIN

Mechanical Automatic Drain:


the condensate is collected in a
storage tank. A float opens a valve
when a certain condensate volume
is reached

Energy Saver Zero air loss

310

Programmable Automatic Drain:


a valve operated by a timer switch
opens at fixed interval

(59.200 to 59.208)
Fault and alarm function
Continued electronic surveillance
Voltage peak protection
Save maintenance time
Manage seasonal fluctuations
Magnetically operated model
available (no electricity required)

Initial investment

Limited monitoring possibilities


Possible Compressed air loss
Limited High energy cost

Manage seasonal fluctuations


No monitoring possibilities

series59(308_323) ENG_2011:Srie 5 ang f

3/31/11

11:44 AM

Page 311

AUTOMATIC DRAINS
SELECTING THE PROPER AUTOMATIC DRAIN
Selecting the right automatic drain is a question of several criteria: environment, pressure, temperature, but the main goal should
always be to limit energy cost so a zero air loss drain is always preferable over programmable or float operated drains.

WHY A ZERO AIR LOSS AUTOMATIC DRAIN


IS ALWAYS THE BEST SOLUTION?

Valve operating time too long/operating intervals too short:


valve remains open although all the condensate has been
drained allowing compressed air to escape

If the control of a condensate drain is exclusively time-based,


it employs preset values for valve operation times and intervals.
However, since the amount of condensate in a compressed air
system changes constantly (summer/winter, maximum/part
load), the following problems can occur:

High switching frequency because the condensate collecting


vessel is too small: premature failure without the possibility
of servicing causing compressed air system to back up with
condensate

Valve operating time too short/operating intervals too long:


not enough discharge is drained causing compressed air
system to back up with condensate

S
59

Small valve nozzles are susceptible to contamination: valve


can no longer close causing compressed air to escape

The three following selection guides will help describe the main features of the
different automatic drains available
SELECTION GUIDE FOR ZERO AIR LOSS AUTOMATIC DRAINS
Product
No

59.200
59.202
59.204
59.206
59.208
Main
Characteristics

Automatic drain magnetic


core level control
Non wearing magnetic core level
control for optimized and loss-free
discharge of condensate
Large cross-section diaphragm
ensures that contaminants are
flushed out ensuring a long
service life and fault free valve
operation
Revolving top condensate inlet
offering an additional balance line
connection
Fully encapsulated electronic board
Quiet drainage
no pressure bang

59.500

59.400
Automatic drain
Continuous monitoring
insures fast, effective
discharge
Upper liquid detector
senses when reservoir is
full and triggers purge
Lower detector stops purge
before any compressed air
can be wasted
Continued electronic
surveillance ensure quick
and efficient draining

Automatic drain
magnetically operated
No electricity required
to operate the drain
Uses internal magnetic
forces as its power
source to operate.
Direct operated valve
not diaphragm type

232 PSI

230 PSI

230 PSI

Maximum Ambient
Temperature

140 F (60 C)

120 F (49 C)

120 F (49 C)

3/8 1/2

1/2

1/2

$$$

$$

Inlet connections
(F) NPT
Cost

TOPRING

Maximum Working
Pressure

311

series59(308_323) ENG_2011:Srie 5 ang f

S
59

3/31/11

11:44 AM

Page 312

AUTOMATIC DRAINS
SELECTION GUIDE FOR PROGRAMMABLE AUTOMATIC DRAINS
Product
No

59.350

59.360
Main
Characteristics

59.300
59.310

59.345
59.346

Digital
Electronic
Compact
Ideal for draining
large capacity
Allows true
filter bowls
programming

Y strainer incuded Y strainer incuded

59.325

Electronic
Heavy Duty
Y strainer incuded Compact
Lightweight
Quick and simple
installation
Manual override
button

Heavy duty
Saves maintenance time
Manual override
button
Rust and
corrosion-proof

Maximum Working
Pressure

300 PSI

230 PSI

230 PSI

150 to 300 PSI

200 PSI

Maximum Ambient
Temperature

131 F (55 C)

130 F (54 C)

131 F (55 C)

120 F (49 C)

165 F (75 C)

1/2 (M)
1/4 (F) 1/4 (F)

1/4(F) 1/2(F)

1/4(F)

1 to 120 min.

