systemsASSEMBLY SCHEME OF THE STRUCTURE FORA
HORIZONTAL COLLECTOR 2.2\AND 2.
6.
Assembly scheme of the support structure
for a horizontal collector in flat surface
Assembly scheme of the
support structure on roof
‘The equipment must be installed in
place that won't receive shade from
any nearby objects
‘There is just a mounting scheme that
can be user for flat surface or roof.
Join pieces A, B, C, D, E and F
tightening bolts and muts firmly.
Drill holes in the concrete for the
sorews and their corresponding
plugs which allow fixing firmly the
structure to the chosen surface.
(C=1540 mm
D=930 mm
E5525 mm.
B= 815mm (26)| F=230 mm
Must assemble pieces D, F
‘and A and form a rectangle
Screw the rectangle firmly formed
by DFA fimly.
Join pieces C to pieces A. Check
all muts are fully tightened.
Onoot, B land F angles are
not used:ASSzWehy Sets atelanne eon llonnel sta
ONE VERTICAL COLLECTOR
Assembly scheme of the support
structure on flat surface
The equipment must be installed in
place that won't receive shade from
any nearby objects.
‘There is just a mounting scheme that
‘can be used flat surface or on roof.
\ Join pieces for A, B, C, D, E and F
\ \ tightening bolts and nust firmly.
Diill holes in the concrete for the
‘screws and their corresponding plugs
Which allow fixing firmly the structure
to the chosen surface.
Assembly scheme of the
support siraclunser ea
Assemble pieces B, F and A and
form a rectangle
‘Screwithe rectangle formed
by 8, F and firmly
Join pieces C to pisces A.
Check all nuts are fully tightened.
Oh root, D and’ angles
fare not usedASSEMBLY SCHEME OF Wid EsSug Ab iosab iets
FOR TWO VERTICAL COLBECGHh@RS)
Assembly scheme of the support ‘The equipment must be installed in
Jace that won't Shade fro
structure on flat surface eM ees
There is just a mounting scheme that
can be used flat surface or on roof
Join pieces for A, 8, C, D, E and F
tightening bolts and nuts firmly.
Drill holes in the concrete for the
screws and their corresponding
plugs which allow fixing firmly the
structure to the chosen surface.
‘A=2100 mm
100 mm
(C=2005 mm
Assembly scheme of the suppo
structure onroof
- Oa
Assemble pieces 8, F and A and
form a rectangle.
‘Sctew the rectangle formed
by B,F and A firmly.
doin pieces C to pieces A. Check
all nuts are fully tightened
On roof, Dandie angle’,
arénotused,Psst SYA SCHEME OF THE STRU!
COLL
FOR TINS SV Sager yates
Assembly scheme of the support
structure on flat surface
Assembly scheme of the support
structure on roof
‘The equipment must be installed in
place that won't receive shade from
any nearby objects.
‘There is just a mounting scheme that
can be used flat surface or on roof.
Join pieces for A, B, C, D, E and F
tightening bolts and nuts firmly.
Diill holes in the concrete for the
screws and their corresponding plugs
which allow fixing firmly the structure
to the chosen surface. The structure
must be leveled.
‘Assemble pieces D, F and A
‘and form a rectangle.
Screw the rectangle formed
by D, and firmly:
Join pieces C to pieces A. Check
all nutss are fully tightened,
On roof, B) and\E angles
are'not used.Air vent and
sensor pocket Solar collectors
Collectors
input
Solar cofttroller
in the equipment
Expansion
_ vessel
Coll output flange inspection
Safety and check x
valve 8 bar. ——|Hydraulic Kit:
Connect all the components as spe-
cified on the previous page.
The safcty expansion vessel con-
nection with the security valve of the
hydraulic kit must not be longer than 2
meters, non folded and witmou points
of air accumulation. Diameter must be
of 3/4” It is recommended to use the
provided hose.
After the hydraulic installation, the
closed circuit has to be cleaned. ‘The
cleaning of the circuit is done with
water, if last 15 minutes and it is done
isolating the pump with the two valves
which are before and after it, leaving
open the two filling and emptying keys
and closing the flowmeter. |
‘Before the system starts it is necessary
to check the tightness of all connes-
tions.
5 Io es itis epee
a key, (filling or e
Cleaning and using the water pressure
pump from the net, increase -
sure to.5 bar for about 15 minutes.
The mixture of antifteeze with water is
done before the filling, according to the
minimum possible tgmperature of the
installation place. _ oa
It is the installer’ lity to use
the right quantity of propilenglicol!
The filling of the system-is done
from the pump station using a pump.
The working pressure between 3-and 4
Assembly instructions
‘To minimize the thermal loses, itis
necessary to choose, when designing
the installation, the tinimum distance
among the collectors and the solar
exchanger of the tank.
Itis necessary t0 avoid the creation
of ait accumulation, points. Otherwise
‘you always have to inelude an automa-
tic purge in each of these points.
‘The tbe diameter recommended is
18mm for distances up to 20:m and 15
mm for distances up to 12m.
All the additional connection ac
cessorics used must resist a 6 bar
sure and temperatures between
to 150°C
10°C
ORMATION
Nig
THE USER
SS
Inven8 of halfnction oF the
system fore contacting the
‘aller, distributor, manager or manu
facturer, we advise you to have availa
bar is obtained with the pressure pamp-Ple the following information.
at
or the pressure from the net. Durin,
filling do not forget to check.
urge points:
Pipes of the closed circuit:
The go and retum tubes from and
to the collectors have to be well isula-
ted in a way that is temperature resi-
stant betwein -30°C to + 150.
It is mandatoty an UV protection
for the chosen insulation for all outdoor
areas.
The insulation material thickness
rust be selected according to the cur-
rent regulation,
Client instructions: advices:
+ In_ solar systems, it_ is not
necessary the user intervention. Ho-
‘wever, we recommend after the first 15
working days, to check the closed cir-
cuit pressure’ (collector-accunmulator)
and temperatures are in normal leveles,
regarding the control time, the insulati-
on and the “Installation sheet”
+ Request your installer the change
‘of magnesium anode every 2 years.
+ It is recommended to clean the
glass collector regularly in low rainfall
areas.
Once finished the installation,
the installer must inform to the client
about the working of the system,
In case of system malfunction, it is
adviced to contact your installer in the
first place, since he knows all the in
stallation parameters.
In case of malfunction (instruc-
tions to the installer)
Please make sure that:
+ Weather conditions let-the-wor-
king of the system
* Collectorswafé not shaded and
glasses are eleane are no leaks.
There is not leaking in the closed
“elrcuit, and all the connections are well
insulated
+ The controller. parameters are
comect,
= The pump works when the we-
ather conditions require it Touching
the pump it is possible to feel the
system vibrations. Check the electrici-
ty grid and if it is necessary contact an
al od installer.
__* Mixing valve is well regulated
and works eee
* The close circuit pressure check
the manometer in the hydraulic assem-
bly) is the same as the written in “in-
stallation sheet”(3-4 bar) For the im-
mediate working ofthe system, fill the
close circuit with the mixture of water
and antifreeze or adjust the automatic
filling key until reach the indicated
pressure in the “Installation sheet”
+ There is enough liquid in the col-
lector-accumulator’s circuit, During
days with much insolation and normal
‘working of the pumip, pipes in their
higher points collector outlets) should
ec hot.
+ There is no air im the expansion
vessel and the safety valve i not lea-
ing,Your installer: