Sie sind auf Seite 1von 285

TECHNICAL

CATALOGUE

JAN/2011

CURTAIN - WALL SYSTEM

GENERAL
INFORMATION
CONCEPT

ADVANTAGES

CERTIFICATES

E85

curtain wall system

Concept
85 is a 50 mm faade system.
There are several variations of the system:

1
2
3

classical faade with cover caps

four sided structural glazing

two sided structural glazing

2
3
E 85 technical catalogue
01.2011

1.1

E85

curtain wall system

The high structural stability of the system is


achieved with lowest weight of the profiles.

E 85 is a multifunctional system which can be combined with any kind of glazing and shape as well as
with other materials.
0C

-40C
E 85 has optimum thermal
performance even in
regions with severe weather conditions.

E 85 enables the execution of complex constructions


as roofs, cupolas, atriums, pyramids, conservatories.
ISOTHERM 10C

This system is easy for fabrication in the workshop


and effortless to be assembled on ISOTHERM
site. 13C

ISOTHERM 10C

Tmin 17,75C
0C

0C

ISOTHERM 10C

ISOTHERM 10C

ISOTHERM 13C

ISOTHERM 13C

-40C

ISOTHERM 10C

20C
Tmin 17,75C

20C

Tmax 19,08C

20C

Tmin 13,16C

-40C

Tmax 19,08C

20C

Tmin 13,16C Tmin 17,75C

Tmax 19,08C
20C

ISOTHERM 10C

Tmax 17,44C

Tmax 17,44C

Tmin 13,16C

20C

Tmax 17,44C

The proper selection of thermal spacer reduces the


chances for condensation formation

Additional thermal spacer


for optimum performance

E 85 has effective and proved airtightness and


watertightness, due to large internal drains on
three levels, without discontinuity at the junction of
mullions or transoms, carefully designed accessories

E 85 technical catalogue
01.2011

and specially constructed supplementary profiles for


sealing the perimeter of the faade.
All characteristics of the system are tested in ift
Rosenheim.

1.2

E85

curtain wall system

There is option to insert photovoltaic and


etalbond composite panels within the faade.

85 is also available in anti burglar version,


which is suitable for window displays of bank
offices and financial institutions.

Sun protection panels can be easily installed in


front of the system.

E 85 technical catalogue
01.2011

1.3

E85

curtain wall system

E 85 with inserted openable parts

projected window

parallel opening window

E 85 technical catalogue
01.2011

1.4

E85

curtain wall system

Water drainage principles


3rd level
transom

mullion
D

water
drainage
E
A

specially designed
gasket, which
facilitates water
drainage
C
B

The special geometry of E 85 profiles facilitates


water drainage

Gasket seal (A) and foam seal (B) have firming function and also make water drainage easier.
Drainage fitting (C) enables water drainage when
connecting two mullions.

The good drainage of this system is achieved by two


levels of drainage and by big channels on mullions
and transoms.

E 85 technical catalogue
01.2011

2nd level
transom

New flanges (D) and (E) permit thermal expansion of


the profiles.

1.5

E85

curtain wall system

There is an extended range of options for joining mullions and transoms according to the applied loads
Additional joints can be used case of severe loads
2nd level drainage

E 85 technical catalogue
01.2011

3rd level drainage

1.6

E85

curtain wall system

TEST CERTIFICATES SYSTEM 85


TEST SAMPLE

85
Structural glazing

E85
with cover caps

85
Curtain wall

CHARACTERISTIC

RESULT

STANDARDS

Air permeability

AE

Water tightness
static; dynamic

R7
200 Pa/600 Pa

EN 12152
EN 12153
EN 12154
EN 12155
ENV 13050

Resistance to wind
load design load;
safety load

1,6 kN/m2
2,4 kN/m2

EN 13116
EN 12179

Impact resistance

I5 / E 5

EN 14019

Air permeability

AE

Water tightness
static; dynamic

R 900
200 Pa/600 Pa

EN 12152
EN 12153
EN 12154
EN 12155
ENV 13050

Resistance to wind
load design load;
safety load

1,6 kN/m2
2,4 kN/m2

EN 13116
EN 12179

Impact resistance

I4 / E4

EN 14019

from 0,50 kN
to 6,00 kN

EN 13830
ENV 1999-1-1

0,50 kN/m2
1,00 kN/m2
2,00 kN/m2

EN 13830
ENV 1999-1-1

Dead load ad
glass loads
Resistance
to horizontal loads

NOTIFIED BODY

CERTIFICATE
NUMBER

ift Rosenheim

108 31925 R1e

ift Rosenheim

108 27811

ift Rosenheim

108 33146e

E85
2 Sided structural
glazing

Thermal
transmittance

Uf = 2,1-2,6
W/m2.K

EN ISO 10077-2
EN 12412-2

ift Rosenheim

432 31927 / 1

E85
4 Sided structural
glazing

Thermal
transmittance

Uf = 2,7-3,2
W/m2.K

EN ISO 10077-2
EN 12412-2

ift Rosenheim

432 31927 / 2

E85
with pressure plate

Thermal
transmittance

Uf = 1,6 -2,9
W/m2.K

EN ISO 10077-2
EN 12412-2

ift Rosenheim

432 31927 / 3

E85
with additional thermal
insulation spacer

Thermal
transmittance

Uf = 1,6-2,3
W/m2.K

EN ISO 10077-2
EN 12412-2

ift Rosenheim

432 31927 / 4

E85
with glazing
6-16-4+4 mm

Sound Insulation

Rw = 39 dB

EN ISO 140-3
EN 717-1

Architectural
Technology
Laboratory - Greece

5.402.06

E85
with glazing
4-20-6+6 mm

Sound Insulation

Rw = 41 dB

EN ISO 140-3
EN 717-1

Architectural
Technology
Laboratory - Greece

5.403.06

E85
with cover cap
glazing 6-15-5 mm

Sound Insulation

Rw = 35 dB

EN ISO 140-1
EN 717-1
EN 20140-3

ift Rosenheim

161 30989/V1

E85
with cover cap glazing
13VSG-20-9 VSG

Sound Insulation

Rw = 44 dB

EN ISO 140-1
EN 717-1
EN 20140-3

ift Rosenheim

161 30989/V2

E 85 technical catalogue
01.2011

1.7

E85

curtain wall system


CLASSIFICATION OF CHARACTERISTICS FOR CURTAIN WALLING
ACCORDING TO EN 13830
Characteristic/Value/dimension

Classification/Value

Resistance to wind load


(kN/m2)

npd

Declared values

Self weight
(kN/m2)

npd

Declared values

Resistance against Impact


Internal
Drop height
(mm)

npd

IO
(no information)

I1
(200)

I2
(300)

I3
(450)

I4
(700)

External
Drop height
(mm)

npd

O
(no information)

1
(200)

2
(300)

3
(450)

4
(700)

Air permeability
Test pressure
(Pa)

npd

A1
(150)

A2
(300)

A3
(450)

A4
(600)

AE
>600

Watertightness
Test pressure
(Pa)

npd

R4
(150)

R5
(300)

R6
(450)

R7
(600)

RE
>600

Airborne sound insulation


Rw (C;Ctr)
(dB)

npd

Declared values

Thermal transmittance
Ucw
(W/m2.K)

npd

Declared values

Fire resistance
Integrity (E)
i o, o i, o i

npd

E15

30

E60

E90

Integrity and insulation (EI)


i o, o i, o i

npd

EI15

EI30

EI60

EI90

Equipotentiality

npd

Declared values

Resistance to horizontal loads


(kN at m sill height)

npd

Declared values

E 85 technical catalogue
01.2011

1.8

BUILDING
PHYSICS
DIMENSIONING

FORMULAE

EXAMPLES

E85

curtain wall system

Definition of curtain walling


Curtain walling usually consists of vertical and horizontal structural members, connected together and anchored
to the supporting structure of the building and infilled, to form a lightweight, space enclosing continuous skin,
which provides, by itself or in conjunction with the building construction, all the normal functions of an external
wall, but does not take on any of the load bearing characteristics of the building structure.
The curtain walling shall be sufficiently rigid to resist the declared wind loads for serviceability, both positive and negative. It shall transfer the declared wind loads to the buildings structure, safely, via the fixings
intended for that purpose.
The stated definition is in accordance with European standards EN 13830 and EN 13119.

Liabilities
always be considered by the structural/ faade engineer responsible for the project.

The stated data and methods are provided by ETEM


Building Systems as a guideline for calculating wind
loads, dead loads, thermal transmittance coefficient,
etc.

The solutions presented in these pages are indicative


and can not cover all possible project cases. Because
of that every single project has to be evaluated by the
structural/faade engineer in charge taking into consideration the specific features, such as climate conditions, location, orientation, etc.

The following information does not substitute of all


applicable regulations Eurocodes, harmonized European standards, national or regional building codes.
The specific conditions and technical details of every
particular project have to be taken into consideration.

ETEM Building Systems is not liable for any calculations


and conclusions on the basis of the stated information.
All calculations and specifications must be estimated,
endorsed and guaranteed by architect, engineer, professional or legal entity authorized by law for such
activities.

The right choice of all faade elements- mullions,


transoms, fixing elements, etc as well as any special
requirements regarding stability of the faade must

Material properties
Aluminium alloy

EN AW 6063 F22

Ultimate tensile strength

Rm = 210 N/mm2

Yield strength

Rp0,2 = 160 N/mm2

Modulus of elasticity

Eal = 70 000 N/mm2 = 7.109 kg/m2

Coefficient of thermal expansion

= 0,023 mm/m .K (up to 1,2 mm/m for difference up to 500C)

E 85 technical catalogue
01.2011

2.1

E85

curtain wall system

Wind actions
The main influence over the faade is wind action,
which depends mainly on the height of the curtain
wall and location.

(m)

0- 8
8 - 20
20 - 100
> 100

(m/s)

28,3
35,8
42,0
45,6

(kg/m2)

50
80
110
130

As a guideline, the wind pressure values with respect


to the structure height are given in the table below:

wind pressure

suction in edge zone

cp = 0,8

cp = 0,5
h/b 0,25

cp = 0,7
h/b 0,5

cp = 2,0
b/8 2 m

wp* = 1,25 x 0,8 x q


kN/m2

ws = 0,5 x q
kN/m2

ws = 0,7 x q
kN/m2

ws = 2,0 x q
kN/m2

0,5
0,8
1,1
1,3

0,25
0,4
0,55
0,65

0,35
0,56
0,77
0,91

1,0
1,6
2,2
2,6

(kN/m2)

0,5
0,8
1,1
1,3

where:

*Note: when calculating wind pressure wp the load is


increased with 25%.

h building height, m
b building width, m
v - wind velocity, m/s
q wind load, kg/m2 / kN/m2
w p/s wind pressure / suction, kN/m2
cp correction factor

E 85 technical catalogue
01.2011

suction in middle zone

For calculating wind actions, when the wind velocity


value is given in m/s, the following formula applies:
2
q = v , kg/m2
16

2.2

E85

curtain wall system

Allowable deflections
In accordance with EN 13830 and Eurocode 9 the
allowable deflections are as follows:
Under the declared wind loads the maximum frontal
deflection of the curtain wallings framing members
- mullions and transoms - shall not exceed L/200,

or 15 mm, whichever is the less, when measured between


the points of support or anchorage to the buildings
structure.
The maximum deflection of any main horizontal framing
from vertical loads (dead loads) shall not exceed L/500
or 3 mm, whichever is the less.

For mullions and transoms loaded by wind pressure:

For transoms loaded by dead loads:

f = L , or 0,015 m whichever is the less (EN 13830)


200

f = L , or 0,003m, whichever is the less (EN 13830)


500

Fixing brackets
Fixing brackets must fulfill the following criteria:
- Transfer safely all loads from the faade resulting from the wind pressure, weight of

mullions and transoms and weight of infill panels


- Permit movement of mullions caused by thermal expansion

fixed support

movable support

y = 0 mm

z = 12mm

E 85 technical catalogue
01.2011

y = 12 mm

x = 12 mm

x = 12mm

2.3

z = 0 mm

E85

curtain wall system

Mullions must be fixed using at least two fixing


brackets, which are mounted onto the backing wall
and never on a brick wall.
Mullion is fixed permanently at one point only fixed support. The other one or two fixing points
of mullion must allow movement - movable support.

Fixed support ensures steady fixing of mullions to


the backing wall. It does not allow any movement
of the fixed component after final assembly.
Fixed support bears vertical/dead loads as well as
wind loads acting on a certain part of the structure.

Movable support also ensures fixing of mullions to


the construction but it allows vertical movement of
the mullion caused by temperature changes. Movable
support bears only wind loads acting on the structure.

concrete slab

movable support - B

fixed support - A

E 85 technical catalogue
01.2011

2.4

E85

curtain wall system

Fixed support

Example

Own weight - dead load


V = g. h . b

Initial data:
H = 0-8 m ( middle zone)
g = 0,5 kN/m2
f1 = 1,25
q = 0,5 kN/m2
cp = 0,8 (wind pressure)
cp= - 0,5 ( wind suction )
h = 3m
b = 1,2m

Wind load-pressure
For determining the maximum
permissible wind load the
following formulae apply:
Wp = f1 . q . cp . h/2 . b
Wind load-suction
Ws = q . cp . h/2 . b
where:
V - load, kN
g - weight of mullions, transoms
and infill panels, kN/m2
Wp - wind pressure, kN
Ws - wind suction, kN
f1 - correction factor
q - dynamic load, kN/ m2
cp - correction factor (wind pressure)
h - floor height, m
b - distance between mullions, m
H - buiding height, m

Wpresure/suction

Choosing the the


appropriate
fixing bracket
Choosing
appropriate
fixing bracket
Simply
supported
beam
with
one movable support
Simply supported beam with one fixed andone
one fixed
movableand
support

B
v

h
h/
b

wind load
dead load
A fixed support
B movable support

Fixed support

Own weight - dead load


V = g . h . b = 0,3 . 3 . 1,2 =
= 1,8 kN
Wind load
Wp = f1 . q . cp . h/2 . b =
= 1,25 . 0,5 . 0,8 . ( 0,5 . 3 ) . 1,2 =
= 0,9 kN

Ws = q . cp . h/2 . b =
= 0,5 . (-0,5 ) . (0,5 .3 ) . 1,2 =
= (-0,45 ) = 0,45 kN

Movable support
Wind load-pressure
For determining the maximum
permissible wind load the
following formulae apply:
Wp = f1 . q . cp . h/2 . b

Wind load
Wp = f1 . q . cp . h/2 . b =
= 1,25 . 0,5 . 0,8 . (0,5 . 3) . 1,2 =
= 0,9 kN
Ws = q . cp . h/2 . b =
= 0,5 . (-0,5) . (0,5 . 3) . 1,2 =
= (-0,45 ) = 0,45 kN

Wpresure/suction

Wind load-suction
Ws = q . cp . h/2 . b

B
v

h/
h

Finally we choose the appropriate fixing bracket with bigger bearing capacity
than the calculated value.
Fixing bracket for fixed support must bear both calculated values for dead
load and wind load.
Fixing bracket for movable support must bear just wind load.

Movable support
E 85 technical catalogue
01.2011

2.5

Choosing the appropriate fixing bracket


Continuous simply supported beam

E85

curtain wall system


Choosing the appropriate fixing bracket
Continuous simply supported beam
Example

Wpresure/suction

Fixed support end supports


Own weight - dead load
V = g.h.b

A
v h

Wind load-pressure
For determining the maximum
permissible wind load the
following formulae apply:
Wp = f1 . q . cp . h/2 . b

A
h

h/
b

Initial data:
H = 8 -20 m ( middle zone)
g = 0,5 kN/m2
f1 = 1,25
q = 0,8 kN/m2
cp = 0,8 (wind pressure)
cp= - 0,5 ( wind suction )
h = 3,5m
b = 1,0m

Wind load-suction
Ws = q . cp . h/2 . b

Fixed support

Own weight - dead load


V = g . h . b = 0,5 . 3,5 . 1,0 = 1,75 kN

where:
V - load, kN
g - weight of mullions, transoms
and infill panels, kN/m2
Wp - wind pressure, kN
Ws - wind suction, kN
f1 - correction factor
q - dynamic load, kN/ m2
cp - correction factor (wind pressure)
h - floor height, m
b - distance between mullions, m
H - buiding height, m

Wind load
Wp = f1 . q . cp . h/2 . b =
= 1,25 . 0,8 . 0,8 . ( 0,5 . 3 .5) . 1,0 =
= 1,4 kN
Ws = q . cp . h/2 . b =
= 0,8 . (-0,5 ) . (0,5 .3 ,5) . 1,0 =
= (-0,7 ) = 0,7 kN
Own weight dead load
V =g . h . b =
= 0,5 . 3,5 . 1,0 = 1,75 kN

Movable support
Own weight - dead load
V =g . h . b

Ws = q . cp . h . b =
= 0,8 . (-0,5) . 3,5 . 1,0 =
= (-1,4) = 1,4 kN

Wind load-suction
Ws =q . cp . h . b

wind load
dead load
A fixed support

Finally we choose the appropriate fixing bracket with bigger bearing


capacity than the calculated value.
Fixing bracket for fixed support must bear both calculated values for dead
load and wind load.

Wpresure/suction

E 85 technical catalogue
01.2011

Wind load
Wp = f1 . q . cp . h . b =
= 1,25 . 0,8 . 0,8 . 3,5 . 1,0= 2,8 kN

Wind load-pressure
For determining the maximum
permissible wind load the
following formulae apply:
Wp = f1 . q . cp . h . b

v h
h/
A

h/
h

Movable support

2.6

Choosing the appropriate fixing bracket


Continuous beam with one fixed and two movable supports

E85

curtain wall system


Choosing the appropriate fixing bracket
Continuous beam with one fixed and two movable supports

Wpresure/suction

B
vh

h/
b

A
h

Fixed support

wind load
dead load
A fixed support
B movable support

Movable support ( middle )


Wind load-pressure
For determining the maximum
permissible wind load the
following formulae apply:
Wp = f1 . f2 . q . cp . h . b
Wind load-suction
Ws = f2 . q . cp . h . b

h/

B
vh
B

Wpresure/suction

Own weight - dead load


V=g . 2. h . b =
= 0,5 . 2 . 3,3 . 0,9 =
=2,97 kN
Wind load
Wp = f1 . q . cp . h/2 . b =
= 1,25 . 0,5 . 0,8 . ( 0,5 . 3 .3) . 0,9 =
= 0,74 kN
Ws = q . cp . h/2 . b =
= 0,5 . (-0,5 ) . (0,5 . 3 ,3) . 0,9 =
= (- 3,7 ) = 0,37 kN

Movable support ( end)

Movable support ( end)

Wind load-pressure
For determining the maximum
permissible wind load the
following formulae apply:
Wp = f1 . q . cp . h/2 . b

Wind load
Wp = f1 . f2 . q . cp . h . b =
= 1,25 . 1,25 . 0,5 . 0,8 . 3,3 . 0,9 =
= 1,86 kN

Wind load-suction
Ws = q . cp . h/2 . b

Wind load
Wp = f1 . q . cp . h/2 . b =
= 1,25 . 0,5 . 0,8 .( 0,5 . 3,3 ) . 0,9 =
= 0,74 kN
Ws = q . cp . h/2 . b =
= 0,5 . (-0,5) . ( 0,5 . 3,3 ) . 0,9 =
= (-0,37) = 0,37 kN

Ws = f2 . q . cp . h . b =
= 1,25 . 0,5 . (-0,5) . 3,3 . 0,9 =
= (-0,93) = 0,93 kN
Finally we choose the appropriate fixing bracket with bigger bearing capacity
than the calculated value.
Fixing bracket for fixed support must bear both calculated values for dead
load and wind load.
Fixing bracket for movable support must bear just wind load.

where:
f2 - correction factor

E 85 technical catalogue
01.2011

Initial data:
H = 0-8 m ( middle zone)
g = 0,5 kN/m2
f1 = 1,25
q = 0,5 kN/m2
cp = 0,8 (wind pressure)
cp= - 0,5 ( wind suction )
h = 3,3m
b = 0,9m

where:
V - load, kN
g - weight of mullions, transoms
and infill panels, kN/m2
Wp - wind pressure, kN
Ws - wind suction, kN
f 1 - correction factor
q - dynamic load, kN/ m2
cp - correction factor (wind pressure)
h - floor height, m
b - distance between mullions, m
H - buiding height, m

h/

Movable support ( middle )

Wpresure/suction

h/

Own weight - dead load


V = g . 2h . b

Wind load-suction
Ws = q . cp . h/2 . b

B
v h
B

Example

Wind load-pressure
For determining the maximum
permissible wind load the
following formulae apply:
Wp = f1 . q . cp . h/2 . b

Fixed support

2.7

Choosing the appropriate fixing bracket

E85

curtain
wall
system
Continious supported
beam with
one fixed support in the middle and two movable in the end
Choosing the appropriate fixing bracket
Continuous supported beam with one fixed support in the middle and two movable in the end

Fixed support

Example

Own weight - dead load


V = g . 2h . b

Initial data:
H = 0-8 m ( middle zone)
g = 0,5 kN/m2
f1 = 1,25
q = 0,5 kN/m2
cp = 0,8 (wind pressure)
cp= - 0,5 ( wind suction )
h = 3,2m
b = 1,3m

Wind load-pressure
For determining the maximum
permissible wind load the
following formulae apply:
Wp = f1 . f2 . q . cp . h . b

Wind load-suction
Ws = f2 . q . cp . h . b

Own weight - dead load


V = g . 2h . b =
= 0,5 . 2 . 3,2 . 1,3 = 4,16 kN

where:
V - load, kN
g - weight of mullions, transoms
and infill panels, kN/m2
Wp - wind pressure, kN
Ws - wind suction, kN
f1 - correction factor
f2 - correction factor
q - dynamic load, kN/ m2
cp - correction factor (wind pressure)
h - floor height, m
b - distance between mullions, m
H - buiding height, m

A
h

Wind load
Wp = f1 . f2 . q . cp . h . b =
= 1,25 . 1,25 . 0,5 . 0,8 . 3,2 . 1,3 =
= 2,6 kN
Ws = f2 . q . cp . h . b =
= 1,25 . 0,5 . (-0,5 ) . 3,2 . 1,3 =
= (-1,3) = 1,3 kN

Movable support
Wind load-pressure
For determining the maximum
permissible wind load the
following formulae apply:
Wp = f1 . q . cp . h/2 . b
Wind load-suction
Ws = q . cp . h/2 . b

Wpresure/suction

Wind load
Wp = f1 . q . cp . h/2 . b =
= 1,25 . 0,5 . 0,8 . (0,5 . 3,2) . 1,3 =
= 1,04 kN
Ws = q . cp . h/2 . b =
= 0,5 . (-0,5) . (0,5 . 3,2) . 1,3 =
= (-0,52) = 0,52 kN

B
v h
h/

Wpresure/suction

wind load
dead load
A fixed support
B movable support

Fixed support

B
v h
A
h

Finally we choose the appropriate fixing bracket with bigger bearing capacity
than the calculated value.
Fixing bracket for fixed support must bear both calculated values for dead
load and wind load.
Fixing bracket for movable support must bear just wind load.

h/
b

Movable support

E 85 technical catalogue
01.2011

h/

2.8

E85

curtain wall system

DIMENSIONING OF MULLIONS AND TRANSOMS


profile dimensioning

mullion dimensioning

simply supported beam

transom dimensioning

continuous beam

transom subjected
to wind load

transom subjected
to glazing weight G

entering necessary
data either in:
-formulas
-tables
-ETEM statics

entering necessary
data either in:
-formulas
-tables
-ETEM statics

entering necessary
data either in:
-formulas
-tables
-ETEM statics

entering necessary
data either in:
-formulas
-tables
-ETEM statics

result required
moment of inertia

result required
moment of inertia

result required
moment of inertia

result required
moment of inertia

choosing the appropriate


mullion with Jx
exceeding or equal
to the required Jx

choosing the appropriate


mullion with Jx
exceeding or equal
to the required Jx

choosing the appropriate


transom with Jx
exceeding or equal
to the required Jx

choosing the appropriate


transom with Jy
exceeding or equal
to the required Jy

choose the profile which


characteristics exceed or are equal
to both calculated values Jx and Jy

E 85 technical catalogue
01.2011

2.9

E85

curtain wall system

Selection of mullion
Wind load actions
1. Simply supported beam
Trapezoidal load
The moment of inertia of a mullion, supported at
two points, subjected to wind load is given by the
following equation:

2
4
(a/2)2
Jxa = w . (a/2) . h . 108 . 25 - 40 (a/2)
+16
1920 . Eal . f
h2
h2

a/2

2
2
4
Jxb = w . (b/2) . h . 108 . 25 - 40 (b/2)
+16 (b/2)
2
2
h
h
1920 . Eal . f

where:
Jx - moment of inertia,cm4
w - wind pressure, kg/m2
a, b - distance betweenmullions,m
h - distance between fixing brackets,m
Eal - modulus of elasticity, kg/m2
f - deflection,m

60 . (1,5/2) . 44 . 108 . 25 - 40 . (1,5/2)2 +16 .(1,5/2)2


1920 . 7. 109 . 0,015
42
42

= 138,0 cm4

l
200

2
4
(b/2)2
Jxb = w . (b/2) . h . 108 . 25 - 40 .(b/2)
+16
.
h2
h2
1920 . Eal . f

or 0,015 m whichever is the less (EN 13830)


Total required moment of inertia:

Use ETEM catalogue to choose the appropriate mullion with Jx exceeding or equal to the required Jx.

