Sie sind auf Seite 1von 92

Dewatering pump handbook

Dewatering
pump handbook
Rental, sales and service for construction,
mining, municipal and other industries.

The handbook i an essential working tool for


pump operators, supervisor, site managers
and engineers, who work with pumps on a
daily basis.
Here you will find an overview of all Flygt and
Godwin dewatering pumps and accessories,
including technical details such as
performance curves, sizes, dimensions and
weights. Our comprehensive range covers
virtually every size. Pressure, flow rate and
functionality.
Whether you want to buy you can depend on
us for reliable equipment, service and turnkey
solutions for any dewatering application in
more than 140 countries.

Contents
Page
Industries and applications
Flygt submersible drainage pumps
* 2600 series
* 2600 sludge series
* 2000 series
* 2700 series
* Ready series

4
6-33
6
14
18
28
32

Flygt slurry pumps


* 5000 series

34-41
34

Accessories for Flygt submersibles

42-45

Godwin pumps
Automatic self-priming pumps
* Dri-Prime CD series
* Dri-Prime HL series
* Electric drive and sound attenuation availability
* Wellpoint series

46-75
46-63
47
54
60
62

Hydraulic submersible pumps


64-75
* Heidra HS series
65
* Heidra Hs slurry gate/vortexx/vortex slurry gate series
69
* Heidra HS high head series
74
Accessories for Godwin pumps

76-77

Pumps 101

78-87

Monitoring & control

88

Spare parts & service

89

Industries and applications

Mining and quarring

Oil and gas

Industrial

Open pit and underground drainage


Face and stage
dewatering
Slurry tailings removal
process water supply

Product transfer in
refineries
Pipeline pigging
Process water supply

Pumping industrial
wastewater
Fly ash removal
Temporary fire pumps

Construction
and tunneling

Municipal

Site drainage and


wellpoint dewatering
Bentonite slurry
pumping
Stream diversions
Drill ring water supply

Emergency drainage of
flood waters
Sewage bypass
Lift station backup
pumping
Sludge removal

Marine
Barge ballasting
Vessel dewatering
Jetting

Nobody does dewatering


better
No matter what the challenge, our dewatering
solutions keep you on solid ground.
Rental
Rent dewatring pumps, equipment and accessories
on on a daily, weekly, monthly or project basis.
Sales
Buy dewatering pumps, equipment and
accessories.
Service
Use our global service network that spans 140
countries to support you with application
engineering, pump repair, spare parts and turnkey
project management.

Flygt submersible drainage pumps

2600 series
Flygt 2600 pumps are engineered for
professional use in tough dewatering
applications in mines, construction,
tunneling and industrial sites. Extreme
durability and wear-resistance make
these pumps deliver highly consistent
performance over long periods of time.
Three times more wear-ressistant than
conventional, drainage pumps, Flygt
2600 pumps feature our patented
DuraSpin hydraulic system, fewer
components, durable materials and
ergonomic design.

Flygt
submersible
drainage
pumps
Flygt submersible
drainage
pumps
2600 series

2610.171
20

15

H (m)

K 237 MT
K 234 MT

10

K 243 MT

0
0

2
10

20
Q

10

30

12
40

I/s
m3/h

K = Clog-resistant impeller.

Model
Rating [kW]
Voltage [V/phase]
Rated current [A]
Weight [kg]
Max. height [mm]
Max. width [mm]
Discharge [in]
Strainer hole [mm]
Warm liquid, 70oC

K 243 MT
0.85
230.1
5.1
19
570
195
2
7.5
Yes

K 234 MT
1.2
400,3
2.7
21
594
195
2
7.5
Yes

K 237 MT
1.4
230.1
7.8
21
594
195
2
7.5
Yes

For additional specifications, see product technical documentation.


With reservation for changes.

2600 series

2620.171
25
20

B 226 MT

H (m)

15
10

B 233 MT
B 234 MT

5
0

0
0

10

20

10
30

40

15
50

20
60

I/s

3
70 m /h

Q
B = Wear-resistant impeller. K= Clog-resistant impeller.

Model
Rating (kW)
Voltage (V/phase)
Rated current(A)
Weight(kg)
Max height(mm)
Max width(mm)
Discharge @ (in)
Stainer hole (mm)
Warm liquid,70oc

B 226 MT
2.2
400,3
4.7
30
617
240
3
7.5
Yes

K 233 MT
1.5
230.1
8.4
28
617
240
3
7.5
Yes

K 234 MT
2.2
400,3
4.7
28
617
240
3
7.5
Yes

For additional specifications, see product technical documentation.


With reservation for changes.

Flygt
submersible
drainage
pumps
Flygt submersible
drainage
pumps
2600 series

2630.180
40

B 251 HT

30

H (m)

20
B 226 MT
K 234 MT

10

10

0
0

20

40

20
60

30
80

40

I/s
3

100 120 140 m /h

Q
B = Wear-resistant impeller. K = Clog-resistant impeller.

Model
Rating [kW]
Voltage [V/phase]
Rated current [A]
Weight [kg]
Max. Height [mm]
Max. width [mm]
Discharge [in]
Strainer hole [mm]
Warm liquid, 70oC

B 226 MT
3.7
400,3 ~
7.3
49
759
286
4''
10
Yes

B 251HT
3.7
400,3 ~
7.3
49
759
286
3''
10
Yes

K 234 MT
3.7
400,3 ~
7.3
49
759
286
4''
10
Yes

For additional specifications, see product technical documentation.


With reservation for changes.

10

2600 series

2640.180
50
B 251 HT

40

H (m)

30
20

B 226 MT

10
K 234 MT

10

20

30

60

120

40

50

I/s
3

180 m /h

Q
B = Wear-resistant impeller. K = Clog -resistant impeller.

Model
Rating [kW]
Voltage [V/phase]
Rated current [A]
Weight [kg]
Max. height [mm]
Max. width [mm]
Discharge [in]
Strainer hole [mm]
Warm liquid, 70oC

B226 MT
5.6
400,3 ~
11
51
759
286
4
10
Yes

B251 HT
5.6
400,3 ~
11
51
759
286
3
10
Yes

K 234 MT
5.6
400,3 ~
11
51
759
286
4
10
Yes

For additional specifications, see product technical documentation.


With reservation for changes.

11

Flygt
submersible
drainage
pumps
Flygt submersible
drainage
pumps
2600 series

2660.180
100
80

B 251 HT

H (m)

60

40

B 226 MT
K 234 MT

20
0

10

20

50

30

40

100

150

50

60
200

70

I/s

3
250 m /h

Q
B = Wear-resistant impeller. K = Clog-resistant impeller.

Model
Rating [kW]
Voitage [V/phase]
Rated current [A]
Weight [kg]
Max. Height [mm]
Max. width [mm]
Discharge [in]
Strainer hole [mm]
Warm liquid, 70oC

B 226 MT
10
400,3 ~
19
78
803
345
6
10
Yes

B 251HT
10
400,3 ~
19
78
803
345
4
10
Yes

B 276 SH
10
400,3 ~
19
96
890
345
4
10
Yes

K234 MT
10
400,3 ~
19
78
803
345
6
10
Yes

Available with Flygt Soft starter to reduce starting current. See page 43.
For additional specifications, see product technical documentation.
With reservation for changes.

12

2600 series

2670.180
70
60
B 251 HT

50

H (m)

40
30
20
B 226 MT

10
0

0
0

20
50

40
100

60

80

100

I/s

3
150 200 250 300 350 m /h
Q

B = Wear-resistant impeller.

Model
Rating [kW]
Voltage [V/phase]
Rated current [A]
Weight [kg]
Max. height [mm]
Max. width [mm]
Discharge [in]
Strainer hole [mm]
Warm liquid, 70oC

B226 MT
18
400,3 ~
32
140
955
395
6
12
Yes

B251 HT
18
400,3 ~
32
140
955
395
4
12
Yes

For additional specifications, see product technical documentation.


