Beruflich Dokumente
Kultur Dokumente
com
Experience In Motion
owserve.com
Contents
BK 27
63
DK 36/A7
65
DK 47
67
DKT 47
69
Steam Traps MK
DK 57
71
Operation
Tandem seat
73
73
MK 20
11
75
MK 21
13
UNA 26H
77
MK 35/A7
15
UNA 27h
79
MK 35/31
17
81
MK 35/32
19
UNA 50
83
21
UNA 40L
85
MK 45/1
23
UNA 40
87
MK 45/2
25
UNA 60
89
MKT 45
27
UNA 60L
91
MK 35/2S
29
UNA 60MAX
93
MK 35/2S3
31
95
MK 25/2
33
97
MK 25/2S
35
UNA Special PN 25
99
TK 23 and TK 24 (2")
37
UNA 175
101
39
103
41
105
41
UNA 203
107
BK 35/A7
43
UNA 305
109
BK 45
45
BKT 45
47
113
BK 46
49
UNA 14p
115
BK 28
51
UNA 26h
117
BK 29
53
UNA 27h
119
BK 212
55
UNA 39
121
BK 212HT
57
123
BK 212EX
59
125
BK 15
61
127
Steam Traps BK
Operation
111
Contents continued
UNA Special PN 63
129
131
133
AK 45
135
SMK 22
137
GK 11/21
139
UBK 46
141
Check Valves
MB 26a
145
RK 70 and RK 71
147
RK 41
149
RK 44 and RK 44s
151
RK 16
153
RK 86 and RK 86A
155
RK 76
157
RK 49
159
CB 14
161
163
167
FPS-14
169
FPS-23
171
FPS-33L
173
Skid Packages
175
FMAVC
177
FMAVS
179
FMAHC
181
FMAHS
183
165
FPS-11
143
185
187
189
owserve.com
Unaffected by dirt.
UNA
The UNA is a float trap.
Not all steam trap types are equally suitable for a given
application. Depending on the operating conditions and
service in question, one or more systems will be particularly well suited.
Criteria
1. Operation with
different condensates
2. Different modes of
operation
Please note:
Condensate from steam
3*
3**
3*
1
1
3. Operation with
back pressure
1
3
1
1
1
1
4. Sensitivity to dirt
5. Air-venting
Automatic
3*
* Manual air-venting
6. Condensate
discharge at definite temperatures
2*
1*
1**
3*
1*
3*
1
1
1
1
1
1
1
1
1
1
1
1
9. Resistance to waterhammer
1*
1*
7. Frost resistance
8. Condensate
discharge without
loss of live steam
Ratings:
1 = Excellent
2 = Good
3 = Fair or Conditional
= Not recommended
owserve.com
owserve.com
Steam Traps MK
Operation
rises; the membrane with the valve disc is moved in the
closing direction. Just before the condensate has reached
its saturation temperature, the trap is closed completely.
Membrane regulator
Opening The capsule of the membrane regulator is filled
with a liquid having an evaporation temperature that is
just a few degrees below the saturation temperature of
water. During shut-down or start-up of the plant (i.e., if
cold condensate is present), the liquid filling is completely
condensed. The pressure in the capsule is lower than the
surrounding pressure (service pressure); the membrane
with the valve disc is pushed in the opening direction.
Closing With rising condensate temperature, the liquid
filling starts to evaporate. The pressure in the capsule
Tandem seat
The self-centering valve cone n
ensures steam-tight closure. With
rising temperatures the additional
flat seat o closes too and provides
a further guarantee of tightness,
even in the presence of dirt particles.
Moreover, the pressure drop in two
stages across the orifice area of the
trap reduces wear and enhances the
life of the trap.
Trap closed
Both seats are tightly shut off.
o
c
o
c
Rhombus-shaped cover
secured with only two
bolts, which are easy to
insert and easy to use in
restricted spaces.
Thermostatic capsule
Regulator unit replaceable
without removing body from
pipeline. Precise reaction to
any change in temperature.
Corrugated membrane of
Hastelloy . High elasticity,
long service life.
Tandem seat
Double sealing.
Large-surface strainer
Non-return valve
with hollow cone and
reduced mass
Quick closing in the
event of waterhammer.
10
owserve.com
MK 20
Available Sizes: " and "
(DN 15 and 20)
Application
The MK 20 series is designed for low capacity heating
systems. Especially suited for HVAC applications. The
MK 20 series of traps are designed to operate with system
pressures from 25" vacuum to 25 psi, and automatically
vent air and other non-condensable gases.
Features and Benefits
Threaded cover provides for in-line inspection and
maintenance.
25
psi
Maximum p
(1.7 bar)
"'
Materials
Body and Cover Cast Brass
Internals Brass and Stainless Steel
Capacity Chart
The chart shows the maximum capacities of hot water
based on the orifice of the steam traps. The capacities are
a function of differential pressure or the difference between
inlet and outlet pressures for the trap. The cold water
capacity is between 1.1 and 1.7 times the hot capacity,
depending on the differential pressure.
CBS
$BQBDJUZ
%JNFOTJPOTBOE8FJHIUT
/ PNJOBM4J[FT
%JNFOTJPOT
-
)
%
"'
"QQSPY8FJHIU
<JODI>
<NN>
<JODI>
<NN>
<JODI>
<NN>
<JODI>
<NN>
<JODI>
<NN>
<MCT>
<LH>
&OE$POOFDUJPOT
/ 15
11
12
owserve.com
MK 21
Maximum p
(1.7 bar)
25
psi
"'
&
Capacity Chart
The chart shows the maximum capacities of hot water
based on the orifice of the steam traps. The capacities are
a function of differential pressure or the difference between
inlet and outlet pressures for the trap. The cold water
capacity is between 1.1 and 1.7 times the hot capacity,
depending on the differential pressure.
Figures in bold represent inches and lb/h.
Differential Pressure
psi
bar
1/2
0.03
0.07
1 1/2
0.1
1/2
15
120
55
165
75
200
91
Capacity
3/4
20
232
105
325
148
400
182
1
25
409
186
570
259
700
318
D
L
E
AF
Approx. Weight
[inch]
[mm]
[inch]
[mm]
[inch]
[mm]
[inch]
[mm]
[inch]
[mm]
[lbs]
[kg]
End Connections
1/2
15
2.4
62
3.1
78
1.1
28
1.75
45
1.25
0.6
NPT
3/4
20
3.1
78
3.2
81
1.1
28
1.75
45
1.88
0.9
1
25
3.1
78
3.4
87
1.1
28
1.75
48
2
1
13
14
owserve.com
MK 35/A7
Maximum p
(22 bar)
Application
The ECONOline MK 35/A7 steam trap is used for low
capacity applications such as drip and tracing. The trap
is attached to the universal connector by means of 2 hex
head bolts and can be used on any existing connectors in
your piping system.
320
psi
ECONOline
%JNFOTJPOTBOE
8FJHIUT
/ PNJOBM4J[FT
%JNFOTJPOT
"QQSPY 8FJHIU
XPDPOOFDUPS
"QQSPY 8FJHIU
XJUIDPOOFDUPS
<JODI>
<NN>
%<JODI>
<NN>
-<JODI>
<NN>
-<JODI>
<NN>
)<JODI>
<NN>
<MCT>
<LH>
<MCT>
<LH>
&OE$POOFDUJPOT
4DSFXFE4PDLFU8FME
15
320
psi
Maximum p
(22 bar)
MK 35/A7
[lb/h]
2000
[kg/h]
1000
800
1000
800
600
600
500
400
300
500
400
200
300
200
100
Capacity
80
100
60
50
1
2
20
8 10
30 40 50 60 80100
22
200
[bar ]
320 [psi]
PMX
Pressure/Temperature Ratings
Maximum Service Pressure
Related Temperature
Maximum Differential Pressure
[psig]
[barg]
[o F]
[o C]
719
49.6
68
20
613
519
42.3
35.8
212
392
100
200
320 psig (22 barg)
458
31.6
572
300
421
29
842
450
How to Order
For the trap only:
MK 35/A7
For the trap and connector:
Specify trap, end connection size and type.
2.9"
75 mm
16
owserve.com
MK 35/31
305
psi
Maximum p
(21 bar)
Application
The MK 35/31 steam trap is used for lower-capacity applications such as drips, tracers and light process where only
saturated steam is used. The trap features a replaceable
capsule with tandem seated design.
Features and Benefits
Control capsule of Hastelloy and Stainless Steel for
superior corrosion resistance.
Tandem seated control capsule combined with a venturi
style orifice uses a unique double valve and seat for tight
shutoff, cyclical discharge and superior dirt-handling
ability.
Forged Steel Body and Cover.
Standard (N) capsule discharges hot condensate at
approximately 18F (10C) below saturation temperature
throughout its operating range. One internal regulator for
all pressure ranges.
[psig]
[barg]
Related Temperature
Maximum Differential Pressure
305
189
21
13
752
[oF] 437
400
[oC] 225
305 psi (21 bar)
131
9
842
450
Dimensions and
Weights
Nominal Sizes
Dimensions
Approx. Weight
[inch]
[mm]
L [inch]
[mm]
[lbs]
[kg]
End Connections
Screwed / Socketweld
3/8
10
3.7
95
1.5
0.7
1/2
15
3.7
95
1.8
0.8
17
305
psi
Maximum p
(21 bar)
MK 35/31
[lb/h]
2000
[kg/h]
1000
800
600
1000
800
600
400
300
500
400
200
300
200
100
80
60
100
80
Capacity
60
40
30
50
40
20
0.1
2
$PMX
6 8 10
20
30 40
8 10
60 80 100
21
200 305
BC
18
Descri ption
MK 35/31
2a
Capsule (5N1)
376165
2b
Capsule (5U1)
376166
Cover Gasket
0 8 70 80
Strainer
0 8 74 01
Retaini ng Spri ng
0 9 83 17
[bar]
[psi]
owserve.com
MK 35/32
305
psi
Maximum p
(21 bar)
Application
The MK 35/32 steam traps is used for higher-capacity
applications such as drips, tracers and light process where
only saturated steam is used. The trap features a replaceable capsule with single seated design.
Features and Benefits
Control capsule of Hastelloy and Stainless Steel for
superior corrosion resistance.
[psig]
[barg]
305
189
21
13
752
[oF] 437
400
[oC] 225
305 psi (21 bar)
131
9
842
450
Dimensions and
Weights
Nominal Sizes
Dimensions
Approx. Weight
[inch]
[mm]
L [inch]
[mm]
[lbs]
[kg]
End Connections
Screwed / Socketweld
3/8
10
3.7
95
1.5
0.7
1/2
15
3.7
95
1.8
0.8
19
305
psi
Maximum p
(21 bar)
MK 35/32
[Lb/h]
[kg/h]
7000
3000
6000
5000
4000
2000
3000
2000
1000
800
600
1000
800
600
400
300
500
400
200
300
200
100
80
60
100
40
80
30
Capacity
60
50
20
0.1
40
2
$PMX
6 8 10
20
30 40
8 10
60 80 100
21
200 305
[bar]
[psi]
20
Descripti on
MK 35/32
2a
Capsule (5N2)
376175
2b
Capsule (5U2)
376168
Cover Gasket
0 8 70 80
Strainer
0 8 74 01
Retai ni ng Spri ng
0 9 83 17
owserve.com
Application
The MK 36/51 series steam trap is used for low capacity
applications such as drips and tracers where only saturated
steam is used.
MK 36/51
465
psi
Maximum p
(32 bar)
Trap Types
MK 36/51: Body is threaded for capsule replacement and
strainer cleaning.
MK 36/51G: Non-repairable welded body.
Features and Benefits
Control capsule of Hastelloy and Stainless Steel
construction for corrosion resistance.
Tandem seated design and venturi style orifice provides
tight shutoff, cyclical discharge and superior dirt-handling
ability.
Small trap body and low weight excellent for end of line
tracer applications.
Stainless steel construction for superior corrosion
resistance.
MK 36/51G
End Connections
Dimensions and
Weights
Materials
Body ASTM A182 F304 (DIN 1.4301)
Nominal Sizes
Dimensions
Approx. Weight
[inch]
[mm]
A.F. [inch]
[mm]
[lbs]
[kg]
Screwed
1/4
8
1.1
27
1
0.4
3/8
10
1.1
27
1
0.4
1/2
15
1.1
27
1
0.4
3/4
20
1.4
36
1
0.4
21
465
psi
Maximum p
(32 bar)
[lb/h]
2000
[kg/h]
2
1000
800
600
1
1000
400
800
300
600
500
200
400
300
100
200
80
60
100
40
80
30
Capacity
60
50
20
0,1
40
2
$PMX
6 8 10
20
30 40
8 10
60 80 100
22
200
32
465
[bar]
[psi]
[psig]
[barg]
464
189
131
32
13
9
752
842
[oF] 464
400
450
[oC] 240
465 psig (32 barg)
Energy Savings
Flowserve Gestra MK 36/51 (G) steam traps are available
with optional undercooling (U) capsules for open discharge
applications where sensible heat savings and flash steam
suppression are desirable. This capsule discharges
condensate at 54F (30C) below saturation temperature.
Please contact your local Flowserve Gestra representative
for details.
Pressure/Temperature Chart
The chart shows the maximum shell (body) pressure
and temperature rating. Operating differential pressure is
limited to 465 psi.
Material/Test Certificates
Test certificates can be issued on request in accordance
with EN 10204 2.2 and -3.1B. Test and/or Inspection
certificates must be requested at time of order and cannot
be issued after the equipment has been shipped from the
factory.
Available End Connections
Screwed sockets: NPT or BSP
How to Order
Specify trap, end connection size and type.
Item
Number
1
D escription
MK 36/51
Tandem (5N1)
Undercooli ng Tandem (5U1)
376165
376166
B ody
Capsule
22
Strainer
0 8 85 0 3
owserve.com
L
3.8
Tandem Seated
Capsule
1.2
b
l
H2
g
H1
1.2
[psig]
[barg]
464
319
32
22
725
[oF] 482
385
[oC] 250
320 psig (22 barg)
Related Temperature
.OMINAL 3IZES
$IMENSIONS
!PPROX 7EIGHT
[inch]
[mm]
b [inch]
[mm]
k [inch]
[mm]
g [inch]
[mm]
l [inch]
[mm]
Number of bolts
&LANGED
;INCH=
;MM=
, ;INCH=
;MM=
( ;INCH=
;MM=
( ;INCH=
;MM=
;LBS=
;KG=
Flange
Dimensions
305
21
752
400
%ND #ONNECTIONS
$IMENSIONS AND
7EIGHTS
D
k
320
psi
Maximum p
(22 bar)
Application
The RHOMBUSline MK 45/1 steam trap is used for
low capacity applications such as drip and tracing, and
economically combines steam trap, check valve and
Y-Strainer (with optional blow off valve) in a small profile
with a convenient 2-bolt cover for easy maintenance.
Features and Benefits
Forged carbon steel body.
MK 45/1
3CREWED
3OCKET
7ELD
"UTT
7ELD
End Connections
3.7
95
0.6
16
2.6
65
1.8
45
0.6
14
4
DIN
4.1
105
0.7
18
3
75
2.3
58
0.6
14
4
CL 150
4.5
115
0.7
18
3.3
85
2.7
68
0.6
14
4
3.5
88.9
0.4
11.1
2.4
60.3
1.4
34.9
0.6
15.9
4
3.9
98.4
0.5
12.7
2.7
69.8
1.7
42.9
0.6
15.9
4
CL 300
4.2
107.9
0.6
14.3
3.1
79.4
2
50.8
0.6
15.9
4
3.7
95.2
0.6
14.3
2.6
66.7
1.4
34.9
0.6
15.9
4
4.6
117.5
0.6
15.9
3.2
82.5
1.7
42.9
0.7
19
4
4.9
123.8
0.7
17.5
3.5
88.9
2
50.8
0.7
19
4
23
320
psi
Maximum p
(22 bar)
[lb/h]
2000
[kg/h]
1000
800
600
1000
800
600
400
300
500
400
200
300
200
MK 45/1
100
80
60
100
80
Capacity
60
40
30
50
40
20
0.1
2
$PMX
6 8 10
'
20
30 40
8 10
60 80 100
22
200 320
&
[bar]
[psi]
Material/Test Certificates
All inspection requirements must be stated at time of order.
Test certificates can be issued on request at extra cost in
accordance with EN 10204 2.2 and -3.1B. Heat Codes on
Body and Cover are required.
E,F,H
24
D escripti on
Complete Membrane
regulator including
cover gasket
MK 45-1
5N1
5U1
3 7 51 09
375111
J, K , L
Thermostati c capsule
Cover Gasket
37 5 02 2I
Strainer Gasket
0 13 3 22
375113
5N1
5U1
376165
376166
owserve.com
MK 45/2
Maximum p
(22 bar)
Application
The RHOMBUSline MK 45/2 steam trap is used for
low capacity applications such as drip and tracing, and
economically combines steam trap, check valve and
Y-Strainer (with optional blow off valve) in a small profile
with a convenient 2-bolt cover for easy maintenance.
