7ZZNA4266A

JAN-701B/901B/2000/1186NDC-1186-4xx
ECDIS/RPS/NWS
Software Update Manual for
Ver.00000056(V56)
in case that the current version is 00000050(V50)
Contents
z

Outline ...................................................................................................................................................1

PrefaceParts list in this work and estimate of working time................................................................2

1.

Flow chart ..............................................................................................................................................4

Step1Creating the software update CD.......................................................................................................5


Step2Confirming of latest Base CD, Update CD, and Cell permit(In case of using ENC) ...........................7
Step3Confirming latest C-Map database DVD and license (in case of using C-Map) .................................7
Step4Confirming of current software version. .............................................................................................8
Step5Software update...............................................................................................................................10
Step6Confirming of software update .........................................................................................................19
Step7Deleting of current ENC(Contain AVCS) charts (In the case of using ENC) ....................................20
Step8Re-install of ENC(Contain AVCS) charts (In case of using ENC).....................................................23
Step9Re-installing C-Map database (in case of using C-Map)..................................................................29
Step10Re-installing C-Map license (in case of using C-Map) ...................................................................33
Step11Confirming of Navigation & Planning ...........................................................................................35
Step12Storage of Update CD....................................................................................................................36
Step13Sending of software update result .................................................................................................36
Reference Document 1: Alarm Information of S-57/S63 Chart ...................................................................37
Request for sending of software update result............................................................................................43

7ZZNA4266A

z Outline
This is an update manual of Ver.00000056 from Ver.00000050 software for JAN-701B/901B/2000/1186,
NDC-1186-4xx.

In case of using ENC, Before update, confirm that there are latest Base CD and
Update CD.

In case of using C-map, it is necessary to re-install C-map database, and the


operation about C-map data updating is changed. So, before update, confirm that
there are latest database DVD.
A user map is not deleted by software update.

7ZZNA4266A

z PrefaceParts list in this work and estimate of working time


Parts list in this work and estimate of working time is described as follows. Confirm before visiting ship

Parts list in this work


Parts list

Remark

Software update CD

Download the files from TSMC or Amsterdam branch website and create the
software update CD according to Step:1

Software update manual

Print this document and take it for ship.

ENC/AVCS

Necessary in case of using ENC/AVCS

Data base CD

(Use it at ship after getting from customer)

ENC/AVCS

Necessary in case of using ENC/AVCS

Cell Permit CD

(Use it at ship after getting from customer)

C-Map Ed.3

Necessary in case of using C-Map Ed.3

Database DVD

(Use it at ship after getting from customer)

C-Map Ed.3

Necessary in case of using C-Map Ed.3

License file

(Use it at ship after getting from customer)

Estimate of working time (per 1 device)


The working time is different for the before version and using chart. Refer for work planning.
Before version

Chart

ENC
(including AVCS)

Working

breakdown

time

Remark

Updating software: about 10min

Chart installing

About

Deleting Playback data: about 5 min

time is different

1.5 hour

Deleting logbook data: about 5 min

for the number

3.5 hour

Deleting old chart: about 15 min

of licensed cell.

Installing chart: about 1 3 hour

(*1)

Ver.00000050

Updating software: about 10min


C-Map Ed.3

About

Deleting Playback data: about 5 min

70 min

Deleting logbook data: about 5 min


Installing chart: about 50 min

(*1) Estimated time for re-installing ENCincluding AVCS charts: about 1 - 3 hours
about 30 minutes per 1 CD (the whole JAPAN)
about 13 hours (the whole world)
about 1 hour per 100 charts that have been permitted

If there are few equipment, estimated time for updating software is necessary by number of equipments.
2

7ZZNA4266A

Estimated installing time


Estimated time for updating software

: about 10 minutes

Estimated time for deleting of current ENC charts

: about 15 minutes

Estimated time for re-installing ENCincluding AVCS charts

: about 13 hours

about 30 minutes per 1 CD (the whole JAPAN)


about 13 hours (the whole world)
about 1 hour per 100 charts(*1) that have been permitted

1. If there are few equipment, estimated time for updating software is necessary by number of equipments.
2. Check estimated time the above even if also using together different type of chats.
Objective model of this manualJAN-701B/901B/2000/1186, NDC-1186-4xx

7ZZNA4266A

1.