With reservation for changes.

13

Flygt
submersible
drainage
pumps
Flygt submersible
drainage
pumps

2600 sludge
series
Built on the Flygt 2600
series platform, these
portable sludge pumps
tackle the tough challenge
of moving sludge and
other liquid with ease
without clogging.
These compact solids handling pumps feature a
high chrome vortex
impeller to enable the
passage of large solids as
well as solids
concentrations of
approximately 20% by
weight.
This makes them ideal for
dewatering in construction,
mining, industrial and
wastewater applications.

14

2600 sludge series

2620.281
20

H (m)

15

D 2620.281 MT 1 ~

10

5
D 2620.281 MT 3 ~

0
0

2
10

20

10

30

12
40

14

I/s

3
50 m /h

Q
D = Solids-handling impeller.

Model
Rating [kW]
Voltage [V/phase]
Rated current [A]
Weight [kg]
Max. height [mm]
Max. width [mm]
Discharge [in]
Strainer hole [mm]
Warm liquid, 70oC

MT, 1-ph
1.5
230,1 ~
8.4
34
730
375
3
50
No

MT, 3-ph
1.5
400,3 ~
4.7
34
730
330
3
50
No

For additional specifications, see product technical documentation.


With reservation for changes.

15

Flygt
submersible
drainage
pumps
Flygt submersible
drainage
pumps
2600 sludge series

2630.280
10
D 2630.280 MT

H (m)

6
4
2
0

20

10

15

40

20
60

25
80

I/s
m3/h

Q
D = Solids-handling impeller.

Model
Rating [kW]
Voltage [V/phase]
Rated current [A]
Weight [kg]
Max. height [mm]
Max. width [mm]
Discharge [in]
Strainer hole [mm]
Warm liquid, 70oC

MT, 3-ph
3.2
400,3 ~
7.3
54
865
480
4
80
No

For additional specifications, see product technical documentation.


With reservation for changes.

16

2600 sludge series

2640.280
40
35
D 2640.280 HT

30
25
H (m)

20
15
10
D 2640.280 MT

5
0

0
0

10

5
10

20

30

40

15
50

20
60

I/s

3
70 m /h

Q
D = Solids-handling impeller.

Model
Rating [kW]
Voltage [V/phase]
Rated current [A]
Weight [kg]
Max. height [mm]
Max. width [mm]
Discharge [in]
Strainer hole [mm]
Warm liquid, 70oC

MT, 1-ph
5.6
400,3 ~
11
56
865
480
3
46
No

MT, 3-ph
5.6
400,3 ~
11
56
865
480
3
32
No

For additional specifications, see product technical documentation.


With reservation for changes.

17

Flygt
submersible
drainage
pumps
Flygt submersible
drainage
pumps

2000 series
Flygt 2000 pumps easily handle chemically
aggressive, mechanically abrasive or highly
viscous fluids laden with particles. They handle
higher flow rates up to 300 l/s and heads up to
200 meters.
Flygt 2000 products are available in lightweight
aluminum or corrosion-resistant cast iron. Some
models are available in explosion-proof Ex
versions.

18

19

Flygt
submersible
drainage
pumps
Flygt submersible
drainage
pumps
2000 series

2071.010
40
B 231 MT

30

H (m)

20
B 211 LT

10

0
0

10

6
20

8
30
Q

10
40

12

14
50

16

I/s

3
58 m /h

D = Solids-handling impeller.

Model
Rating [kW]
Voltage [V/phase]
Rated current [A]
Weight [kg]
Max. height [mm]
Max. width [mm]
Discharge [in]
Strainer hole [mm]
Warm liquid, 70oC

MT, 1-ph
5.6
400,3 ~
11
56
865
480
3
46
No

MT, 3-ph
5.6
400,3 ~
11
56
865
480
3
32
No

For additional specifications, see product technical documentation.


With reservation for changes.

20

2000 series

2075.324 (Cast iron)


100
80
B 271 ST (Ex versions)

H (m)

60
40
B 233 HT

20
B 231 MT

0
0

Modal
Rating [kW]
Voltage [V/phase]
Rated current [A]
Weight [kg]
Max. height [mm]
Max. width [mm]
Discharge [in]
Strainer hole [mm]
Warm liquid, 70oC

5
20

B 231 MT
3.7
400,3 ~
7.1
40
570
310
4"
6x26
Yes

10
40
Q

15

20
60

B 233 HT
3.7
400,3 ~
7.1
40
570
310
3"
6x26
Yes

I/s

25
80

m3/h

B 271 ST
5.5
400,3 ~
11
69
650
310
4"
6x6
Yes

Available in Ex versions 2075.590/690


For additional specifications, see product technical documentation.
With reservation for changes.

21

Flygt
submersible
drainage
pumps
Flygt submersible
drainage
pumps
2000 series

2075.320 (Cast iron)


80

H (m)

60

40

B 233 HT

20

B 231 MT

0
0

Model
Rating [kW]
Voltage [V/phase]
Rated current [A]
Weight [kg]
Max. height [mm]
Max. width [mm]
Discharge [in]
Strainer hole [mm]
Warm liquid, 70oC

10
50

B 231 MT
8
400,3 ~
15
77
830
485
4"
6x50
No

20

30
100
Q

40
150

50
200

60

I/s
m3/h

B 233 HT
8
400,3 ~
15
80
865
465
3"
6x50
No

Available in Ex versions 2125.690


For additional specifications, see product technical documentation.
With reservation for changes.

22

2000 series

2125.181
80
70
B 233 HT

60
50
H (m)

40
30
B 234 HT

20
10
0

0
0

10

5
10

20

30

40

15
50

20
60

I/s

3
70 m /h

Model
Rating [kW]
Voltage [V/phase]
Rated current [A]
Weight [kg]
Max. height [mm]
Max. width [mm]
Discharge [in]
Strainer hole [mm]
Warm liquid,70oC

B 233 HT
8
400
15
80
830
465
3"
6x50
No

B 234 HT
8
400
15
80
830
465
3"
6x50
No

For additional specifications, see product technical documentation.


With reservation for changes.

23

Flygt
submersible
drainage
pumps
Flygt submersible
drainage
pumps
2600 series

2201.011
MT
LT

100
80

B 251 HT

H (m)

60

HT

40
B 231 MT

20
B 411 LT

50

100

150

200

250

I/s
3

0 100 200 300 400 500 600 700 800 900 m /h


Q

Model
Rating [kW]
Voltage [V/phase]
Rated current [A]
Weight [kg]
Max. height [mm]
Max. width [mm]
Discharge [in]
Strainer hole [mm]
Warm liquid, 70oC

B 411 LT
30
400,3 ~
57
280
1302
500
8"
15x45
No

B 231 MT
37
400,3 ~
65
280
1302
500
8"
15x45
No

B 243 HT
37
400,3 ~
65
240
1050
430
4"
10x10
No

For additional specifications, see product technical documentation.


With reservation for changes.

24

2000 series

2201.320 (Cast iron)


40
B 231 MT

30

H (m)

20
B 211 LT

10

0
0

Model
Rating [kW]
Voltage [V/phase]
Rated current [A]
Weight [kg]
Max. height [mm]
Max. width [mm]
Discharge [in]
Strainer hole [mm]
Warm liquid,70oC

10

B 231 MT
37
400,3 ~
65
445
1140
500
8"
15x45
Yes

6
20

8
30
Q

10

12

40

14
50

16

I/s

3
58 m /h

B 233 HT
37
400,3 ~
65
350
1050
435
4"
10x10
Yes

Available in Ex versions 2201.590/690


For additional specifications, see product technical documentation.
With reservation for changes.

