Sie sind auf Seite 1von 4

A

2 OF D50=12" RIPRAP

US Army Corps
of Engineers

W/ 6" BEDDING LAYER

1 1/2 " DIA SCHEDULE


80 AL PIPE

Jacksonville District

1-1"

Approved

SAFETY ON THIS JOB


DEPENDS ON YOU

B
S105
BRIDGE ABUTMENT
2-6"

SERRATED GALVANIZED

2-6"

GRATING: GW-125
OR EQUIVALENT
HANDRAIL

SEE DWG S106


FOR TYPICAL

1-1"

3-6"

1 1/4 " X 3/16 " BEARING BAR


SEE DETAIL A ON

WP

HANDRAIL DETAIL

DWG S106 FOR


SUPPORT DETAIL
SPAN
1-9"

1 1/4 " X 3/16 " BEARING BAR

20-0"

10-6"

8-0"

6-3"

5-0"

A
Description

OR EQUIVALENT

S105

BRACKET

SPAN

1 1/2 "

1-0"

1-4"

4-0"

S105

GRATING: GW-125

8-6"

SERRATED GALVANIZED

SPAN

90

PLATFORM
REMOVABLE GRATING
GATE POSITION

3"

GRATING FASTENED TO

SENSOR HOUSING

CHANNEL WITH STAINLESS


MOUNT

STEEL CONNECTORS

C 10 X 20

STAFF

1 1/2 "

GALVANIZED

13-9"

7-6"

GAGE

STEEL

Zone

HERE

Symbol

4-0"

3
10 (X8 WIDE)

1
EL H

1
21-3"

4
EL I

NOTE:

SEE DETAIL A

HANDRAIL @ GATE WELL NOT SHOWN FOR CLARITY.

AL PIPE

IS PERPENDICULAR
TO LEVEE ALIGNMENT

HANDRAIL (TYP)

HANDRAIL NOT SHOWN FOR CLARITY.

SEE DWG S107

SEE DWG S107 FOR LAYOUT AND

FOR DETAILS

CONNECTION DETAIL (DETAIL A).

SCALE:

"C"

Inv. No.

CONTROL GATE AND LEVEE SECTION


EL A

NOVEMBER 2002

LEVEE, PLATFORM

SLIDE GATE
DOWNWARD OPERATING

ABUTMENT
1-6"

5-0"
EL E

1-3" TYPICAL

CONTROL GATE ELEVATION TABLE


36" RCP
SEPARATION LEVEE
(G1)

CJ EL G

CULVERT
2 OF D50=12" RIPRAP

(G2)

ELEVATION
WORKING POINT:

WORKING POINT:

X = 710476.722

X = 711786.049

Y = 1081342.548

Y = 1077652.381

27.88

26.88

24.60

24.50

24.10

23.50

1-3"

LOCATION

OUTFALL STRUCTURE

6"

GATE ELEVATION

5-0"

NOTES:

SECTION
SCALE: "A"

6" BEDDING LAYER

A-S105
S105

1. RAILING FRAME FOR SLIDE GATE IS MOUNTED ON ANCHOR BOLTS IN GATE WELL WALL.
D

22.60

22.00

21.00

18.50

18.50

17.50

17.50

16.50

23.50

N/A

18.50

13.50

24.00

22.00

2. PEDESTAL MOUNTED GATE OPERATOR IS SUPPORTED BY BRACKET MOUNTED ON ANCHOR

TAYLOR
CREEK

SEE SLIDE GATE MANUFACTURER FOR SPECIFICATIONS.

BOLTS IN GATE WELL WALL. BRACKET IS AVAILABLE FROM SLIDE GATE MANUFACTURER.

3. FOR CONTROL GATE LOCATIONS, SEE DWGS C110 AND C111.

GATE SIZE

4. ALL HARDWARE SHALL BE HOT-DIPPED GALVANIZED AS REQD.

5. ALL CONTROL GATES TO WITHSTAND UNSEATING HEAD 5-0" OR GREATER.


60X24

SCALE:

PHOSPHORUS REMOVAL PROJECT

EL F
LAKE OKEECHOBEE WATER RETENTION/

S 391

2-0"

S 392

File name:

12-3"

Dated:

RW

STRUCTURAL

(ALL AROUND)
BRIDGE

STORMWATER TREATMENT AREAS

EL D

EH

EL C
CJ @ EL J

BRDR2D.DGN

BRIDGE ONLY

Reference files:

AT ACCESS

TAYLOR CREEK - GRASSY ISLAND

MFG.