= 111,8 cm4

Example:

Total required moment of inertia:

Initial data:
a = 1.5 m
b = 1.2 m
h=4m
w = 60 kg/m2
Eal = 7.109 kg/m2
f = l = 4 = 0,02>0,015m
200 200
f = 0,015 m in the following formulae :

Jx = Ja + Jb = 138,0 + 111,8 = 249,8 cm2


The appropriate mullion is E 85104 with
Jx = 252,5 cm4

2.10

60 . (1,2/2) . 44 . 108 . 25 - 40 . (1,2/2)2 +16 .(1,2/2)2


42
42
1920 . 7. 109 . 0,015

Jx = Ja + Jb

E 85 technical catalogue
01.2011

2
4
(a/2)2
Jxa = w . (a/2) . h . 108 . 25 - 40 .(a/2)
+16
.
1920 . Eal . f
h2
h2

For mullions and transoms loaded by wind pressure:


f=

b/2

E85

curtain wall system

2. Continuous beam
Rectangular load
The required moment of inertia of a mullion, supported at three points, subjected to wind load is
given by the following equation:

4
8
Jxa = w . (a/2) . h . 10
185 . Eal . f

a/2

4
8
Jxb = w . (b/2) . h . 10
185 . Eal . f

where:
Jx - moment of inertia,cm4
w - wind pressure, kg/m2
a, b - distance between mullions,m
h - distance between fixing brackets,m
Eal - modulus of elasticity, kg/m2
f - deflection,m
For mullions and transoms loaded by wind pressure:
f=

b/2

l
200

4
8
Jxa = w . (a/2) . h . 10 =
185 . Eal . f

4
8
Jxb = w . (b/2) . h . 10 =
185 . Eal . f

4
8
= 96 . (1,5/2) .93,3 . 10 =
185 . 7 . 10 .0,015

4. 108
= 96 . (1/2) . 3,3
=
9
185 . 7 . 10 .0,015

= 43,9 cm4

= 29,3 cm4

or 0,015 m whichever is the less (EN 13830)


Total required moment of inertia:
Jx = Ja + Jb

Total required moment of inertia:

Use ETEM catalogue to choose the appropriate mullion with Jx exceeding or equal to the required Jx.

Jx = Ja + Jb = 43,9 + 29,3 = 73,2 cm2

Example:

Jx = 104,1 cm4

The appropriate mullion is E 85102 with

Initial data:
a = 1.5 m
b=1m
h = 3,3 m
w = 96 kg/m2
Eal = 7.109 kg/m2
f = l = 3,3 = 0,016>0,015m
200 200
f = 0,015 m in the following formulae :

E 85 technical catalogue
01.2011

2.11

E85

curtain wall system

Selection of transom
Wind load actions
8
Jx = w . (h0/2) . l . 10
120 . Eal . f

l >1
h0

2
2
4
Jx = w . (h0/2) . l . 108 . 25 - 40 . (h0/2)
+16 . (h0l2/2)
2
1920 . Eal . f
l
l

h0

h0

l 1
h0

h0

where:
Jx - moment of inertia,cm4
w - wind pressure, kg/m2
l - length of transom, m
Eal - modulus of elasticity, kg/m2
f - deflection,m
h0 - distance between transoms, m

l
l

The appropriate transom is E 85300 with Jx = 2,7 cm

For mullions and transoms loaded by wind pressure:

Initial data:
l=2m
h0 = 1.5 m
w = 60 kg/m2
Eal = 7.109 kg/m2

l
f=
200
or 0,015 m whichever is the less (EN 13830)

l = 2 = 1,33 > 1
1,5
h0

Use ETEM catalogue to choose the appropriate transom with Jx exceeding or equal to the required Jx.

Example:

f=

Initial data:
l = 1,2 m
h0 = 3m
w = 60 kg/m2
Eal = 7.109 kg/m2

f = 0, 01 m in the following formula :


2
2
4
Jx = w . (h0/2) . l . 108 . 25 - 40 . (h02/2) +16 . (h02/2) =
l
l
1920 . Eal . f

l = 1,2 = 0,41
3
h0
f=

l = 1,2 = 0,006 >0,015m


200 200

60 . (1.5/2) . 24 . 108 . 25 - 40 . (1,5/2)2+16 . (1.5/2)2 =


22
22
1920 . 7 . 109 . 0,01

= 11,6 cm4
The appropriate transom is E 85302 with Jx = 19,5 cm

f = 0, 006 m in the following formula :

Important note : This selection of transoms is not final!


We choose the appropriate profile which characteristics
exceed or are equal to both calculated values Jx and Jy.

8
8
Jx = w . (h0/2) . l . 10 = 60 . (3/2) . 1.2 9. 10 = 2,1 cm4
120 . Eal . f
120 . 0,006 . 10 . 7

E 85 technical catalogue
01.2011

l = 2 = 0,01 < 0,015m


200 200

2.12

E85

curtain wall system

Calculation of the required glass pane thickness


Weight of the glass pane G is calculated as follows:
G=t.

glass

. lg . hg

where:
t - minimum theoretical thickness, mm
glass - specific weight of glass = 2,5 kg/m2 x mm
lg - the smallest dimension of the glass pane,m
hg - the largest dimension of the glass pane,m

t=

10 . lg . hg . w
72

10 . 2 .1,5 . 60
= 5mm
72

For double glazing treq = 5 . 1,5 = 7,5 mm

For single glass the minimum thickness is given by


the following equations:

According to ETAG 002 the minimum thickness of the


glass panes for curtain walls is 6 mm.

Because of that we choose double glazing 6/14/6.


hg

10 . lg . hg . w
t=
72

lg

where:
w - wind pressure,kg/m2
hg

t=

<3

lg

lg . 10 . w
4,9

For double glazing, the total thickness of both glass


panel is equal to the thickness of a single glass
pane (evaluated using the above equations) multiplied
by 1.5
For triple glazing, the total thickness of both glass
panel is equal to the thickness of a single glass
pane (evaluated using the above equations) multiplied
by 1.7.
Always consult facade engineer or glazing manufacturer when calculating required glazing thickness and
maximum allowable dimensions.

Sample
Initial data:
lg = 2 m
hg = 1,5 m
w = 60 kg/m2
hg
lg

1,5
2

= 0,75 3

E 85 technical catalogue
01.2011

2.13

E85

curtain wall system

Glass pane weight


The required moment of inertia of a transom due to
the weight of the glass pane is given by:

G
G/2

8
Jy1 = G . a . 10 . (3 . l2 - 4 . a2)
48 . Eal . f1

The distance a of the glazing supports of the glass


pane is a= 0.150 m

Sample
Initial data:
t = 12mm
glass = 2,5 kg/m2x mm
lg = 2m
hg = 1,5m
Eal = 7.109 kg/m2
a = 0,150 m

The required moment of inertia of a transom subjected to self weight loading is given by:
4
8
Jy2 = 5 . q . l . 10
384 . Eal . f2

where:
G - weight of glass pane, kg
l - length of transom, m
q - weight of transom per linear meter, kg/m

G = t . glass . lg . hg = 12 . 2,5 . 2 . 1,5 = 90 kg


f=

l = 2 = 0,004 > 3 m
500 500
f = 0,003 m in the following formula:

For transoms loaded by dead loads:

l
500

8
Jy1 = G . a . 10 . (3 . l2 - 4 . a2) =
48 . Eal . f

or 0,003m, whichever is the less (EN 13830)

Total required moment of inertia:

90 . 0,150 . 108 . (3 . 22 - 4 . 0,1502) =


48 . 7 . 109 . 0,003

= 15,9 cm4

Jy = Jy1 + Jy2
Use ETEM catalogue to choose the appropriate transom with Jy exceeding or equal to the required Jy.

We choose the appropriate profile which characteristics


exceed or are equal to both calculated values
Jx = 19,5 cm4 and Jy = 15,9 cm4

Use ETEM catalogue to choose the appropriate


profile which characteristics exceed or are equal to
both calculated values Jx and Jy.

E 85 technical catalogue
01.2011

a
l

Self weight

f=

G/2

The appropriate transom is E 85303 with


Jx = 45,8 cm4 and Jy = 21,5 cm4

2.14

E85

curtain wall system

Thermal transmittance coefficient Ucw of curtain wall


Ucw =

Ag .Ug + Ap.Up + Af.Uf + lg.g + lp.p


Ag +Af+Ap

U cw thermal transmittance of the curtain wall,


(W /m2.K)
U g thermal transmittance of the glass, (W /m2.K)
U p thermal transmittance of the panel, (W /m2 .K)
U f thermal transmittance of the aluminium profile,
(W /m2.K)
I g total length of the glass spacer, (m)
I p total length of the panel spacer, (m)
g linear thermal transmittance of the glass
spacer, (W/m.K)
p linear thermal transmittance of the panel
spacer, (W/m.K)
A g visible glass area, (m2)
A p visible panel area, (m2)
Af aluminium frame area, (m2)
U cw is calculated by formula (1)
U g is given by the glass manufacturer
U f is given by the manufacturer of the aluminium
profiles
Up is given by the panel manufacturer
R thermal resistance, (m2 .K / W)
d panel thickness, (m)
l -thermal conductivity, (W/m. K)

Aw
Af,i

Uf

Ag
2

Ag,a Ug

R= d

1
-1

44

Af Am Af

Am

22

55
Am

Af
At
1

33

Ag
6

66
At

E 85 technical catalogue
01.2011

U= 1
R

Ap
3

L1

Af,a

L L2
4

Ag,i

Ig

6
L3

(1)

2.15

At
Af

E85

curtain wall system

THERMAL TRANSMITTANCE COEFFICIENT OF DIFFERENT PROFILE COMBINATIONS


Test specimen
= 0.9

E 85 SG with
press border

E 85 SG

E 85

E 85 with
ET.080173.00

E 85 technical catalogue
01.2011

Profile Number

Beam

1a: 31927- S1-01a


2a: 31927- S1-02a
3a: 31927- S1-03a
4a: 31927- S1-04a
5a: 31927- S1-05a
6a: 31927- S1-06a
7a: 31927- S1-07a
8a: 31927- S1-08a
9a: 31927- S1-09a
10a: 31927- S1-10a
1a: 31927- S2-01a
2a: 31927- S2-02a
3a: 31927- S2-03a
4a: 31927- S2-04a
5a: 31927- S2-05a
6a: 31927- S2-06a
7a: 31927- S2-07a
8a: 31927- S2-08a
9a: 31927- S2-09a
10a: 31927- S2-10a
1a: 31927- S3-01a
2a: 31927- S3-02a
3a: 31927- S3-03a
4a: 31927- S3-04a
5a: 31927- S3-05a
6a: 31927- S3-06a
7a: 31927- S3-07a
8a: 31927- S3-08a
9a: 31927- S3-09a
10a: 31927- S3-10a
11a: 31927- S3-11a
12a: 31927- S3-12a
13a: 31927- S3-13a
14a: 31927- S3-14a
15a: 31927- S3-15a
1a: 31927- S4-01a
2a: 31927- S4-02a
3a: 31927- S4-03a
4a: 31927- S4-04a
5a: 31927- S4-05a
6a: 31927- S4-06a
7a: 31927- S4-07a
8a: 31927- S4-08a
9a: 31927- S4-09a
10a: 31927- S4-10a
11a: 31927- S4-11a
12a: 31927- S4-12a
13a: 31927- S4-13a
14a: 31927- S4-14a
15a: 31927- S4-15a

E 85100
E 85103
E 85107
E 85301
E 85303
E 85307
E 85100
E 85107
E 85301
E 85307
E 85100
E 85103
E 85107
E 85301
E 85303
E 85307
E 85100
E 85107
E 85301
E 85307
E 85100
E 85103
E 85107
E 85301
E 85303
E 85307
E 85360
E 85354
E 85359
E 85100
E 85107
E 85301
E 85307
E 85360
E 85359
E 85100
E 85103
E 85107
E 85301
E 85303
E 85307
E 85360
E 85354
E 85359
E 85100
E 85107
E 85301
E 85307
E 85360
E 85359

2.16

Pressure
plate
E
E
E
E
E
E
E
E
E
E

E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E

85700
85700
85700
85700
85700
85700
85700
85700
85700
85700
85700
85700
85700
85700
85700
85700
85700
85700
85700
85700
85700
85700
85700
85700
85700
85700
85700
85700
85700
85700
85700
85700
85700
85700
85700
85700
85700
85700
85700
85700

Cover
profile
E
E
E
E
E
E
E
E
E
E

E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E

85714
85714
85714
85714
85714
85714
85714
85714
85714
85714
85714
85714
85714
85714
85714
85714
85714
85714
85714
85714
85714
85714
85714
85714
85714
85714
85714
85714
85714
85714
85714
85714
85714
85714
85714
85714
85714
85714
85714
85714

Transom
depth (mm)

Uvalue

50
110
200
29
69
159
50
200
29
159
50
110
200
29
69
159
50
200
29
159
56
116
206
35
75
165
15
95
205
50
200
29
159
15
205
60
120
210
39
79
169
15
95
205
50
200
29
159
15
205

2,2
2,3
2,3
1,9
2,0
2,1
2,1
2,3
1,9
2,1
2,5
2,7
2,8
2,3
2,4
2,5
2,5
2,7
2,2
2,5
2,5
2,6
2,7
2,2
2,3
2,4
2,0
2,2
2,3
1,9
2,1
1,7
1,9
1,5
1,6
1,9
2,0
2,1
1,9
1,9
2,0
1,8
2,0
2,0
1,5
1,6
1,4
1,5
1,3
1,5