25

Flygt
submersible
drainage
pumps
Flygt submersible
drainage
pumps
2000 series

2250.11
40
B 231 MT

30

H (m)

20
B 211 LT

10

0
0

Model
Rating [kW]
Voltage [V/phase]
Rated current [A]
Weight [kg]
Max. height [mm]
Max. width [mm]
Discharge [in]
Strainer hole [mm]
Warm liquid,70oC

10

B 431 MT
54
400,3 ~
104
540
1260
940
10"
15x45
No

6
20

8
30
Q

10
40

12

14
50

16

I/s

3
58 m /h

B 433 HT
54
400,3 ~
104
540
1260
838
6"
15x45
No

For additional specifications, see product technical documentation.


With reservation for changes.

26

2000 series

2400.402
40
B 231 MT

30

H (m)

20
B 211 LT

10

0
0

Model
Rating [kW]
Voltage [V/phase]
Rated current [A]
Weight [kg]
Max. height [mm]
Max. width [mm]
Discharge [in]
Strainer hole [mm]
Warm liquid,70oC

10

6
20

8
30
Q

B 231 MT
90
400,3 ~
148
900
1180
770
6"
10x10
No

10
40

12

14
50

16

I/s

3
58 m /h

B 243 HT
90
400,3 ~
148
985
1245
770
4"
10x10
No

Available in Ex versions 2201.590/690


For additional specifications, see product technical documentation.
With reservation for changes.

27

Flygt
submersible
drainage
pumps
Flygt submersible
drainage
pumps

2700 stainless steel


series
The all-stainless steel Flygt 2700 series handles
corrosive and abrasive liquids with wide variances in
pH levels. These pumps are built to tackle the
toughest dewatering challenges.
The Flygt 2700 series consists of three drainage
pumps to handle lightly contaminated liquids and
three solids handling pumps, deals for pH values
between 2 and 10, these pumps are tough enough to
handle both highly acidic and highly alkaline media.

28

29

Flygt
submersible
drainage
pumps
Flygt submersible
drainage
pumps
2700 series

2720, 2740, 2750


70
60
B 266 HT (2750)

50
B 266 HT (2740)

40
H (m)

B 241 MT (2740)

30
B 241 MT (2750)

20

B 241 MT (2720)

10
0

10

20
50

30
100
Q

40

50

150

60
200

I/s
m3/h

B = Wear-handling impeller.

Model
Rating [kW]
Voltage [V/phase]
Rated current [A]
Weight [kg]
Max. hight [mm]
Max. width [mm]
Discharge [in]
Strainer hole [mm]
Warm liquid, 70oc
pH

B 2720
2.0
400,3 ~
4.4
44
600
235
3''
25x7
No
2-10

B 2740
6.0
400,3 ~
12
75
725
280
3''/4''
25x7
No
2-10

B2750
8.0
400 ~
15
90
780
280
3"/4"
25x7
No
2-10

For additional specifications, see product technical documentation.


With reservation for changes.

30

2700 sludge series

2720, 2730, 2740


25
20
D 243 HT (2740)

15
H (m)

D 241 MT (2720)

10
D 241 MT (2730)

5
0

10

30

20

25

60
Q

30

I/s

35

3
120 m /h

90

D = Solids-handling impeller.

Modal
Rating [kW]
Voltage [V /phase]
Rated current [A]
Weight [kg]
Max. height [mm]
Max. width [mm]
Discharge [in]
Throughlet [mm]
Warm liquid, 70oC
pH

D 2720
2.0
400,3 ~
4.4
48
715
420
3
50
No
2-10

D 27830
4.1
400,3 ~
8.8
95
845
440
3/4
75/80
No
2-10

D 2740
6.3
400,3 ~
12
95
845
440
3/4
46
No
2-10

For additional specifications, see product technical documentation.


With reservation for changes.

31

Flygt
submersible
drainage
pumps
Flygt submersible
drainage
pumps

Ready series
Compact, lightweight and easy to carry,
the Flygt Ready series delivers high
performance for their size. These
small drainage pumps are capable
of handling liquids with pH levels
3-9.
Impact-resistant from the
inside out, these portable
submersible pumps
combine abrasion and
corrosion-resistance
with economical and
long-lasting pumping
power.

32

Ready series

2004, 2008
14
B 2008

12
10
8
H (m)

D 2008

6
B 2004

4
2
0

2
5

10

15

6
20

I/s

25 m3/h

Q
B = Wear-resistant impeller. D = Solids-handling impeller.

Modal
Rating [kW]
Voltage [V/phase]
Rated current [A]
Weight [kg]
Max. height [mm]
Max. width [mm]
Discharge [in]
Strainer hole [mm]
Warm liquid, 70oC

B 2004
0.4
230,1 ~
2.7
10
400
185
2"
11.5
No

B 2008
0.75
230,1 ~
4.2
12.5
433
185
2"
11.5
No

D 2008
0.9
230,1 ~
5.2
15
510
230
2"
38
No

For additional specifications, see product technical documentation.


With reservation for changes.

33

Flygt
submersible
drainage
pumps
Flygt submersible
drainage
pumps

5000 series

Rugged, reliable and cost effective, the


Flygt 5000 series of submersible slurry
pumps handle transportation of the
most abrasive solids that are suspended
in liquid.
Designed for excellent performance, low
energy consumption, long wear life and
easy maintenance, our Flygt 5000 series
pumps serve a wide range of slurry
transport applications.
With a slim, compact design, these
abrasive and corrosive-resistant portable
slurry pumps provide quiet, economical
solutions for slurry transportation.

34

35

Flygt
slurry pumps
Flygt submersible
drainage pumps
5000 series

H 5100
40

20

B
10

Modal
Rating [kW]
R. current [A]
Weight [kg]
Max. height [mm]
Max. width [mm]
Discharge [in]
Strainer hole [mm]
Warm liquid, 70oC
Agitator
Ex version

C
D

211
7.5-13.5
9.4-28
215
978
547
4"
30
Yes
Yes
221

10

20

251
15-22
17-41
277
1124
547
4"
30
Yes
Yes
261

30
40
Q / I/s

300
22-45
25-82
585
1296
595
4"
30
Yes
Yes
310

Performance

H (m)

30

50

60

A
B
C
D

211
430
432
630
632

70

80

251
430
432
630
632

(400 = 4 pole, 600 = 6 pole)


E.g. 5100.21153-430

Internal and external cooling available


For additional specifications, see product technical documentation.
With reservation for changes.

36

300
430
432
630
632

5000 series

H 5150
60
50

H (m)

40

A
B

30

C
D

20

10

Model
Rating [kW]
Rated current [A]
Weight [kg]
Max. height [mm]
Max. width [mm]
Discharge [in]
Strainer hole [mm]
Warm liquid, 70oC
Agitator
Ex version

300
30-45
32-82
585
1410
875
4"
36
Yes
Yes
310

25

50

75 100 125 150


Q (I/s)

350
50-70
59-132
817
1537
875
6"
36
Yes
Yes
360

300
Performance

A
B
C
D
E

430
432
434

175 200

350
430
432
434
436
438

E.g. 5150.350 53-436

Internal and external cooling available


For additional specifications, see product technical documentation.
With reservation for changes.

37

Flygt
slurry pumps
Flygt submersible
drainage pumps
5000 series

H 5520, 5530
20

H (m)

15

10

A
B
C

5
D

Model
Ratint [kW]
Rated current [A]
Weight [kg]
Max. height [mm]
Max. width [mm]
Discharge [in]
Strainer hole [mm]
Warm liquid,70oC
Agitator
Ex version

5520
3.1
6.3
122
848
478
4"
20
Yes
No
Yes

10

20

5530
5.9
7-12
203
848
632
6"
30
Yes
Yes
Yes

30
40
Q (I/s)

50

60

70

300
Performance

A
B
C
D

80

350
434
436

436
438

E.g 5530.181 53-436

External cooling available


For additional specifications, see product technical documentation.
With reservation for changes.

38

5000 series

H 5570
100

H (m)

80

60
H 5570*

40

20

50

100

150 200
Q (I/s)

250

300

350

* Consult pump selection program for details on performance.