Flow chart

The work outline of the software update is described in the following. Confirm it before work by all means.

Start

Step1Creating the software update CD

Start Updating

Step2Confirming of latest Base CD, Update CD, and Cell permit(In case of using ENC)
Step3Confirming latest C-Map database DVD and license (in case of using C-Map)
Step4Confirming of current software version.
Step5Software update
Step6Confirming of software update
Step7Deleting of current ENC(Contain AVCS) charts (In the case of using ENC)
Step8Re-install of ENC(Contain AVCS) charts (In case of using ENC)
Step9Re-installing C-Map database (in case of using C-Map)
Step10Re-installing C-Map license (in case of using C-Map)
Step11Confirming of Navigation & Planning
Step12Storage of Update CD

Step13Sending of software update result

Finish

7ZZNA4266A

Step1Creating the software update CD


Create the software update CD according to following step

Parts list
Parts

Qty

CD-R Media

PC(Windows)

Requirements
CD-R writing software is installed.

1) Extract the V0056_ECDIS_RPS-NWS_R2_0.ZIP file.


2) Open the folder V0056_ECDIS_RPS-NWS_R2_0 and confirm extract files as follows.

File name

Type

after.bat

BAT file

before.bat

BAT file

EUpdate.exe

Update installer

Setup.exe

Application installer

Readme.txt

Text file

CMCL4

Folder

Document

Folder
The 5 files and 2 folder is written
to root directory of CD-R.

3) Burn the 5 files and 2 folder which are confirmed in 2) to CD-R with CD-R writing software.

Dont change file name, otherwise the software is not be installed correctly.

Dont change the directory structure. Otherwise, it could not update


correctly.

7ZZNA4266A

4) Confirm the composition of CD-R. Confirm that each file is written to root directory.
5) Describe to CD as follows (handwriting is possible). Use a oil paint pen.

ECDIS Update CD
JAN-701B/901B/2000/1186
NDC-1186-4xx

Maintenance Ver.56
XXXXXXX 2012

Do not use a ball pens.


Otherwise, software update CD does not work normally.

This is end of creating of update CD.

7ZZNA4266A

Step2Confirming of latest Base CD, Update CD, and Cell permit(In case of
using ENC)
When executing software update and re-installing ENC (Contain AVCS) charts, following items are
required:
Latest Base CD
Latest Update CD

Step3Confirming latest C-Map database DVD and license (in case of using
C-Map)
After updating software, it is necessary to re-install C-Map database. So, following item is necessary at updating..
z

Latest database DVD

Latest license file

7ZZNA4266A

Step4Confirming of current software version.


Confirm current software version according to following step.
1)

Push [POWER] key of objective model.


[POWER] key of JAN-701B/901B is on the left of the control unit.

POWER Key

[POWER] key of JAN-2000/1186 is in front center part of the case.

POWER Key

[POWER] key of NDC-186-4-xx is in front center part of the case.

POWER Key

7ZZNA4266A

2)

After ECDIS software start-up, move the cursor on the Startup" menu, then right-click in the mouse of
the operation unit, and will be displayed the PASSWORD" dialog.

3)

When right-clicking again on the PASSWORD" dialog, "Software keyboard" is displayed. Input the
password "85100" and left-click ENT.
85100

Software keyboard

ENT

Input 85100 and left-click ENT.


Right-click on the
Startup menu.

Right-click on the
PASSWORD menu.
PASSWORD dialog

Startup menu

4)

System Information" dialog is displayed. Software version is described in MaintenanceNo. .


Please Fill in MaintenanceNo. on Version before software updates at "Request for sending of
software update result"

5)

that is the end page of this procedure.

After confirming of software version, left-click [Close].