TABLES
LIST OF PROFILES

CHARACTERISTICS

E 85

curtain wall system


code

description

length
weight
ext. perimeter
vis. perimeter

profile

50
X
Y

50

E 85100 mullion

66

70
X
Y

50

E 85101 mullion

86

90

50

E 85102 mullion

106

110
X
Y

50

E 85103 mullion

126

130
X
Y

50

E 85104 mullion

146

160

50

E 85105 mullion

176

E 85 technical catalogue
01.2011

statical values

cm4
cm3
cm
cm

6,6 m
2006 g/m
448 mm
149 mm

Ix =
Wx =
ex =
ix =

27,70
6,96
2,50
1,93

cm4
cm3
cm
cm

Iy =
Wy =
y =
iy =

19,39
7,75
3,98
1,62

6,6 m
2211 g/m
488 mm
189 mm

Ix =
Wx =
ex =
ix =

58,04 cm4
12,19 cm3
2,50 cm
2,66 cm

Iy =
Wy =
y =
iy =

23,79 cm4
9,51 cm3
4,76 cm
1,70 cm

6,6 m
2417 g/m
528 mm
229 mm

Ix = 104,15 cm4
Wx = 18,65 cm3
ex =
2,50 cm
ix =
3,41 cm

Iy =
Wy =
y =
iy =

28,19 cm4
11,27 cm3
5,58 cm
1,78 cm

6,6 m
2665 g/m
568 mm
269 mm

Ix = 169,00 cm4
Wx = 26,15 cm3
ex =
2,50 cm
ix =
4,14 cm

Iy =
Wy =
y =
iy =

33,43
13,37
6,46
1,84

6,6 m
2881 g/m
608 mm
309 mm

Ix = 252,55 cm4
Wx = 34,40 cm3
ex =
2,50 cm
ix =
4,87 cm

Iy =
Wy =
y =
iy =

38,03 cm4
15,21 cm3
7,34 cm
1,89 cm

6,6 m
3205 g/m
668 mm
369 mm

Ix = 417,97 cm4
Wx = 46,90 cm3
ex =
2,50 cm
ix =
5,93 cm

Iy =
Wy =
y =
iy =

44,95 cm4
17,98 cm3
8,91 cm
1,95 cm

3.1

cm4
cm3
cm
cm

E 85

curtain wall system


code

description

length
weight
ext. perimeter
vis. perimeter

profile

180

6,6 m
4628 g/m
708 mm
409 mm

Ix = 752,98 cm4
Wx = 74,89 cm3
ex =
2,50 cm
ix =
6,63 cm

Iy =
Wy =
y =
iy =

60,74
24,30
10,06
1,88

cm4
cm3
cm
cm

6,6 m
5165 g/m
748 mm
449 mm

Ix = 1003,76 cm4
Wx = 91,01 cm3
ex =
2,50 cm
ix =
7,24 cm

Iy =
Wy =
y =
iy =

71,32
28,53
11,03
1,93

cm4
cm3
cm
cm

6,6 m
6423 g/m
748 mm
449 mm

Ix = 1326,00 cm4
Wx = 116,21 cm3
ex =
2,50 cm
ix =
7,47 cm

Iy =
Wy =
y =
iy =

80,93
32,37
11,41
1,85

cm4
cm3
cm
cm

6,6 m
8416 g/m
808 mm
509 mm

Ix = 2161,67 cm4
Wx = 162,85 cm3
ex =
2,50 cm
ix =
8,33 cm

Iy =
Wy =
y =
iy =

110,05
44,02
13,27
1,88

cm4
cm3
cm
cm

6,6 m
1320 g/m
382 mm
114 mm

Ix =
Wx =
ex =
ix =

33,69 cm4
6,96 cm3
1,44 cm
2,62 cm

Iy =
Wy =
y =
iy =

2,70
1,87
4,84
0,74

cm4
cm3
cm
cm

6,6 m
1536 g/m
422 mm
134 mm

Ix =
Wx =
ex =
ix =

60,99cm4
10,58 cm3
1,41 cm
3,27 cm

Iy =
Wy =
y =
iy =

3,40
2,40
5,77
0,77

cm4
cm3
cm
cm

X
Y

50

E 85106 mullion

196

200

50

E 85107 mullion

216

200
X

50

E 85108 mullion

216

230
X
Y

50

E 85109 mullion

split

E 85152 mullion

22.5

246

X
Y

split

E 85153 mullion

22.5

90

X
Y

110

E 85 technical catalogue
01.2011

statical values

3.2

E 85

curtain wall system


description

profile

22.5

code

length
weight
ext. perimeter
vis. perimeter

split

E 85154 mullion

X
Y

split

E 85155 mullion

22.5

130

X
Y

160

suppl.
profile for
E 85150 split
mullion

32

68.8

suppl.
profile for
split
mullion

X
Y

32

E 85151

statical values

6,6 m
1752 g/m
462 mm
154 mm

Ix =
Wx =
ex =
ix =

cm4
cm3
cm
cm

Iy =
Wy =
y =
iy =

4,09 cm4
2,94 cm3
6,71 cm
0,79 cm

6,6 m
2076 g/m
523 mm
184 mm

Ix = 182,37 cm4
Wx = 22,39 cm3
ex =
1,37 cm
ix =
4,87 cm

Iy =
Wy =
y =
iy =

5,12 cm4
3,75 cm3
8,15 cm
0,82 cm

6,6 m
1004 g/m
343 mm
0 mm

Ix =
Wx =
ex =
ix =

cm4
cm3
cm
cm

Iy =
Wy =
y =
iy =

1,56
0,90
3,55
0,65

cm4
cm3
cm
cm

6,6 m
230 g/m
91 mm
33 mm

Ix =
Wx =
ex =
ix =

0,10 cm4
0,10 cm3
1,62 cm
0,35 cm

Iy =
Wy =
y =
iy =

0,53
0,33
1,07
0,79

cm4
cm3
cm
cm

6,6 m
2311 g/m
643 mm
94 mm

Ix =
Wx =
ex =
ix =

36,82 cm4
8,70 cm3
2,51 cm
2,08 cm

Iy =
Wy =
y =
iy =

99,63
14,85
1,39
3,92

14,00
3,95
1,72
1,94

13.5

35.3
Y

50

mullion for

E 85120 substructure

E 19641

cover
cap

E 85 technical catalogue
01.2011

7.5

81

26.4

6,6 m
130 g/m
81 mm
26 mm

3.3

18,31 cm4
7,29 cm3
4,23 cm
1,46 cm

E 85

curtain wall system


code

description

length
weight
ext. perimeter
vis. perimeter

profile

statical values

Ix = 128,93 cm4
Wx = 20,80 cm3
ex =
6,20 cm
ix =
3,12 cm

Iy = 128,93 cm4
Wy = 20,80 cm3
y =
6,20 cm
iy =
3,12 cm

6,6 m
3610 g/m
650 mm
333 mm

Ix = 176,02 cm4
Wx = 27,17 cm3
ex =
7,06 cm
ix =
3,63 cm

Iy = 216,12 cm4
Wy = 30,62 cm3
y =
6,48 cm
iy =
4,02 cm

6,6 m
999 g/m
313 mm
19 mm

Ix =
Wx =
ex =
ix =

6,14
2,79
2,50
1,29

cm4
cm3
cm
cm

Iy =
Wy =
y =
iy =

5,17 cm4
2,07 cm3
2,20 cm
1,18 cm

6,6 m
986 g/m
312 mm
42 mm

Ix =
Wx =
ex =
ix =

7,26 cm4
2,54 cm3
1,62 cm
1,41 cm

Iy =
Wy =
y =
iy =

3,89
2,41
2,86
1,03

cm4
cm3
cm
cm

6,6 m
810 g/m
226 mm
29 mm

Ix =
Wx =
ex =
ix =

3,50
1,38
2,53
1,08

cm4
cm3
cm
cm

Iy =
Wy =
y =
iy =

3,50
1,38
2,53
1,08

cm4
cm3
cm
cm

6,6 m
972 g/m
240 mm
0 mm

Ix =
Wx =
ex =
ix =

3,38
1,89
1,79
0,97

cm4
cm3
cm
cm

Iy =
Wy =
y =
iy =

3,38
1,89
1,79
0,97

cm4
cm3
cm
cm

106
90

E 85130 mullion 90

6,6 m
3572 g/m
859 mm
259 mm

90
106

90

141.2

E 85135 mullion 135

90
119.7

50

suppl.
E 85140 mullion
profile

40.1

30

split

E 85141 rotating
mullion

55.6

48
Y

48.2

inner
E 85142 suppl.
mullion
profile 90

48.2

E 85 technical catalogue
01.2011

.3
44
Y

35.7

outer
E 85143 suppl.
mullion
profile 90

35.7

3.4

E 85

curtain wall system


code

description

length
weight
ext. perimeter
vis. perimeter

profile

15

50

level
E 85300 2nd
transom

31

29

50

level
E 85301 2nd
transom

45

49
X
Y

50

level
E 85302 2nd
transom

65

69
X
Y

50

level
E 85303 2nd
transom

85

89
X
Y

50

level
E 85304 2nd
transom

105

109
X
Y

50

level
E 85305 2nd
transom

125

E 85 technical catalogue
01.2011

statical values

6,01 m
1015 g/m
300 mm
79 mm

Ix =
Wx =
ex =
ix =

2,78
1,33
2,50
0,86

cm4
cm3
cm
cm

Iy =
Wy =
y =
iy =

7,64 cm4
3,06 cm3
2,10 cm
1,43 cm

6,01 m
1293 g/m
330 mm
107 mm

Ix =
Wx =
ex =
ix =

7,12 cm4
2,76 cm3
2,50 cm
1,22 cm

Iy =
Wy =
y =
iy =

11,55 cm4
4,62 cm3
2,61 cm
1,55 cm

6,01 m
1455 g/m
370 mm
147 mm

Ix =
Wx =
ex =
ix =

19,52
6,00
2,50
1,90

cm4
cm3
cm
cm

Iy =
Wy =
y =
iy =

15,08
6,03
3,26
1,67

6,01 m
1785 g/m
410 mm
187 mm

Ix =
Wx =
ex =
ix =

45,83
10,54
2,50
2,64

cm4
cm3
cm
cm

Iy =
Wy =
y =
iy =

21,60 cm4
8,64 cm3
4,35 cm
1,81 cm

6,01 m
2276 g/m
450 mm
227 mm

Ix =
Wx =
ex =
ix =

98,87
18,06
2,50
3,42

cm4
cm3
cm
cm

Iy =
Wy =
y =
iy =

26,45
10,58
5,47
1,77

cm4
cm3
cm
cm

6,01 m
2492 g/m
490 mm
267 mm

Ix = 160,52 cm4
Wx = 25,02 cm3
ex =
2,50 cm
ix =
4,17 cm

Iy =
Wy =
y =
iy =

31,06
12,42
6,42
1,83

cm4
cm3
cm
cm

3.5

cm4
cm3
cm
cm

E 85

curtain wall system


code

description

length
weight
ext. perimeter
vis. perimeter

profile

129
X
Y

50

level
E 85306 2nd
transom

145

159
X
Y

50

level
E 85307 2nd
transom

statical values

cm4
cm3
cm
cm

6,01 m
2708 g/m
530 mm
307 mm

Ix = 240,58 cm4
Wx = 32,66 cm3
ex =
2,50 cm
ix =
4,90 cm

Iy =
Wy =
y =
iy =

35,67
14,27
7,37
1,89

6,01 m
3032 g/m
590 mm
367 mm

Ix = 398,72 cm4
Wx = 45,28 cm3
ex =
2,50 cm
ix =
5,96 cm

Iy =
Wy =
y =
iy =

42,59 cm4
17,04 cm3
8,81 cm
1,95 cm

6,01 m
1080 g/m
283 mm
195 mm

Ix =
Wx =
ex =
ix =

22,08
5,85
2,90
2,35

cm4
cm3
cm
cm

Iy =
Wy =
y =
iy =

20,50
7,07
3,78
2,27

6,01 m
1229 g/m
323 mm
235 mm

Ix =
Wx =
ex =
ix =

43,64 cm4
9,25 cm3
2,90 cm
3,10 cm

Iy =
Wy =
y =
iy =

24,98 cm4
8,61 cm3
4,72 cm
2,34 cm

6,01 m
1380 g/m
363 mm
275 mm

Ix =
Wx =
ex =
ix =

74,28 cm4
13,10 cm3
2,90 cm
3,81 cm

Iy =
Wy =
y =
iy =

29,47 cm4
10,16 cm3
5,67 cm
2,40 cm

6,01 m
1531 g/m
403 mm
315 mm

Ix =
Wx =
ex =
ix =

115,13 cm4
17,37 cm3
2,90 cm
4,50 cm

Iy =
Wy =
y =
iy =

33,95 cm4
11,71 cm3
6,63 cm
2,45 cm

175

X
Y

58

2nd level
E 85600 suppl.
transom

cm4
cm3
cm
cm

69

X
Y

58

2nd level
E 85601 suppl.
transom

89

X
Y

58

2nd level
E 85602 suppl.
transom

109

X
Y

58

2nd level
E 85603 suppl.
transom

129

E 85 technical catalogue
01.2011

3.6

E 85

curtain wall system


code

description

length
weight
ext. perimeter
vis. perimeter

profile

statical values

6,01 m
605 g/m
204 mm
62 mm

Ix =
Wx =
ex =
ix =

0,41 cm4
0,35 cm3
2,50 cm
0,43 cm

Iy =
Wy =
y =
iy =

3,78 cm4
1,51 cm3
1,18 cm
1,30 cm

6,01 m
948 g/m
221 mm
79 mm

Ix =
Wx =
ex =
ix =

1,49
0,94
2,50
0,65

cm4
cm3
cm
cm

Iy =
Wy =
y =
iy =

7,42
2,97
1,58
1,45

6,01 m
1164 g/m
261 mm
119 mm

Ix =
Wx =
ex =
ix =

8,70
3,69
2,50
1,42

cm4
cm3
cm
cm

Iy =
Wy =
y =
iy =

12,03 cm4
4,81 cm3
2,36 cm
1,67 cm

6,01 m
1380 g/m
301 mm
159 mm

Ix =
Wx =
ex =
ix =

24,25 cm4
7,37 cm3
2,50 cm
2,18 cm

Iy =
Wy =
y =
iy =

16,64
6,65
3,29
1,80

cm4
cm3
cm
cm

6,01 m
1874 g/m
341 mm
199 mm

Ix =
Wx =
ex =
ix =

58,19 cm4
12,82 cm3
2,50 cm
2,90 cm

Iy =
Wy =
y =
iy =

21,49
8,60
4,54
1,76

cm4
cm3
cm
cm

6,01 m
2090 g/m
381 mm
239 mm

Ix = 102,48 cm4
Wx = 18,46 cm3
ex =
2,50 cm
ix =
3,64 cm

Iy =
Wy =
y =
iy =

26,10 cm4
10,44 cm3
5,55 cm
1,84 cm

50

level
E 85350 3rd
transom

16

15
50

level
E 85360 3rd
transom

cm4
cm3
cm
cm

25

35

50

level
E 85351 3rd
transom

45

55

50

level
E 85352 3rd
transom

65

75

X
Y

50

level
E 85353 3rd
transom

85

95
X
Y

50

level
E 85354 3rd
transom

105

E 85 technical catalogue
01.2011

3.7

E 85

curtain wall system


code

description

length
weight
ext. perimeter
vis. perimeter

profile

115

6,01 m
2306 g/m
421 mm
279 mm

Ix = 162,24 cm4
Wx = 24,72 cm3
ex =
2,50 cm
ix =
4,36 cm

Iy =
Wy =
y =
iy =

30,71 cm4
12,29 cm3
6,56 cm
1,90 cm

6,01 m
2522 g/m
461 mm
319 mm

Ix = 239,09 cm4
Wx = 31,58 cm3
ex =
2,50 cm
ix =
5,06 cm

Iy =
Wy =
y =
iy =

35,32 cm4
14,13 cm3
7,57 cm
1,95 cm

6,01 m
2846 g/m
521 mm
379 mm

Ix = 389,88 cm4
Wx = 42,93 cm3
ex =
2,50 cm
ix =
6,08 cm

Iy =
Wy =
y =
iy =

42,24
16,90
9,08
2,00

cm4
cm3
cm
cm

6,01 m
3062 g/m
561 mm
419 mm

Ix = 516,42 cm4
Wx = 51,19 cm3
ex =
2,50 cm
ix =
6,75 cm

Iy =
Wy =
y =
iy =

46,85
18,74
10,09
2,03

cm4
cm3
cm
cm

6,01 m
3278 g/m
601 mm
459 mm

Ix = 665,65 cm4
Wx = 60,01 cm3
ex =
2,50 cm
ix =
7,41 cm

Iy =
Wy =
y =
iy =

51,46
20,58
11,09
2,06

cm4
cm3
cm
cm

6,01 m
3448 g/m
661 mm
519 mm

Ix = 882,24 cm4
Wx = 71,59 cm3
ex =
2,50 cm
ix =
8,31 cm

Iy =
Wy =
y =
iy =

58,94 cm4
23,58 cm3
12,32 cm
2,15 cm

50

level
E 85355 3rd
transom

statical values

125

135
X

50

level
E 85356 3rd
transom

145

165
X
Y

50

level
E 85357 3rd
transom

175

185
X
Y

50

level
E 85358 3rd
transom

195

205
X
Y

50

level
E 85359 3rd
transom

215

235
X
Y

50

level
E 85369 3rd
transom

245

E 85 technical catalogue
01.2011

3.8

E 85

curtain wall system


code

description

length
weight
ext. perimeter
vis. perimeter

profile

statical values

21.2
X
Y

50

3rd level
E 85380 hidden
transom

21.2

42

level
E 85320 2nd
split transom

29
45

40

level
E 85370 3rd
split transom
55
65

68.9

suppl.
E 85670 profile
for E 85370

6,01 m
820 g/m
175 mm
91 mm

Ix =
Wx =
ex =
ix =

1,67
1,54
2,50
0,74

cm4
cm3
cm
cm

Iy =
Wy =
y =
iy =

8,74
3,50
1,09
1,70

cm4
cm3
cm
cm

6,01 m
1131 g/m
312 mm
60 mm

Ix =
Wx =
ex =
ix =

7,62 cm4
3,14 cm3
2,40 cm
1,35 cm

Iy =
Wy =
y =
iy =

4,98
2,08
2,43
1,09

cm4
cm3
cm
cm

6,01 m
1061 g/m
341 mm
77 mm

Ix =
Wx =
ex =
ix =

cm4
cm3
cm
cm

Iy =
Wy =
y =
iy =

5,21 cm4
2,04 cm3
3,34 cm
1,15 cm

6,01 m
791 g/m
294 mm
13 mm

Ix =
Wx =
ex =
ix =

8,56 cm4
2,74 cm3
3,44 cm
1,71 cm

Iy =
Wy =
y =
iy =

6,26 cm4
1,82 cm3
3,12 cm
1,46 cm

6,01 m
1329 g/m
415 mm
186 mm

Ix =
Wx =
ex =
ix =

38,50 cm4
7,97 cm3
3,19 cm
2,77 cm

Iy =
Wy =
y =
iy =

8,12 cm4
1,33 cm3
4,83 cm
1,34 cm

6,01 m
886 g/m
339 mm
185 mm

Ix =
Wx =
ex =
ix =

12,87 cm4
3,55 cm3
3,10 cm
1,98 cm

Iy =
Wy =
y =
iy =

4,62 cm4
1,49 cm3
3,62 cm
1,19 cm

19,34
5,80
2,55
2,22

51

E 85410 frame

54.5

X
Y

90.3

X
Y

49

E 85400 frame

61.4

E 85 technical catalogue
01.2011

3.9

E 85

curtain wall system


description

sash for
E 85210 projected
window

profile

X
Y

49.5

code

length
weight
ext. perimeter
vis. perimeter

79

X
Y

49.5

E 85211

sash for
parallel
window

79

X
Y

55.3

sash for
E 85200 projected
window

6,01 m
1413 g/m
365 mm
105 mm

Ix =
Wx =
ex =
ix =

30,66 cm4
7,63 cm3
2,81 cm
2,54 cm

Iy =
Wy =
y =
iy =

8,17 cm4
1,99 cm3
4,35 cm
1,31 cm

6,01 m
1416 g/m
357 mm
104 mm

Ix =
Wx =
ex =
ix =

30,90 cm4
7,57 cm3
2,81 cm
2,53 cm

Iy =
Wy =
y =
iy =

8,15 cm4
1,92 cm3
4,44 cm
1,30 cm

6,01 m
934 g/m
287 mm
209 mm

Ix =
Wx =
ex =
ix =

11,78
3,72
3,49
1,84

cm4
cm3
cm
cm

Iy =
Wy =
y =
iy =

6,71 cm4
1,92 cm3
3,17 cm
1,39 cm

E 2308

22

19.7

E 85 technical catalogue
01.2011

6,01 m
208 g/m
99 mm
43 mm

6,01 m
200 g/m
101 mm
46 mm

4.3

operating
rod

19.2

14.8

external
E 85615 glass
support

27.9

57.8

external
E 85614 glass
support

statical values

4,4 m
159 g/m
48 mm
0 mm

3.10

E 85

curtain wall system

E 2309

operating
rod

profile

4.7

description

23.5

E 85915 spacer
19

10.2

6,01 m
435 g/m
151 mm
0 mm

47.6

23.6

pressure
E 85700 plate

pressure
E 85745 plate

E 85 technical catalogue
01.2011

10.2
46.4

5.5

pressure
E 85702 plate for
slope > 15

6,01 m
655 g/m
205 mm
0 mm

47.6

pressure
E 85701 plate for
slope > 25

50

4,40 m
197 g/m
55 mm
0 mm

6,01 m
130 g/m
66 mm
0 mm

4.8

code

length
weight
ext. perimeter
vis. perimeter

6,01 m
403 g/m
138 mm
0 mm

6,01 m
416 g/m
113 mm
54 mm

3.11

statical values

E 85

curtain wall system


code

description

profile

89.8

6,01 m
1204 g/m
349 mm
74 mm

35.9

31.6

pressure
E 85705 plate for
angle 22.5

97

44

pressure
E 85707 plate for
angle 37.5

80.8

6,01 m
1121 g/m
327 mm
63 mm

28.2

pressure
E 85704 plate for
angle 15

pressure
E 85706 plate for
angle 30

70.7

6,01 m
1034 g/m
305 mm
51 mm

25.9

pressure
E 85703 plate for
angle 7.5

110.2

6,01 m
1291 g/m
371 mm
86 mm

6,01 m
1455 g/m
413 mm
106 mm

6,01 m
1620 g/m
455 mm
128 mm

53.8

pressure
E 85708 plate for
angle 45

length
weight
ext. perimeter
vis. perimeter

119.2

E 85 technical catalogue
01.2011

3.12

statical values

E 85

curtain wall system

cover cap
E 85719 for E 85709

pressure
E 85750 plate

cover cap
E 85751 for E 85750

E 85 technical catalogue
01.2011

18.2

6,01 m
508 g/m
169 mm
0 mm

46.2

6,01 m
384 g/m
169 mm
41 mm

50

24.3

6,01 m
126 g/m
87 mm
37 mm

6,01 m
348 g/m
130 mm
42 mm

48

4.9

pressure
E 85709 plate

42.2

12.3

pressure
E 85741 plate for
corner 135

6,01 m
510 g/m
170 mm
0 mm

pressure
E 85740 plate for
corner 90

profile

19.1

description

10.2

code

length
weight
ext. perimeter
vis. perimeter

13.8

6,01 m
54 g/m
45 mm
16 mm

3.13

statical values

E 85

curtain wall system


profile

cover
E 85712 cap

cover
E 85713 cap

20

cover
E 85716 cap

E 85 technical catalogue
01.2011

6,01 m
400 g/m
191 mm
91 mm

30

6,01 m
467 g/m
231 mm
111 mm

60

6,01 m
821 g/m
291 mm
171 mm

50
25

50

cover
E 85715 cap

15

6,01 m
332 g/m
166 mm
81 mm

6,01 m
432 g/m
211 mm
101 mm

50

cover
E 85714 cap

12

6,01 m
289 g/m
144 mm
75 mm

50

cover
cap

50

E 85711

description

50

code

length
weight
ext. perimeter
vis. perimeter

3.14

statical values

E 85

curtain wall system


description

cover
E 85718 cap

profile

50

code

165

25

18

6,01 m
281 g/m
150 mm
77 mm

50

cover
E 85721 cap

50

cover
E 85722 cap

40

50

cover
E 85723 cap

50

100

cover
E 85724 cap

160

E 85 technical catalogue
01.2011

6,01 m
1779 g/m
506 mm
381 mm

6,01 m
467 g/m
206 mm
121 mm

50

cover
E 85720 cap

length
weight
ext. perimeter
vis. perimeter

6,01 m
462 g/m
231 mm
110 mm

6,01 m
1207 g/m
337 mm
216 mm

6,01 m
1627 g/m
453 mm
333 mm

3.15

statical values

E 85

curtain wall system


code

description

profile

50

cover
E 85730 cap

12

cover cap
E 85732 corner 135

49.8

6,01 m
446 g/m
206 mm
79 mm

17.6

45

51

cover cap
E 85790 inox

15

20

X
Y

45.6

transom

E 85906 connector

40

E 85 technical catalogue
01.2011

6,01 m
- g/m
- mm
- mm

6,01 m
- g/m
- mm
- mm

51

cover cap
E 85791 inox

statical values

6,01 m
262 g/m
132 mm
67 mm

6,01 m
373 g/m
171 mm
61 mm

20.4

cover cap
E 85731 corner 90

length
weight
ext. perimeter
vis. perimeter

6,01 m
724 g/m
251 mm
0 mm

3.16

Ix =
Wx =
ex =
ix =

3,93 cm4
1,39 cm3
2,30 cm
1,21 cm

Iy =
Wy =
y =
iy =

8,95
3,90
2,83
1,83

cm4
cm3
cm
cm

E 85

curtain wall system


code

description

length
weight
ext. perimeter
vis. perimeter

profile

X
Y

45.6

transom

E 85907 connector

45.7

X
Y

42.6

base for
E 85908 transom
connector

6.5

transom

45

E 85994 connector

43.2

insert

45.2

E 85951 for E 85101

38.2

45.2

insert

E 85952 for E 85102

58.2

45.2

insert

E 85953 for E 85103

78.2

E 85 technical catalogue
01.2011

statical values

cm4
cm3
cm
cm

6,01 m
1010 g/m
187 mm
0 mm

Ix =
Wx =
ex =
ix =

9,79
4,20
2,28
1,62

cm4
cm3
cm
cm

Iy =
Wy =
y =
iy =

6,01 m
367 g/m
109 mm
0 mm

Ix =
Wx =
ex =
ix =

0,04 cm4
0,08 cm3
2,13 cm
0,16 cm

Iy =
Wy =
y =
iy =

2,02 cm4
0,95 cm3
0,44 cm
1,22 cm

2,01 m
1557 g/m
261 mm
0 mm

Ix =
Wx =
ex =
ix =

10,31 cm4
4,25 cm3
2,25 cm
1,34 cm

Iy =
Wy =
y =
iy =

12,85 cm4
5,71 cm3
2,43 cm
1,49 cm

2,01 m
1739 g/m
240 mm
0 mm

Ix =
Wx =
ex =
ix =

9,82
4,96
2,26
1,24

cm4
cm3
cm
cm

Iy =
Wy =
y =
iy =

11,31 cm4
5,01 cm3
1,98 cm
1,33 cm

2,01 m
2041 g/m
280 mm
0 mm

Ix =
Wx =
ex =
ix =

31,32 cm4
10,71 cm3
2,26 cm
2,04 cm

Iy =
Wy =
y =
iy =

13,91 cm4
6,15 cm3
2,92 cm
1,36 cm

2,01 m
2344 g/m
320 mm
0 mm

Ix =
Wx =
ex =
ix =

67,86
17,02
2,26
2,80

cm4
cm3
cm
cm

Iy =
Wy =
y =
iy =

16,05
7,30
3,99
1,38

3.17

10,20
4,47
2,33
1,65

cm4
cm3
cm
cm

E 85

curtain wall system


code

description

length
weight
ext. perimeter
vis. perimeter

profile

insert

45.2

E 85954 for E 85104

98.2

insert

45.2

E 85955 for E 85105

128.2

44.2

insert

E 85956 for E 85106

143.7

43.6

insert

E 85957 for E 85107

163.7

43.2

insert

E 85958 for E 85108

154.7

E 85 technical catalogue
01.2011

X
Y

43.2

insert for
E 85961 polygonal
atriums

90

statical values

2,01 m
2646 g/m
360 mm
0 mm

Ix =
Wx =
ex =
ix =

121,71 cm4
24,17 cm3
2,26 cm
3,52 cm

Iy =
Wy =
y =
iy =

19,10 cm4
8,45 cm3
5,04 cm
1,40 cm

2,01 m
3100 g/m
420 mm
0 mm

Ix = 239,90 cm4
Wx = 36,40 cm3
ex =
2,26 cm
ix =
4,57 cm

Iy =
Wy =
y =
iy =

22,99 cm4
10,17 cm3
6,59 cm
1,42 cm

2,01 m
3275 g/m
449 mm
0 mm

Ix =
Wx =
ex =
ix =

311,58 cm4
42,32 cm3
2,21 cm
5,07 cm

Iy =
Wy =
y =
iy =

23,06
10,43
7,36
1,38

2,01 m
3532 g/m
488 mm
0 mm

Ix = 425,36 cm4
Wx = 50,82 cm3
ex =
2,18 cm
ix =
5,70 cm

Iy =
Wy =
y =
iy =

24,21 cm4
11,11 cm3
8,37 cm
1,36 cm

2,01 m
3499 g/m
469 mm
0 mm

Ix = 368,85 cm4
Wx = 46,79 cm3
ex =
2,16 cm
ix =
5,34 cm

Iy =
Wy =
y =
iy =

23,17 cm4
10,73 cm3
7,88 cm
1,34 cm

2,01 m
3977 g/m
255 mm
0 mm

Ix = 138,19 cm4
Wx = 30,46 cm3
ex =
2,16 cm
ix =
3,06 cm

Iy =
Wy =
y =
iy =

39,69
18,38
4,54
1,64

3.18

cm4
cm3
cm
cm

cm4
cm3
cm
cm

E 85

curtain wall system


code

description

length
weight
ext. perimeter
vis. perimeter

profile

roof
connector/
E 85969 insert for
E 85109

40.8

181.7

X
Y

45.2

E 85960 roof
connector

15.5

216

insert

E 85972 for E 85152

15.5

insert

insert

E 85975 for E 85155

E 85 technical catalogue
01.2011

15.5

51.9

71.9

15.5

insert

31.9

E 85973 for E 85153

E 85974 for E 85154

101.9

statical values

60,25 cm4
32,79 cm3
9,17 cm
1,45 cm

2,01 m
7680 g/m
545 mm
0 mm

Ix = 1076,08 cm4
Wx = 117,52 cm3
ex =
2,04 cm
ix =
5,80 cm

Iy =
Wy =
y =
iy =

2,01 m
10916 g/m
624 mm
0 mm

Ix = 1908,80 cm4
Wx = 175,48 cm3
ex =
2,26 cm
ix =
6,87 cm

Iy = 108,21 cm4
Wy = 47,88 cm3
y = 10,88 cm
iy =
1,64 cm

2,01 m
764 g/m
93 mm
0 mm

Ix =
Wx =
ex =
ix =

3,26
2,04
0,78
1,07

cm4
cm3
cm
cm

Iy =
Wy =
y =
iy =

0,81 cm4
1,04 cm3
1,60 cm
0,54 cm

2,01 m
1034 g/m
133 mm
0 mm

Ix =
Wx =
ex =
ix =

11,95
4,60
0,78
1,77

cm4
cm3
cm
cm

Iy =
Wy =
y =
iy =

1,24
1,59
2,60
0,57

cm4
cm3
cm
cm

2,01 m
1304 g/m
173 mm
0 mm

Ix =
Wx =
ex =
ix =

28,29
7,87
0,78
2,42

cm4
cm3
cm
cm

Iy =
Wy =
y =
iy =

1,67
2,14
3,60
0,59

cm4
cm3
cm
cm

2,01 m
1709 g/m
233 mm
0 mm

Ix =
Wx =
ex =
ix =

71,55
14,04
0,78
3,36

cm4
cm3
cm
cm

Iy =
Wy =
y =
iy =

2,31 cm4
2,97 cm3
5,10 cm
0,60 cm

3.19

E 85

curtain wall system

E 85640 spacer 6 mm

profile

description

8.7

code

10

E 8611

12.7

10

spacer 10 mm

12
10

20.7

E 85641 spacer 12 mm

14.7

10

E 85 technical catalogue
01.2011

9.9

10

6.2

E 85651 spacer 15

10

11.3

E 85650 spacer 7,5

18

E 85642 spacer 18 mm

10

length
weight
ext. perimeter
vis. perimeter

6,01 m
97 g/m
59 mm
6 mm

6,01 m
130 g/m
82 mm
10 mm

6,01 m
140 g/m
90 mm
12 mm

6,01 m
200 g/m
98 mm
18 mm

6,01 m
101 g/m
61 mm
6 mm

6,01 m
108 g/m
65 mm
6 mm

3.20

statical values

E 85

curtain wall system

E 85653 spacer 30

E 85 technical catalogue
01.2011

8.5

19.8

10

E 85655 spacer 45

10

9.3

33 879

7.5

16.8

10

E 85654 spacer 37,5

spacer for
structural
glazing

6.9

10

14.6

E 85652 spacer 22,5

profile

6.5

description

12.8

code

11

length
weight
ext. perimeter
vis. perimeter

6,01 m
117 g/m
69 mm
7 mm

6,01 m
128 g/m
75 mm
7 mm

6,01 m
142 g/m
82 mm
8 mm

6,01 m
161 g/m
93 mm
9 mm

6,01 m
70 g/m
53 mm
0 mm

3.21

statical values

E 85

curtain wall system


code

description

profile

19.3

E 85920 glazing clip

8.9

33 881

glazing clip
for 33 879

16

22

8.6

33 501

spacer for
structural
glazing

24

spacer for
E 85990 structural
glazing

glazing
E 85902 support

E 85 technical catalogue
01.2011

43.6

17.2

E 85921 glazing clip

10

43.6

44.9

length
weight
ext. perimeter
vis. perimeter

6,01 m
229 g/m
138 mm
0 mm

6,01 m
139 g/m
71 mm
0 mm

6,01 m
307 g/m
68 mm
0 mm

6,01 m
596 g/m
110 mm
0 mm

6,01 m
602 g/m
115 mm
0 mm

6,01 m
383 g/m
122 mm
0 mm

3.22

statical values

E 85

curtain wall system


description

profile

48.9

6,01 m
408 g/m
130 mm
0 mm

54.9

6,01 m
446 g/m
142 mm
0 mm

29.8

2,01 m
246 g/m
79 mm
0 mm

17.2

code

length
weight
ext. perimeter
vis. perimeter

17.2

glazing
E 85916 support

9.7

glazing
E 85910 support

6,01 m
266 g/m
86 mm
0 mm

9.7

glazing
E 85912 support

glazing
E 85917 support

33.3

2,01 m
306 g/m
99 mm
0 mm

9.7

glazing
E 85914 support

statical values

39.8

fixing

E 85992 bracket

106

6,01 m
6468 g/m
776 mm
0 mm

158

E 85 technical catalogue
01.2011

3.23

Ix = 348,56 cm4
Wx = 44,06 cm3
ex =
7,76 cm
ix =
3,81 cm

Iy = 254,56 cm4
Wy = 32,82 cm3
y =
7,90 cm
iy =
3,26 cm

E 85

curtain wall system


code

description

length
weight
ext. perimeter
vis. perimeter

profile

statical values

fixing

E 85900 bracket

105

2,01 m
8397 g/m
871 mm
0 mm

Ix = 822,14 cm4
Wx = 74,74 cm3
ex =
8,00 cm
ix =
5,14 cm

Iy = 279,77 cm4
Wy = 37,20 cm3
y =
11,00 cm
iy =
3,09 cm

6,01 m
10260 g/m
1032 mm
0 mm

Ix = 836,65 cm4
Wx = 79,68 cm3
ex = 10,76 cm
ix =
4,69 cm

Iy = 842,12 cm4
Wy = 78,27 cm3
y = 10,50 cm
iy =
4,71 cm

2,01 m
10972 g/m
693 mm
0 mm

Ix = 907,18 cm4
Wx = 86,40 cm3
ex = 10,23 cm
ix =
4,73 cm

Iy = 771,28 cm4
Wy = 75,39 cm3
y = 10,50 cm
iy =
4,36 cm

2,01 m
4892 g/m
494 mm
0 mm

Ix = 234,00 cm4
Wx = 31,20 cm3
ex =
7,89 cm
ix =
3,59 cm

Iy = 152,96 cm4
Wy = 19,39 cm3
y =
7,50 cm
iy =
2,91 cm

2,01 m
3458 g/m
415 mm
0 mm

Ix =
Wx =
ex =
ix =

cm4
cm3
cm
cm

Iy = 135,56 cm4
Wy = 17,89 cm3
y =
6,13 cm
iy =
3,25 cm

220

fixing

E 85993 bracket

150

210

fixing

E 85918 bracket

140

210

fixing

E 85913 bracket

100

150

fixing

E 85967 bracket

105

suppl.
profile for
E 85901 fixing
bracket
E 85 technical catalogue
01.2011

84

26

6,01 m
313 g/m
65 mm
0 mm

3.24

85,63
13,96
7,58
2,59

E 85

curtain wall system


description

suppl.
profie for
E 85903 fixing
bracket

profile

14.3

code

length
weight
ext. perimeter
vis. perimeter

108

insert
for E 85130

60

7528

6,01 m
2036 g/m
271 mm
0 mm

5,00 m
1847 g/m
239 mm
0 mm

44.2

60

suppl.
E 85966 profile for
louvers

29.6

40.3

E 85911

drainage
profile

17.5

spacer for
E 85290 etalbond

E 85 technical catalogue
01.2011

6,01 m
1246 g/m
207 mm
0 mm

6,01 m
240 g/m
122 mm
0 mm

21.1

6,01 m
448 g/m
126 mm
0 mm

13.8

15.3

6,01 m
283 g/m
46 mm
0 mm

23

profile
E 85904 for spring
connector

statical values

3.25

Ix =
Wx =
ex =
ix =

37,13 cm4
12,38 cm3
3,00 cm
2,33 cm

Iy =
Wy =
y =
iy =

37,13 cm4
12,38 cm3
3,00 cm
2,33 cm

E 85

curtain wall system


description

profile

19

code

spacer for
E 85291 etalbond

25.1

wall
E 85620 attachment
profile

24.5

43

6,01 m
381 g/m
170 mm
0 mm

40

74

E 85 technical catalogue
01.2011

6,01m
176 g/m
65 mm
0 mm

43

70

wall
E 85621 attachment
profile

6,01 m
400 g/m
134 mm
0 mm

6,01 m
346 g/m
176 mm
0 mm

24.5

suppl. profile
E 85612 for sealing
membrane

29.6

40

E 85611

suppl. profile
for sealing
membrane

7.5

suppl. profile
E 85610 for sealing
membrane

length
weight
ext. perimeter
vis. perimeter

6,01 m
984 g/m
277 mm
0 mm

6,01 m
999 g/m
285 mm
0 mm

3.26

statical values

E 85

curtain wall system


code

description

profile

25

60

E 8700

cover cap
anti-burglar

23

E 8620

pressure plate
anti-burglar

47001

9.6
10

flat bar
anti-burglar

57.6

50

square tube
anti-burglar

45

50009

60

E 8701

cover cap
anti-burglar

47.5

6,01 m
460 g/m
223 mm
107 mm

6,01 m
554 g/m
168 mm
0 mm

6,01 m
1350 g/m
120 mm
0 mm

6,01 m
1816 g/m
182 mm
0 mm

100

E 85 technical catalogue
01.2011

statical values

6,01 m
479 g/m
231 mm
111 mm

6,01 m
1312 g/m
388 mm
251 mm

50

cover
E 85727 cap

length
weight
ext. perimeter
vis. perimeter

3.27

Ix =
Wx =
ex =
ix =

21,00
8,84
2,25
1,77

cm4
cm3
cm
cm

Iy =
Wy =
y =
iy =

19,23
8,55
2,38
1,69

cm4
cm3
cm
cm

PROFILES
DRAWINGS

SCALE 1:1

E 85

curtain wall system


description

reinforcement
E 85801 for transom
E 85306

profile

X
Y

45.4

code

length
weight
ext. perimeter
vis. perimeter

111

X
Y

45.4

reinforcement
E 85802 for transom
E 85357

156

44.4

51.5

X
Y

36

reinforcement
E 85805 additional

6.4

60

E 85 technical catalogue
01.2011

6,01 m
2356 g/m
355 mm
0 mm

Ix = 127,94 cm4
Wx = 21,57 cm3
ex =
2,27 cm
ix =
3,83 cm

Iy =
Wy =
y =
iy =

28,07
12,36
5,93
1,79

cm4
cm3
cm
cm

6,01 m
2964 g/m
445 mm
0 mm

Ix = 310,45 cm4
Wx = 37,33 cm3
ex =
2,27 cm
ix =
5,32 cm

Iy =
Wy =
y =
iy =

37,86
16,68
8,32
1,86

cm4
cm3
cm
cm

6,01 m
1250 g/m
276 mm
0 mm

Ix =
Wx =
ex =
ix =

12,08
4,45
2,22
1,62

cm4
cm3
cm
cm

Iy =
Wy =
y =
iy =

3,44 cm4
1,55 cm3
2,72 cm
0,86 cm

6,01 m
889 g/m
165 mm
0 mm

Ix =
Wx =
ex =
ix =

3,50
1,89
1,38
1,03

cm4
cm3
cm
cm

Iy =
Wy =
y =
iy =

1,18 cm4
0,86 cm3
1,84 cm
0,60 cm

Ix =
Wx =
ex =
ix =

26,27
7,76
2,28
1,78

cm4
cm3
cm
cm

Iy =
Wy =
y =
iy =

6,01 m
210 g/m
44 mm
0 mm

45.6

reinforced
E 85905 transom
connector

27.6

reinforced
glazing support
E 85804 for 3rd level
transom

15.6

reinforced
glazing support
E 85803 for 2nd level
transom

statical values

6,01 m
2232 g/m
321 mm
0 mm

3.28

24,34
10,68
3,89
1,72

cm4
cm3
cm
cm

E 85

curtain wall system

mullions, inserts, connectors and flush transoms 2nd and 3rd level
code
E
E
E
E
E
E
E
E
E
E