Model
Rating [kW]
Rated current [A]
Weight [kg]
Max. height [mm]
Max. width [mm]
Discharge [in]
Strainer hole [mm]
Warm liquid, 70oc
Agitator
Ex version

5570 600 drive


58-105
118-200
1190-1350
1675-2068
983-1225
8
30
No
No
Yes

5570 700 drive


100-215
202-395
1700-2000
1829-2312
983-1225
8
30
No
Yes
Yes

External cooling available


For additional specifications, see product technical documentation.
With reservation for changes.

39

Flygt
slurry pumps
Flygt submersible
drainage pumps

Calculation effects of slurry


1. Determine SG/density of the liquid. If the density is
unknown, it can be determined by using the formula or
nomograph;
Cw/Cv = S/Sm

S = Specific gravity (SG) of dry solids


Sm = SG of the slurry
Cv = Concentration of solids by volume
Cw = Concentration of solids by weight

Max Cv for centrifugal pumps is 40%


2. Calculate the critical velocity. Choose a pipe diameter so
that the pipe velocity is higher than the critical velocity.
1. Water + coarse gravel 4 m/s
2. Water gravel 3 m/s
3. Water + sand
Particles < 0.1 mm 1.5 m/s
Particles < 0.6 mm 2.5 m/s
(Pipe velocity V=Q/A [A=prpe area])
Use diagram or formula in
Chapter engineering. If the
concentration is more than
15% by volume (Cv) , the value
should be adjusted using the
correction factor (Cf)
diagram. Cf for slurry Cv = 30%
= 1.5

40

Solids by volume, Cv

3. Calculate the total discharge head.


40
30
20
10
1.0

1.2

1.5

Construction factor, Cf

1.8

4. The required duty point has now been established


(Htotal). If the solid concentration exceeds i15% by volume,
the discharge head of the pump must be reduced. By
dividing the duty head with the reduction factor (HR) the
equivalent clean-water pump head is obtained (Hcv).
Head Reduction
C
HR = 1 - K x v
20
30
= 1 - 0.04 x
20
Htotal
Hcv =
HR

Example S = 1.8. D85 = 1 mm K = 0.04

Htotal = Head total slurry


Hfrsl = Friction losses for
slurry
Hfrcw = Friction losses
Clean Water
Hfrsl = Hfrcw x Cf
Htotal = Hstat + Hfrsl

5. The pump can now be selected based on the flow and


head values above.
6. The power curves for the pumps are based on cIean
water and these must then be multiplied by the specific
gravity of the slurry to obtain the corresponding value for
slurry pumping. Flygt recommends a motor with a 20%
excess power margin for slurry applications due to
variations slurry.

41

Accessories
Flygtpumps
submersibles
Flygt
submersiblefor
drainage

Accessories

42

Hoses, cables and starters


Complement our extensive range of Flygt submersible
drainage pumps with a wide range of accessories that
simplify installation and operation.

Flygt Softstarter

Discharge outlet types

Reduces starting current


to smooth motor
acceleration and protect
the pump.

Enables convenient attachment of a hose or connection


for vertical and horizontal pumping.

Discharge hoses

Flygt SUBCAB

Meets your requirements


through a wide variety of
sizes.

Ensures electricity supply and supervision reliability


through built-in monitoring cores in submersible power
cables.

43

Accessories
for
Flygtpumps
submersibles
Flygt submersible
drainage

Mechanical accessories
Adapt your pump to your specific requirements using
our broad range of mechanical accessories.

Flygt pump raft

Flygt zinc anode kits

Keeps pump afloat using


lightweight glass-fiber
reinforced polymer.

Provides extra protection


against galvanic corrosion
for all metal parts.

Flygt tandem
connection
Connects two or more
pumps in series for extra
high head operation.

44

Flygt low suction collar


Removes unwanted water
down to very low levels
when required for
emergency services.

Electrical accessories
Automate pump operations with Flygt electrical accessories
and reduce energy costs as well as pump wear.

Flygt FPC100 pump


controller
Automatically controls the
pump without the use of
level sensors.

Flygt external level


controller

Flygt level regulators


Controls pump starts and
stops based on actual
water levels and/or
activates an alarm device.

Flygt pump mounted Flygt pump starters (manual and automatic)


Provides thermal / magnetic overload protection,
level regulator
thermal contact supervision sequence indication.

45

Godwin
automatic
self-priming
pumps
Flygt submersible
drainage
pumps

46

Dir-Prime CD series

CD75, CD80D
20

(2000 rpm)

60
CD80D

50

15

30
20

H (ft)

H (m)

40
CD75

10

10
0

0
0

10

Model
Engine
Max. Solids handling [mm]
Suction @ [mm]
Discharge @ n[mm]
Max. operating speed [rmp]

20

10
30

40
Q

15
50

CD75
Yanmar L100 AE
40
50
50
2000

20
60

I/s

m3/h

CD80D
Kubote Z482
40
80
80
2000

Min. running time at max. speed 4 h

52 h

Fuel tank capacity [l]


Dry run capacity
Consumed power [kW]

72
Yes
4.5

5
Yes
4.5

70

Dimensions L x W x H [mm]

1100x652x800

1300x680x1900

Weight [kg]

150

569

For additional specifications, see product technical documentation.


With reservation for changes.

47

Godwin
automatic
self-priming
pumps
Flygt submersible
drainage
pumps
Dri-Prime CD series

CD100M, CD103M
(1800 rpm)

120

35
CD103M

100

30
25

80

H (m)

CD100M

20

60

15
40

H (ft)

40

10
20

5
0

0
0

10

20

50

30
100
Q

40
150

50

60
200

I/s

m3/h

Model

CD100M

CD103M

Engine

Perkins 403D-15

Perkins 404D-22

Max. solids handling [mm]


Suction @ [mm]
Discharge @ [mm]
Max. operating speed [rpm]

45
100
100
1800

75
100
100
1800

Min. running time at max. speed 22 h

26 h

Fuel tank capacity [l]


Dry run capacity
Consumed power [kW]

170
Yes
23

72
Yes
11

Dimensions LxWxH [mm]

1300x680x1900

1800x1000x1900

Weight [kg]

1050

1128

For additional specifications, see product technical documentation.


With reservation for changes.

48

Dri-Prime CD series

CD150M, CD225M
50

(2000 rpm)

150

40

125

CD225M

H (m)

75

(1500 rpm)

20

CD150M

50

10
0

H (ft)

100

30

25
50

0
0

100

150

200

100 200 300 400 500 600 700


Q

Model

CD150M

CD225M

Engine

Perkins 404D-22

Perkins
1104D-E44TA

Max. solids handling [mm]


Suction @ [mm]
Discharge @ [mm]
Max. operating speed [rpm]

65
150
150
1500

75
200
200
2000

Min. running time at max. speed 38 h

17 h

Fuel tank capacity [l]


Dry run capacity
Consumed power [kW]

390
Yes
74.1

170
Yes
16

I/s

m3/h

DimensionsLxWxH[mm]

1800x1000x1900

2500x1300x1900

Weight [kg]

1345

2255

For additional specifications, see product technical documentation.


With reservation for changes.

49

Godwin
automatic
self-priming
pumps
Flygt submersible
drainage
pumps
Dri-Prime CD series

CD250M, DPC300
50

160

(2000 rpm)

140

40

CD250M

120

H (m)

(1020 rpm)*

80
DPC300

20

60

H (ft)

100

30

40

10

20
0

50

200

100

150

400

600
Q

200

250

800

300

1000

Model

CD250M

Engine

Perkins1104D-E44TA Perkins
1104D-E44TA

Max. solids handling [mm]


Suction @ [mm]
Discharge @ [mm]
Max. operating speed [rpm]

75
250
250
2000

DPC300

95
300
300
1020

Min. running time at max. speed 17 h

38 h

Fuel tank capacity [l]


Dry run capacity
Consumed power [kW]

850
Yes
74.1

390
Yes
72

I/s

m3/h

DimensionsLxWxH[mm]

2500x1300x1900

3700x1700x2200

Weight [kg]

2433

4201

For additional specifications, see product technical documentation.


