Sie sind auf Seite 1von 25

Hardware Configuration

SIMATIC S7
Siemens AG 2002. All rights reserved.

Date:
File:

25.06.2006
PRO1_04E.1

SITRAIN Training for


Automation and Drives

Objectives

Upon completion of this chapter the participant will ...


...

be able to insert a hardware station into a project

...

be able to create a setpoint configuration and assign parameters to it

...

be able to read out an actual configuration and assign parameters to it

...

be familiar with the addressing of S7-300 input and output modules

SIMATIC S7
Siemens AG 2002. All rights reserved.

Date:
File:

25.06.2006
PRO1_04E.2

SITRAIN Training for


Automation and Drives

Hardware Configuration and Parameter Assignment


Configuration

Parameter assignment

Assignment of racks, blocks and distributed


I/O in the Hardware Configuration tool.
You can select the components from a
hardware catalog.

Parameter assignments such as retentive


areas, scan cycle time, and set-up of
analog input cards

Setpoint configuration

Planned hardware configuration and


parameter assignment.

Actual configuration

Actual configuration and parameter assignment


of existing hardware.

SIMATIC S7
Siemens AG 2002. All rights reserved.

Date:
File:

25.06.2006
PRO1_04E.3

SITRAIN Training for


Automation and Drives

Inserting a Station

SIMATIC S7
Siemens AG 2002. All rights reserved.

Date:
File:

25.06.2006
PRO1_04E.4

SITRAIN Training for


Automation and Drives

Starting the HW Configuration Editor

SIMATIC S7
Siemens AG 2002. All rights reserved.

Date:
File:

25.06.2006
PRO1_04E.5

SITRAIN Training for


Automation and Drives

Generating a Hardware Setpoint Configuration

SIMATIC S7
Siemens AG 2002. All rights reserved.

Date:
File:

25.06.2006
PRO1_04E.6

SITRAIN Training for


Automation and Drives

Addressing S7-300 Modules


Slot No.

Modules

PS

CPU

SM

SM

SM

SM

10

11

SM

SM

SM

SM

Address 0.0
Address 0.7
Address 1.0
Address 1.7

SIMATIC S7
Siemens AG 2002. All rights reserved.

Date:
File:

25.06.2006
PRO1_04E.7

SITRAIN Training for


Automation and Drives

DI/DO Addressing in Multi-Tier Configurations


PS

Rack
3

(Receive)

PS
Rack
2

IM
(Receive)

PS
Rack
1

PS
Rack
0
Slot

IM

CPU

SIMATIC S7
Siemens AG 2002. All rights reserved.

96.0
to
99.7

100.0
to
103.7

104.0
to
107.7

108.0
to
111.7

112.0
to
115.7

116.0
to
119.7

120.0
to
123.7

124.0
to
127.7

64.0
to
67.7

68.0
to
70.7

72.0
to
75.7

76.0
to
79.7

80.0
to
83.7

84.0
to
87.7

88.0
to
91.7

92.0
to
95.7

52.0
to
55.7

56.0
to
59.7

60.0
to
63.7

32.0
to
(Receive)
35.7

36.0
to
39.7

40.0
to
43.7

44.0
to
47.7

48.0
to
51.7

(Send)

0.0
to
3.7

4.0
to
7.7

8.0
to
11.7

12.0
to
15.7

16.0
to
19.7

IM

IM

Date:
File:

25.06.2006
PRO1_04E.8

20.0
to
23.7
9

24.0
to
27.7
10

28.0
to
31.7
11

SITRAIN Training for


Automation and Drives

Module Address Overview

Address Overview

SIMATIC S7
Siemens AG 2002. All rights reserved.

Date:
File:

25.06.2006
PRO1_04E.9

SITRAIN Training for


Automation and Drives

Variable Addressing

2x

SIMATIC S7
Siemens AG 2002. All rights reserved.

Date:
File:

25.06.2006
PRO1_04E.10

SITRAIN Training for


Automation and Drives

HW Config: Edit Symbols, Monitor/Modify Variables

1x right

SIMATIC S7
Siemens AG 2002. All rights reserved.

Date:
File:

25.06.2006
PRO1_04E.11

SITRAIN Training for


Automation and Drives

CPU Propertires: Cycle / Clock Memory

Double-click

Clock Memory Bit


Frequency (Hz)
Period (s)

SIMATIC S7
Siemens AG 2002. All rights reserved.

0.5 0.62
2

1.6

1.25

2.5

10

0.8 0.5 0.4 0.2 0.1

Date:
File:

25.06.2006
PRO1_04E.12

SITRAIN Training for


Automation and Drives

Saving the HW Setpoint Configuration and Downloading it in Module

Download
(only when CPU
is in STOP mode)

SIMATIC S7
Siemens AG 2002. All rights reserved.

Date:
File:

25.06.2006
PRO1_04E.13

SITRAIN Training for


Automation and Drives

Uploading the Actual HW Configuration to the PG/PC

SIMATIC S7
Siemens AG 2002. All rights reserved.

Date:
File:

25.06.2006
PRO1_04E.14

SITRAIN Training for


Automation and Drives

Exercise: Upload Actual Configuration to the PG/PC and Rename It

Result

SIMATIC S7
Siemens AG 2002. All rights reserved.

Date:
File:

25.06.2006
PRO1_04E.15

SITRAIN Training for


Automation and Drives

Exercise: Adapting the ACTUAL Configuration

SIMATIC S7
Siemens AG 2002. All rights reserved.

Date:
File:

25.06.2006
PRO1_04E.16

SITRAIN Training for


Automation and Drives

Exercise: Copy Block from "My_Program"

1.

2.

3.

SIMATIC S7
Siemens AG 2002. All rights reserved.

Date:
File:

25.06.2006
PRO1_04E.17

SITRAIN Training for


Automation and Drives

Exercise: Assign Parameters to CPU Clock Memory and Test

SIMATIC S7
Siemens AG 2002. All rights reserved.

Date:
File:

25.06.2006
PRO1_04E.18

SITRAIN Training for


Automation and Drives

CPU Properties

2x

SIMATIC S7
Siemens AG 2002. All rights reserved.

Date:
File:

25.06.2006
PRO1_04E.19

SITRAIN Training for


Automation and Drives

CPU Properties: General

SIMATIC S7
Siemens AG 2002. All rights reserved.

Date:
File:

25.06.2006
PRO1_04E.20

SITRAIN Training for


Automation and Drives

CPU Properties: Startup

SIMATIC S7
Siemens AG 2002. All rights reserved.

Date:
File:

25.06.2006
PRO1_04E.21

SITRAIN Training for


Automation and Drives

CPU Properties: Retentive Memory

Relevant only if CPU


has no backup
battery

SIMATIC S7
Siemens AG 2002. All rights reserved.

Date:
File:

25.06.2006
PRO1_04E.22

SITRAIN Training for


Automation and Drives

CPU Properties: Protection

SIMATIC S7
Siemens AG 2002. All rights reserved.

Date:
File:

25.06.2006
PRO1_04E.23

SITRAIN Training for


Automation and Drives

CPU Properties: Diagnostics / Clock

SIMATIC S7
Siemens AG 2002. All rights reserved.

Date:
File:

25.06.2006
PRO1_04E.24

SITRAIN Training for


Automation and Drives

CPU Properties: Communication

SIMATIC S7
Siemens AG 2002. All rights reserved.

Date:
File:

25.06.2006
PRO1_04E.25

SITRAIN Training for


Automation and Drives

Das könnte Ihnen auch gefallen