BSSPAR1: Chapter 1

Introduction to Parameter Planning

Nokia Siemens Networks

Legal Notice
Intellectual Property Rights
All copyrights and intellectual property rights for Nokia Siemens Networks training documentation, product documentation and
slide presentation material, all of which are forthwith known as Nokia Siemens Networks training material, are the exclusive
property of Nokia Siemens Networks . Nokia Siemens Networks owns the rights to copying, modification, translation, adaptation
or derivatives including any improvements or developments. Nokia Siemens Networks has the sole right to copy, distribute,
amend, modify, develop, license, sublicense, sell, transfer and assign the Nokia Siemens Networks training material.
Individuals can use the Nokia Siemens Networks training material for their own personal self-development only, those same
individuals cannot subsequently pass on that same Intellectual Property to others without the prior written agreement of Nokia
Siemens Networks .
The Nokia Siemens Networks training material cannot be used outside of an agreed Nokia Siemens Networks training session
for development of groups without the prior written agreement of Nokia Siemens Networks.

Nokia Siemens Networks

Module Objectives

At the end of the module, the participant will be able to:

Sketch a BSS Managed Object Hierarchy


Look up the parameters at each level, in the parameter dictionary
Identify parameter value ranges and default settings
Find the changes to objects and parameters, that occur with each
BSS software release

Nokia Siemens Networks

Managed Object (MO) Hierarchy


PLMN

BSC

DAP

BAL

MAL

MALD

LAPD

PCU

PCM

RA

BCF

BTS1
SEG
BTS2

TRX

ADCE

HOC

POC

ADJW

Nokia Siemens Networks

CH

Example from Parameter Dictionary


Parameter name

Rxlev Access Min

Abbreviated name

rxLevAccessMin

Managed object

BTS

Multiplicity

Description

With this parameter you define the minimum power level an MS has to receive before it is allowed to
access the cell.

Additional information

Range and step

-110...-47 dBm, step 1 dBm

Formula for getting internal value

internal_value = (gui_value + 110)

Default value

-105 dBm

Default value notes

Required on Creation

optional

Related functions

Modification

Online

Modified

Related parameters

Parameter relationships

Related options

Related features

Interfaces

References

RACApp <-> RAC


Planner <-> RAC
RAC <-> Optimizer
RAC <-> BSC
3GPP Reference: 44.018, 45.008

MML Commands

EQG, EQO

MML Abbreviated Name

RXP

MML Full Name

rxlev access min

Segment Level Parameter

true

File Based Provisioning supported

true

Nokia Siemens Networks

PRFILE, FIFILE and PAFILE parameters


PRFILE (General Parameter File)
Standard features
Optional features
Interrogate with MML command ZWOS

FIFILE (Feature Information Control File)


Stores optional parameters from the PRFILE
Interrogate with MML command ZWOI

PAFILE (BSC Control Parameter File)


GSM-BSC parameters
GSM Timers
Interrogate with MML command ZEGO

Nokia Siemens Networks

Features & Activation status

ZWOI command

ZWOS command
7

Nokia Siemens Networks

GSM-BSC Parameters & Timers

ZEGO command
8

Nokia Siemens Networks

Viewing parameters
Using NetAct CM Editor

Nokia Siemens Networks

Viewing parameters
with MML Commands in BSC
ZEQO Output

10

Nokia Siemens Networks

Exporting parameters
Using NetAct CM Ops Manager

11

Nokia Siemens Networks

New objects & parameters

12

Nokia Siemens Networks

Kygouygoliugli

Call Phases (MOC case)


MS

BTS

BSC

CH. REQUEST (RACH)


IMMEDIATE ASSIGN(AGCH)

Phase 1 : Paging, initial MS

SERVICE REQUEST (SDCCH)


AUTHENTICATION (SDCCH)
CIPHERING MODE (SDCCH)
TMSI REALLOCATION (SDCCH)

Phase 2 : MM signalling
Phase 8 : Ciphering
Phase 2 : MM signalling

SETUP (SDCCH)
ASSIGNMENT (SDCCH-FACCH)
CH.RELEASE
ALERTING & CONNECT
(FACCH)
CONN. ACK. and MEASUREMENT
DISCONNECT & RELEASE
(FACCH)

Phase 3 : Basic assignment


Phase 4 : Release
Phase 2 : MM signalling
Phase 15 : Conversation
Phase 4 : Release

Signalling procedures are used during the 15 phases in a basic call


Certain parameters influence the setting up and the release of a call
13

Nokia Siemens Networks

BSS13 Compatibility Information


The following entities are included within the Release BSS13:

BSCi, BSC2i, BSC3i - BSC S13


MetroSite BTS - CXM6.0
UltraSite BTS - CX6.0
Flexi EDGE BTS - EP2.0

The BSC S12 Release is the last compatible software level for the
Nokia 2nd Gen. & PrimeSite BTS products

The BSS13 is supported by the following Releases:

NetActTM - OSS4.2 CD Set 1 or OSS5.1


MSC - M14
Media Gateway U3C
SGSN - SG6 (with CD6)

BSS S13 does not support PBCCH/PCCCH and Background loading


of RN plan
14

Nokia Siemens Networks

Das könnte Ihnen auch gefallen