With reservation for changes.

50

Dri-Prime CD series

CD300M, CD400M
50

160

(1500 rpm)

140

40

CD300M

120

H (m)

80

(1000 rpm)*

20

60

CD400M

H (ft)

100

30

40

10

20
0

0
0

100

200

500

300
1000
Q

400

500

1500

600

2000

I/s

m3/h

*Curve references pump speed, engine speed will be greater


through use of gear box

Model

CD300M

CD400M

Engine

Perkins 1106D
-E66TA (129)

Perkins 1106D
-E66TA (168)

Max. solids handling [mm]


Suction @ [mm]
Discharge @ [mm]
Max. operating speed [rpm]

95
300
300
1500

125
450
400
1000

Min. running time at max. speed 28 h

17 h

Fuel tank capacity [l]


Dry run capacity
Consumed power [kW]

685
Yes
109

850
Yes
94.5

DimensionsLxWxH [mm]

3700x1700x2200

4000x1950x2220

Weight [kg]

5168

7250

For additional specifications, see product technical documentation.


With reservation for changes.

51

Godwin
automatic
self-priming
pumps
Flygt submersible
drainage
pumps
Dri-Prime CD series

CD500M
70

(1100 rpm)*

60

200

CD500M

50
150
100

30

H (ft)

H (m)

40

20
50
10
0

0
0

200
1000

400

600
2000
Q

800

1000

3000

I/s
m3/h

*Curve references pump speed will be greater through use of


gear box

Model
Engine
Maximum solids handling [mm]
Suction @ [mm]
Discharge @ [mm]
Maximum operating speed [rpm]
Minimum running time at maximum speed
Fuel tank capacity [l]
Dry run capacity
Consumed power [kW]
Dimensions L x W x H [mm]
Weight [kg]

CD500M
Caterpillar C18
80
500/600
450
1100
9h
1131
Yes
420
5400x2670x2500
11750

For additional specifications, see product technical documentation.


With reservation for changes.

52

Dri Prime CD Series (Elevated head, solids handling)

CD140M, CD160M, CD180M


(2000 rpm)

300

80

250

CD180M

H (m)

60

200

(1800 rpm)

150
40

CD140M

CD160M

100
20
0

H (ft)

100

50
0

200

400

100

200

600
300

800

1000

400

I/s

3
500 m /h

Model

CD140M

Engine

Perkins 1104D Perkins 1104D Perkins 1106D


-44TA
-E44TA
E66TA (129)

Max. solids [mm]


75
Suction @ [mm]
100
Discharge @ [mm] 100
Max. op. speed [rpm]1800
Min. running time
19 h
Fuel t. capacity [l]
390
Dry run capacity
Yes
Con. power [kW]
57

CD160M

75
150
150
1800
17 h
390
Yes
71.9

CD180M

75
200
150
2000
13 h
475
Yes
106.7

Dim. L x W x H [mm]

2500x1300x1900 2500x1300x1900 2950x1300x1900

Weight [kg]

2131

2425

2758

For additional specifications, see product technical documentation.


With reservation for changes.

53

Godwin
automatic
self-priming
pumps
Flygt submersible
drainage
pumps
Dri-Prime HL Series

HL80M, Hl100M, HL125M


100

(2000 rpm)

300

HL125M

80

(1800 rpm)

250

H (m)

HL80M

150

40
100
20
0

H (ft)

200

60

50
0
0

10
50

20

30

40

100

50

150
Q

60

200

70

0
80

250

I/s
m3/h

Model

CD140M

CD160M

Engine

Perkins
404D-22T

Perkins
Perkins
1104D-44TA 1104D-E44TA

CD180M

Max. solids [mm]


Suction @ [mm]
Discharge @ [mm]

25
100
80

35
100
100

35
150
100

Max. op. speed [rpm] 2000

1800

2000

Min. running time


Fuel t. capacity [l]
Dry run capacity
Con. power [kW]

23 h
390
Yes
54

15 h
390
Yes
74.1

17 h
170
Yes
29

Dim. L x W x H [mm]

1800x1000x1900 2500x1300x1900 2500x1300x1900

Weight [kg]

1245

2152

2233

For additional specifications, see product technical documentation.


With reservation for changes.

54

Dri-Prime HL series

HL150M, HL200M
120

(2100 rpm)

350

100

300
80
60

200

(1800 rpm)

150

40
HL150M

100

20
0

250
H (ft)

H (m)

HL200M

50
0

25

50

100 200

0
75 100 125 150 175 200 I/s
300 400
Q

3
500 600 700 m /h

Model

HL150M

HL200M

Engine

Perkins
1104D-E44TA

Caterpillar C9

Max. solids handling [mm]


Suction @ [mm]
Discharge @ [mm]
Max. operating speed [rpm]

35
150
150
1800
Min. running time at max. speed 13 h
Fuel tank capacity [l]
390
Dry run capacity
Yes
Consumed power [kW]
71.9

38
200
150
2100
10 h
850
Yes
191

DimensionsLxWxH[mm]

2500x1300x1900

3700x1700x2200

Weight [kg]

2333

4750

For additional specifications, see product technical documentation.


With reservation for changes.

55

Godwin
automatic
self-priming
pumps
Flygt submersible
drainage
pumps
Dir-Prime HL series

HL225M, HL250M
140

450

(2000 rpm)

400

120

HL250M

350

(1800 rpm)

300

H (m)

80

250

HL225M

200

60

150

40

H (ft)

100

100
20
0

50
0

50

200

Model
Engine
Max. solids handling [mm]
Suction @ [mm]
Discharge @ [mm]
Max. operating speed [rpm]

100
400

150 200 250 300


600
Q

HL225M
Caterpillar C9
65
250
200
1800

I/s

3
800 1000 1200 m /h

HL250M
Caterpillar C15
65
300
250
2000

Min. running time at max. speed 13 h

7h

Fuel tank capacity [l]


Dry run capacity
Consumed power [kW]

685
Yes
310

850
Yes
203

0
350

Dimensions L xW x H [mm]

3700x1700x2200

4000x1950x2220

Weight [kg]

5231

6332

For additional specifications, see product technical documentation.


With reservation for changes.

56

Dri-Prime HL series (Extreme high head)

HL260M
175

(1800 rpm)

500

150
125

400

HL260M

300

75
200

H (ft)

H (m)

100

50
100

25
0

0
0

50 100 150 200 250 300 350


250

500

750
Q

Model
Engine
Max.solids handling [mm]
Suction @ [mm]
Discharge @ [mm]
Max. operating speed [rpm]
Min. running time at max. speed
Fuel tank capacity [l]
Dry run capacity
Consumed power [kW]
Dimensions L x W x H [mm]
Weight [kg]

1000

1250

I/s
m3/h

HL260M
Capterpillar C18
50
250
200
1800
5h
685
Yes
425
4300x1980x2525
6900

For additional specifications, see product technical documentation.


With reservation for changes.

57

Godwin
automatic
self-priming
pumps
Flygt submersible
drainage
pumps
Dri-prime HL series (Extreme high head)

HL110M, HL130M, HL160M


200

(2000 rpm)

500

175

400

150
125

400

H (m)

HL130M

HL160M

300

75

200

50

100

25
0

H (ft)

HL110M

100

0
0

20
100

40

60
200

80
300
Q

400

500

I/s
m3/h

Model

CD140M

Engine

Perkins 1104D Caterpillar C9 Caterpillar C15


-E44TA

Max. solids [mm]


20
Suction [mm]
100
Discharge [mm] 80
Max. op. speed [rpm]2000
Min. running time
15 h
Fuel t. capacity [l]
390
Dry run capacity
Yes
Power [kW]
74.1

CD160M

100 120 140

22
150
100
2000
13 h
850
Yes
205

CD180M

35
200
150
2000
7h
685
Yes
303

Dim. L x W x H [mm]

2500x1300x1900 3700x1700x2200 4000x1950x2220

Weight [kg]

2600

5331

6440

For additional specifications, see product technical documentation.