30 sec to 45 min

1 to 45 min

1 to 60 min

2 sec

0.5 to 10 sec

1 to 15 sec

1 to 30 sec

$$

$$$

$$$

Inlet connections
(F) NPT
Cycle Time
Drain Time

1/2(M) and 1/4(F)

1/2(M) and 1/4(F)

Infinite from
milliseconds to
99 hours
$$

Cost

SELECTION GUIDE FOR MECHANICAL AUTOMATIC DRAINS


Product
No

TOPRING

Main
Characteristics

312

59.445

59.470

59.446

Zinc bowl
Unique self cleaning
poppet ensures reliability
and low maintenance
Piston seal is forced
closed by pressure above
30 PSI

Polycarbonate bowl
Integrated filter element

Zinc bowl
Valve drain
Large capacity drain
Unique self cleaning poppet ensures
reliability and low maintenance
Reliable and accurate draining

Maximum Working
Pressure

175 PSI

140 PSI

250 PSI

Maximum Ambient
Temperature

120 F (49 C)

140 F (60 C)

120 F (49 C)

Inlet connections
(F) NPT

1/2

1/2

1/2

Cost

$$

$$$

series59(308_323) ENG_2011:Srie 5 ang f

3/31/11

11:44 AM

Page 313

AUTOMATIC DRAINS
ZERO AIR LOSS AUTOMATIC DRAIN
WITH MAGNETIC CORE LEVEL CONTROL

CYCLE
TIME

PURGE
TIME
ENERGY SAVER
ZERO AIR LOSS

S
59

PROGRAMMABLE

Magnetic core level control


The magnetic core level control employs fixed switching
points to operate the valve.
The magnetic core signal transmitter position is detected
by non-contact magnetic sensors:
Independent of the condensate type (oil or water)

MAGNETIC CORE
LEVEL CONTROL

Independent of the working pressure.


The collecting vessel integrated in the condensate drain is always used
at optimum efficiency. This results in a minimized number of switching cycles
and in a maximum service life of the drain valve. No calibration required.

BENEFITS
An electronic level controller continuously
monitors the level of condensate. When
the maximum level is reached the drain
valve opens and drains the condensate
from the compressed air system. When a
minimum level is reached, the valve closes
in time before compressed air can escape.
This prevents the loss of compressed air
Large cross-section diaphragm ensures
that contaminants are flushed out ensuring
a long service life and fault free valve
operation.

TYPICAL INSTALLATION

Condensate collecting chamber used at


100 % efficiency
Expels only in the presence of water
without wasting any compressed air
Conserves air supply and reduces
compressor demand

COMPRESSOR

Eliminates the problem of condensation


in pneumatic systems

RECEIVER
TANK

REFRIGERATED
DRYER

OIL/WATER
SEPARATOR

FEATURES
Non wearing magnetic core level control
for optimized and loss-free discharge of
condensate
Integrated dirt screen between level
measurement and drain valve protects
diaphragm valve

Revolving top condensate inlet offering


an additional balance line connection
Condensate line can be connected from
top or side (for models 59.204 to
59.208)
Fully encapsulated electronic board
Quiet drainage sound no pressure
bang
Easy installation and maintenance

Maximum Working Pressure


232 PSI
Working Temperature Range
35 F to 140 F (1,5 C to 60 C)
Voltage
115VAC / 50-60Hz

Capacity
Compressor
refrigeration
Prod.
Connections
aftercooler
dryer
Filter
HxWxL
No
NPT
SCFM
SCFM
SCFM
(in)
59.200
3/8
424
4.33 x 2.64 x 5.75
59.202
1 x 1/2 ; 3/8
141
282
1413
3.97 x 2.64 x 5.47
59.204
2 x 1/2 ; 3/8
247
494
2472
4.80 x 2.64 x 6.14
59.206
2 x 1/2 ; 3/8
1059
2119
10594
5.39 x 2.64 x 6.14
59.208
2 x 1/2 ; 3/8
3532
7063
35315
7.76 x 2.64 x 6.14
Maintenance kit for all models: Prod. No 59.210 includes replacement seals, spring, gasket and
maintenance manual.