Dwn by:

ON DWG S106

EL B

S105CNTLGT.DGN

BERM

RECOMMENDED BY MFG.

BY GATE

EH

SEE DETAIL B

Designed by:

ANCHOR BRACKET AS

BRACKET

3-4"

DETAIL B ON DWG C114

Ckd by:

GATE G1 IS SHOWN, FOR GATE G2 SEE

"A"

DRAWING NO.

60X30
6. FOR OTHER EQUIPMENT LOCATED OFF OR NEAR CONTROL GATE SEE DWG E111.

SCALE:

"B"

S105

RECORD DRAWING
$$$$$$SYTIME$$$$$$

$$$$$$$DGNSPECIFICATION$$$$$$$

CONTROL GATE

TRANSITION LENGTH

GATE OPERATOR

SCHEDULE 80

Plot scale: XX:X

BRIDGE

08/08/02

EDGE OF TOP OF

PEDESTAL MOUNTED

1 1/2 " DIA

Plot date:

STRUCTURE OVER 25

ON DWG S106

AS SHOWN

ACCESS

XX/XX/02

WP LOCATED AT

Dated:

SLOPE AT CONTROL

DACWxx-02-x-xxxx

W/6" BEDDING LAYER

SEE DETAIL C

D.O.FILE NO.

TRENCH 4:1 SLOPE TO 3:1


2 OF D50-12" RIPRAP

402-38, 292

ON DWG S106

TRANSITION DEEP ZONE

WEST PALM BEACH, FL 33406

ORIGINAL GROUND

PHONE (561)689-7444 FAX (561)689-3003

12-0"

STANLEY CONSULTANTS, INC.

DEPARTMENT OF THE ARMY

C
L LEVEE

1601 BELVEDERE ROAD, SUITE 400 EAST

SCALE: "A"

PREPARED BY:

S105

CONTROL GATE PLAN

JACKSONVILLE, FLORIDA

S105

Scale:

"B"

JACKSONVILLE DISTRICT, CORPS OF ENGINEERS

SCALE:

B-S105

PLAN & SECTIONS

SECTION

No.

12-0"

US Army Corps
of Engineers
Jacksonville District
SAFETY ON THIS JOB
DEPENDS ON YOU

STEEL

2-0"

(TYP)
1. STRUCTURAL STEEL IS DESIGNED IN ACCORDANCE WITH AND

2 ADDL. #5 BARS

WORK SHALL CONFORM TO THE LATEST EDITIONS OF

EACH FACE

#5 @ 12"

Approved

#5 @ 12"

ADDL. #7 X 5-0"

"SPECIFICATIONS FOR DESIGN, FABRICATION AND ERECTION

EACH CORNER @

OF STRUCTURAL STEEL FOR BUILDINGS" (AISC), "CODE OF

BLOCKOUT (TYP.)

STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES"


(AISC) AND "STRUCTURAL WELDING CODE- STEEL (AWS.)
STRUCTURAL STEEL SHALL BE NEW STEEL CONFORMING TO
ASTM A572, FY = 50 KSI, UNLESS OTHERWISE NOTED.
2. CONNECTIONS:
A. BEAM CONNECTIONS SHALL BE STANDARD FRAMED BEAM
CONNECTIONS.

A
S106

#5 @ 12"

AND FABRICATOR SHALL SUBMIT PROPOSED CONNECTION

(TYP)

2-0"

S106

B. CONNECTIONS SHALL BE BOLTED OR WELDED OR BOTH,

DETAILS FOR APPROVAL PRIOR TO FABRICATION.


C. BOLTED CONNECTIONS SHALL BE MADE WITH 3/4"
DIAMETER ASTM A325 HIGH-STRENGTH STEEL BOLTS AND

3 ADDL. #7 BARS

Description

12-6"

LOAD INDICATING DEVICES.