With reservation for changes.

58

59

Godwin
automatic
self-priming
pumps
Flygt submersible
drainage
pumps
Electric drive availability

HL Series

CD Series

Electric drive Godwin Dri-prime pumps are ideal for


use when line power is readily available or when
refueling can be difficult. Electric Dri-Prime pumps are
available with soft starts and variable frequency drives.
Pump
Model

Max.
Motor Voltage
Rated
[kW]
[V/phase] current[A] RPM

CD75
CD80D
CD100M
CD103M
CD140M
CD150M
CD160M
CD180M
CD225M
CD250M
CD300M
CD300
CD400M
CD500M
HL80M
HL100M
HL110M
HL125M
HL130M
HL150M
HL160M
HL200M
HL225M
HL250M
HL260M

15
15
30
45
75
75
110
110
110
110
160
110
200
475
75
110
110
160
200
160
315
170
280
325
550

400V, 3 ~
400V, 3 ~
400V, 3 ~
400V, 3 ~
400V, 3 ~
400V, 3 ~
400V, 3 ~
400V, 3 ~
400V, 3 ~
400V, 3 ~
400V, 3 ~
400V, 3 ~
400V, 3 ~
400V, 3 ~
400V, 3 ~
400V, 3 ~
400V, 3 ~
400V, 3 ~
400V, 3 ~
400V, 3 ~
400V, 3 ~
400V, 3 ~
400V, 3 ~
400V, 3 ~
400V, 3 ~

29
29
54
80
130
130
190
190
190
190
275
190
341
830
130
190
190
275
341
275
529
310
462
575
1050

2900
2900
2000
2200
2000
2200
2000
2000
2200
2200
1800
1200
1200
1100
2400
2200
2200
2400
2000
2400
2000
2000
2000
2000
1800

Dimensions,
LxWxH[mm]

Weight
[kg]

1300x500x800
1400x570x1000
1800x650x1000
2000x650x1050
2350X780X1050
2350X780X1050
2700X1100X1300
2700X1100X1300
2700X1100X1300
2700X1100X1300
3200X1600X1550
3100X1500X1500
4200X2100X1750
4200X2450X2000
2100X680X1140
2200X1050X1295
2300X1050X1270
2595X1115X1270
2800X1250X1300
2750X1240X1400
3100X1300X1500
2790X1300X1400
3000X1300X1450
3100X1300X1500
3200X1350X1600

195
390
475
780
1350
1300
1940
1950
2000
2050
3510
3100
4950
7100
1250
1800
2200
2200
3825
2250
4350
3950
4150
4525
5300

Note : The maximum speeds listed are achieved with a gearbox mounted
on the motor flange or by use of a variable frequency (VFD) control.

60

Sound attenuation availability


Available for all pump models, Godwin soundattenuated enclosures are perfect for use in residential
and other areas to dampen the sound of diesel engine
pumps.

61

Godwin
automatic
self-priming
pumps
Flygt submersible
drainage
pumps

Wellpoint series
Godwin Wellpoint pumps provide excellent groundwater
control for dewatering building site excavations and other
construction operations.
With a design based on the industry standard Dri-Prime
pump, our Wellpoint pumps after convenient automatic
self-priming and indefinite dry running capabilities that
contractors rely on.

62

Wellpoint CD series

CD 100MV, CD150MV, CD225MV


50

160

(2000 rpm)

140

40

120
100
(1500 rpm)
CD225MV

20

60
40

10

20

CD150MV
CD 100MV

80

H (ft)

H (m)

30

0
75 100 125 150 175 200

25

100 200 300 400 500


Q

50

600

I/s

3
700 m /h

Model

CD100MV

CD150MV CD225MV

Engine

Perkins
403D-15

Perkins
404D-22

Perkins
1104D-E44TA

45
150
150

65
200
200

Max. solids handling [mm]


Suction [mm]
100
Discharge [mm] 100
Max. op. speed [rpm] 1500

1500

2000

Min.runningtimeatmax.speed 25 h

38 h

17 h

Fuel tank capacity [l] 72


Dry run capacity
Yes
Power [kW]
11

170
Yes
16

390
Yes
74.1

75

Dim. L x W x H [mm]

1300x680x1900

1800x1000x1900 2500x1300x1900

Weight [kg]

1200

1645

2758

For additional specifications, see product technical documentation.


With reservation for changes.

63

Godwin
hydraulic
submersible
pumps
Flygt submersible
drainage
pumps

Heidra pumps
Self-contained Heidra pumps are reliable hydraulic
submersible pumpends with diesel - or electric driven
power packs for general pumping of light I slurries and
municipal sludges.
Choose from our standard high-volume, vortex, slurry gate
mixer or high head versions.
All models are available trailer-mounted for safe on
highway transportation, in stainless steel for high and low
pH applications, and/or in sound-attenuated enclosures to
dampen noise.

64

Heidra series

HS80, HS100TD, HS103


60

(2200 rpm)

175

50

150
125
HS103

30

100

(2000 rpm)

H (ft)

H (m)

40

75

20

50
10
0

HS100TD

HS80

0
0

10
50

20

30

40

100

150
Q

50

60
200

70

25
0
80

250

Model

HS80

HS100

HS103

EEngine

Kubota 482

Perkins
403D-15
45

Perkins
404D-22T
75

Max. solids handling [mm] 40

Discharge @ [mm]

100

100

Max.operatingspeed[rpm] 2000
Min.runtime @ max.speed 56 h

75

2000
18 h

2200
27 h

Fuel tank capacity [l] 72


Dry run capacity
Yes

72
Yes

170
Yes

Consumed Power [kW] 4

14

38

I/s
m3/h

Powerpack L x W x H [mm] 1300x680x1900 1300x680x1900 1800x1000x1900

Pumpend L x W x H [mm]400x354x558 485x420x581 500x514x647


Weight Pumpend [kg] 70
95
130
Weight Powerpack [kg] 810
945
1136
For additional specifications, see product technical documentation.
With reservation for changes.

65

Godwin
hydraulic
submersible
pumps
Flygt submersible
drainage
pumps
Heidra series

Hs150, HS150MR
50

160

(2000 rpm)

140

40
HS150MR

80
20

60

Hs150

H (ft)

H (m)

120
100

30

40

10

20
0

0
0

20

40

100

60

80

200

300

100 120
400

I/s
3

500 m /h

Model

HS150

HS150MR

Engine

Perkins
403D-22

Perkins
1104D-44T

Max. solids handling [mm]


Disharge [mm]
Max. operating speed [rpm]
Min. runtime @ max. Speed
Fuel tank capacity [l]
Dry run capacity
Consumed power [kW]

65
150
2000
36 h
170
Yes
15

65
150
2000
51 h
390
Yes
41

PowerpackL x W x H [mm]

1800x520x570

2500x1300x1900

Pumpend L x W x H [mm]
Weight pumpend [kg]
Weight powerpack [kg]

680x520x570
152
1052

680x520x570
142
2250

For additional specifications, see product technical documentation.


With reservation for changes.

66

Heidra series

Hs200, HS250
70
200

60
(2100 rpm)

50

150
(2000 rpm)

30

HS250

100

H (ft)

H (m)

40

20

50

HS200

10
0

50

200

100

150

400
Q

600

0
250

200
800

I/s
m3/h

Model

HS200

HS250

Engine

Parkins
1104D-E44TA

Perkins
1106D-E66TA

Max. solids handling [mm]


Discharge [mm]
Max. operating speed [rpm]
Min. runtime @ max. speed
Fuel tank capacity [l]
Dry run capacity
Consumed power [kW]

75
200
2000
17 h
390
Yes
61

75
200
2100
26 h
850
Yes
78

Powerpack L x Wx H [mm]

2500x1300x1900

2950x1300x1900

Pumpend L x W x H [mm]
Weight pumped [kg]
Weight powerpack [kg]

755x721x1250
354
2250

765x740x1200
362
2598

For additional specifications, see product technical documentation.