320
psi
4JOHMF4FBUFE
$BQTVMF
C
)
H
%
L
)
$IMENSIONS
305
21
752
400
%ND #ONNECTIONS
$IMENSIONS AND
7EIGHTS
.OMINAL 3IZES
464
319
32
22
725
[oF] 482
385
[oC] 250
320 psig (22 barg)
Related Temperature
[psig]
[barg]
&LANGED
;INCH=
;MM=
, ;INCH=
;MM=
( ;INCH=
;MM=
( ;INCH=
;MM=
;LBS=
;KG=
3CREWED
3OCKET
7ELD
"UTT
7ELD
Materials
Body and Cover ASTM A105 (DIN 1.0460)
Cover Bolts ASTM A193B7 (DIN 1.7258)
Flange
Dimensions
D
[inch]
[mm]
b [inch]
[mm]
k [inch]
[mm]
g [inch]
[mm]
l [inch]
[mm]
Number of bolts
End Connections
3.7
95
0.6
16
2.6
65
1.8
45
0.6
14
4
DIN
4.1
105
0.7
18
3
75
2.3
58
0.6
14
4
CL 150
4.5
115
0.7
18
3.3
85
2.7
68
0.6
14
4
3.5
88.9
0.4
11.1
2.4
60.3
1.4
34.9
0.6
15.9
4
3.9
98.4
0.5
12.7
2.7
69.8
1.7
42.9
0.6
15.9
4
CL 300
4.2
107.9
0.6
14.3
3.1
79.4
2
50.8
0.6
15.9
4
3.7
95.2
0.6
14.3
2.6
66.7
1.4
34.9
0.6
15.9
4
4.6
117.5
0.6
15.9
3.2
82.5
1.7
42.9
0.7
19
4
4.9
123.8
0.7
17.5
3.5
88.9
2
50.8
0.7
19
4
25
320
psi
Maximum p
(22 bar)
[kg/h]
[lb/h]
7000
6000
3000
5000
2000
MK 45/2
4000
3000
1000
2000
800
600
1000
400
800
300
600
500
200
400
300
100
200
80
60
100
40
80
30
Capacity
60
50
20
0.1
40
2
$PMX
6 8 10
'
20
30 40
8 10
60 80 100
22
200 320
&
[bar]
[psi]
Material/Test Certificates
All inspection requirements must be stated at time of order.
Test certificates can be issued on request at extra cost in
accordance with EN 10204 2.2 and -3.1B. Heat Codes on
Body and Cover are required.
26
D escri pti on
MK 45-2
E,F,H
Complete Membrane
regulator i ncludi ng
cover gasket
J, K , L
Thermostati c capsule
Cover Gasket
37 5 02 2I
0 13 3 22
5N2
5U2
375110
375112
375113
5N2
5U2
376175
376168
owserve.com
Application
The RHOMBUSline MKT 45 steam trap is used for low
capacity applications such as drip and tracing where a
positive indication of operational mode is required. The
temperature probe provides an accurate readout of internal
trap conditions. Performance can be quantified and
displayed in a DCS system.
MKT 45
Maximum p
(22 bar)
M
)
320
psi
%
L
)
.OMINAL 3IZES
$IMENSIONS
;INCH=
;MM=
, ;INCH=
;MM=
( ;INCH=
;MM=
( ;INCH=
;MM=
;LBS=
;KG=
Flange
Dimensions
D
[inch]
[mm]
b [inch]
[mm]
k [inch]
[mm]
g [inch]
[mm]
l [inch]
[mm]
Number of bolts
305
21
752
400
%ND #ONNECTIONS
$IMENSIONS AND
7EIGHTS
464
319
32
22
725
[oF] 482
385
[oC] 250
320 psig (22 barg)
Related Temperature
[psig]
[barg]
&LANGED
3CREWED
3OCKET
7ELD
"UTT
7ELD
End Connections
3.7
95
0.6
16
2.6
65
1.8
45
0.6
14
4
DIN
4.1
105
0.7
18
3
75
2.3
58
0.6
14
4
CL 150
4.5
115
0.7
18
3.3
85
2.7
68
0.6
14
4
3.5
88.9
0.4
11.1
2.4
60.3
1.4
34.9
0.6
15.9
4
3.9
98.4
0.5
12.7
2.7
69.8
1.7
42.9
0.6
15.9
4
CL 300
4.2
107.9
0.6
14.3
3.1
79.4
2
50.8
0.6
15.9
4
3.7
95.2
0.6
14.3
2.6
66.7
1.4
34.9
0.6
15.9
4
4.6
117.5
0.6
15.9
3.2
82.5
1.7
42.9
0.7
19
4
4.9
123.8
0.7
17.5
3.5
88.9
2
50.8
0.7
19
4
27
320
psi
Maximum p
(22 bar)
'
MKT 45
&
Material/Test Certificates
All inspection requirements must be stated at time of order.
Test certificates can be issued on request at extra cost in
accordance with EN 10204 2.2 and -3.1B. Body and Cover
heat codes are required. Range settings and calibration
certificate are supplied with each MKT 45.
%&(
* + ,
$ ESCRI PTI ON
#OMPLETE -EMBRANE
REGULATOR I NCLUDI NG
COVER GASKET
-+
.
5
.
5
.
5
.
5
4HERMOSTATI C CAPSULE
-+
How to Order
Specify end connection size and type.
#OVER 'ASKET
)
)
4EMPERATURE 0ROBE
WITH 0LUG
0
0
28
owserve.com
Application
The MK 35/2S 1" steam trap is used for process service
such as heat exchangers, tank coils, large air heaters, etc.
The membrane thermostatic capsules in the trap operate
independently and will adjust very quickly to changes
in load. These traps are ideally suited for many process
applications.
MK 35/2S
320
psi
Maximum p
(22 bar)
2.4"
Space required
for opening trap
[psig]
[barg]
[oF]
[oC]
Related Temperature
740
51
68
20
$IMENSIONS AND
7EIGHTS
.OMINAL 3IZES
Materials
Body ASTM A105 (DIN 1.0460)
Capsules Hastelloy and Stainless Steel
Other Internals Stainless Steel
!PPROX 7EIGHT
;INCH=
;MM=
, ;INCH=
;MM=
( ;INCH=
;MM=
;LBS=
;KG=
637
564
43.9
38.9
392
572
200
300
320 psig (22 barg)
502
34.6
752
400
416
28.7
797
425
%ND #ONNECTIONS
"UTT
7ELD
3CREWED
3OCKET 7ELD
&LANGED
29
320
psi
Maximum p
(22 bar)
MK 35/2S
[lb/h]
[kg/h]
5000
10000
4000
8000
3000
6000
2000
4000
3000
1000
2000
800
600
1000
400
800
300
600
500
200
400
Capacity
300
100
0.1
200
2
%PMX
4 5 6
8 10
2
20
8 10
30 40 50 60 80 100
22
200
[bar]
320
[psi]
E
F
Material/Test Certificates
Test certificates can be issued on request in accordance
with EN 10204 2.2 and -3.1B. All inspection requirements
must be stated with the order. Heat codes from body and
cover are required.
Available End Connections
NPT, BSP
Flanged: ANSI 150, 300
SW
How to Order
Specify trap, end connection size and type.
For Example: MK 35/2S 1" (H) NPT
30
Description
Regulator with cover gasket
Includes items B, C, D, & F
Capsule 5H2
Cover gasket
Strainer & Cover gasket kit
MK 35/2S
376730
376174
560493
376732
owserve.com
Application
The MK 35/2S3 1" steam trap is used for process service
such as heat exchangers, tank coils, large air heaters, etc.
The membrane thermostatic capsules in the trap operate
independently and will adjust very quickly to changes
in load. These traps are ideally suited for many process
applications.
Features and Benefits
Three (3) modulating control capsules of Hastelloy
and Stainless Steel for superior corrosion resistance
that independently control the flow of condensate in a
modulating fashion for good temperature control and
smooth condensate flow.
MK 35/2S3
320
psi
Maximum p
(22 bar)
[psig]
[barg]
o
Related Temperature
[ F]
[oC]
740
51
68
20
637
564
43.9
38.9
392
572
200
300
320 psig (22 barg)
502
34.6
752
400
416
28.7
797
425
$IMENSIONS AND
7EIGHTS
.OMINAL 3IZES
$IMENSIONS
;INCH=
;MM=
, ;INCH=
;MM=
( ;INCH=
;MM=
;LBS=
;KG=
%ND #ONNECTIONS
"UTT
7ELD
3CREWED
3OCKET 7ELD
&LANGED
31
320
psi
Maximum p
(22 bar)
MK 35/2S3
[lb/h]
[kg/h]
20000
8000
6000
10000
4000
8000
3000
6000
2000
4000
3000
1000
2000
800
600
1000
400
800
300
600
500
200
400
Capacity
300
100
0.1
200
2
%PMX
4 5 6
8 10
2
20
8 10
30 40 50 60 80 100
22
200
320
[bar]
[psi]
32
Description
Regulator with cover gasket
Includes items B, C, D, & F
Capsule 5H2
Cover gasket
Strainer & Cover gasket kit
MK 35/2S3
376731
376174
560493
376732
owserve.com
Application
The MK 25/2 steam trap is used for process service such
as heat exchangers, tank coils, large air heaters, etc.
The membrane thermostatic capsules in the trap operate
independently and will adjust very quickly to changes
in load. These traps are ideally suited for many process
applications.
