Beruflich Dokumente
Kultur Dokumente
JAN-701B/901B/2000/1186NDC-1186-4xx
ECDIS/RPS/NWS
Software Update Manual for
Ver.00000056(V56)
in case that the current version is 00000050(V50)
Contents
z
Outline ...................................................................................................................................................1
1.
7ZZNA4266A
z Outline
This is an update manual of Ver.00000056 from Ver.00000050 software for JAN-701B/901B/2000/1186,
NDC-1186-4xx.
In case of using ENC, Before update, confirm that there are latest Base CD and
Update CD.
7ZZNA4266A
Remark
Software update CD
Download the files from TSMC or Amsterdam branch website and create the
software update CD according to Step:1
ENC/AVCS
Data base CD
ENC/AVCS
Cell Permit CD
C-Map Ed.3
Database DVD
C-Map Ed.3
License file
Chart
ENC
(including AVCS)
Working
breakdown
time
Remark
Chart installing
About
time is different
1.5 hour
3.5 hour
of licensed cell.
(*1)
Ver.00000050
About
70 min
(*1) Estimated time for re-installing ENCincluding AVCS charts: about 1 - 3 hours
about 30 minutes per 1 CD (the whole JAPAN)
about 13 hours (the whole world)
about 1 hour per 100 charts that have been permitted
If there are few equipment, estimated time for updating software is necessary by number of equipments.
2
7ZZNA4266A
: about 10 minutes
: about 15 minutes
: about 13 hours
1. If there are few equipment, estimated time for updating software is necessary by number of equipments.
2. Check estimated time the above even if also using together different type of chats.
Objective model of this manualJAN-701B/901B/2000/1186, NDC-1186-4xx
7ZZNA4266A
1.
Flow chart
The work outline of the software update is described in the following. Confirm it before work by all means.
Start
Start Updating
Step2Confirming of latest Base CD, Update CD, and Cell permit(In case of using ENC)
Step3Confirming latest C-Map database DVD and license (in case of using C-Map)
Step4Confirming of current software version.
Step5Software update
Step6Confirming of software update
Step7Deleting of current ENC(Contain AVCS) charts (In the case of using ENC)
Step8Re-install of ENC(Contain AVCS) charts (In case of using ENC)
Step9Re-installing C-Map database (in case of using C-Map)
Step10Re-installing C-Map license (in case of using C-Map)
Step11Confirming of Navigation & Planning
Step12Storage of Update CD
Finish
7ZZNA4266A
Parts list
Parts
Qty
CD-R Media
PC(Windows)
Requirements
CD-R writing software is installed.
File name
Type
after.bat
BAT file
before.bat
BAT file
EUpdate.exe
Update installer
Setup.exe
Application installer
Readme.txt
Text file
CMCL4
Folder
Document
Folder
The 5 files and 2 folder is written
to root directory of CD-R.
3) Burn the 5 files and 2 folder which are confirmed in 2) to CD-R with CD-R writing software.
Dont change file name, otherwise the software is not be installed correctly.
7ZZNA4266A
4) Confirm the composition of CD-R. Confirm that each file is written to root directory.
5) Describe to CD as follows (handwriting is possible). Use a oil paint pen.
ECDIS Update CD
JAN-701B/901B/2000/1186
NDC-1186-4xx
Maintenance Ver.56
XXXXXXX 2012
7ZZNA4266A
Step2Confirming of latest Base CD, Update CD, and Cell permit(In case of
using ENC)
When executing software update and re-installing ENC (Contain AVCS) charts, following items are
required:
Latest Base CD
Latest Update CD
Step3Confirming latest C-Map database DVD and license (in case of using
C-Map)
After updating software, it is necessary to re-install C-Map database. So, following item is necessary at updating..
z
7ZZNA4266A
POWER Key
POWER Key
POWER Key
7ZZNA4266A
2)
After ECDIS software start-up, move the cursor on the Startup" menu, then right-click in the mouse of
the operation unit, and will be displayed the PASSWORD" dialog.
3)
When right-clicking again on the PASSWORD" dialog, "Software keyboard" is displayed. Input the
password "85100" and left-click ENT.
85100
Software keyboard
ENT
Right-click on the
PASSWORD menu.
PASSWORD dialog
Startup menu
4)
5)
7ZZNA4266A
Step5Software update
Update software according to below step.
1) Insert Software Update CD into the DVD drive.
For JAN-701B/901B, there is DVD drive when opening the cap in the upper part of front panel.
DVD drive
DVD drive
DVD drive
10
7ZZNA4266A
2) Move the cursor on Startup Menu, and right-click the trackball on operation panel to display
PASSWORD dialog.
3) On PASSWORD dialog, right-click the trackball once again, then Software Keyboard is displayed
and Enter password 5858 and left-click ENT.