7ZZNA4266A

Step5Software update
Update software according to below step.
1) Insert Software Update CD into the DVD drive.
For JAN-701B/901B, there is DVD drive when opening the cap in the upper part of front panel.

Open the cap in the upper part of front panel.


(above fig is JAN-701B stand alone
type.There is the cap in the same place for
desktop type, and JAN-901B too.)

DVD drive

For JAN-2000/1186, there is DVD drive in the upper left.

DVD drive

For NDC-1186-4xx, is in front center part of the case.

DVD drive

10

7ZZNA4266A

2) Move the cursor on Startup Menu, and right-click the trackball on operation panel to display
PASSWORD dialog.
3) On PASSWORD dialog, right-click the trackball once again, then Software Keyboard is displayed
and Enter password 5858 and left-click ENT.
5858

Software keyboard

ENT

Input 5858 and left-click ENT.


Right-click on the
Startup menu.

Right-click on the
PASSWORD menu.
PASSWORD dialog

4) Confirm that Software Update: Q:EUpdate.exe is displayed in the upper dialog box, and then
left-click [OK] button.

Software Update path

Attention
If the Software Update CD is not recognized, software data path is not displayed as following.

Left-click [Cancel] button and then confirm that Software Update CD is inserted in to the DVD Drive.

11

7ZZNA4266A

Attention
If following message is displayed, this software is not accepted to update because of special
software. Please contact to JRC service agent.

The message list is following.


1. You can't install as this system is non-standard.
2. This model is not applicable.Confirm the ECDIS model.
3. You can't install as version is incompatible.

5) Following dialog is displayed. Confirm that upgrading version is 56, then left-click [Yes] button.

Confirm that upgrading version is


56.

12

7ZZNA4266A

6) The Caution dialog is displayed. Left-click [Yes] button.

7) The Caution dialog is displayed. Left-click [Yes] button.

13

7ZZNA4266A

8) Update is started. It takes several minutes. You can not select [Close] button until update is finished.

9)

The dialog is displayed as follows. Left-click [OK] button.

10) After update, left click [Close] button.

14

7ZZNA4266A

11) After updating the software "e-Token Setup" dialog is displayed. It is necessary to carry out this
operation even if C-map is used / not used. Left-click [Yes] button.

Select eToken PRO(32K)


In case of selecting eToken PRO(JAVA), it is not possible to update

12) Left-click

eToken PRO(32k) button.

15

7ZZNA4266A

13) e-Token runtime and C-Map SDK runtime are installed

14) After installing start up menu is displayed automatically.

This is the end of updating software If another ECDIS are installed, update other ECDIS

16

7ZZNA4266A

Troulbeshooting

Symptom/Cause/Countermeasure (common)
Symptom

Cause

Countermeasure

Pop-up of " If you have an


eToken" is re-displayed.
By selection of eToken type,
eTokenPro (Java) is chosen and
eToken cannot be recognized.

Message IMPORTANT: Please


insert the eToken now and press
OK to continue

Please choose the direction suitable for


eToken of use on the selection screen of
eToken type.

It is not equipped with eToken.

Please equip with eToken and redo


update operation.

Registration of eToken
information has not been
performed.

Please equip with eToken and redo


update operation.

Since update of C-Map


environment has gone wrong.

Please redo update operation with


reference to "Resumption procedure of
update."

Since update of C-Map


environment has gone wrong.

Please redo update operation with


reference to "Resumption procedure of
update."

A Startup menu is not displayed


but only a blue screen is
displayed.

MessageThis application has


failed to start because
CMGBASE.DLL was not found.
Re-installing the application
may fix this problem.

17

7ZZNA4266A

Resumption procedure of update


(1) Insert update CD in a CD-ROM drive.
(2) Select [Start]button[Run...]menu

(3) Click [Brows] button

(4) Choose EUpdate.exe in CD-ROM. and click [Open] button.

