Beruflich Dokumente
Kultur Dokumente
www.rosenberger.com
www.rosenbergerap.com
INTRODUCTION
Rosenberger Hochfrequenztechnik GmbH&Co. was founded in Germany in 1958 and ranks among the leading manufacturers
of high-speed interconnect solutions worldwide. To serve the continuous growth and demand of the global market, Rosenberger
Asia Pacific Electronic Co., Ltd. was established in China in 1997. With its long tradition of excellence and providing creative
solutions, Rosenberger Asia Pacific has excelled and earned an outstanding reputation in the Asia Pacific region.
Rosenberger Asia Pacific provides products and solutions for Telecommunication, Automotive Electronics, Information
Technology, Test & Measurement, Aviation, and Medical & Industries.
A sales network covering the entire Asia Pacific region generates an annual turnover close to 300 million USD. Reliability and
competitiveness are the cornerstones of this sustainable growth, resulting in long term partnerships with most of the leading
companies in their respective industries.
E
Rosenberger Asia Pacific:
A: Beijing, China Headquarters, R&D and Production
B: GOA, India R&D and Production
C: Guangdong Dongguan, China R&D and Production
D: Haryana, India R&D and Production
Rosenberger Asia Pacific maintains 6 modern manufacturing and R&D base locations in Beijing, Shanghai, Kunshan and
Dongguan in China as well as Haryana & GOA in India, the largest of its kind in the Asia Pacific Region. Rosenberger Asia
Pacific is an ISO 9001 quality system, ISO 14001 environmental system, and ISO/TS 16949 automotive industry system certified
company. Equipped with advanced machining, electronic plating, cable manufacturing, assembly and testing centers and staffed
with more then 200 R&D engineers, Rosenberger Asia Pacific has developed the first class production assembly lines and
exercises stringent product and quality control.
Presently, Rosenberger Asia Pacific maintains a far reaching network of R&D, Production, Sales and Service which extends
to the whole Asia Pacific and Middle East region. For over 55 years Rosenberger has established its brand and reputation all
over the world. Moving forward, Rosenberger Asia Pacific will continue to provide excellent product solutions and services for its
customers in the entire region.
MISSION STATEMENT
Design, manufacture and deploy total solutions for telecommunication networks worldwide
Create value for our customers through innovative products, customized services and cost effective solutions
Maintain the highest quality standards, state-of-the-art manufacturing facilities and employ reliable supply chain
management to achieve and exceed customer expectations
Be socially responsible to our community and environment
Be committed to employee's personnel development
Core Value
Value Innovation
Customer Focus
Sustainable Growth
Social Responsibility
PRODUCT
PORTFOLIOS
Telecommunication
System Solutions
IT/Data Communication
RF Test Cables
RF Precision Connectors
Calibration Kits
Accessories and Tools
Automotive Electronics
HSD System
HVR High Voltage Connectors
RoPD Power Data Connectors
Non-Magnetic RF Connectors
Non-Magnetic RF Cable Assemblies
+
1991-2014
Superior Quality
The quality of our products and services is an essential part of our corporate strategy. Rosenbergers quality
philosophy is not just to optimize components and products, but to continuously improve and optimize all processes to
ensure customer satisfaction: from product development, planning, purchasing, production, sales, logistics and service to
environmental policy all in all, to offer maximum benefit to our customers all over the world.
Responsibility for quality also means being proactive in protecting our environment and natural resources. We endeavour to avoid or
minimize environmental pollution even beyond the requirements of legal regulations whenever possible.
Rosenberger is certified according to ISO/TS 16949, ISO 9001 and ISO 14001
Environmental Directives
Connectors and cable assemblies manufactured by Rosenberger correspond to the following Directives:
2011/65/EU - Restriction of the use of certain Hazardous Substances in electrical and electronic equipment (RoHS)
2012/19/EU - Waste Electrical and Electronic Equipment (WEEE)
The objective of the above mentioned European Directives is to avoid or to limit the use of the following hazardous substances:
Lead
Mercury
Cadmium
Chrome VI
PBB (Polybrominated Biphenyls)
PBDE (Polybrominated Diphenyl Ethers)
Content
Introduction................................................ 2
Discrete FTTA Solution............................ 10
FTTA Cable Assembly E Series........................................... 11
Balun Panel......................................................................... 63
LC Trunk Solution................................................................ 22
TM
EasyLink
TM
LC Loopback Connector...................................................... 79
LC Connector...................................................................... 80
SC Connector...................................................................... 81
MU Connector..................................................................... 82
RRH Jumper............................................ 35
RDC Fiber Jumper.............................................................. 36
RQC Fiber Jumper ............................................................. 37
E2000TM Connector............................................................. 83
Rosenberger Fiber Enclosure (RFE)................................... 84
Hybrid Jumper..................................................................... 39
Distribution Box....................................... 41
Buffered Fiber...................................................................... 90
Installation Accessory.............................. 45
Cable Clamp........................................................................ 46
Grounding Kits..................................................................... 47
Hoisting Grips...................................................................... 47
10
Description
This FTTA cable assembly is designed for connecting the Main Unit (MU) and the E Series of Radio Remote Head (RRH).
Plug-and-play installation
Armored cable for monkey-bite and anti-rodent protection
UL(OFNR) and Anatel certified cable available on request
Customized cable and cable assembly available on request
Specification
Profile/Outline
Type A
Side B
B A
B A
Side A
Type B
Side A
Side B
Type C
Side A
Side B
B A
B A
Type D
Side A
Side B
B A
Type E
Side A
Side B
B A
11
Type F
Side A
Side B
Type G
Side A
Side B
B A
Type B
Type C
Type D
Type E
Type F
Type G
Connector
Side A
LCD, SM
LCD, SM
Side B
LCD, SM
LCD, SM
2 fibers
4.8mm
2 fibers
4.8mm
No
No
20mm
20mm
60mm
20mm
20mm
20mm
20mm
30mm
30mm
100mm
30mm
30mm
30mm
30mm
300N
300N
300N
300N
300N
300N
300N
450N
450N
400N
450N
450N
450N
450N
3000N/10cm
3000N/10cm
Cursh Resistance
Flame Resistance
LCD, SM
2000N/10cm
3000N/10cm 7000N/10cm 7000N/10cm
IEC 60332-1, IEC 60332-3-24, UL 1666 (optional)
LCD, SM
Yes
Yes
Yes
Yes
Yes
-40 C to +80 C
-40 C to +80 C
-20 C to +60 C
Compliant
12
2 fibers
4.8mm
YES
7000N/10cm
Environmental Data
L 100 m
L >100 m
LCD, SM
1 pc in a bag
1 pc on cardboard/wooden drum
Yes
Yes
Description
This FTTA cable assembly is designed for connecting the Main Unit (MU) and the H Series of Radio Remote Head (RRH).
Specification
Profile/Outline
Type A
Side A
Side B
1A
2A
1B
2B
Type B
Side B
Side A
2A
1A
1B
2B
Type C
Side A
Side B
1A
1B
0A
0A
0B
0B
1A
1B
13
Type D
Side B
Side A
0A
0B
1A
1B
1A
1B
Type B
Type C
Type D
Connector
Side A
LCD
LCD
2*LCD
2*LCD
Side B
LCD
2*FC
2*LCD
4*FC
Side A
Yes
Yes
Yes
Yes
Side B
Yes
No
Yes
No
Fiber Count
2 fibers
2 fibers
Cable Diameter
7.0mm
7.0mm
Jacket Material
Armor Protection
Min. Bending Radius
(Static)
Min. Bending Radius
(Dynamic)
Max. Tension Strength
(Long-Term)
Max. Tension Strength
(Short-Term)
Crush Resistance
4 fibers
7.0mm
7.0mm
LSZH
No
No
No
No
70mm
70mm
70mm
70mm
140mm
140mm
140mm
140mm
200N
200N
200N
200N
400N
400N
400N
400N
2200N/10cm
2200N/10cm
2200N/10cm
2200N/10cm
Flame Resistance
Smoke and Halogen
Emission
UV Resistance
4 fibers
Yes
Yes
Environmental Data
Temperature Range Operation
-40 C to +80 C
-40 C to +80 C
-20 C to +60 C
2011/65/EU(RoHS)
Compliant
14
L 40 m
1 pc in a bag
L >40 m
1 pc on cardboard/wooden drum
Yes
Description
This FTTA cable assembly is designed for connecting the Main Unit (MU) and the N Series of Radio Remote Head (RRH).
Specification
Profile/Outline
Type A
Side B
Side A
Type B
Side A
Side B
Type C
Side B
Side A
B
A
15
Type D
B
Side B
B
Side A
A
Type E
Side A
Side B
Type B
Type C
Type D
Type E
Side A
LC SM(90)
LC SM(Flex)
LCD SM(90)
LCD SM(Flex)
LCD SM
Side B
LC SM(90)
LC SM(Flex)
LCD SM
LCD SM(Flex)
LCD SM
Fiber Type
G652D/G657A
G657A2
G657A2
G657A2
G652D
Fiber Count
1 fiber
1 fiber
2 fibers
2 fibers
4 fibers
Cable Diameter
5.0mm
5.0mm
5.0mm
5.0mm
5.2mm
Jacket Material
PVC
PVC
PVC
PVC
LSZH
Connector
No
No
No
No
No
Armor Protection
50mm
50mm
50mm
50mm
50mm
75mm
75mm
75mm
75mm
75mm
600N
600N
600N
600N
600N
1200N
1200N
1200N
1200N
1200N
7500N/10cm
7500N/10cm
7500N/10cm
7500N/10cm
7500N/10cm
Cursh Resistance
Flame Resistance
Yes
Yes
Yes
Environmental Data
Temperature Range Operation
-40 C to +80 C
-40 C to +80 C
-20 C to +60 C
2011/65/EU(RoHS)
Compliant
16
L 100 m
1 pc in a bag
L >100 m
1 pc on cardboard drum
Yes
Description
This FTTA cable assembly is designed for connecting the Main Unit (MU) and the S Series of Radio Remote Head (RRH).