With reservation for changes.

67

Godwin
hydraulic
submersible
pumps
Flygt submersible
drainage
pumps
Heidra series

Hs300
70

(1800 rpm)

200

60
50

150
100

30

HS300

H (ft)

H (m)

40

20
50
10
0

0
0

100

200

500

300
1000

400
1500

I/s
m3/h

Model
Engine
Max. solids handling [mm]
Discharge [mm]
Max. operating speed [rpm]
Min. runtime @ max. speed
Fuel tank capacity [l]
Dry run capacity
Consumed power [kW]
Powerpack L x W x H [mm]
Pumpend L x W x H [mm]
Weight pumpend [kg]
Weight powerpack [kg]

HS300
Caterpillar C9
95
300
1800
13 h
685
Yes
160
3700x1700x2200
1401x1052x1830
945
5325

For additional specifications, see product technical documentation.


With reservation for changes.

68

Heidra series (Slurry gate)

HS100SG
40

(2000 rpm)

120

35

100

30
25

80
60

H (ft)

H (m)

HS100SG

20
15

40

10

20

5
0

0
0

10
50

20

30
100
Q

Model
Engine
Max. solids handling [mm]
Discharge [mm]
Max. operating speed [rpm]
Min. runtime @ max. speed
Fuel tank capacity [l]
Dry run capacity
Consumed power [kW]
Pumpend L x W x H [mm]
Powerpack L x W x H [mm]
Weight pumpend [kg]
Weight powerpack [kg]

40
150

50

60
200

I/s
m3/h

HS100SG
Perkins 403D-15
45
100
2000
18 h
72
Yes
14
480x580x700
1300x680x1900
145
945

For additional specifications, see product technical documentation.


With reservation for changes.

69

Godwin
hydraulic
submersible
pumps
Flygt submersible
drainage
pumps
Heidra series (Slurry gate)

HS150SG, HS150MRSG
50

160

(2000 rpm)

140

40

120

H (m)

100
80

20

60

HS150SG

H (ft)

HS150MRSG

30

40

10

20
0

0
0

20

40

100

60

80

200

300

100 120
400

I/s
3

500 m /h

Model

HS150G

HS150MRSG

Engine

Perkins
404D-22

Perkins
1104D-44T

Max. solids handling [mm]


Discharge [mm]
Max. operating speed [rpm]
Min. runtime @ Max. Speed
Fuel tank capacity [l]
Dry run capacity
Consumed power [kW]

65
150
2000
36 h
170
Yes
15

65
150
2000
51 h
390
Yes
41

PumpendLxWxH[mm]

725x680x1010
1800x520x570

700x650x800
2500x1300x1900

180
1052

170
2250

Powerpack L x W x H [mm]
Weight pumpend [kg]
Weight powerpack [kg]

For additional specifications, see product technical documentation.


With reservation for changes.

70

Heidra series (Slurry gate)

HS200SG
50

160

(2000 rpm)

140

40

120

H (m)

80
20
HS200SG

60

H (ft)

100

30

40

10

20
0

0
75 100 125 150 175 200

25

100 200 300 400 500


Q

Model
Engine
Max. solids handling [mm]
Discharge [mm]
Max. operating speed [rpm]
Min. runtime @ max. speed
Fuel tank capacity [l]
Dry run capacity
Consumed power [kW]
Pumpend L x W x H [mm]
Powerpack L x W x H [mm]
Weight pumpend [kg]
Weight powerpack [kg]

50

600

I/s

3
700 m /h

HS200SG
Perkins 1106D-E66TA (129)
75
200
2000
32 h
390
Yes
61
850 x 725 x 1300
2500x1300x1900
380
2250

For additional specifications, see product technical documentation.


With reservation for changes.

71

Godwin
hydraulic
submersible
pumps
Flygt submersible
drainage
pumps
Heidra series (Vortex slurry gate)

HS150VSG
30

100

(2000 rpm)

25

80

H (m)

HS150VSG

60

15
40
10
20

5
0

H (ft)

20

0
0

20
100

40

60
200

80
300

100

120

400

I/s
m3/h

Model
Engine
Max. solids handling [mm]
Discharge [mm]
Max. operating speed [rpm]
Min. runtime @ max. speed 23 h
Fuel tank capacity [l]
Dry run capacity
Consumed power [kW]
Pumpend L x W x H [mm]
Powerpack L x W x H [mm]
Weight pumpend [kg]
Weight powerpack [kg]

HS150VSG
Perkins 1104D-44T
125
150
2000
390
Yes
51
700x650x800
2500x1300x1900
170
2250

For additional specifications, see product technical documentation.


With reservation for changes.

72

Heidra series (Vortex)

HS150V
30

100

(2000 rpm)

25

80

20
H (m)

40
10
20

5
0

H (ft)

60

HS150V

15

0
0

20
100

40

60
200

80
300

100

120

400

I/s
m3/h

Model
Engine
Max. solids handling [mm]
Discharge [mm]
Max. operating speed [rpm]
Min. runtime @ max. speed
Fuel tank capacity [l]
Dry run capacity
Consumed power [kW]
Powerpack L x W x H [mm]
Pumpend L x W x H [mm]
Weight pumpend [kg]
Weight powerpack [kg]

HS150V
Perkins 1104-44T
125
150
2000
23 h
390
Yes
51
2500x1300x1900
577x514x816
161
2250

For additional specifications, see product technical documentation.


With reservation for changes.

73

Godwin
hydraulic
submersible
pumps
Flygt submersible
drainage
pumps
Heidra series (High head)

HS80HH, HS150HH
110

(2000 rpm)

350

100
300
250
200

60
HS150HH

40

150

HS80HH

H (ft)

H (m)

80

100
20
0

50
0

10

20 30

50

100

40

50 60

150
Q

200

70
250

80

I/s
3

300 m /h

Model

HS80HH

Engine

Perkins 1104D-44T Perkins 1106DE66TA (129)

Max.Solids handling [mm]


Discharge [mm]
Max.operating speed [rpm]
Min. runtime @ max. speed
Fuel tank capacity [l]
Dry run capacity
Consumed power [kW]

25
75
2000
31 h
390
Yes
44

35
150
2000
26 h
850
Yes
81

PowerpackLxWxH[mm]

2500x1300x1900
451x506x715

2950x1300x1900
664x770x1275

160
2250

190
2598

Pumpend L x W x H [mm]
Wight pumpend [kg]
Wight powerpack [kg]

HS150HH

For additional specifications, see product technical documentation.


With reservation for changes.

74

75

Accessories
for
Godwin
pumps
Flygt submersible
drainage
pumps

Accessories
Complement our extensive
range of Godwin pumps
with a wide range of
accessories that simplify
installation and operation.

Suction hoses

Discharge hose

Quick release pipe and adaptors

Wellpoint systems

Suction hoses with fitted strainer

76

77

Pumps
101 drainage pumps
Flygt submersible

Basic pump hydraulics


All pumping applications have three things in common :
Flow

Amount of liquid to be pumped


= Quantity divided by time1

Elevation

Gravity resistance
= Difference in vertical elevation from
source to termination2

Distance

Friction resistance, determined by the


diameter, flow and hose/pipe material =
Length of hose/pipe from source to
termination3

To size a permanent or temporary pumping application,


start by gathering data on flow, elevation and distance.

1
2
3

78

See page 79.


See page 80
See page 81, 84.

Flow determines pipe size


Liquid velocity is critical to
keep solids in suspension.
If velocity is too slow, solids
drop out. If it's too fast,
friction loss becomes an
Issue.