MK 25/2
[psig]
[barg]
[oF]
[oC]
Related Temperature
740
51
68
20
$IMENSIONS AND
7EIGHTS
.OMINAL 3IZES
$IMENSIONS
Maximum p
(22 bar)
320
psi
!PPROX 7EIGHT
;INCH=
;MM=
, ;INCH=
;MM=
( ;INCH=
;MM=
;LBS=
;KG=
637
564
43.9
38.9
392
572
200
300
320 psig (22 barg)
502
34.6
752
400
293
20.2
842
450
%ND #ONNECTIONS
3CREWED
3OCKET 7ELD
&LANGED
33
320
psi
Maximum p
(22 bar)
MK 25/2
[lb/h]
[kg/h]
33000
15000
10000
20000
8000
6000
10000
8000
6000
4000
4000
3000
2000
3000
2000
1000
800
600
1000
400
Capacity
800
600
500
400
300
200
0.1
2
%PMX
4 5 6
8 10
2
20
8 10
30 40 50 60 80 100
22
200
320
[bar]
[psi]
34
Descri pti on
MK 25/2
Regulati ng Membrane
5H2
5OH2
376174
0 8 51 84
0 9 88 97
C over Gasket
0 8 70 95
Strai ner
0 9 68 91
Nozzle Seat
0 9 70 29
C over Bolts
011254
owserve.com
MK 25/2S
320
psi
Maximum p
(22 bar)
Application
The MK 25/2S steam trap is used for process service such
as heat exchangers, tank coils, large air heaters, etc. The
traps should be sized according to the capacity required by
the application. The membrane thermostatic capsules in
the trap operate independently and will adjust very quickly
to changes in load. These traps are ideally suited for many
process applications.
Features and Benefits
Nine (9) modulating control capsules of Hastelloy and
Stainless Steel for superior corrosion resistance that
independently control the flow of condensate.
Standard (H) capules discharge hot condensate in a
modulating fashion at approximately 9F (5C) below
saturation temperature throughout its operating range.
Resistant to water hammer.
Self-draining will not freeze when installed in gravity
drainage position.
Automatically vents air and non-condensable gases and
has a high (>2:1) cold water capacity for rapid start-up.
Very compact and lightweight design relative to other
comparable steam traps in its capacity range. This saves
time in installation and piping.
Operates with zero steam loss throughout its operating
range saving steam and money during the life of the trap.
Related Temperature
[ F]
[oC]
740
51
68
20
$IMENSIONS AND
7EIGHTS
.OMINAL 3IZES
$IMENSIONS
[psig]
[barg]
!PPROX 7EIGHT
;INCH=
;MM=
, ;INCH=
;MM=
( ;INCH=
;MM=
;LBS=
;KG=
637
564
43.9
38.9
392
572
200
300
320 psig (22 barg)
502
34.6
752
400
293
20.2
842
450
%ND #ONNECTIONS
3CREWED
3OCKET 7ELD
&LANGED
Materials
Body and Cover ASTM A105 (DIN 1.0460)
Capsules Hastelloy and Stainless Steel
Other Internals Stainless Steel
Body Pressure/Temperature Rating
The chart shows the maximum shell (body) pressure
and temperature rating. Operating differential pressure is
limited to 320 psi.
35
320
psi
Maximum p
(22 bar)
MK 25/2S
[lb/h]
[kg/h]
55000
25000
44000
20000
2
15000
10000
20000
8000
6000
10000
4000
8000
3000
6000
2000
4000
3000
1000
2000
800
Capacity
600
1000
400
800
0.1
2
%PMX
4 5 6
8 10
2
20
8 10
30 40 50 60 80 100
% &
) *
22
200
320
[bar]
[psi]
(
'
36
Description
MK 25/2S
Regulating Membrane
5H2
5OH2
376174
0 8 51 84
0 9 76 37
C over Gasket
0 8 70 95
Strai ner
0 9 68 91
Nozzle Seat
0 9 76 33
C over Bolts
011254
owserve.com
TK 23 and TK 24
200
psi
Maximum p
(14 bar)
[psig]
[barg]
[psig]
[barg]
230
16
248
120
Related Temperature
[ F]
[oC]
Maximum Differential
Pressure
$IMENSIONS
!PPROX 7EIGHT
305
21
145
10
572
300
$IMENSIONS AND
7EIGHTS
.OMINAL 3IZES
TK 24
185
13
Maximum Operating
Temperature
Maximum Service Pressure
TK 23
;INCH=
;MM=
, ;INCH=
;MM=
( ;INCH=
;MM=
;LBS=
;KG=
360
25
248
120
185
13
752
400
"ODY 3TY LE
4+
4+
37
200
psi
Maximum p
(14 bar)
TK 23 and TK 24
Class Rating: TK 23 PN 16
TK 24 PN 25
TK 24
[lb/h]
TK 23
[t/h]
100000
40
80000
30
60000
50000
40000
20
30000
The same chart is used for both the TK 23 and the TK 24.
10
Capacity
20000
8
6
10000
8000
[bar]
0.2
0.1
1,5 2
%PMX
0.3 0.4
4
5 6
0.6 0.8 1
8 10
2
20
4 5 6
30 40 50 60 80 100
H
E
200
[psi]
G
I
8 10 14
D
F
Descri pti on
TK 23/24
Regulati ng Membrane
5H2
5OH2
376174
376272
Regulator Gaske t
3 7 02 1 5
C over Gaske t
0 8 75 0 9
Adjustment Assembly
Gasket
0 1 33 27
Plug Gasket
0 0 09 9 2
38
C over Bolts
I
Material/Test Certificates
Test certificates can be issued on request in accordance
with EN 10204 2.2 and -3.1B. All inspection requirements
must be stated with the order. Heat codes from body and
cover are required.
TK 23
TK 24
011519
0 1 00 85
owserve.com
TK 23 and TK 24
200
psi
Maximum p
(14 bar)
Application
The TK 23 and TK 24 steam traps are used for very high
capacity process load applications such as large heat
exchangers, reboilers, digesters and rotating dryers.
Both the TK 23 and the TK 24 are operationally identical;
however, the materials of construction are changed to allow
for higher maximum operating conditions for the TK 24.
TK 23: Cast Iron, 145 psi Maximum p
TK 24: Cast Steel, 200 psi Maximum p
Features and Benefits
Four (4) modulating control capsules of Hastelloy and
Stainless Steel construction for corrosion resistance
control pilot flow. Subsequent equalization of pressures
provide for full stem lift, opening very large orifice.
Standard (H) capules discharge hot condensate in a
modulating fashion at approximately 9F (5C) below
saturation temperature throughout its operating range.
Resistant to water hammer.
Very compact and lightweight design relative to other
comparable steam traps in its capacity range. This saves
time in installation and piping.
Related Temperature
.OMINAL 3IZES
$IMENSIONS
[psig]
[barg]
[oF]
[oC]
Maximum Differential
Pressure
$IMENSIONS AND
7EIGHTS
!PPROX 7EIGHT
;INCH=
;MM=
, ;INCH=
;MM=
( ;INCH=
;MM=
( ;INCH=
;MM=
;LBS=
;KG=
TK 23
TK 24
185
13
305
21
Maximum Operating
Temperature
Maximum Service Pressure
[psig]
[barg]
230
16
248
120
145
10
572
300
360
25
248
120
185
13
752
400
"ODY 3TY LE
4+
4+
4+
4+
4+
4+
39
200
psi
Maximum p
(14 bar)
TK 23 and TK 24
Class Rating: TK 23 PN 16
TK 24 PN 25
TK 24
[lb/h]
TK 23
[t/h]
400
800000
300
600000
500000
400000
200
300000
The same chart is used for both the TK 23 and the TK 24.
100
200000
80
60
100000
DN
100
40
80000
30
60000
50000
40000
6
DN
5, D
0
N8
20
30000
10
Capacity
20000
8
6
10000
8000
[bar]
0.1
1,5 2
%PMX
0.3 0.4
0.2
3
5 6
0.6 0.8 1
8 10
20
4 5 6
8 10 14
30 40 50 60 80 100
200
[psi]
Descri pti on
TK 23 / 24
B od y
Regulating Membrane
5H2
5OH2
376174
376272
Seat Gasket
3 7 02 1 6
C over Gasket
4
2 1/2" to 3"
4"
Adjustment Assembly
Gasket
0 8 75 10
087511
0 0 09 92
C over Bolts
40
TK 23
TK 24
011519
011133
owserve.com
Steam Traps BK
Operation
41
Rhombus-shaped cover
secured with only two
bolts, which are easy to
insert and easy to use in
restricted spaces.
Thermovit regulator
Light and compact
regulator unit, replaceable
without removing body
from pipeline. Withstands
waterhammer and freezing.
Easy maintenance.
Stage nozzle
Thermodynamic control.
Wear resistant. Freely
mounted for non-return
valve action.