Plug-and-play installation
UL(OFNR) certified cable available on request
Customized cable and cable assembly available on request
Specification
Profile/Outline
Type A
Grounding kit
Side B
Side A
RX
RX
DU
RU
TX
Type B
TX
Grounding Kit
Side A
A
Side B
DU
TX
RX
Type C
Side B
A
Side A
DU
TX
RX
17
Type B
Type C
Side A
2*LC, SM
LCD(c/w PDLC03J-02) SM
LCD(c/w PDLC03J-01) SM
Side B
2*LC, SM
2*LC, SM
2*LC, SM
Fiber Type
G652D
G657B3
G657B3
Connector
2 fibers
2 fibers
2 fibers
Cable Diameter
4.8mm
4.8mm
6.3mm
Jacket Material
LSZH
LSZH
LSZH
Yes
Yes
NO
Armor Protection
Min. Bending Radius (Static)
50mm
50mm
60mm
100mm
100mm
120mm
300N
300N
600N
450N
450N
1500N
7000N/10cm
7000N/10cm
3000N/10cm
Cursh Resistance
Flame Resistance
Yes
Environmental Data
Temperature Range Operation
-40 C to +80 C
-40 C to +80 C
-20 C to +60 C
2011/65/EU(RoHS)
Compliant
18
L 100 m
1 pc in a bag
L >100 m
1 pc on cardboard drum
Yes
19
Description
2-fiber RDC (Rosenberger Duplex Connector) trunk is an innovative
solution with multi-fibers in a single cable to simply the RRH
deployments. The trunk is designed with slim dividers which split
multi-fibers into individual outdoor cables. The trunk cables are
terminated with IP67-rated RDC connectors. Different types of
jumpers are available to allow connection between the trunk cable
Specification
Profile/Outline
12 fibers RDC - LCD
LengthTolerance
Key
B A
A-A
Key
B A
A-A
Trunk Cable
Side A (Top)
Side B (Bottom)
Breakout Cable Length
Cable Retention Force (Fiber Breakout)
Cable Retention Force (Trunk Cable)
Cable Bending Radius Min. (Installation)
Cable Bending Radius Min. (Operation)
Outer Diameter Nominal
Jacket Material
Fiber Type
Flammability
2011/65/EU(RoHS)
Temperature Range
Packing
20
12 fibers
6*RDC
24 fibers
12*RDC
6*LC duplex
12*LC duplex
600mm, 700mm, 800mm
200N
1000N
10 times the cable diameter
20 times the cable diameter
6.2 0.3mm
8.5 0.5mm
LSZH
G657A, OM2, OM3
IEC 60332-1
Compliant
-40C ~ +70C
Wood board drum
Description
4-fiber RQC (Rosenberger Quad Connector) trunk is an innovative
solution with multi-fibers in a single cable to simply the RRH
deployments. The trunk is designed with slim dividers which split
multi-fibers into individual outdoor cables. The trunk cables are
terminated with IP67-rated RQC connectors. Different types of
jumpers are available to allow connection between the trunk cable
Specification
Profile/Outline
12 fibers RQC - LCD
LengthTolerance
key
B A
A
2B 2A 1B 1A
key
B A
A
2B 2A 1B 1A
Trunk cable
Side A (Top)
Side B (Bottom)
Breakout Cable Length
Cable Retention Force (Fiber Breakout)
Cable Retention Force (Trunk Cable)
Cable Bending Radius Min. (Installation)
Cable Bending Radius Min. (Operation)
Outer Diameter Nominal
Jacket Material
Fiber Type
Flammability
2011/65/EU(RoHS)
Temperature Range
Packing
12 fibers
3*RQC
6*LC duplex
24 fibers
6*RQC
12*LC duplex
600mm, 700mm, 800mm
200N
1000N
10 times the cable diameter
20 times the cable diameter
6.2 0.3mm
8.5 0.5mm
LSZH
G657A, OM2, OM3
IEC 60332-1
Compliant
-40C ~ +70C
Wood board drum
21
LC Trunk Solution
Description
Traditional trunk solution is a typical design using a LC connector
terminated trunk cable and distribution box. The cable runs from
the BBU up to a weatherproof distribution box at the tower top.
The distribution box provides the interconnection point for fibers
between the trunk cable and the jumpers leading to the RRHs.
Trunk Solution is the good choice for operators who lease space
on tower cell sites. It reduces annual leasing costs by reducing the
space utilized on the tower. Plug-and-Play connections minimize
installation time and require no tools.
Specification
Profile/Outline
12 fibers LCD - LCD
B A
B A
LengthTolerance
B A
B A
LengthTolerance
Trunk cable
12 fibers
24 fibers
Side A (Top)
6*LC duplex
12*LC duplex
Side B (Bottom)
6*LC duplex
200N
1000N
10 times the cable diameter
22
12*LC duplex
600mm, 700mm, 800mm
6.2 0.3mm
8.5 0.5mm
LSZH
G657A, OM2, OM3
IEC 60332-1
2011/65/EU(RoHS)
Compliant
Temperature Range
Packing
-40C ~ +85C
Wood board drum
23
Description
EasyLink TM RDC (2-fiber Rosenberger Duplex Connector)
terminated hybrid cable is an innovative solution to combine
optical fibers and DC power lines in a single cable to simply the
RRH deployments. The EasyLinkTM hybrid system is designed with
slim dividers which split multi-fiber and DC cables into individual
outdoor cables. The hybrid trunk cables are terminated with IP67rated RDC connectors. Different types of jumpers are available
to allow connection between the hybrid cable and any vendorspecific hardware interface.
EasyLink TM Hybrid Solution is the best choice for operators
who lease space on tower cell sites. It reduces annual leasing
costs by reducing the space utilized on the tower. Plug-and-Play
connections minimize installation time and require no tools.
24
Plug-and-play installation
Reduced tower loading and leasing costs
Terminated with RDC on top breakout to connect with RRHs by
matching RDC fiber jumpers
Easy adjustment of length of bottom breakout point
Profile/Outline
3X3 (Top side 3 power connectors and 3 RDC)
LengthTolerance
B A
B A
B A
B A
B A
LengthTolerance
B A
B A
B A
B A
B A
LengthTolerance
B A
B A
B A
B A
B A
25
Hybrid Trunk
Number of RRH
3 RRH
Structure
6 RRH
3X3, 3X6
6X6
RDC (Rosenberger Duplex Connector)
DC power Connector or open ended
LC duplex
open ended
Aluminum
Min. 63mm
Min. 80mm
180mm
220mm
600mm, 700mm, 800mm
500mm
1500mm
1500mm
200N
500N
1000N
10 times the cable diameter
20 times the cable diameter
-40C ~ +70C
Wood board drum
Fiber
Power
Fiber
Side B (Bottom)
Power
Material
Divider
Diameter
Height
Fiber
Breakout Cable Length (Top)*
Power
Fiber
Breakout Cable Length
(Bottom)*
Power
Fiber Breakout
Cable Retention Force (Divider) Power Breakout
Hybrid Trunk
Installation
Cable Bending Radius Min.
Operation
Temperature Range
Packing
Side A (Top)
Hybrid Cable
Number of RRH
Number of Copper Conductor
Number of Fiber
Conductor Size
3 RRH
6 (3 pairs)
6~12
4mm2 (12AWG), 6mm2 (10AWG), 10mm2
27.5 0.5mm (4mm2)
27.5 0.5mm (6mm2)
27.5 0.5mm (10mm2)
6 RRH
12 (6 pairs)
12
(8AWG)
27.5 0.5mm (4mm2)
27.5 0.5mm (6mm2)
32 0.8mm (10mm2)
FRPE, UV resistance
Corrugated aluminum
Copper tape
Singlemode: G652D, G657A
Mulitmode: OM1, OM2, OM3, OM4
Uo/U 600/1000V
IEC 60332-1, IEC 60754-2, IEC 61034-2
Compliant
Fiber Type
Nominal Voltage
Flammability
2011/65/EU(RoHS)
Ordering Information
EasyLinkTM RDC
Hybrid Series
L98Y-C0001-XXX
Number of RRH
Number of fiber
Number of power
conductor
6
L98Y-C0002-XXX
L98Y-C0003-XXX
10
12
12
L98Y-C0027-XXX
12
10
L98Y-C0103-XXX
12
12
L98Y-C0104-XXX
12
12
L98Y-C0105-XXX
12
12
10
L98Y-C0004-XXX
L98Y-C0005-XXX
L98Y-C0006-XXX
10
12
12
L98Y-C0030-XXX
12
10
L98Y-C0106-XXX
12
12
L98Y-C0107-XXX
12
12
L98Y-C0108-XXX
12
12
10
Fiber type
L98Y-C0025-XXX
L98Y-C0026-XXX
G657A
L98Y-C0028-XXX
L98Y-C0029-XXX
26
OM2
Power
conductor(mm2)
4
Description
EasyLinkTM RQC ( 4-fiber Rosenberger Quad Connector ) terminated
hybrid cable is an innovative solution to combine optical fibers and
DC power lines in a single cable to simply the RRH deployments.
The EasyLinkTM hybrid system is designed with slim dividers
which split multi-fiber and DC cables into individual outdoor
cables. The hybrid trunk cables are terminated with IP67-rated
RQC connectors. Different types of jumpers are available to allow
Support up to 9 RRH
IP67 robust and compact divider
IP67 RQC and power connectors for water immersion and dust protection
Corrugated aluminum or copper tape armored design
Plug-and-play installation
Reduced tower loading and leasing costs
Terminated with RQC on top breakout to connect with RRH by matching RQC fiber jumpers
Easy adjustment of length of bottom breakout point
27
Specification
Profile/Outline
3X6 (Top side 3 power connectors and 3 RQC)
LengthTolerance
B A
B A
B A
B A
B A
B A
B A
B A
B A
B A
B A
B A
B A
LengthTolerance
B A
B A
B A
B A
B A
LengthTolerance
28
Hybrid Trunk
3 RRH
Number of RRH
Structure
6 RRH
9 RRH
3X6
Side A (Top)
Side B (Bottom)
Divider
Breakout Cable Length (Top)*
Breakout Cable Length (Bottom)*
Cable Retention Force (Divider)
Cable Bending Radius Min.
6X12
9X18
RQC (Rosenberger Quad Connector)
DC power Connector or open ended
LC duplex
MTP
open ended
Aluminum
Min. 63mm
Min. 80mm
Min. 80mm
180mm
220mm
220mm
600mm, 700mm, 800mm
500mm
1500mm
1500mm
200N
500N
1000N
10 times the cable diameter
20 times the cable diameter
-40C ~ +70C
Wood board drum
Fiber
Power
Fiber
Power
Material
Diameter
Height
Fiber
Power
Fiber
Power
Fiber Breakout
Power Breakout
Hybrid Trunk
Installation
Operation
Temperature Range
Packing
*customized lengths available
Hybrid Cable
3 RRH
6 (3 pairs)
12
6 RRH
9 RRH
12 (6 pairs)
18 (9 pairs)
24
36
4mm2 (12AWG), 6mm2 (10AWG), 10mm2 (8AWG)
27.5 0.5mm (4mm2)
32 0.8mm (4mm2)
27.5 0.5mm (4mm2)
27.5 0.5mm (6mm2)
27.5 0.5mm (6mm2)
32 0.8mm (6mm2)
2
2
27.5 0.5mm (10mm )
32 0.8mm (10mm )
36 0.8mm (10mm2)
FRPE, UV resistance
Corrugated aluminum
Copper tape
Copper tape
Singlemode: G652D, G657A
Mulitmode: OM1, OM2, OM3, OM4
4mm2 (12AWG), 6mm2 (10AWG), 10mm2 (8AWG)
Uo/U 600/1000V
IEC 60332-1, IEC 60754-2, IEC 61034-2
Compliant
Number of RRU
Number of Copper Conductor
Number of Fiber
Conductor Size
Outer Diameter Nominal
Jacket Material
Armored Type
Fiber Type
Conductor Size
Nominal Voltage
Flammability
2011/65/EU(RoHS)
Ordering Information
EasyLinkTM RQC
Hybrid Series
L98Y-C0109-XXX
L98Y-C0110-XXX
L98Y-C0111-XXX
L98Y-C0115-XXX
L98Y-C0116-XXX
L98Y-C0117-XXX
L98Y-C0121-XXX
L98Y-C0122-XXX
L98Y-C0123-XXX
L98Y-C0112-XXX
L98Y-C0113-XXX
L98Y-C0114-XXX
L98Y-C0118-XXX
L98Y-C0119-XXX
L98Y-C0120-XXX
L98Y-C0124-XXX
L98Y-C0125-XXX
L98Y-C0126-XXX
Fiber type
G657A
OM2
Number of RRH
Number of fiber
3
3
3
6
6
6
9
9
9
3
3
3
6
6
6
9
9
9
12
12
12
24
24
24
36
36
36
12
12
12
24
24
24
36
36
36
*XXX represents length (mm). E.g. L98Y-C0109-20000 means trunk length 20m
Number of power
conductor
6
6
6
12
12
12
36
36
36
6
6
6
12
12
12
36
36
36
Power
conductor(mm2)
4
6
10
4
6
10
4
6
10
4
6
10
4
6
10
4
6
10
29
Description
EasyLinkTM RMCTM (Rosenberger Multi-fiber Connector) terminated
hybrid cable is an innovative solution to combine optical fibers and
DC power lines in a single cable to simply the RRH deployments.
