Version 8.3
Contents
About This Manual ................................................................... xv
Overview ............................................................................................................ xv
Intended Audience ............................................................................................. xv
Document Organization ..................................................................................... xvi
Document Conventions ..................................................................................... xvi
Related Documentation .................................................................................... xvii
Obtaining Technical Documentation ................................................................xviii
Technical Assistance........................................................................................xviii
417006-2304-0H3-B02
Contents
ii
417006-2304-0H3-B02
Contents
Overview ..........................................................................................................C-1
16- to 32-Channel Mux/DeMux Expansion ....................................................... C-2
Upgrading and Expanding Optical Networks .................................................... C-3
Matrix and SDH Data Card Upgrades .............................................................. C-7
417006-2304-0H3-B02
iii
Contents
iv
417006-2304-0H3-B02
List of Figures
Figure 1-1: Optical rack grounding bar and rack frame grounding post ........................ 1-8
Figure 1-2: Grounding the optical rack to the site grounding bar................................... 1-9
Figure 1-3: XDM shelves warning labels ..................................................................... 1-17
Figure 1-4: Power input warning label ......................................................................... 1-17
Figure 1-5: Basic ESD warning symbol ....................................................................... 1-26
Figure 1-6: Typical temporary EPA arrangement ........................................................ 1-29
Figure 1-7: Pollution control logos ............................................................................... 1-32
Figure 1-8: WEEE recycling symbol ............................................................................ 1-33
Figure 2-1: XDM-500 platform........................................................................................ 2-7
Figure 2-2: XDM-500 slot allocation ............................................................................... 2-8
Figure 3-1: A typical XDM-1000 product line installation components .......................... 3-4
Figure 4-1: Deep vs. standard door ............................................................................... 4-3
Figure 4-2: Optical rack components ........................................................................... 4-13
Figure 4-3: Type A ETSI rack general view ................................................................. 4-15
Figure 4-4: Type A ETSI rack internal view ................................................................. 4-16
Figure 4-5: ETSI A rack closed view ............................................................................ 4-18
Figure 4-6: XDM-1000 and XDM-500 shelves in a 2600 mm rack .............................. 4-21
Figure 4-7: Two XDM-500 shelves in a 2200 mm rack ................................................ 4-22
Figure 4-8: Rack and platform grounding posts on the XDM-1000 ............................. 4-25
Figure 4-9: Short boot characteristics .......................................................................... 4-32
Figure 4-10: Mounting diagrams for ETSI racks .......................................................... 4-38
Figure 4-11: Mounting diagrams for 19 in. and 23 in. racks ........................................ 4-39
Figure 4-12: Rack mounting diagram for attachment to suspended overhead
tray (2200 mm rack) ..................................................................................................... 4-41
Figure 4-13: Optical rack grounding bar and rack frame grounding post .................... 4-42
Figure 4-14: Grounding the optical rack to the site grounding bar............................... 4-43
Figure 4-15: xRAP-D power supply flow ...................................................................... 4-46
Figure 4-16: xRAP-D power supply with bridge, two variations ................................... 4-47
Figure 4-17: Location of xRAP-D grounding stud ........................................................ 4-48
Figure 4-18: xRAP-D power supply flow ...................................................................... 4-49
Figure 4-19: Identification of xRAP-D cable routes ...................................................... 4-50
Figure 4-20: Connecting DC power cables .................................................................. 4-51
Figure 4-21: xRAP-D power supply with bridge, two variations ................................... 4-53
Figure 4-22: Identification of xRAP-D cable routes ...................................................... 4-54
Figure 4-23: Connecting DC power cables .................................................................. 4-55
Figure 4-24: Side screws highlighted on left side of xRAP-D unit ............................... 4-57
417006-2304-0H3-B02
List of Figures
417006-2304-0H3-B02
List of Figures
Figure 5-1: XDM shelf and rack grounding (NEBS-compliant) ...................................... 5-5
Figure 5-2: Air filter and installation kit ........................................................................... 5-7
Figure 5-3: Installing the air filter frame ......................................................................... 5-8
Figure 5-4: Installing the air filter in its frame ................................................................. 5-9
Figure 5-5: Grounding connections at typical site ........................................................ 5-10
Figure 5-6: Auxiliary connector panel .......................................................................... 5-12
Figure 6-1: XDM-500 slots identification ........................................................................ 6-4
Figure 6-2: Inserting an SFP into an optical module .................................................... 6-12
Figure 6-3: Installing extractable OM01_4 and OM04_1 optical modules in
SIO1&4 cards ............................................................................................................... 6-14
Figure 6-4: Installing extractable OMS01_4 and OMS04_1 optical modules
in SIO1&4 cards ........................................................................................................... 6-16
Figure 6-5: Installing an extractable optical OM16_1 module in SIO16 card .............. 6-18
Figure 6-6: Installing an extractable optical OM16_1SFP module in SIO16 card ....... 6-20
Figure 6-7: Installing an OMSC16_4 module on SIO164 ............................................ 6-22
Figure 6-8: Installing an optical module on SIO164 ..................................................... 6-24
Figure 6-9: Installing extractable optical modules in the XIO192................................. 6-26
Figure 6-10: Installing an optical module on XIO384F ................................................. 6-28
Figure 6-11: Identifying the installation positions on the SIO1&4B card ...................... 6-30
Figure 6-12: Identifying the installation positions on the SIO16_2B card .................... 6-31
Figure 6-13: Identifying the installation positions on the SIO16_4B card .................... 6-32
Figure 6-14: Identifying the installation positions on the SIO64B card ........................ 6-33
Figure 6-15: Identifying the installation positions on typical EIS cards ........................ 6-35
Figure 6-16: Identifying the installation positions on DIO cards................................... 6-37
Figure 6-17: Identifying the installation positions on typical DIOB cards ..................... 6-39
Figure 6-18: Identifying the installation positions on typical MCS5/MCS10 cards....... 6-41
Figure 6-19: Identifying installation positions on the MCS30_X10G ........................... 6-43
Figure 6-20: Installing an extractable module in a CMBR10_D card ........................... 6-45
Figure 6-21: Identifying optical transceiver plug-in installation positions in
CMBR10_D/DO cards .................................................................................................. 6-46
Figure 6-22: Installing an extractable module in a CMBR10_B/BO card ..................... 6-47
Figure 6-23: Identifying optical transceiver plug-in installation positions in
CMBR10_B/BO cards .................................................................................................. 6-48
Figure 6-24: Installing a typical extractable optical module in a CMBR25_2 card....... 6-49
Figure 6-25: Installing extractable modules in a CMTR25 card ................................... 6-51
Figure 6-26: Identifying the installation positions on the CMBR40 card ...................... 6-53
Figure 6-27: Installing plug-in modules in a TRP10_2B card ...................................... 6-54
Figure 6-28: Identifying the installation positions on a TRP10_4R card ...................... 6-55
Figure 6-29: Identifying the installation positions on a TRP10_4M card ..................... 6-56
Figure 6-30: Installing plug-in modules in a TRP10_LAN card .................................... 6-57
417006-2304-0H3-B02
vii
List of Figures
viii
417006-2304-0H3-B02
List of Figures
417006-2304-0H3-B02
ix
List of Figures
Figure A-31: DDF general view with cover closed ...................................................... A-34
Figure A-32: DDF general view with cover open ........................................................ A-34
Figure A-33: Typical 84-channel patch panel for balanced E1 interfaces
general views ............................................................................................................... A-35
Figure B-1: 3-pin power connector ................................................................................. B-2
Figure B-2: 5-pin power connector ................................................................................. B-2
Figure B-3: ALARMS connector pin identification .......................................................... B-3
Figure B-4: RAP connector pin identification ................................................................. B-4
Figure B-5: F-CHANNEL connector pin identification .................................................... B-5
Figure B-6: T3_1/T4_1 and T3_2/T4_2 connector pin identification.............................. B-6
Figure B-7: OW connector pin identification .................................................................. B-7
Figure B-8: OHA connector pin identification ................................................................. B-8
Figure B-9: MECP ETHERNET connector pin identification........................................ B-10
Figure B-10: ACP900 connector pin identification ....................................................... B-11
Figure B-11: M2_84 14-tributary connector pin identification ...................................... B-12
Figure B-12: Alarm In principle circuit .......................................................................... B-19
Figure B-13: Alarm Out principle circuit ....................................................................... B-20
Figure B-14: xRAP-D and xRAP-B shelf DC input power connector pin functions...... B-21
Figure B-15: SHELF alarm connector pin identification ............................................... B-21
Figure B-16: ALARMS connector pin identification ...................................................... B-23
Figure B-17: SHELF EXTERNAL ALARM/CONTROL connector pin identification..... B-28
Figure B-18: RAP connector pin identification ............................................................. B-30
Figure B-19: CONTROL CONNECTION connector pin identification.......................... B-31
Figure B-20: 3-pin power connector ............................................................................. B-34
Figure B-21: 5-pin power connector ............................................................................. B-34
Figure B-22: xRAP-100 SHELF ALARM connector pin identification .......................... B-35
Figure B-23: xRAP-100 ALARM IN/OUT connector pin identification ......................... B-36
Figure B-24: miniRAP shelf DC input connector pin functions .................................... B-40
Figure B-25: SEVERITY IN alarm connector pin identification .................................... B-40
Figure B-26: SEVERITY OUT alarm connector pin identification ................................ B-41
Figure C-1: Connections for 16- to 32-channel expansion ........................................... C-2
Figure D-1: Typical rack layout with a patch panel ....................................................... D-4
417006-2304-0H3-B02
List of Tables
Table 1-1:
Table 4-1:
Table 4-2:
Table 4-3:
Table 4-4:
Table 4-5:
Table 4-6:
Table 4-7:
Table 4-8:
Table 5-1:
Table 6-2:
Installation Data for XDM-500 I/O Cards and Associated Modules ...... 6-6
Table 6-3:
Table 8-1:
Table 8-2:
Table 8-3:
Table 8-4:
Table 8-5:
Table 8-6:
Table 9-1:
Table 9-2:
Table 9-3:
Table 9-4:
Table 9-5:
General troubleshooting procedures for optical
transceiver plug-ins ...................................................................................................... 9-15
Table 9-6:
Table 9-7:
Table 9-8:
Table 9-9:
Table 9-10:
Table 9-11:
Table 9-12:
Table 9-13:
417006-2304-0H3-B02
xi
List of Tables
Table 9-14:
Table 9-15:
Table 9-16:
Table 9-17:
Table 9-18:
Table 9-19:
Table 9-20:
Table 9-21:
Table 9-22:
Table 9-23:
Table 9-24:
Table A-1:
Table A-2:
Table A-3:
Table A-4:
Table A-5:
Table A-6:
Table A-7:
Table A-8:
Table A-9:
Table A-10:
Table A-11:
Table B-1:
Table B-2:
Table B-3:
Table B-4:
Table B-5:
Table B-6:
Table B-7:
Table B-8:
Table B-9:
M2_84B interface module, 14-tributary connector
pin assignment ............................................................................................................. B-12
Table B-10:
Table B-11:
Table B-12:
Table B-13:
SHELF EXTERNAL ALARM/CONTROL connector
pin assignment ............................................................................................................. B-28
Table B-14:
xii
417006-2304-0H3-B02
List of Tables
Table B-15:
Table B-16:
Table B-17:
Table B-18:
Table B-19:
Table B-20:
Table B-21:
Table E-1:
Table E-2:
417006-2304-0H3-B02
xiii
List of Tables
xiv
417006-2304-0H3-B02
Overview
The XDM-500 Installation and Maintenance Manual (IMM) describes how to
set up, configure, and install the XDM-500 and its components and accessories.