EACH FACE

D. WELDED CONNECTIONS SHALL BE MADE BY A CERTIFIED


WELDER IN ACCORDANCE WITH AWS D.1.1, USING CLASS
E70 SERIES ELECTRODES. WELDS SHALL DEVELOP THE
FULL STRENGTH OF THE MATERIALS BEING WELDED, UNO.

DETAIL

E. ANCHOR BOLTS SHALL BE STAINLESS STEEL TYPE 316.

ADDITIONAL REINFORCING

3. ALL EXPOSED STRUCTURAL STEEL, COMPONENTS AND FITTINGS

FOR SLIDE GATE OPENING

SHALL BE HOT DIPPED GALVANIZED (2 OZ/ SQ. FT.) AFTER

N.T.S

FABRICATION IN COMPLIANCE WITH ASTM-A123. GALVANIZER


SHALL FURNISH, TO CONTRACTING OFFICER A NOTARIZED
CERTIFICATE OF COMPLIANCE WITH THESE SPECIFICATIONS.
4. ANCHOR BOLTS AND BEARING PLATES SHALL BE LOCATED BY
TEMPLATES OR SIMILAR METHOD. PLATES SHALL BE SET IN

CONTROL GATE PLAN

Zone

FULL BEDS OF NON-SHRINK GROUT. BOTTOM OF BASE PLATES


SHALL BE SET APPROXIMATELY 3/4" ABOVE TOP OF BEARING.

Symbol

RESULTING SPACE SHALL BE FILLED WITH DRY PACKED NON-

SCALE: "A"

SHRINK GROUT.
5. STEEL FRAMING SHALL BE TRUED AND PLUMB BEFORE

No.

CONNECTIONS ARE PERMANENTLY BOLTED OR WELDED.

4"

6. TEMPORARY ERECTION BRACING AND SUPPORTS SHALL BE


PROVIDED TO HOLD STRUCTURAL STEEL FRAMING SECURELY IN
POSITION. SUCH TEMPORARY BRACING AND SUPPORTS SHALL

AND WHERE SHOWN ON THE DRAWINGS.


8. FIELD CUTTING OR ANY OTHER FIELD MODIFICATIONS OF

9"

5 #6

STRUCTURAL STEEL SHALL NOT BE MADE WITHOUT APPROVAL

L 4 X 4 X 3/8 X 6 LONG

FROM CONTRACTING OFFICER FOR EACH SPECIFIC CASE.

GALVANIZED

2"

#7 @ 12"

#5 @ 12"

(WALL W/GATE
2"

OPENING ONLY)

3/4 " DIA ASTM A325 HIGH-STRENGTH


STEEL BOLT

WEST PALM BEACH, FL 33406

CONCENTRATIONS ON SUPPORTING MEMBERS OVER ALL COLUMNS

#5 @ 12"

PHONE (561)689-7444 FAX (561)689-3003

#5 @ 12"

STANLEY CONSULTANTS, INC.

7. MILLED STIFFENERS SHALL BE PROVIDED UNDER ALL LOAD

ANCHOR BOLT

DEPARTMENT OF THE ARMY

1601 BELVEDERE ROAD, SUITE 400 EAST

3/4 " DIA SST

PREPARED BY:

SPECIFIED CONCRETE STRENGTH.

#5 @ 12"

JACKSONVILLE, FLORIDA

INSTALLED AND FLOOR SLABS HAVE ATTAINED 75% OF

12-6"

JACKSONVILLE DISTRICT, CORPS OF ENGINEERS

NOT BE REMOVED UNTIL PERMANENT BRACING HAS BEEN

C 10 X 20

1 1/4 " X 3/16 " BEARING

3"

1 1/2 "

@ EACH POST

STRINGER (GALV)
1/2 " X 6" WELDED HEAD

1/4 "

5"

STUB (GALV.) @ 18" O.C.

C 10 X 20 STRINGER (GALV)
L 4 X 4 X 1/4 X 6 LONG
GRATING BEARING BARS

GALVANIZED

(SHOWN LONG., MAYBE TRANS)

DETAIL
SCALE:

"B"

B-S106
S105

DETAIL
SCALE:

C-S106

"B"

S105

L 1 1/2 X 1 1/2 X 1/4 (GALV.)