The EasyLink TM hybrid system is designed with slim dividers
which split multi-fiber and DC cables into individual outdoor
cables. RMCTM adopt standard MPO fiber interface with additional
protection to work under harsh environments which particularly
applicable for 6 RRH and 9 RRH solution. The hybrid trunk cables
30
Specification
Profile/Outline
6X12 ( Top side 6 power connectors and 3 RMCTM )
LengthTolerance
LengthTolerance
B A
B A
B A
B A
B A
31
Hybrid Trunk
Number of RRU
6 RRH
Structure
6X12
9X18
RMCTM 8 fibers
RMCTM 12 fibers
Fiber
Side A (Top)
Power
Fiber
Side B (Bottom)
9 RRH
LCD
MTP 12 fibers
Power
Open ended
Material
Divider
Aluminium
Diameter
Min. 63mm
Min. 80mm
180mm
220mm
Height
Breakout Cable Length (Top)*
Breakout Cable Length
(Bottom)*
Fiber
Power
500mm
Fiber
1500mm
Power
1500mm
Fiber Breakout
Cable Retention Force (Divider)
200N
Power Breakout
500N
Hybrid Trunk
1000N
Installation
Operation
Temperature Range
Packing
*customized lengths available
Hybrid Cable
Number of RRU
Number of Copper Conductor
Number of Fiber
Conductor Size
6 RRH
9 RRH
6 (3 pairs)
18 ( 9 pairs)
24
36
4mm2 (12AWG), 6mm2 (10AWG), 10mm2 (8AWG)
32 0.8mm ( 4mm2)
27.5 0.5mm (4mm2)
2
27.5 0.5mm (6mm )
32 0.8mm ( 6mm2)
32 0.8mm (10mm2)
36 0.8mm (10mm2)
FRPE, UV resistance
Copper tape
Copper tape
Singlemode: G652D, G657A
Mulitmode: OM1, OM2, OM3, OM4
Uo/U 600/1000V
IEC 60332-1, IEC 60754-2, IEC 61034-2
Compliant
Ordering Information
RMCTM Hybrid Series Fiber type
Number of RRH
Number of fiber
Power conductor(mm2)
L98Y-C0127-XXX
24
12
L98Y-C0128-XXX
24
12
24
12
10
36
36
L98Y-C0134-XXX
36
36
L98Y-C0135-XXX
36
36
10
L98Y-C0130-XXX
24
12
L98Y-C0131-XXX
24
12
24
12
10
36
36
L98Y-C0137-XXX
36
36
L98Y-C0138-XXX
36
36
10
L98Y-C0129-XXX
L98Y-C0133-XXX
L98Y-C0132-XXX
L98Y-C0136-XXX
G657A
OM2
*XXX represents length (mm). E.g. L98Y-C0127-20000 means trunk length 20m
32
Description
Traditional Hybrid Solution is a typical design using a LC connector
terminated hybrid cable and distribution box. The cable runs from
the BBU up to a weatherproof distribution box at the tower top.
The distribution box provides the interconnection point for power
and fiber between the hybrid cable and the jumpers leading to the
RRH. The Distribution box can include over-voltage protection
33
Specification
Hybrid Trunk
Side A (Top)
Side B (Bottom)
Breakout Cable Length (Top)*
Breakout Cable Length (Bottom)*
Cable Bending Radius Min.
Fiber
LC duplex
Power
Open ended
Fiber
LC duplex
Power
Open ended
Fiber
Power
500mm
Fiber
4m
Power
4m
Installation
Operation
Temperature Range
-40C ~ +70C
Packing
Trunk Cable
Number of RRH
Number of Copper Conductor
Number of Fiber
Conductor Size
4 RRH
8 (4 pairs)
Up to 16
4mm2 (12AWG), 6mm2 (10AWG), 10mm2 (8AWG)
27.5 0.5mm (4mm2)
27.5 0.5mm (6mm2)
27.5 0.5mm (10mm2)
FRPE, UV resistance
Corrugated aluminum
Singlemode: G652D, G657A
Mulitmode: OM1, OM2, OM3, OM4
Uo/U 600/1000V
IEC 60332-1, IEC 60754-2, IEC 61034-2
Compliant
Ordering Information
LC Hybrid Series
L98Y-C0081-XXX
L98Y-C0082-XXX
L98Y-C0083-XXX
L98Y-C0084-XXX
L98Y-C0085-XXX
L98Y-C0086-XXX
Fiber type
G657A
OM2
Number of RRH
Number of fiber
4
4
4
4
4
4
12
12
12
12
12
12
*XXX represents length (mm). E.g. L98Y-C0127-20000 means trunk length 20m
34
Number of
power conductor
6
6
6
6
6
6
Power
conductor (mm2)
4
6
10
4
6
10
RRH Jumper
Rosenberger provides standard and customized RRH jumpers for connection between Rosenberger FTTA trunk
cable assemblies or Rosenberger FTTA hybrid cable assemblies and remote radio heads (RRHs). RRH jumper
provides installation and upgrade flexibility for different cellular site scenarios. Fiber optic jumper, power jumper
as well as hybrid jumper are available from Rosenberger with 100% factory assembled and tested, and are compatible with all types of system vendor equipment interfaces. Particularly the Rosenberger RDC, RQC and RMCTM
terminated fiber jumpers provide IP67-rated direct connection without extra distribution box required, which significantly ease the installation and reduce labor costs.
35
Description
The RDC (2-fiber Rosenberger Duplex Connector) fiber jumper
can directly connect RRHs and EasyLinkTM hybrid trunk cable
assembly or FTTA trunk cable assembly. Terminated with
Specification
Profile/Outline
Side B
Side A
Side B Side A
Side B
B A
Side A
0.5dB
0.3dB
50dB
50dB
4.8mm
Singlemode: G652D, G657A
Mulitmode: OM1, OM2, OM3, OM4
50mm
30mm
450N
300N
3KN/100mm
-40C ~ +80C
-40C ~ +80C
-20C ~ +65C
Compliant
RDC
LC
RDC
LC
Installation
Operation
Installation
Operation
Operation
Storage
Installation
Temperature Range
2011/65/EU (RoHS)
* Other cable size options are available upon request.
Ordering Information
RDC Jumper Series
L98B-893-XXX
L98B-894-XXX
L98B-895-XXX
L98C-853-XXX
L98C-854-XXX
L98C-855-XXX
Fiber Type
G657A
OM2
Number of Fiber
2
2
2
2
2
2
Top Connector
LCD with RFE
LCD
LCD with IP seal
LCD with RFE
LCD
LCD with IP seal
Bottom Connector
RDC
RDC
RDC
RDC
RDC
RDC
*XXX represent length (mm) from end to end. E.g. L98B-893-XXX means jumper length 5m.
36
Ericsson
Huawei
Nokia
Ericsson
Huawei
Nokia
Description
The RQC (4-fiber Rosenberger Quad Connector) fiber jumper
can divectly connect RRHs and EasyLinkTM hybrid trunk cable
assembly or FTTA trunk cable assembly. Terminated with
Specification
Profile/Outline
Side A
Side A
Side B
Side B
Side B
B A
B A
Side A
0.5dB
0.3dB
50dB
50dB
Singlemode: G652D, G657A
Mulitmode: OM1, OM2, OM3, OM4
4.8mm
50mm
30mm
450N
300N
1KN/100mm
-40C ~ +80C
-40C ~ +80C
-20C ~ +65C
Compliant
RQC
LC
RQC
LC
Installation
Operation
Installation
Operation
Operation
Storage
Installation
Temperature Range
2002/95/EC (RoHS)
* Other cable size options are available upon request.
Ordering Information:
RQC Jumper Series
L98B-896-XXX
L98B-897-XXX
L98B-898-XXX
L98C-856-XXX
L98C-857-XXX
L98C-858-XXX
Fiber Type
G657A
OM2
Number Of Fiber
4
4
4
4
4
4
Top Connector
LCD with RFE
LCD
LCD with IP seal
LCD with RFE
LCD
LCD with IP seal
Bottom Connector
RQC
RQC
RQC
RQC
RQC
RQC
Ericsson
Huawei
Nokia
Ericsson
Huawei
Nokia
*XXX represents length (mm) from end to end. E.g. L98B-896-XXX means jumper length 5m.
37
Description
The RMC TM (Rosenberger Multi-fiber Connector) fiber jumper
can directly connect RRHs and EasyLink TM hybrid trunk cable
assembly or FTTA trunk cable assembly. Terminated with
Specification
RMCTM
LC
RMCTM
LC
0.5dB
0.3dB
50dB
50dB
G657A
OM2
6.0mm
50mm
30mm
450N
300N
3KN/100mm
-40C ~ +80C
-40C ~ +80C
-20C ~ +65C
Compliant
Fiber Type
Cable Diameter*
Installation
Operation
Installation
Operation
Operation
Storage
Installation
Temperature Range
2011/65/EU (RoHS)
Ordering Information
RMCTM Jumper Series
L98B-899-XXX
L98B-900-XXX
L98B-901-XXX
L98C-859-XXX
L98C-860-XXX
L98C-861-XXX
L98B-902-XXX
L98B-903-XXX
L98B-904-XXX
L98C-862-XXX
L98C-863-XXX
L98C-864-XXX
Fiber Type
G657A
OM2
G657A
OM2
Number Of Fiber
8
8
8
8
8
8
12
12
12
12
12
12
Top connector
LCD with RFE
LCD
LCD with IP seal
LCD with RFE
LCD
LCD with IP seal
LCD with RFE
LCD
LCD with IP seal
LCD with RFE
LCD
LCD with IP seal
Bottom Connector
RMCTM
RMCTM
RMCTM
RMCTM
RMCTM
RMCTM
RMCTM
RMCTM
RMCTM
RMCTM
RMCTM
RMCTM
*XXX represents length (mm) from end to end. E.g. L98B-896-XXX means jumper length 5m.