TOPRING

Diaphragm valve with large cross


section and condensate pilot control for
extended service life

SPECIFICATIONS

313

series59(308_323) ENG_2011:Srie 5 ang f

S
59

3/31/11

11:44 AM

Page 314

AUTOMATIC DRAINS
ZERO AIR LOSS
AUTOMATIC DRAIN

CYCLE
TIME

PURGE
TIME

COMPLIES
WITH CSA
STANDARDS

ENERGY SAVER
ZERO AIR LOSS

FULLY AUTOMATIC

BENEFITS
Expels only in the presence of water
without wasting any compressed air
Conserves air supply and
reduces demand on the compressor
Eliminates the problem of condensation
in pneumatic systems

FEATURES
Upper liquid detector senses when
reservoir is full and triggers purge
Lower detector stops purge before any
compressed air can be wasted
Continued electronic surveillance
ensures quick and efficient draining of
accumulated liquids
Functions equally well with clear water
or heavily emulsified and dirty
condensate
Large orifice, can drain up to 300 litres
of condensate per hour
Large orifice valve prevents blockage
Automatic re-set protects against
voltage peaks or other electrical supply
problems
Requires no anti-siphon pipeline
Heavy duty construction for prolonged
life
Alarm feature incorporated
LED power indicator
Top or bottom Inlet installation

Prod.
No
59.400

Inlet
Port Size
(F) NPT

Outlet
Port Size
I.D. (Hose Barb)

1/2

5/16

COMPRESSOR TANK

AUTOMATIC DRAIN
ZERO AIR LOSS

Y FILTER
108 mm
133.7 mm

Working Temperature Range


35 F to 120 F (2 C to 49 C)

122.5 mm

SPECIFICATIONS
Maximum Supply Pressure
230 PSI

TOPRING

Connection
1/2 (F) NPT

314

Voltage
115VAC / 1ph / 50/60 Hz
NEMA Rating
NEMA 4
Drainage Capacity
300 litres/hour
Power Cord
6 ft Heavy Duty Grounded
Weight: 3.6 lb

VALVE

CONSTRUCTION
Body Material: Polyamide, Fiberglass
reinforced
Head Material: Aluminium
Valve Internal Parts: Stainless Steel
Seals : Viton

series59(308_323) ENG_2011:Srie 5 ang f

3/31/11

11:44 AM

Page 315

AUTOMATIC DRAINS
MAGNETICALLY OPERATED
ZERO AIR LOSS DRAIN FOR
AIR FILTER APPLICATIONS

CYCLE
TIME

PURGE
TIME

NO ELECTRICITY
REQUIRED

ENERGY SAVER
ZERO AIR LOSS

S
59

PROGRAMMABLE

Designed to remove condensate from


compressed air filters.
Uses internal magnetic forces as its
power source to operate. Ideally suited
for applications where electricity is not
available, not desired or not reliable.
The operation is automatic and there is
zero air loss during the condensate
discharge cycle.

BENEFITS
Zero air loss during the condensate
discharge
No electricity required to operate the drain
Suitable for all types of compressed air
filters
Large (2.0 mm) valve orifice
Direct operated valve not diaphragm type

FEATURES
Ideally suited for applications where
electricity is not available, not desired or
not reliable

Prod.
No
59.500

Inlet
Connection
(F) NPT

Outlet
Connection
(F) NPT

1/2

1/8

Uses internal magnetic forces as its


power source to operate
Designed to remove condensate from
compressed air filters of any size, type
or manufacturer
Operation is automatic and there is zero
air loss during the condensate discharge
cycle