1
2

DETAIL
ANGLE
N.T.S.

SCALE:

A-S106
S105

402-38, 292

NOVEMBER 2002

Plot scale: XX:X

08/08/02
Plot date:

Scale:

RW

DRAWING NO.

"A"

SCALE:

S106

6IN

"B"

RECORD DRAWING
$$$$$$SYTIME$$$$$$

$$$$$$$DGNSPECIFICATION$$$$$$$

REINFORCING & DETAILS

PL 1/4 X 5 X 6 1/2

1/2 "

1/4 "

C 10 X 20

1/4 "

S106

CONTROL GATE

3"

S106

1 1/2 "

STRUCTURAL

STORMWATER TREATMENT AREAS

S106

1 1/2 "

HIGH-STRENGTH STEEL BOLT


SCALE: "A"

LAKE OKEECHOBEE WATER RETENTION/

3/4 " DIA ASTM A325

1 1/2 "

A-S106

File name:

BAR (GALV)

SECTION

AS SHOWN

XX/XX/02
Dated:

SERRATED BAR GRATING

1/2 "

#5 @ 12"

#5 @ 12"

D.O.FILE NO.

ACCESS BRIDGE

Dated:

3/4 " DIA SST


ANCHOR BOLT

BRDR2D.DGN

BAR (GALV)

Reference files:

1 1/4 " X 3/16 " BEARING

EH

AL GUARDRAIL POST

SERRATED BAR GRATING

TAYLOR CREEK - GRASSY ISLAND

#5 @ 12"

Ckd by:

ACCESS BRIDGE
#5 @ 12"

Designed by:

C
L POST

Dwn by:

S106

S106RNFC.DGN

"B"

PHOSPHORUS REMOVAL PROJECT

SCALE:

B-S106

Inv. No.

SECTION

EH

DACWxx-02-x-xxxx

STRINGER (GALV)

US Army Corps
of Engineers
5-0" TYP

1-6"

Jacksonville District
SAFETY ON THIS JOB
DEPENDS ON YOU

1 1/2 " DIA


SCHEDULE 80

1-1"

3-6"

Approved

AL PIPE (TYP)

1-4"

C
L POST

A
S107

2- 3/8 " DIA TYPE 316 SST HEX HEAD

NOTE:

C
L POST

CAP SCREWS 90^ BETWEEN CENTERS,

1 1/2 " DIA SCHEDULE

WITH THREADED BOSS WELDED TO

80 AL PIPE POST

1 1/2 "

PIPE. PROVIDE 1/2 " DIA HOLE


1/4 "

IN SLEEVE.

UNLESS SHOWN OTHERWISE. SEE DETAIL THIS SHEET FOR

AL GUARDRAIL POST

(TYP)

GUARDRAIL @ GATE WELL.

TYP

Description

DETAIL APPLIES TO ACCESS BRIDGE AND INTAKE STRUCTURE,

1/4 " X 4" AL KICKPLATE

3/16

2 - 1/4 " AL U-BOLTS


1 1/2 "

40 AL PIPE SLEEVE

TYPICAL GUARDRAIL DETAIL

2"

2" DIA SCHEDULE

N.T.S.

2"

4" LEG

4"

2"

BEND 90^

1 3/4 " BEVEL

IN ANGLE

AL PIPE (TYP). THREE RAILS,

13/16 " DIA HOLES

2 - 3/4 " DIA SST

SEE DETAIL ABOVE FOR

SLOTTED TO

ANCHOR BOLTS

RAIL HEIGHTS.

Symbol

1 1/2 " DIA SCHEDULE 80

Zone

3/4 " DIA WEEPHOLE

EACH END

1 1/2 " HORIZ


TACK WELD
AL L 4 X 3 X 5/8

SCALE: "A"

S105

S107

SEE DETAIL A THIS DWG.

GATE WELL GUARDRAIL DETAIL

WEST PALM BEACH, FL 33406

A-S107

CLR

1/2 "

6"

POCKET

AL PIPE SLEEVE

EA. FACE SAME SIZE AS

SEE RAILING
PL 3" DIA X 1/8 "

PLANS

WALL REINFORCING (TYP.)