38
Ericsson
Huawei
Nokia
Ericsson
Huawei
Nokia
Ericsson
Huawei
Nokia
Ericsson
Huawei
Nokia
Hybrid Jumper
Description
The hybrid jumper can be used to connect RRH and EasyLinkTM
hybrid cable assembly with a hybrid distribution box on top of
tower. One end of jumper is usually terminated with LC connector
or other equipment vendor-specific interface, and the other
Specification
Profile/Outline
Side A
Side B Side A
Side B Side A
Side B
B A
B A
B A
B A
B A
B A
Specification
Fiber
Power
Open ended
Fiber
LC duplex
Power
Open ended
Fiber
0.75m
Power
0.75m
Fiber
0.5m
Power
0.5m
LC
0.3dB
LC
50dB
Installation
50mm
Operation
30mm
Installation
450N
Operation
300N
Side A(Top)
Side B(Bottom)
Breakout Cable Length*(Top)
Breakout Cable Length*(Bottom)
1KN/100mm
39
Temperature Range
Operation
-40C ~ +80C
Storage
-40C ~ +80C
Installation
-20C ~ +65C
2011/65/EU(RoHS)
Compliant
Hybrid Cable
Number of RRH
1 RRH
Number of Fiber
2 to 4
Number of Conductor
2 (1 pair)
Conductor Size
Jacket Material
LSZH, UV resistance
Armored Type
Corrugated aluminum
Singlemode: G652D, G657A
Fiber Type
Nominal Voltage
Uo/U 600/1000V
Flammability
IEC 60332-1
2011/65/EU(RoHS)
Compliant
Ordering Information
Hybrid Jumper Series
Fiber Type
L98Y-718-XXX
L98Y-717-XXX
G657A
L98Y-716-XXX
L98Y-727-XXX
L98Y-726-XXX
L98Y-725-XXX
OM2
Number Of Fiber
Conductor
Top Connector
Bottom Connector
6mm2
LCD
Ericsson
6mm
LCD
LCD
Huawei
6mm2
LCD
Nokia
6mm
LCD
Ericsson
6mm2
LCD
LCD
Huawei
LCD
Nokia
6mm
*XXX represents length (mm) from end to end. E.g. L98Y-718-XXX means jumper length 5m.
40
Distribution Box
Rosenberger ruggedized distribution box made of high-grade engineering plastic material provides the interconnection point between RRH jumpers and main FTTA trunk or hybrid cable assemblies. The distribution and interconnection of whatever main FTTA hybrid cable, fiber trunk cable and DC power trunk cable can be implemented
seamlessly and flexibly over cost-effective Rosenberger distribution boxes. It supports up to 6/12 RRHs which
makes the network cabling system installation, maintenance, upgrade and expansion possible and supports
multi-vendor installations. Standard and customized distribution boxes are available.
41
Description
Rosenberger fiber distribution box can be used at tower top or at bottom for fiber management, and it provides cost-effective and flexible
solution for installing multiple RRHs.
Specification
42
Number of RRH
Up to 12 RRH
Dimension (L x W x H)
Fiber Cores
Up to 24 fibers
Fiber Type
Mounting
Pole, wall
Material
Polycarbonate
Up to 4
FO cable (3-7mm)
FO cable (3-7mm)
Sealing of Jumpers
IP Rating
IP66
Operation Temperature
-40C ~ +85C
Earthing
Grounding cable
2011/65/EU (RoHS)
Compliant
Description
Rosenberger power distribution box can be used at tower top or at bottom for power management, and it provides cost-effective and
flexible solution for installing multiple RRHs. The box can be supplied with overvoltage protective (OVP) device.
Specification
Number of RRH
Dimension (L x W x H)
Up to 6 RRH
Mounting
Pole, wall
Material
Polycarbonate
1
6
2
2x4mm , 2x6mm
43
Description
Rosenberger Hybrid distribution box can be used at tower top or at bottom for both fiber and power management, and it provides costeffective and flexible solution for installing multiple RRHs. The box is with patented design by Rosenberger and is most suitable to be
installed with Rosenberger EasyLinkTM hybrid cables.
Specification
Number of RRH
Dimension (L x W x H)
DC Power
Fiber Cores
Up to 4 RRH
Up to 6 RRH
up to 4 pairs
up to 6 pairs
up to 16 fibers
Mounting
Pole, wall
Material
Polycarbonate
1 (7/8" cross-section)
2 (7/8" cross-section)
Hybrid Jumper
4 (1/2" cross-section)
6 (1/2" cross-section)
Sealing of Jumpers
IP Rating
Operation Temperature
Earthing
2011/65/EU (RoHS)
44
up to 24 fibers
Fiber Type
Installation Accessory
Rosenberger designs, manufactures and supplies the complete series of installation accessories for wireless cellular site feeder system including cable clamp, hoisting grip, cable tie, grounding kit, grounding bar, hose clamp,
weatherproof kit, cable entry kit, circuit breaker and etc. Particularly the standard sized cable clamps and grounding kits can be used as necessary for installing Rosenberger FTTA fiber cables and EasyLinkTM hybrid cables.
45
Cable Clamp
Description
Rosenberger cable clamps are universal parts which work with
different feeder cables and FTTA RRH installation solutions.
They are easy to install and allow for an upgrade or exchange
Ordering Information
46
Part Number
Description
SLCC111-C03
1/2"
SLCC121-C03
1/2"
SLCC131-C03
1/2"
SLCC111-C05
7/8"
SLCC121-C05
7/8"
SLCC131-C05
7/8"
SLCC111-C06
1-1/4"
SLCC121-C06
1-1/4"
SLCC131-C06
1-1/4"
SLCC211-C03
1/2"
SLCC221-C03
1/2"
SLCC231-C03
1/2"
SLCC211-C05
7/8"
SLCC221-C05
7/8"
SLCC231-C05
7/8"
SLCC211-C06
1-1/4"
SLCC221-C06
1-1/4"
SLCC231-C06
1-1/4"
SLCC211-ZF1
SLCC241-ZF1
SLCC261-ZF1
SLCC111-36.5
D36-37mm
SLCC121-36.5
D36-37mm
SLCC131-36.5
D36-37mm
SLCC115-32.5
D32-33mm
Grounding Kits
Description
Considering the expensive telecommunication equipments, it
is very important to set up the grounding well to prevent the
equipment from the lighting strikes. The grounding kits are the
key components which will be installed in field system every 4060m. Rosenberger grounding kits provide best diversion function
and the selected material guarantees the long-term site material
installation quality which has been proven by many customers
field application.
Ordering Information
Part Number
Description
SLGK001-C03-xxx1)
1/2"
1)
7/8"
SLGK001-C06-xxx1)
1-1/4"
1)
1/2"
SLGK004-C05-xxx1)
7/8"
1)
1-1/4"
All sizes
SLGK001-C05-xxx
SLGK004-C03-xxx
SLGK004-C06-xxx
SLGKT003D-xxx
2)
Note 1), XXX is the length of grounding wire which in cm. E.g. P/N: SLGK001-C03-150 The length of grounding wire is 150cm.
Hoisting Grips
Description
Hoisting Grips are available for a wide range of coaxial and hybrid
cable sizes, made up of mesh grip with single eye support and
it allows for quick and efficient installation. Different types are
available to be fit for most of different feeder cables and FTTA
RRH installation solutions.
Ordering Information
Part Number
Description
SLHG001-C03
1/2"
SLHG001-C05
7/8"
SLHG001-C06
1-1/4"
SLHG003-C03
1/2"
SLHG003-C05
7/8"
SLHG003-C06
1-1/4"
47
48
Description
All industry standard fiber optic connectivity together with
customized connectors are available from Rosenberger for
terminating to all kinds of patchcord and/or pigtail at different
Application
Channel to channel connection of fiber optic lines installed within
distribution panels or equipment
Connection of peripheral devices with a fiber optic interface
Specification
Fiber
Fiber Type
Multimode 62.5/125m
Standard
IEC 60793
ISO 11801
A1b
OM1
N/A
OM2
Multimode 50/125m
A1a
OM3
G651
OM4
B1.1
Singlemode 9/125m
OS1
G652A/G652B
B1.2
N/A
G654
B1.3
OS2
G652C/G652D
B2
N/A
G653
B4
N/A
G655
B5
N/A
G656
B6
N/A
G657A/G657B
49
Optical Cable
Cable Construction
Simplex Cable
Duplex Cable
Fiber QTY
Multi-Fiber
Optical Cable
Mini-Cable
1
4/6/8/12
24
Diameter (mm)
2.0
3.0
2.0*4.1
2.9*5.8
1.6
1.6*3.3
3.0
3.6
120
150
150
200
80
120
100
120
500
500
500
500
300
300
100
100
20
30
20
30
16
16
30
36
Temperature Range
-25 to +70
-20 to +70
Connector
Connector Optical Interface Standard
Connector Type
Interfaces Standard
SC
IEC 61754-4
Radius
725mm
Radius
512mm
FC
IEC 61754-13
Fiber Height
-100+50nm
Fiber Height
-100+50nm
ST
IEC 61754-2
Apex Offset
50 m
Apex Offset
50 m
N/A
Angle
8 0.3
PC
LC
IEC 61754-20
Angle
MU
IEC 61754-6
E2000
IEC 61754-15
MTP
IEC 61754-7
IEC 61755-3-32
Cable Assembly
LC, SC, FC, ST, MU
Connector Type
Fiber Type
SM
MM
E2000
SM
Max 0.3
MPO/MTP
MM
Max 0.3
Standard
SM
MM
0.6
0.5
See table1
IEC 61300-3-4
Method B
IEC 61300-3-6
Method 1
IEC 61300-3-6
Method 1
50
35
55
40
20
60
70
60
100
100
80
80
IEC 61300-2-4
-20 to +60
IEC 61300-2-22
70
-25 to +70
Ordering Information
HECM -
Fiber Optical
Cable Assembly
Length
(<1KM) XXXXXX
= XXXXXX mm
(1KM) XXX KM
=XXX KM
Cores
1=1F
2=2F
Cable Type
O=naked
H=LSZH
G=PVC(OFNG)
R=PVC(OFNR)
P=PVC(OFNP)
50
Type Of Fiber
1=OM1 62.5/125um
2=OM2 50/125um
3=OM3 50/125um
7=G657A1
9=G652D
A=G657A2
Shape of Cable
Y=roll
P=drop cable
Z=8 figure
Cable Dia.
2=2.0mm
3=3.0mm
6=1.6mm
8=1.8mm
9=0.9mm
Cable color
(If to be defined)
BL=Blue
OR=Orange
GR=Green
BR=Brown
SL=Slate
WH=White
RD=Red
BK=Black
YL=Yellow
VT=Violet
RS=Rose
RS=Rose
AQ=Aqua
Connector A
1=ST
2=SC
3=FC
4=LC
5=LCD
9=E2000
C=MU
D=SCD
Connector B
0=empty
1=ST
2=SC
3=FC
4=LC
5=LCD
9=E2000
C=MU
D=SCD
Polishing Level
(If to be defined)
A=APC(pigtail)
B=APC-APC
C=PC-APC
D=APC-PC
E=PC(pigtail)
Description
Rosenberger HDCS distribution & splice fiber optic patch panel
insures good management for the four critical elements of fiber
optic cable: bend radius protection, cable routing path, cable
access and physical protection. Those four aspects directly affect
the reliability, functionality and the operational cost of the network.
