MultiParameterPatientMonitor
PRODUCTS
StandardParameter:ECG,NIBP,SpO2,Temp,Resp.
Fullyportabilitywithsteamlinehandle
Highbrightness12.1TFTcolorLCD
Bigfiguredisplay
ECGwaveformof7leaddisplayinonescreen
Compatibleandselfidentify3/5leadECGcable
NIBPdualoverpressureprotection
Isolatedfloating,antidefibrillationprotectedand
antihighfrequencyinterference
72hoursreviewtrend
480hoursreviewtrendwithexternalmemory
Optionalparameters&Configuration:
2IBP,EtCO2,2TEMP,Recorder,12leadECG,
CentralMonitoringnetworkS/W,WirelessNetwork,
VGAoutput,TouchLCD
Builtinrechargeablebattery
Dimension(mm):310(L)x140(W)x263(H)
Weight:3.8Kg
Selectionguide
RestingECG
CARDIPIA800H
CARDIPIA400H
CARDIPIA200
StressECGSystem
VeterinaryECG/Monitor
CARDIPIA400HV
CARDIPIA200
VITAPIA7000KV
HolterECG
ECGSimulator
PatientMonitor
TechnicalSpecifications
Classfication
VITAPIA7000K
Antielectrochocktype
Classlequipmentandinternalpoweredequipment
VITAPIA5000
EMCtype
ClassA
Antielectroshockdegree
ECG(RESP),SPO2,NIBP,IBP,TEMP,CO2 ,CF
VITAPIA5500
CMSS/W
FetalMonitor
FM8000Type8010
Specifications
SizeMonitor
310X140X263mm
WeightMonitor
3.8kg
Temperature
FM8000Type8007
Fetaldoppler
Humidity
DP6000
PulseOximeter
OXY500TypeFB/FBW
Altitude
Working
5~40
Transport/Storage
40~+55
Working
30%~75%
Transport/Storage
95%(nocoagulate)
Working
700hPa~1060hPa
Transport/Storage
500hPa~1060hPa
PowerSupply
OXY500TypeDP
100~240VAC,50/60Hz,Pmax=150VA,FUSET1.6A
Device
12.1in.colorTRT,3LED/800X600dots
TouchLCD(Option)
viewingangle(up:70,down:70,Left:50,Right:60andthebestangleis60)
Messages
8WaveformMaximum
1PowerLED(Green)
3SoungModecorrespondingAlarmMode
ECGOutput
BNC
Amplitude
1mV
Display
SignalInterface Accuracy
1AlarmLED(Yellow/Red)
1BatteryChargeLED(Yellow)
<5%
Impedance
50
SignalDelay
<20ms
Rechargeble3.7A/Hr7.4VLibattery
Operatingtimeunderthenormaluseandfullchargegreaterthan120min.
Operatingtimeafterthefirstalarmoflowbatterywillbeabout5min.
Battery
TrendRecall
Short:1hrs,1secondResolution
Long:72hrs,1minResolution
AlarmEventRecall
71alarmeventsofallparametersand8/16/32secondsofcorrespondingwaveform.
