Sie sind auf Seite 1von 5

Vibration isolators

Description

How to specify

Vibration isolators reduce generator set vibration and


noise transmission to the surrounding structure.

Lateral stability - Fully adjustable snubber inserts of oil


resistant synthetic rubber.

The isolation mountings shall consist of malleable cast


iron top and bottom housings incorporating one or more
steel springs and shall be provided with built-in leveling
bolts, elastomer pad and built-in resilient chocks to
control oscillation and withstand lateral forces in all
directions. They shall be pre-sized and installed in
accordance with the recommendations of the generator
set manufacturer. Not recommended in trailer-mounted
applications.

Construction - All housings are rugged enamel coated


grey cast iron per ASTMA 48 with 0.52" to 1.58" static
deflection.

Typical installation procedures for


spring type isolators

Noise absorption - 1/4" thick waffle-embossed non-skid


elastomer sound pad.

1. Position and secure isolators on a level surface under


equipment. Base rails should run the long length of
the isolator. When the generator set is mounted on a
sub-base fuel tank the vibration isolators must be
installed between the generator set and the fuel tank.

Korfund (series LK)


Level adjustment - External adjustment via single
electro-zinc plated bolt and lock nuts.

Springs - High carbon steel with corrosive resistant


finish powder coated springs.

Korfund (series CE)


Level adjustment - External adjustment via single
electro-zinc plated bolt and lock nuts.
Construction - All housings are shop-primed with a rust
inhibitor and are grey cast iron per ASTMA 48 with 0.74"
to 1.17" static deflection.
Noise absorption - 1/4" thick non-skid elastomer sound
pad.

2. Insert adjusting bolt with lock nut through equipment


and into threaded hole in isolator top housing.
3. Proceed to adjust isolators by turning adjusting bolt
several turns at a time alternately on each isolator until
equipment is raised uniformly. Then level as required.
4. Tighten lock nut firmly in place.
5. Isolators are now properly adjusted and ready for
equipment to be operated.

Springs - Powder coated steel springs.

2011 Cummins Power Generation Inc. All rights reserved. Cummins Power Generation and Cummins are registered trademarks of
Cummins Inc. Our energy working for you. is a trademark of Cummins Power Generation. Specifications are subject to change without notice.
AC-138l (6/11) Page 1 of 5

Model to isolator part number reference


Model
DFAA
DFAB
DFAC
DFBF
DFCB
DFCC
DFCE
DFEB
DFEC
DFED
DFEG
DFEH
DFEJ
DFEK
DFGA
DFGB
DFGE
DFHA
DFHB
DFHC
DFHD
DFJC
DFJD
DFLB
DFLC
DFLE
DFMB
DGBB
DGBC
DGCA
DGCB
DGCC
DGCG
DGDA
DGDB
DGDK
DGEA
DGFA
DGFB
DGFC
DGFS
DGGD
DGHD
DGHE
DKAC
DKAE
DKAF
DNAA
DNAB
DNAC
DNAD
DNAE
DNAF
DQAA
DQAB
DQAD

Quantity
isolators
required
4
4
4
4
4
4
4
6
6
6
6
6
6
6
8
8
8
10
10
10
10
12
12
12
12
12
12
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

"LK"
isolator
P/N
0402-0222
0402-0222
0402-0222
0402-0427
0402-0427
0402-0427
0402-0427
0402-0427
0402-0427
0402-0427
0402-0222
0402-0222
0402-0222
0402-0222
0402-0222
0402-0222
0402-0222
0402-0222
0402-0222
0402-0222
0402-0222
0402-0222
0402-0222
0402-0427
0402-0427
0402-0427
0402-0427
0402-0234
0402-0234
0402-0234
0402-0234
0402-0234
0402-0234
0402-0222
0402-0222
0402-0222
0402-0222
0402-0222
0402-0222
0402-0222
0402-0222
0402-0234
0402-0234
0402-0234
0402-0220
0402-0220
0402-0220
0402-0202 (pad)
0402-0202 (pad)
0402-0202 (pad)
0402-0202 (pad)
0402-0202 (pad)
0402-0202 (pad)
0402-0222
0402-0222
0402-0222

"CE"
isolator
P/N
0402-0691-02
0402-0691-02
0402-0691-02
0402-0691-04
0402-0691-04
0402-0691-04
0402-0691-04
0402-0691-04
0402-0691-04
0402-0691-04
0402-0691-02
0402-0691-02
0402-0691-02
0402-0691-02
0402-0691-02
0402-0691-02
0402-0691-02
0402-0691-02
0402-0691-02
0402-0691-02
0402-0691-02
0402-0691-02
0402-0691-02
0402-0691-04
0402-0691-04
0402-0691-04
0402-0691-04
0402-0690-12
0402-0690-12
0402-0690-12
0402-0690-12
0402-0690-12
0402-0690-13
0402-0690-14
0402-0690-14
0402-0690-14
0402-0690-15
0402-0690-15
0402-0690-15
0402-0690-15
0402-0690-15
0402-0690-12
0402-0690-12
0402-0690-12
0402-0690-11
0402-0690-11
0402-0690-11
N/A
N/A
N/A
N/A
N/A
N/A
0402-0691-02
0402-0691-02
0402-0691-02