The manual also provides task-oriented instructions for testing, troubleshooting
hardware-related problems, and replacing hardware components (cards,
modules, accessories).
Intended Audience
This manual is intended for installation and other qualified service personnel
responsible for installing the system and its accessories.
The instructions require you to understand and follow the safety practices
included here, as well as any applicable national regulations and those enforced
at your site. They also require that you understand the physical, optical, and
electrical requirements of the installation site.
417006-2304-0H3-B02
xv
Document Organization
This Installation and Maintenance Manual contains the following information:
Document Conventions
When applicable, this manual uses the following conventions.
Convention
Indicates
Example
Bold
Italics
xvi
417006-2304-0H3-B02
Related Documentation
The following publications may be of assistance to you in the installation and
commissioning processes. Some of these documents present information
supplied in this installation manual in greater or lesser detail.
417006-2304-0H3-B02
xvii
Obtaining Technical
Documentation
To obtain technical documentation related to ECI products, contact:
ECI Ltd.
Documentation Department
30 Hasivim St.
Petach Tikva 49130
Israel
Fax: +972-3-9268060
Email: techdoc.feedback@ecitele.com
Technical Assistance
The configuration, installation, and operation of the XDM-500 and its
operation in a network are highly specialized processes. Due to the different
nature of each installation, some planning aspects may not be covered in this
manual.
If you have questions or concerns about your network design or if you require
installation personnel to perform the actual installation process, ECI maintains
a staff of design engineers and highly trained field service personnel. The
services of this group are available to customers at any time.
If you are interested in obtaining design assistance or a network installation
plan from ECI's Customer Support team, contact your ECI sales representative.
With any support related issues, technical or logistic, contact the ECI Customer
Support center at your location or our central customer support center action
line at:
Telephone
+972-3-9266000
Telefax
+972-3-9266370
on.support@ecitele.com
xviii
417006-2304-0H3-B02
1
Installing XDM-500: Before
You Start Safety Guidelines
In this chapter:
Overview ......................................................................................................... 1-1
Warning Definition .......................................................................................... 1-2
Qualified Personnel Warning .......................................................................... 1-3
Installation Warning ........................................................................................ 1-4
General Safety Requirements .......................................................................... 1-5
Jewelry Removal Warning .............................................................................. 1-6
Grounding Requirements ................................................................................. 1-7
Power Supply Requirements ......................................................................... 1-11
TUV Statutory Warnings and Requirements ................................................. 1-17
ITU-T/Telcordia Statutory Warnings and Requirements .............................. 1-19
Laser Safety Requirements ............................................................................ 1-21
Protection Against Electrostatic Discharge ................................................... 1-26
Environmental and Health Concerns ............................................................. 1-31
Overview
This chapter describes the XDM safety guidelines. The safety rules and
warnings in this chapter must be read before beginning any platform
installation or maintenance work. These safety guidelines must be adhered to
carefully.
WARNING: XDM equipment (the "XDM equipment" or the
417006-2304-0H3-B02
1-1
Danish
Dutch
Finnish
French
German
Italian
Portuguese
Spanish
Swedish
Warning Definition
WARNING: This symbol means danger. You are in a situation that
could result in severe bodily injury. Before you work on any
equipment, be aware of the potential electrical hazards and become
familiar with accident prevention measures.
1-2
417006-2304-0H3-B02
que a sua sade corre srios riscos. Antes de comear a trabalhar com o
equipamento, verifique o risco potencial de choque elctrico e
familiarize-se com as medidas de preveno de acidente.
417006-2304-0H3-B02
1-3
Installation Warning
WARNING: Before you connect the equipment to a power source, read
the installation information in this guide.
1-4
417006-2304-0H3-B02
Note that the equipment racks and XDM platforms are suitable for
mounting on concrete or other noncombustible surfaces only.
Ensure that the maximum working temperature does not exceed 50C.
Avoid contact with high voltage sources when installing platforms, cards,
and modules.
Make sure you are familiar with the warning signals and labels affixed to
the equipment, and strictly observe the procedures to avoid the indicated
hazards.
417006-2304-0H3-B02
1-5
1-6
417006-2304-0H3-B02
Grounding Requirements
All equipment, including XDM platforms, ancillary units, and equipment from
other vendors, must be properly grounded at all times. Good grounding is
necessary to protect personnel and equipment, minimize noise, and allow the
discharge of accumulated static charges to earth.
Proper operation of the XDM equipment requires that the positive supply line
be connected to the common ground (CGND) of the site at the power source, in
accordance with ETS300132-2.
WARNING: When installing the equipment, the ground connection must
always be made first and disconnected last.
417006-2304-0H3-B02
1-7
Figure 1-1: Optical rack grounding bar and rack frame grounding post
1-8
417006-2304-0H3-B02
A connection must be made between the rack grounding bar and the site
grounding bar in compliance with TUV/ETSI recommendations. For example,
grounding may be completed by means of a copper cable with green/yellow
insulation having the same diameter as the power feeding cables or thicker, and
as short as possible. A length of appropriate gauge grounding cable is included
with the platform accessories. A different connection bar may also be used, as
long as the grounding connection is in compliance with TUV/ETSI
recommendations. The rack grounding stud is connected to the rack grounding
bar by means of a metal panel. These rack grounding connections are
highlighted in the following figure.
Figure 1-2: Grounding the optical rack to the site grounding bar
417006-2304-0H3-B02
1-9
1-10
417006-2304-0H3-B02
Platform
Circuit breaker
rating (A)
XDM-40
20
AM1R-B3-AC-21-K-A-20-2
XDM-400
25
AM1R-B3-AC-21-K-A-25-2
XDM-450
16
AM1R-B3-AC-21-K-A-16-2
XDM-500
30
AM1R-B3-AC-21-K-A-30-2
XDM-1000
55
AM1R-B3-AC-21-K-A-55-2
XDM-2000
60
AM1R-B3-AC-21-K-A-60-2
XDM-3000
50
AM1R-B3-AC-21-K-A-50-2
417006-2304-0H3-B02
1-11
DC Power Warnings
WARNING: Follow this wiring sequence when connecting power:
ground to ground, positive lead to +RTN terminal, and negative lead to 48 V terminal. To disconnect power, perform the sequence in reverse
order. Always connect the ground wire first and disconnect it last.
1-12
417006-2304-0H3-B02
till jord, positiv sladd till +RTN-terminalen och negativ sladd till -48 Vterminalen. Utfr dessa steg i motsatt ordning nr du kopplar frn
strmmen. Jordsladden br alltid kopplas in frst och kopplas ur sist.
polarity, as reversed polarity may trip the circuit breaker or damage the
equipment.
417006-2304-0H3-B02
1-13
WARNUNG: Achten Sie bei verseilten Kabeln darauf, dass keine Litzen
aus den Gleichstromanschlssen hervorstehen.
AVVERTENZA: Se si utilizzano cavi a connettori multipli, assicurarsi
che nessun cavo sporga dai terminali dell'alimentazione CC.
1-14
417006-2304-0H3-B02
417006-2304-0H3-B02
1-15
1-16
417006-2304-0H3-B02
Warning Label
The following warning label is affixed alongside the XDM power input
connectors and the RAP circuit breakers.
417006-2304-0H3-B02
1-17
1-18
417006-2304-0H3-B02
ITU-T/Telcordia Statutory
Warnings and Requirements
This section outlines the ITU-T and Telcordia statutory warnings and
requirements applicable to XDM platforms. The source for these requirements
can be found in IEC 60950-1/3.2.1.2.
417006-2304-0H3-B02
1-19
1-20
417006-2304-0H3-B02
Laser Information
See the XDM System Specification for information regarding the laser
transmitters of the various optical cards.
417006-2304-0H3-B02
1-21
1-22
417006-2304-0H3-B02
417006-2304-0H3-B02
1-23
1-24
417006-2304-0H3-B02
If the connections to the amplifiers have not yet been made, for
example, during platform installation activities, always install
protective caps on the amplifier optical connectors.
When the time comes to connect fibers to the amplifiers, first make sure
the platform is not powered and cannot be powered while you work on
it.
417006-2304-0H3-B02
1-25
1-26
417006-2304-0H3-B02
General
Most types of electronic equipment, assemblies, and components can be
damaged by ESDs. An ESD between two objects occurs when an object
carrying static electrical charges touches, or is brought near the other object.
Static electrical charges appear as a result of friction between surfaces of
insulating materials or separation of two such surfaces, and may also be
induced by electrical fields. Routine activities, such as walking across an
insulating floor, friction between garment parts, friction between objects, and
so on, can easily build up charges to levels that may cause damage, especially
when humidity is low.
