Beruflich Dokumente
Kultur Dokumente
Tankguard HB
Product description
Tankguard HB is a high-build epoxy coating with high resistance to a wide range of chemicals and solvents.
Recommended use
Interiors of tanks and gas pipes. A separate resistance list is available.
Minimum
80
160
6,3
Maximum
150
300
3,3
Typical
100
200
5
Physical properties
Colour
Solids (vol %)*
Flash point
25C 2 (Setaflash)
VOC
Gloss
Flat
Water resistance
Very good
Abrasion resistance
Very good
Solvent resistance
Excellent
Chemical resistance
Excellent
*Measured according to ISO 3233:1998 (E)
Surface preparation
All surfaces should be clean, dry and free from contamination. The surface should be assessed and treated in
accordance with ISO 8504.
Bare steel
Cleanliness: Blast cleaning to min. Sa 2 (ISO 8501 1:2007). Roughness: using abrasives suitable to achieve Grade
Medium G (50 - 85 m, Ry5) (ISO 8503-2).
Other surfaces
The coating may be used on other substrates. Please contact your local Jotun office for more information.
Tankguard HB
Page 1 of 3
Application methods
Spray
Brush
Application data
Mixing ratio (volume)
4 parts Comp. A (base) to be mixed thoroughly with 1 part Comp. B (curing agent)
Mixing
Pot life (23C)
Thinner/Cleaner
Guiding data airless spray
Pressure at nozzle
Nozzle tip
Spray angle
Filter
Drying time
Drying times are generally related to air circulation, temperature, film thickness and number of coats, and will be
affected correspondingly. The figures given in the table are typical with:
* Good ventilation (Outdoor exposure or free circulation of air)
* Typical film thickness
* One coat on top of inert substrate
Substrate temperature
Surface dry
Through dry
Cured 2
Dry to recoat, minimum
Dry to recoat, maximum 1
1.
2.
5C
12 h
36 h
36 h
28 d
10C
7h
24 h
14 d
24 h
25 d
23C
3,5 h
6h
7d
12 h
21 d
40C
1,5 h
4h
3d
5h
7d
The surface should be dry and free from any contamination prior to application. If the maximum dry to recoat time is
exceeded, please contact your local Jotun office for more information.
To achieve full chemical resistance a substrate temperature of at least 10C is needed.
The given data must be considered as guidelines only. The actual drying time/times before recoating may be shorter or
longer, depending on film thickness, ventilation, humidity, underlying paint system, requirement for early handling and
mechanical strength etc. A complete system can be described on a system sheet, where all parameters and special
conditions could be included.
Tankguard HB
3 x 100 m
Page 2 of 3
Storage
The product must be stored in accordance with national regulations. Storage conditions are to keep the containers in a
dry, cool, well ventilated space and away from source of heat and ignition. Containers must be kept tightly closed.
Handling
Handle with care. Stir well before use.
Packing size
20 litre unit: 16 litres Comp. A (base) in a 20 litre container and 4 litres Comp. B (curing agent) in a 5 litre container
Tankguard HB
Page 3 of 3