(5) Click [OK] button

18

7ZZNA4266A

Step6Confirming of software update


After update software, confirm that software update according to following step.
1)

Move the cursor on the Startup" menu, then right-click in the mouse of the operation unit, and will be
displayed the PASSWORD" dialog.

2)

When right-clicking again on the PASSWORD" dialog, then "Software keyboard" is displayed. Input
the password "85100 and left-click ENT.
85100

Software keyboard

ENT

Input 85100 and left-click ENT.


Right-click on the
Startup menu.

Right-click on the
PASSWORD menu.
PASSWORD dialog

Startup menu
3)

System Information is displayed. Please confirm that Maintenance No. is 00000056.

4)

Left-click [Close] button after confirming of software version.

This is end of confirming of software update.


Carry out next page

19

7ZZNA4266A

Step7Deleting of current ENC(Contain AVCS) charts (In the case of using


ENC)
1) Start up ECDIS software, then left-click

ChartPortfolio.

Startup menu
2) Select [Sort] [S-57] at Chart port folio window.

3) Select [S-57] System Chart tab and [S57] folder to display the imported S-57charts.
Select [S-57]System Chart
tab
Select [S-57] folder

20

7ZZNA4266A

4) Move cursor to upper left side of Chart displaying. By using track ball, move the cursor to lower right
side with keeping pushing left-click button. Selected charts are highlight (gray / blue) displayed.
Move cursor to upper left side of
Chart displaying.

Selected charts are highlight (gray


/ blue) displayed.
Track ball
Left-click button

5) After selecting all charts, select [Edit] [Delete] at [Chart Portfolio] menu.

6) Left-click [OK] button.

After deleting all charts, folders are deleted. Confirm that all charts are deleted at [S-57] Source Chart and
[S-57] System Chart.

21

7ZZNA4266A

7) Left-click Exit button and finish Chart Portfolio.


8) Move the cursor on the Startup" menu, then right-click in the mouse of the operation unit, and will
be displayed the PASSWORD" dialog.
9) When right-clicking again on the PASSWORD" dialog, then "Software keyboard" is displayed.

Software keyboard

Right-click on the
Startup menu.

Startup menu

Right-click on the
PASSWORD menu.

PASSWOR Ddialog

10) Start Chart Portfolio again


11) Select [Tool] [Technical Tool] [Deleting unlicensed [S-57/S-63] system charts...]

12) Enter [8510] and left-click [OK] button.

8510

13) Left-click [OK] button

22

7ZZNA4266A

Step8Re-install of ENC(Contain AVCS) charts (In case of using ENC)


Please re-install the ENC(Contain AVCS) in accordance with the following procedure.
1) Start Chart Portfolio at Start up menu.
2) Insert ENC/AVCS Chart CD-ROM into the CD/DVD-ROM drive.
3) Select [Sort] [S-63(Offline)] in that order.
S-63 chart list will appear in several minutes.

Select [Sort] - [S-57] in that order when importing S-57 chart.


4) Left-click [Import/Update] button..
The Import Condition dialog box will appear.

S-63 chart list

23

7ZZNA4266A

Attention:
When UPDATE information is included in the BASE CD-ROM(PRIMAR or
UKHO (AVCS ) ), the following dialog box appears. Left-clicked the [OK]
button.

When the [Cancel] button is left-clicked, check a chart display and


accept updating from Navigation&Planning.

Structure, format and validity of the chart are checked.

24

7ZZNA4266A

Left-clicking the [Log] button will show the import result.


[Log] button

[Log] window

Total number of charts to be imported


Number of charts imported

excluding invalid ones.


(Charts updated previously are counted in.)

Progress meter shows the progress of the import processing according to


the capacity of the chart files already processed.

25

7ZZNA4266A

5) Check that the import process is completed, and then, left-click the [Exit] button to exit Chart Portfolio.
Left-click the [Exit] button.

Total number of charts to be imported. exc

26

7ZZNA4266A

Troulbeshooting
If an error message is displayed during the reinstallation ENC(including AVCS) chart, please see the table
below.

