VirtuallyInline(Bypass)TAPSolutions
TheSmartNetworkAccessSystemfromNetworkCriticalallowsyoutodeployall of
yourappliancesriskfreeinyournetworkinfrastructurewhileensuringcomplete
visibilityofalltrafficflowingonyournetwork.
SNAV2
www.networkcritical.com
Page|1of7
VirtuallyInline(Bypass)TAPSolutions
SupportsThree(3)TAPModes
ConfigureTAPModulein3differentTAPmodeswithoutlosingLink
VLine(ByPass)TAPMode
V-Line (Bypass) Mode
V-Line
TAP
Firewall
Switch
VLINETAPMODE
Providestheabilitytoinstall
InLineApplianceswithnoRISK
ofnetworkdowntime
Network
Appliance
AggregatingTAPMode
BreakoutTAPMode
AGGREGATINGTAPMODE
Uniquepacketslicingfeature
Passesallphysicallayererrors.
Supportspacketinjection
BREAKOUTTAPMODE
ChangebetweenAggregation
TAPMode,BreakoutTAPmode,
andVLineTAPModewithout
breakingthelink
TheSmartWaytoGainAccesstoyourNetwork
SNAV2
www.networkcritical.com
Page|2of7
VirtuallyInline(Bypass)TAPSolutions
VLineTAPModuleFeatures:
Simple,secure,configurableandflexible
EmploysNetworkCriticalsFailSafeTechnology
Canbeconfiguredinto3availableTAPmodes:
o VLineTAP
o BreakoutTAP
o AggregatingTAP
Abletoswitchbetweenall3TAPmodeswithoutlosingnetworklink
Supportsjumboframesupto16,383byteswithCRC
Passesallphysicallayererrors
InvisibletothenetworknoIPaddressorMACaddress
ExclusiveVLine(Bypass)designprovidesnolinklosswhentheTAPconvertsintoByPassmode
ExclusiveVLine(Bypass)designprovidesbidirectionalheartbeatsthatguaranteetheabilityto
recognizewhentheInLineAppliancehasfailed.
o Ourcompetitiononlysupportsunidirectionalheartbeats.
AggregationModesupportsPacketSlicingonthemonitoringports.Packetslicinglimitsthepacket
sizebeingreplicatedoutthemonitoringportswitharecalculatedCRC(cansliceupto4095bytes).
AggregationModesupportsPacketInjection(PI)/BiDirectionalTrafficFlow
Eliminatetherisksofinstallingyourapplianceinline.
InstallitVirtuallyInlineinstead!
RisksofInstallinganApplianceInLine
UseaVLineTAPinstead!
Networkdowntimecanoccurwhenmaintenance ByinstallingaVLineTAP,youcandomaintenanceon
andupgradesareperformedontheappliance.
yourappliancewithouttakingdownthenetwork.
VLine(bypass)technologywillbypasstheInline
Whenpowerislosttotheinlineappliance,the
AppliancewithoutlosinglinkwhenInLineAppliance
networkwillgodown.
losespower
Inlineappliancescanblockormodifytrafficin
VLineTAPsarecompletelypassiveandwillnotblock
thenetworkdatastream.
ormodifytraffic.
Inlineappliancescancauseunpredictable
VLineTAPsareanallhardwaresolutioneliminating
operationsasexperiencedwithstacked
theunpredictabilityofsoftwareinstalledinlineinyour
OS/SoftwareSystems.
network.
SNAV2
www.networkcritical.com
Page|3of7
VirtuallyInline(Bypass)TAPSolutions
HowdoVLineTAPswork?
WhatisBypassMode?
WhenaVLineTAPisinstalledinplaceofaninlineappliance,theVLineTAPisabletocontinuallycheckthestatusof
theapplianceandifitisonline,willdirecttrafficthroughit.Iftheappliancegoesofflineforanyreason,theVLine
TAPwillautomaticallybypasstheapplianceanddirecttrafficstraightthroughtothenetwork.Whentheappliance
comesbackonline,trafficisonceagaindirectedthroughtheappliance.
HowdoestheTAPdetectiftheapplianceisonline?
Heartbeatpacketsareinjectedintothetrafficstreamandaredirectedtothemonitoringdeviceat15Heartbeat
packetspersecond.Ifthe15HeartbeatpacketsarenotdetectedwhenthetrafficispassedbackthroughtheVLine
TAPontheirwaybacktothenetwork,theTAPentersBypassmodeandbypassestheappliance.Heartbeatpackets
areNEVERsentontothelivenetwork.
VLine(Bypass)TAP
VLine(Bypass)TAP
SNAV2
www.networkcritical.com
Page|4of7
VirtuallyInline(Bypass)TAPSolutions
CarrierGradeChassisDesigns
NetworkCriticalsinnovativehighdensity,carriergradechassisdesignsmaketheSmartNetworkAccess
SystemtheonlyAccessSolutionyouwilleverneed.