FILTER

CONSTRUCTION
Housing Material: Corrosion resistant
Aluminium
Valve seals: Viton

DRAIN

SPECIFICATIONS

Working Temperature Range


36 F to 120 F (2 C to 49 C)
Inlet Connection
1/2 (F) NPT
Outlet Connection
1/8 (F) NPT
Orifice Size: 2 mm
Weight: 3 lb

TOPRING

Maximum Operating Pressure


230 PSI

315

series59(308_323) ENG_2011:Srie 5 ang f

S
59

3/31/11

11:44 AM

Page 316

AUTOMATIC DRAINS
PROGRAMMABLE
DIGITAL
COMPACT
AUTOMATIC DRAIN

PURGE
TIME

CYCLE
TIME

PROGRAMMABLE

BENEFITS
Allows true programming of drain times
based on rate of condensate generation
Ensures fully automatic and reliable
condensate drainage
Saves maintenance time
Helps conserve air supply and reduces
demand on the compressor
Installation is simple and quick

FEATURES
True digital timer control allows virtually
limitless programming control
Valve can open from millisecond to a
99 hour interval
Counts down to drain times to warn
operator
Combines timer, ball valve, strainer
and drain in one compact package
Simple to install

5.1"
4.6"

Fully automatic - no maintenance

LED indicating power ON or OFF

3.7"

Rugged fire-resistant ABS housing


1"

Stainless Steel inner moving valve parts

1.7"

Large-orifice valve ensuring a


self-cleaning process
Strainer with bypass protects valve and
allows for convenient, easy access and
removal of particles that could block the
valve

APPLICATIONS

TOPRING

Air receivers

316

Refrigerated dryers
Separators
Drop legs

CONSTRUCTION

1/4"
1/4
/ "
/4

1.5"

Solid-state digital timer for long life


and reliability

1/2"
1/2
/ "
/2

Test switch for routine inspection and


depressurisation

SPECIFICATIONS
Maximum Supply Pressure
300 PSI

NEMA Rating
NEMA 4

Maximum Fluid Temperature


190 F (55 C)

Valve Orifice
4 mm

Ambient Temperature Range


36 F to 131 F (2 C to 55 C)

Weight
1.5 lb

Adjustable Cycle and Drain Time

Power Cord

Infinite from milliseconds to 99 hours

6 ft Heavy-Duty Grounded

Voltage
115V / 1ph / 60Hz

Valve Body: Brass


Internals: Stainless Steel
Enclosure : ABS Plastic
Seals: Viton

Prod.
No
59.360

Inlet

Valve
Orifice

1/2 (M) NPT and 1/4 (F) NPT

4 mm

series59(308_323) ENG_2011:Srie 5 ang f

3/31/11

11:44 AM

Page 317

AUTOMATIC DRAINS
COMPACT
ELECTRONIC
AUTOMATIC DRAIN

CYCLE
TIME

PURGE
TIME

1 TO 120
MINUTES

2 SECONDS

COMPLIES
WITH CSA
STANDARDS

S
59

BENEFITS
Ensures fully automatic and
reliable condensate drainage
Saves maintenance time
Helps conserve air supply and
reduces demand on the compressor
Ideal for draining large capacity filter
bowls

FEATURES
Compact and lightweight
Provides reliable and cost-effective
drainage, at regular intervals, of the
liquid and gaseous substances that have
collected in the reservoir (air tanks,
filters, aftercoolers, dryers)
Designed for reliable and cost-effective
operation, may be adjusted to meet
many pneumatic system requirements
Brass solenoid valve, controlled by a
solid state timer, opens and closes the
drain valve
Test switch - for routine inspection
and depressurisation
Solid-state timer for long life and
reliability
LED indicating power ON or OFF
Rugged ABS fire resistant housing
Adjustable DIN connector for 180
rotation
A strainer (with bypass) protects valve
and allows for convenient access and
removal of particles that could block
the valve