1. Symptom/Cause/Countermeasure
Symptom
Message Confirm CD type, and retry
Auto Detect. is displayed in Chart
Portfolio.

Cause

Countermeasure

CD -ROM is not inserted into a


CD/DVD-ROM drive.
Insert Chart CD into a CD/DVD-ROM
drive.
CD/DVD-ROM is not Chart CD.

Message CD is not inserted, or this CD


might have errors. Confirm, or contact
with your chart provider. is displayed in
Chart Portfolio.

Path setting is wrong.

Set the path as the correct position.


Refer to Reference Document 1: Alarm
Information of S-57/S63 Chart.

Message There is no licensed chart.


is displayed in Chart Portfolio.

Importing charts are not covered for


the chart existed in ECDIS.

Check the details of the contract.

Licensed chart is not contained in this


CD-ROM.

Insert licensed CD-ROM into


CD/DVD-ROM drive.

Refer to the attached document


Reference Document 1: Alarm
Information of S-57/S63 Chart.

Refer to the attached document


Reference Document 1: Alarm Information
of S-57/S63 Chart.

displayed in Chart Portfolio.

Different SA Certificate file was


selected.

Select SA Certificate file of the data server


to import.

Message Errors occurred in

Cell permit was not imported.

Error code error0x000000xxis


displayed in log window of Chart
Portfolio.

Message Warning SA public key


supplied on the ENC media unmatches
the pre-installed SA public key. is

Decryption! Refer the log to check the


detail is displayed in Chart

Portfolio.

Cell permit was deleted.

License was expired.

27

Import the correct cell permit.

7ZZNA4266A

Symptom

Cause

MessageWarning:SSE 10 - Permits not


available for this data provider. is
displayed in Chart Portfolio.

Data server ID written in serial.enc


that is included in CD is different from
Data server ID written in Cell Permit.

Use the correct CD or Import the correct


Cell Permit

There are some Cell Permit that will


expire within 30 days.

Regist the latest Cell permits.

Expired Cell permits are remaindered.

Register the latest Cell permit after


deleting Cell permit. See 2.7 Deleting
Cell Permit (Only S-63).

Selected SA is Certificate supplied


from the Non-IHO.

That is no problem in chart importing.

MessageWarning:SSE 20 Subscription service will expire in less


than 30 days. Please contact your data
supplier to renew the subscription
licence. is displayed in Chart Portfolio.
Even if the latest Cell permit is
registered, Warning:SSE 15 Subscription service has expired.
Please contact your data supplier to
renew the subscription licence.
message is appeared.
Message Warning:SSE 26 - This ENC
is not authenticated by the IHO acting as
the Scheme Administrator. is displayed
in Chart Portfolio.

28

Countermeasure

7ZZNA4266A

Step9Re-installing C-Map database (in case of using C-Map)


Re-installing C-map database is need. Re-install the C-map database as follows.
1) Start ECDIS software, and left-click

C-Map Chart Manager.Chart Manager

Startup menu
2) Insert the C-Map database DVD-Rom into the DVD drive.
3) Left-click [Search automatically] at the Databases tab.

29

7ZZNA4266A

4) Select the DVD drive (Q), and left-click [Search] button.

5) Select searched database by left-clicking, and left-click [Register database] button.

6) Following message is displayed, left-click [Yes] button.

30

7ZZNA4266A

7) Select the path of database as follows, and left-click [OK] button.


D:/ECDIS_DATA/c933
When D drive can not be selected, select the path as follows.
E:/ECDIS_DATA/c933

Wait a few seconds until database saves into HDD


.

31

7ZZNA4266A

8) Confirm that database is saved, and left-click [Close] button.

9) In case that licensing database DVD is more two, carry out from 1) to 8) each database.

This is the end of re-installing C-Map database.

32

7ZZNA4266A

Step10Re-installing C-Map license (in case of using C-Map)


Re-installing C-map license is need. Re-install the C-map license as follows.

Attention
C-Map Dynamic Licensing service is need other licensing procedure.
So please see the Chart installation manual.