5858
Software keyboard
ENT
Right-click on the
PASSWORD menu.
PASSWORD dialog
4) Confirm that Software Update: Q:EUpdate.exe is displayed in the upper dialog box, and then
left-click [OK] button.
Attention
If the Software Update CD is not recognized, software data path is not displayed as following.
Left-click [Cancel] button and then confirm that Software Update CD is inserted in to the DVD Drive.
11
7ZZNA4266A
Attention
If following message is displayed, this software is not accepted to update because of special
software. Please contact to JRC service agent.
5) Following dialog is displayed. Confirm that upgrading version is 56, then left-click [Yes] button.
12
7ZZNA4266A
13
7ZZNA4266A
8) Update is started. It takes several minutes. You can not select [Close] button until update is finished.
9)
14
7ZZNA4266A
11) After updating the software "e-Token Setup" dialog is displayed. It is necessary to carry out this
operation even if C-map is used / not used. Left-click [Yes] button.
12) Left-click
15
7ZZNA4266A
This is the end of updating software If another ECDIS are installed, update other ECDIS
16
7ZZNA4266A
Troulbeshooting
Symptom/Cause/Countermeasure (common)
Symptom
Cause
Countermeasure
Registration of eToken
information has not been
performed.
17
7ZZNA4266A
18
7ZZNA4266A
Move the cursor on the Startup" menu, then right-click in the mouse of the operation unit, and will be
displayed the PASSWORD" dialog.
2)
When right-clicking again on the PASSWORD" dialog, then "Software keyboard" is displayed. Input
the password "85100 and left-click ENT.
85100
Software keyboard
ENT
Right-click on the
PASSWORD menu.
PASSWORD dialog
Startup menu
3)
4)
19
7ZZNA4266A
ChartPortfolio.
Startup menu
2) Select [Sort] [S-57] at Chart port folio window.
3) Select [S-57] System Chart tab and [S57] folder to display the imported S-57charts.
Select [S-57]System Chart
tab
Select [S-57] folder
20
7ZZNA4266A
4) Move cursor to upper left side of Chart displaying. By using track ball, move the cursor to lower right
side with keeping pushing left-click button. Selected charts are highlight (gray / blue) displayed.
Move cursor to upper left side of
Chart displaying.
5) After selecting all charts, select [Edit] [Delete] at [Chart Portfolio] menu.
After deleting all charts, folders are deleted. Confirm that all charts are deleted at [S-57] Source Chart and
[S-57] System Chart.
21
7ZZNA4266A
Software keyboard
Right-click on the
Startup menu.
Startup menu
Right-click on the
PASSWORD menu.
PASSWOR Ddialog
8510
22
7ZZNA4266A
23
7ZZNA4266A
Attention:
When UPDATE information is included in the BASE CD-ROM(PRIMAR or
UKHO (AVCS ) ), the following dialog box appears. Left-clicked the [OK]
button.
24
7ZZNA4266A
[Log] window
25
7ZZNA4266A
5) Check that the import process is completed, and then, left-click the [Exit] button to exit Chart Portfolio.
Left-click the [Exit] button.
26
7ZZNA4266A
Troulbeshooting
If an error message is displayed during the reinstallation ENC(including AVCS) chart, please see the table
below.
1. Symptom/Cause/Countermeasure
Symptom
Message Confirm CD type, and retry
Auto Detect. is displayed in Chart
Portfolio.
Cause
Countermeasure
Portfolio.
27
7ZZNA4266A
Symptom
Cause
28
Countermeasure
7ZZNA4266A
Startup menu
2) Insert the C-Map database DVD-Rom into the DVD drive.
3) Left-click [Search automatically] at the Databases tab.
29
7ZZNA4266A
30
7ZZNA4266A
31
7ZZNA4266A
9) In case that licensing database DVD is more two, carry out from 1) to 8) each database.
32
7ZZNA4266A
Attention
C-Map Dynamic Licensing service is need other licensing procedure.
So please see the Chart installation manual.
33
7ZZNA4266A
4) If importing license is succeeding, the following message is displayed. So, left-click [OK] button.
6) In case that licensing database DVD is more two, carry out from 1) to 5) each database.
This is the end of re-installing C-map license.
34
7ZZNA4266A
2) Confirming Navigation & Planning start normally and GPS,Gyro,Log sensor input.
35
7ZZNA4266A
Step12Storage of Update CD
Software update CD may be reused.
Please keep software update CD on the ship importantly after the software update is completed.
z
Please put this manual and software update CD in a clear file on the back side of the front cover for
JAN-701B/901B. It is possible to open the front cover by loosening the screws of the four corners.
Please put this manual and upgrade CD in a clear file on the back side of the front cover.