85100
85101
85102
85103
85104
85105
85106
85107
85108
85109

E 85 technical catalogue
01.2011

insert

E
E
E
E
E
E
E
E
E

85951
85952
85953
85954
85955
85956
85957
85958
85969

roof
connector
E
E
E
E
E
E
E
E
E
E

85960
85960
85960
85960
85960
85960
85969
85969
85969
85969

2nd level
flush
transom

2nd level flush


transom + suppl.
Profile

3rd level
flush
transom

E 85302
E 85303
E 85304
E 85305
E 85306
E 85307
-

E 85300+E
E 85300+E
E 85300+E
E 85300+E
-

E
E
E
E
E
E
E
E
E
E

4.1

85600
85601
85602
85603

85352
85353
85354
85355
85356
85357
85358
85359
85359
85369

3rd level flush hidden


transom + suppl.
profile
E 85380+E
E 85380+E
E 85380+E
E 85380+E
-

85600
85601
85602
85603

E85

curtain wall system


5

144.5

194

10

20

2.5

10

24.5

2.8

mullions

10

50

44.4

45
16

E 85106

E 85107

180

200

196

216

2.5

66

24.5

2.8

2.5

10

10

10

insert E 85957

10

10

20

20

16

20

50
10

50
10

insert E 85956

155.5

12

20

19

10

50

24.5

10

E 85100

10
20

59

16

200
216

E 85102

E 85108

10

insert E 85952
106
90

50

50
10

39

E 85101

86
70

insert E 85951

44

insert E 85958

79

E 85103

24.5

182.5

15

10

126
110

insert E 85953

20

99

insert E 85969

10

E 85104

20

129

E 85109

10

E 85105

scale 1:1
E 85 technical catalogue
01.2011

46

176
160

10

insert E 85955

16

230
246

50

4.2

50

50
10

42

146
130

insert E 85954

E 85

curtain wall system

split mullions, inserts and flush transoms 2nd and 3rd level
code
E
E
E
E

E 85 technical catalogue
01.2011

85152
85153
85154
85155

insert
E
E
E
E

85972
85973
85974
85975

2nd level
flush
transom

2nd level flush


transom + suppl.
Profile

3rd level
flush
transom

E 85304
E 85305
E 85306
E 85307

E 85300+E 85601
E 85300+E 85602
E 85300+E 85603
-

E
E
E
E

4.3

85354
85355
85356
85357

3rd level flush hidden


transom + suppl.
profile
E 85380+E 85601
E 85380+E 85602
E 85380+E 85603
-

E 85

curtain wall system


split mullions

supplementary profiles for split mullions

suppl. profile E 85150

90

45.8

68.8

E 85150

32

32.7

16.3
insert E 85972

52.7

insert E 85974

E 85154

110

E 85153

130

insert E 85973

72.7

E 85152

mullionE85155

suppl. profile E 85151

13.5

160

E 85155

102.7

insert E 85975

E 85151
22.5

32

scale 1:1
E 85 technical catalogue
01.2011

4.4

mullionE85155

E 85

curtain wall system


mullion for substructure & cover cap

50

E 85120

20

16

10

10
10

20
10

10
E 85350
mullion E 85120

E 85360

2.5

E 85301/E 85351

27.7

26.4

E 85302/E 85352

38

65

81

35.3

24.5

E 85300

cover cap E 19641

19.5

11

19.5

7.5

appropriate transom 2nd and 3rd level


code

2nd level
transom

3rd level transom

E 85120

E 85300
E 85301
E 85302

E 85350/E 85360
E 85351
E 85352

scale 1:1
E 85 technical catalogue
01.2011

4.5

E 19641

E 85

curtain wall system


mullion 90

10

10

10

10

10

15.5

10

10

15.5

40.5

24.5

10

2.5

60.5

E 85130

10

2.5

15.5
10
20

10

10

60.5

2.5

10

10

90

106

15.5

2.5

24.5

40.5

16

20

90

16
106
insert 7528

insert and flush transoms 2nd and 3rd level


code

insert

2nd level
flush
transom

E 85130

7528

E 85304

2nd level flush


transom + suppl.
profile

3rd level
flush
transom

3rd level flush hidden


transom + suppl.
Profile

E 85300+E85601

E 85354

E 85380+E 85601

scale 1:1
E 85 technical catalogue
01.2011

4.6

E 85

curtain wall system


mullion 135
cover cap E 85732
pressure plate E 85741

16

24

10

10

90

118

45

6 0 .8

insert E 85973

E 85135
135
76.9

22.5

7 6 .9

142.1

insert and flush transoms 2nd and 3rd level

scale 1:1
E 85 technical catalogue
01.2011

code

insert

2nd level
flush
transom

E 85135

E 85973

E 85304

2nd level flush


transom + suppl.
Profile

3rd level
flush
transom

3rd level flush hidden


transom + suppl.
profile

E 85300+E85601

E 85354

E 85380+E 85601

4.7

119.7

1 6 .3

E 85

curtain wall system


supplementary mullion profile
30-90

40.1

splitrotatingmullion

E 85140

50
any mullion

split rotating mullion with E 85140


30
20

36

16

10

19.6

23.3

55.6

26.5

E 85141

Appropriate transoms 2nd and 3rd level for E 85141

scale 1:1
E 85 technical catalogue
01.2011

code

2nd level transom

3rd level transom

E 85141

E 85300

E 85350/E 85360

4.8

E 85

curtain wall system


inner supplementary mullion profile 90

pressure plate E 85740


cover cap E 85731

19.8

3.3

90

14.9

48.2

48

10.2

any mullion

3.3

14.9

E 85142
19.8

10.2

48.2

any mullion

scale 1:1
E 85 technical catalogue
01.2011

4.9

E 85

curtain wall system


outer supplementary mullion profile 90

cover cap E 85713


pressure plate E 85700

26.3
31.3

E 85143

35.7

31.3
26.3

4.4

35.7

.3
44

4.4

pressure plate E 85700


spacer E 85655
any mullion

scale 1:1
E 85 technical catalogue
01.2011

4.10

cover cap E 85713

E 85

curtain wall system

flush transoms 2nd and 3rd level

E 85 technical catalogue
01.2011

code

3rd level
flush
transom

2nd level flush


transom + suppl.
profile

E 85300
E 85301
E 85302
E 85303
E 85304
E 85305
E 85306
E 85307

E 85351
E 85352
E 85353
E 85354
E 85355
E 85356
E 85357

E 85300+E
E 85300+E
E 85300+E
E 85300+E
-

4.11

85600
85601
85602
85603

3rd level flush hidden


transom + suppl.
profile

E
E
E
E

85380+E
85380+E
85380+E
85380+E
-

85600
85601
85602
85603

E85

curtain wall system

2nd level transoms

2nd level transom


2.5
12.5

32.2

1.8

52

72

92

112

142

10

23.5

20

10

50

47

16

15

16

29

31

45

3rd level transom

E 85302
1.5

10

E 85301

E 85303

E 85304

E 85305

E 85306

E 85307

49

69

89

109

129

159

65

85

105

125

145

175

20
10

20

10

10

50

10

1
7

46

10
10

20
10

50

1.8
12.2

1.5

E 85300

13

3rd level transoms


E 85360

27

47

67

87

107

127

157

177

197

226 3

11

50

46

20

23.5

11

E 85351

10

16

15
25

scale 1:1
4.12

E 85352

E 85353

E 85354

E 85355

E 85356

E 85357

E 85358

E 85359

E 85369

35

55

75

95

115

135

165

185

205

235

45

65

85

105

125

145

175

195

215

245

20
10

E 85 technical catalogue
01.2011

1
7

10

50
11

20

10

50

20

11

E 85350

E 85

curtain wall system


2nd level supplementary transoms
2.5

15.2

49.5

1.8

69.5

1.8

89.5

1.8

109.5

1.8

1.4
58

55.2

55

58

1.5

transom E 85300

1.5

E 85600
69

3rd level hidden transom


2

46

28

50

11

E 85380

50

13.2

11

21.2

scale 1:1
E 85 technical catalogue
01.2011

4.13

E 85601

E 85602

E 85603

89

109

129

1.4

15.2

E 85

curtain wall system


3rd level split transom for conservatory
transom E 85370
suppl. profile E 85670

30-9

27.5

40

10

10

11

E 85370

55

10
65

supplementary profile for E 85370

2nd level split transom for conservatory


transom E 85320

51

30-9

10

20

10

32

42

10

68.9

13.2

E 85670

29

16
45

scale 1:1
E 85 technical catalogue
01.2011

12

E 85320

4.14

E 85

curtain wall system


frame for thermo-break projected and parallel opening windows

54.5

38.5

extruded al. joint corner bracket 54 457 or 53 302

RAL 9005

16

E 85410

60

30.3
90.3

appropriate transom 2nd and 3rd level for frame

operating rods
19.7

E 85410

E
E
E
E
E

85303
85304
85305
85306
85307
-

3rd level transom


4.3

2nd level transom

E 85353
E 85354
E 85355
E 85356
E 85357
E 85358
E 85359
E 85369

E 2308

23.5
4.7

code

E 2309

note: frame E 85410 is suitable for


sashes E 85210 and E 85211

spacer

4.8

19

scale 1:1
E 85 technical catalogue
01.2011

4.15

E 85915

E 85

curtain wall system


sash for thermo-break projected window

extruded al. joint corner bracket 54 461


79
22.1

20

E 85210

sash E 85210
30.6

13
16.5

extruded al. joint corner bracket 54 462

19.2
12.8
6.4

RAL 9005

23

20

17.1

7.9
21.5

11

4.4

E 85614

27.9

49.5

external glass support


for structural glazing

18.9

56.9

glass support E 85615

sash for thermo-break parallel opening window


extruded al. joint corner bracket 54 461
79
22.1

20

E 85211
12

sash E 85210
RAL 9005

13.5

23.4

13.7

7.9

glass support E 85615

23

15

E 85615
11

11.2
22

scale 1:1
E 85 technical catalogue
01.2011

17.5

extruded al. joint corner bracket 54 462

4.6

30.6

49.5

external glass support


for cover cap

18.9

56.9

4.16

9.2
1.6

E 85

curtain wall system


sash profile for projected window

extruded al. joint corner bracket 54 457 or 53 302


57.8

17

extruded al. joint corner bracket 54 459

16.5

E 85200

16

55.3

22.8

40.8

33.6

24.2

frame for projected window


61.4
22.5

32

49

17

38.9

E 85400

extruded al. joint corner bracket 54 458


extruded al. joint corner bracket 54 457 or 53 302

scale 1:1
E 85 technical catalogue
01.2011

4.17

E85

curtain wall system


pressure plates

5
26.

E 85703

30

25.9

7.5

10.2

E 85700

E 85706
35.9

10.5

14

47.6
70.7
165

120
97

E 85707

15
14

46.4

44

E 85704

.9
36

28.2

7.4

10.2

15.8

37.5

E 85701

14

80.8

105

150

110.2

E 85708

10.2

53.8

31.6
14

E 85745

23.6

13.4

45

22.5

47
.2

E 85705

2 1 .2

41.6

135
89.8
90

47.6
14

119.2

scale 1:1
E 85 technical catalogue
01.2011

4.18

E 85

curtain wall system

10.5

E 85721

18

7.5

cover caps

50

40

25

1.3

15

E 85722

50

100

69

160

129

1.4

E 85723

31

1.4

16.3

47.4

50

E 85724
47.4

1.4

50

scale 1:1
E 85 technical catalogue
01.2011

31

1.4

4.19

E85

curtain wall system


cover caps
47

E 85716

13.8

E 85718

E 85751

28.9

12

4.9

E 85711

14.4

10.2

47.4

E 85712

48

15

1.5

16.8

E 85750

45.4

16.3

47.4

16.8

60

50

50

12.5

25

165

E 85719

12.5

10.5

12.3
7.2 5.1

20

E 85727

50

E 85709
17.4

15.2
50

17.4

E 85714

70.4

25

11.3

47.4

7.1

E 85713

6.3

47.4

50

24.3
10

5.9

7.1

12

E 85730

100

50

50
50

E 85715

47.4

E 85720

E 85702
5.5

25

30

1.5

16.3

16.3

47.4

47.4
50

50

scale 1:1
E 85 technical catalogue
01.2011

50

50

4.20

E 85

curtain wall system


cover caps & pressure plates
cover cap E 85731
30
12

18

cover cap E 85732

E 85741
30

18

E 85740

22.5

12

1 3 .5

1 3 .5

.2
42

90

46.2

45

32
21.2

10.8
31.5

E 85732

45

22.5

21.2

2 0 .6

2 0 .6

32

10.8

E 85731

90

50
pressure plate E 85740

45

pressure plate E 85741

E 85791 inox

15

20

E 85790 inox

51

51

note: cover caps E 85790 and E 85791 have to be used with special pressure plate!
scale 1:1
E 85 technical catalogue
01.2011

4.21

E 85

curtain wall system


spacers for structural glazing

E 85990

14.8

14.8

24

9.2

6.8

19.3

glazing clips
43.6

43.6

10
15.3

13

E 85903

8.6

E 85920

15.3

15.3

13

15.3

spacers for structural glazing


16

33 501

33 879

glazing clip for 33 879

8.9
4

22

33 881
10

12

scale 1:1
E 85 technical catalogue
01.2011

7.3

9.3

11

4.22

E 85

curtain wall system


transom connectors

45.6

45.6

transom connector E 85908

E 85906

E 85907

40

45.7

base for transom connectors

42.6

25
10

45

10

4
5

transom connector E 85907

E 85908

E 85994
43.2

6.5

reinforced transom connector


60

profile for spring connector

13.8

45.6

15.3
1.5
13.8

E 85905

E 85904

scale 1:1
E 85 technical catalogue
01.2011

4.23

E 85

curtain wall system


inserts

12.6

45.2

4
6.

mullionE85101

E 85952

38.4

E 85953

58.4

mullionE85102

7.2

mullionE85104

7.2

128.2

E 85956
mullionE85105
7.2

20

E 85955

45.2

44.2

scale 1:1
E 85 technical catalogue
01.2011

123.9

mullionE85103

mullionE85106

108.4

98.2

E 85954

78.4

7.2

78.2

143.7

7.2

58.2

7.2

E 85951

18.4

38.2

12.6

4
6.

4.24

E 85

curtain wall system

12.6

12.6

inserts

4
6.

4
6.

20

134.9

154.7

143.9

163.7

20

E 85958
E 85957
7.2

7.2

mullionE85107

scale 1:1
E 85 technical catalogue
01.2011

43.6

43.2

4.25

mullionE85108

E 85

curtain wall system


roof connectors / insert for E 85109
28.8

8.2

8.2

8.2

28.4

6.2

8.2

6.2

149.1

181.7

216

183.4

mullionE85109

E 85960

E 85969

29.2

14.4

scale 1:1
E 85 technical catalogue
01.2011

7.2

8.4

7.2

7.4

8.4

14.4

7.4

28.8

45.2

40.8

4.26

E 85

curtain wall system

6.8

inserts for half mullions

18.3

31.9

6.4

mullionE85152
6.8

38.3

51.9

E 85972

mullionE85153
6.8

58.3

71.9

E 85973

mullionE85154
6.8

mullionE85155

88.3

101.9

E 85974

6.8

E 85975

15.5

scale 1:1
E 85 technical catalogue
01.2011

4.27

E 85

curtain wall system


reinforcement for transoms

E 85802

111

156

E 85801

transom E 85357

transom E 85306

45.4

45.4

for transom E 85306 only!

scale 1:1
E 85 technical catalogue
01.2011

4.28

for transom E 85357 only!

E 85

curtain wall system

10

10

6.5

22.5

12

10.1

10

E 85641

E 85652

10

6.9

11.9

18

30

E 85642

10

E 85653

10

supplementary profile for louvers

drainage profile

29.6

11.4

6.1

15.6

17.5

10.4

9.6

E 85966

scale 1:1
E 85 technical catalogue
01.2011

4.29

15.3

15.5

7.2

23

24.4

R3

9.6

E 85911
23.9

44.2

40.3

32

15.8

0.9

E 85655

17.1

E 85651

45

6.2

8.6

15

10
10

E 85654

10

10

E 8611

7.5

14.1

37.5

E 85650

8.5

6
10

7.5

E 85640

7.2

spacers

E 85

curtain wall system


2nd level glazing supports

3rd level glazing supports

44.9
38.6

6.3

3.3

17.2

a = 32
9.7

E 85902

29.8
a = 26.5

E 85912

48.9
6.3

42.6

3.3

17.2

a = 36
9.7

E 85916

33.3
a = 30

E 85917

54.9
6.3

48.6

17.2

39.8

3.3

a = 42
9.7

E 85910

a = 36.5

E 85914

51.5
36

15.6

15.6

27.6

E 85804

44.4

E 85803

2nd level reinforced


glazing support

3rd level reinforced


glazing support

code

scale 1:1
E 85 technical catalogue
01.2011

E
E
E
E
E
E

85902
85916
85910
85912
85917
85914

accsessory utility lenght loadbearing


capacity
code
a
071
071
071
071
071
071

182
184
183
180
185
181

32 mm
36 mm
41 mm
26,5 mm
30 mm
36,5 mm

1530 N
1200 N
650 N
1175 N
910 N
740 N

4.30

15.6

E 85805

6.4

E 85

curtain wall system


wall attachment profiles

supplementary profile for holding


sealing membrane

46

28
150

60

E 85610

2.5

40

37.5

7.5

20
10.6

20.8
29.6

E 85621

13.5

10

74

46

11

14.5

24.5

E 85611

24

38

37.5

33

10
13.5

E 85612

24.5

E 85620

11

14.5

2.5

10

40

43

70
5

38
43

spacers for etalbond structural glazing

E 85291
25.1

E 85290
21.1

12

12.1
7

scale 1:1
E 85 technical catalogue
01.2011

4.31

15
19

11.4

19

5.7

23
18.7

9.3

5.7

COVER CAP
SECTIONS

DETAILS

E 85

curtain wall system


mullion with 2nd level transom

50

15

10

10

15

tappingscrew
DIN7981 ST5.5x45-C-H
cover cap E 85713

20

15

butyl seal 133 553


gasket130500

16
10

min 6

28
10

6 5

25

pressureplateE85700

gasket 130 470


thermalinsulationspacer80172
gasket 76 651

190

flange 76 674
5

tappingscrew
DIN7981 ST4.8x19-C-H

89

3
130

15
18

10

10
20

15

18
fixing part 71 113

transom E 85304
6
41

mullionE85104

E85CP5.1

50

scale 3/4
E 85 technical catalogue
01.2011

5.1

E 85

curtain wall system


transom 2nd level drainage

covercapE85712
pressureplateE85700
gasket130500
butyl seal 133 553

56.3

50
15

10

50

10

15

min 6

tappingscrew
DIN7981 ST5.5x45-C-H
gasket 130 470
flange 76 674

fixingpart71113
transomE85304
gasket 76 651 behind
thermalinsulationspacer80172
glazing shim 71 183
PVCspacer9020
15
25

5 6

16
28

10
10

89
mullion E 85104

41
130

note:
1. in case of 2nd level drainage, it is obligatory to use 150 mm butyl seal tape in both directions of the cross zone. see detail E85M8.29 / 8.29
2. in case of roof constructions, conservatories, facades with inclinations and polygonal facades with 2nd level drainage, it is obligatory to use
butyl seal tape in both directions.

scale 3/4
E 85 technical catalogue
01.2011

5.2

E85CP5.2

E 85

curtain wall system


transom 2nd level drainage with supplementary transom

covercapE85712
pressureplateE85700
gasket130500
butyl seal 133 553
tappingscrew
DIN7981 ST5.5x45-C-H
min 6

gasket 130 470

58
5

10

50

10

15

tappingscrew
DIN7981 ST4.8x19-C-H

15

tappingscrew
DIN7981 ST4.8x19-C-H
transom profile E 85602
transomE85300
EPDM flange 76 653
thermalinsulationspacer80172
glazing shim 71 184
PVCspacer9020
15
25

5 6

16
28

10
10

109
mullion E 85104

21
130

note:
1. in case of 2nd level drainage, it is obligatory to use 150 mm butyl seal tape in both directions of the cross zone. see detail E85M8.29 / 8.29
2. in case of roof constructions, conservatories, facades with inclinations and polygonal facades with 2nd level drainage, it is obligatory to use
butyl seal tape in both directions.

scale 3/4
E 85 technical catalogue
01.2011

5.3

E85CP5.3

E 85

curtain wall system


transom 3rd level drainage

cover cap E 85712


pressureplateE85700
gasket130500
butyl seal 133 553
tappingscrew
DIN7981 ST5.5x45-C-H
gasket 130 474

56.3

50
15

10

50

10

15

glazing shim 71 185

flange 76 664
fixing part 71 113
transomE85354
silicone flange 76 680 behind
thermalinsulationspacer80172
PVCspacer9020
mullion E 85104
15
25

28
6

16

4
6

10

130

note:
in case of 3rd level drainage, it is obligatory to use butyl seal tape in both directions.

scale 3/4
E 85 technical catalogue
01.2011

41

95

5.4

E85CP5.4

E 85

curtain wall system


projected thermo-break window

gasket 130 706

50

gasket130457

33

glass support E 85615

14.4

14.2
45.8

10.8

10

15

cover cap E 85713


pressureplateE85700
gasket130500

gasket 130 131

25

structural seal 6 mm

28

6
16

31

16
6

butyl seal 133 533

6
7

10

16

28
7

norton tape 6x6.4 mm

gasket 130 176

gasket 130 470

56

sash E 85210
spacer 700R
gasket 130 461

thermalinsulationspacer80172

friction arm 400R/600R

mullionE85104

operating rod E 2308


striker 255 602
striker 255 603
gasket 130 180
frame E 85410

36

20

8
gasket 130 413

38.5

15
18

10
20

15
18

50

scale 3/4
E 85 technical catalogue
01.2011

5.5

E85CP5.5

41

77

transom E 85304

10

E 85

curtain wall system


projected thermo-break window with 2nd level transom

28
20

5 6

16

56

77

gasket 130 176/P6


sash E 85210
gasket 130 461

20

norton tape 6x6.4 mm

operating rod E 2308


self-drillingscrew
DIN7981 ST4.8x32-M-Z
gasket 130 180

structural seal 6 mm
33

gasket 130 131

striker 255 602


striker 255 603
frame E 85410
gasket 130 413

transom E 85304
45.8

14.4

gasket 130 706

38.5

gasket130457

50

36

31

gasket 130 470


thermalinsulationspacer80172

glazing shim 71 183


gasket130500
15
20

5 6

16

28

10

89

10

130

scale 3/4
E 85 technical catalogue
01.2011

41

E85CP5.6

5.6

E 85

curtain wall system


projected thermo-break window with 3rd level transom

28
20

5 6

16

56

77

gasket 130 176


sash E 85210
gasket 130 461

20

norton tape 6x6.4 mm

operating rod E 2308


self-drillingscrew
DIN7981 ST4.8x32-M-Z
gasket 130 180

gasket 130 131

33

structural seal 6 mm

striker 255 602


striker 255 603

38.5

gasket 130 706

frame E 85410
gasket 130 413

45.8

14.4

transom E 85304

50

36

31

glazing shim 71 185

gasket 130 474


thermalinsulationspacer80172

gasket130500
15

5 6

16

10

89

scale 3/4
E 85 technical catalogue
01.2011

41

E85CP5.7

5.7

E 85

curtain wall system


parallel opening thermo-break window

gasket 130 706

50

gasket130457

33

glass support E 85615

14.4

14.2
45.8

10.8

10

15

1
cover cap E 85713
pressureplateE85700

gasket 130 131

gasket130500
25

structural seal 6 mm

16

28

31

16
6

butyl seal 133 533

6
7

10

16

28
7

norton tape 6x6.4 mm

gasket 130 176 / P6


sash E 85211

56

23.5

gasket 130 461

gasket 130 470


thermalinsulationspacer80172

friction arm 900R/900L


operating rod E 2308

gasket 130 180


frame E 85410

36

20

38.5

15

gasket 130 413

18

10
20

15
18

77

transom E 85304

10

50

scale 3/4
E 85 technical catalogue
01.2011

5.8

E85CP5.8

41

mullionE85104

E 85

curtain wall system


parallel opening thermo-break window with 2nd level transom

28
20

5 6

16

56

77

gasket 130 176/P6


sash E 85211
gasket 130 461

20

norton tape 6x6.4 mm

operating rod E 2308


self-drillingscrew
DIN7981 ST4.8x32-M-Z
gasket 130 180

structural seal 6 mm
33

gasket 130 131

friction arm 900R/900L


frame E 85410

gasket 130 413


transom E 85304

45.8

14.4

gasket 130 706

38.5

gasket130457

50

36

31

gasket 130 470


thermalinsulationspacer80172

glazing shim 71 183


gasket130500
15
20

5 6

16

28

10

89

10

130

scale 3/4
E 85 technical catalogue
01.2011

41

E85CP5.9

5.9

E 85

curtain wall system


parallel opening thermo-break window with 3rd level transom

28
20

5 6

16

56

77

gasket 130 176 / P6


20

sash E 85211
norton tape 6x6.4 mm

gasket 130 461


operating rod E 2308
selfdrillingscrew
DIN7981 ST4.8x32-M-Z
gasket 130 180

gasket 130 131

33

structural seal 6 mm

friction arm 900R/900L


frame E 85410

38.5

gasket 130 706

gasket 130 413

45.8

14.4

transom E 85304

50

36

31

glazing shim 71 180

gasket 130 474


thermalinsulationspacer80172

gasket130500
15

5 6

16

10

89

scale 3/4
E 85 technical catalogue
01.2011

41

E85CP5.10

5.10

E 85

curtain wall system


projected window

tappingscrew
DIN7981 ST5.5x45-C-H
thermalinsulationspacer80172

cover cap E 85713


50

25

thermal insulation spacer 80 177

10

15

pressureplateE85700
butyl seal 133 553

structural seal 6 mm

10

28

26

16

14

10

12

26

gasket130500

20

37.3

25

norton tape 6x6.4 mm

39.9

gasket 130 175

gasket 130 470

profile 8902
gasket 130 180

10.3

friction arm 400R/600R


spacer E 85640
sash E 85200

46.9

gasket 130 180


frame E 85400

14.3

51

65.3

3
15

gasket 130 458

18

gasket 130 409

3
10

10
20

15
18

transom E 85304

E85CP5.11

41

mullionE85104

scale 3/4
E 85 technical catalogue
01.2011

5.11

E 85

curtain wall system


projected window with 2nd level transom

6
25

14

gasket 130 175

26

39.9

10.3

87.9
gasket 130 180

14.3

sash E 85200

norton tape 6x6.4 mm

gasket 130 180

51

37.3

gasket 130 458

65.3

structural seal 6 mm

frame E 85400

10

gasket 130 409

50

spacer E 85640
thermal insulation spacer 80 177

gasket 130 470


thermalinsulationspacer80172
butyl seal 133 553
tappingscrew
DIN7981 ST5.5x45-C-H
gasket130500
transomE85304
mullionE85104
15
20