In many cases, the buildup of charges can be avoided by using special
materials, for example, garments and packaging made of antistatic materials or
materials that have high resistivity but are not insulators.
The best approach to avoiding damage by ESD includes a combination of
means and procedures that:
Personnel Training
During production and assembly, equipment is handled in work spaces
especially prepared and certified to serve as a permanent EPA. However, in
many cases, the environment in which the same equipment is installed or
maintained cannot be assumed to form an EPA with a permanently controlled
boundary.
Therefore, all the work requiring the handling of unprotected ESDS devices
must be considered as field work.
Field work in this context includes activities such as service and maintenance,
installation, site inspection, and commissioning of components and assemblies
classified as ESDS, together with the packing and unpacking activities
associated with such activities.
All the staff involved in field work must be trained to perform field work in the
same way as work performed in permanent EPAs with respect to the material
quality and personal responsibilities, training, labeling, and packaging.
417006-2304-0H3-B02
1-27
The temporary EPA must include temporary controlled work surfaces and/or
flooring capable of providing protection against ESD.
CAUTION: The temporary EPA must be constructed in a
A means of equipotentially bonding the operator and any work surface and
flooring to ground must be used. For this purpose, the work surface and wrist
straps must be bonded, either to a designated ground bonding point or to the
Equipment being serviced, as shown in the following figure.
Whenever available, the main ground serves as the ESD grounding facility.
WARNING: While the operator is within the temporary EPA,
the minimum value of resistance used for bonding to ground
must limit the current to ground produced by voltages
accessible to the operator to limits specified as safe by the
applicable regulations (see, for example, CECC 00 015).
1-28
417006-2304-0H3-B02
417006-2304-0H3-B02
1-29
1-30
If the extent of the temporary work area is such that the operator needs to
walk and move within that area, the floor must be capable of providing
protection against ESD.
The field service operator must ensure that the materials and tools
necessary to maintain and control the temporary EPA are available at the
place of the field work at service time.
All tools intended for use within the EPA must, as far as is practical, be so
constructed that they do not generate or hold an induced electrostatic
charge.
417006-2304-0H3-B02
Adequate record-keeping
Monitoring output for defects, with appropriate and corrective action where
necessary
417006-2304-0H3-B02
1-31
1-32
417006-2304-0H3-B02
417006-2304-0H3-B02
1-33
1-34
417006-2304-0H3-B02
2
Introduction to the XDM
Platform
In this chapter:
Overview ......................................................................................................... 2-1
XDM Product Lines......................................................................................... 2-2
Features and Functions .................................................................................... 2-3
Implementation Principles ............................................................................... 2-4
Cards and Modules .......................................................................................... 2-5
XDM-500 ........................................................................................................ 2-7
Overview
ECI's XDM is a family of next-generation converged optical networking
platforms that integrate all the transport functions of a complete Point of
Presence (POP) in a single shelf-size element. The XDM easily accommodates
the growing demand for bandwidth mainly driven by emerging data
applications, while maintaining the compatibility and the enhanced flexibility
needed to transport all types of traffic, including voice, ATM, Ethernet, IP, and
data.
Advances in access equipment bring increased bandwidth to the service-centric
customer, and regional networks are fleshing out capacity with Wavelength
Division Multiplexing (WDM). Connectivity has therefore become the
bottleneck in service provisioning.
417006-2304-0H3-B02
2-1
The new XDM concept combines the wealth of bandwidth offered by WDM;
the manageability, fast protection, and restoration times of Time Division
Multiplexing (TDM); the enhanced connectivity and availability of cross
connects (DXC); and the efficient transport of Ethernet, IP, and ATM traffic.
Moreover, it provides an ideal platform for migration from ring to mesh
networks. These capabilities result in a single powerful, flexible, and highly
intelligent platform, with unparalleled basic functionality.
XDM platforms are equipped with high capacity nonblocking matrixes that
enable operators to build extremely flexible and transparent optical networks.
2-2
417006-2304-0H3-B02
Add and drop of any signal (SDH, PDH, data, wavelength) at any node
using a single shelf.
High Order (HO) and Low Order (LO) transmission paths available for
both high-order and low-order subnetworks, with a high-capacity matrix
that maintains LO connectivity.
417006-2304-0H3-B02
2-3
Full compliance with applicable ITU-T and Telcordia standards for optical
equipment and safety standards.
Implementation Principles
The XDM platforms have a fully modular design based on a redundant routing
core implemented as a proprietary cross-connect matrix surrounded by I/O
ports located on plug-in I/O cards. The function of the I/O cards is to provide
interfaces to the various types of signals that can be transported by the
platforms. Internally, all the I/O cards exchange information with the routing
core using a proprietary format that does not depend on the characteristics of
the external interfaces.
The use of a single proprietary format for all the information flowing through
the XDM results in a highly flexible system that supports a wide range of
applications and can easily be expanded to suit virtually any customer need.
Moreover, support for new signal formats can be added simply by developing
new I/O cards. This protects customer investment in the XDM platform against
obsolescence, and ensures cost-effective upgrade paths.
The XDM platforms consist of the following main subsystems:
2-4
Traffic processing
Routing core
Power feed
Cooling
417006-2304-0H3-B02
All the subsystems are modular and implemented as plug-in cards. Except for
the traffic interfaces, all the subsystems are fully redundant and/or are
implemented as distributed functions with no single point of failure, thereby
ensuring the high availability needed to meet the stringent requirements of
telecom operators.
Moreover, XDM platforms are designed to permit live insertion and hot
swapping of cards and modules, and their software can be downloaded from a
remote location. In addition to maintenance efficiency, these characteristics
enable non-traffic-affecting in-service upgrading and expansion of system
capabilities.
MPLS and Ethernet cards: Data I/O (DIO and DIOB) cards for Layer 1
Ethernet (GbE/FE) services; Ethernet Interface Switch (EIS) cards for
Layer 2 Ethernet services; and MPLS Carrier-Class Switch (MCS) cards
for full MPLS as well as Carrier Ethernet services.
ATM Traffic Switch (ATS) cards for direct processing of ATM traffic,
addressing the requirements of 3G cellular networks. The ATS is a singleslot card that concentrates Node B traffic into VC-4s or large Inverse
Multiplexing over ATM (IMA) groups.
Optical (TRP and CMBR) cards: 10 GbE LAN, GbE, STM-256, STM-64,
STM-16, OTU1, OTU2, OTU3, 1G, 2G, 10G Fiber Channel, any rate.
417006-2304-0H3-B02
2-5
2-6
417006-2304-0H3-B02
XDM-500
The XDM-500 is a compact multiservice Packet-OTS with integrated all-range
WSS ROADM, for high capacity aggregation of TDM and Ethernet/MPLS
services over optical infrastructure in metro and regional networks. The
XDM-500 is optimized for the metro-edge, where it collects multiple services
and delivers them to the COs and POPs in the core. The XDM-500 provides
traditional broadband services as well as sophisticated optical capabilities such
as multidegree ROADM technology and highly advanced data services such as
adaptive rate GbE, sophisticated Layer 2 Ethernet, and Packet over SDH (PoS).
It can be used either as a simple ADM or as a multi-ADM/TM for distributed
ring cross connectivity.
The XDM-500 compact shelf is located in a 285 mm deep, 450 mm wide, and
725 mm high equipment cage. Platform components are arranged as follows:
Six slots (IC1 to IC6) flexibly allocated to I/O cards and/or transponders
(depending on the configuration)
Two slots (X1 and X2) allocated to the HLXC or XIO matrix cards
One slot (C3) allocated to the MECP card, for connecting the OHA and
OW interfaces to the active xMCP card
417006-2304-0H3-B02
2-7
2-8
417006-2304-0H3-B02
3
XDM-500 Installation
Overview
In this chapter:
Overview ......................................................................................................... 3-1
Preliminary Preparations ................................................................................. 3-2
Stages of a Typical Installation ....................................................................... 3-3
Outline of Installation Procedure ..................................................................... 3-5
Overview
The following sections provide general instructions for the installation of the
XDM-500 and auxiliary equipment.
The procedures for equipment replacement and upgrades are similar to those
described for installation of the equipment. When relevant, notes regarding live
replacement or upgrade are inserted in the installation procedure descriptions.
This manual contains important information that will help you carry out a safe
and trouble-free installation, including:
Safety guidelines
417006-2304-0H3-B02
3-1
Preliminary Preparations
The installation procedures provided here assume that:
All technical personnel have read, understood, and are complying with the
safety guidelines in Before You Start/Safety Guidelines (page 1-1).
The sites in which the installation procedures are carried out comply with
the requirements listed in Site Preparation and Rack Installation (page 4-1).
3-2
417006-2304-0H3-B02
CAUTION:
417006-2304-0H3-B02
3-3
3-4
417006-2304-0H3-B02
8. Route the optical fibers among the connectors of the equipment installed in
each rack, in accordance with the site installation plans (see "Optical Fiber
and Cable Installation and Routing" page 7-1).
9. Connect coaxial and multipair cables to the electrical interface modules of
each XDM shelf installed in the rack, in accordance with the rack
installation plans (see "Connecting Traffic Cables to Electrical Interfaces"
page 7-17).
10. Connect management cables between the equipment installed in the racks
and the management station, in accordance with the site installation plans
(see "Connecting Management Cables" page 7-22).
417006-2304-0H3-B02
3-5
11. Connect power and alarm monitoring cables from the rack power
distribution and alarm panels to each equipment unit installed in the rack, in
accordance with the rack installation plans.
12. Connect power, alarm, and traffic cables to the new equipment racks, in
accordance with the site operational procedures.
13. Mount the door or doors on the XDM platform, and close it (see also Deep
doors vs. standard doors (page 4-3)). Note that this step only applies to
closed-cabinet installations, and may not be relevant at your site.
14. Perform power-on and initialization procedures.
15. Complete any relevant commissioning tests (page 8-1).
16. Install the LCT-XDM and element management station (EMS-XDM) and
configure the equipment. For more information, refer to the EMS-XDM
User Manual and the LCT-XDM User Manual.