APPLICATIONS
Air receivers
Refrigerated dryers
Separators

CONSTRUCTION
Valve Body : Brass
Internals: Brass and Stainless Steel

Working Pressure Range


3 to 230 PSI

Voltage
115V / 1ph / 60Hz

Maximum Fluid Temperature


190 F (88 C)

NEMA Rating
NEMA 4

Ambient Temperature Range


32 F to 130 F (0 C to 54 C)

Valve Orifice
2 mm

Adjustable Cycle Time


1 to 120 minutes

Weight
1.0 lb

Drain Time
2 seconds

Power Cord
6 ft heavy-duty grounded

Enclosure : ABS Plastic


Seals : Viton

Prod.
No
59.350

Inlet
1/2 (M) NPT and 1/4 (F) NPT

Valve
Orifice
2 mm

TOPRING

Drop legs

SPECIFICATIONS

317

series59(308_323) ENG_2011:Srie 5 ang f

S
59

3/31/11

11:44 AM

Page 318

AUTOMATIC DRAINS
MAXDRAIN
COMPACT
ELECTRONIC
AUTOMATIC DRAINS

CYCLE
TIME

PURGE
TIME

30 SEC.
TO 45 MIN.

0.5 TO 10
SECONDS

COMPLIES
WITH CSA
STANDARDS

BENEFITS
Ensure fully automatic and
reliable condensate drainage
Save maintenance time
Help conserve air supply and
reduces demand on the compressor
Installation is simple and quick

FEATURES
Compact design
Cost effective solution for regular,
reliable condensate removal
Designed to eliminate the problem of
condensation in pneumatic systems
Fully automatic - no maintenance
59.345

Simple to install

59.346

Adjustable interval and discharge times


Valve opens 0.5 to 10 seconds in 0.5
to 45 minute cycle times
Test switch - for routine inspection
and depressurisation
Solid-state timer for long life and
reliability
LED indicating power ON or OFF
Rugged fire-resistant ABS housing
Large-orifice valve ensuring a
self-cleaning process
Strainer with bypass (59.345) protects
valve and allows for convenient, easy
access and removal of particles that
could block the valve

APPLICATIONS
Air receivers
Refrigerated dryers
Separators

TOPRING

Drop legs

318

CONSTRUCTION
Valve Body: Brass
Internals: Brass and Stainless Steel

SPECIFICATIONS
Maximum Working Pressure
230 PSI

NEMA Rating
NEMA 4

Maximum Fluid Temperature


190 F (88 C)

Valve Orifice
4 mm

Ambient Temperature Range


36 F to 131 F (2 C to 55 C)

Weight
1.1 lb (1.5 lb with strainer)

Adjustable Cycle Time


30 seconds to 45 minutes

Power Cord
6 ft heavy-duty grounded

Adjustable Drain Time


0.5 to 10 seconds
Voltage
115V / 1ph / 60Hz

Enclosure : ABS Plastic


Seals: Viton

Prod.
No
59.345
59.346

Inlet
1/2 (M) NPT and 1/4 (F) NPT
1/4 (F) NPT

Valve
Orifice
4mm
4mm

Description
With strainer and shut off valve
Drain unit only

series59(308_323) ENG_2011:Srie 5 ang f

3/31/11

11:44 AM

Page 319

AUTOMATIC DRAINS
HEAVY DUTY
ELECTRONIC
AUTOMATIC
DRAINS

CYCLE
TIME

PURGE
TIME

1 TO 45
MINUTES

1 TO 15
SECONDS

S
59

FEATURES
Designed to eliminate the problem
of condensation in pneumatic systems
Quick and simple installation
Compact and lightweight
Manual override button for
quick testing

SEPARATORS

Red Power On light


Green Valve Open light

CONSTRUCTION
Valve Body: Brass
Internals : Brass and Stainless Steel
Diaphragm: EPDM
REFRIGERATED
AIR DRYERS

SPECIFICATIONS
Maximum Working Pressure
1/4 NPT: 300 PSI
1/2 NPT: 150 PSI
Minimum Working Pressure
3 PSI
Maximum Operating Temperature
180 F (82 C)