5 6

16

28

10

89

10

130

scale 3/4
E 85 technical catalogue
01.2011

41

E85CP5.12

5.12

E 85

curtain wall system


projected window with 3rd level transom

6
25

14

gasket 130 175

26

39.9

10.3

87.9
gasket 130 180

14.3

sash E 85200

norton tape 6x6.4 mm

gasket 130 180

51

37.3

gasket 130 458

65.3

structural seal 6 mm

frame E 85400

10

gasket 130 409

gasket130500

50

butyl seal 133 553

thermal insulation spacer 80 177

gasket 130 474


thermalinsulationspacer80172
tappingscrew
DIN7981 ST5.5x45-C-H
transomE85354
mullionE85104
15
20

5 6

16

28

6 4 6

89

10

130

scale 3/4
E 85 technical catalogue
01.2011

41

E85CP5.13

5.13

E 85

curtain wall system


window in curtain wall

thermalinsulationspacer80172
102
41.5
5
gasket 130 470
additional profile E 85641

50
55.5

14

11

10

15

1
cover cap E 85713
pressureplateE85700

gasket 130 152


gasket130500

gasket 130 411

16

9.5

12

28

16.5

15

gasket 130 161

39

gasket 130 470

gasket130177

gasket 130 413


21

glazing bead 5380

53.5

26.5

103

100.5

sash E 2482
gasket 130 131
frame E 2424

transom E 85304

E85CP5.14

mullionE85104

scale 3/4
E 85 technical catalogue
01.2011

5.14

E 85

curtain wall system


window in curtain wall with 2nd level transom

28
20

16

39
gasket130177

gasket 130 411

42.5

21

glazing bead 5380

gasket 130 161

103

103

53.5

gasket 130 152

55.5

sash E 2482
gasket 130 131

gasket 130 470

frame E 2424
gasket 130 413

26.5

additional profile E 85641

50

59.5

tappingscrew
DIN7981 ST5.5x45-C-H

16.5

9.5

12

glazing shim 71 184


PVCspacer9020

thermalinsulationspacer80172
15

28

10

transomE85304
gasket 130 470

E85CP5.15

mullionE85104

scale 3/4
E 85 technical catalogue
01.2011

5.15

E 85

curtain wall system


window in curtain wall with 3rd level transom

28
20

16

39
gasket130177

gasket 130 411

41.5

21

glazing bead 5380

gasket 130 161

103

102

53.5

gasket 130 152

55.5

sash E 2482
gasket 130 131

gasket 130 470

frame E 2424
gasket 130 413

26.5

additional profile E 85640

50

59.5

tappingscrew
DIN7981 ST5.5x45-C-H

16.5

9.5

glazing shim 71 185

PVCspacer9020

thermalinsulationspacer80172

transomE85354
5

28

4 6

gasket 130 474

mullionE85104

scale 3/4
E 85 technical catalogue
01.2011

5.16

E85CP5.16

15

E 85

curtain wall system


door in curtain wall

cover cap E 85713


pressureplateE85700
tappingscrew
DIN7981 ST5.5x45-C-H
thermalinsulationspacer80172
134.9
92
gasket 130 470

35.9

50
18.3

6.7

10

15

gasket 130 152


17.1

gasket 130 411


gasket 130 177

16

28

butil seal 133 550

31.6

10

28

gasket130500

gasket 130 470

21
glazing bead E 5307

46

60.9
2

134.9

gasket 130 413

sash E 2443
gasket 130 152

108.4

frame E 2445

transom E 85304

E85CP5.17

mullionE85104

scale 3/4
E 85 technical catalogue
01.2011

5.17

E 85

curtain wall system


door in curtain wall with 2nd level transom

tappingscrew
DIN7981 ST5.5x45-C-H
thermalinsulationspacer80172
glazing shim 71 183
5

28

10

28

10

transomE85304

6.7

18.3

50

10

15

15

gasket 130 413


67.4
gasket 130 470

35.9

12.1

60.9

mullionE85104
frame E 2445

134.9

5
134.9

41

46

92

gasket 130 152

sash E 2443

16

31.6

gasket 130 177

28

gasket130411

scale 3/4
E 85 technical catalogue
01.2011

5.18

E85CP5.18

21

glazing bead E 5307

E 85

curtain wall system


door in curtain wall with 3rd level transom

tappingscrew
DIN7981 ST5.5x45-C-H
gasket 130 474
thermalinsulationspacer80172
glazing shim 71 185
5

28

10

28

10

transomE85354

6.7

18.3

50

10

15

15

35.9

12.1

gasket 130 413


67.4

41

60.9

gasket 130 474

frame E 2445

134.9

134.9

mullionE85104

46

92

gasket 130 152

sash E 2443

16

31.6

gasket 130 177

28

gasket130411

scale 3/4
E 85 technical catalogue
01.2011

5.19

E85CP5.19

21

glazing bead E 5307

E 85

curtain wall system


split mullion

50
15

10

10

15

tappingscrew
DIN7981 ST5.5x45-C-H
cover cap E 85713

20

15

butyl seal 133 553


gasket130500

16
10

min 6

28
10

6 5

25

pressureplateE85700

gasket 130 470


15 10

1
173

16

10
20

15

thermalinsulationspacer80172
gasket76651

16

flange 76 674

89

tappingscrew
DIN7981 ST4.8x19-C-H
gasket 130 198

110

11.5

32

6.5

gasket 130 199


supplementary profile E 85150
mullionE85153
fixing part 71 113

21

transom E 85304

22.5

self-drillingscrew
DIN7981 ST3.5x18-M-Z
supplementaryprofileE85151

22.5

gasket 130 199

E85CP5.20

50

scale 3/4
E 85 technical catalogue
01.2011

5.20

E 85

curtain wall system


mullion for substructure

50
15

10

10

15

tappingscrew
DIN7981 ST5.5x45-C-H

cover cap E 85713

pressureplateE85700

gasket130500

28

10

16

15

25

butyl seal 133 553

128

gasket 130 470


29

103

thermalinsulationspacer80172
gasket 76 651
transom E 85301
flange 76 671

36

tappingscrew
DIN7981 ST4.8x19-C-H
mullion E 85120

7.5

cap E 19641
nut
DIN 934-A2-70
washer
DIN125 8-A2-70

spring washer
DIN127 8-A2-70
PVC

E85CP5.21

bush 10x2

scale 3/4
E 85 technical catalogue
01.2011

cheeseheadscrew
DIN931 M8x30-A2-70

5.21

E 85

curtain wall system


outer corner 90
90

etalbond

hard insulation 20 mm
seal 4 mm
selfdrillingscrew
DIN7981 ST3.5x18-M-Z
aluminium sheet 2 mm
1
4.33

cover cap E 85713


tappingscrew
DIN7981 ST5.5x45-C-H
pressureplateE85700
gasket130500
butyl seal 133 553
25

etalbond

75

hard insulation 20 mm
soft insulation 31.5 mm

1
4.33

31.5

20

16

25

mullionE85130

15

10

50

15

10

blind rivet
DIN 7337 A4.8x8-A
thermal insulation spacer 80 177

flange 76 674
gasket 076 651
gasket130457
transom E 85304
90

28

scale 3/4
E 85 technical catalogue
01.2011

5.22

20
25

E85CP5.22

E 85

curtain wall system


outer corner 90
90

94

10

100

seal 10 mm
silicone coating
soft insulation 40 mm

min 6

etalbond

110

100

min 6

mullionE85130
tappingscrew
DIN7981 ST4.8x19-C-H

gasket 076 651


gasket130457
1

transom E 85304
90

scale 3/4
E 85 technical catalogue
01.2011

16

6 5

15

28

15

E85CP5.23

note:
it is necessary to calculate
measures for each project

5.23

E 85

curtain wall system


outer corner 90
90

etalbond
hard insulation
thermalinsulationspacer80174

50
10

15

10

20.4

25

10

35.4

25

35.4

spacerE85655

20.4

15

suppl.mullionprofileE85143
gasket130457

15

10

50

15

tappingscrew
DIN7981 ST5.5x45-C-H

transom E 85354

scale 3/4
E 85 technical catalogue
01.2011

5.24

16

E85CP5.24

89

28

E 85

curtain wall system


outer corner 90

90
etalbond

hard insulation 20 mm
seal 4 mm
self-drillingscrew
DIN7981 ST3.5x18-M-Z
aluminium sheet 2 mm

50
10

15

10

thermal insulation spacer 80 177


hard insulation 20
etalbond

28

16

6 5

15

165
tappingscrew
DIN7981 ST5.5x38-C-H
thermalinsulationspacer80174

15

1
4.36

10

152

20

28
gasket130457

240

self-drillingscrew
DIN7981 ST4.8x19-M-Z

165

89

hard insulation 40 mm
1
4.36

L-profilesection 4065

50

E85CP5.25

15

10

50

15

10

41

blind rivet
DIN 7337 A4.8x8-A

not to scale
E 85 technical catalogue
01.2011

5.25

E 85

curtain wall system


outer corner 90

90

max 500
22

10

6 5

15

16

23

28

min 6

20

seal 10 mm

6
7

thermal Insulation spacer 80 174

6 5

15

tappingscrew
DIN7981 ST5.5x45-C-H

10

28

seal 10 mm
gasket130457

flange 76 674

max 500

130

89

weldedseam 3 mm

41

transom E 85304
mullionE85104

E85CP5.26

note:
the glass thickness should be
checked by the facade engineer

not to scale
E 85 technical catalogue
01.2011

5.26

E 85

curtain wall system


inner corner 90

90

gasket130500
pressureplateE85700

50

cover cap E 85713

tappingscrew
DIN7981 ST5.5x38-C-H
thermalinsulationspacer80174

min 5

min 5

thermal insulation spacer 80 177

58

hard insulation 20 mm

16

28

blind rivet
DIN 7337 A4.8x8-A

73

30

65

15

30

gasket130457

6 5

25

gasket130457

151

73
58

190

65

154

etalbond

130

89

welded seam 3 mm

130

mullionE85104

130

flange 76 674

transom E 85304

151
154

E85CP5.27

41

50

not to scale
E 85 technical catalogue
01.2011

5.27

E 85

curtain wall system


inner corner 90

90
gasket130500
cover cap E 85731

16
7

28

pressure plate E 85740

15

130
145
suppl.mullionprofileE85142
thermalinsulationspacer80172
tappingscrew
DIN7981 ST5.5x45-C-H

E85CP5.28

41

130

89

tappingscrew
DIN7981 ST5.5x16-C-H

scale 3/4
E 85 technical catalogue
01.2011

5.28

E 85

curtain wall system


outer corner 45 - 150
45-150

32
etalbond

soft insulation 24 mm
seal 4 mm
selfdrillingscrew
DIN7981 ST3.5x18-M-Z
1
4.41

aluminium sheet 2 mm

thermal insulation spacer 80 177


tappingscrew
DIN7981 ST5.5x45-C-H

50

etalbond
soft insulation 24 mm

1
4.41

gasket130457
24
32

16

28

thermalinsulationspacer80174

32

50

selfdrillingscrew
DIN7981 ST4.8x19-M-Z
L-profilesection 4010 Aluminum
aluminium sheet 2 mm
supplementaryprofileE85150
gasket 130 199
membrane 1 mm
mullionE85153
gasket 130 198
gasket 130 199

transom E 85304

-150

E85CP5.29

4 5

scale 3/4
E 85 technical catalogue
01.2011

5.29

E 85

curtain wall system


inner corner 135

135

tappingscrew
DIN7981 ST5.5x38-C-H
cover cap E 85732
pressure plate E 85741

26.6
28
7

16

6 5

21.6

gasket130500

gasket130457
flange 76 674

thermalinsulationspacer80174

90

89

tappingscrew
DIN7981 ST4.8x19-C-H
mullion E 85135

135

E85CP5.30

transom E 85304

scale 3/4
E 85 technical catalogue
01.2011

5.30

E 85

curtain wall system


outer corner 30-90
30-90

L-profilesection 4134
etalbond
soft insulation
30-90

cover cap E 85713


tappingscrew
DIN7981 ST5.5x38-C-H
pressureplateE85700
butyl seal 133 553
gasket130500
butyl seal

9.5

15

28

16

selfdrillingscrew
DIN7981 ST4.8x19-M-Z

transomE85300
split rotating mullion E 85141
suppl. mullion E 85140
90

tappingscrew
DIN7981 ST5.5x32-C-H

E85CP5.31

mullionE85102

scale 3/4
E 85 technical catalogue
01.2011

5.31

E 85

curtain wall system


polygonal facade with outer angle max 5
50

15

10

10

15

tappingscrew
DIN7981 ST5.5x45-C-H
cover cap E 85713
pressureplateE85700

butyl seal 133 553


15

20

gasket130500
5 6
16

28

6 4

gasket 130 470


35

39

thermalinsulationspacer80172
flange 76 661

15

10

10

15

transom E 85351

mullion E 85101

polygonal facade with inner angle max 5


50

10

10

15

15

tappingscrew
DIN7981 ST5.5x45-C-H
cover cap E 85713
pressureplateE85700
gasket130500

16
4 6

28

6 5

20

15

butyl seal 133 553

35

39

gasket 130 470


thermalinsulationspacer80172
flange 76 661

transom E 85351
3

15

10

10

15

E85CP5.32

mullion E 85101

scale 3/4
E 85 technical catalogue
01.2011

5.32

E 85

curtain wall system


outer angles 0~15

tappingscrew
DIN7981 ST5.5x55-C-H
cover cap E 85711
pressure plate E 85703
butyl seal 133 553

0-15

gasket130500

12
17
5 6
16

28

6 4

10

gasket 130 474

spacer E 85650
thermal insulation spacer 80 172

tappingscrew
DIN7981 ST5.5x55-C-H

outer angles 7.5~22.5

cover cap E 85711


pressure plate E 85704
butyl seal 133 553

7.5-22.5

gasket130500

12
17
5 6
16

28

6 4
4

10

5
gasket 130 474

thermal insulation spacer 80 172

scale 3/4
E 85 technical catalogue
01.2011

5.33

E85CP5.33

spacer E 85651

E 85

curtain wall system


outer angles 15~30

tappingscrew
DIN7981 ST5.5x60-C-H
cover cap E 85711
pressure plate E 85705
15-30

butyl seal 133 553


gasket130500
thermal insulation spacer 80 172
gasket 130 474
spacer E 85652

12
5

17

6
16
28
6 4
4

10

tappingscrew
DIN7981 ST5.5x60-C-H
cover cap E 85711

outer angles 22.5~37.5

pressure plate E 85706


22.5

butyl seal 133 553

-37.5

gasket130500
thermal insulation spacer 80 172
gasket 130 474

12

spacer E 85653

17

6
16
28
6
4

10

E85CP5.34

scale 3/4
E 85 technical catalogue
01.2011

5.34

E 85

curtain wall system


outer angles 30~45

tappingscrew
DIN7981 ST5.5x60-C-H
cover cap E 85711
pressure plate E 85707
butyl seal 133 553
45
30-

gasket130500
thermal insulation spacer 80 172
gasket 130 474
spacer E 85654

12
5

17

6
16
28
6
4
4

10

outer angles 37.5~52.5

tappingscrew
DIN7981 ST5.5x60-C-H
cover cap E 85711
pressure plate E 85708

3 7. 5

butyl seal 133 553

.5
-52

thermal insulation spacer 80 172


gasket130500
gasket 130 474
spacer E 85655`
12
5

17
6
16
6

28

10

E85CP5.35

scale 3/4
E 85 technical catalogue
01.2011

5.35

E 85

curtain wall system


roof connector

tappingscrew
DIN7981 ST5.5x68-C-H
cover cap E 85711
pressure plate E 85706
butyl seal
gasket130500
thermal insulation spacer 80 172
2

gasket 130 470


12
5

19

spacer E 85653
6
5
0.3
14
4

35
28.

44
4

transomE85305
mullion connector E 85960 below

E85CP5.36

mullionE85104

scale 3/4
E 85 technical catalogue
01.2011

5.36

scale 1:2

15

10

50

10

15

flange 76 674

gasket 76 651

thermalinsulationspacer80172

gasket 130 470

butyl seal 133 553


gasket130500

pressureplateE85700

cover cap E 85713

tappingscrew
DIN7981 ST5.5x45-C-H

28
10
43
12.5

255

15
6 5
16
6
10

E 85 technical catalogue
01.2011

E85CP5.37

soft insulation 50 mm

gypsum board

mullionE85104

transom E 85305

1
15

10

50
10

15

curtain wall system

E 85

connection between curtain wall and partition wall

5.37

E85CP5.38

mullionE85104

flange 76 674

gasket 76 651

15

10

50

10

15

bracket 71090

thermalinsulationspacer80172

gasket 130 470

gasket130500

butyl seal 133 553

pressureplateE85700

cover cap E 85713

tappingscrew
DIN7981 ST5.5x45-C-H

insulation soft

sheet aluminium 2 mm
membrane 2 mm

thermal insulation spacer 80 177

255

2
2
24
10
130

E 85 technical catalogue
01.2011

5.38

40

scale 1:2

transom E 85305

1
15

10

50
10

15

curtain wall system

E 85

delatation

208

E 85

curtain wall system


connection with backing wall

concrete wall
membrane 2 mm
hard insulation 50 mm
plaster
seal 2 mm
etalbond

20
10

10

17

28

16

1
4

6 5

15

butyl seal 133 553

gasket 130 470

89

thermalinsulationspacer80172

E85CP5.39

41

130

additional profile E 85620

scale 3/4
E 85 technical catalogue
01.2011

5.39

E 85

curtain wall system


connection with rainscreen cladding system BRAVO

50
butyl seal 133 553
thermal insulation spacer 80 177

28

29

etalbond

gasket 130 470

membrane 1 mm

177

206

bravo system by ETEM

E85CP5.40

gypsum board

scale 3/4
E 85 technical catalogue
01.2011

5.40

E 85

curtain wall system


connection with rainscreen cladding system Forte

28
10

34

30

50

25

stone

43

forte system by ETEM

49

metal aluminum sheet


hard insulation
membrane

51

soft insulation

41

additional profile E 85611

E85CP5.41

suppl. profile E 85610

scale 3/4
E 85 technical catalogue
01.2011

5.41

E 85

curtain wall system


conservatories vertical section with 2nd level transom

135

covercapE85730
thermalinsulationspacer80174
20

tappingscrew
DIN7981 ST5.5x38-C-H

5
6

pressureplateE85701

14

butyl seal 133 553

8.4

etalbond

hard insulation 17 mm
membrane 1 mm
29

gasket130457
glazing shim 71 184
110

135

32

transomE85320
gasket 130 199

32

tappingscrew
DIN7981 ST5.5x38-C-H

thermalinsulationspacer80174

accessory 74 674
gasket130457

E85CP5.42

machine cutting
for transom slot

scale 3/4
E 85 technical catalogue
01.2011

5.42

E 85

curtain wall system


conservatories vertical section with 3rd level transom

90-150

20
5
28

covercapE85730

.4

14

thermalinsulationspacer80174

8.4

tappingscrew
DIN7981 ST5.5x38-C-H

pressureplateE85701
butyl seal 133 553
55

etalbond
hard insulation 30 mm

gasket 130 473

membrane 1 mm

transomE85370
suppl.profileE85670

30-

90

glazing shim 71 185

tappingscrew
DIN7981 ST5.5x38-C-H
thermalinsulationspacer80174
gasket 130 473

20

28

E85CP5.43

accessory 74 674

scale 3/4
E 85 technical catalogue
01.2011

5.43

E 85

curtain wall system


conservatories vertical section

90-150

20

pressureplateE85701
covercapE85730

5
6

self-drillingscrew
DIN7981 ST4.8x19-M-Z

28 . 4

14

8.4

2
113.

20

thermalinsulationspacer80174
gasket130457

5 4

glazing shim 71 180


tappingscrew
DIN7981 ST5.5x38-C-H
89

44

mullion is trimmed
etalbond

100

41

113.2

hard insulation 26 mm
membrane 1 mm

.7

etalbond

cut for membrane in mullion

thermal insulation spacer 80 184

tappingscrew
DIN7981 ST4.2x25-C-H

67.4

Fprofile31064

tappingscrew
DIN7981 ST5.5x38-C-H
thermalinsulationspacer80174
gasket130457

25

5 6

16
28

89

130

not to scale
E 85 technical catalogue
01.2011

41

E85CP5.44

20

5.44

E 85

curtain wall system


conservatories vertical section

115

20

pressureplateE85701
covercapE85730

5
6
14

13 1

117.2

8.4
7

thermalinsulationspacer80174
tappingscrew
DIN7981 ST5.5x38-C-H
gasket130457

13.9

glazing shim 71 184


mullion connector E 85969 below

10

14.4

10

89

seal 10 mm

seal 10 mm

82.4

96.8

41

5 6

16

89

41

tappingscrew
DIN7981 ST5.5x38-C-H

glazing shim 71 184

15

10

50

10

15

115

20

thermalinsulationspacer80174
gasket130457
20
25

5 6

16
28

89

E85CP5.45

note:
the glass thickness should be
checked by the facade engineer

scale 3/4
E 85 technical catalogue
01.2011

41
130

5.45

E 85

curtain wall system


conservatories vertical section

20
5
6

tappingscrew
DIN7981 ST4.2x32-C-H

14
8.4
6.7

soft insulation 40 mm
.8
166

47.7

10

89

seal 10 mm
silicone coating

115

96.4

etalbond

5 6

16

89

scale 3/4
E 85 technical catalogue
01.2011

41

E85CP5.46

20
note:
the glass thickness
should be checked by the
facade engineer

5.46

E 85

curtain wall system


slope > 25

tappingscrew
DIN7981 ST5.5x45-C-H
butyl seal 133 553
covercapE85730
pressureplateE85701
gasket130500
8
>25

12

20
5
6

4 4
14
0.35
5
28.3
10

gasket 130 470


thermalinsulationspacer80172
89

glazing shim 71 183


transomE85304

E85CP5.47

mullionE85104

scale 3/4
E 85 technical catalogue
01.2011

5.47

E 85

curtain wall system


slope > 15

pressure plate E 85702


tappingscrew
DIN7981 ST5.5x45-C-H
gasket 130 126
silicone gasket 130 705

18
20
2
6
5 6

>15

4 4
14
0.35
28.35
10

gasket 130 470


thermalinsulationspacer80171
glazing shim 71 184

E85CP5.48

mullionE85104

89

transomE85304

scale 3/4
E 85 technical catalogue
01.2011

5.48

E 85

curtain wall system


slope > 7

flat bar 9070 / 50x2 mm


tappingscrew
DIN7981 ST5.5x45-C-H
silicone gasket 130 705
butyl seal 133 553

22

20

2
5 6
1.2
10

>7

14 4 4
0.35

28.35

gasket 130 470


thermalinsulationspacer80171
glazing shim 71 184
89

transomE85304

E85CP5.49

mullionE85104

scale 3/4
E 85 technical catalogue
01.2011

5.49

E 85

curtain wall system


connection with backing wall

aluminium sheet 1.5 mm

1.5

61.5

seal 5 mm
hard insulation 50 mm

10

46.5

membrane 1 mm

4.5

aluminium sheet 1.5 mm

10

hard insulation 25 mm
membrane 1 mm
hard insulation 31.5 mm

self-drillingscrew
DIN7981 ST4.2x16-O-Z
1.5
25
1
31.5
1
1.5
89

bracket E 85913

41

40

not to scale
E 85 technical catalogue
01.2011

5.50

E85CP5.50

reinforced concrete

E 85

curtain wall system


bottom finishing

water drainage

gasket130500
thermal insulation spacer 80 177
additional profile E 85612

24

38

cut for membrane in mullion


etalbond

27

hard insulation 60 mm

bracket 71 050
membrane

30

hard insulation

plaster

E85CP5.51

hard insulation 50 mm

scale 3/4
E 85 technical catalogue
01.2011

5.51

E 85

curtain wall system


bottom finishing

water drainage

20

28

10

109

21

vapor barrier
membrane

aluninium sheet
thermal insulation spacer 80 177
tile
hard insulation
additional profile E 85612
cut for membrane in mullion
membrane

E85CP5.52

ground tiles

scale 1:2
E 85 technical catalogue
01.2011

5.52

E 85

curtain wall system


finishing to suspended ceiling

water drainage
20

mullionE85104

5 6

28
16

6 10

transom E 85306
gasket 130 470
glazing shim 71 183
butyl seal 133 553

sheet steel 1.5 mm

tappingscrew
DIN7981 ST5.5x45-C-H
thermalinsulationspacer80172
thermal insulation spacer 80 177
additional profile E 85612
cut for membrane in mullion

etalbond

washer DIN 440

bracket 71 270

membrane
concrete slab

hard insulation 60 mm

perforation

tube
aluminum 60x30x2
self-drillingscrew
DIN7981 ST5.5x19-M-Z

E85CP5.53

vivo system by ETEM

not to scale
E 85 technical catalogue
01.2011

5.53

E 85

curtain wall system


finishing of plaster ceiling

L-profilesection 4065

60

90

30

self-drillingscrew
DIN7981 ST4.8x19-M-Z

etalbond

membrane

membrane

additional profile E 85612


thermal insulation spacer 80 177

hard insulation 32 mm

24

10

33

76

50

bracket 71 050

transom E 85305
20
25

5 6

16
28

10
10

mullionE85104
gasket 130 470

E85CP5.54

thermalinsulationspacer80172

scale 3/4
E 85 technical catalogue
01.2011

5.54

E 85

curtain wall system


outer angle vertical section

25
20

gasket130457

28
5 6

16

130

89

41

thermalinsulationspacer80174

15

10

50

10

15

tappingscrew
DIN7981 ST5.5x45-C-H

thermal insulation spacer 80 177


28
hard insulation 20 mm

20

5 4

20

96

etalbond
mullion E 85104
mullion connector E 85960 below

15
10
10

50

E85CP5.55

15

not to scale
E 85 technical catalogue
01.2011

5.55

E 85

curtain wall system

89

16

28

89

41

130

41

inner angle vertical section

25

16

15
6

10
15
20

50

10

86.
86.