3-6
417006-2304-0H3-B02
4
Site Preparation and Rack
Installation
In this chapter:
Overview ......................................................................................................... 4-1
Tools and Test Equipment ............................................................................... 4-8
Unpacking and Visual Inspection .................................................................... 4-9
XDM Rack Installation Options .................................................................... 4-10
Cable and Fiber Preparation .......................................................................... 4-23
Installing Equipment Racks ........................................................................... 4-37
Installing Ancillary Units in Racks ............................................................... 4-44
Overview
The following sections describe the conditions required for installing the
equipment at the site, including site preparation, power sources, rack
installation, preparing cables and fibers, installing ancillary units and more.
Site Preparation
Perform a preliminary survey of the installation site, taking into consideration
the following issues:
417006-2304-0H3-B02
4-1
Environmental Requirements
The following environmental conditions are applicable to XDM equipment and
must be provided at the installation site.
Table 4-1:
Environmental requirements
Parameter
Compliance requirements
Electromagnetic interference
Temperature
4-2
Equipment type
Height
(mm)
Width
(mm)
Depth
(mm)
Max. weight
(kg)
XDM-500
725
450
285
60
xRAP-100
133
445
185
10
miniRAP
90
445
150
2.8
133
445
185
9.5
xRAP-HP (EOL)
125
450
120
10
FST
44.5
440
240
Heat buffer
70
437
285
Cable guide
100
450
80
417006-2304-0H3-B02
However, the new design does not comply with ETSI rack standards as it
bulges beyond the depth allowed for equipment in ETSI racks. This prevents
the user from closing the rack door. In addition, the new design presents
thermal restrictions because airflow is less effective. It is thus less
recommended at sites with heavy power consumption.
417006-2304-0H3-B02
4-3
4-4
Type of
interface
Short boot
sufficient to
close
standard
XDM door
Compliance
with
standard
bending
angle
Deep door
required with
attenuators
on XDM cards
Yes
Yes (with
short boot)
Yes
Yes (with
short boot)
Yes
Yes (with
short boot)
Yes
Yes (with
short boot)
No
Yes
No
Combiners
Yes
Yes (with
short boot)
Yes
Yes (with
short boot)
Transponders
Yes
Yes (with
short boot)
Yes
Yes (with
short boot)
417006-2304-0H3-B02
Door Installation
For greater convenience, XDM platforms are shipped without any doors
attached. Doors of the appropriate type as selected in the site specifications are
packaged separately from the basic platform, and attached on site during
platform installation.
To install a platform door:
1. Lift the door and hold it carefully in front of the platform.
2. Align the holes on the hinge side of the door with the hinge posts on the
side of the platform.
3. Gently slide the door into place, with the hinge posts fitting smoothly into
the door holes.
4. The door should swing open and close easily.
To remove a platform door, simply open the door and lift the door gently from
the hinge posts.
The XDM-3000 platform is designed with two doors, one for the upper half of
the platform and one for the lower half. This design ensures that the door size
and weight is manageable when installing or removing a door, even though the
XDM-3000 platform is larger than the other platforms in the XDM product
line. When installing a new XDM-3000 platform, simply repeat the door
installation procedure for both platform doors.
Physical Location
WARNING: XDM platforms are intended for installation
only in restricted access areas.
Choose the physical location of the XDM equipment, taking the following
aspects into consideration:
417006-2304-0H3-B02
4-5
exceeds -72 VDC, all xINFs are shut down and the platform
is switched off.
The following table lists the maximum allowed power consumption data for the
XDM-500 platforms, the required xRAP type, and the supply line protection
circuit breaker.
Table 4-4:
Shelf type
FCU
Circuit breaker
XDM-500
950 W
Regular or HP
30A
HP, B, or D
The actual power consumption for each shelf is limited by the client power
infrastructure. Limiting factors may include the client power supply capacity,
circuit breaker size, and type of backplane, xRAP, FCU, and INF.
Beginning with V7.2, platform power supply limitations are enforced by the
EMS-XDM management software to protect against over-demand. Upper
bound limits for maximum platform power usage are defined through the
management configuration variables and enforced through software protection.
The preceding table lists maximum power consumption settings, based on a
typical combination of XDM-500 component types. The actual maximum
power limitation for each specific installation is calculated as follows:
1. The EMS-XDM identifies the backplane, xRAP, FCU, and INF type
automatically.
2. The circuit breaker size must be manually identified for the EMS-XDM by
a system administrator (by setting a configuration variable). By default,
circuit breakers for the XDM-500 are assumed to be 25A unless
explicitly defined otherwise. The software by default limits the maximum
XDM-500 shelf power consumption to 950 W.
3. The EMS-XDM calculates a tentative maximum platform power
capacity value for this platform, based on the backplane, xRAP, FCU, INF,
and circuit breaker information.
4-6
417006-2304-0H3-B02
The XDM Element Management (EMS-XDM) station and the test equipment
are powered from an AC source; their nominal supply voltage may range from
100-230 VAC, 50/60 Hz.
Typical power consumption for the XDM-500 is 720 W. Typical power
dissipation of the XDM-500 shelf is 2460 Btu/hr.
Power consumption can range up to a maximum of 950 W, depending on the
installed components and platform configuration, as explained in this section.
Maximum power dissipation of the XDM-500 shelf is 3240 Btu/hr.
For more information about power consumption requirements, please refer to
the XDM System Specifications. Power consumption is monitored through the
management software.
WARNING: When replacing circuit breakers, observe the following
precautions:
For continued protection against risk of fire, replace only with a
circuit breaker of the same type and rating.
Disconnect power before changing a circuit breaker.
417006-2304-0H3-B02
4-7
Tools for coaxial cables type NCX1 (typically include cable stripper, nipper
(cutter for center contact), and die)
Tools for the assembly of DIN 1.0/2.3 coaxial connectors on coaxial cables
(typically include cable stripper, center contact crimp tool (blue), and crimp
tool for outer contact)
Tools for the preparation of optical patch cords (including fiber splicing
and optical connector attachment)
4-8
417006-2304-0H3-B02
3. Search the shipping boxes for any additional small items that may be
present.
417006-2304-0H3-B02
4-9
4. Open each of the card packages (shipped separately from the XDM
platforms in which they will be installed) for inspection, but do not remove
the cards.
To protect the cards against possible damage, keep the cards in their
protective package until they can be inserted in the platform.
5. Check the contents of the shipping boxes against the packing list attached
to each box. If you detect any damaged or missing parts, notify the project
manager and/or your local ECI representative.
4-10
Removable rear and side panels for tidy routing and efficient
maintenance of all rack cables, including:
Control cables
Power cables
Two channels on the racks front rails for routing up to 400 (ETSI A) or
800 (optical rack) optical fibers.
Open frame top and bottom for easy routing of cables from suspension
floors and/or ceiling ladders.
Perforated door for free air flow to the installed equipment (see
Environmental Requirements (page 4-2)).
Front door for left or right opening mounting.
417006-2304-0H3-B02
Type
Height
Width
Depth
Available space
Optical Rack
2200 mm
600 mm
300 mm
ETSI A
2200 mm
600 mm
300 mm
ETSI A
2600 mm
600 mm
300 mm
ETSI B
2200 mm
600 mm
300 mm
ETSI B
2600 mm
600 mm
300 mm
US
7 ft
(2134 mm)
23 in.
(585 mm)
12 in.
(305 mm)
44U
(6.5 ft/1960 mm)
US
7 ft
(2134 mm)
19 in.
(483 mm)
12 in.
(305 mm)
44U
(6.5 ft/1960 mm)
ISO 19
7.25 ft
(2200 mm)
24 in.
(600 mm)
24 in.
(600 mm)
47U
(6.85 ft/2089 mm)
417006-2304-0H3-B02
4-11
Equipment type
Height (U)
Height (mm/in.)
XDM-40
256/10.1
XDM-450
8.5
374/14.72
XDM-500
18
800/31.5
XDM-1000
26
1100/43.3
XDM-2000
19
845/33.3
XDM-3000
35
1550/61
PRAP
133/5.25
xRAP-B/D
133/5.25
xRAP-HP
2.8
125/4.92
xRAP-100
133/5.25
miniRAP
90/3.5
Spooler
2.8
125/4.92
FST
44.5/1.75
90/3.5
Heat buffer
70/2.7
Cable guide
120/4.7
XDM systems can be installed in any of the racks listed in XDM Rack
Installation Options (page 4-10).
4-12
417006-2304-0H3-B02
Optical Rack
ECI offers a special optical rack designed to accommodate the potentially large
number of fiber cables that may be required for the installation of XDM
equipment. An added advantage of the optical rack is easy access to all the
components and cables during installation, maintenance, and when adding new
cards and modules. The following figure shows a general view of an optical
rack.
417006-2304-0H3-B02
4-13
The rack has two side covers that cover the two cable conduits. These covers
are normally installed when using standalone racks or when the rack is the end
unit in a group. When two racks are installed side by side, the covers are
removed.
NOTE: When necessary, the rear cover of the rack can also
be removed.
In addition to the wide cable conduits, two easily accessible fiber channels are
located at the rack sides in front of the conduits.
ETSI A Rack
ECI offers a special ETSI rack with improved cable routing features. The
following figure shows a general view of a standalone rack with its door
closed.
NOTE: The rack is normally supplied with the door opening
4-14
417006-2304-0H3-B02
An added advantage of the type A ETSI rack is easy closure of the rack door
even when the XDM shelf is equipped with an extended door (the extended
door occupies 22.3 mm more than the standard door - see Deep doors vs.
standard doors (page 4-3)). The only requirement is to ensure that the extended
door is not located directly behind the door lock (it can be higher or lower than
the lock).
417006-2304-0H3-B02
4-15
The following figure shows the same rack with the door open.
The rack has two side covers that cover the two cable conduits at the rack sides.
These covers are normally installed when using standalone racks or when the
rack is the end unit in a group. When two racks are installed side by side, the
covers are normally removed.
NOTE: When necessary, the rear cover of the rack can also
be removed.
4-16
417006-2304-0H3-B02
In addition to the wide cable conduits, two fiber conduits are located at the rack
sides before the cable conduits. To protect fibers that have to cross from one
rack side to the other, two additional fiber conduits (the upper and lower
conduits) are provided.