42
Large-surface strainer
Metal base bushing
owserve.com
BK 35/A7
Maximum p
(22 bar)
Application
The ECONOline BK 35/A7 steam trap is used for low
capacity applications such as drip and tracing. The trap
is attached to the universal connector by means of 2 hex
head bolts and can be used on any existing connectors in
your piping system.
320
psi
ECONOline
L1
L
%JNFOTJPOTBOE
8FJHIUT
/ PNJOBM4J[FT
%JNFOTJPOT
"QQSPY 8FJHIU
XPDPOOFDUPS
"QQSPY 8FJHIU
XJUIDPOOFDUPS
<JODI>
<NN>
%<JODI>
<NN>
-<JODI>
<NN>
-<JODI>
<NN>
)<JODI>
<NN>
<MCT>
<LH>
<MCT>
<LH>
&OE$POOFDUJPOT
4DSFXFE4PDLFU8FME
43
320
psi
Maximum p
(22 bar)
BK 35/A7
[lb/h]
[kg/h]
2000
4000
3000
1000
2000
800
600
500
1000
400
800
300
600
500
200
400
300
100
200
80
60
50
Capacity
100
40
80
30
60
1
20
DPMX
22 [bar]
8 10
30 40 50 60 80100
200
320 [psi]
Socket-weld
Butt weld
[psig]
[barg]
[oF]
[oC]
719
49.6
68
20
613
519
42.3
35.8
212
392
100
200
320 psig (22 barg)
458
31.6
572
300
421
29
842
450
How to Order
For the trap only:
BK 35/A7
For the trap and connector:
Specify trap, end connection size and type.
2.9"
75 mm
44
owserve.com
Maximum p
(22 bar)
Application
The RHOMBUSline BK 45 steam trap is used for low
capacity applications such as drip and tracing, and
economically combines steam trap, check valve and
Y-Strainer (with optional blow off valve) in a small profile
with a convenient 2-bolt cover for easy maintenance.
320
psi
L
Space required for
opening trap
3.8
2.8
BK 45
b
H2
1.2
[psig]
[barg]
464
319
32
22
725
[ F] 482
o
385
[ C] 250
320 psig (22 barg)
o
Related Temperature
$IMENSIONS
%ND #ONNECTIONS
$IMENSIONS AND
7EIGHTS
.OMINAL 3IZES
!PPROX 7EIGHT
305
21
752
400
&LANGED
;INCH=
;MM=
, ;INCH=
;MM=
( ;INCH=
;MM=
( ;INCH=
;MM=
;LBS=
;KG=
3CREWED
3OCKET
7ELD
"UTT
7ELD
Flange
Dimensions
D
[inch]
[mm]
b [inch]
[mm]
k [inch]
[mm]
g [inch]
[mm]
l [inch]
[mm]
Number of bolts
End Connections
3.7
95
0.6
16
2.6
65
1.8
45
0.6
14
4
DIN
4.1
105
0.7
18
3
75
2.3
58
0.6
14
4
CL 150
4.5
115
0.7
18
3.3
85
2.7
68
0.6
14
4
3.5
88.9
0.4
11.1
2.4
60.3
1.4
34.9
0.6
15.9
4
3.9
98.4
0.5
12.7
2.7
69.8
1.7
42.9
0.6
15.9
4
CL 300
4.2
107.9
0.6
14.3
3.1
79.4
2
50.8
0.6
15.9
4
3.7
95.2
0.6
14.3
2.6
66.7
1.4
34.9
0.6
15.9
4
4.6
117.5
0.6
15.9
3.2
82.5
1.7
42.9
0.7
19
4
4.9
123.8
0.7
17.5
3.5
88.9
2
50.8
0.7
19
4
45
320
psi
Maximum p
(22 bar)
BK 45
Available Sizes: ", " and 1"
(DN 15, 20 and 25)
Capacity Charts
The chart shows the maximum capacities for hot and cold
condensate as a function of differential pressure or the
difference between inlet and outlet pressures for the trap.
Curve 1 shows the maximum capacity when discharging
hot condensate that is 18F (10C) below steam saturation temperature. For example, at a differential pressure
of 100 psi, the maximum hot capacity is approximately
770 lb/hr.
Capacity
%PMX
1SFTTVSF
<CBS> <QTJ>
Material/Test Certificates
All inspection requirements must be stated at time of order.
Test certificates can be issued on request in accordance
with EN 10204 2.2 and -3.1B. Body and Cover heat codes
are required.
S t an d ar d S p a r e P ar t s
Item
Number
46
Descri pti on
B K 45
B K 45 U
D, F
C omplete Regulator
i ncludi ng cover
gasket
3 7 52 34
37 5 23 5
J, K , L
375113
375113
owserve.com
Maximum p
(22 bar)
Application
The RHOMBUSline BKT 45 steam trap is used for low
capacity applications such as drip and tracing where a
positive indication of operational mode is required. The
temperature probe provides an accurate readout of internal
trap conditions. Performance can be quantified and
displayed in a DCS system.
320
psi
L
3.8
2.8
H2
BKT 45
H1
2.6
.OMINAL 3IZES
$IMENSIONS
!PPROX 7EIGHT
Materials
Body and Cover ASTM A105 (DIN 1.0460)
Cover Bolts ASTM A193 B7 (DIN 1.7258)
Bimetallic Regulator Stainless Steels
Other Internals Stainless Steel
Temperature probe stem Stainless Steel
Temperature probe housing Phenolic
%ND #ONNECTIONS
$IMENSIONS AND
7EIGHTS
;INCH=
;MM=
, ;INCH=
;MM=
( ;INCH=
;MM=
( ;INCH=
;MM=
;LBS=
;KG=
Flange
Dimensions
D
[inch]
[mm]
b [inch]
[mm]
k [inch]
[mm]
g [inch]
[mm]
l [inch]
[mm]
Number of bolts
&LANGED
3CREWED
3OCKET
7ELD
"UTT
7ELD
End Connections
3.7
95
0.6
16
2.6
65
1.8
45
0.6
14
4
DIN
4.1
105
0.7
18
3
75
2.3
58
0.6
14
4
CL 150
4.5
115
0.7
18
3.3
85
2.7
68
0.6
14
4
3.5
88.9
0.4
11.1
2.4
60.3
1.4
34.9
0.6
15.9
4
3.9
98.4
0.5
12.7
2.7
69.8
1.7
42.9
0.6
15.9
4
CL 300
4.2
107.9
0.6
14.3
3.1
79.4
2
50.8
0.6
15.9
4
3.7
95.2
0.6
14.3
2.6
66.7
1.4
34.9
0.6
15.9
4
4.6
117.5
0.6
15.9
3.2
82.5
1.7
42.9
0.7
19
4
4.9
123.8
0.7
17.5
3.5
88.9
2
50.8
0.7
19
4
47
320
psi
Maximum p
(22 bar)
BKT 45
1SFTTVSF
<CBS> <QTJ>
[psig]
[barg]
Related Temperature
Maximum Differential Pressure
464
319
32
22
725
[oF] 482
385
[oC] 250
320 psig (22 barg)
305
21
752
400
Material/Test Certificates
All inspection requirements must be stated at time of order.
Test certificates can be issued on request in accordance
with EN 10204 2.2 and -3.1B. Body and Cover heat codes
are required. Range settings and calibration certificate are
supplied with each BKT 45.
Available End Connections
Flanges: ANSI 150RF and 300RF (DIN, PN 40)
Screwed sockets: NPT, BSP
Socket-weld, Butt weld
How to Order
Specify end connection size and type.
S t an d ar d S p a r e P a r t s
Item
Number
48
Descri pti on
B K T 45
B K T 45 U
D, F
C omplete Regulator
includi ng cover
g as k et
3 75 23 4
3 75 2 35
0 13 32 2
0 13 3 22
Temperature Probe
with plug
90 2 00 3P
9 02 00 3 P
owserve.com
Maximum p
(32 bar)
Application
The RHOMBUSline BK 46 steam trap is used for low
capacity applications such as drip and tracing, and
economically combines steam trap, check valve and
Y-Strainer (with optional blow off valve) in a small profile
with a convenient 2-bolt cover for easy maintenance.