FILTERS

Maximum Ambient Temperature


120 F (49 C)
Adjustable Cycle Time
1 to 45 minutes
Adjustable Drain Time
1 to 15 seconds
Voltage
110V / 1 ph / 60 hz

Prod.
No
59.300
59.310

Connection
In / Out
(F) NPT
1/4
1/2

AIR STORAGE TANKS

NEMA Rating
NEMA 4
Valve Orifice Size
7/16"
Weight
1.5 lb

TECH TIP
It is strongly recommended to always
install a Y strainer (59.705) ahead
of an external drain. By trapping
large debris and sludge, this will
prevent costly malfunctions and
extend the life of the automatic drain.

or

TOPRING

Power Cord
6 ft heavy-duty grounded

319

series59(308_323) ENG_2011:Srie 5 ang f

S
59

3/31/11

11:44 AM

Page 320

AUTOMATIC DRAINS
ELECTRONIC
AUTOMATIC
DRAIN

CYCLE
TIME

PURGE
TIME

1 TO 60
MINUTES

1 TO 30
SECONDS

BENEFITS
Ensures fully automatic and
reliable condensate drainage
Saves maintenance time
Helps conserve air supply and
reduces demand on the compressor
Installation of the drain is simple
and quick

FEATURES
Automatically drains filters, tanks,
drain legs, aftercoolers, and receivers
A solenoid, controlled by a solid state
timer, opens and closes the drain valve
in 1 to 60 minute cycle times and
1 to 30 second blow-down times.
Both times are individually adjustable.
Manual override switch with indicator
light
Heavy-duty construction
AIR RECEIVER

Rust and corrosion-proof molded


Plastic enclosure
Spring-loaded softseat solenoid which
eliminates valve noise and assures
leak-proof shut off
6' heavy-duty grounded power plug

APPLICATIONS
Air receivers
Separators
Drop legs
Filters
Any water-collection receptacle
in a compressed air system

IN

OUT

SPECIFICATIONS
Maximum Working Pressure
200 PSI

AUTO DRAIN
Y STRAINER

Purge Rate
16 SCFM @ 100 PSIG
Ambient Temperature Range
35 F to 165 F (3 C to 75 C)
Maximum Fluid Temperature
165 F (75 C)
Adjustable Cycle Time
1 to 60 minutes
Adjustable Drain Time
1 to 30 seconds

TOPRING

Voltage
115 V / 1 ph / 60 Hz, .25 amps

320

NEMA Rating
NEMA 1
Weight
1.5 lb

TECH TIP
It is strongly recommended to always
install a Y strainer (59.705) ahead
of an external drain. By trapping large
debris and sludge, this will prevent
costly malfunctions and extend the
life of the automatic drain.

Prod.
No
59.325

Connection
(F) NPT
1/4

A
314

Dimensions (in)
B
C
31516
4316

Cv
0.31

series59(308_323) ENG_2011:Srie 5 ang f

3/31/11

11:44 AM

Page 321

AUTOMATIC DRAINS
MECHANICAL
FLOAT-OPERATED
AUTOMATIC DRAIN

5-5/16"

FEATURES
Automatically expels condensed
moisture and high and low viscosity
liquids from compressed air systems
Piston seal is forced closed by
pressure above 30 PSI
Unique self-cleaning poppet ensures
reliability and low maintenance
High resistance to rust and dirt

S
59

2-1/8"

TYPICAL DROP LEG INSTALLATION

MECHANICAL
AUTO DRAIN

APPLICATIONS

BALL VALVE
Y STRAINER

Can be used on a compressor tank,


receiver tank or drop leg

Prod.
No
59.445

CONSTRUCTION
Bowl : Zinc
Body and Guard : Zinc
Float Mechanism: Plastic

Inlet Port Size


(F) NPT
1/2

TECH TIP
It is strongly recommended to always
install a Y strainer (59.705) ahead
of an external drain. By trapping large
debris and sludge, this will prevent
costly malfunctions and extend the
life of the automatic drain.

