Sie sind auf Seite 1von 20

JEREMIAS GROUP

CE MARK according to EN 1856-1 / 2

www.jeremias.de/int

CE MARK according to EN 1856-1 / 2

WHAT DOES THE CE MARK MEAN FOR STAINLESS STEEL CHIMNEY SYSTEMS?

The CE MARK is the symbol obligatory since


April 2005 that certifies that a stainless steel
chimney is in accordance with the EN 1856-1.
This standard specifies the performance
requirements for rigid single and multi-wall system
chimney products with metallic liners (chimney
sections, chimneys fittings and terminals,
including supports) used to convey the products
of combustion from appliances to the outside
atmosphere.
It also specifies the requirements for marking,
manufacturers instructions, product information
and evaluation of conformity of the product to the
standard.
www.jeremias.de/int

The EN 1856-1 does not apply to self-standing


chimneys.
30.08.2013

Page: 2

CE MARK according to EN 1856-1 / 2

WHAT DOES THE CE MARK MEAN FOR STAINLESS STEEL CHIMNEY SYSTEMS?

The manufacturer is obliged to realize the


complete initial test of the chimney in a laboratory,
and moreover, a Certified Body will:
1.

2.

-annually check that the manufactured


product has the same quality as the tested
one
-perform the quality control of the production
process to ensure that it will satisfy the CE
requirements, specified in the FPC (Factory
Production Control).

The CE MARK of the stainless steel chimney can


only be granted by a Certified Body.
www.jeremias.de/int

The CE Mark enables the product to circulate


freely in the European market, but each country
could have its own installation rules
30.08.2013

Page: 3

CE MARK according to EN 1856-1 / 2

CE MARK LABEL

1.
2.
3.
4.
5.
6.
7.

30.08.2013

Standard
Temperature Level
Pressure Level
Condensate resistance
Corrosion resistance
Flue liner material specification
Soot fire resistance (O: no; G:yes)

www.jeremias.de/int

Page: 4

CE MARK according to EN 1856-1 / 2

CE MARK LABEL
1- Standard
EN 1856-1 for vertical chimneys
EN 1856-2 for connecting pipes
2- Temperature Level
Maximum working temperature.
The temperature used in the test and the resulting temperature levels achieved are as follows:

As guidance, the temperature ratings applicable are:


T200: all gas and oil applications (including condensing)
T450: solid fuels and multifuels
T600: power generators and CHPs
30.08.2013

www.jeremias.de/int

Page: 5

CE MARK according to EN 1856-1 / 2

CE MARK LABEL
3- Pressure Level
Admitted overpressure inside the flue, with its corresponding leakage rate

As guidance, the pressure ratings applicable are:


N1: natural draught installations
P1: forced draught boiler installations
H1: power generators , CHPs and micro CHPs
30.08.2013

www.jeremias.de/int

Page: 6

CE MARK according to EN 1856-1 / 2

CE MARK LABEL
4- Condensate resistance
Suitability of the flue for wet or dry conditions.
D: the flue is suitable only for dry conditions. It does not resist condensate.
W: the flue is suitable whether for dry and wet conditions. It resists condensate water inside.
5- Corrosion resistance
Level of corrosion resistance due to the products of combustion of the different kinds of
combustibles and different working conditions (dry or wet)
V1: Tested and approved as resistant to attack from products of combustion from gas.
V2: Tested and approved as resistant to attack from products of combustion from light oil (sulphur
content <0,2%) and natural wood in dry conditions, and from gas in wet conditions (condensing
appliances)
V3: Tested and approved as resistant to attack from products of combustion from heavy oil (sulphur
content >0,2%), solid fuels and peat in dry conditions
www.jeremias.de/int
Vm: Not tested. The manufacturer certifies only the material used in the inner wall by the quality
certificate of the steel. For flues with this class there are specific regulations in each country indicating
what material is suitable for each installation. As general guidance the stainless steel AISI 304 is
equivalent to class V1, and the stainless steel AISI 316L is equivalent to classes V2 and V3
30.08.2013
Page: 7

CE MARK according to EN 1856-1 / 2

CE MARK LABEL
6- Flue liner material specification
The material of the inner liner must be specified and its minimum thickness as well:

After that the minimum thickness of this inner liner is specified as follows:
040: 0,4mm
050: 0,5mm
060: 0,6mm
30.08.2013

www.jeremias.de/int

Page: 8

CE MARK according to EN 1856-1 / 2

CE MARK LABEL
7- Soot fire resistance (O: no; G: yes)
Soot fire resistance and minimum distance to combustible material
It is expressed as G if the flue System has been tested, and as O if not. This classification is followed
by the minimum distance (in mm) to combustible material.
The test is a thermal shock of 1.000C during 30 minutes during which the System must endure and
the temperature of combustible materials placed at the declared distance must not exceed 100C at an
ambient temperature of 20C.
The systems with O classification have not passed this test, so they cannot be used for any
installation where the products of combustion contain soots (solid fuels, multifuels...). For low
temperature applications, for instance room sealed boilers, where joints are used

www.jeremias.de/int

30.08.2013

Page: 9

CE MARK according to EN 1856-1 / 2

CE MARK LABEL
8- Other declared characteristics:

The characteristics of the previous points must be indicated in all documents of CE marking
Hereinafter is a list of other characteristics that only appear in the DoP. (Declaration of Performance)
Compressive strength (height for installation)
Flow resistance of chimney sections fittings and terminals
Minimum thermal resistance
Flexural tensile strength
Maximum distances between supports in non vertical installation
Wind load resistance (maximum distances between fixing points and freestanding above the last one)
Freeze thaw resistance

www.jeremias.de/int

30.08.2013

Page: 10

Jeremias Group Quality

JEREMIAS GROUP QUALITY COMPROMISE


Jeremias is one of the world`s leading manufacturers of flue and chimney
systems for the exhaust of gases and ventilation, covering all kind of domestic,
commercial and industrial applications.
Jeremias product range include 60 different CE certified systems covering
commercial and domestic applications complemented by freestanding Industrial
steel chimneys up to 3 meter diameter.
Besides this compulsory CE Certification, Jeremias has also special
certifications and listings needed in specific countries under i.e.; BS, Hetas,
Swiss, Russian or US standards.
For further information, Jeremias can supply technical guidance on various
www.jeremias.de/int
standards including the latest version of the European Standard 1856-1/2:2010.
Please contact our certification department.
30.08.2013

Page: 11

Jeremias Group

APPROVALS & CERTIFICATIONS

www.jeremias.de/int

30.08.2013

Page: 12

System overview

DOUBLE WALL SYSTEMS

DW AL

30.08.2013

DW KL

DW-KL

DW VISION

www.jeremias.de/int

DW MAMMUT

Page: 13

System overview

SINGLE WALL SYSTEMS

EW-FU

30.08.2013

EW-ECO

EW-ALBI

EW-Line FLEX

www.jeremias.de/int

EW-LAS

Page: 14

System overview

SINGLE WALL SYSTEMS

EW-KL

30.08.2013

SV-EI-30

EW-VH

EW-PPS

www.jeremias.de/int

EW-PPS-FLEX

Page: 15

System overview

PLASTIC & CONCENTRIC & DOUBLE WALL SYSTEMS

CASCADE

30.08.2013

TWIN-PL

TWIN-P

DW ECO2.0

www.jeremias.de/int

DW FU

Page: 16

System overview

SHAFTS & WALL-, FLOOR-

FUMOLUX A/F

30.08.2013

FUMOLUX-P

AND

ROOF SLEEVES

FURADO

LUX FIX/VARIO

www.jeremias.de/int

LUX ECO

Page: 17

System overview

SHARE COLLECTIVE CHIMNEY & VENTILATION SYSTEMS

SED

30.08.2013

SEE

SET

CLV

SVC

www.jeremias.de/int

Page: 18

System overview

STOVE PIPE & ACCESSORIES, VALVES, DAMPERS, SILENCERS

FERROLUX

30.08.2013

AIR SUPPLY SYSTEM PELLET PIPE

ACCESSORIES

www.jeremias.de/int

SILENCERS

Page: 19

Jeremias Group

INTERNATIONAL PROJECTS

www.jeremias.de/int

Das könnte Ihnen auch gefallen