The side fiber conduits can easily be reached. The front side of the right
conduit is exposed when the door is opened, and the left conduit is exposed
when the side panel is opened. (To open the side panel, turn the release handles
on the upper and lower fiber conduits.)
Environmental Considerations
Observe the following guidelines when installing the XDM-500 in racks:
1. Free airflow through the rack must be guaranteed at all times.
2. XDM-500 shelves can be installed in open or closed (with door) racks.
When installed in a closed rack, the door must be perforated. An example
of a rack with a perforated door is the ETSI A rack shown in the following
figure.
3. Always install the first XDM-500 platform in the lower part of the rack,
leaving a space of at least 1U from the bottom of the rack.
4. In mixed (horizontal and vertical airflow) equipment installations, always
install the equipment with the horizontal airflow in the lower part of the
rack, and the equipment with the vertical airflow above it.
5. Leave a space of at least 1U between the upper accessory of the XDM-500
and the next platform.
6. Leave as much space as possible between the racks cable supports and the
XDM-500 sidewalls.
7. Always consider the platform airflow requirements when organizing the
cable and fiber routes near the XDM-500 sidewalls.
417006-2304-0H3-B02
4-17
4-18
417006-2304-0H3-B02
Suitable arrangements are made for routing the cables connecting to the
equipment units installed in the rack. This aspect is particularly important
in installations handling E1 tributary lines (connected to M2_21 and
M2_84 interface modules), because a single XDM platform can easily
handle hundreds of E1 tributaries.
The following multiple shelf installation options have been evaluated by ECI
for compliance with the requirements listed above:
2600 mm ETSI racks can accommodate at least two XDM shelves within
the XDM-1000 product line. However, to install two XDM-1000 shelves, it
is necessary to install the xRAP using extendable installation rails.
One 2200 mm ETSI rack, or one 7 ft. (2134 mm) rack, can accommodate
two XDM-500 or XDM-2000 shelves. One XDM-1000 shelf and one
XDM-500 or XDM-2000 shelf can also be installed in this type of rack, but
this configuration requires a special version of the xRAP.
You can find typical rack layouts for several equipment configurations in
Typical XDM Installations in Racks (page 4-20). Contact ECI Customer
Support team or your ECI sales representative for help in meeting your specific
installation requirements.
417006-2304-0H3-B02
4-19
4-20
417006-2304-0H3-B02
The following figure shows one XDM-1000 shelf and one XDM-500 shelf
installed in a 2600 mm rack.
417006-2304-0H3-B02
4-21
4-22
417006-2304-0H3-B02
The following main types of cables are required for XDM installations:
417006-2304-0H3-B02
4-23
Grounding Cables
WARNING: To prevent possible damage to XDM
Equipment installed in a rack is bonded through the screws used to fasten the
equipment chassis to the frame of the rack, as described in Equipment
Grounding Requirements (page 1-10). Therefore, it is necessary to provide a
reliable low-impedance connection between the rack frame and the site
grounding bus using copper conductors. It is essential that the metal surfaces of
the rack installation elements, including the rack frame, the metal screws, and
the equipment mounting brackets, be completely clean and free of any paint or
any other coating that may impede the grounding connection, to provide
electrical continuity between the equipment and the rack frame. For more
information, see Grounding Requirements (page 1-7).
4-24
417006-2304-0H3-B02
A connection must be made between the rack grounding bar and the site
grounding bar in compliance with UL/ETSI recommendations. For example,
grounding may be completed by means of a copper cable with green/yellow
insulation having the same diameter as the xRAP input power cables or thicker.
A length of appropriate 50 mm2 grounding cable is included with the platform
accessories. Grounding cables are connected using two-hole compression lug
terminals on both ends, securely fastened with flat washers, serrated lock
washers, and nuts or bolts, depending on the connection point.
417006-2304-0H3-B02
4-25
The end of the lead connected to the xRAP used in the rack must be terminated
in a lug suitable for the gauge of the lead in use. Typical grounding cable sizes
are as follows.
For the PRAP, xRAP-D, xRAP-B, and xRAP-HP power supply units,
0 AWG (50 mm2/.078 in.2) or thicker cable
4-26
417006-2304-0H3-B02
417006-2304-0H3-B02
4-27
DC Power Cables
NOTE: According to accepted industry standards for
This gauge ensures that the voltage drop across the rack power cable at full
power consumption does not exceed 2 V, even for cable runs up to 30 meters
(99 feet) connected to an xRAP providing power to two XDM platforms.
4-28
417006-2304-0H3-B02
For cable runs not exceeding 20 meters (66 feet), it is sufficient to use
16 mm2 (.025 in.2) copper leads.
For cable runs not exceeding 30 meters (99 feet), it is sufficient to use
25 mm2 (.039 in.2) copper leads.
NOTES:
417006-2304-0H3-B02
4-29
Alarm Cables
When an xRAP unit is installed in the rack, it provides the special interfaces
needed for connecting to the platform alarm interfaces. In this case alarm
indications are carried by the following cables:
External alarm connection cable. One external alarm cable is required for
each rack. This cable carries the alarm indications and monitoring lines of
the rack. One end of the cable is connected to the xRAP, the other end is
open and connects to the client's alarm collecting facility. Three types of
this cable are available:
4-30
417006-2304-0H3-B02
Management Cables
The connection of out-of-band management traffic to an XDM platform is
made to the RJ-45 ETHERNET connectors located on the MECP card.
Each ETHERNET connector is wired as a 10BaseT station port:
Suitable standard Ethernet station cables are available from many sources.
Category 3 or better cables must be used. In any case, the length of the cables
must not exceed the maximum recommended for the cable type and hub port in
use (up to a few dozens of meters or feet).
The connectors designated BITS1 IN/OUT and BITS2 IN/OUT are used
for 1.544 Mbps signals and have balanced 100 interfaces.
The cables used to connect to these connectors are prepared on site, using
cables comprising individually shielded twisted pairs (the same type of pairs
needed for connection to the balanced E1 tributary interfaces).
If the site timing reference distribution subsystem has unbalanced (75 ) G.703
interfaces, a 120 /75 adapter can be supplied for mounting on the
T3_1/T4_1 and T3_2/T4_2 connectors. This permits using coaxial cables
(BT3002 or equivalent) of the same type used for connection to balanced E1
tributary interfaces.
417006-2304-0H3-B02
4-31
Traffic Cables
Traffic cables can be prepared on site. The following table lists the cables and
mating connectors needed for each XDM traffic interface type.
Use only 2 mm optical fibers for optical cables connecting to optical interfaces.
For each optical interface, ECI supplies patch cords with mating optical
connectors already attached to the fiber. Therefore, only the optical termination
on the Optical Distribution Frame (ODF) side, which is installation-dependent,
must be installed on site.
NOTE: ECI recommends using only fibers with short boots
I/O card
Interface type
Interface
unit/module
Cable type
Mating
connector
Qty/card
PIO2_84
E1 balanced
(2.048 Mbps)
M2_84B
Multipair cable
(14 pairs of
shielded 120
twisted pairs)
68-pin SCSI
male
6 cables
----------
----------
M2_84BR
E1 unbalanced M2_84U
(2.048 Mbps)
4-32
2 cables
84 pairs of 75
coaxial cables
BT43 male
6 cables
----------
----------
M2_84UR
2 cables
417006-2304-0H3-B02
I/O card
Interface type
Interface
unit/module
Cable type
Mating
connector
Qty/card
PIO2_21
E1 balanced
(2.048 Mbps)
M2_21B 1
Multipair cable
(14 pairs of
shielded 120
twisted pairs)
68-pin SCSI
male
2 cables
E1 unbalanced M2_21U 2
(2.048 Mbps)
21 pairs of 75
coaxial cables
BT43 male
2 cables
E3 and DS-3
(34/45 Mbps)
M345_16BT
---------M345_16DI
16 pairs of NCX
coaxial cables
BT43 male
---------DIN 1.6/5.6
mm male
2 cables
(multi-coax)
M345_8BT
---------M345_8DI
8 pairs of NCX
coaxial cables
BT43 male
---------DIN 1.6/5.6
mm male
---------BNC male
1 cable
(multi-coax)
M1_16BT
------------M1_16DI
16 pairs of NCX
coaxial cables
BT43 male
------------DIN 1.6/5.6
mm male
2 cables
(multi-coax)
M1_8BT
------------M1_8DI
8 pairs of NCX
coaxial cables
BT43 male
------------DIN 1.6/5.6
mm male
1 cable
(multi-coax)
M1_16SFP
and ETR
electrical SFP
32 single NCX
coaxial cables
PIO345_16
PIO345M_16
---------M345_8BN
SIO1&4
SIO1&4M
STM-1
electrical
SIO1&4B
STM-1
electrical
SIO1&4
SIO1&4M
4 pairs of fiber
patch cords (one
pair per interface)
LC
8 fibers
1 pair of fiber
patch cords per
interface
LC or SC
male 3
4 fibers
1 pair of fiber
patch cords per
interface
LC
32 fibers 5
OTR_S3BD
OTR_S5BD
OTR_L3BD
OTR_L5BD
1 pair of fiber
patch cords per
interface
LC
16 fibers 6
SIO1&4B
(with
M1_16SFP) 4
417006-2304-0H3-B02
4-33
7
8
I/O card
Interface type
SIO1&4B
(without
M1_16SFP)
Interface
unit/module
Cable type
Mating
connector
Qty/card
1 pair of fiber
patch cords per
interface
LC
32 fibers 7
SIO16
SIO16M
STM-16
optical
OM16_1
OM16_1SFP
1 pair of fiber
patch cords per
interface
LC or SC
male 8