DETAIL
BASE SLAB

SCALE: "A"

B-S107
S108

SECTION

B-S107

SCALE: "A"

S107

LAP SPLICE
MAX. OF 2 ADDITIONAL BARS
OR 1/2 OF BARS INTERRUPTED
BY OPENING ON EACH SIDE OF
OPENING, EA. FACE, SAME SIZE

AS WALL REINFORCING (TYP.)

PHOSPHORUS REMOVAL PROJECT

1 ADDITIONAL BAR

LAKE OKEECHOBEE WATER RETENTION/

1/8

PIPE PENETRATION DETAIL


ADDITIONAL REINFORCING

DRAWING NO.

FOR ROUND OPENINGS


N.T.S.
6

SCALE: "A"

S107

6IN

RECORD DRAWING
$$$$$$SYTIME$$$$$$

$$$$$$$DGNSPECIFICATION$$$$$$$

D.O.FILE NO.

NOVEMBER 2002
Dated:

EH

STRUCTURES

GROUT

SCHEDULE 40

STORMWATER TREATMENT AREAS

File name:

4" DIA

2" DIA

BRDR2D.DGN

3" CHAMFER

Reference files:

VARIES

TAYLOR CREEK - GRASSY ISLAND

1/2 "

4-0" FOR 0=48"

3-0" TYP.

DIAMETER

2"

OPENING

1"

1/4 "

S107DETL.DGN

AL PIPE SLEEVE

3/16

EH

TYP

Designed by:

80 AL PIPE POST

4-0" FOR 0=48"

RW

AL GUARDRAIL POST

1 1/2 " DIA SCHEDULE

3-0" TYP.

MISCELLANEOUS DETAILS

1/8

Dated:

IN SLEEVE

Plot scale:

2"

08/08/02

S107

Ckd by:

PROVIDE 1/2 " DIA HOLE

Dwn by:

WELDED TO PIPE.

C
L POST

Inv. No.

WITH THREADED BOSS

Plot date:

BETWEEN CENTERS,

Scale:

CAP SCREWS 90^

XX/XX/02

DACWxx-02-x-xxxx

316 SST HEX HEAD

AS SHOWN

2"
2 - 3/8 " DIA TYPE

402-38, 293

C
L POST

N.T.S.

PHONE (561)689-7444 FAX (561)689-3003

SCALE: "A"

FOR CONNECTION DETAIL,

SECTION

A-S107

STANLEY CONSULTANTS, INC.

DETAIL
3-6" HIGH POST.

PREPARED BY:

1601 BELVEDERE ROAD, SUITE 400 EAST

1 3/4 " PROJECTION

(LLV)

JACKSONVILLE, FLORIDA

1 1/2 "

DEPARTMENT OF THE ARMY

4"

8"

JACKSONVILLE DISTRICT, CORPS OF ENGINEERS

1 1/2 "

No.

2"

1/2 "

TRASH RACK

1/8 " TOOLED EDGE

1/8 " TOOLED EDGE

US Army Corps
of Engineers

T
T/3

Jacksonville District

T/3

T/3

1-1"
SAFETY ON THIS JOB
DEPENDS ON YOU

SEALANT

1"

SCHEDULE 80
AL PIPE (TYP)

1-4"

MATERIAL

1 1/2 " DIA

1 1/2 "

1/2 " EXPANSION

Approved

CENTERED

1/2 "

#5 @ 14"
(MAX. SPACING)

OR FIBER CAP.

9"

EL 26.00

CONST. JOINT
W/KEYWAY

WATERSTOP
(AS NEEDED)

APPROVED METAL

NOTE: PROVIDE V-JOINT AT EXPOSED

HORIZONTAL CONSTRUCTION JOINTS.

TYPICAL V-JOINT DETAIL

TYPICAL EXPANSION JOINT DETAIL

S107

S110
Description

N.T.S.
N.T.S.

(+/-) 8 1/16 "

(+/-) 9 3/8 "

13-10"

CJ EL 19.0

1/8 " TOOLED

Zone

EDGES

NOTE:

1-0" X 7 X 1/2 X 19-2" LONG

1/2 " X 3" EXPANSION


JOINT LINE

Symbol

TRASH RACK SCRAPERS

MATERIAL

SST BENT PLATE

9-6"

EL 10.50

CONTRACTION JOINT DETAIL

11-6"
2-4"

TRASH RACK SUPPORT DETAIL

N.T.S.
STEP FOR SUPPORTING

N.T.S.