86.6

mullion connector E 85960 below

20

5 6

16

20

5 6

16

89

15

tappingscrew
DIN7981 ST5.5x45-C-H

10

50

10

15

86.6

mullion E 85104

thermalinsulationspacer80174

25

28

not to scale
E 85 technical catalogue
01.2011

5.56

89

41
130

E85CP5.56

gasket130457

E 85 technical catalogue
01.2011
3M tape

5.57

E85CP5.57

0.38
25

thermalinsulationspacer80172

gasket130500

tappingscrew
DIN7981 ST5.5x45-C-H

butyl seal 133 553

glazing shim 71 183

transom E 85305

mullionE85104

perforation

bracket 71 072

soft insulation

laminated glass 4.4.1

sheet steel 2 mm

transom E 85380

thermal insulation spacer 80 177

scale 1:2
4

min 30

fire resistant silicone (1250C)

steel sheet 2 mm

washer DIN 440

profile E 8863

profile E 8656

curtain wall system

E85

glass spandrel panel in brustung zone

scale 1:2
butyl seal 133 553

gasket130500

tappingscrew
DIN7981 ST5.5x45-C-H

50

E85CP5.58

thermalinsulationspacer80172

gasket130500

tappingscrew
DIN7981 ST5.5x45-C-H

butyl seal 133 553

membrane

transom E 85305

mullionE85104

vario system by ETEM

adaptor

ceramic tile
Agrob Buchtal

soft insulation

membrane

aluminum sheet 1 mm

15
15

5.58

50

E 85 technical catalogue
01.2011
thermalinsulationspacer80172

20

28

10

109

21

curtain wall system

E85

ceramic tiles in brustung zone rainscreen cladding system VARIO

E 85 technical catalogue
01.2011
5.59
gasket 130 470

thermalinsulationspacer80172

tappingscrew
DIN7981 ST5.5x45-C-H

butyl seal 133 553

gasket130500

thermalinsulationspacer80177

transom E 85305

mullionE85104

bracket 71 072

soft insulation

etalbond

thermalinsulationspacer80177

thermalinsulationspacer80172

E85CP5.59

scale 1:2
tappingscrew
DIN7981 ST5.5x45-C-H

butyl seal 133 553

glazing shim 71 183


gasket130500

gasket 130 470

transom E 85305

20
2

membrane

gasket 130 480

151

123

gasket 130 480

membrane

fire resistant silicone (1250C)

steel sheet 2 mm

washer DIN 440

steel sheet 2 mm

aluminium sheet 2 mm

130

curtain wall system

E85

etalbond spandrel panel in brustung zone

min 5

scale 1:2
E85CP5.60

membrane

forte system by ETEM

bracket E 85967

metal aluminum sheet

additional profile E 85611

cover cap E 85720

pressureplateE85700

thermalinsulationspacer80174

cover cap E 85720

pressureplateE85700

thermalinsulationspacer80174

thermal insulation spacer 80 184

membrane

hard insulation

forte system by ETEM

8
50
50

E 85 technical catalogue
01.2011
50

soft insulation

25

25

28

28

10

10

15

gasket 130 470

glazing shim 71 184

transomE85300

glazing shim 71 184

gasket 130 470

89

bracket 71 050
membrane

transomE85304

gasket 130 470

bracket 71 050

transomE85304

curtain wall system

E85

connection with rainscreen system Forte

5.60

47

E 85

curtain wall system


usage of hidden transom on floor level

gasket 130 474


transom E 85380
self-drillingscrew
DIN7981 ST4.8x19-M-Z
steel sheet 2 mm
waterproof
gypsum board

washer DIN 440

bracket 71 072
steel sheet 2 mm
fire resistant silicone (1250C)

soft insulation

25
20

28
5 6

16

6 10

min 30

12.5

50

21

mullionE85104
transom E 85305
gasket 130 470
glazing shim 71 183
butyl seal 133 553

tappingscrew
DIN7981 ST5.5x45-C-H
gasket130500

E85CP5.61

thermalinsulationspacer80172

not to scale
E 85 technical catalogue
01.2011

5.61

E 85

curtain wall system


upper finishing with etalbond

min 6

10

1
4.23

1
4.23

etalbond
membrane

thermal insulation spacer 80 177

thermalinsulationspacer80172

soft insulation

gypsum board

min 30

bracket 71 270

thermalinsulationspacer80172
tappingscrew
DIN7981 ST5.5x45-C-H

mullionE85104
transom E 85305

E85CP5.62

gasket 130 470


glazing shim 71 183

not to scale
E 85 technical catalogue
01.2011

5.62

STRUCTURAL
GLAZING
SECTIONS

DETAILS

E 85

curtain wall system


mullion with 2nd level transom

silicone seal
silicone gasket 130 705
tappingscrew
DIN7982 ST5.5x25-C-H
15

20
10

15

glazing clip 71 116

10

20
6

32
6

spacer E 85990

gasket 130 463

15

gasket 76 651
flange 76 674
5

tappingscrew
DIN7981 ST4.8x19-C-H

89

3
130

15
18

10

10
20

15
18

fixing part 71 113

transom E 85304
6
41

mullionE85104

E85SG6.1

50

scale 3/4
E 85 technical catalogue
01.2011

6.1

E 85

curtain wall system


transom 2nd level drainage

spacer E 85990
glazing clip 71 116
gasket 130 463
flange 76 674
glazing shim 71 184

56.3

50
tappingscrew
DIN7982 ST5.5x25-C-H

15

10

20

10

15

mullion E 85104

fixingpart71113
transomE85304
gasket 076 651 behind
thermal insulation spaser
80 171/80 183
silicone gasket 130 705
silicone seal
20
32

89

130

note:
spacer E 85990 has to be used only with 2nd level transoms
scale 3/4
E 85 technical catalogue
01.2011

41

6.2

E85SG6.2

E 85

curtain wall system


mullion with 2nd level transom

15

20

15
10

spacer 33 879

min 6

10

silicone seal
silicone gasket 130 705
thermal insulation spaser
80 171/80 183
tappingscrew
DIN7982 ST5.5x25-C-H
glazing clip 71 130

16
12

min 6

28
12

3M tape

15

gasket 130 480


gasket 76 651
flange 76 674
5

tappingscrew
DIN7981 ST4.8x19-C-H

89

130

15
18

10

10
20

15
18

fixing part 71 113

transom E 85304
6
41

mullionE85104

E85SG6.3

50

scale 3/4
E 85 technical catalogue
01.2011

6.3

E 85

curtain wall system


transom 2nd level drainage

spacer 33 879
glazing clip 71 130
gasket 130 480

15

flange 76 674
glazing shim 71 184

56.3

50
tappingscrew
DIN7981 ST5.5x25-C-H

min 6

15

10

20

10

thermal insulation spaser


80 171/80 183

fixingpart71113
transomE85304
gasket 076 651 behind
silicone gasket 130 705
silicone seal
mullion E 85104
16
28

12

89

12

130

scale 3/4
E 85 technical catalogue
01.2011

41

E85SG6.4

6.4

E 85

curtain wall system


transom 3rd level drainage

spacer 33 879
glazing clip 71 130
gasket 130 463
glazing shim 71 185

15

flange 76 664

56.3

50
tappingscrew
DIN7981 ST5.5x25-C-H

min 6

15

10

20

10

thermal insulation spaser


80 171/80 183

fixingpart71113
transomE85354
6

silicone flange 76 680 behind


silicone gasket 130 705
silicone seal
mullion E 85104

16
28

12

89

12

130

scale 3/4
E 85 technical catalogue
01.2011

41

E85SG6.5

6.5

E 85

curtain wall system


projected thermo-break window

thermal insulation spacer


80 171/80 183

silicone seal
silicone gasket 130 705

glass support E 85614


gasket 130 707
gasket 130 479

55.5

structural seal 6 mm

2
7.9

tappingscrew
DIN7981 ST5.5x25-C-H
glazing clip 71 130

33.3
1.6
20.8

spacer 33 879 + 3M tape

16
6

9.2

16

28
7

norton tape 6x6.4 mm

gasket 130 176

56

sash E 85210
spacer 700R
gasket 130 461

gasket 130 480

friction arm 400R/600R


operating rod E 2308
6

striker 255 602


striker 255 603
gasket 130 180
frame E 85410

38.2

20

38.5

14
16

10
21

15

18

77

transom E 85304

11

50

scale 3/4
E 85 technical catalogue
01.2011

6.6

E85SG6.6

41

mullionE85104

E 85

curtain wall system


projected thermo-break window with 2nd level transom

6
6

16
6

56

38.2
gasket 130 176

16

sash E 85210
gasket 130 461

20

norton tape 6x6.4 mm

operating rod E 2308


self-drillingscrew
DIN7981 ST4.8x32-M-Z
gasket 130 180

structural seal 6 mm

striker 255 602


striker 255 603

38.5

glass support E 85614

55.5

gasket 130 479

gasket 130 707

frame E 85410

16

1.6

9.2

50

20.8

glazing shim 71 182

min 6

15

33.3

2
7.9

14

transom E 85304

fixingpart71113
transomE85304
gasket 076 651 behind
gasket 130 480
silicone gasket 130 705
silicone seal
mullion E 85104
41
130

scale 3/4
E 85 technical catalogue
01.2011

6.7

E85SG6.7

89

E 85

curtain wall system


projected thermo-break window with 3rd level transom

6
6

16
6

56

38.2
gasket 130 176

16

sash E 85210
gasket 130 461

20

norton tape 6x6.4 mm

operating rod E 2308


self-drillingscrew
DIN7981 ST4.8x32-M-Z
gasket 130 180

structural seal 6 mm
gasket 130 473

striker 255 602


striker 255 603
38.5

55.5

glass support E 85614


gasket 130 707

frame E 85410

16

50

1.6

20.8

glazing shim 71 180

min 6

15

33.3

2
7.9

14

transomE85354

flange 76 664
fixing part 71 113
gasket 076 651 behind
gasket 130 463

1.1

silicone gasket 130 705


silicone seal
mullion E 85104
16
28

89

12

130

scale 3/4
E 85 technical catalogue
01.2011

41

6.8

E85SG6.8

E 85

curtain wall system


parallel opening thermo-break window

silicone seal
silicone gasket 130 705
glass support E 85614
gasket 130 707
gasket 130 479

55.5

structural seal 6 mm

2
7.9

80 171 / 80183
tappingscrew
DIN7981 ST5.5x25-C-H
glazing clip 71 130

33.3
1.6
20.8

spacer 33 879 + 3M tape

16
6

9.2

16

28
7

norton tape 6x6.4 mm

gasket 130 176 / P6


sash E 85211

gasket 130 480

56

gasket 130 461


friction arm 900R/900L
operating rod E 2308
6

gasket 130 180


2
20

38.5

14

gasket 130 413


transom E 85304

16

11

10
21

15

18

79.2

38.2

frame E 85410

50

scale 3/4
E 85 technical catalogue
01.2011

6.9

E85SG6.9

41

mullionE85104

E 85

curtain wall system


parallel opening thermo-break window with 2nd level transom

6
6

16
6

56

38.2
gasket 130 176 / P6

16

sash E 85211
gasket 130 461

20

norton tape 6x6.4 mm

operating rod E 2308


self-drillingscrew
DIN7981 ST4.8x32-M-Z
gasket 130 180

structural seal 6 mm
gasket 130 479

friction arm 900R/900L


38.5

55.5

gasket 130 707

7.9

14

transom E 85304

9.2

50

20.8

glazing shim 71 182

33.3

frame E 85410

16

glass support E 85614

min 6

15

80 171 / 80183

fixingpart71113
flange 76 674
gasket 076 651 behind
gasket 130 480
silicone gasket 130 705
silicone seal
mullion E 85104
89

41

E85SG6.10

130

scale 3/4
E 85 technical catalogue
01.2011

6.10

E 85

curtain wall system


parallel opening thermo-break window with 3rd level transom

6
6

16
6

56

38.2
gasket 130 176 / P6

16

sash E 85211
gasket 130 461

20

norton tape 6x6.4 mm

operating rod E 2308


self-drillingscrew
DIN7981 ST4.8x32-M-Z
gasket 130 180

structural seal 6 mm
gasket 130 473

friction arm 900R/900L


38.5

55.5

glass support E 85614


gasket 130 707

frame E 85410

16

50

1.6

20.8

glazing shim 71 180


5

33.3

2
7.9

14

transomE85354

min 6

15

80 171 / 80183

flange 76 664
fixing part 71 113
gasket 076 651 behind
gasket 130 463
glazing clip 71 130

1.1

silicone gasket 130 705


silicone seal
mullion E 85104
16
28

89

12

130

scale 3/4
E 85 technical catalogue
01.2011

41

E85SG6.11

6.11

E 85

curtain wall system


window in curtain wall

116
41.5
5
gasket 130 480

36
69.5

additional profile E 85641

silicone gasket 130 705

gasket 130 152


min 6 mm *

21

gasket 130 161

11

10

thermal insulation spaser


80 171/80 183
glazing clip 71 130
spacer 33 879

28
12

11.7
12

12

16
6
9

28

16

gasket 130 411

15

30.5

15

gasket130177

gasket 130 413


89

130

glazing bead 5380


sash E 2482
gasket 130 131
frame E 2424
6

transom E 85304

50

* according to ETAG 002


scale 3/4
E 85 technical catalogue
01.2011

6.12

E85SG6.12

41

mullionE85104

E 85

curtain wall system


window in curtain wall

28
8

16

30.5
gasket130177

gasket 130 411

42.5

21

glazing bead 5380

sash E 2482

69.5

117

gasket 130 161

103

53.5

gasket 130 152

gasket 130 131


26.5

additional profile E 85641

frame E 2424

gasket 130 480

transomE85304

thermal insulation spaser


80 171/80 183

mullion E 85104

spacer 33 879
glazing clip 71 130

* according to ETAG 002

16
28

12

89

12

130

scale 3/4
E 85 technical catalogue
01.2011

41

6.13

E85SG6.13

silicone gasket 130 705

min 6

15

10

50

21

11

min 6 mm *
glazing shim 71 184

E 85

curtain wall system


window in curtain wall

28
8

16

30.5
gasket130177

gasket 130 411

42.5

21

glazing bead 5380

sash E 2482

69.5

117

gasket 130 161

103

53.5

gasket 130 152

gasket 130 131


26.5

additional profile E 85640

frame E 2424

gasket 130 480

10

50

21

11

glazing shim 71 185

15

11.7

transomE85354
gasket 130 463
mullion E 85104

16
28

89

12

130

scale 3/4
E 85 technical catalogue
01.2011

41

6.14

E85SG6.14

E 85

curtain wall system


outer corner 90
90

silicone seal
silicone gasket 130 705
tappingscrew
DIN7981 ST5.5x25-C-H
glazing clip 71 130

etalbond
hard insulatin
20

spacer 33 879 + 3M tape

41

41

gasket 130 480

suppl.mullionprofileE85143

20

spacerE85655

tappingscrew
DIN7981 ST5.5x45-C-H

transom E 85354
89

12

scale 3/4
E 85 technical catalogue
01.2011

16

28

E85SG6.15

101

6.15

E 85

curtain wall system


outer corner 90

90

etalbond

hard insulation 20 mm
seal 4 mm
self-drillingscrew
DIN7981 ST3.5x18-M-Z
aluminium sheet 2 mm

1
4.93

silicone seal
silicone gasket 130 705
tappingscrew
DIN7981 ST5.5x25-C-H
glazing clip 71 130

thermal insulation spacer 80 177


hard insulation 20 mm
etalbond

16

20
4

12

spacer 33 879 + 3M tape

gasket130457

89

hard insulation 40 mm
1
4.93

220

142

selfdrillingscrew
DIN7981 ST4.8x19-M-Z
L-profilesection 4065

E85SG6.16

50

41

blind rivet
DIN 7337 A4.8x8-A

not to scale
E 85 technical catalogue
01.2011

6.16

E 85

curtain wall system


inner corner 90

90

aluminium tube 7027


silicone seal
silicone gasket 130 705
thermal insulation spacer
80 171/80 183
tappingscrew
DIN7981 ST5.5x25-C-H
glazing clip 71 130
spacer 33 879

16
12 6

25.2

28
12

50

3M tape

etalbond
130

89

25.2

111
114

gasket 130 480

130

130

welded seam 3 mm

50

111

41

114

transom E 85304
flange 76 674

E85SG6.17

mullionE85104

scale 1:2
E 85 technical catalogue
01.2011

6.17

E 85

curtain wall system


inner corner 90

90

silicone seal
silicone gasket 130 705
thermal insulation spacer
80 171/80 183
glazing clip 71 130

12

16

15

130

14

28

spacer 33 879 + 3M

145
suppl.mullionprofileE85142
tappingscrew
DIN7981 ST5.5x16-C-H
gasket 130 458

E85SG6.18

41

130

89

spacer E 85640

scale 3/4
E 85 technical catalogue
01.2011

6.18

E 85

curtain wall system


silicone seal
silicone gasket 130 705
thermal insulation spaser
80 171/80 183
tappingscrew
DIN7981 ST5.5x25-C-H
glazing clip 71 130

polygonal facade with outer angle max 5

20

5
6
16

28

6 5
35

40

gasket 130 480


flange 76 661

15

10

10

15

transom E 85351
mullion E 85101

silicone seal
silicone gasket 130 705
thermal insulation spaser
80 171/80 183
tappingscrew
DIN7981 ST5.5x25-C-H

polygonal facade with inner angle max 5

16

glazing clip 71 130

41

28

19.9

35

gasket 130 480


flange 76 661

transom E 85351
3

15

10

10

15

E85SG6.19

mullion E 85101

scale 3/4
E 85 technical catalogue
01.2011

6.19

E 85

curtain wall system


conservatories vertical section

90-150

gasket 130 480


6
16

30.4

20

self-drillingscrew
DIN7981 ST4.8x19-M-Z

8.4
10

131

gasket 130 470


glazing shim 71 184
89

36
27
4 4

mullion is trimmed
etalbond

104
41

hard insulation
membrane 1 mm
etalbond
thermal insulation spacer 80 184

cut for membrane in mullion


4

28

43

F profile 31064

tappingscrew
DIN7981 ST4.2x25-C-H

20

66

131

gasket 130 473

silicone seal
silicone gasket 130 705
glazing clip 71 130
spacer 33 879

gasket 130 480


16
28

12

89

12

130

not to scale
E 85 technical catalogue
01.2011

41

E85SG6.20

6.20

E 85

curtain wall system


conservatories vertical section

115

6
30.4
16

20

8.4
10

120

184

gasket 130 470


glazing shim 71 184
89

seal 10 mm

mullion connector E 85969 below

10

16

10

64

seal 10 mm

48

20

115

99

115

41

glazing shim 71 184

silicone seal
silicone gasket 130 705
glazing clip 71 130
spacer 33 879

gasket 130 480


6

16
28

12
12

89

41
130

E85SG6.21

note:
the glass thickness should be
checked by the facade engineer

not to scale
E 85 technical catalogue
01.2011

6.21

E 85

curtain wall system


connection with rainscreen cladding system BRAVO

100

20

29

etalbond

178

207

bravo system by ETEM

E85SG6.22

gypsum board

scale 3/4
E 85 technical catalogue
01.2011

6.22

E 85

curtain wall system


connection with backing wall

etalbond
bravo system by ETEM
silicone seal
silicone gasket 130 705
thermal insulation spaser
80 171/80 183
tappingscrew
DIN7981 ST5.5x25-C-H
glazing clip 71 130
20

spacer 33 879
3M tape

12

membrane 1 mm

28
12

16

122

gasket 130 480

E85SG6.23

41

130

89

additional profile E 85612

scale 3/4
E 85 technical catalogue
01.2011

6.23

E 85

curtain wall system


bottom finishing

gasket 130 480


glazing clip 71 130
thermal insulation spacer
80 171/80 183
20

silicone seal
silicone gasket 130 705
thermal insulation spacer 80 177
additional profile E 85612

24

cut for membrane in mullion

38

etalbond

bracket 71 050

30

concrete slab
27

soft insulation 60 mm
membrane
L-profilesection 4065
self-drillingscrew
DIN7981 ST4.8x19-M-Z
seal 6 mm
plaster
perforation

E85SG6.24

hard insulation

scale 1:2
E 85 technical catalogue
01.2011

6.24

E 85

curtain wall system


facade finishing to suspended ceiling

28

12

16

6 12

130
109
spacer 33 879

21

glazing clip 71 130


gasket 130 480
flange 76 651
glazing shim 71 182

15

20

15

steel sheet 1.5 mm

thermal insulation spacer 80 177


additional profile E 85612
cut for membrane in mullion

accessory 74 674

bracket 71 270

washer DIN 440

hard insulation
membrane
concrete slab
etalbond

perforation

self-drillingscrew
DIN7981 ST4.8x19-M-Z

E85SG6.25

L-profilesection aluminum

not to scale
E 85 technical catalogue
01.2011

6.25

E 85

curtain wall system


finishing of plaster ceiling

L-profilesection 4065

60

30

self-drillingscrew
DIN7981 ST4.8x19-M-Z

etalbond

membrane

membrane

additional profile E 85612


thermal insulation spacer 80 177

15

hard insulation

76

20

33

15

bracket 71 050

transom E 85305
mullionE85104
gasket 130 480
16
28

12

109

12

130
170

scale 3/4
E 85 technical catalogue
01.2011

21

6.26

E85SG6.26

E 85

curtain wall system


etalbond spandrel panel in brustung zone
170

28

12

16

6 12

130
109

21

spacer 33 879
glazing clip 71 130
gasket 130 480
flange 76 651
glazing shim 71 182
transom E 85305
steel sheet 2 mm
self-drillingscrew
DIN7981 ST4.8x16-M-Z
self-drillingscrew
DIN7981 ST4.8x19-M-Z

thermalinsulationspacer80177

20
4

60
4

28

60
88

etalbond

soft insulation

bracket 71 272

washer DIN 440

steel sheet 2 mm
self-drillingscrew
DIN7981 ST4.8x16-M-Z

mullionE85104
transom E 85305

E85SG6.27

thermalinsulationspacer80177

not to scale
E 85 technical catalogue
01.2011

6.27

E 85

curtain wall system


upper finishing with etalbond

10

1
4.23

20

110

1
4.23

glazing clip 71 130


gasket 130 480
6

16

6 12

109

28

12

130

21

40
40

170
soft insulation

340

gypsum board

min 30

bracket 71 270

20

washer DIN 440

transom E 85305

not to scale
E 85 technical catalogue
01.2011

6.28

E85SG6.28

mullionE85104

COMBINATIONS
SECTIONS

DETAILS

E 85

curtain wall system


combined facade with vertical cap and horizontal silicone joint

tappingscrew
DIN7981 ST5.5x45-C-H

50
15

10

10

15

cover cap E 85713

20

butyl seal 133 553


gasket130500

16
12

min 6

gasket 130 473

28
12

6 5

25

pressureplateE85700

gasket 130 480


thermalinsulationspacer80172

195.2

gasket 76 651
5

flange 76 674

89

tappingscrew
DIN7981 ST4.8x19-C-H
3

130

15
18

10

10
20

15

18
fixing part 71 113

transom E 85304
6
41

mullionE85104

E85K7.1

50

scale 3/4
E 85 technical catalogue
01.2011

7.1

E 85

curtain wall system


combined facade with vertical cap and horizontal silicone joint

spacer 33 879
glazing clip 71 130
gasket 130 463
glazing shim 71 185

15

flange 76 664

56.3

50
5

min 6

tappingscrew
DIN7981 ST5.5x25-C-H

min 6

15

10

20

10

thermal insulation spaser


80 171/80 183

fixingpart71113
transomE85354
6

silicone flange 76 680 behind


silicone gasket 130 705
silicone seal
mullion E 85104

25

5 6

16
28

12

89

12

130

scale 3/4
E 85 technical catalogue
01.2011

41

E85K7.2

20

7.2

E 85

curtain wall system


combined facade with vertical cap and horizontal silicone joint
with projected thermo-break window

gasket 130 706

tappingscrew
DIN7981 ST5.5x45-C-H

50

gasket130479

33

glass support E 85615

14.4

14.2
45.8

10.8

10

15

cover cap E 85713


pressureplateE85700

gasket 130 131


gasket130500

gasket 130 473


16
28

31

16
6

6
9

gasket 130 176 / P6

12

16

28
7

norton tape 6x6.4 mm

25

butyl seal 133 553

structural seal 6 mm

gasket 130 480

56

sash E 85210
spacer 700R
gasket 130 461
friction arm 400R/600R
operating rod E 2308
striker 255 602
striker 255 603
gasket 130 180
frame E 85410