4 fibers
SIO16_2B
SIO16_4B
STM-16
optical
OTR16_I3
OTR16_S3
OTR16_L3
OTR16_L5
OTR25_AVxx
OTR25_ABxx
OTC25_PSxx
1 pair of fiber
patch cords per
interface
LC male
4 fibers
(SIO16_2B)
8 fibers
(SIO16_4B)
SIO64
SIO64M
SIO64MF
STM-64
optical
OM64_1
1 pair of fiber
patch cords per
interface
SC male
2 fibers
SIO64B
STM-64
optical
OTR64_PI3
OTR64_PS5
OTR64_AL5
OTR10_ASxx
OTX10_ALxx
1 pair of fiber
patch cords per
interface
LC male
2 fibers
SIO164
STM-16/
OTU1 optical
OMSC16_4
1 pair of fiber
patch cords per
interface
LC male
8 fibers
STM-64
OMTX10_S
2 fibers
STM-64/
OTU2 optical
OMTX10
OMTX10_EF
2 fibers
DIO1_61
STM-16
optical
DOM16_I3
1 pair of
single-mode fiber
patch cords
DIO1_40,
DIO1_61 and
DIO1_80
Short-haul
GbE optical
OMGE-1 (SX)
Long-haul
GbE optical
OMGE-1
(LX, ZX)
1 pair of
single-mode fiber
patch cords per
interface
LC male
2 fibers
8, 12, or
16 fibers
4-34
417006-2304-0H3-B02
I/O card
Interface type
Interface
unit/module
Cable type
EIS2_8, EIS8_8,
EIS2_14
Short-haul
GbE optical
OMGE-1 (SX)
Long-haul
GbE optical
OMGE-1
(LX, ZX)
1 pair of
single-mode fiber
patch cords per
interface
Electrical
(1000BaseT,
100BaseT,
10BaseT)
ME_8
---------ME_14
8 cables
---------14 cables
Short-haul
GbE optical
OMGE-1 (SX)
8 pairs
DIOB
MCS5
MCS10
ME16
Mating
connector
Qty/card
8, 12, or
16 fibers
1 pair of
single-mode fiber
patch cords per
interface
UTP 4-pairs with
overall shield
RJ-45 male
16 cables
MCS30_X10G
1 pair of single
mode, or multi
mode (depends on
the transceiver
type) fiber patch
cords
LC male
2 fibers
ACP1000
Electrical
(10BaseT,
100BaseT)
Not applicable
RJ-45 male
(10-pin)
up to
4 cables
Aurora-G
DCN 10/100
Ethernet
management
port
Not applicable
Category 5
shielded straight
through cable
(STP)
RJ-45 male
1 cable
2 GbE
Ethernet ports
9/125 m single
mode duplex fiber
pair
or
62.5/125 m
multimode duplex
fiber or simplex
fiber pair
LC male
1 cable per
port
Electrical
1000BaseT SFP
ETGBL
RJ-45 male
1 cable per
port
417006-2304-0H3-B02
4-35
XIO192
(I/O section)
Interface type
Interface
unit/module
Cable type
Mating
connector
Qty/card
Local PC port
Not applicable
RS-232 shielded
copper null model
cable
DB-9 male
1 cable
1 pair of fiber
patch cords per
interface
LC or SC
male 9
8 fibers
2 fibers
STM-16
optical
OM16_1
OM16_1SFP
2 fibers
STM-16/
OTU1 optical
OMSC16_4
STM-64
OMTX10_S
2 fibers
STM-64/
OTU2 optical
OMTX10
OMTX10_EF
2 fibers
MO_BAC
MO_PAC
MO_BAS
MO_PAS
optical
Not applicable
1 pair of fiber
patch cords per
module
LC
2 fibers
OFA_2
optical
OM_BAC
OM_ILC_23
OM_ILC29
1 pair of fiber
patch cords per
module
LC
4 fibers
OFA_M
optical
1st stage,
2nd stage
1 pair of fiber
patch cords
LX.5
4 fibers
MO_OFA_M
optical
MO_OFA_M
1 pair of fiber
patch cords per
module
2 LC
2 fibers
OFA_R
OFA_RM
OFA_HRM
optical
OM_OFA_R
LX.5
E2000
2 fibers
MO_OFA_FBC
optical
OM_OFA_FBC
1 pair of fiber
patch cords
2 LC
2 fibers
MO_OFA_FHB
C
optical
MO_OFA_FHB
C
1 pair of fiber
patch cords
3 LC
3 fibers
MO_OFA_
PHBC
optical
OM_OFA_P
1 pair of fiber
patch cords
2 LC
2 fibers
OM_OFA_B
1 pair of fiber
patch cords
LC and LX.5
2 fibers
OM_OFA_B
1 pair of fiber
patch cords
LC and LX.5
2 fibers
XIO384F
(I/O section)
MO_OFA_
HBC
optical
1 pair of fiber
patch cords per
interface
LC male
8 fibers
4-36
417006-2304-0H3-B02
I/O card
Interface type
Interface
unit/module
Cable type
Mating
connector
Qty/card
MO_OFA_
MH
optical
1st stage,
2nd stage
1 pair of fiber
patch cords per
stage
1st stage:
2 LC
2nd stage:
LC and LX.5
4 fibers
MO_OFA_MHe
optical
Through
1st stage,
2nd stage
1 pair of fiber
patch cords per
stage
Through
2 LC
1st stage:
2 LC
2nd stage:
LC and LX.5
6 fibers
ETSI use the template shown in Mounting diagrams for ETSI racks
(page 4-38) (diagram a).
23 in. use the template shown in Mounting diagrams for 19 in. and 23
in. racks (page 4-39) (diagram a).
19 in. use the template shown in Mounting diagrams for 19 in. and 23
in. racks (page 4-39) (diagram b).
The marked locations are a helpful guide for positioning the racks.
2. If the installation is located at a site with a raised floor, mark out all cable
entry slots as well.
3. For concrete or wooden floors, mark out all the points designated for
equipment bolting.
417006-2304-0H3-B02
4-37
4-38
417006-2304-0H3-B02
417006-2304-0H3-B02
4-39
4-40
417006-2304-0H3-B02
2. Secure the rack to the overhead cabling trays using the adjustable brackets.
Note that 2200 mm (87 in.) high racks may also be attached to the ceiling;
2600 mm (102.5 in.) racks are generally attached only to the ceiling.
417006-2304-0H3-B02
4-41
Figure 4-13: Optical rack grounding bar and rack frame grounding post
Use a grounding cable that meets the grounding requirements listed in Rack
Grounding Requirements (page 1-8) and prepared appropriately, based on the
instructions in Grounding Cables (page 4-24). The relevant accessory washers
(both flat and serrated), nuts, and bolts are delivered attached to the
corresponding grounding points.
To ground the rack:
1. The rack is delivered with one grounding connection already in place. This
is a metal panel that connects the rack grounding stud to the first grounding
point on the far left side of the rack grounding bar. Verify that this panel is
in place and tightened. The nut over the lug on the rack grounding stud, and
the bolt over the grounding point in the rack grounding bar must both be
tightened with a torque of 450 N cm to 550 N cm.
2. Use the grounding cable to connect the first pair of grounding points on the
left side of the rack grounding bar to the site grounding bar. To secure the
grounding cable lug to the grounding bar, hold the cable lug against the
panel and place the flat washer above the cable lug, followed by the
serrated lock washer. Screw in the bolt to hold everything in place. Tighten
the bolt with a torque of 450 N cm to 550 N cm.
4-42
417006-2304-0H3-B02
Figure 4-14: Grounding the optical rack to the site grounding bar
WARNINGS:
417006-2304-0H3-B02
4-43
Heat buffers. A heat buffer must be installed between each pair of shelves
to minimize the transfer of heat from shelf to shelf. Note that the heat
buffer for XDM-1000, XDM-500, and XDM-2000 shelves occupies 70 mm
(approx. 2U or 2.7 in.). If more room is available, a larger heat buffer of
125 mm (approx. 3U or 5 in.) can be used. If there is not enough space for
a heat buffer, a buffer plate, which occupies 50 mm (approx. 1U or 2 in.),
must be installed.
In general, ancillary units are attached to the rack side rails by four M6 Philips
screws. No preparations are required before installation.
The following sections provide mechanical installation instructions for units
that require additional procedures. Skip sections that are not relevant to your
particular application.
4-44
417006-2304-0H3-B02
417006-2304-0H3-B02
4-45
4-46
417006-2304-0H3-B02
417006-2304-0H3-B02
4-47
Each input power cable consists of two stranded copper leads with a cross
section of 25 (or 50) mm2, one red and the other black. Each lead is terminated
with a two-hole compression lug from the installation parts kit supplied with
the equipment.
If appropriate leads have already been prepared at the prescribed rack location,
make sure that the leads are not connected to any live voltage source before
attaching the lugs.
To prepare a DC power cable:
1. Strip about 22 mm of the red lead jacket.
2. Insert all the lead strands into the lug sleeve.
3. Press at two or three different points on the lug sleeve using an appropriate
crimping tool and die. The recommended tools are Panduit CT-720
crimping tool with CD-720-2 die, Klauke K18 crimping tool with D50 die,
or equivalent.
4. Repeat Steps 1 to 3 for the black lead.
5. Repeat these steps for each DC power cable being used.
To install the xRAP-D:
Attach the xRAP-D to the rack side rails in the top position, and secure it
with the four screws, washers, and nuts supplied in the installation parts kit.
4-48
417006-2304-0H3-B02
417006-2304-0H3-B02
4-49
4-50
417006-2304-0H3-B02
2. Open the two captive screws fastening the xRAP-D front cover and remove
the cover.
Identify the various terminals located on the power source terminal board in
accordance with the following figure. This figure shows the terminals at the
source A side (main); the same board is used at the source B side
(protection).
Note that there are two complete sets of power terminals and circuit
breakers on each side. Separate input power cables from the user's input
power supply feed through the two sets of input power terminals into the
two circuit breakers on the source A side, supplying independent power
sources for up to two XDM shelves. Each circuit breaker feeds into a
separate power output connection for the power cable that connects to the
XDM platform.
Similarly, separate input power cables from the user's input power supply
feed through separate input terminals into the two circuit breakers on the
source B side, and from the circuit breakers feed into the additional power
output connections that provide an optional protective backup power
supply for up to two XDM shelves.
417006-2304-0H3-B02
4-51
The preceding figure portrays the electrical connections on the left side of
the xRAP-D, the side that connects to the user's main power supply for the
XDM shelves being powered. The right side of the xRAP-D contains a
mirror image of the connections illustrated in the preceding figure. The
right side connects to the user's (optional) backup protective power supply
for the shelves.