SPECIFICATIONS
Maximum Working Pressure
30-175 PSI

Bowl Capacity
4 fl oz (114 ml)

Maximum Working Temperature


120 F (49 C)

Weight
1 lb

MAXDRAIN
MECHANICAL
FLOAT-OPERATED
AUTOMATIC DRAIN
FEATURES
Automatically expels condensed
moisture and high and low viscosity
liquids from compressed air systems
Integrated filter element prevents rust,
scale and large particles from fouling
float mechanism

APPLICATIONS
Can be used on a compressor tank,
receiver tank or drop leg

TYPICAL DROP LEG INSTALLATION


MAXDRAIN

MECHANICAL
AUTO DRAIN

Y STRAINER

Prod.
No
59.470

Bowl : Polycarbonate
Body and Guard : Zinc
Float Mechanism: Plastic

Inlet Port Size


(F) NPT
1/2

TECH TIP

SPECIFICATIONS
Maximum Working Pressure
22-140 PSI

Bowl Capacity
4.4 fl oz (130 ml)

Maximum Working Temperature


41 to 140 F (5 to 60 C)

Weight
3/4 lb

Drain tube should be 4 mm or greater


in diameter and less than 3 feet long.
The drain tube should be on the wall
surface and kept straight.

TOPRING

CONSTRUCTION

BALL VALVE

321

series59(308_323) ENG_2011:Srie 5 ang f

S
59

3/31/11

11:44 AM

Page 322

AUTOMATIC DRAINS
HEAVY DUTY
AUTOMATIC
MECHANICAL
VALVE DRAIN
BENEFITS
Automatically expels condensed
moisture and compressor carry-over
liquids from compressed air systems,
wherever liquids tend to accumulate
Large capacity drain designed with
a unique self-cleaning poppet to insure
high operating reliability with a
minimum of maintenance
Reliable and accurate draining of
high viscosity fluids
High resistance to rust and dirt

FEATURES
External auto drain
Large orifice prevents clogging
Metal bowl with sight glass
Discharge port is tapped 1/4" NPT
for condensate removal
Push-button for manual drain
Threaded bowl for easy removal

APPLICATIONS

Prod.
No
59.446

Inlet
(F) NPT
1/2

Can be used either on receiver


tank or as a drop leg

CONSTRUCTION
COMPRESSOR TANK

Body and Bowl: Zinc


Seals: Buna-N/Nitrile
Drain : Brass

SPECIFICATIONS

MECHANICAL
VALVE DRAIN

Maximum Supply Pressure


250 PSI

TOPRING

Minimum Supply Pressure


30 PSI

322

Maximum Working Temperature


120 F (49 C)
Bowl Capacity
8 fl oz (240 ml)
Weight
2 lb

TECH TIP
It is strongly recommended to always
install a Y strainer (59.705) ahead
of an external drain. By trapping large
debris and sludge, this will prevent
costly malfunctions and extend the
life of the automatic drain.

Y STRAINER

series59(308_323) ENG_2011:Srie 5 ang f

3/31/11

11:44 AM

Page 323

AUTOMATIC DRAINS
BALL VALVE
STRAINERS

S
59

FEATURES
Ball valve strainers provide the
possibility to isolate condensate drains
for maintenance without having to
depressurize the whole system

CONSTRUCTION
Body : Cast Brass

Prod.
No.
59.714

Inlet
(M) NPT
1/2

Outlet
(M) NPT
1/2

Weight
lb
.05

Y STRAINERS
FEATURES
A Y strainer installed ahead of an
external drain traps large debris and
sludge, prevents malfunctions and
extends the life of the automatic drain
3/8" removable plug for quick draining

CONSTRUCTION
Body : Cast Brass

Maximum Working Pressure


300 PSI

Prod.
No
59.700
59.702
59.705

Port Size
(F) NPT
1/4
3/8
1/2

Weight
lb
.27
.28
.29

TOPRING

SPECIFICATIONS

323