The equipments for JAN-2000/1186NDC-1186-4xx have no storage area in the system, please
keep this manual and software update CD importantly on the ship.
03-3779-1420 (+81-3-3779-1420)
ecdis-disp@jrc.co.jp
36
7ZZNA4266A
Error message
Cause
Countermeasure
error(0x00000002)
error:File Length
error(0x00000003)
error:File
extension
error(0x00000004)
error:File count 0
error(0x00000005)
error:Data not
found
error(0x00000006)
error:Data error
error(0x00000007)
error:CRC
error(0x00000008)
error:Exchange
error(0x00000009)
error: Data
structure
10
37
7ZZNA4266A
Error message
Cause
Countermeasure
error(0x0000000B)
error:Instruction
Address
error(0x0000000C)
error:Instruction
offset
error(0x0000000D)
error:PL Rule
Memory
error(0x0000000E)
error:PL Rule
Information
15
error(0x0000000F)
error:Attribute
Information
Acquisition of attribute
data of chart object is
faulty.
16
error(0x00000010)
error:Enc File write
17
error(0x00000011)
error:Object Class
get
18
error(0x00000012)
error: Directory
create
19
error(0x00000013)
error:Topology
20
error(0x00000014)
error:Area Object
Link
21
error(0x00000015)
error: Line Object
Link
22
error(0x00000016)
error: Object
outside range
11
12
13
14
Memory allocation is
faulty (PL rule section).
Data acquisition is faulty
(PL rule section).
38
7ZZNA4266A
Error message
Cause
Countermeasure
error(0x00000001)
error:Memory get
Memory allocation is
faulty
error(0x00000002)
error:Index get
error(0x00000003)
SENC file is missing.
error:File not found
error(0x00000004)
error:CRC
error(0x00000005)
error:Exchange
Interchange data of
Update CD is abnormal.
error(0x00000006)
error:Data
structure
error(0x00000007)
error:Data not
found
error(0x00000008)
error:Object not
found
error(0x00000009)
error:Chart Cell
size
10
error(0x0000000A)
error:Chart Cell
data
11
error(0x0000000B)
error:Warning Cell
size
12
error(0x0000000C)
Acquisition of warning file
error:Warning Cell
of SENC is faulty.
data
39
7ZZNA4266A
Error message
Cause
Countermeasure
13
14
error(0x0000000E)
error:Object index
15
error(0x0000000F)
error:Attribute
information
Attribute information of
update chart in Update CD
is abnormal.
16
error(0x00000010)
error:Attribute
17
error(0x00000011)
error:Instruction
Address
18
error(0x00000012)
error:Instruction
Offset
19
error(0x00000013)
error:PL Rule
Memory
Memory allocation is
faulty (PL rule section).
20
error(0x00000014)
error:PL Rule
Information
21
error(0x00000015)
error:Enc File write
22
error(0x00000016)
error:Object Class
get
Acquisition of chart object Contact the retailer of the chart for the
information is faulty.
measures to take.
40
7ZZNA4266A
Error message
Cause
23
error(0x00000017)
error:Data
structure
24
error(0x00000018)
error:FFPC delete
25
error(0x00000019)
error:FFPC edit
26
error(0x0000001A)
error:FSPC delete
27
error(0x0000001B)
error:FSPC edit
28
29
30
error(0x0000001E)
error:SGCC delete
31
error(0x0000001F)
error:SGCC edit
32
error(0x00000020)
error:Coordinate
Type
33
error(0x00000021)
error:Directory
create
Countermeasure
41
7ZZNA4266A
Error message
Cause
34
35
36
37
38
39
Countermeasure
Clean the CD-ROM, and then, perform import
procedure again.
If the error persists, contact the distributor of
the chart for the measures to take.
It is a fatal error for Update CD. This chart
cannot be updated.
error(0x00000024)
Link of chart line object in
error:Line Object
Update CD is abnormal.
Link
error(0x00000025)
error:Object
outside range
error(0x00000026)
error:point
error(0x00000027)
Edition number of Chart
error:Edition
CD is abnormal.
number
42
7ZZNA4266A
FAX
03-3779-1420 (+81-3-3779-1420)
ecdis-disp@jrc.co.jp
Please apply the sign
Equipment model
JAN-701B
JAN-901B
JAN-1186
NDC-1186-4xx
Serial number
Ships name
The name of customer
The contact information of
customer
Version before software
updates
Version after software
updates
Storage area of software
update CD
Please apply the sign
Use chart
ENC(Contain AVSC)
Others(
C-MAP Ed.3
Reinstallation of chart
of chart reinstalling.
not finished
(Month)
Name/Signature
Branch office/branch/agency
43
(Day),
(Year)