Sie sind auf Seite 1von 6

Note: Ensure that the calibration procedure for the governor actuator is performed when

the
governor actuator, the accelerator cable or the controller has been replaced or installed.
The
temperature of the hydraulic oil should be 50 C (122 F) prior to the calibration.

illustration 1
g00777652
The above illustration is an example of the display for the 312C. All of the other displays are identical
with
the sales model on the fourth line.

Enter 1. the service mode.

Illustration 2 g00825978

Highlight the second line of the display and use the direction for direction to scroll
through
the display. Scroll through the display until the display shows "CALIBRATION".
2.

Illustration 3 g00790593

Highlight the third line by using the keys for direction. The name of the device will be
shown on the third line. Scroll downward until "STANDBY" is highlighted. Press the
"OK"
key in order to start the calibration procedure. "GOVERNOR-EXE" is displayed on the
third line when the governor actuator is calibrated. Press the "OK" key after confirming
the
display of "GOVERNOR-EXE".
3.

Illustration 4 g00790592

The above illustration shows a display that is temporarily shown when the governor
actuator
is moved to the initial position. Press the "OK" key again when the display shows "SP".
The
calibration procedure has started.

4.
Illustration 5 g00790597

The numerical number that is being displayed in the fourth line will change during the
calibration. This number is related to the process of the calibration. See the following
table
Table 1
Content For The Process
Display
STANDBY

Process
Prior to calibration

Transfer of the initial position of the governor actuator

SP

The initial transfer of the information about the position has been
completed.

High idle search

Positioning of the high idle

Data collection of the intermediate points (9-2) down

Low idle search

Data acquisition of intermediate points (2-9) up

Confirmation of the high idle

Confirmation of the setting for the speed dial (down)

10

Confirmation of the setting for the speed dial (up)

11

End processing

Illustration 6 g00790598

6. The above illustration is shown after the governor actuator has completed
the calibration.

Warnings
If the fourth line of the display shows any of the following warnings a failure is present.
See the
following table 2 for a detailed description of the warning displays.
Table 2
Warning Codes
Display

Warning

Corrective Action

Wire nut is installed too


Wire Pitch X (X loose by X pitch. X can Tighten the accelerator cable by the
is a number from be a positive or
displayed pitch. Perform the calibration
0 to 9)
negative number. Turn again.
clockwise.
Wire nut is installed too
Wire Pitch X (X tight by X pitch. X can Loosen the accelerator cable by the
is number from be a positive or
displayed pitch. Perform the calibration
-9 to 0)
negative number. Turn again.
clockwise.

WARNING 01

WARNING 02

Insufficient high idle

High idle is less than the specified value due


to malfunction of the engine, incorrect
installation of the governor cable, poor fuel,
etc. After the engine has been inspected for
a malfunction, reinstall the cable and
perform the calibration again.

Incorrect installation of Reinstall the cable and perform the


cable
calibration again.

WARNING 03

WARNING 04

WARNING 05

WARNING 06

Excessive low idle

Low idle is more than the value specified


due to a malfunction in the engine, an
incorrectly installed governor cable, etc.
After the engine has been inspected,
reinstall the cable and perform the
calibration again.

Excessive hysteresis

Ensure that the cable is adjusted correctly.


Reinstall the cable and perform the
calibration again.

Unstable high idle

High idle is unstable due to a malfunction in


the engine, an incorrect installation of the
governor cable, etc. After the engine has
been inspected, reinstall the cable and
perform the calibration again.

Unstable dial speed

The speed for the dial setting is unstable due


to a malfunction in the engine, an
incorrectly installed cable, etc. After the
engine has been inspected, reinstall the
cable and perform the calibration again.

Errors
If the fourth line of the display shows any of the following errors a failure is present.
See the
following table for a detailed description of the error displays.
Table 3
Error Codes For The Governor Actuator
Error
Code

Description Of The Error

ERROR
01

Improper calibration of
another device

Stop the calibration of the other device.


Perform one calibration at a time.

ERROR
02

Improper calibration of
another module

Stop the calibration of the other device.


Perform one calibration at a time.

ERROR
03

Failure of the interlock


signal

Perform the troubleshooting procedure that


will confirm the signal that communicates
with the monitor.

ERROR
11

Abnormal speed sensor

Troubleshoot the confirmation of the speed


sensor.

ERROR
12

Engine stop

Perform the calibration again. Try to prevent


the engine from stopping.

ERROR

Load available

Reset all operational levers to the neutral

Corrective Action

13

position. Perform the calibration again.

ERROR
14

Overheating of the coolant or You need to allow the complete cooldown.


the hydraulic oil during the
Clear the overheating condition. Perform the
calibration
calibration procedure again.

ERROR
15

Pressure decrease in the


engine oil
Check for clogged air
cleaner

Clear the abnormal occurrence and perform


the calibration again.

ERROR
16

Excessive governor
movement time

Troubleshoot the confirmation of the


governor actuator.

Perform the following procedure when the data for the calibration of the governor
actuator is cleared.

Das könnte Ihnen auch gefallen