PortableChassis
Features
1UChassis
2UChassis
Builtinmanagementport
Controlmoduleavailable
DualACpowersupplies
available
DualDCpowersupplies
available
Localorremote
configuration
SupportsCopperModules
SupportsFiberModules
Aggregatingand
RegeneratingBackplane
#ofmoduleslots
#ofexpansionslots
SizeDimensions(WxHx
D)
Weight
OperatingTemperature
OperatingRelative
Humidity
StorageTemperature
Voltage(AC/DC)
1
0
5.8inx1.8inx7.5in/14.7cmx
4.6cmx19.1cm
1.4lbs/0.6kg
+32Fto+104F/0Cto+40C
4
1
17.33inx1.73inx12.44in/44.05
cmx4.4cmx31.63cm
7.0lbs/3.2kg
+32Fto+104F/0Cto+40C
12
3
17.33inx3.46inx12.44in/
44.02cmx8.80cmx31.60cm
8.7lbs/3.9kg
+32Fto+104F/0Cto+40C
90%noncondensing
90%noncondensing
90%noncondensing
4Cto+158F/20Cto+70C
85V264VAC/7V60VDC
Current(nominal)
1.25@12VDC
Max.PowerConsumption
MeanTimeBetween
Failures(MTBF)
7Watts
4Cto+158F/20Cto+70C
4Cto+158F/20Cto+70C
85V264VAC/36V72VDC
85V264VAC/36V72VDC
.22A@230VAC/0.44A@110VAC 6A@115VAC/3A@230VAC
/1.5A@50VDC
/1.5A@50VDC
50Watts
100Watts
465,000+hours
465,000+hours
465,000+hours
SNAV2
www.networkcritical.com
Page|5of7
VirtuallyInline(Bypass)TAPSolutions
TheGreenerSolutionforYourDataCenter
CompareNetworkCriticalsDataCenterSolutionwiththeCompetitions
Portable/StandaloneSolutions
NetworkCriticalsSolution
Competitions Solution
4VLineTAPs
4VLineTAPs
o Takesup1Uofrackspace
o Takesup2Uofrackspace
o Uses(2)ACorDCpower
supplies
o Requires(1)IPaddress
connectionfor
managementand
configuration
o Hotswappablemodules
o Uses(8)externalpower
supplies
o Requires(4)IPaddressesand
(4)switchportsfor
managementand
configuration
o Fixedproductwithno
flexibility
12VLineTAPs
o Takesup2Uofrackspace
o Uses(2)ACorDCswitch
stylepowersupplies
o Requires(1)IPaddress
formanagementand
configuration
o Hotswappablemodules
12VLineTAPs
o Takesup6Uofrackspace
o Uses(24)externalpower
supplies
o Requires(12)IPaddresses
and(12)switchportsfor
managementand
configuration
o Fixedproductwithno
flexibility
NetworkCriticalsDataCenterSolutionssaveyou:
Money
Energy
RackSpace
IPAddresses
SNAV2
SwitchPorts
UPSports&PowerOutlets
www.networkcritical.com
Page|6of7
VirtuallyInline(Bypass)TAPSolutions
OrderingInformation
SNAC0AC
PortableModularChassis,1HotSwappablemoduleslot,DualACpowersupplies
SNAC0DC
PortableModularChassis,1HotSwappablemoduleslot,DualDCpowersupplies
SNAC1AC
1UModularChassis,4HotSwappablemoduleslots,1expansionslot,AggregatingandRegenerating
Backplane,DualACpowersupplies
SNAC1DC
1UModularChassis,4HotSwappablemoduleslots,1expansionslot,AggregatingandRegenerating
Backplane,DualDCpowersupplies
SNAC2AC
2UModularChassis,12HotSwappablemoduleslots,3expansionslot,DualACpowersupplies
SNAC2DC
2UModularChassis,12HotSwappablemoduleslots,3expansionslot,DualDCpowersupplies
SNAMRJRJV
SNAMRJSFV
SNAMMSSFV
SNAMMSRJV
SNAMSSSFV
10/100/1000CopperRJ45VLine(Bypass), BreakoutandAggregatingTAPModulewith(2)10/100/1000
CopperRJ45programmableBidirectionalMonitorPorts
10/100/1000CopperRJ45VLine(Bypass), Breakout, andAggregatingTAPModuleand(2)GigabitSFP
MonitoringPorts
MultimodeGigabitFiber(1000BaseSX)VLine(Bypass), Breakout,andAggregatingTAP Modulewithtwo(2)
GigabitSFPMonitorPorts
MultiModeGigabitFiber(1000BaseSX)VLine(Bypass),Breakout,andAggregatingTAPModulewith(2)
CopperGigabitMonitoringPorts
SingleModeGigabitFiber(1000BaseSX/LH)VLine(Bypass),Breakout,andAggregatingTAPModulewithtwo
(2)SFPCageMonitoringPorts
SNAMSSRJV
SingleModeGigabitFiber(1000BaseSX/LH)VLine(Bypass),Breakout,andAggregatingTAPModulewithtwo
(2)RJ45CopperGigabitMonitoringPorts
SNAERJ6
BackplaneControl&SecurityModulewith1 RJ45CopperManagementPort&1RJ45CopperMonitoring
Port
SNAESF6
BackplaneControl&SecurityModulewith1SFPCageManagementPort&1SFPCageMonitoringPort
SFPTX
1000BaseTXCopperGigabitSFPRJ45Connector
SFPSX
1000BaseSXMultimodeGigabitFiber850nmSPFLCConnector
SFPLX
1000BaseLXSinglemodeGigabitFiber1310nmSFPLCConnector
SFPZX
1000BaseZXSingleModeGigabitFiber1550nmLCConnector
CC1U3
Rackmountplateholds3PortableChassis
TolearnmoreabouttheSmartNetworkAccessSystem,
ContactNetworkCritical:
HeadquartersOffice
12BSouthviewPark
Caversham,ReadingRG45AF
(0)1189543210
SNAV2
www.networkcritical.com
AmericasOffice
3675HarlemRoad
Buffalo,NewYork14215
(716)5587280
Page|7of7