1) Start Chart Manager.


2) Select the installing database at Licenses tab. And left-click [Import from file].

3) Select the license filepassword.usr, left-click [Open] button.

33

7ZZNA4266A

4) If importing license is succeeding, the following message is displayed. So, left-click [OK] button.

5) Confirm that license is imported, left-click [Close] button.

6) In case that licensing database DVD is more two, carry out from 1) to 5) each database.
This is the end of re-installing C-map license.

34

7ZZNA4266A

Step11Confirming of Navigation & Planning


1)

Left click Startup menu in

button and start Navigation & Planning.

2) Confirming Navigation & Planning start normally and GPS,Gyro,Log sensor input.

35

7ZZNA4266A

Step12Storage of Update CD
Software update CD may be reused.
Please keep software update CD on the ship importantly after the software update is completed.
z

Please put this manual and software update CD in a clear file on the back side of the front cover for
JAN-701B/901B. It is possible to open the front cover by loosening the screws of the four corners.

Please put this manual and upgrade CD in a clear file on the back side of the front cover.

The equipments for JAN-2000/1186NDC-1186-4xx have no storage area in the system, please
keep this manual and software update CD importantly on the ship.

This is the end of the storage of the software update CD.

Step13Sending of software update result


Fill in necessary matters on "Request for sending of software update result" in the end of the manual, and
send a e-mail or a fax to JRC Marine service department (TMSC).
FAX

03-3779-1420 (+81-3-3779-1420)

E-mail

ecdis-disp@jrc.co.jp

This is the end of the software updating of Ver.00000056.

36

7ZZNA4266A

Reference Document 1: Alarm Information of S-57/S63 Chart


This section explains the details of the alarm information that may appear inside the log window of Chart
Portfolio while S-57/S-63 chart is imported/updated on ECDIS.

When Base CD is used:


No.

Error message

Cause

Countermeasure

The chart defined in the


error(0x00000001)
catalogue file in Chart CD
error:File not found
is missing.

error(0x00000002)
error:File Length

Data length of the catalog


file in Chart CD is
abnormal.

error(0x00000003)
error:File
extension

File extension of Chart CD


is abnormality.

error(0x00000004)
error:File count 0

There is not chart file in


Chart CD.

error(0x00000005)
error:Data not
found

There is not specification


data.

error(0x00000006)
error:Data error

File data structure of Chart


CD is abnormal.

error(0x00000007)
error:CRC

CRC value of the chart file


in Chart CD is abnormal.

error(0x00000008)
error:Exchange

Interchange data in Chart


CD is abnormal.

error(0x00000009)
error: Data
structure

File structure in Chart CD


is abnormal.

10

Attribute value of the


error(0x0000000A) objects defined in the chart
file of Chart CD is
error:Attribute
abnormal.

Clean the CD-ROM, and then, perform import


procedure again.

37

If the error persists, contact the distributor of


the chart for the measures to take.
It is a fatal error for Chart CD. Neither import
nor update is possible for this Chart CD.

7ZZNA4266A

When Base CD is used - continued:


No.

Error message

Cause

Countermeasure

error(0x0000000B)
error:Instruction
Address
error(0x0000000C)
error:Instruction
offset
error(0x0000000D)
error:PL Rule
Memory
error(0x0000000E)
error:PL Rule
Information

Internal memory address


(instruction section) is
abnormal.
Internal memory offset
(instruction section) is
abnormal.

15

error(0x0000000F)
error:Attribute
Information

Acquisition of attribute
data of chart object is
faulty.

Contact the retailer of the chart for the


measures to take.

16

error(0x00000010)
error:Enc File write

Writing of SENC file is


faulty.

Refering to the Instruction Manual, check the


free space in the HDD.
Contact the retailer of the chart for the
measures to take.

17

error(0x00000011)
error:Object Class
get

Acquisition of chart object


information is faulty.

18

error(0x00000012)
error: Directory
create

File path is abnormal.