38.2

20

38.5

15
18

10

10
20

3
15
18

79.2

transom E 85304

50

scale 3/4
E 85 technical catalogue
01.2011

7.3

E85K7.3

41

mullionE85104

E 85

curtain wall system


combined facade with vertical cap and horizontal silicone joint
with 3rd level transom and projected thermo-break window

6
6

16
6

56

38.2
gasket 130 176 / P6

16

sash E 85210
gasket 130 461

20

norton tape 6x6.4 mm

operating rod E 2308


self-drillingscrew
DIN7981 ST4.8x32-M-Z
gasket 130 180

structural seal 6 mm

striker 255 602


striker 255 603

38.5

glass support E 85614

55.5

gasket 130 473

gasket 130 707

frame E 85410

16

50

1.6

20.8

glazing shim 71 185

min 6

glazing clip 71 130


thermal insulation spaser
80 171/80 183

min 6

15

33.3

2
7.9

14

transomE85354

flange 76 664
fixing part 71 113
gasket 076 651 behind
gasket 130 463

1.1

silicone gasket 130 705


silicone seal
mullion E 85104

25

5 6

16
28

89

12

130

scale 3/4
E 85 technical catalogue
01.2011

41

E85K7.4

20

7.4

E 85

curtain wall system


combined facade with vertical silicone joint and horizontal cap

10

spacer 33 879

min 6

15
16
12

15

tape

min 6

28
12

20
10

6 5

20

15

silicone seal
silicone gasket 130 705
thermal insulation spaser
80 171/80 183
tappingscrew
DIN7981 ST5.5x25-C-H
glazing clip 71 130

gasket 130 480


gasket 76 651
flange 76 674
5

tappingscrew
DIN7981 ST4.8x19-C-H

89

3
130

15
18

10

10
20

15

18
fixing part 71 113

transom E 85304
6
41

mullionE85104

E85K7.5

50

scale 3/4
E 85 technical catalogue
01.2011

7.5

E 85

curtain wall system


combined facade with vertical silicone joint and horizontal cap

cover cap E 85712


pressureplateE85700
gasket130500
butyl seal 133 553
tappingscrew
DIN7981 ST5.5x45-C-H
gasket 130 463

56.3

50
15

10

50

10

15

glazing shim 71 185

flange 76 664
fixing part 71 113
transomE85354
silicone flange 76 680 behind
thermalinsulationspacer80172
PVCspacer9020
mullion E 85104
28
6

16

6
6

89

12

130

scale 3/4
E 85 technical catalogue
01.2011

41

E85K7.6

20

7.6

E 85

curtain wall system


combined facade with vertical silicone joint and horizontal cap
with parallel opening thermo-break window

silicone seal
silicone gasket 130 705

33.3

glass support E 85614


gasket 130 707

55.5

tappingscrew
DIN7981 ST5.5x25-C-H
glazing clip 71 130

20.8

gasket 130 479

spacer 33 879

16
6

9.2

16

28
7

min 6

15
6 5

20

structural seal 6 mm
norton tape 6x6.4 mm

gasket 130 176


sash E 85211

gasket 130 480

56

gasket 130 461


friction arm 900R/900L
operating rod E 2308
6

gasket 130 180


frame E 85410

2
38.5

14
16

11

10
21

15

18

41

transom E 85304

8
79.2

38.2

20

mullionE85104

E85K7.7

50

scale 3/4
E 85 technical catalogue
01.2011

7.7

E 85

curtain wall system


combined facade with vertical silicone joint and horizontal cap
with 3rd level transom and parallel opening thermo-break window

gasket 130 176


20

sash E 85211
norton tape 6x6.4 mm

gasket 130 461


operating rod E 2308
self-drillingscrew
DIN7981 ST4.8x32-M-Z
gasket 130 180

gasket 130 131

33

structural seal 6 mm

friction arm 900R/900L

38.5

gasket 130 706

frame E 85410

45.8

14.4

transom E 85304

36

50

gasket 130 473


31

gasket 130 473

glazing shim 71 185

gasket 130 463


thermalinsulationspacer80172

gasket130500
6

16

12

89

scale 3/4
E 85 technical catalogue
01.2011

41

E85K7.8

20

7.8

E 85

curtain wall system


anti-burglar system
mullion with 2nd level transom

143 906
143 907
cover cap E 8700

60

50 009
pressureplateE8620

gasket130500

10

25

61

butyl seal 133 553

23

B2310 (P5A)

thermal insulation spacer 80 171


gasket 130 458
gasket 76 651
tube 47 001
143 905

89

71 221

130

191

71 218
71 228
flange 76 674
transom E 85304

41

mullionE85104

E85K7.9

50

scale 3/4
E 85 technical catalogue
01.2011

7.9

E 85

curtain wall system


anti-burglar system
transom 2nd level drainage

B2310 (P5A)
cover cap E 8701
pressureplateE8620
gasket130500
butyl seal 133 553
thermal insulation spacer 80 171
gasket 130 458
flange 76 674

143 906
143 907

56.3

50

60

71 221

71 218

glazing shim 71 182


10

transomE85304
gasket 076 651 behind
50 009
mullion E 85104

23

23

89

61

41
130

E85K7.10

191

scale 3/4
E 85 technical catalogue
01.2011

7.10

MACHININGS
MACHINING

PROCESSING

E 85

curtain wall system


cutting lengths

transom
pressure plate

E85M8.1

cover cap

not to scale
E 85 technical catalogue
01.2011

8.1

E 85

curtain wall system


machinings of transom 2nd level drainage with spring t-joint and flange

mullion

A
flange
12
fixing part 71 113

transom
18

15

gasket 76 651
DIN7981 ST4.8x19-C-H

additional machining of transom for the spring t-joint


flange
76671
76672
76673
76674
76675
76676
76677

A mm
---78,5
98,5
118,5
148,5

E85M8.2

transom
E 85301
E 85302
E 85303
E 85304
E 85305
E 85306
E 85307

not to scale
E 85 technical catalogue
01.2011

8.2

E 85

curtain wall system


machinings of transom 3rd level drainage with spring t-joint and flange

mullion

flange
12
fixing part 71 113

transom
18

silicone flange 76 680


tappingscrew
DIN7981 ST4.8x19-C-H

flange
76660
76661
76662
76663
76664
76665
76666
76667
76668
76669

A mm
---58,5
78,5
98,5
118,5
148,5
168,5
188,5

additional machining of transom for the spring t-joint

E85M8.3

transom
E 85360
E 85351
E 85352
E 85353
E 85354
E 85355
E 85356
E 85357
E 85358
E 85359

not to scale
E 85 technical catalogue
01.2011

8.3

E 85

curtain wall system


machinings of transom 2nd level drainage with T-joint and flange

mullion

flange

T-joint

transom
18

15
gasket 76 651
tappingscrew
DIN7981 ST4.8x19-C-H

flange
76672
76673
76674
76675
76676
76677

T-joint
71122
71123
71124
71125
71126
71127

E85M8.4

transom
E 85302
E 85303
E 85304
E 85305
E 85306
E 85307

not to scale
E 85 technical catalogue
01.2011

8.4

E 85

curtain wall system


machinings of transom 2nd level drainage with T-joint and flange

mullion

flange

T-joint

18

transom

6
silicone flange 76 680
tappingscrew
DIN7981 ST4.8x19-C-H

flange
76661
76662
76663
76664
76665
76666
76667
76668
76669
76670

T-joint
71131
71132
71133
71134
71135
71136
71137
71138
71139
71144

E85M8.5

transom
E 85351
E 85352
E 85353
E 85354
E 85355
E 85356
E 85357
E 85358
E 85359
E 85369

not to scale
E 85 technical catalogue
01.2011

8.5

E 85

curtain wall system


machinings of transom 2nd level drainage with transom connectors

7 6.5

15

5
mullion

15
20

46

17

15

flange

T-joint

17

transom

15
gasket 76 651
tappingscrew
DIN7981 ST4.8x19-C-H

flange
76622
76623

T-joint
71152
71153

E85M8.6

transom
E 85302
E 85303

not to scale
E 85 technical catalogue
01.2011

8.6

E 85

curtain wall system


machinings of transom 3rd level drainage with transom connectors

7
6

5
mullion

6.5

15
20

46

17
8

15

flange

T-joint

transom

17

silicone flange 76 680


tappingscrew
DIN7981 ST4.8x19-C-H

flange
76624
76625

T-joint
71141
71142

E85M8.7

transom
E 85351
E 85352

not to scale
E 85 technical catalogue
01.2011

8.7

E 85

curtain wall system


machinings of transom 2nd level drainage with reinforcement
T-joint 71 140
66
.5
1 0

22.8

22

87

46

mullion
4

19
flange 76 676

12

69
87

44
16

T-joint 71 140

set 71 219
set 71 218
14

12
gasket 76 651

53

15.5

tappingscrew
DIN7981 ST4.8x19-C-H

18

45
12

reinforcement 85 801

53

15
31

reinforcement 71 187

4 .2

transom 85306
reinforcement 71 187

20

80

92
100

DIN 7981 4.8x19

additional
reinforcement 71 186 /optional/

DIN 7981 5.5x38


4 .2

12

74

100

12

note:
In case of 2nd level transom, glazing shim reinforcement should be placed before connecting transom and mullion.
Additional reinforcement 71 186 has to be used in case of thicker glazings.

not to scale
E 85 technical catalogue
01.2011

8.8

E85M8.8

14

E 85

curtain wall system


machinings of transom 3rd level drainage with reinforcement
T-joint 71 143
96

22
22.8

10.5

132
1
2

14

mullion

flange 76 677
74

19

114
132

16
T-joint 71 143

set 71 219
set 71 218
14

12

silicone flange 76 680

98

15.5

tappingscrew
DIN7981 ST4.8x19-C-H

45
18

reinforcement E 85802

98

22

DIN 7981 5.5x38


reinforcement 71 188

4.2

12

4.2

transom 85357
reinforcement 71 188

20

80

additional
reinforcement 71 186 /optional/

DIN 7981 4.8x19

92
100

additional reinforcement 71 186


5
14

12

74

100

12

note:
Additional reinforcement 71 186 has to be used in case of thicker glazings.

not to scale

E 85 technical catalogue
01.2011

8.9

92
100

E85M8.9

E 85

curtain wall system


fixing of 3rd level transom using transom connector E 85994 at angle 90

mullion

a = 0 ~ 60
X=

butyl seal
76 681 between
mullion and transom

(D-20) + 50 x sin(a)
cos(a)

transom connector E 85994

tappingscrew
DIN7981 ST4.8x19-C-H

a
tappingscrew
DIN7981 ST4.8x19-C-H

b
tappingscrew
DIN7981 ST4.8x38-C-H

transom
90-a

b, mm
25
45
43
63
83
103
133
153
173
224

E85M8.10

transom
E 85351
E 85352
E 85353
E 85354
E 85355
E 85356
E 85357
E 85358
E 85359
E 85369

not to scale
E 85 technical catalogue
01.2011

8.10

E 85

curtain wall system


transom connector E 85994
83.15

68.55
57.2
48.0
40.3
33.6
27.7
22.4

Fixing devices have to


be placed coaxially
even though transoms
are not parallel.

Distance between
fixing devices must be
evaluated according to
the following diagram,
so that to achieve
smooth transition of
the external webs of
every transom

17.5
12.9
8.5
4.2
0.0
5 10 15 20 25 30 35 40 45 50 55 60

a()

a = 0 ~ 60

Capability of fastening
transom by screws on the
frontal face of fixing device

In order to achieve optimum result in terms of aesthetics, the


axis of the rotated transom must always be in accordance to
the diagram above,depending on the angle of rotation, so that
the centre of rotation of the transom is at the intersection of
the axes of rotated and non rotated transoms

not to scale
E 85 technical catalogue
01.2011

8.11

E85M8.11

90-a

E 85

curtain wall system


connection between transom E 85300 and supplementary transom to mullion
supplementary
transom
E
E
E
E

10

85600
85601
85602
85603

flange
76650
76652
76653
76654

100

supplementary transom

76 650

not to scale
E 85 technical catalogue
01.2011

tappingscrew
DIN7981 ST4.8x19-C-H

8.12

E85M8.12

tappingscrew
DIN7982 ST4.8x19-C-H

H 120

H 120

H 120

8.13

E85M8.13

L1
05

52

L1
50

L1
05

52

52

71 150

71 120

71 207

H 90

H 90

H 90

10
B2

58
B1

L1
05

20
B 2 L 10
5

52

L1
50

52

52

71 159

71 290

71 090

H 115
H 115
H 115

10
B2

58
B1

20
B2

L1
06

52

L1
50

L1
05

53

52

71 250

71 015

71 270

H 72
H 72
H 72

E 85 technical catalogue
01.2011
10
B2

58
B1

20
B2

L1
06

L1
05

L1
50

51.8

52

71 572

71 390

movable support

fixed support

53

71 072

H 65
H 65

not to scale
H 65

L1
06

20
L1
B2
05

10
B2

58
B1

52

L1
50

52

71 265

53

71 565

71 065

fixing brackets

10
B2

58
B1

20
B2

curtain wall system

E 85

E 85

curtain wall system


fixing brackets

L1
05

71 121

71 091

4
B8

L1
05

H 90

H 120

4
B8

4
B8

L1
05

71 172

71 372

L1
05

H 72

H 115

4
B8

71 165

L1
05

H 65

4
B8

fixed support

120

min

E85M8.14

H/2

movable support

not to scale
E 85 technical catalogue
01.2011

8.14

E 85

curtain wall system


anchoring elements for fixing brackets
set for movable support
71 212 - for systems 85

nut M10
washer 71 208 from profile 85901
bush 15x63
washer 71 208 from profile 85901
washer 10
bolt M10x100

anchor for concrete


(set with washer and nut)
07M12123S

movable support

washer 71 208 from profile 85901

anchor for concrete 07M12123S


(set with washer and nut)

anchor 12123
washer 12
nut M12

fixed support
washer 71 208 from profile 85901

set for fixed support


71 211 - for systems 85

nut M10
washer 71 208 from profile 85901
bush 15x51
washer 71 208 from profile 85901
washer 10

E85M8.15

bolt M10x100

not to scale
E 85 technical catalogue
01.2011

8.15

E 85

curtain wall system


simply supported beams
anchor for concrete
(set with washer and nut)
07M12123S
B

movable
support
bolt M10x100

anchor for concrete


(set with washer and nut)
07M12123S

bush 15x51

fixed
support

not to scale
E 85 technical catalogue
01.2011

bolt M10x100

E85M8.16

bolt M10x100

8.16

E 85

curtain wall system


beam supported at three points
anchor for concrete
(set with washer and nut)
07M12123S

B
B

bolt M10x100
movable
support

anchor for concrete


(set with washer and nut)
07M12123S

movable
support

bolt M10x100
anchor for concrete
(set with washer and nut)
07M12123S

bush 15x51

fixed
support

not to scale
E 85 technical catalogue
01.2011

bolt M10x100

E85M8.17

bolt M10x100

8.17

E 85

curtain wall system


fixing brackets

43
.2

71 050 or
E 85913 profile

43.
2

H 140

E 85918
profile

H 90

nut 12 washer 12

B2
20

B2
10

anchor 12123
DIN 440

set for bracket as a hidden


support 71 213

anchor M12x123

nut 10
bush 15x50 / 2pc.
washer 10
bolt 10x70

120

min

120

min

min

120

120

note:
accessories from profiles E 85913 and E 85918 can be produced and delivered
with the machinings, after ordering and specifing the mullion.
not to scale
E 85 technical catalogue
01.2011

8.18

E85M8.18

H/2

min

120

min

E 85

curtain wall system


combinations and machinings

30
4
movable support

30

mullion

cut for membrane

insert

30
mullion

fixed support

35

11
M10x150

membrane
8

10

bar 50x8 mm

20

18

50

bar 50x8 mm

transom
E 85102
E 85103
E 85104
E 85105
E 85106
E 85107
E 85108

not to scale
E 85 technical catalogue
01.2011

8.19

insert
E 85952
E 85953
E 85954
E 85955
E 85956
E 85957
E 85958

A, mm
96,0
116,0
136,0
166,0
183,5
203,5
200,5

B, mm min
38,4
58,4
78,4
108,4
123,9
143,9
134,9

C, mm min
29,6
29,6
29,6
29,6
31,6
31,6
37,6

E85M8.19

M8x40

E 85

curtain wall system


connection between two mullions with insert
- The joint of the cover caps must be at least 50 mm lower
than the joint of the pressure plates, which in turn must be 50
mm lower than the joint of the mullions

tappingscrew
DIN7981 ST2.9x6.5-C-H

- The screws used for fastening the drainage devices must


not be longer than 8 mm so that dilatation is not impaired. The
drainage devices MUST always be fastened on the upper
mullion and the fixing openings as the contact area only on the
upper mullion is sealed with silicone (*).

71 209 (kit)

ST 2,9

Put silicone on
the upper surface

The joint between


mullions is sealed
with silicone
shaped INOX or
aluminium sheet (1mm)

Rectangular standard
profile 40x4 mm
anchored in the middle
of the stiffener by
plastic deformation of
the tracks

ATTENTION:
The cutting length of the
horizontal pressure plate must
not be less than (L-55)

L (Distance between axes)

ATTENTION:
Do not use a screw with greater size than the recommended,
because it has to be covered by the horizontal cover cap
(shortest cover cap E-85711 - 12mm)

27.5

not to scale
E 85 technical catalogue
01.2011

8.20

L - 55
L - 51

E85M8.20

ST 2,9

E 85

curtain wall system


transom to transom connection

not to scale
E 85 technical catalogue
01.2011

8.21

E85M8.21

E 85

curtain wall system


condensation water drainage
water drainage

max 8 m

max 8 m

max 8 m

*upside down

fill with silicone here

30

50

drainage profile 74 674

12
pressure plate

not to scale
E 85 technical catalogue
01.2011

8.22

E85M8.22

drainage profile 74 674

E 85

curtain wall system


bottom finishing

cut for membrane


mullion
mullion
27 4

transom

add. profile E 85612

cut for membrane in mullion

bracket 71 050

concrete slab

E85M8.23

membrane

not to scale
E 85 technical catalogue
01.2011

8.23

E 85

curtain wall system


fixing of transom E 85320

part of gasket 76 651

tappingscrew
DIN7981 ST2.9x6.5-C-H
a

36

tappingscrew
DIN7981 ST4.8x19-C-H
part of gasket 76 651

a
16

accessory 74 674
transom E 85320

membrane

a = 30 ~ 83

not to scale
E 85 technical catalogue
01.2011

8.24

aluminium sheet

gasket 130 199

E85M8.24

ATTENTION:
- drainage fitting from profile E 85 991 has to be cut on angle a for each project
- accessory 74 674 must be inserted before assembly of mullions
- accessory 74 674 must be filled with silicone after fixing to mullion

E 85

curtain wall system


fixing of transom E 85370

6
tappingscrew
DIN7981 ST2.9x6.5-C-H

cut from profile 85 911

transom E 85370
a

accessory 74 674

suppl. profile E 85670

tappingscrew
DIN7981 ST4.8x19-C-H

membrane

silicone flange 76 680


6
16

ATTENTION:
- drainage fitting from profile E 85 991 has to be cut on angle a for each project
- accessory 74 674 must be inserted before assembly of mullions
- accessory 74 674 must be filled with silicone after fixing to mullion
transom E 85370

not to scale

E 85 technical catalogue
01.2011

8.25

E85M8.25

a = 0 ~ 83

E 85

curtain wall system


roof connection of two mullions using E 85960

ATTENTION:
Fasteners, washers, spring
washers etc, must be made of
stainless steel A2.

B = 25mm (min)
C = B - 4,5mm

article has to be cut at two


points at the peak
axis of measuring angles

M6

M6

Grooves for
TIG-MIG
weldment

C
M8
M8
A

ATTENTION:
Welding is
compulsory

note:
The number of sets 71 216 needed has to be
determined by the facade engineer taking into
consideration the applied loads in each specific case.

A, mm
38
58
78
98
128

B, min mm
25
25
25
25
25

C, min mm
20,5
20,5
20,5
20,5
20,5

E85M8.26

transom
E 85101
E 85102
E 85103
E 85104
E 85105

not to scale
E 85 technical catalogue
01.2011

8.26

E 85

curtain wall system


roof connection of two mullions using E 85969
a

ATTENTION:
Fasteners, washers, spring
washers etc, must be made of
stainless steel A2.
B = Cmin+X

X thickness of wall

article has to be cut at two


points at the peak
axis of measuring angles

spring pin 5x40

nut M6

cap head bolt M6x50


12
12

grooves for
TIG-MIG
weldment

underlay washer 8
A
bush M8x50

countersunk bolt M8x25

ATTENTION:
welding is
compulsory

note:
all fixings are included in set 71 216
for roof connection
A, mm
182

B, mm min
35,5

C, mm min
20,5

E85M8.27

transom
E 85109

not to scale
E 85 technical catalogue
01.2011

8.27

E 85

curtain wall system

23.8

23.8

14.5

machinings

20

10

15

30

2.5

5.5 5

63

5.5 5

10

2.5

25

20

180~240

not to scale
E 85 technical catalogue
01.2011

8.28

every 180~240

E85M8.28

every 180~240

25

ATTENTION:
Apart from the submarginal drainage holes which have to be opened in any case
both on the pressure plate and cover cap, additional holes have to be opened in
the middle, in case that the length of the transom is greater than 1.25 m or if the
surface of the glass pane is greater than 2 m

E 85

curtain wall system


water drainage with 2nd level transom

B
A
B

B-B
28

34

thermalinsulationspacer80172

thermalinsulationspacer80172

gasket 130 474


water drainage

water drainage

A-A

150

150

note:
1. In case of 2nd level drainage, it is obligatory to use 150 mm butyl seal tape in both directions of the cross zone.
2. In case of roof constructions, conservatories, facades with inclinations and polygonal facades with 2nd level drainage, it is
obligatory to use butyl seal tape in both directions.

not to scale
E 85 technical catalogue
01.2011

8.29

E85M8.29

butyl seal 133 553

E 85

curtain wall system


fixing of E 85723 to E 85745
pressure plate E 85700
pressure plate E 85745

cap E 85713
cap E 85723

tappingscrew
DIN7981 ST3.5x13-C-H

E85M8.30

note:
all big cover caps (E 85723, E85724, E85716, E85718) have
to be used with pressure plate E85745 and to
be fastened with screws

not to scale
E 85 technical catalogue
01.2011

8.30

E 85

curtain wall system


assembling of spacer for structural glazing

B-B
1

positions
W1
120
71 130

4
inside

28
X

71 130

120

250

min 16

17

71 130

glazing clip 71 130

71 130

71 130

glazing shim 71 185

H3

H1

71 130

6
spacer 33 879

71 130

24

min 100

W3
120

250

outside

A-A

silicone gasket 130 705


glazing clip 71 130

thermal insulation spacer 80 171


71 130

71 130

20
6

71 130

71 130

100
250

100

B
120

glazing shim

glazing shim

40.2

28

71 130

16

min 100

spacer 33 879

120

120

250
12.2

W3
W1
X = 250 ~ 300 mm (depends of
overall dimentions and wind load)

cutting of spacer
width of spacer
height of spacer

W1 = W2 34
H1 = H2 34

cutting of spacer 33 879


W3 = W1
width of spacer
H3 = H1 200
height of spacer
235
300
150
100

100

glazing clip 71 130


160

glazing shim

E85M8.31

thermal insulation spaser 80 183

not to scale
E 85 technical catalogue
01.2011

8.31

E 85

curtain wall system


structural glazing assembly

mullion
gasket

thermal insulation spacer 80 171

glazing clip 71 130


tappingscrew
DINISO7050 ST5.5x22-C-H
thermal insulation spacer 80 183

E85M8.32

spacer 33 879

not to scale
E 85 technical catalogue
01.2011

8.32

E 85

curtain wall system


projected window fixings and machinings
E 85410

E 85210

29.5

12

5.6

9.6

10.5
19
6
20

scale 1:2

4.5

scale 1:2

40.1

13

40.1

19

13

10.5

20.3

54 302
54 457

54 462

54 302

54 462

not to scale
E 85 technical catalogue
01.2011

8.33

E85M8.33

54 457

E 85

curtain wall system

E85M8.34

machining of drainage opening

not to scale
E 85 technical catalogue
01.2011

8.34

E 85

curtain wall system


machining of glass support E 85615

glass support E 85615

glass support E 85615

45

note:
glazing support E 85615 is stocked in
color RAL 9005

not to scale
E 85 technical catalogue
01.2011

glass support E 85615

8.35

E85M8.35

tappingscrew
DIN7982 ST3.5x13-C-H

90

45

structural glazing silicone

E 85

curtain wall system


machining of glass support E 85614

glass support E 85614

glass support E 85614

45

90

45

structural glazing silicone

tappingscrew
DIN7982 ST3.5x13-C-H

note:
glazing support E 85614 is
stocked in color RAL 9005

not to scale
E 85 technical catalogue
01.2011

8.36

E85M8.36

glass support E 85614

E 85

curtain wall system


profiles for projected window
glass support E 85615
glass support E 85614

glass support E 85614


structural glazing silicone

glass support E 85615


structural glazing silicone

tappingscrew
DIN7982 ST3.5x13-C-H

E85M8.37

tappingscrew
DIN7982 ST3.5x13-C-H

not to scale
E 85 technical catalogue
01.2011

8.37

E 85

curtain wall system

note:
cutting of EPDM 130 706 and 130 707 has to be performed with patterns 990 522 and 130 521

not to scale
E 85 technical catalogue
01.2011

8.38

E85M8.38

required machinings of gaskets 130 706 and 130 707 for


projected window used in two sided curtain wall

E 85

curtain wall system


projected opening window

800R - set of nuts


for 400R and 600R
blind rivet nut M5 - 14 pcs

screw M5x16 - 6 pcs

countersunk screw M5x20 - 8 pcs

arm for projected window


type

length, mm

400 R
600 R

adjustable
adjustable

405
665

angle of
opening,
25
15

height of
frame, mm
500-1200
1201-2000

load, kg

E85M8.39

code

80
130

not to scale
E 85 technical catalogue
01.2011

8.39

E 85

curtain wall system

E 85 technical catalogue
01.2011

8.40

E 85

curtain wall system


etalbond and glass panels

E 40956 (11mm)
etalbond

E-85291
silicone gasket 130 705

E-85290

etalbond

not to scale
E 85 technical catalogue
01.2011

ATTENTION:
protection membrane from etalbond
has to be put before sealing the
structural joint with silicone.

etalbond

8.41

E85M8.41

etalbond

E 85

curtain wall system


etalbond panels

L = distance between mullion axes


D = distance between transom axes

L-20
E 40956 (18.2mm)

50

50
etalbond
E 85290
** Groove accepts self
adhesive tape (10mm).