Specification
Sliding-type:
483 x 300 x 1HU (mm) and 483x 300 x 2HU (mm)
Fixed-type:
483 x 250 x 1HU (mm) and 483x 250 x 2HU (mm)
Delivery Form
Complete factory assembled panel
Dummy plugs in unused cable entries
Dummy plugs in unused front plate ports
Adapters ready in complete panel set
Ordering Information
10
Digit 1
1: 1 HU Distribution Panel
2: 1 HU Splice Panel
3: 1 HU Sliding Distribution Panel
4: 1 HU Sliding Splice Panel
Digit 2
1: SC/SC simplex SM
4: SC/SC simplex MM
5: SC/SC Duplex SM
6: SC/SC Duplex MM
C: LC/LC Duplex SM
D: LC/LC Duplex MM
E: FC/FC simplex
G: SC/APC simplex
K: E2000/E2000
Digit 3
2: 12 Fibers
3: 24 Fibers
4: 48 Fibers
6: 8 Fibers
7: 32 Fibers
8: 4 Fibers
C: 6 Fibers
D: 36 Fibers
Digit 4
5: Black
Digit 5
1A: Steel material
51
Description
Rosenberger high density fiber optic patch panels are designed
for 19" racks and compatible with common factory assembled or
on-site assembled cables, especially for Rosenberger factory preassembled cabling system.
Application
Rosenberger distribution & splice fiber optic patch panel insures
good management for the four critical elements of fiber optic
cable: bend radius protection, cable routing path, cable access
Specification
Dimension
MTP-LC Module Number of Fiber
Slots Number for MTP-LC Module
Max. Number of Fiber
MTP-LC Module Attenuation(Typical)
Single-mode
Multi-mode
Ordering Information
Ordering Number
Fiber Patch Panel
CPB1-110-41
CPB1-110-51
MTP-LC Module
CPB2-251-12
CPB2-253-12
CPB2-254-12
CPB2-255-12
Blind Cover
CPB4-611-11
52
Description
VelaTM 1HU Modular Fiber Patch Panel Fixed Type, Black, without Module
VelaTM 1HU Modular Fiber Patch Panel Pull-out, Black, without Module
VelaTM MTP -LC Module B, 12F, SM
VelaTM MTP -LC Module B, 12F, OM2
VelaTM MTP -LC Module B, 12F, OM3
VelaTM MTP -LC Module B, 12F, OM4
VelaTM Blind Cover
53
Description
Rosenberger provides different forms of D-sub cable assembly whice are to be widely used for data transmission between communication
and control equipments.
Application
Multiplexers
Mainframes
Engineering Workstations
Computers/Printers/Scanners
Specification
54
Product Series
Current (A)
Contact Styles
Standard Density
28-18
Solder or Crimp
High Density
28-22
Solder or Crimp
Description
Rosenberger CAT5e patch cord is used for network cabling transmission of voice, data and video signals. It supports current highbandwidth network applications and is especially suitable to IEC 11801 Class D standard requirements.
Application
VoIP
ISDN
Token ring
100 Mbps TP-PMD
Specification
Electrical Performance
Frequency
(MHz)
2m Cord
NEXT (dB)
5m Cord
10m Cord
RL
(dB)
65.0
65.0
65.0
19.8
62.3
61.5
60.4
21.6
56.4
55.6
54.7
22.5
10
54.5
53.7
52.8
22.8
16
50.4
49.8
48.9
23.4
20
48.6
47.9
47.1
23.7
25
46.7
46.0
45.3
24.0
31.25
44.8
44.2
43.6
23.0
62.5
39.0
38.5
38.1
20.0
100
35.1
34.8
34.6
18.0
55
Description
Rosenberger CAT6 patch cord is used for network cabling transmission of voice, data and video signals. It supports current highbandwidth network applications, and is especially suitable to IEC 11801 Class E standard requirements.
Application
VoIP
ISDN
Token ring
100 Mbps TP-PMD
Specification
Electrical Performance
56
NEXT (dB)
Frequency
(MHz)
2m Cord
5m Cord
10m Cord
RL
(dB)
65.0
65.0
65.0
19.8
65.0
65.0
65.0
21.6
65.0
65.0
64.8
22.5
10
65.0
64.5
62.9
22.8
16
62.0
60.5
59.0
23.4
20
60.1
58.6
57.2
23.7
25
58.1
56.8
55.4
24.0
31.25
56.2
54.9
53.6
23.0
62.5
50.4
49.2
48.1
20.0
100
46.4
45.3
44.4
18.0
125
44.5
43.5
42.7
17.0
150
43.0
42.1
41.4
16.2
175
41.8
40.9
40.2
15.5
200
40.6
39.8
39.3
15.0
225
39.7
38.9
38.4
14.5
250
38.8
38.1
37.6
14.0
Description
Rosenberger CAT6A patch cord is used for network cabling transmission of voice, data and video signals. It supports current highbandwidth applications, and is especially suitable IEC 11801 to Class EA standard requirements.
Application
VoIP
SDN
Token ring
100 Mbps TP-PMD
Analog and digital video
Specification
Electrical Performance
NEXT (dB)
Frequency
(MHz)
2m Cord
5m Cord
10m Cord
RL
(dB)
65.0
65.0
65.0
19.8
65.0
65.0
65.0
21.6
65.0
65.0
64.8
22.5
10
65.0
64.5
63.0
22.8
16
62.0
60.5
59.1
23.4
20
60.1
58.6
57.3
23.7
25
58.1
56.8
55.4
24.0
31.25
56.2
54.9
53.6
23.0
62.5
50.4
49.2
48.1
20.0
100
46.4
45.4
44.5
18.0
200
40.7
39.9
39.3
15.0
250
38.9
38.1
37.7
14.0
300
36.2
35.9
35.8
12.8
400
31.9
32.1
32.5
10.9
500
28.4
29.0
29.8
9.5
57
Customized Assembly
Type
Description
Specification
Parts
Connector: RJ45 8P8C connector (shielded)
Cable: AWG 26 120 8-pair
Assembly
Insulation resistance 100M
Dielectric strength AC, 250V, 1sec
Parts
Connector: RJ45 8P8C connector (shielded)
Cable: AWG 26 120 8-pair
Assembly
Insulation resistance 100M
Dielectric strength AC, 250V,1sec
Parts
Connector: BT43 75 connector
Cable: RS Multi 8*Coax Cable
Assembly
Insulation resistance 100M
Dielectric strength AC, 250V, 1sec
Multi-RJ45
Multi-RJ45
BT43 (SMZ)
R S E 1 / T 1 1 2 0 C a b l e A s s e m b l y Parts
p r o v i d e s t h e d i g i t a l t r a n s m i s s i o n Connector: 4*TQ connector, 120
Cable: AWG 26 120 8-pair
between communication equipments.
Assembly
Dielectric strength AC, 250V, 1sec
TQ Straight
SCSI PCM cable assembly provides
the digital transmission between
communication equipments.
High compact design with metal shell for
good EMI performance.
Parts
Connector: MDR IDC Plug 36Pin, Male
Shell: MDR Metal Junction shell 180exit
Cable: AWG26 120 SFTP PCM Cable
Assembly
Insulation resistance 100M
Dielectric strength AC, 250V, 1sec
Parts
Connector: MDR 68Position, Male
Shell: MDR metal junction shell
Cable: AWG26 100 SFTP PCM Cable,
Halogen free, Black
Assembly
Insulation resistance 10M
Dielectric strength AC, 250V, 1sec
SCSI
SCSI
58
Type
Description
Specification
Parts
Connector: Mini SNAP 4Pin Female
Cable: SEYVP 1*2/2*0.4 120
Assembly
Insulation resistance 100M
Dielectric strength AC, 250V, 1sec
Parts
Connector: RJ45 8P8C with seal boot
Connector: 1.0/2.3 straight plug with seal
boot, 75 Ohm
Cable 1: Cat.5e 24AWG*4P SFTP
Cable 2: RG179
Assembly
Insulation resistance 20M
Dielectric strength AC, 250V,1sec
Mini SNAP
Densi Shield
Parts
Connector: Densi-shield I/O Plug
Cable: AWG26 100 4P SF/UTP, LSZH
Assembly
Insulation resistance 5M
Dielectric strength AC, 250V, 1sec
59
Application
10baseT Ethernet
100baseTX Fast Ethernet
155Mbit ATM
622Mbit ATM
TR-16 Active
TR-16 Passive
Specification
Material
Electrical Property
Front Pane
Plastic
20M Max.
Contact
500M Min.
Contact Plating
Mechanical Property
60
750 times
30 Lbs
Temperature Range
-40C to +70C
Current Rating
Insulation Resistance
1.5 AMP
Application
10baseT Ethernet
100baseTX Fast Ethernet
1000baseTX Gigabit Ethernet
155Mbit ATM
622Mbit ATM
TR-16 Active
TR-16 Passive
Specification
Material
Electrical Property
Front Panel
Plastic
Current Rating
20M Max.
Contact
500M Min.
Contact Plating
Insulation Resistance
1.5 AMP
Mechanical Property
Plug Insertion Life
750 times
30 Lbs
Temperature Range
-40C to+70C
61
Application
10baseT Ethernet
100baseTX Fast Ethernet
1000baseTX Gigabit Ethernet
10Gbase-T Gigabit Ethernet
155Mbit ATM
622Mbit ATM
1.2 Gbit ATM
TR-16 Active/ Passive
Specification
Material
Electrical Property
Front Panel
Plastic
20M Max.
Contact
500M Min.
Contact Plating
Mechanical Property
Plug Insertion Life
Plug Retention Force
30 Lbs
Temperature Range
-40C to+70C
62
750 times
Current Rating
Insulation Rresistance
1.5 AMP
Balun Panel
Description
BNC to RJ45 impedance matching balun panel provides 75
coax (BNC connector) to 120 twisted pair (RJ45 connector)
conversion for 16 E1 channels (Tx and Rx). The panel conforms to
Application
The balun panel can be used for T1/E1/CPE network transmission
equipment and other applications.The balun panel can provide
Specification
Parts
Coaxial Connector
Twisted Pair Connector
Panel
Electrical Data At 20C
Insertion Loss
Cross Talk @1~100MHz
Return Loss
Insulation Resistance
Operating Condition
Matching Impedance
Bit Rate
Environmental Data
Temperature Range
2011/65/EC (RoHS)
63
Balun Panel
Description
The rack mounting Balun Panel converts 16 G.703 E1 or E2
circuits from unbalanced 75 coaxial to balanced 120 twisted
pair transmissions. Modular construction allows the user to hot
swap modules for other bit rates, functions or interfaces.
G.703/G.704 toolless insulating displacement connecting (IDC)
baluns are impedance matching 75 coax to 120 singleconductor connections. Various industry standard types of
coaxial connectors (75) are available including male and female
combinations of BNC, 1.6/5.6, 1.0/2.3, and Type 43.