Quantity
isolators
required
4
4
4
4
8
8
8
4
4
4
10
10
10
10
12
12
6
6
10
10

"LK"
isolator
P/N
0402-0222
0402-0222
0402-0222
0402-0222
0402-0427
0402-0427
0402-0427
0402-0222
0402-0222
0402-0222
0402-0222
0402-0222
0402-0222
0402-0222
0402-0427
0402-0427
0402-0222
0402-0222
0402-0750-01
0402-0750-01

"CE"
isolator
P/N
0402-0691-02
0402-0691-02
0402-0691-02
0402-0691-02
0402-0691-04
0402-0691-04
0402-0691-04
0402-0691-02
0402-0691-02
0402-0691-02
0402-0691-02
0402-0691-02
0402-0691-02
0402-0691-02
0402-0691-04
0402-0691-04
0402-0691-02
0402-0691-02
N/A
N/A

DQKB Rmt
Rad/Ht Exch

0402-0750-01

N/A

DQKB Set Mtd


Rad

10

0402-0750-01

N/A

DQKC Rmt
Rad/Ht Exch

0402-0750-01

N/A

DQKC Set Mtd


Rad

10

0402-0750-01

N/A

DQKD Rmt
Rad/Ht Exch

0402-0750-01

N/A

DQKD Set Mtd


Rad

10

0402-0750-01

N/A

0402-0750-01

N/A

10
See last pg
See last pg

0402-0750-01
N/A
N/A

N/A
N/A
N/A

DQLC Rmt Mtd


Rad
10

0402-0750-01

N/A

DQLC Set Mtd


Rad
DSFAA
DSFAB
DSFAC
DSFAD
DSFAE
DSGAA
DSGAB
DSGAC
DSHAA
DSHAB
DSHAC
DSHAD
DSHAE
DSHAF
DSKAA

0402-0750-01
0402-0234
0402-0234
0402-0234
0402-0234
0402-0234
0402-0222
0402-0222
0402-0222
0402-0222
0402-0222
0402-0222
0402-0222
0402-0222
0402-0222
N/A

N/A
0402-0690-12
0402-0690-12
0402-0690-12
0402-0690-12
0402-0690-12
0402-0690-15
0402-0690-15
0402-0690-15
0402-0690-15
0402-0690-15
0402-0690-15
0402-0690-15
0402-0690-15
0402-0690-15
0402-0690-11

Model
DQAE
DQAF
DQBA
DQBB
DQCA
DQCB
DQCC
DQDAA
DQDAB
DQDAC
DQFAA
DQFAB
DQFAC
DQFAD
DQGAA
DQGAB
DQHAA
DQHAB
DQKAA
DQKAB

DQKH Rmt
Rad/Ht Exch
DQKH Ht Exch
DQLA
DQLB

12
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

Our energy working for you.


www.cumminspower.com
2011 Cummins Power Generation Inc. All rights reserved. Cummins Power Generation and Cummins are registered trademarks of
Cummins Inc. Our energy working for you. is a trademark of Cummins Power Generation. Specifications are subject to change without notice.
AC-138l (6/11) Page 2 of 5

Model to isolator part number reference (continued)

Model
DSKAB
DSKBA
DSKCA
GGDB
GGFB
GGFC
GGFD
GGFE
GGHB
GGHC
GGHD
GGHE
GGHF
GGHG
GGHH
GGKB
GGKC
GGKD

Quantity
isolators
required
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

"LK"
isolator
P/N
N/A
N/A
N/A
0402-0202 (pad)
0402-0234
0402-0234
0402-0234
0402-0234
0402-0222
0402-0222
0402-0222
0402-0222
0402-0222
0402-0222
0402-0222
0402-0222
0402-0222
0402-0222

"CE"
isolator
P/N
0402-0690-11
0402-0690-11
0402-0690-11
0402-0690-12
0402-0690-12
0402-0690-12
0402-0690-12
0402-0690-14
0402-0690-14
0402-0690-14
0402-0690-14
0402-0690-14
0402-0690-14
0402-0690-14
0402-0690-15
0402-0690-15
0402-0690-15

Quantity
isolators
required
4
4
8
8
8
4
4
4
4
4
4
8
8
8
8
8
8
10
10

Model
GGLA
GGLB
GGMA
GGMB
GGMC
GGPA
GGPB
GGPC
GNAA
GNAB
GNAC
GQKA
GQMA
GQMB
GQNA
GQNB
GQNC
GQPB
GQPC

"LK"
isolator
P/N
0402-0222
0402-0222
0402-0202 (pad)
0402-0202 (pad)
0402-0202 (pad)
0402-0234
0402-0234
0402-0234
0402-0202 (pad)
0402-0202 (pad)
0402-0202 (pad)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

"CE"
isolator
P/N
0402-0690-14
0402-0690-14
N/A
N/A
N/A
0402-0690-12
0402-0690-12
0402-0690-12
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

Korfund "LK" vibration isolators

Part number
0402-0220
0402-0222
0402-0234
0402-0427
0402-0431
0402-0750-01

Quantity
included
per part
number
1
1
1
1
1
1

Dimensions (in)
Max load
per isolator
(lbs)
A
B
C
D
600
5
9-1/2
8
6-7/8
2200
5
9-1/2
8
6-7/8
900
5
9-1/2
8
6-7/8
2400
5
9-1/2
8
6-7/8
4400
5
11-3/4
10-1/4 9-1/8
4800
5-7/8
11-3/4
10-1/4 9

F
5-3/4
4-3/8
4-3/8
5-3/4
5
5-7/8

9/16
9/16
9/16
9/16
11/16
5/8

G
5/8
5/8
5/8
5/8
3/4
3/4

Spring
constant
lbs/in
380
4260
1600
3300
8520
6600

Note: "LK" isolators are designed to be used with sub-base fuel tanks (159-1486-xx, 159-1512-xx, or 179-4921-xx).

Our energy working for you.


www.cumminspower.com
2011 Cummins Power Generation Inc. All rights reserved. Cummins Power Generation and Cummins are registered trademarks of
Cummins Inc. Our energy working for you. is a trademark of Cummins Power Generation. Specifications are subject to change without notice.
AC-138l (6/11) Page 3 of 5

Static
deflection
(in)
1.58
0.52
0.56
0.73
0.52
0.73

Korfund "CE" vibration isolators


Part number
0402-0690-11
0402-0690-12
0402-0690-13
0402-0690-14
0402-0690-15
0402-0691-02
0402-0691-04

Quantity
included per
Part number
4
4
4
4
4
2
2

Max load
per isolator
(lbs)
600
750
900
1100
1300
2200
2600

Dimensions (in)
A
3
3
3
3
3
3
3

B
7-1/2
7-1/2
7-1/2
7-1/2
7-1/2
10-1/4
10-1/4

C
6-1/2
6-1/2
6-1/2
6-1/2
6-1/2
9-1/4
9-1/4

D
4-1/2
4-1/2
4-1/2
4-1/2
4-1/2
7-1/2
7-1/2

E
5-1/4
5-1/4
5-1/4
5-1/4
5-1/4
5-5/8
5-5/8

F
5/8
5/8
5/8
5/8
5/8
5/8
5/8

G
1/2
1/2
1/2
1/2
1/2
5/8
5/8

Note: "CE" isolators cannot to be used with sub-base fuel tanks (159-1486-xx, 159-1512-xx, or 179-4921-xx).

Korfund vibration dampener pad


Part number
0402-0202

Impact load
2800 lbs (1270 kg)

Non-impact load
4200 lbs (1905 kg)

Our energy working for you.


www.cumminspower.com
2011 Cummins Power Generation Inc. All rights reserved. Cummins Power Generation and Cummins are registered trademarks of
Cummins Inc. Our energy working for you. is a trademark of Cummins Power Generation. Specifications are subject to change without notice.
AC-138l (6/11) Page 4 of 5

Spring
constant
lbs/In
513
707
881
1327
1758
2654
3516

Static
deflection
(in)
1.17
1.06
1.02
0.83
0.74
0.83
0.74

AVA limited rubber vibration isolator


Model
DQLA
DQLB

Part number
0179-3326-02
0179-3326-01

Quantity isolator kits required


1
1

Americas
1400 73rd Avenue N.E.
Minneapolis, MN 55432 USA
Phone: 763 574 5000
Fax: 763 574 5298

Kit contents
10 isolators with mounting hardware
12 isolators with mounting hardware

Europe, CIS, Middle East and Africa


Manston Park Columbus Ave.
Manston Ramsgate
Kent CT 12 5BF United Kingdom
Phone 44 1843 255000
Fax 44 1843 255902

Asia Pacific
10 Toh Guan Road #07-01
TT International Tradepark
Singapore 608838
Phone 65 6417 2388
Fax 65 6417 2399

Warning: Back feed to a utility system can cause electrocution and/or property damage. Do not connect generator sets to any building
electrical system except through an approved device or after building main switch is open.
Warning: For professional use only. Must be installed by a qualified service technician. Improper installation presents hazards of electrical
shock and improper operation, resulting in severe personal injury and/or property damage.

Our energy working for you.


www.cumminspower.com
2011 Cummins Power Generation Inc. All rights reserved. Cummins Power Generation and Cummins are registered trademarks of
Cummins Inc. Our energy working for you. is a trademark of Cummins Power Generation. Specifications are subject to change without notice.
AC-138l (6/11) Page 5 of 5