465
psi
L
Space required for
opening trap
3.8
2.8
BK 46
b
H2
g
k
Materials
Body and Cover ASTM A182 F12 (DIN 1.5415)
Cover Bolts ASTM A193 B7 (DIN 1.7258)
Bimetallic Regulator Stainless Steels
Other Internals Stainless Steel
[psig]
[barg]
508
464
35
32
635
[oF] 572
335
[oC] 300
465 psig (32 barg)
Related Temperature
Maximum Differential Pressure
.OMINAL 3IZES
$IMENSIONS
!PPROX 7EIGHT
[inch]
[mm]
b [inch]
[mm]
k [inch]
[mm]
g [inch]
[mm]
l [inch]
[mm]
Number of bolts
&LANGED
;INCH=
;MM=
, ;INCH=
;MM=
( ;INCH=
;MM=
( ;INCH=
;MM=
;LBS=
;KG=
Flange
Dimensions
406
28
842
450
%ND #ONNECTIONS
$IMENSIONS AND
7EIGHTS
1.2
H1
3CREWED
3OCKET
7ELD
"UTT
7ELD
End Connections
3.7
95
0.6
16
2.6
65
1.8
45
0.6
14
4
DIN
4.1
105
0.7
18
3
75
2.3
58
0.6
14
4
CL 150
4.5
115
0.7
18
3.3
85
2.7
68
0.6
14
4
3.5
88.9
0.4
11.1
2.4
60.3
1.4
34.9
0.6
15.9
4
3.9
98.4
0.5
12.7
2.7
69.8
1.7
42.9
0.6
15.9
4
CL 300
4.2
107.9
0.6
14.3
3.1
79.4
2
50.8
0.6
15.9
4
3.7
95.2
0.6
14.3
2.6
66.7
1.4
34.9
0.6
15.9
4
4.6
117.5
0.6
15.9
3.2
82.5
1.7
42.9
0.7
19
4
4.9
123.8
0.7
17.5
3.5
88.9
2
50.8
0.7
19
4
49
465
psi
Maximum p
(32 bar)
BK 46
Capacity
DPMX
Pressure
[Bar] [Psi]
41
600
38
550
35
500
31
450
27
400
24
350
475 500
246 260
600
315
650
700
343
371
750
800
399
427
[OC]
Temp.
Material/Test Certificates
All inspection requirements must be stated at time of order.
Test certificates can be issued on request in accordance
with EN 10204 2.2 and -3.1B. Body and Cover heat codes
are required.
Available End Connections
Flanges: ANSI 150RF and 300RF (DIN, PN 40)
Screwed sockets: NPT, BSP
Socket-weld, Butt weld
J K
How to Order
Specify trap, end connection size and type.
3 T AN D AR D 3 P AR E 0 AR T S
)TEM
.UMBER
50
$ESCRI PTI ON
" +
$ &
# OMPLETE 2EGULATOR
INCLUDING COVER GASKET
* + ,
owserve.com
Maximum p
(85 bar)
Application
The BK 28 is designed for high pressure drip applications
including: steam main drip, turbine drain, etc. Excellent for
superheated steam drip applications.
1230
psi
4.33
4.53
BK 28
3.62
1SFTTVSF
<CBS> <QTJ>
<'>5FNQ
<$>5FNQ
[psig]
[barg]
Materials
Body and Cover ASTM-A182 F12
1233
972
85
67
842
[ F] 572
o
450
[ C] 300
1230 psig (85 barg)
o
%ND #ONNECTIONS
$IMENSIONS AND
7EIGHTS
.OMINAL 3IZES
$IMENSIONS
!PPROX 7EIGHT
;INCH=
;MM=
, ;INCH=
;MM=
;LBS=
;KG=
&LANGED
3CREWED
3OCKET
7ELD
"UTT
7ELD
51
1230
psi
Maximum p
(85 bar)
BK 28
;KGH=
;LBH=
#APACITY
Capacity Charts
The chart shows the maximum capacities for hot and cold
condensate. The capacities are a function of differential
pressure or the difference between inlet and outlet pressures for the trap.
%0-8
;BAR=
'
&
Material/Test Certificates
All inspection requirements must be stated at time of order.
Test certificates can be issued upon request in accordance
with EN 10204 2.2 and -3.1B. Heat codes from Body and
Cover are required.
Available End Connections
NPT, BSP
Flanges: ANSI 600 (DIN PN 40)
52
B K 28
Regulator
3 7 02 81
Cover Gasket
0 8 65 19
Strainer
0 9 67 01
Cover Bolts
013644
013574
How to Order
Specify trap, end connection size and type.
For Example: BK 28 " SW
owserve.com
Maximum p
(110 bar)
Application
The BK 29 is designed for high pressure drip applications
including steam main drip, turbine protection drain, etc.
Excellent for superheated steam drip applications.
1600
psi
4.33
4.53
BK 29
3.62
L
1SFTTVSF
<CBS> <QTJ>
<'>5FNQ
<$>5FNQ
[psig]
[barg]
Related Temperature
1595
667
110
46
1004
[ F] 752
o
540
[ C] 400
1595 psig (110 barg)
o
%ND #ONNECTIONS
$IMENSIONS AND
7EIGHTS
.OMINAL 3IZES
$IMENSIONS
!PPROX 7EIGHT
;INCH=
;MM=
, ;INCH=
;MM=
;LBS=
;KG=
&LANGED
3CREWED
3OCKET
7ELD
"UTT
7ELD
53
1600
psi
Maximum p
(110 bar)
BK 29
;LBH=
;KGH=
#APACITY
Capacity Charts
The charts show the maximum capacities for hot and cold
condensate. The capacities are a function of differential
pressure or the difference between inlet and outlet pressures for the trap.
%0-8
;BAR=
'
&
Material/Test Certificates
Test certificates can be issued on request in accordance
with EN 10204 2.2 and -3.1B. Heat Codes from Body and
Cover are required.
Available End Connections
Flanges: ANSI 900/1500 (DIN PN)
Socket-weld, Butt weld
How to Order
Specify trap, end connection size and type.
54
Descri pti on
BK 29
Regulator
3 7 02 81
Cover Gasket
372095
Strainer
0 9 67 01
Cover Bolts
014231
010746
owserve.com
Application
The BK 212 is designed for high pressure drip applications
including: steam main drip, turbine protection drain, etc.
Excellent for superheated steam drip applications.
Features and Benefits
Forged alloy steel body with Titanium body shield to resist
flashing damage.
3625
psi
Maximum p
(250 bar)
BK 212
1SFTTVSF
<CBS> <QTJ>
[psig]
[barg]
3814 2639
263
182
977
[ F] 887
o
525
[ C] 475
3625 psig (250 barg)
o
Related Temperature
%ND #ONNECTIONS
$IMENSIONS AND
7EIGHTS
.OMINAL 3IZES
$IMENSIONS
!PPROX 7EIGHT
;INCH=
;MM=
, ;INCH=
;MM=
;LBS=
;KG=
&LANGED
3CREWED
3OCKET
7ELD
"UTT
7ELD
55
3625
psi
Maximum p
(250 bar)
BK 212
[lb/h]
15400
[kg/h]
7000
Capacity Charts
The charts show the maximum capacities for hot and cold
condensate. The capacities are a function of differential
pressure or the difference between inlet and outlet pressures for the trap.
5000
10000
3000
5000
2000
4000
3000
1000
2000
800
600
500
1000
400
800
300
600
500
200
Capacity
400
300
100
200
[bar]
8 10
20
30
45
60
80 110
200 250
[psi]
60 80 100
DPMX
200
300 400
2000
3625
S t an d ar d S p ar e P ar t s
Socket-weld ends (Class 9000)
Item
Number
56
Descri ption
B K 212
B ody
Cover
0 8 94 56
Regulator
3 7 18 62
Cover Gasket
3 7 40 09
Strainer
0 9 63 45
Cover Bolts
0 8 93 42
owserve.com
Application
The BK 212HT is designed for high pressure/high
temperature drip applications including steam main drip,
turbine drain, etc. Excellent for superheated steam drip
applications.
3625
psi
Maximum p
(250 bar)
BK 212HT
1SFTTVSF
<CBS > <QTJ>
[psig]
[barg]
Related Temperature
Maximum Differential Pressure
2350
162
1076
580
%ND #ONNECTIONS
$IMENSIONS AND
7EIGHTS
.OMINAL 3IZES
$IMENSIONS
!PPROX 7EIGHT
;INCH=
;MM=
, ;INCH=
;MM=
;LBS=
;KG=
&LANGED
3CREWED
3OCKET
7ELD
"UTT
7ELD
57
3625
psi
Maximum p
(250 bar)
BK 212HT
[lb/h]
15400
10000
5000
[kg/h]
7000
Capacity Charts
The chart shows the maximum capacities for hot and cold
condensate. The capacities are a function of differential
pressure or the difference between inlet and outlet pressures for the trap.
5000
3000
2000
4000
3000
1000
2000
800
600
500
1000
400
800
300
600
500
200
Capacity
400
300
100
200
[bar]
8 10
20
30
45
60
80 110
200 250
[psi]
60 80 100
DPMX
200
300 400
2000
Item
Number
1
2
3
4
5
6
7
58
3625
Material/Test Certificates
All inspection requirements must be stated at time of order.
Test certificates can be issued on request in accordance
with EN 10204 2.2 and -3.1B. Heat codes from Body and
cover are required.