Application
A bi-directional device requiring no external power which connects
telecommunications equipment with mismatching interfaces or
64
Specification
Parts
Type
Coaxial Connector
Pin Material
Insulator Material
Teflon
Mating cycles
500min
0.4 to 0.63mm
Insulation
0.7 to 1.1mm
Moulding Material
Polycarbonate White
Mating Cycles
50min
PC, Black
Size
Material
Return Loss
Pulse Shape
Cross Talk
Isolation Voltage
Operating Condition
Matching Impedance
Bit Rate
Signal Level
Environmental Data
Temperature Range
-40 C to +85 C
2011/65/EC (RoHS)
Compliant
65
Description
Rosenberger LSA module is specially designed for wall wounted box and MDF rack. It has connection and disconnection models, and is
convenient to be used for PCM cable connection. It is suitable for use in all communication networks such as DSL and IP network.
Application
Main distribution frames
Data and PABX distribution
Cross-connection cabinets
Specification
Mechanical Property
Housing Material
Contact Material
Plating
Allowed Wire
0.32-0.8mm
200 times
25N
Electrical Characteristics
66
Voltage Rating
12 VAC
Current Rating
1.5AMP
Insulation Resistance
1000Mohm@ 500VDC
3 milliohm
1min, (45~60) Hz
Description
The LSA distribution box is designed for both indoor and outdoor application, and can be mounted on the wall. There is a mounting frame
for fixing 2/10 or 2/8 LSA connection module or compatible disconnection module inside the box.
Application
It is suitable for PCM cable connection in all communication networks such as DSL and IP network.
Specification
Box Capacity
Box Size
Box Material
Frame Material
Modules Endurance
Operating Temperature
50 pair
100 pair
200 pair
320x240x110mm
320x320x110mm
400x600x110mm
2011/65/EU (RoHS)
Compliant
Flammability Rating
UL94V-0
Waterproof Performance
IP54
67
Description
Rosenberger LSA distribution frame is very convenient to be used for connecting and distributing PCM cables, which is designed in a
shape of ESTI 3HU for installing on a standard 19 open frame or rack. The distribution frame can be installed with up to 15pcs of LSA
terminal module providing 150-pair wiring and transmission capacity.
Application
It is suitable for PCM cable connection in all communication networks such as DSL and IP network.
Specification
Material
Frame Material
Stainless steel
Thickness
1.5mm
Terminal Material
Contact Material
Phosphor bronze
Plating
Allowed Wire
0.32-0.8mm
200 times
25N
Electrical Characteristics
68
Voltage Rating
12 VAC
Current Rating
1.5AMP
Insulation Resistance
1000Mohm@ 500VDC
3 milliohm
1min, (45~60) Hz
is the maximum allowable power consumption of RRH load with a desired cable design?
is the required cable configuration including conductor cross section of DC power cable at a certain
tower height?
What is the maximum allowed cable length between RRH and power supply unit with a specified cable
cross section and RRH (power consumption level)?
What
69
Description
Rosenberger D-sub type cable assembly is used for high-power DC transmission in an indoor enviroment. The cable assembly has
multi-pin D-sub connectors at both ends with male or female terminals.
Application
Ideal as an input/output of D-sub power interface. The high quality D-sub connector has mixed contact sizes for signal, power, coax,
thermocouple and high voltage applications.
Specification
Parts
Connector A
Connector B
D-sub body
2W2, 2V2, 3W3, 3V3, 4W4, 4V4, 5W5, 8W8
D-sub body
2W2, 2V2, 3W3, 3V3, 4W4, 4V4, 5W5, 8W8
Connector Material
Back Shell
Cable
Contact Resistance
10M Max.
Insulation Resistance
5000M, Min.
Dielectric Withstanding
1000V AC
Environmental Data
Installation Temperature
70
-10 C to +65 C
Operation Temperature
-20 C to +75 C
2011/65/EU (RoHS)
Compliant
Description
The ET 2 pole power cable assembly is used for power distribution units with small form connector. The ET connector is a low loss,
highly reliable and cost effective solution for cable-to-pcb application.
Application
Power distribution
Cellular base station sites
Computer servers and storage systems
Industrial electronic equipment cabinets
High reliability
Low profile right angle
Right-angle and vertical mounts available for ET connector
16AWG, 14AWG, 12AWG, 10AWG wire cables for option
Up to 30 Amps per contact
Specification
Parts
Connector
ET Power connector
Power Contact
Cable Jacket
Electrical Characteristics
Current
Environmental Data
Installation Temperature
-10 C to +65 C
Operation Temperature
-40 C to +70 C
2011/65/EU (RoHS)
Compliant
71
Description
Many of todays communication equipment including remote radio head (RRH) require DC power supply with different voltage rating
and connection interface. Rosenberger provides such power cable assembly in conjunction with hybrid FTTA solution, which is usually
terminated at one end with 2-pole or 3-pole outdoor power connector for connecting with hybrid cable and the other end left open.
Application
Most applicable for Power-To-The-Antenna (PTTA) requirements for transmitting the DC power up to RRH by connecting with hybrid
cable assembly.
Specification
Parts
Number of Connector Poles
Cable Conductor
Cable Ingress Protection
Cable Jacket Material
Cable Braid
Cable Diameter
Cable Bending Radius
2 or 3
4mm2 (12AWG)
IP67
PVC, UV-resistant, Black
Bare copper
9.2mm
Environmental Data
Operation Temperature
Installation Temperature
2011/65/EU (RoHS)
72
11.2mm
Operation
Installation
12outer diameter
6outer diameter
Wire to Earth
Wire to Wire
3.30/km
5 Mkm
0.6 kV
1 kV
Electrical Characteristics
DC resistance of conductor
Insulation resistance
Rating Voltage
6mm2 (10AWG)
-40 C to +70 C
-20 C to +60 C
Compliant
Description
Many of todays communication equipment including remote radio head (RRH) require DC power supply with different voltage rating and
connection interface. Rosenberger provides such multi-beam 2-pole power cable assembly in conjunction with hybrid FTTA solution,
which is usually terminated at one end with 2-pole multi-beam connector for connecting with RRH and the other end left open.
Application
Most applicable for Power-To-The-Antenna (PTTA) requirements for transmitting the DC power up to RRH by connecting with hybrid
cable assembly.
Specification
Parts
Connector Type
8 AWG
10 AWG
12 AWG
14 AWG
Electrical Characteristics
Current Rating
Voltage Rating
Dielectric Strength
Insulation Resistance
Dielectric Strength
45A
35A
25A
20A
105C, 600V
DC 1500V, 1min
20 M
AC 500V, 1sec
Environmental Data
Installation Temperature
-15 C to +60 C
Operation Temperature
-35 C to +80 C
2011/65/EU (RoHS)
Compliant
73
74
Description
Using as flexible connection joint in fiber optic network, where there is device with a fiber optic interface installed in outdoor or harsh
environment. Typical is for mobile communication (FTTA), broadcast, smart-grid cabling application.
Specification
Standard
Housing Material
Nickel-plated brass
Ferrule Material
PPS
Operating Temperature
Mechanical Resistance
>600N
Mating Cycles
>=500
Fiber Types
2011/65/EU(RoHS)
Compliant
75
Description
Using as flexible connection joint in fiber optic network, where there is device with a fiber optic interface installed in outdoor or harsh
environment. Typical is for mobile communication (FTTA), broadcast, smart-grid cabling application.
4 fibers connector
Support singlemode and multimode
Robust connector system with screwed locking mechanism
Components of the N coaxial connector according to MILPRF-39012 enable a conversion
With the standard panel cutout, the receptacle can easily
replace a coaxial connector type
Specification
76
Standard
Housing Material
Nickel-plated brass
Ferrule/Sleeve Material
Zirconia ceramic
Operating Temperature
Mechanical Resistance
>600N
Mating Cycles
>=1000
Fiber Types
2011/65/EU(RoHS)
Compliant
Description
Using as flexible connection joint in fiber optic network, where there is device with a fiber optic interface installed in outdoor or harsh
environment. Typical is for mobile communication (FTTA), broadcast, smart-grid cabling application.
2 fibers connector
Support singlemode and multimode
Robust connector system with screwed locking mechanism
Components of the N coaxial connector according to MILPRF-39012 enable a conversion
With the standard panel cutout, the receptacle can easily
replace a coaxial connector type
Specification
Standard
Housing Material
Nickel-plated brass
Ferrule/Sleeve Material
Zirconia ceramic
Operating Temperature
Mechanical Resistance
>600N
Mating Cycles
>=1000
Fiber Types
2011/65/EU(RoHS)
Compliant
77
Description
Using as flexible connection joint in fiber optic network, where there is device with a fiber optic interface installed in outdoor or harsh
environment. Typical is for mobile communication (FTTA), broadcast, smart-grid cabling application.
Specification
78
Nut Material
Housing Material
PA
Gasket Material
Silicon
Operating Temperature
Mechanical Resistance
>600N
Mating Cycles
>=1000
D4-D7
Connector Type
Standard LC duplex
2011/65/EU(RoHS)
Compliant
LC Loopback Connector
Description
LC Loopback is with standard LC duplex connector interface, available both single mode and multimode version. It is to make both optical
contacts connected together inside the packing which allows a self-test for device or a measurement of a link from one side. It can be used for
trouble shooting in field and also can be used to make transceiver test in research and development labs.
Specification
Standard
IEC 60754-20
Housing Material
PEI
Ferrule Material
Zirconica ceramic
Operating Temperature
-40~+75C
Mating Cycles
>=500
Flammability Rating
UL 94-V0
2011/65/EU (RoHS)
Compliant
Order Information
Part number
Description
98E-118
98E-119
98E-120
79
LC Connector
Description
Using as flexible connection joint in fiber optic network, where there is devices with a fiber optic interface installed in an indoor enviroment.
Typical is for mobile communication (FTTA), LAN, Data center network application.
Specification
80
Standard
IEC 61754-20
Housing Material
PEI
Ferrule/Sleeve Material
Zirconia ceramic
Operating Temperature
Mating Cycles
>=1000
Fiber Types
2011/65/EU(RoHS)
Compliant
SC Connector
Description
Using as flexible connection joint in fiber optic network, where there is device with a fiber optic interface installed in an indoor enviroment.
Typical is for mobile communication (FTTA), LAN, Data center network application.
Specification
Standard
Housing Material
PEI
Ferrule/Sleeve Material
Zirconia ceramic
Operating Temperature
Mating Cycles
>=1000
Fiber Types
2011/65/EU(RoHS)
Compliant
81
MU Connector
Description
Using as flexible connection joint in fiber optic network, where there is device with a fiber optic interface installed in an indoor enviroment.
Typical is for mobile communication (FTTA), LAN, Data center network application.
Specification
82
Standard
Housing Material
PEI
Ferrule/Sleeve Material
Zirconia ceramic
Operating Temperature
Mating Cycles
>=1000
D0.9-D3.0
Fiber Types
2011/65/EU(RoHS)
Compliant
E2000TM Connector
Description
Using as flexible connection joint in fiber optic network, where there is device with a fiber optic interface installed in an indoor enviroment.
Typical is for mobile communication (FTTA), LAN, Data center network application.