25

L-20*
ATTENTION:
cutting dimensions of panel
are for 4mm etalbond.

E85M8.42

* correction because of
etalbond cassette making.

not to scale
E 85 technical catalogue
01.2011

8.42

ACCESSORIES
IMAGES

DESCRIPTIONS

code/description

package/pcs

ET071207

colour

MF

fixing bracket 120 mm

ET071090

MF

fixing bracket 90 mm

ET071120

MF

MF

fixing bracket 120 mm

ET071290

fixing bracket 90 mm

E 85 technical catalogue
01.2011

9.1

mullion

code/description

package/pcs

ET071150

colour

MF

MF

MF

MF

fixing bracket 120 mm

ET071159

fixing bracket 90 mm

ET071270

fixing bracket 115 mm

ET071072

fixing bracket 72 mm

E 85 technical catalogue
01.2011

9.2

code/description

ET071265

package/pcs

colour

MF

MF

MF

MF

fixing bracket 65 mm

ET071015

fixing bracket 115 mm

ET071390

fixing bracket 72 mm

ET071065

fixing bracket 65 mm

E 85 technical catalogue
01.2011

9.3

code/description

package/pcs

ET071250

colour

MF

MF

MF

MF

fixing bracket 115 mm

ET071572

fixing bracket 72 mm

ET071565

fixing bracket 65 mm

ET071121

fixing bracket 120 mm

E 85 technical catalogue
01.2011

9.4

code/description

ET071091

package/pcs

colour

MF

MF

MF

MF

fixing bracket 90 mm

ET071172

fixing bracket 115 mm

ET071372

fixing bracket 72 mm

ET071165

fixing bracket 65 mm

E 85 technical catalogue
01.2011

9.5

code/description

package/pcs

ET071050

colour

MF

hidden fixing bracket 50 mm

ET071211

MF

set for bracket as a fixed support

ET071212

MF

MF

set for movable support

ET071213

set for hidden fixed support

E 85 technical catalogue
01.2011

9.6

code/description

package/pcs

ET071216

colour

MF

MF

MF

MF

set for roof connector

ET071218

set for reinforced T-joint

ET071219

fixing set transom mullion

ET071208

washer

E 85 technical catalogue
01.2011

9.7

code/description

package/pcs

colour

MF

DIN440

washer

MF

100

MF

07M12123S

galvanized anchor M12x123

DIN 7981

tapping screw ST4.8x19-C-H


ST4.8x25-C-H
ST5.5x19-C-H
ST5.5x25-C-H
ST5.5x32-C-H
ST5.5x38-C-H
ST5.5x45-C-H

DIN 7982

100

MF

tapping screw ST3.5x13-C-H


ST4.8x19-C-H
ST5.5x25-C-H

E 85 technical catalogue
01.2011

9.8

code/description

package/pcs

ET071209

50

colour

MF

drainage fitting between mullions

ET074674

50

drainage for mullion

ET074657

50

plastic plug for profile


E85723

ET076651

50

EPDM flange between


mullion and transom
2nd level drainage

E 85 technical catalogue
01.2011

9.9

code/description

package/pcs

ET076680

colour

200

seal between mullion


and transom
3rd level drainage

ET076681

6m

butyl seal between mullion


and transom III level drainage

ET071113

100

MF

fixing part between transom


and mullion with spring

ET076671

800

PVC flange for transom

-85 301
E 85 technical catalogue
01.2011

9.10

code/description

package/pcs

ET076672

colour

600

PVC flange for transom

-85 302

ET076673

600

PVC flange for transom

-85 303

ET076674

400

PVC flange for transom

-85 304

ET076675

350

PVC flange for transom

-85 305
E 85 technical catalogue
01.2011

9.11

code/description

package/pcs

ET076676

colour

440

PVC flange for transom

-85 306

ET076677

400

PVC flange for transom

-85 307

ET076660

100

PVC flange for transom

-85 360

ET076661

100

PVC flange for transom

-85 351
E 85 technical catalogue
01.2011

9.12

code/description

package/pcs

ET076662

colour

100

PVC flange for transom

-85 352

ET076663

100

PVC flange for transom

-85 353

ET076664

100

PVC flange for transom

-85 354

ET076665

100

PVC flange for transom

-85 355
E 85 technical catalogue
01.2011

9.13

code/description

package/pcs

ET076666

colour

100

PVC flange for transom

-85 356

ET076667

100

PVC flange for transom

-85 357

ET076668

100

PVC flange for transom

-85 358

ET076669

100

PVC flange for transom

-85 359
E 85 technical catalogue
01.2011

9.14

code/description

package/pcs

ET076670

colour

100

PVC flange for transom

-85 369

ET076622

200

L type flange for ET071152


for transom

-85 302

ET076623

200

L type flange for ET071153


for transom

-85 303

ET076624

200

L type flange for ET071141


for transom
-85 351
E 85 technical catalogue
01.2011

9.15

code/description

ET076625

package/pcs

colour

200

L type flange for ET071142


for transom

-85 352

ET071122

300

MF

T-joint for transom

-85302

ET071123

350

MF

T-joint for transom

-85303

ET071124

280

MF

T-joint for transom


-85304
E 85 technical catalogue
01.2011

9.16

code/description

ET071125

package/pcs

200

colour

MF

T-joint for transom

-85305

ET071126

170

MF

T-joint for transom

-85306

ET071127

140

MF

T-joint for transom

-85307

ET071131

320

MF

T-joint for transom

-85351
E 85 technical catalogue
01.2011

9.17

code/description

ET071132

package/pcs

300

colour

MF

T-joint for transom


-85352

ET071133

280

MF

T-joint for transom

-85353

ET071134

210

MF

T-joint for transom

-85354

ET071135

180

MF

T-joint for transom

-85355
E 85 technical catalogue
01.2011

9.18

code/description

ET071136

package/pcs

156

colour

MF

T-joint for transom

-85356

ET071137

110

MF

T-joint for transom

-85357

ET071138

100

MF

T-joint for transom

-85358

ET071139

96

MF

T-joint for transom

-85359
E 85 technical catalogue
01.2011

9.19

code/description

package/pcs

ET071144

50

colour

MF

T-btacket for transom 85369

-85369

ET71140

100

MF

reinforced T-joint 105 mm


for transom 85 306
2nd level drainage

ET71143

80

MF

250

MF

reinforced T-joint 150 mm


for transom 85 357
3rd level drainage

ET071152

complex fixing part


for transom
-85302
E 85 technical catalogue
01.2011

9.20

code/description

ET071153

package/pcs

150

colour

MF

complex fixing part


for transom

-85303

ET071141

300

MF

complex fixing part


for transom
-85351

ET071142

150

MF

complex fixing part for transom

-85352

E 85 technical catalogue
01.2011

9.21

code/description

package/pcs

ET071130

100

colour

MF

fixing part for structural


glazing 60 mm

ET071109

200

MF

double fixing part combined


with glazing bead E85990

ET071110

100

MF

single fixing part combined


with glazing bead 85990

ET071180

500

MF

aluminium glazing shim


26.5 mm for transoms
3rd level drainage

E 85 technical catalogue
01.2011

9.22

frame

code/description

package/pcs

ET071181

colour

200

MF

200

MF

350

MF

aluminium glazing shim


36.5 mm for transoms
3rd level drainage

ET071185

aluminium glazing shim


30 mm for transoms
3rd level drainage

ET071182

aluminium glazing shim


32 mm for transoms
2nd level drainage

ET071183

300

MF

aluminium glazing shim


41 mm for transoms
2nd level drainage

E 85 technical catalogue
01.2011

9.23

code/description

package/pcs

ET071184

colour

350

MF

200

MF

aluminium glazing shim


36 mm for transoms
2nd level drainage

ET071186

additional aluminium glazing shim for


heavy glass panels

ET071187

100

MF

aluminium glazing shim for heavy


glass panels, for transom
2nd level drainage

ET071188

100

MF

aluminium glazing shim for heavy


glass panels, for transom
3rd level drainage

E 85 technical catalogue
01.2011

9.24

code/description

package/pcs

ET053302

250

colour

projected window

MF

die custd aluminium


joint corner bracket

-85410

ET054457

180

MF

extruded aluminium joint


corner bracket 35,8 mm
-85410

ET054459

200

MF

extruded aluminium joint


corner bracket 15,6 mm
-85200

ET054458

250

MF

extruded aluminium joint


corner bracket 17,2 mm
-85400

E 85 technical catalogue
01.2011

9.25

code/description

package/pcs

ET054461

100

colour

MF

extruded aluminium joint


corner bracket 40 mm

-85210

-85211

ET054462

300

MF

extruded aluminium joint


corner bracket 3.5 mm

-85210

-85211

E 85 technical catalogue
01.2011

9.26

code/description

ET130473

package/pcs

colour

80

EPDM gasket
for glazing 3 mm

ET130474

100

EPDM gasket for


glazing 4 mm

ET130462

100

EPDM gasket for


glazing 4 mm

ET130455

100

EPDM gasket for


glazing 5 mm

E 85 technical catalogue
01.2011

9.27

gaskets

code/description

ET130181

package/pcs

colour

200

EPDM gasket for


glazing 5 mm

ET130463

80

EPDM gasket for


glazing 6 mm

ET130457

110

EPDM gasket for


glazing 7 mm

ET130458

100

EPDM gasket for


glazing 8 mm

E 85 technical catalogue
01.2011

9.28

code/description

ET130167

package/pcs

colour

120

EPDM gasket for


glazing 8 mm

ET130479

100

EPDM gasket for


glazing 9 mm

ET130470

100

EPDM gasket for


glazing 10 mm

ET130182

100

EPDM gasket for


glazing 10 mm

E 85 technical catalogue
01.2011

9.29

code/description

ET130480

package/pcs

colour

100

EPDM gasket for


glazing 12 mm

ET130500

140

EPDM gasket for


pressure plate

ET130553

160

one side butyl seal


tape 45 mm

ET130551

160

two side butyl seal


tape 50 mm

E 85 technical catalogue
01.2011

9.30

code/description

package/pcs

ET130126

colour

110

silicone gasket for


pressure plate 85702

ET130705

120

silicone gasket for


structural glazing

ET130180

350

EPDM gasket for


projected window

ET130199

100

EPDM expansion joint gasket

E 85 technical catalogue
01.2011

9.31

code/description

package/pcs

ET130198

colour

200

EPDM gasket for E85152,


E85153, E85154, E85155

ET130461

110

EPDM gasket for projected


window for profile E85410

ET130706

45

EPDM external gasket for


projected faade with cover plate

ET130707

110

EPDM external gasket for projected


faade window structural glazing

E 85 technical catalogue
01.2011

9.32

code/description

package/pcs

ET080183

100 /pcs

colour

polyamide joint

code/description

ET080171

package/m

colour

thermal insulation
PVC spacer 16 mm

ET080174

thermal insulation
PVC spacer 21 mm

E 85 technical catalogue
01.2011

9.33

thermal insulation spacers

code/description

package/pcs

ET080172

colour

thermal insulation
PVC spacer 25 mm

ET080173

additional (optional) thermal


insulation PVC spacer

ET080177

thermal insulation spacer


PVC 20x24 mm

20
24

ET080184

26

thermal insulation
spacer PVC 26x28 mm
28

E 85 technical catalogue
01.2011

9.34

code/description

package/pcs

ET162 058

colour

jig for opening the fixing holes


on mullion for the spring operated
fixing part ET 071113.00 between
transom-mullion

ET990 520

jig for cutting the gasket


ET 130500.00, placed
on the pressure plate for
the horizontal members

ET990 523

jig for removing decorative caps

E 85 technical catalogue
01.2011

9.35

tools

code/description

GI2236

package/pcs

10

colour

MF

connection block for handle


for projected window NOVA GI255601
for sash 85 210; 85 211

GI04041

20

antibreack dispositive

GI4020

10

additional locking for projected


window E85 and E8000

BE400R

10

MF

pair of arms for projected window


80 kg for 85

E 85 technical catalogue
01.2011

9.36

projected window

code/description

package/pcs

BE600R

10

colour

MF

pair of arms for projected window


130 kg for 85

BE900R

10

MF

pair of arms for parallel opening


for projected window 120 kg
for 85

BE700R

100

MF

100

MF

spacers for arms


400R and 600R for E85

BE800R

set of nuts for


400R and 600R

E 85 technical catalogue
01.2011

9.37

scheme

FIG 1

E 85 technical catalogue
01.2011

9.38

scheme

number

model

BE400R

adjustable

length L

pening angle

405 mm

25

500 to 1200
mm

665 mm

15

1500 to 2000
mm

80 kg
BE600R

adjustable

130 kg

BE800R
installation on friction
arms with nuts

E 85 technical catalogue
01.2011

height
of sash

9.39

weight, kg

scheme

BE900R

width, mm

E 85 technical catalogue
01.2011

height, mm

weight, kg

number of scissors

1200

1000

60

2000

1500

100

1500

2000

120

9.40

CE MARKING
ALUMINIUM AS MATERIAL

STANDARDS

REQUIREMENTS

E85

curtain wall system

Aluminium as material
Aluminium is a very young metal, extracted for the first time in 1854. Commercially produced as a precious
metal from 1886, its industrial production for civil applications only achieved wide use in the 1950s.
Now aluminium plays a key role for the sustainability of new buildings and the renovation of existing ones.
Thanks to its performance properties aluminium contributes to the energy performance, safety and comfort of
new buildings.

Alloys

Finishing

Aluminium in its pure form is a very soft metal.


Thanks to the addition of alloying elements such as
copper, manganese, magnesium, zinc, etc. and thanks
to suitable production processes, the physical and
mechanical properties can be varied in a wide range
to satisfy the requirements of a large number of
different applications.

Powder coating it is a type of paint that is applied as a dry powder. Coating is applied on ETEM
profiles electrostatically and then is cured under
heat
to allow it to flow and form a skin.
ETEM is authorized to use the quality sign QUALICOAT
for powder coatings on aluminium for architectural
applications. A wide range of colors and gloss levels
can be achieved.

ETEM profiles are extruded from the following alloys:


EN
EN
EN
EN
EN
EN

AW-1050 [ Al 99.5 ]
AW-6060 [ Al Mg Si ]
AW-6063 [Al Mg0,7 Si]
AW-6061 [Al Mg1 Si Cu]
AW-6005 [Al Si Mg]
AW-6082 [Al Si1 Mg Mn]

ETEM also offers timber imitations painting, in addition to all RAL colors. The technology EZY provides
the following colors: Golden Oak, Acero, Betulla,
Mogano, Verde Scuro, Wenge, Noce Fiammato, Noce
Chiaro, Ciliegio Rosso, Acacia Scuro, Ciliegio Antico,
Noce Reale, Ciliegio Reale.

Extrusion process

Anodizing it is an electrochemical process whereby to reinforce the natural oxide film on the aluminium surface, increasing hardness, corrosion and
abrasion resistance. Anodizing gives a very decorative silver matt surface finish, and colored can also
be obtained by
sealing metallic dyes into the anodized layer.

ETEM profiles are obtained through extrusion process, which consists of pushing a hot cylindrical bullet of aluminium through a shaped die. The extrusion
process offers almost infinite range of forms and
sections,
allowing our designers to integrate numerous functions into one single profile.

Maintenance
Apart from routine cleaning for aesthetic reasons,
ETEM aluminium profiles do not require any maintenance which translates into a major cost and ecological advantage over lifetime of the product.

E 85 technical catalogue
01.2011

10.1

E85

curtain wall system

Standards
General

Curtain walling

EN 12020 (12) - Aluminium and aluminium alloys Extruded precision profiles in alloys EN AW-6060
and
EN AW-6063
EN 755 (19) Aluminium and aluminium alloys - Extruded rod/bar, tube and profiles
EN 573 (14) - Aluminium and aluminium alloys Chemical composition and form of wrought products
EN 15088 Aluminium and aluminium alloys Structural products for construction works Technical
conditions for inspection and delivery
EN 1990 Eurocode - Basis of structural design
EN 1991 Eurocode 1 - Actions on structures
EN 1998 Eurocode 8 - Design of structures for
earthquake resistance
EN 1999 Eurocode 9 - Design of aluminium structures

1/ EN 13830 - Curtain walling - Product standard


2/ EN 13119 - Curtain walling Terminology
3/ CWCT Standard for Systemized Building Envelopes
4/ EN 12152 - Curtain walling - Air permeability Performance requirements and classification
5/ EN 12153 - Curtain walling - Air permeability Test method
6/ EN 1026 - Windows and doors - Air permeability
- Test method
7/ EN 12154 -Curtain walling - Watertightness Performance requirements and classification
8/ EN 12155 - Curtain walling - Watertightness Laboratory test under static pressure
9/ ENV 13050 - Curtain walling - Watertightness Laboratory test under dynamic condition of air pressure and water spray
10/ EN 1027 - Windows and doors - Watertightness
- Test method
11/ EN 13116 - Curtain walling - Resistance to wind
load - Performance requirements
12/ EN 12179 - Curtain walling - Resistance to wind
load - Test method
13/ EN 14019 - Curtain Walling - Impact resistance Performance requirements
14/ EN ISO 10077 (12) - Thermal performance of
windows, doors and shutters - Calculation of thermal transmittance
15/ EN 12412-2 - Thermal performance of windows,
doors and shutters - Determination of thermal
transmittance by hot box method - Part 2: Frames
16/ ISO 140 (part 1 and 3) - Acoustics - Measurement of sound insulation in buildings and of building
elements
17/ EN 20140 - Acoustics - Measurement of sound
insulation in buildings and of building elements
18/ EN ISO 717-1 - Acoustics - Rating of sound insulation in buildings and of building elements - Part
1: Airborne sound insulation (ISO 717-1:1996)

E 85 technical catalogue
01.2011

10.2

E85

curtain wall system

Curtain wall
. Definition
4. Air permeability

Curtain walling is a form of predominantly vertical


building envelope which supports no load other than
its own weight and the environmental forces which
act upon it.

An air permeability test shall be carried out in accordance with the corresponding European standard.

5. Watertightness

In this context non-loadbearing means that, unlike a


conventional brick or masonry wall, a curtain wall is
not intended to assist in maintaining the structural
integrity of the building. Dead and live loads are not
intended to be transmitted to it from the supporting
structure and thus transmitted to the foundations.

A watertightness test shall be carried out in accordance with the corresponding European standard.

. Requirements

Where specifically required, sound insulation index


shall be determined by test.

6. Airborne sound insulation


7. Thermal transmittance

1. Resistance to wind load

Methods of assessment / calculation of thermal


transmittance of curtain walling and appropriate
methods of test are defined in EN 13947.

The curtain walling shall be sufficiently rigid to resist the declared wind loads for serviceability, both
positive and negative. It shall transfer the declared
wind loads to the buildings structure, safely, via
the fixings for that purpose.

8. Fire resistance
Where specifically required the fire resistance shall
be classified in accordance with the corresponding
European standard.

2. Dead load (Self-weight)


The curtain wall shall sustain its self-weight plus
any attachments incorporated into it by original
design. It shall transfer the weight to the building
structure, safely, via the fixings intended for that
purpose.

Where specifically required the reaction to fire shall


be classified in accordance with the corresponding
European standard.

Self-weights shall be determined in accordance with


EN 1991-1-1 ( Eurocode 1).

10. Fire propagation

9. Reaction to fire

Where specifically required the curtain wall shall


incorporate such fire and smoke stops as are necessary to prevent the transmission of fire or smoke
through voids in the curtain wall construction at its
abutment at all levels with structural floor slabs.

3. Resistance against impact


Where specifically required tests shall be performed
in accordance with the corresponding European
standard.

E 85 technical catalogue
01.2011

10.3

E85

curtain wall system

11. Durability

15. Thermal shock resistance

Durability of performance of any characteristics


of curtain walling is not tested, but is related to
the results of the conformance of the constituting
materials and finishes to the state of the art, or,
where available to European technical specifications
specifying the material or finish.

Where it is determined that a glass resistant to


thermal shock is required, a suitable strengthened
or toughened glass shall be chosen which conforms
to the appropriate European Standard(s).

16. Building and thermal


movement

12. Water vapour permeability

The design of curtain wall shall accommodate thermal and specified building movements without inducing damage to the components or performance. The
faade engineer shall specify the building movements
which the curtain wall will be required to accommodate, including movements at joints within the
structure.

Vapour control layers which conform to the appropriate European Standard shall take into account
the specified hydro-thermal conditions of the
building.

13. Equipotentiality
Where specifically required the metal component
parts of the curtain wall shall be mechanically
connected together with the building structure to
provide an equipotential bond to the earth circuit
of the building. This is a requirement for all metal
based curtain walling installed into buildings with a
height greater than 25 m. The electrical resistance
of the bond of the curtain wall shall not exceed 10
when tested in accordance with EN 13830,
Annex A.

17. Resistance to live


horizontal loads
The curtain wall shall resist a horizontal live load
at sill height as specified in EN 1999-1-1 (Eurocode
1).

14. Seismic shock resistance


Where specifically required, seismic shock resistance
shall be determined in accordance with technical
specifications or other provisions valid in the place
of use.

NOTE:
The beforementioned definition of curtain wall is extract from CWCT Standard for systemized building envelopes.
The listed requirements for curtain walls are in accordance with harmonized European standard EN 13830.

E 85 technical catalogue
01.2011

10.4

E85

curtain wall system

CE marking
What does the sign CE mean?

- CE ensures free movement of goods within the EU


and the European Free Trade Association (EFTA);

It is an abbreviation of the French Conformite


Europeene- i.e. European Conformity. By placing
the CE marking the manufacturer declares that the
product complies with general safety requirements
set out in CE marking directives.

- CE permits the withdrawal of products that do


not meet
the standards by monitoring and custom authorities;
- Marking with the CE mark is necessary in cases
where the product is distributed within the internal
market.

What is the purpose of CE


marking?

What are the requirements


for the CE marking?

The CE mark represents the European passport of


the product, its main objectives are:

Curtain walls, not concerned with uses subject to


regulations on reaction to fire, are covered by Attestation of conformity system 3 (AoC System 3).
This system sets the following duties:

- CE is a declaration by the manufacturer that the


product meets the essential requirements of relevant European legislation relating to health, safety
and environmental protection;
- CE indicates to officials in relevant ministries and
departments that the product can be put on the
market lawfully in the country;

Tasks to be performed by the manufacturer

Tasks to be performed by
Notified Body

Conformity accessment (the basis for CE marking,


which is set by the final producer)

Factory production
control - FPC

Initial Type Testing


- ITT

EC declaration of conformity issued by the manufacturer or his authorized representative based


on the protocol / s from the initial type testing of
the product - ITT

E 85 technical catalogue
01.2011

10.5

E85

curtain wall system

Methods for obtaining the results from initial type testing of a


product ITT
According to European legislation, the opportunities for the acquisition of ITT results are three1:
Manufacturers ITT

The manufacturer selects a


sample for testing

Shared ITT

Cascading ITT

Partner (e.g. second Manufacturer), industry (e.g. hardware producers) or designer, selects a
sample for testing and imposes
a system of production control

The system supplier selects


samples for testing and imposes a system of production
control

Notified Body tests the


sample

Notified Body tests the sample


Notified Body tests the sample

The manufacturer owns the


ITT test report

The system supplier owns the


ITT test report
The partner owns the ITT test
report

The manufacturer is allowed


to use the ITT of the system
supplier

The manufacturer is allowed to


use the ITT of his partner.

The Notified Body checks that


the product is identical

The manufacturer owns the ITT


test report

-Agreement between the manufacturer and the system supplier


-Instructions for assembling
and installation of the system
supplier relevant for FPC of the
manufacturer
-No reduction of performance
level of product
-System supplier audits activities
of the manufacturer

ITT of the system supplier as


verification for the manufacturer
1

Euro Windoor Guidance sheet, CE marking of windows and pedestrian doors, EuroWindoor, Frankfurt 2007

E 85 technical catalogue
01.2011

10.6

E85

curtain wall system

What is the cascading initial type testing of the product?


-The manufacturer undertakes to comply unconditionally with all instructions of the system supplier
for the product assembly and the method of assembly should be identical to the method of assembling of the sample tested by the system supplier.
The finished product must have the same technical
characteristics as the test sample, otherwise the
manufacturer must test his own product;

The procedure for cascading ITT that ETEM Building


Systems as a system supplier offers to the manufacturers is as follows:
-The system supplier conducts an initial
inspection of FPC of the manufacturer and all accompanying documents;
-Based on the inspection carried out a contract is
concluded with the system supplier;

-The system supplier conducts periodic audits of the


manufacturer, provides technical assistance and
training of the staff of the manufacturer, ongoing
consultations and information.

-Ratification of the contract permits the manufacturer to use the results from the ITT of the
system supplier; Based on the factory production
control system and results from the ITT, the manufacturer can certify that the product complies with
current regulations and may affix CE marking;

Legal acts
- 89/106/EEC Construction Products Directive;
- Product standard for curtain walling EN
13830:2004.

E 85 technical catalogue
01.2011

10.7

E85

curtain wall system

Hatches
for different materials
Hatches for different materials
EPDM

butyl seal

PVC

membrane

silicone seal
gypsum board

backer rod

PVC spacer

silicone seal

E 85 technical catalogue
01.2011

Insulation soft 20 mm

etalbond

Insulation hard 20 mm

sheet aluminium

concrete wall

glass

plaster

aluminium profile

wood

steel

10.8

E85

curtain wall system

Copyright 2010 ETEM


Building Systems
Building Systems is not responsible for any typographical errors, technical inaccuracies and following
changes of the content of this catalogue.

The design, structure and content of this catalogue


are subject of copyright and the exclusive rights
belong to ETEM Building Systems. Modifying, copying,
publishing, selling or licensing any part or the whole
content of this catalogue are strongly prohibited
without the permission of ETEM Building Systems.
Any unauthorized use of content may violate copyright or other laws.

E 85 technical catalogue
01.2011

10.9

Das könnte Ihnen auch gefallen