NIBPMeasurement
Recall
Atleast400NIBPmeasurementdata
SDcard
72hrsECGwaveform
480hrsTRENDreview
Leadmode
5Leads(R,L,F,N,CorRA,LA,LL,RL,V)
Leadselection
,,
Waveform
2CH
Leadmode
3Leads(R,L,ForRA,LA,LL)
Leadselection
,,
Waveform
1ch
Gain
x2.5mm/mV,x5.0mm/mV,x10mm/mV,x20mm/mV
HR
MeasuringRange:15~300bpm
AlarmRangle(ADU):15~300bpm
AlarmRange(PED/NEO):15~350bpm
Accuracy:1%or1bpm,whichgreat
Sensitivity:>200uVPP
Resolution:1bpm
Differentalinput
ECG
Impedance
>5M
Monitor:100dB
CMRR
Electodeoffset
potential
Operation:100dB
Diagnosis:60dB
300mV
LeakageCurrent
<10uA
BaselineRecovery
<5sAfterDefi
ECGSignalRange
8mV(Vpp)
Surgery:1~20Hz(+0.4dB,3dB)
Bandwidth
Monitor:0.5Hz~40Hz(+0.4dB,3dB)
Diagnostic:0.05Hz~75Hz(+0.4dB,3dB),76Hz~150Hz(+0.4dB,4.5dB)
CalibrationSignal
1mV(Vpp),5%Accuracy
STSegment
MonitoringRange
MeasureRange:0.6~+0.8mV
AlarmRange:2.0~+2.0mV
Type:ASYSTOLE,VFIB/VTC,COUPLET,BIGEMINY,TRIGEMINY,RONT,VT>2,PVC,
TACHY,BRADY,MISSEDBEATS,PNP,PNC
ARRDetecting
Alarm:Available
Review:Available
Method
ImpedancebetweenRF(RALL)
DifferentialInput
Impedance
>2.5M
Measuring
ImpedanceRange
RESPARATION
BaselineImpedance
Range
0.3~5.0
0.1~2.5K
Bandwidth
0.3~2.5Hz
Resp.Rate
MeasuringRange:0~120rpm
AlarmRange(PED/NEO):0~150rpm
Accuracy:2rpm
ApneaAlarm
10~40S
AlarmPage(ADU):0~120rpm
Resolution:1rpm
Oscillometric
Mode
Manual,Auto,STAT
Measuring
IntervalinAUTO
Mode
1,2,3,4,5,10,15,30,60,90,120,180,240,480,960min
Measuring
IntervalinSTAT
Mode
5min
AlarmType
SYS,DIA,MEAN
MeasuringandalarmRange
Adultmode
SYS:40~270mmHg
DIA:10~215mmHg
MEAN:20~235mmHg
Pediatricmode
SYS:40~200mmHg
DIA:10~150mmHg
MEAN:20~165mmHg
Neonatalmode
SYS:40~135mmHg
DIA:10~100mmHg
MEAN:20~110mmHg
Resolution
Pressure:1mmHg
Accuracy
Pressure(MaximumMeanerror):5mmHg
Pressure(MaximumStandarddeviation):8mmHg
Overpressure
protection
Adultmode:2973mmHg
Pediatricmode:2403mmHg
Neonatalmode:1473mmHg
NIEP
Measuring
Range
SpO2
0~100%
AlarmRange
0~100%
Resolution
1%
Accuracy
AlarmDelay
70~100%2%
0~69%unspecified
about1sec
Actualizationinterval 10sec
MeasuringandRange:0~250bpm
PulseRate
Resolution:1bpm
Accuracy:2bpm
Channel
Measuringand
AlarmRange
Resolution
TEMPERATURE Accuracy
Actualization
interval
AverageTime
Constant
0~50
0.1
0.2
about1sec
<10sec
Channel
Label
ART,PA,CVP,RAP,ICP,P1,P2
Measuring
range
Alarmrange
IBP(Option)
PressSensor
10~+300mmHg
50~+350mmHg
Sensitivity:5uV/V/mmHg
Impedance:300~3000
Resolution
1mmHg
Accracy
2%or1mmHgwhichgreat
Actualization
Interval
Method
Measuring
mode
about1sec
InfraredAbsorptionTechnique
MainstreamandSidestream
Sidestream
modesampling
50ml/Min.10ml/Min.
pasflowrate
CO2 :0~150mmHg
Measuringrange
INSCO2 :0~150mmHg
AwRR:2~150rpm
CO2
(Option)
Resolution
CO2 :0.1mmHg(0~69mmHg),0.25mmHg(70~150mmHg)
INSCO2 :0.1mmHg(0~69mmHg),0.25mmHg(70~150mmHg)
Accuracy
CO2:2mmHg,0~40mmHg
5%ofreading,41~70mmHg
8%ofreading,71~100mmHg
10%ofreading,101~150mmHg
AqRR:1rpm
Pacemaker
(Option)
Availalbe
Initialization
Time
Mainstrea:Capnogramdisplayedinlessthan15secatanambientTemp.of25,
fullsepcificationwithin2min
Sidestrea:Capnogramdisplayedinlessthan20secatanamblientTemp.of25,
fullsepcificationwithin2min
MainstreamRiseTime:Lessthen60msAdultReusableorSinglePatientUse
AirwayAdaptor
Sidestream
DelayTime
about1sec
Alarmrange
2~3sec
Suffocation
AlarmDelay
CO2 :0~150mmHg
Contentsandspecificationsubjectschangewithoutnotice