Efficient use of water resources is an important challenge in the 21st century. A global shortage of water resources is expected. Consideration of
the earth's environment has become more important in recent years, giving rise to a growing demand for reverse osmosis membranes.
Demonstrating excellent quality and high performance, Toray RO elements are functional membrane elements that were developed through
the polymer engineering of Toray, the first Japanese manufacturer of reverse osmosis membranes.
Toray RO element technology grew from Toray's abundant business experience. This experience has generated a broad product line spanning
many fields of application: ultra pure water production for semiconductor
and other industries, desalination of seawater, waste water treatment,
and recovery of valuable process materials in the food processing industry.
The experience, technology and expertise of Toray are being actively applied to all water-related needs around the world through the global operation of overseas affiliates and sales agents.
4. Compact configuration
Modules can be arranged in a three-dimensional configuration to provide
excellent space efficiency, so the space needed for installation can be
minimized.
Cross-Linked Polyamide
Composite Membrane
Cross-section of
Membrane
Supporting
layer
(60m)
Substrate
Applications
Water treatment for various usages of water.
Toray RO element produces the right water for a diverse
assortment of applications.
River water
Utilization of
permeate
Seawater
Refining and softening of water
Removal of water hardness and silica;
removal of trihalomethane,
its precursors,
and agricultural chemicals
City water
Recycling and closed systems
for various waste waters
Recycling of water in the semiconductor
and liquid crystal industries
Recycling of industrial waste
water, sewerage and
office waste water
Underground water
Ropur AG
Grabenackerstrasse 8 CH-4142 Mnchenstein 1, Switzerland
Tel: +41-61-415-87-10 Fax: +41-61-415-87-20
http://www.ropur.com/
Element Production:
Membranes and elements are manufactured and undertaken the quality assurance at Toray Ehime Plamt, which has
obtained
Quality Management System ISO 9001
certification, registration number; JQA0683, and Environmental Management
System ISO 14001 certification, registration number; JQA-EM0440.
Model
Description
8
4
8
8
8
4
8
4
4
4
8
8
8
8
inch
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
inch
99.5
99.5
99.4
99.5
99.7
99.75
99.75
99.75
99.5
99.5
99.7
99.4
99
99.7
99.5
99
99.4
99.4
99
27 (7,100)
7.5 (2,000)
32 (8,500)
32 (8,500)
8 (2,100)
5 (1,300)
36 (9,500)
26 (6,900)
30 (7,900)
21 (5,500)
4 (1,100)
19 (5,000)
16 (4,200)
6.5 (1,700)
37 (9,800)
27 (7,100)
26 (6,900)
32 (8,500)
22 (5,800)
m3/d (gpd)
0.35 (50)
0.35 (50)
0.35 (50)
0.5 (70)
0.75 (110)
0.75 (110)
0.75 (110)
0.75 (110)
0.75 (110)
0.75 (110)
1.5 (220)
0.75 (110)
5.5 (800)
5.5 (800)
5.5 (800)
5.5 (800)
0.75 (110)
0.75 (110)
1.5 (220)
1.5 (220)
1.0 (150)
1.5 (220)
0.75 (110)
1.0 (150)
1.5 (220)
1.5 (220)
1.0 (150)
MPa (psi)
Operating
Pressure
1,500
500
500
500
Pure water
Pure water
Pure water
Pure water
Pure water
500
500
1,500
500
500
500
1,500
1,500
1,500
1,500
500
1,500
1,500
1,500
1,500
mg/l NaCl
Feed
Concentration
25 (77)
25 (77)
25 (77)
25 (77)
25 (77)
25 (77)
25 (77)
25 (77)
25 (77)
25 (77)
25 (77)
25 (77)
25 (77)
25 (77)
25 (77)
25 (77)
25 (77)
25 (77)
25 (77)
25 (77)
25
25
25
25
25
(77)
(77)
(77)
(77)
(77)
25 (77)
25 (77)
25 (77)
25 (77)
(
F)
Temperature
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
10 (2.6)
10 (2.6)
10 (2.6)
80 (21)
80 (21)
80 (21)
80 (21)
80 (21)
20 (5.3)
12 (3.2)
3 (0.8)
12 (3.2)
12 (3.2)
3 (0.8)
20 (5.3)
80 (21)
80 (21)
80 (21)
80 (21)
20 (5.3)
80 (21)
80 (21)
20 (5.3)
80 (21)
80 (21)
20 (5.3)
20 (5.3)
20 (5.3)
80 (21)
80 (21)
80 (21)
80 (21)
80 (21)
Test Conditions
40
18 (4,800)
22 (5,800)
4.5 (1,200)
3.0 (440)
1,500
25 (77)
6
6
6
Size
55
55
55
35.2 (9,300)
3.0 (440)
1,500
25 (77)
25 (77)
25 (77)
l/min (gpm)
Brine Flow
40
40
40
95
27.2 (7,200)
3.0 (440)
1,500
1,500
1,500
pH
8
8
4
40
97
20.5 (5,400)
3.0 (440)
3.0 (440)
3.0 (440)
Performance
Product Flow
Rate
40
98
8.8 (2,300)
6.8 (1,800)
5.3 (1,400)
Diameter
40
95
97
98
(5,000)
(1,700)
(1,500)
(1,300)
(7,900)
40
40
40
19
6.5
5.5
4.75
30
4
4
4
Rejection
Range
Diameter
inch
4
8
Operating Pressure
Feed Concentration
Temperature
Test Conditions
Performance
Salt Rejection
pH
Recovery
15
15
15
15
15
15
15
15
15
15
15
Model
7
7
7
7
7
7
7
7
7
7
7
77 (25)
77 (25)
77 (25)
77 (25)
77 (25)
77 (25)
77 (25)
77 (25)
77 (25)
77 (25)
77 (25)
15
15
F (C)
2,000
2,000
2,000
2,000
500
500
500
500
500
500
500
7
7
mg/l NaCl
225 (1.55)
225 (1.55)
225 (1.55)
225 (1.55)
110 (0.76)
110 (0.76)
110 (0.76)
100 (0.69)
100 (0.69)
100 (0.69)
100 (0.69)
77 (25)
77 (25)
psi (MPa)
9,500 (36)
10,200 (39)
11,000 (42)
2,200 (8.3)
10,200 (39)
11,000 (42)
2,000 (7.6)
12,000 (45)
13,000 (49)
14,000 (53)
2,800 (10.5)
2,000
2,000
gpd (m3/d)
99.7
99.7
99.7
99.7
99.5
99.5
99.5
99.4
99.4
99.4
99.4
225 (1.55)
225 (1.55)
4
8
Medium
4
8
Low
Medium
TM720 -370
-400
-430
TM710
TMG20 -400
-430
TMG10
TMH20 -370
-400
-430
9,500 (36)
10,200 (39)
8
8
8
8
8
TMH10
99.7
99.7
7
7
7
7
7
4
-370
-400
77 (25)
77 (25)
77 (25)
77 (25)
77 (25)
TML20
32,000
32,000
32,000
32,000
32,000
800 (5.52)
800 (5.52)
800 (5.52)
800 (5.52)
800 (5.52)
High
6,000 (23)
6,500 (25)
1,200 (4.5)
1,600 (6.0)
5,600 (21)
99.75
99.75
99.75
99.70
99.75
High
High
TM820 -370
-400
TM810
TM810L
TM820H -370
UltraLow
Low Fouling
Standard
Seawater
SW
Standard
SW High