19

error(0x00000013)
error:Topology

Topology of the chart


object in Chart CD is
abnormal.

20

error(0x00000014)
error:Area Object
Link

Link of chart area object


in Chart CD is abnormal.

21

error(0x00000015)
error: Line Object
Link

If the error persists, contact the distributor of


Link of line object in Chart the chart for the measures to take.
It is a fatal error for Chart CD. Neither import
CD is abnormal.
nor update is possible for this Chart CD.

22

error(0x00000016)
error: Object
outside range

Chart object in Chart CD


is out of boundary.

11
12
13
14

Contact the retailer of the chart for the


measures to take.

Memory allocation is
faulty (PL rule section).
Data acquisition is faulty
(PL rule section).

Contact the retailer of the chart for the


measures to take.

38

Clean the CD-ROM, and then, perform import


procedure again.

7ZZNA4266A

When Update CD is used:


No.

Error message

Cause

Countermeasure

error(0x00000001)
error:Memory get

Memory allocation is
faulty

error(0x00000002)
error:Index get

Acquisition of chart index


is faulty.

error(0x00000003)
SENC file is missing.
error:File not found

error(0x00000004)
error:CRC

CRC value of chart file in


Chart CD is abnormal.

error(0x00000005)
error:Exchange

Interchange data of
Update CD is abnormal.

Contact the retailer of the chart for the


measures to take.
Reproduction of index is required. It may take
several hours.
Contact the retailer of the chart for the
measures to take.

Clean the CD-ROM, and then, perform import


procedure again.

error(0x00000006)
error:Data
structure

error(0x00000007)
error:Data not
found

error(0x00000008)
error:Object not
found

Chart object name of


SENC is missing.

error(0x00000009)
error:Chart Cell
size

Acquisition of chart file size


of SENC is faulty.

10

error(0x0000000A)
error:Chart Cell
data

Acquisition of chart file of


SENC is faulty.

11

error(0x0000000B)
error:Warning Cell
size

Acquisition of warning file


size of
SENC is faulty.

12

error(0x0000000C)
Acquisition of warning file
error:Warning Cell
of SENC is faulty.
data

File structure of Update CD


is abnormal.
If the error persists, contact the distributor of
the chart for the measures to take.It is a fatal
Chart defined in the
error for Update CD. This chart cannot be
catalogue file of Update
updated.
CD is missing.

39

Contact the retailer of the chart for the


measures to take.

7ZZNA4266A

When Update CD is used - continued:


No.

Error message

Cause

Countermeasure

13

error(0x0000000D) Sequence of update


number of Update CD is
error:Sequential
abnormal.
number error

14

error(0x0000000E)
error:Object index

Object index of update


chart in Update CD is
abnormal.

15

error(0x0000000F)
error:Attribute
information

Attribute information of
update chart in Update CD
is abnormal.

16

error(0x00000010)
error:Attribute

Attribute value of update


chart in
Update CD is abnormal.

17

error(0x00000011)
error:Instruction
Address

Internal memory address


(instruction section) is
abnormal.

18

error(0x00000012)
error:Instruction
Offset

Internal memory offset


(instruction section) is
abnormal.

19

error(0x00000013)
error:PL Rule
Memory

Memory allocation is
faulty (PL rule section).

20

error(0x00000014)
error:PL Rule
Information

Data acquisition is faulty


(PL rule section).

Clean the CD-ROM, and then, perform import


procedure again.
If the error persists, contact the distributor of
the chart for the measures to take.It is a fatal
error for Update CD. This chart cannot be
updated.

Contact the retailer of the chart for the


measures to take.

Remove the system chart that occured error


once, and then, perform import procedure
again.
If the error persists, Contact the retailer of the
chart for the measures to take.

21

error(0x00000015)
error:Enc File write

Writing of SENC file is


faulty.

22

error(0x00000016)
error:Object Class
get

Acquisition of chart object Contact the retailer of the chart for the
information is faulty.
measures to take.

40

7ZZNA4266A

When Update CD is used - continued:


No.