Single-fiber connector
Singlemode and multimode
Simplex, duplex and duplex-compact
Latched push-pull locking mechanism
Spring loaded ferrule, aligned in a slotted sleeve
Metal cap and plastic cap are available
Specification
Standard
Housing Material
PEI
Ferrule/Sleeve Material
Zirconia ceramic
Operating Temperature
Mating Cycles
>=1000
Fiber Types
2011/65/EU(RoHS)
Compliant
83
Housing Material
PA
Sealing Material
Silicone
3Nm
Operating Temperature
-40C~+70C
Mating Cycles
>25
D4.5-D9
Pulling Axial
>150N
Ordering Information
Part Number
Description
98Z105-S00
98Z105-S05
84
98Z105-S00/53
98Z105-S04
98Z105-S90-XXX
R99220107
85
Cable Standard
Rosenberger fiber optic cable complies with one or several of the following international standards.
DIN VDE 0888
TIA-EIA 598-B
IEC 60793
Telcordia GR-20
IEC 60794
Telcordia GR-409
IEC 60332-1/3
Pictograph
Flame-Retardant
The outer sheath of the cable is self-extinguishing
and not fire conductive.
UV-Resistant
The outer jacket of the cable is good performance on
UVresistant
Rodent- Retardant
The cable is protested against damage from the rodent.
86
UL Certification
Waterproof
RoHS-Compliant
Polyolefine
Flame Retardant
Polyvinyl
Chloride
Polyethylene
Polyurethane
Flame Retardant
Polyamide
Abbreviation
LSZH
PVC
PE
TPU/PR
PA(Nylon)
Combustion Properties
Halogen Free
Yes
No
Yes
Yes
Yes
Flame Retardant
Yes
Yes
No
Yes
No
Smoke Emission
Low
Strong
Medium
Medium
Strong
Corrosive Fumes
Low
High
No
Low
No
Low
Medium
Good
Good
Good
Flexibility
High
High
Low
High
Low
Hardness
Medium
Soft
Hard
Soft
Hard
Oil/Fuel
Good
Good
Good
Satisfactory
Good
Water
Good
Good
Very Good
Good
Satisfactory
Weathering
Good
Good
Very Good
Good
Good
Mechanical Properties
Abrasion Resistance
Resistance Against
Information given in the table is based on plastic materials used for cable jackets. Properties and resistance for cables can not
bederived from it.
The resistance against oil/fuel is meant as decision guidance to the best of our todays knowledge. It is based on typical values. The
resistance of cables has to be verified due to the wide variety of oils and fuels.
The resistance against weathering is same as the UV resistance and it highly depends on the color of jacket material used.
Test Procedure
Tensile Performance
Standard: IEC 60794-1-2 E1
Object: Detect the attenuation behavior and/or fiber elongation strain as a function of the
load on the cable when occur during installation. Meanwhile the tension applied shall be
within the maximum allowable tensile force.
Requirement: the result data shall not exceed the values given in the relevant detail
specification.
Abrasion
Standard: IEC 60794-1-2 E2
Object: Determines the ability of the cable sheath to resist abrasion and the ability of
cable markings to resist abrasion.
Requirement: No perforation of the sheath and optical continuity shall be maintained
andthe marking shall be legible after performing the number of cycles specified in the
detail specification.
87
Crush Resistance
Standard: IEC 60794-1-2 E3
Object: Determines the ability of the cable to withstand crushing and detect the influence
of the constant load on the attenuation.
Requirement: the result data shall not exceed the values given in the relevant detail
specification and no typical failure modes including the degradation transmission or
physical damage to the cable.
Impact Performance
Standard: IEC 60794-1-2 E4
Object: Determines the ability of the cable to withstand repeated impacts on the
attenuation and it simulates the dropping heavy objects such as stones and tools when
on operation.
Requirement: the result data shall not exceed the values given in the relevant detail
specification and no typical failure modes including the degradation transmission or
physical damage to the cable.
Repeated Bending
Standard: IEC 60794-1-2 E6
Object: Determines the ability of the cable to withstand repeated bending under tension
load and the two extreme positions make an angle of 90 degree on both sides of the
vertical.
Requirement: the result data shall not exceed the values given in the relevant detail
specification and no typical failure modes including the degradation transmission or
physical damage to the cable
Torsion
Standard: IEC 60794-1-2 E7
Object: Detects the ability of the cable to withstand the mechanical twisting and measures
any variation in the optical transmission when the cable is subjected to torsional forces
external to the cable jacket and evaluates the possibility of physical damage.
Requirement: the result data shall not exceed the values given in the relevant detail
specification and no typical failure modes including loss of optical continuity or physical
damage to the jacket or components
Flexing Performance
Standard: IEC 60794-1-2 E8
Object: Determines the ability of the cable to withstand repeated flexing, for example
elevator cable and measures any variation in the optical transmission when the cable is
on repeated flexing state and evaluates the possibility of physical damage.
Requirement: the result data shall not exceed the values given in the relevant detail
specification and no typical failure modes including loss of optical continuity or physical
damage to the jacket.
Temperature Cycling
Standard: IEC 60794-1-2 F1
Object: Determines the stability behavior of the attenuation of optical cables when the
temperature changes. It is generally the result of buckling or tensioning of fibers resulting
from differences between their thermal expansion coefficient and the coefficients of
strength and jacket members.
Requirement: the result data shall not exceed the values given in the relevant detail
specification and no typical failure modes including loss of optical continuity or physical
damage to the jacket
Water Penetration
88
89
Buffered Fiber
Description
Buffered fiber is made of bare fiber, fiber coating and buffer material. It is usually used for fiber optic link interconnection by terminating
with fiber optic connectors.
Specification
Profile/Outline
Core
Cladding
Coating
Buffer
Construction/Material
Fiber Type
Fiber Color
Buffer Material
Buffer Color
Temperature Range
90
-30 ~ +65
Installation Temperature
-20~ +50
Operation Temperature
-30 ~ +65
Mechanical Properties
Fiber
Count
Nominal
Buffer Diameter
(mm)
Nominal
Cable Weight
(Kg/Km)
Tensile Strength
Long-term/Short-term
(N)
Crush Resistance
Long-term/Short-term
(N/10cm)
Strip Length
In One Piece
Min.(mm)
0.6/0.9
0.9
3/6
100/500
30
30/50
G652D/G657A1/A2/B2/B3
G655C/D/E
OM1
OM2/OM2+
OM3/OM4
B1.3/B6a.1/2 B6b.2/3
B4
A1b
A1a/A1a.1
A1a.2/A1a.3
1310
1383
1550
1550
1625
850
1300
850
1300
850
1300
0.36
0.36
0.22
0.22
0.25
3.2
1.0
2.7
1.0
2.7
1.0
Ordering Information
RB - - -
1
1 Product Type
RB01 = Tight Buffer
RB02 = Semi-Tight Buffer
RB03 = Loose Buffer
2 Jacket Color
YL = Yellow
OR = Orange
BL = Blue
AQ = Aqua
GR = Green
3 Jacket Material
02 = LSZH
04 = PVC<OFNR>
05 = PVC<OFNP>
09 = Nylon
6 Fiber Symbol
G652D = Fiber G.652D
OM3 = Fiber OM3
OM4 = Fiber OM4
91
Description
Simplex fiber optic cable is made of buffered fiber, strength member and jacket material. It is usually used for fiber optic link
interconnection and patching by terminating with fiber optic connectors.
Specification
Profile/Outline
Core
Cladding
Coating
Buffer
Aramid Yarns Strength Member
Jacket
Construction/Material
Buffer
Buffer Color
Strength Member
Cable Jacket
Color of Jacket
Temperature Range
92
-20 ~ +70
Installation Temperature
-5 ~ +50
Operation Temperature
-20 ~ +70
Mechanical Properties
Nominal
Fiber
Cable Diameter
Count
(mm)
Nominal
Buffer Diameter
(Kg/Km)
Nominal
Cable Weight
(Kg/Km)
Tensile Strength
Long-term/Short-term
(N)
Crush Resistance
Long-term/Short-term
(N/10cm)
1.6
0.6
2.9
60/120
100/500
30/50
1.8
0.9
3.7
60/120
100/500
30/50
2.0
0.9
5.0
60/120
100/500
30/50
2.4
0.9
5.7
80/150
100/500
30/50
2.8
0.9
7.9
80/150
100/500
30/50
3.0
0.9
8.1
80/150
100/500
30/50
G652D/G657A1/A2/B2/B3
G655C/D/E
OM1
OM2/OM2+
OM3/OM4
B1.3/B6a.1/2 B6b.2/3
B4
A1b
A1a/A1a.1
A1a.2/A1a.3
Fiber Type
Wavelength
(nm)
Attenuation
(dB/Km)
1310
1383
1550
1550
1625
850
1300
850
1300
850
1300
0.45
0.45
0.35
0.35
0.40
3.5
1.5
3.2
1.2
3.0
1.0
Ordering Information
RI07- - - 0 0 1 -
1
8
5 Fiber Buffer Diameter
1 Product Type
6 = 600 um
9 = 900 um
2 Jacket Color
YL = Yellow
OR = Orange
BL = Blue
AQ = Aqua
GR = Green
T = Tight Buffer
S = Semi-Tight Buffer
L = Loose Buffer
7 Fiber Count
3 Jacket Material
001 = 1 Core
02 = LSZH
04 = PVC<OFNR>
05 = PVC<OFNP>
8 Fiber Symbol
4 Cable Diameter
16 = 1.6mm
24 = 2.4mm
18 = 1.8mm
28 = 2.8mm
20 = 2.0mm
30 = 3.0mm
93
Description
Duplex fiber optic cable is made of two buffered fibers, strength member and jacket material and in a figure of eight. It is usually used for
fiber optic link interconnection and cross-connect patching by terminating with fiber optic connectors.
Specification
Profile/Outline
Core
Cladding
Coating
Buffer
Aramid Yarns Strength Member
Jacket
Construction/Material
Buffer
Buffer Color
White/Blue or Blue/Orange
Other color specified available
Strength Member
Cable Jacket
Color of Jacket
Temperature Range
94
-20 ~ +70
Installation Temperature
-5 ~ +50
Operation Temperature
-20 ~ +70
Mechanical Properties
Nominal
Cable Diameter
(mm)
Nominal
Buffer Diameter
(mm)
Nominal
Cable Weight
(Kg/Km)
Tensile Strength
Long-term/Short-term
(N)
Crush Resistance
Long-term/Short-term
(N/10cm)
1.6*3.3
0.6
5.8
60/120
100/500
30/60
1.8*3.7
0.9
7.4
60/120
100/500
30/60
2.0*4.1
0.9
10.0
60/120
100/500
30/60
2.4*4.9
0.9
11.4
80/150
100/500
30/60
2.8*5.7
0.9
15.8
80/150
100/500
30/60
3.0*6.1
0.9
16.2
80/150
100/500
30/60
Fiber
Count
G652D/G657A1/A2/B2/B3
G655C/D/E
OM1
OM2/OM2+
OM3/OM4
B1.3/B6a.1/2 B6b.2/3
B4
A1b
A1a/A1a.1
A1a.2/A1a.3
1310
1383
1550
1550
1625
850
1300
850
1300
850
1300
0.45
0.45
0.35
0.35
0.40
3.5
1.5
3.2
1.2
3.0
1.0
Ordering Information
RI08- - - 0 0 2 -
1
8
5 Fiber Buffer Diameter
1 Product Type
6 = 600 m
9 = 900 m
2 Jacket Color
YL = Yellow
OR = Orange
BL = Blue
AQ = Aqua
GR = Green
T = Tight Buffer
S = Semi-Tight Buffer
L = Loose Buffer
7 Fiber Count
3 Jacket Material
002 = 2 Cores
02 = LSZH
04 = PVC<OFNR>
05 = PVC<OFNP>
8 Fiber Symbol
4 Cable Diameter
16 = 1.6mm
24 = 2.4mm
18 = 1.8mm
28 = 2.8mm
20 = 2.0mm
30 = 3.0mm
95
Description
Distribution fiber optic cable is made of multiple buffered fibers, strength member and jacket material as well as a ripcord as option. It is
usually used for fiber optic link interconnection, main trunk and building riser distribution with or without fiber optic connector terminated.