BOTTOM OF TRASH RACK


EL 8.17

5-6"

5-6"

1-8"

19-2"

1-8"

1 1/2 " DIA

TRASH RACK

SCHEDULE 80

5-0"

ELEVATION

AL PIPE (TYP)
(TYP)

SCALE: "A"

A-S109
S108

NOTE:
TRASH RACK CONNECTION

WEST PALM BEACH, FL 33406

1"

ALTERNATE LEGS

DEPARTMENT OF THE ARMY

1-8"

WHERE SHOWN.
AS SHOWN @ 1-0" OC,

PHONE (561)689-7444 FAX (561)689-3003

"

STANLEY CONSULTANTS, INC.

EL 12.17

1601 BELVEDERE ROAD, SUITE 400 EAST

X 1-2" W/ 2" HOOK EA END

36

IE 13.00

PREPARED BY:

ABUTMENT CONTRACTION JOINTS,

JACKSONVILLE, FLORIDA

NOTE: PROVIDE JOINT MATERIAL AT

ANCHOR BARS 2 X 3/8

JACKSONVILLE DISTRICT, CORPS OF ENGINEERS

1-0"

No.

NOT SHOWN FOR CLARITY

DETAIL AT TOP PER FABRICATOR


5-0"

REINFORCING @
SLOPING STEMWALL
(TYP)

Dated:

D.O.FILE NO.

Plot scale:

RW
EH

Ckd by:

# 5 EF

Dwn by:

AL PIPE (TYP)

2 ADDITIONAL

BRDR2D.DGN

SEE DWG C113 FOR LENGTH

SCHEDULE 80

Reference files:

13-10"

CJ EL 19.0

TO PUMP STATION (DWG S101),

1 1/2 " DIA

13-10"

#5 @ 12 (TYP)

1
Designed by:

#7 @ 6

1-6"

File name:

#5 @ 12 EF

10-0"

NOVEMBER 2002

2
LENGTH VARIES

#5 @ 1-0" MAX

Dated:

Inv. No.

0"

#7 @ 6" MAX

OF WINGWALL

S109RNFC.DGN

1-0"

20

ANGLED PORTION

08/08/02

EL 26.00

6"

EL 26.00

Plot date:

#4 @ 1-6" MAX

CONCRETE PAD

AS SHOWN

10 X 24

EH

Scale:

1/2 " EXP. JT. W/ POLYURETHENE JOINT SEALANT

XX/XX/02

DACWxx-02-x-xxxx

TYP.

1-0"

#7 @ 6 EF

1-8"

EL 12.17

#7 @ 6

#7 @ 6" W/

#7 @ 6"

STANDARD HOOK

#5 @ 12" (TYP)

8-10"

5-6"

2-4"

EL 10.5
2-4"

4-0"

LENGTH VARIES

1-8"

7-0"

STRAIGHT PORTION
OF WINGWALL
EL 8.17

10-0"

1-8"

SECTION

16-0"

NOTE:

C-S109

ELEVATION

DRAWING NO.

B-S109

S109

SEE DWG S107 FOR PIPE

SCALE: "A"

S108

SCALE: "A"
PENETRATION DETAIL.

S108

SCALE:

"A"

RECORD DRAWING
$$$$$$SYTIME$$$$$$

$$$$$$$DGNSPECIFICATION$$$$$$$

ELEVATION, REINFORCING AND DETAILS

13.00

INTAKE STRUCTURE

OF SAND

SLOPED PIPE

#5 EACH FACE

STRUCTURAL

INV EL

FLOW

STORMWATER TREATMENT AREAS

2 ADDITIONAL

60

(+/-) 6" LAYER

#5 @ 12 EF

THIS SHEET

FLOW

PHOSPHORUS REMOVAL PROJECT

SEE TRASH RACK


SUPPORT DETAIL

LAKE OKEECHOBEE WATER RETENTION/

PIPE & WALL

5-10"

36"

GROUT BTWN

TAYLOR CREEK - GRASSY ISLAND

EL 18.00