Error message

Cause

23

error(0x00000017)
error:Data
structure

Data structure of Update


CD is abnormal.

24

error(0x00000018)
error:FFPC delete

25

error(0x00000019)
error:FFPC edit

26

error(0x0000001A)
error:FSPC delete

27

error(0x0000001B)
error:FSPC edit

28

Data structure of Update


error(0x0000001C)
CD (deletion of VRPC
error:VRPC delete
field) is abnormal.

29

Data structure of Update


error(0x0000001D)
CD (modification of VRPC
error:VRPC edit
field) is abnormal.

30

error(0x0000001E)
error:SGCC delete

Data structure of Update


CD (deletion of SGCC
field) is abnormal.

31

error(0x0000001F)
error:SGCC edit

Data structure of Update


CD (modification of
SGCC field) is abnormal.

32

error(0x00000020)
error:Coordinate
Type

Data structure of Update


CD (coordinate type) is
abnormal.

33

error(0x00000021)
error:Directory
create

File path is abnormal.

Countermeasure

Data structure of Update


CD (deletion of FFPC
field) is abnormal.
Data structure of Update
CD (modification of FFPC
field) is abnormal.
Data structure of Update
CD (deletion of FSPC
field) is abnormal.
Data structure of Update
CD (modification of FSPC Clean the CD-ROM, and then, perform import
procedure again.
field) is abnormal.
If the error persists, contact the distributor of
the chart for the measures to take.It is a fatal
error for Update CD. This chart cannot be
updated.

Contact the retailer of the chart for the


measures to take.

41

7ZZNA4266A

When Update CD is used - continued:


No.

Error message

Cause

34

Topology of chart object


error(0x00000022)
in Update CD is
error:Topology
abnormal.

35

Link of chart area object


error(0x00000023)
in Update CD is
Area Object Link
abnormal.

36

37
38

39

Countermeasure
Clean the CD-ROM, and then, perform import
procedure again.
If the error persists, contact the distributor of
the chart for the measures to take.
It is a fatal error for Update CD. This chart
cannot be updated.

error(0x00000024)
Link of chart line object in
error:Line Object
Update CD is abnormal.
Link

error(0x00000025)
error:Object
outside range
error(0x00000026)
error:point

Chart object of Update


CD is out of boundary.

Clean the CD-ROM, and then, perform import


procedure again.
If the error persists, contact the distributor of
the chart for the measures to take.It is not a
fatal error for Update CD.
Clean the CD-ROM, and then, perform import
procedure again.

Chart point object of


Update CD is abnormal.

If the error persists, contact the distributor of


the chart for the measures to take.It is a fatal
error for Update CD. This chart cannot be
updated.

error(0x00000027)
Edition number of Chart
error:Edition
CD is abnormal.
number

42

7ZZNA4266A

Request for sending of software update result


Please fill in the update result on the following tables and send it to our company after software upgrading
and reinstalling the chart is completed. Please submit one piece a model.
Addressee

Marine Service Department(TMSC)

FAX

03-3779-1420 (+81-3-3779-1420)

E-mail

ecdis-disp@jrc.co.jp
Please apply the sign
Equipment model

JAN-701B

JAN-901B

to the equipment used.


JAN-2000

JAN-1186

NDC-1186-4xx
Serial number
Ships name
The name of customer
The contact information of
customer
Version before software
updates
Version after software
updates
Storage area of software
update CD
Please apply the sign
Use chart

ENC(Contain AVSC)
Others(

to the chart used.


ARCS

C-MAP Ed.3

Please apply the sign


All chart deletion

of the deletion existing chart.


No deletion

Fill in the reason when you cannot delete all charts.


There is no Base CD
There is no Update CD

Reinstallation of chart

There is no Cell Permit


Other(Fill in the reason)

Please apply the sign


finished
Date

of chart reinstalling.

not finished
(Month)

Name/Signature
Branch office/branch/agency

43

(Day),

(Year)

Das könnte Ihnen auch gefallen