CAUTION: Before connecting the power leads, make sure to
3. Bring the two leads of one DC source input power cable to the appropriate
xRAP-D opening.
4. Attach the lug of the red lead to the positive stud terminals, marked (+) on
the power terminal board. Note that the xRAP-D works with two sets of
positive terminals, used with two 25 mm2 power cables.
5. Secure the lug using a flat washer, a spring washer, and a nut. Tighten the
nut with a torque of 450 N cm to 550 N cm.
6. Attach the lug of the black lead to the negative stud terminal marked (-) on
the power terminal board. Note that the xRAP-D works with two sets of
negative terminals, used with two 25 mm2 power cables.
7. Repeat Step 6 for the black lead lug.
8. If an additional power source (source B) is used, repeat Steps 3 to 8 for
source B.
9. Route the DC input power cables towards the cable retainers at the rear of
the xRAP-D (see To ground the xRAP-D (page 4-48)), and attach them to
the retainers with cable ties.
4-52
417006-2304-0H3-B02
Work with a single 25 mm2 power cable to support a single XDM platform
only, with a maximum of 2250 W for that platform. This configuration
option is described in Connecting DC Input Power Cables to the xRAP-D
(page 4-49).
Work with a single 25 mm2 power cable to support two XDM platforms,
where each platform is limited to a maximum of 1100 W for per platform.
(Note that this configuration option is only available from V7.2, when the
management software enforces limitations on maximum power
consumption.) This configuration option requires the use of an optional
metal bridge component designed by ECI for this purpose.
Work with a single 50 mm2 power cable to support two XDM platforms,
with a maximum of 2250 W for each platform. This configuration option
requires the use of an optional metal bridge component designed by ECI
for this purpose.
4-53
2. Open the two captive screws fastening the xRAP-D front cover and remove
the cover.
Identify the various terminals located on the power source terminal board in
accordance with the following figure. This figure shows the terminals at the
source A side (main); the same board is used at the source B side
(protection).
Note that there are two complete sets of power terminals and circuit
breakers on each side. Separate input power cables from the user's input
power supply feed through the two sets of input power terminals into the
two circuit breakers on the source A side, supplying independent power
sources for up to two XDM shelves. Each circuit breaker feeds into a
separate power output connection for the power cable that connects to the
XDM platform.
4-54
417006-2304-0H3-B02
Similarly, separate input power cables from the user's input power supply
feed through separate input terminals into the two circuit breakers on the
source B side, and from the circuit breakers feed into the additional power
output connections that provide an optional protective backup power
supply for up to two XDM shelves.
The preceding figure portrays the electrical connections on the left side of
the xRAP-D, the side that connects to the user's main power supply for the
XDM shelves being powered. The right side of the xRAP-D contains a
mirror image of the connections illustrated in the preceding figure. The
right side connects to the user's (optional) backup protective power supply
for the shelves.
CAUTION: Before connecting the power leads, make sure to
3. Unscrew the washers that come already attached to the negative power
terminals.
4. Attach the metal bridge unit to the xRAP-D board by placing the openings
on the bridge unit over the screw posts of the negative power terminals of
the xRAP-D.
417006-2304-0H3-B02
4-55
5. Bring the two leads of one DC source input power cable to the appropriate
xRAP-D opening.
6. Attach the lug of the red lead to the positive input power stud terminals for
shelf 1, marked (+) on the power terminal board. Note that in this
configuration the xRAP-D works with one set of positive terminals, used
with one power cable. No cable is attached to the second set of positive
terminals.
7. Secure the lug using a flat washer, a spring washer, and a nut. Tighten the
nut with a torque of 450 N cm to 550 N cm.
8. Attach the lug of the black lead to the negative stud terminals on the back
of the bridge unit. Note that in this configuration the xRAP-D works with a
single set of negative terminals on the bridge unit, used with one power
cables.
9. Repeat Step 7 for the black lead lug.
10. If an additional backup power source (source B) is used, repeat Steps 3 to 9
for source B.
11. Route the DC input power cables towards the cable retainers at the rear of
the xRAP-D (see To ground the xRAP-D (page 4-48)), and attach them to
the retainers with cable ties.
4-56
417006-2304-0H3-B02
2. Find the replacement spacer screws included in the protective cover kit.
Note that four replacement spacer screws are included with the xRAP-D. A
replacement spacer screw is illustrated in the following figure.
417006-2304-0H3-B02
4-57
3. Replace the side screws with the replacement spacer screws. The following
figure illustrates the inside of the xRAP-D unit, highlighting the left side
replacement spacer screws in place.
4. Find the small L-shaped protective covers included in the kit. Four
protective covers are included for the xRAP-D. The protective covers are
illustrated in the following figure.
4-58
417006-2304-0H3-B02
5. Place the protective covers into the xRAP-D, two covers on each side. For
each protective cover, the smaller hole fits onto the top of the spacer screw
on one side and the two larger holes are anchored on top of the two
terminals above the spacer screw. The jutting-out edge of the protective
cover fits into the opening on the edge of the xRAP next to the terminals.
The following figure illustrates protective covers inserted into the xRAP-D
unit.
6. Secure the protective covers in place by screwing on the wing nuts supplied
in the kit onto the tops of the spacer screws on each side.
7. Find the protective bottom panel in the kit. The bottom panel for the
xRAP-D is illustrated in the following figure.
8. Secure the bottom panel into place with the four screws supplied in the kit.
417006-2304-0H3-B02
4-59
2. Insert the end of the DC power cable terminating with a 5-pin D-type male
connector near the SOURCE A power connectors and connect it to
connector Shelf 1 (see preceding figure).
3. Fasten the screws of the D-type connector.
4. If you are connecting an additional platform to the xRAP-D, repeat the
above steps for the second platform. Note that a maximum of 55A is
supplied from the power sources to each XDM platform. Power is supplied
independently to each XDM platform connected to the xRAP unit. Power is
not shared between XDM platforms.
5. If an additional power source is used, repeat the above steps to connect the
shelves to source B.
6. Route the DC power cables towards the cable retainers at the rear of the
xRAP-D and attach them to the retainers with cable ties (see To ground the
xRAP-D (page 4-48)).
7. Route each platform power cable along the rack side rails down to the
corresponding platform position, and securely attach the power cable to the
rack inner wall using cable ties. Attach a tag to each power connector in
accordance with its function.
NOTE: Connect the cables to the shelves only after
4-60
417006-2304-0H3-B02
417006-2304-0H3-B02
4-61
4-62
417006-2304-0H3-B02
417006-2304-0H3-B02
4-63
Attach the xRAP-B to the rack side rails in the top position, and secure it
with the four screws, washers, and nuts supplied in the installation parts kit.
4-64
417006-2304-0H3-B02
4. Connect the lug at the other end of the grounding lead to the rack
grounding stud.
2. Open the two captive screws fastening the xRAP-B front cover and remove
the cover.
417006-2304-0H3-B02
4-65
Identify the various terminals located on the power source terminal board in
accordance with the following figures. These figures show the terminals at
the source A side; the same board is used at the source B side.
3. Bring the two leads of one DC source input power cable to the appropriate
xRAP-B opening.
4. Attach the lug of the red lead to the positive stud terminals, marked (+) on
the power terminal board. Note that the xRAP-B works with a single set of
positive terminals, used with a 50 mm2 power cable.
5. Secure the lug using a flat washer, a spring washer, and a nut. Tighten the
nut with a torque of 450 N cm to 550 N cm.
6. Attach the lug of the black lead to the negative stud terminal marked (-) on
the power terminal board. Note that the xRAP-B works with a single set of
negative terminals, used with a 50 mm2 power cable.
7. Repeat Step 6 for the black lead lug.
8. If an additional power source (source B) is used, repeat Steps 3 to 8 for
source B.
9. Route the DC input power cables towards the cable retainers at the rear of
the xRAP-B (see the figure in To ground the xRAP-B (page 4-64)), and
attach them to the retainers with cable ties.
4-66
417006-2304-0H3-B02
2. Find the replacement spacer screws included in the protective cover kit.
Note that two replacement spacer screws are included with the xRAP-B. A
replacement spacer screw is illustrated in the following figure.
417006-2304-0H3-B02
4-67
3. Replace the side screws with the replacement spacer screws. The following
figure illustrates the inside of the xRAP-B unit, highlighting the left side
replacement spacer screw in place.
4. Find the small L-shaped protective covers included in the kit. Two
protective covers are included for use with the xRAP-B. The protective
covers are illustrated in the following figure.
4-68
417006-2304-0H3-B02
5. Place the protective covers into the xRAP-B, placing one cover on each
side. For each protective cover, the smaller hole fits onto the top of the
spacer screw on one side and the two larger holes are anchored on top of
the two terminals above the spacer screw. The jutting-out edge of the
protective cover fits into the opening on the edge of the xRAP next to the
terminals. The following figure illustrates a protective cover inserted into
the xRAP-B unit.
6. Secure the protective covers in place by screwing on the wing nuts supplied
in the kit onto the tops of the spacer screws on each side.
417006-2304-0H3-B02
4-69
7. Find the protective bottom panel in the kit. The bottom panel for the
xRAP-B is illustrated in the following figure.
8. Secure the bottom panel into place with the four screws supplied in the kit.
To connect the DC power cable for an XDM-500 platform:
1. Before starting, identify the platform power connectors on the xRAP-B
board in accordance with the following figures.
2. Insert the end of the DC power cable terminating with a 5-pin D-type male
connector near the SOURCE A power connectors and connect it to
connector Shelf 1 (see preceding figures).
3. Fasten the screws of the D-type connector.
4. If you are connecting an additional platform to the xRAP-B, repeat the
above steps for the second platform. Note that a maximum of 55A is
supplied from the power sources to each XDM platform. Power is supplied
independently to each XDM platform connected to the xRAP unit. Power is
not shared between XDM platforms.
5. If an additional power source is used, repeat the above steps to connect the
shelves to source B.
4-70
417006-2304-0H3-B02
6. Route the DC power cables towards the cable retainers at the rear of the
xRAP-B and attach them to the retainers with cable ties (see the figure in
To ground the xRAP-B (page 4-64)).