Description
Body
Cover
Regulator
Cover Gasket
Strainer
Cover Bolts
Cover Bolts Nuts
BK 212HT
089456
371862
374009
096345
013050
012073
owserve.com
BK 212EX
Maximum p
(250 bar)
Application
The BK 212EX steam trap is used for low capacity drip leg
applications such as superheated turbines, sootblowers and
general distribution. The dissimilar stainless steel-shaped
bimetallic plates and the specially staged titanium nozzle
assure long-lasting service and zero steam loss operation
even under superheat or water hammer conditions.
3625
psi
0RESSURE
;BAR = ;PSI=
;&= 4EMP
;#= 4EMP
[psig]
[barg]
Related Temperature
Maximum Differential Pressure
2612
180
1090
588
%ND #ONNECTIONS
$IMENSIONS AND
7EIGHTS
.OMINAL 3IZES
$IMENSIONS
!PPROX 7EIGHT
;INCH=
;MM=
, ;INCH=
;MM=
;LBS=
;KG=
&LANGED
3CREWED
3OCKET
7ELD
"UTT
7ELD
59
3625
psi
BK 212EX
Maximum p
(250 bar)
10000
5000
[kg/h]
7000
Capacity Charts
The charts show the maximum capacities for hot and cold
condensate. The capacities are a function of differential
pressure or the difference between inlet and outlet pressures for the trap.
5000
3000
2000
4000
3000
1000
2000
800
600
500
1000
400
800
300
600
500
200
Capacity
400
300
100
200
[bar]
8 10
20
30
45
60
80 110
200 250
[psi]
60 80 100
DPMX
200
300 400
2000
60
Item
Number
1
2
3
4
5
6
3625
Description
Body
Cover
Regulator
Cover Gasket
Strainer
Cover Bolts
BK 212EX
374831
370490
374009
096345
Upon Request
owserve.com
BK 15
320
psi
Maximum p
(22 bar)
Application
The BK 15 steam trap is used for medium capacity applications such as heat exchangers, large air preheaters, tank
heaters, etc. The stainless steel bimetallic plates and the
staged nozzle assure long-lasting service and zero steam
loss operation even under superheat conditions and waterhammer conditions.
Features and Benefits
Forged carbon steel body.
Pressure assisted fail open design.
Modulating bimetallic regulator with fatigue-free stainless
steel plates. No adjustment required.
In-line adjustment available for characterization to process
conditions and effects of back pressure.
Discharges hot condensate at approximately 18F (10C)
below saturation temperature throughout its operating
range. One internal regulator for all pressure ranges.
Operation is unaffected by water hammer or superheat.
Self draining will not freeze when installed in gravity
drainage position.
Automatically vents non-condensables and has a high
(>3:1) cold water capacity for rapid start-up.
[psig]
[barg]
464
319
32
22
725
[ F] 482
o
385
[ C] 250
320 psig (22 barg)
o
Related Temperature
Maximum Differential Pressure
$IMENSIONS AND
7EIGHTS
.OMI NAL 3I ZE
&ACE TO &ACE
"UTT WELD
;MM=
, ;)NCH=
;MM=
$ ;I NCH=
;MM=
B ;I NCH=
K ;I NCH=
;MM=
G ;I NCH=
;LBS=
;KGS=
;MM=
3OCKET WELD
.UMBER OF "OLTS
&LANGED TO
!.3)
L ;I NCH=
&LANGED TO
!.3)
;MM=
%ND #ONNECTIONS
&LANGED TO
$).
;)NCH=
;MM=
Materials
Body and Cover ASTM A105 (DIN 1.0460)
210
14.5
842
450
61
320
psi
Maximum p
(22 bar)
BK 15
;LBH=
;KGH=
#APACITY
Capacity Charts
The charts show the maximum capacities for hot and cold
condensate. The capacities are a function of differential
pressure or the difference between inlet and outlet pressures for the trap.
%0-8
1SFTTVSF
<CBS> <QTJ>
;BAR=
;PSI=
62
Descri pti on
Butt-weld ends
B K 15
B od y
C over
0 9 68 87
C over Plug
0 1 36 42
Regulator
0 9 88 47
3 7 19 08
Strai ner
0 9 68 91
C over Gasket
0 8 70 95
C over
8
Bolts
Nuts
014405
0 1 31 24
How to Order
Specify trap, end connection size and type.
For Example: BK 15 1" NPT
owserve.com
Application
The BK 27 steam trap is used for higher pressure mediumcapacity applications such as heat exchangers, large air
preheaters, tank heaters, etc. The stainless steel bimetallic
plates and the staged nozzle assure long lasting service
and zero steam loss operation even under superheat or
waterhammer conditions.
BK 27
650
psi
Maximum p
(45 bar)
[psig]
[barg]
Related Temperature
Maximum Differential Pressure
812
682
56
47
752
[oF] 572
400
[oC] 300
650 psig (45 barg)
653
45
842
450
$IMENSIONS AND
7EIGHTS
.OMINAL 3IZES
$IMENSIONS
!PPROX 7EIGHT
%ND #ONNECTIONS
&LANGED
;INCH=
;MM=
, ;INCH=
;MM=
( ;INCH=
;MM=
;LBS=
;KG=
3OCKET
7ELD
"UTT
7ELD
63
650
psi
Maximum p
(45 bar)
[lb/h]
52800
[kg/h]
24000
50000
21000
20000
45000
BK 27
40000
30000
Capacity Charts
The charts show the maximum capacities for hot and cold
condensate. The capacities are a function of differential
pressure or the difference between inlet and outlet pressures for the trap.
Curve 1 shows the maximum capacity when discharging
hot condensate that is 18F (10C) below steam saturation temperature. For example, at a differential pressure
of 400 psi the maximum hot capacity is approximately
5,000 lb/hr.
12000
26000
10000
8000
7000
15000
6000
13000
5000
10000
9000
4000
8000
1
Capacity
4000
1000
2000
8 10
60 80 100
%PMX
20
200
45 [bar]
30
300 400
600 [psi]
%
&
'
Descripti on
BK 27
C over Plug
0 9 61 78
0 0 09 92
Regulator
0 9 88 5 4
Strai ner
0 9 70 18
C over Gasket
0 8 65 36
C over Bolts
014231
NPT
SW, BW
How to Order
Specify trap, end connection size and type.
For Example: BK 27 1" NPT
64
owserve.com
DK 36/A7
Maximum p
(29 bar)
Application
The ECONOline DK 36/A7 steam trap is used for low
capacity applications such as drip and tracing. The trap is
attached to the universal connector by means of 2 hex head
bolts and can be used on any existing connectors in your
piping system.
420
psi
ECONOline
L1
L
%JNFOTJPOTBOE
8FJHIUT
/ PNJOBM4J[FT
%JNFOTJPOT
"QQSPY 8FJHIU
XPDPOOFDUPS
"QQSPY 8FJHIU
XJUIDPOOFDUPS
<JODI>
<NN>
%<JODI>
<NN>
-<JODI>
<NN>
-<JODI>
<NN>
)<JODI>
<NN>
<MCT>
<LH>
<MCT>
<LH>
&OE$POOFDUJPOT
4DSFXFE4PDLFU8FME
65
420
psi
Maximum p
(29 bar)
[lb/h]
2000
[kg/h]
1000
800
1000
800
600
600
500
400
300
500
400
200
Capacity
300
200
DK 36/A7
100
80
150
2
20
8 10
30 40 50 60 80100
20
29 [bar]
%PMX
Related Temperature
Maximum Differential Pressure
Butt weld
How to Order
For the trap only:
Socket-weld
[psig]
[barg]
[oF]
[oC]
719
49.6
68
20
613
519
42.3
35.8
212
392
100
200
320 psig (22 barg)
458
31.6
572
300
421
29
842
450
DK 36/A7
For the trap and connector:
Specify trap, end connection size and type.
For Example: DK 36/A7 NPT
2.9"
75 mm
66
owserve.com
DK 47
Maximum p
(42 bar)
Application
The DK 47 steam trap is used for low capacity applications
such as distribution line drips and tracers.
609
psi
"'
Trap Types
DK 47L: Trap is available in 3 8" to 1" body sizes. All body
sizes have the same low condensate capacity.
DK 47H: Trap is available in " to 1" body sizes. The
condensate capacity increases with the larger body size.
Materials
Body ASTM A743 CA40F (DIN 1.4027)
Cap AISI 420 (DIN 1.4021)
Disc AISI 420 (DIN 1.4021)
0QUJPOBM
#MPX0GG
7BMWF
C
L
H
A.F.