Specification
Profile/Outline
Fiber
Buffer
Aramid Yarns Strength Member
Ripcord (option)
Jacket
Construction/Material
Buffer
Buffer Color
Strength Member
Ripcord
Cable Jacket
Color of Jacket
Temperature Range
96
-20 ~ +70
Installation Temperature
-5 ~ +50
Operation Temperature
-20 ~ +70
Mechanical Properties
Fiber
Count
Subunit
Count
Nominal Cable
Diameter
(mm)
Nominal Cable
Weight(LSZH/PVC)
(Kg/Km)
Tensile Strength
Long-term/Short-term
(N)
Crush Resistance
Long-term/Short-term
(N/10cm)
4.0
14/13
130/440
200/1000
40/80
2
4
4.8
18/16
130/440
200/1000
48/96
5.1
23/20
130/440
200/1000
51/102
5.6
31/27
130/440
200/1000
55/110
10
5.8
34/29
130/440
200/1000
58/116
12
6.2
36/32
130/440
200/1000
62/124
18
8.1
57/53
130/440
200/1000
81/162
24
8.1
57/53
130/440
200/1000
81/162
G652D/G657A1/A2/B2/B3
G655C/D/E
OM1
OM2/OM2+
OM3/OM4
B1.3/B6a.1/2 B6b.2/3
B4
A1b
A1a/A1a.1
A1a.2/A1a.3
Fiber Type
Wavelength
(nm)
Attenuation
(dB/Km)
1310
1383
1550
1550
1625
850
1300
850
1300
850
1300
0.45
0.45
0.35
0.35
0.40
3.5
1.5
3.2
1.2
3.0
1.0
Ordering Information
RI12- - - -
1
1 Product Type
RI12 = Product code
2 Jacket Color
YL = Yellow
OR = Orange
BL = Blue
AQ = Aqua
GR = Green
3 Jacket Material
02 = LSZH
04 = PVC<OFNR>
05 = PVC<OFNP>
4 5
7
4 Fiber Buffer Diameter
6 = 600 m
9 = 900 m
6 Fiber Count
004 = 4 Cores
...
024 = 24 Cores
7 Fiber Symbol
G652D = Fiber G.652D
OM3 = Fiber OM3
OM4 = Fiber OM4
97
Description
Breakout fiber optic cable is made of multiple 2.0mm simplex cables, dielectric central strength member, wrap tape, jacket material and
a ripcord. It is usually used for fiber optic link interconnection, main trunk and building riser distribution by terminating with fiber optic
connectors.
Specification
Profile/Outline
Fiber
900um Buffer
Aramid Yarns Strength Member
2.0mm Fiber Subunit
FRP
Wrap Tape (option)
Ripcord (option)
Jacket
Construction/Material
Buffer
Buffer Color
Strength Member
Subunit Diameter
2.0mm
Subunit Jacket
Central Member
Ripcord
Cable Jacket
Temperature Range
98
-20 ~ +70
Installation Temperature
-5 ~ +50
Operation Temperature
-20 ~ +70
Mechanical Properties
Nominal Cable
Diameter
(mm)
Nominal Cable
Weight(LSZH/PVC)
(Kg/Km)
Tensile Strength
Long-term/Short-term
(N)
Crush Resistance
Long-term/Short-term
(N/10cm)
7.4
56/50
250/500
300/1000
74/148
7.4
56/50
250/500
300/1000
74/148
8.4
74/66
250/500
300/1000
84/168
Fiber
Count
9.8
101/91
500/1000
300/1000
98/196
12
12.0
134/121
500/1000
300/1000
120/240
16
12.4
155/140
500/1000
300/1000
124/248
24
14.4
201/181
500/1000
300/1000
144/288
G652D/G657A1/A2/B2/B3
B1.3/B6a.1/2 B6b.2/3
G655C/D/E
B4
OM1
A1b
OM2/OM2+
A1a/A1a.1
OM3/OM4
A1a.2/A1a.3
1310
1383
1550
1550
1625
850
1300
850
1300
850
1300
0.45
0.45
0.35
0.35
0.40
3.5
1.5
3.2
1.2
3.0
1.0
Ordering Information
RI14- - - -
1
1 Product Type
RI14 = Product No.
2 Jacket Color
YL = Yellow
OR = Orange
BL = Blue
AQ = Aqua
GR = Green
3 Jacket Material
02 = LSZH
04 = PVC<OFNR>
05 = PVC<OFNP>
4 Cable Diameter
20 = 2.0mm
8
5 Fiber Buffer Diameter
6 = 600 m
9 = 900 m
7 Fiber Count
002 = 2 Cores
...
024 = 24 Cores
8 Fiber Symbol
G652D = Fiber G.652D
OM3 = Fiber OM3
OM4 = Fiber OM4
99
Description
This specialized distribution fiber optic cable is designed for harsh environment application such as high performance fiber-to-theantenna (FTTA) cabling for current 3G and 4G/LTE network. The cable is made of multiple specialized buffered fibers, water-blocking
strength member and high quality jacket material to provide outstanding optical, mechanical and environmental performance.
Specification
Profile/Outline
Fiber
Tight Buffer
Strength Member
Jacket
Construction/Material
Buffer Type
Buffer Color
Strength Member
Cable Jacket
Color of Jacket
Temperature Range
Transport and Storage
Installation
-20 ~ +60
Operation
-40 ~ +85
Mechanical Properties
Nominal
Cable Diameter
(mm)
4.8
Nominal
Cable Weight
(Kg/Km)
18
Tensile Strength
Long-term/Short-term
(N)
300/450
Crush Resistance
Long-term/Short-term
(N/10cm)
1000/2200
5.2
18
300/450
1000/2200
48/96
Fiber
Count
100
G652D/G657A1/A2/B2/B3
G655C/D/E
B1.3/B6a.1/2 B6b.2/3
OM1
B4
OM2/OM2+
A1b
A1a/A1a.1
OM3/OM4
A1a.2/A1a.3
Wavelength(nm)
1310
1383
1550
1550
1625
850
1300
850
1300
850
1300
Attenuation(dB/Km)
0.45
0.45
0.35
0.35
0.40
3.5
1.5
3.2
1.2
3.0
1.0
Description
This type of armored fiber optic cable is designed for harsh environment application such as high performance fiber-to-the-antenna (FTTA)
cabling for current 3G and 4G/LTE network. The cable is made of multiple specialized buffered fibers, spiral stainless steel amore
tube, water-blocking strength member and high quality jacket material to provide outstanding optical, mechanical and environmental
performance as well as rodent protection capability.
Specification
Fiber
Profile/Outline
Tight Buffer
Spiral Amored Tube
Strength Member
Jacket
Construction/Material
Buffer Type
Buffer Color
Armored
Strength Member
Cable Jacket
Color of Jacket
Temperature Range
Transport and Storage Temperature
-40 ~ +85
Installation Temperature
-20 ~ +65
Operation Temperature
-40 ~ +85
Mechanical Properties
Fiber
Count
Nominal
Cable Diameter
(mm)
Nominal
Cable Weight
(Kg/Km)
Crush Resistance
Long-term/Short-term
(N/10cm)
4.8
38.5
300/450
1000/3000
48/96
G652D/G657A1/A2/B2/B3
G655C/D/E
OM1
OM2/OM2+
OM3/OM4
B1.3/B6a.1/2 B6b.2/3
B4
A1b
A1a/A1a.1
A1a.2/A1a.3
Wavelength(nm)
1310
1383
1550
1550
1625
850
1300
850
1300
850
1300
Attenuation(dB/Km)
0.45
0.45
0.35
0.35
0.40
3.5
1.5
3.2
1.2
3.0
1.0
101
Description
This type of specialized breakout fiber optic cable is designed for harsh environment application such as high performance fiber-to-theantenna (FTTA) cabling for current 3G and 4G/LTE network. The cable is made of multiple 2.0mm subunits, water-blocking strength
member and high quality jacket material to provide outstanding optical, mechanical and environmental performance.
Specification
Tight Buffer
Profile/Outline
Jacket
Construction/Material
Buffer Type
Buffer Color
Sub-unit Jacket
Sub-unit Jacket Color (2-core)
Sub-unit Jacket Diameter
Strength Member
Cable Jacket
Color of Jacket
Temperature Range
Transport and Storage Temperature
Installation Temperature
Operation Temperature
Mechanical Properties
Fiber
Count
Nominal
Cable Diameter
(mm)
Fiber
Structure
(mm)
Nominal
Cable Weight
(Kg/Km)
Tensile Strength
Long-term/Short-term
(N)
Crush Resistance
Long-term/Short-term
(N/10cm)
7.0
0.6/0.9
38
200/400
1000/2200
70/140
102
G652D/G657A1/A2/B2/B3
G655C/D/E
OM1
OM2/OM2+
OM3/OM4
B1.3/B6a.1/2 B6b.2/3
B4
A1b
A1a/A1a.1
A1a.2/A1a.3
Wavelength(nm)
1310
1383
1550
1550
1625
850
1300
850
1300
850
1300
Attenuation(dB/Km)
0.45
0.45
0.35
0.35
0.40
3.5
1.5
3.2
1.2
3.0
1.0
103
www.rosenberger.com
www.rosenbergerap.com
No.3, Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China 101300
Tel : (+86 10) 80481995
I
E-mail: info@rosenbergerap.com
Fax : (+86 10) 80497052
I
Web: www.rosenbergerap.com
Rosenberger (Shanghai) Technology Co., Ltd.
B7, No. 509, Renqing Road, East Zone of Zhangjiang High-Tech Park, Shanghai, China 201201
Tel : (+86 21) 58995997
I
E-mail: info@rosenbergerap.com
Fax : (+86 21) 58995994
I
Web: www.rosenbergerap.com
Rosenberger Technology (Kunshan) Co., Ltd.
No.6, Shenan Road, Dianshanhu Town, Kunshan, Jiangsu, China 215345
Tel : (+86 512) 86896789
I
E-mail: info@rosenbergerap.com
Fax : (+86 512) 86890666
I
Web: www.rosenbergerap.com