Flow

The chart on the right


shows four different
measurements for flow
along with the
corresponding hose/pipe
size in inches.
Determining the flow is the
first step in designing a
complete pump system
because flow determines
the size of the pipe. When
flow is not known, calculate
quantity and divide by the
time required to move the
liquid.

Flow = Quantity + Time


I/min Liters
Minute
I/sec Liters
Second
M3/hr Metres3 Hour
gpm Gallons
Minute
79

Pumps
101 drainage pumps
Flygt submersible

Elevation determines required pump


strength
It's not where the liquid is, but where it's going that
determines the strength of the pump required. Static
head is the difference in vertical elevation from the
product source to its termination point.
Elevation guidelines

Flygt

Godwin

0-15 m (50 ft.)

MT

CD

15-30 m (50-100 ft.)

HT

CD-Elevated head

30-60 m (100-200 ft.)

MT/ST/SH

HL

60-180 m (200-600 ft.) MT/ST/SH (Tandem) HL-Extreme head

Static head (verticle elevation difference)

ST/SH

HL

8.5 m/28 ft*

HT

CD

MT

*Maximum suction lift of a Dri-Prime pump is 8.5 m (28 ft.) at sea level.

80

Distance determines increase in pipe size


Every meter or foot of hose/pipe on suction or delivery
piping creates friction resistance*, which is added to the
static head (vertical elevation) .The longer the discharge
run, the more the friction. If the discharge length is too
long, friction can can be significantly reduced by
increasing the diameter of the hose or pipe. To maintain
the required flow over great distances, use these
guidelines :
Total length of hose/pipe :
Up to 300 m (1,000 ft.) Use the
recommended diameter of
hose/pipe according to the
flow requirements indicated c
page 79.
Over 300 rn (1,000 ft.) Increase
the diameter of hose/ pipe
according to the flow
requirements on page 79.
Example :
If a pump must transport 62 I/s
(1,000 US gpm) of product over
400 m (1300 ft), for instance,
you should increase the hose/
pipe diameter from 6" to 8".
*See page 84 for friction losses in pipes and hoses

81

Flygt submersible drainage pumps

Choosing the right pump


Once you have determined flow, lift and distance and
established the basic design of the pumping system, one
critical question remains :
What is being pumped?
Selecting the right pump ensures reliable operation to
get the job done. Choosing the wrong pump may cause
pump failure, service disruption and costly repair or
replacement. Generally speaking, go with a Godwin
when electric power is not readily available.
Pumped media

Applications

Recommended pumps
Flygt
Godwin

Clean or dirty
Water pH
range 5-8

* Mining
* Construction
* Municipal

2600 series Dri-Prime CD


series

Sludge
PH range 5-8

* Construction
* Municipal
* Industrial

2600 series Heidra series

Extreme pH
(Corrosive)
PH range 2-10

* Mining
* Industrial

2700 series Dri-Prime CD


and HL series

Slurry
(Abrasive)
PH range 5-9

* Mining
* Industrial
* Municipal

82

(With stainless
Steel pumpend)

5000 series

Distance determines increase in pipe size


To complete the pumping job successfully, proper
positioning of equipment is essential.
Submersible pumps (Flygt and Godwin Heidra):
The following three options for drainage pumps provide
reliable results.

1. Suspended

2. Supported

3. Surrounded

Sunk!

(Not by electric cable)

Surface-mounted suction lift pumps (Godwin Dri-Prime)


Keeping the suction lift to a minimum is the key to
successful surface
mounted pumping
applications. DriPrime pumps are
limited to a suction
lift of 8.5 m or 28 ft.
Critical suction lifts :
In applications
where suction lifts
are greater than 6 m
(20 ft), increase the suction hose size to reduce suction
velocity and then by prevent suction cavitation.

83

Pumps
101 drainage pumps
Flygt submersible

Friction losses in pipes and hoses


All pump capacities are measured for clean water,
directly at the discharge outlet. When connect~nga
hose, you must consider the friction losses that come
from the hose size and length. See the chart below.

2
3
3
4
(50 mm) (70 mm) (100 mm) (150 mm)

Friction losses (meters / 100 m of hose)

100
80
60

8 (200 mm)

40
20

10 (250 mm)

10
8
6

4 m/s

4
2
0.1
0.8
0.6

2 m/s

0.4
0.2
0.1
1

4 5

10

20

30 4050 70

Flow (l/s)

84

100

200 300

ApH tables
Aluminium
Cast iron and carbon steel
Zinc anodes and epoxy
Stainless steel
Sintered aluminium oxide
Cemented carbide
Silicon carbide
Nitrile rubber
Flourocarbon rubber (viton)
0

10

11

12

13

14

PH

Chloride tables

0.04

Aluminum
Cast iron and carbon steel
Stainless steel AISI 316
Stainless steel AISI 304
Sintered aluminum oxide
Cemented carbide
Silicon carbide
Nitrile rubber
Flourocarbon rubber (viton)

10

0.1

Salt water

% salt

27

+ Zinc anodes
+ Zinc anodes and epoxy
+ Zinc anodes
+ Zinc anodes
+ Zinc anodes

102

103
200

3.2

500

104

105
18000

Saturated
Pppm chlorides

85

Pumps
101 drainage pumps
Flygt submersible

Generator sizing chart


These are the recommended sizes of generators for Flygt
submersible drainage pumps.
Voltages 3 ~ 400V 50 Hz
Pump
model

Max. power
consumption

Rated
current
[A]

Permissible Delayed fuse Generator


cable length [A]
set [kVA]
[kW]
[m]

2610
2620
2630
2640
2660
2670
2125 HT
2201
2250
2400
2720
2730
2740
2750

1.6
2.7
4.5
6.7
11.7
20
10.2
41
62
95
2.7
4.1
7.3
9.4

2.7
4.7
7.3
11
19
32
16
65
104
148
4.4
8.8
12
15

270
200
215
145
130
115
95
100
100
35
200
190
130
165

10
10
16
25
32
63
32
100
190
230
10
16
25
32

5
8
13
18
25*/30
40*/50
25*/30
85*/105
125*/155
225*/270
8
10
20
25
*Y/D start

Voltages 1 ~ 230V 50 Hz
Pump
model

Max. power
consumption

Rated
current
[A]

Permissible Delayed fuse Generator


cable length [A]
set [kVA]
[kW]
[m]

Ready 4
Ready 8
Ready 8S
2610
2610
2620

0.59
0.97
1.2
1.2
1.7
1.9

2.7
4.2
5.2
5.1
7.2
8.5

60
60
50
70
50
50

86

10
10
16
10
16
16

3
3
3
4
5
5

Measurement conversion reference


Pressure

Power

Flow

Temp.

87

Monitoring
& drainage
controlpumps
Flygt submersible

Total control
Practical easy-to-use monitoring and control
systems are essential to get a complete overview of
your operations.
Whether you use a single pump or two or more in a
series, we can supply everything you need to ensure
continuous operation -from single pump controllers,
sensors and startup equipment to SCADA software
for complete fluid handling supervision.
Our monitoring and control systems help reduce
operational costs, minimize report handling and
improve environmental control.

88

Flygt
submersible
drainage pumps
Spare parts
& service

Extensive support
To provide you with outstanding support and service,
we have a global service network that spans 140
countries.
Our dedicated professionals are at work in over 175
service centers worldwide. Plus there are hundreds
of authorized Flygt and Godwin service partners who
also provide top-notch service and support.
All genuine Flygt and Godwin spare parts are backed
by solid availability guarantees.

89

Notes :

Xylem is a global provider of water handling and


treatment solutions for construction, mining,
municipal and industrial customers in more than 140
countries. The company designs and delivers energy
efficient solutions and related services for water and
wastewater transport, dewatering, biological
treatment, filtration, and disinfection. Xylem
maintains one of the industry's most extensive sales
and service organizations to ensure it meets more
than one customer's needs locally.