Approx. Weight
[inch]
[mm]
[inch]
[mm]
[inch]
[mm]
[inch]
[mm]
[inch]
[mm]
[lbs]
[kg]
Screwed
3/8
10
2.5
64
3.1
78
4.1
104
4.1
36
1.7
0.8
1/2
15
2.5
64
3.1
78
4.1
104
1.6
41
1.7
0.8
3/4
20
2.7
68
3.5
90
4.4
111
1.6
41
2.2
1.0
End Connection
Butt-Weld
1
25
2.8
72
3.7
95
4.9
124
2.2
55
3.5
1.6
1/2
15
4.1
103
7.4
187
2.8
70
4.1
36
3.1
1.4
3/4
20
4.3
110
8.8
224
3.0
77
1.6
41
4.0
1.8
Socket-Weld
1/2
15
4.1
103
7.4
187
2.8
70
1.6
41
3.1
1.4
3/4
20
4.3
110
8.8
224
3.0
77
2.2
55
4.0
1.8
67
609
psi
Maximum p
(42 bar)
[lb/h]
4000
[kg/h]
2000
3000
2000
1" H
1000
800
1000
H
3/4"
600
500
"H
1/2
400
The set of curves show the capacity for each type of steam
trap in the DK 47 series. The L denotes low capacity,
where traps with different end connection sizes all have the
same low capacity. The H denotes high capacity, where
the trap capacity increases with increasing end connection
size.
800
600
500
400
300
"L
3/4
",
1/2
",
8
/
3
200
Capacity
300
200
DK 47
100
80
60
100
40
[bar]
0.7
10
$PMX
20
30 40
5 6
60
8 10
80 100
16 20
200
28
300 400
42
609
[psi]
Material/Test Certificates
All inspection requirements must be stated at time of order.
Test certificates can be issued on request in accordance
with EN 10204 2.2 and -3.1B. Body and Cap heat codes
are required.
Available End Connections
Screwed sockets: NPT, BSP
Socket-weld, Butt-weld
How to Order
Specify trap and end connection size.
For Example: DK 47H " NPT
68
Item
Butt-Weld
Number
Description Screwed Socket-Weld
1
Disc
3/8" - 1" L 372708
1/2" H 372716
999716
3/4" H 372724
999717
1" H 372733
999718
2
Strainer
372710
999710
3
Blow-off Valve
999711
owserve.com
DKT 47
Maximum p
(42 bar)
Application
The DKT 47 steam trap is used for low capacity applications such as drip and tracing where a positive indication
of operational mode is required. The temperature probe
provides an accurate readout of internal trap conditions.
Performance can be quantified and displayed in a DCS
system.
609
psi
"'
)
$
Materials
Body and Cover ASTM A743 CA40F (DIN 1.4027)
Cap AISI 416
Nominal Sizes
Dimensions
C
L
H
A.F.
Approx. Weight
[inch]
[mm]
[inch]
[mm]
[inch]
[mm]
[inch]
[mm]
[inch]
[mm]
[lbs]
[kg]
Screwed
3/8
10
2.5
64
3.1
78
4.1
104
4.1
36
1.7
0.8
1/2
15
2.5
64
3.1
78
4.1
104
1.6
41
1.7
0.8
3/4
20
2.7
68
3.5
90
4.4
111
1.6
41
2.2
1.0
End Connection
Butt-Weld
1
25
2.8
72
3.7
95
4.9
124
2.2
55
3.5
1.6
1/2
15
4.1
103
7.4
187
2.8
70
4.1
36
3.1
1.4
3/4
20
4.3
110
8.8
224
3.0
77
1.6
41
4.0
1.8
Socket-Weld
1/2
15
4.1
103
7.4
187
2.8
70
1.6
41
3.1
1.4
3/4
20
4.3
110
8.8
224
3.0
77
2.2
55
4.0
1.8
69
609
psi
Maximum p
(42 bar)
DKT 47
Available Sizes: 38", ", " and 1"
(DN 10, 15, 20 and 25)
Power Requirements
Input: 530 VDC
Material/Test Certificates
All inspection requirements must be stated at time of order.
Test certificates can be issued on request at extra cost in
accordance with EN 10204 2.2 and -3.1B. Body and Cover
heat codes are required. Range settings and calibration
certificate are supplied with each DKT 47.
Description
Screwed
Disc
3/8" - 1" L 372708
1/2" H 372716
3/4" H 372724
1" H 372733
Strainer
372710
Temperature
Probe with Plug
902003PD
Butt-Weld
Socket-Weld
999716
999717
999718
999710
902003PD
How to Order
Specify end connection size and type.
Specific pressure and temperature conditions must be
provided for each DKT 47 in order for Flowserve Gestra to
properly calibrate the output (not required for DTS option).
Specify 420 mA , 010 VDC or DTS output.
Flowserve Gestra self-monitoring steam traps are available
in other models for various pressures and temperatures.
Please consult your local Flowserve Gestra representative
for details.
NOTE: All specifications for the DKT 47 steam trap are
identical to the DK 47. The temperature probe does not
alter the pressure or temperature ratings. Please consult
the DK 47 data sheet for additional information.
70
owserve.com
DK 57
609
psi
Maximum p
(42 bar)
Application
The DK 57 steam trap is used for low capacity applications
such as distribution line drips and tracers.
Trap Types
DK 57L: Trap is available in 3 8" to " body sizes. All body
sizes have the same low condensate capacity.
DK 57H: Trap is available in " to 1" body sizes. The
condensate capacity increases with the larger body size.
Features and Benefits
Forged stainless steel body.
End-to-end dimensions identical to most competitive
models.
Pr es s u r e / Tem p er at u r e Rat i n g s
Maximum Operati ng
Pressure
Maximum Allowable
Pressure
Maximum Allowable
Temperature
[psig]
6 09
[barg]
42
[psig]
9 14
[barg]
63
[F]
7 52
[C]
4 00
End Connection
Screwed
[inch]
[mm]
L [inch]
[mm]
H [inch]
[mm]
A.F. [inch]
[mm]
[lbs]
[kg]
3/8
10
2.2
55
1.9
48
1.4
36
1.0
0.5
1/2
15
2.8
70
2.0
52
1.6
41
1.3
0.6
3/4
20
3.1
80
2.5
63
1.6
41
2.0
0.9
1
25
3.5
90
2.9
74
2.2
55
3.1
1.4
71
609
psi
Maximum p
(42 bar)
DK 57
[lb/h]
4000
[kg/h]
2000
3000
2000
1" H
1000
800
1000
H
3/4"
600
500
The set of curves show the capacity for each type of steam
trap in the DK 57 series. The L denotes low capacity,
where traps with different end connection sizes all have the
same low capacity. The H denotes high capacity, where
the trap capacity increases with increasing end connection
size.
"H
1/2
400
800
600
500
400
300
L
/4"
,3
/2"
,1
"
3/8
200
Capacity
300
200
100
80
60
100
40
[bar]
0.7
10
$PMX
20
30 40
5 6
60
8 10
16 20
80 100
200
28
300 400
42
609
[psi]
3 T AN D AR D 3 P AR E 0 AR T S
)TEM
.UMBER
$ ESCRIPTI ON
$ +
"ODY
$ I SC
,
(
(
(
72
"ONNET
owserve.com
Operation
Air-venting when system is cold
(start-up condition).
73
Thermostatic bellows
For automatic air-venting
(Duplex control). Without
bellows (Simplex control)
for cold fluids.
Upper plug
Installation of manual
vent valve or air balance
possible.
Bolted cover
Closed or sightglass cover
(water-level indicator).
Control unit
Easy maintenance after
opening cover. Complete
unit may be changed
without removing body
from pipeline.
Deflector
Guarantees the deflection
of the condensate stream
and reduces wear on the
trap body.
Lower Plug
Draining of trap or for
installation of lifting
lever.
74
owserve.com
Maximum p
(21 bar)
Application
The UNA 14 and UNA 16 are designed for low to medium
capacity applications such as (inside) drips, small unit
heaters, heat exchangers, etc., where maximum air
handling, hot discharge and modulating operation are
required. Very useful for low differential applications such
as HVAC.
305
psi
Trap Types
UNA 14: Cast Steel, 185 Maximum p
-
UNA 14
Body Style
[psig]
[barg]
[oF]
[oC]
Related Temperature
[psig]
[barg]
[oF]
[oC]
262
17.8
482
250
221
15
662
350
UNA 16
Body Style
Maximum Service Pressure
285
19.4
392
200
Materials
UNA 14 Body - ASTM A105 (DIN 1.0460)
Cover - A536 60-40-48 (EN-JS-1049)
368
25
68
20
Related Temperature
254
17.3
68
20
203
13.8
392
200
UNA 16A
150
10.2
572
300
Flanged L
Butt-Weld L
284
19.3
68
20
96
6.5
752
400
250
17
212
100
206
14
392
200
Nominal Sizes
[inch]
1/2
3/4
[mm]
15
20
25
[inch]
5.9
5.9
6.3
[mm]
150
150
160
[inch]
7.9
7.9
7.9
[mm]
200
200
200
Socketweld L
[inch]
3.7
3.7
3.7
Screwed
Approx. Weight
[mm]
95
95
95
[lbs]
13
14
15
Flanged
[kg]
6.5
10
10
Screwed
4.5
4.5
1.5
[kg]
150
10.2
572
300
75
305
psi
Maximum p
(21 bar)
;KGH=
/