7. Route each platform power cable along the rack side rails down to the
corresponding platform position, and securely attach the power cable to the
rack inner wall using cable ties. Attach a tag to each power connector in
accordance with its function.
NOTE: Connect the cables to the shelves only after
4-71
4-72
417006-2304-0H3-B02
5. Route the alarm cables along the side of the rack down to the corresponding
platform position. Attach a tag to each connector in accordance with its
function.
6. If an additional platform is installed in the rack, repeat Steps 2, 3, 4, and 5
for the cables serving the additional platform. Make sure to attach
identification tags to each cable end.
417006-2304-0H3-B02
4-73
The slide switches, located on the rear side of the xRAP-HP, are used to route
the facility alarm lines to the alarm input and output lines of the XDM shelves
installed in the rack.
Before you start:
When the xRAP-HP is shipped, the switches are already set to meet the site
planning specifications. Use the following procedure to check the settings
before installing the xRAP-HP, and/or change the settings in accordance with
the current requirements.
4-74
417006-2304-0H3-B02
Setting switches 1&2 and 3&4 to position 1 connects the inputs and
outputs 1 through 4 in the CONTROL CONNECTION connector to
inputs and outputs 1 through 4 in the EXTERNAL
ALARM/CONTROL SHELF 1 connector.
Setting switch 5&6 to position 2 connects the inputs and outputs 5 and
6 in the CONTROL CONNECTION connector to the inputs and
outputs with the same numbers in the EXTERNAL
ALARM/CONTROL SHELF 2 connector.
Setting switch 7&8 to position 3 connects the inputs and outputs 7 and
8 in the CONTROL CONNECTION connector to the inputs and
outputs with the same numbers in the EXTERNAL
ALARM/CONTROL SHELF 3 connector.
2. Check the slide switch settings and verify that they meet the site planning
specifications.
3. If required, change the switch settings to the required position.
Table 4-8:
Slide switch
Switch
position
SHELF
connector
1&2
1, 2
SHELF 1
SHELF 2
SHELF 3
SHELF 1
SHELF 2
SHELF 3
SHELF 1
SHELF 2
SHELF 3
SHELF 1
SHELF 2
SHELF 3
3&4
5&6
7&8
417006-2304-0H3-B02
3, 4
5, 6
7, 8
4-75
The DC input power cables connect the two DC power sources and the
xRAP-HP source A and source B inputs. Two cables are required, one for each
source. Each cable consists of two stranded copper leads with a cross section of
50 mm2 (.078 in.2), one red and the other black. Each lead is terminated with a
two-hole compression lug from the installation parts kit supplied with the
equipment.
NOTE: When the xRAP-HP provides power to a single XDM
shelf, lower gauge cables may be used. Refer to DC Power
Cables (page 4-28) for DC power cable requirements.
CAUTION: If appropriate leads have already been prepared
4-76
417006-2304-0H3-B02
Attach the xRAP-HP to the side rails and secure it with the four screws,
washers, and nuts supplied in the installation parts kit.
417006-2304-0H3-B02
4-77
2. Open the two captive screws fastening the xRAP-HP front cover and
remove the cover.
3. Identify the various terminals located on the power source terminal board
by referring to the following figure (shows the terminals at the source A
side; the same board is used at the source B side).
4-78
417006-2304-0H3-B02
4. Bring the two leads of one DC source input power cable to the appropriate
xRAP-HP opening.
5. Attach the lug of the red lead to the positive stud terminal marked (+) on
the power terminal board (see the previous figure).
6. Secure the lug using a flat washer, a spring washer, and a nut. Tighten the
nut with a torque of 1150 N cm to 1300 N cm.
7. Attach the lug of the black lead to the negative stud terminal marked (-) on
the power terminal board (see the previous figure).
8. Repeat Step 5 for the black lead lug.
9. If an additional power source (source B) is used, repeat Steps 3 to 8 for
source B.
10. Route the DC input power cables towards the cable retainers at the rear of
the xRAP-HP (see figure in To Ground the xRAP-HP (page 4-77)), and
attach them to the retainers with cable ties.
11. Securely attach the DC input power cables to the rack inner wall using
cable ties.
During the following procedure, refer to the figures illustrating the connectors
in To connect DC input power cables to the xRAP-HP (page 4-78).
To connect the DC power cable for a platform:
1. Before starting, identify the openings used to route power cables to the
xRAP-HP.
2. Insert the DC power cable end terminated in lugs of one XDM platform
through the source A xRAP-HP opening. If two shelves are installed in the
rack, start by connecting the shelf 1 cable.
3. Attach the red lead lug of the platform power cable to the positive stud
terminal of shelf 1 on the power terminal board.
4. Secure the lug using a flat washer, a spring washer, and a nut. Tighten the
nut with a torque of 800 N cm to 870 N cm.
5. Attach the black lead lug of the power cable to the negative stud terminal of
shelf 1 on the power terminal board.
6. Repeat Step 3 for the black lead lug.
7. Attach the grounding (shield) lead lug of the platform power cable to the
ground stud terminal located on the xRAP-HP side panel.
8. Repeat Step 3 for the grounding lead lug.
9. If a second XDM platform is installed in the rack, repeat Steps 2 to 7 for
the shelf 2 power cable.
417006-2304-0H3-B02
4-79
4-80
417006-2304-0H3-B02
5. Make sure the voltage is within the allowed range (-40 VDC to -72 VDC),
and that it has the correct polarity.
6. Return all the xRAP-HP circuit breakers to OFF.
7. Disconnect the xRAP-HP input power sources.
8. Reinstall the xRAP-HP front cover and fasten it using the two captive
screws.
To connect the alarm cables to the xRAP-HP:
1. Before starting, make sure you have all the necessary cables.
2. Refer to the figure in To connect DC input power cables to the xRAP-HP
(page 4-78) to identify the xRAP-HP connector functions.
3. Connect the 50-pin D-type connector of the facility alarm monitoring cable
to the xRAP-HP CONTROL CONNECTION connector, and then securely
attach the cable to the rack inner wall using cable ties.
4. Connect the 25-pin connector of the alarm monitoring cable for shelf 1 to
the xRAP-HP EXTERNAL ALARM/CONTROL SHELF 1 connector.
5. Connect the 9-pin D-type connector of the alarms indications cable for
shelf 1 to the xRAP-HP RAP SHELF 1 connector.
417006-2304-0H3-B02
4-81
6. Route the two cables along the side of the rack down to the corresponding
shelf position. Attach a tag to each connector in accordance with its
function.
7. If you are installing additional shelves in the rack, repeat Steps 2, 3, 4, and
5 for the cables serving them. Make sure to attach identification tags to
each cable end.
4-82
417006-2304-0H3-B02
The DC input power cables connect between the two DC power sources and
the xRAP-100 source A and source B inputs. Two cables are required, one for
each source.
Each cable consists of two stranded copper leads with a cross section of
35 mm2 (.055 in.2), one red and the other black. Each lead is terminated with a
two-hole compression lug from the installation parts kit supplied with the
equipment.
CAUTION: If appropriate leads have already been prepared
Attach the xRAP-100 to the rack side rails in the top position and secure it
with the four screws, washers, and nuts supplied in the installation parts kit.
417006-2304-0H3-B02
4-83
4-84
417006-2304-0H3-B02
417006-2304-0H3-B02
4-85
2. Identify the various terminals located on the power source terminal boards
in accordance with the following figure. This figure shows the terminals at
the source A side; the same board is used at the source B side.
3. Bring the two leads of one DC source input power cable to the appropriate
xRAP-100 opening.
4. Attach the lug of the red lead to the positive stud terminal marked (+) on
the power terminal board.
5. Secure the lug using a flat washer, a spring washer, and a nut. Tighten the
nut with a torque of 450 N cm to 550 N cm.
6. Attach the lug of the black lead to the negative stud terminal marked (-) on
the power terminals board.
7. Repeat Step 5 for the black lead lug.
8. If an additional power source (source B) is used, repeat Steps 3 to 7 above
for source B.
9. Route the DC input power cables towards the cable retainers at the rear of
the xRAP-100, and attach them to the bracket with cable ties.
10. Securely attach the DC input power cables to the rack inner wall using
cable ties.
4-86
417006-2304-0H3-B02
417006-2304-0H3-B02
4-87
4. If an additional power source is used, repeat the above steps to connect the
shelves to source B.
5. Route the DC power cables towards the cable retainers at the rear of the
xRAP-100, and attach them to the retainers with cable ties.
6. Route each platform power cable along the rack side rails down to the
corresponding platform position, then securely attach the power cable to the
rack inner wall using cable ties. Attach a tag to each power connector in
accordance with its function.
NOTE: Connect the cables to the shelves only after
4-88
417006-2304-0H3-B02
417006-2304-0H3-B02
4-89
4-90
417006-2304-0H3-B02
Each cable consists of two stranded copper leads with a cross section of
35 mm2 (.055 in.2), one red and the other black. Each lead terminates with a
two-hole compression lug from the installation parts kit supplied with the
equipment.
CAUTION: If appropriate leads have already been prepared
at the prescribed rack location, make sure that the leads are
not connected to any live voltage source before attaching the
lugs. If appropriate leads have already been prepared at the
prescribed rack location, make sure that the leads are not
connected to any live voltage source before attaching the lugs.
Attach the miniRAP to the rack side rails in the top position of the rack,
and secure it with the four screws, washers, and nuts supplied in the
installation parts kit.
417006-2304-0H3-B02
4-91
4-92
417006-2304-0H3-B02
3. Bring the two leads of one DC source input power cable to the appropriate
miniRAP opening.
4. Attach the lug of the red lead to the positive stud terminal marked (+) on
the power terminal board (see the previous figure).
5. Secure the lug using a flat washer, a spring washer, and a nut. Tighten the
nut with a torque of 450 N cm to 550 N cm.
6. Attach the lug of the black lead to the negative stud terminal marked (-) on
the power terminal board (see the previous figure).
7. Repeat Step 5 for the black lead lug.
8. If you are using an additional power source (source B), repeat Steps 2 to 7
for source B.
9. Route the DC input power cables towards the cable supports at the rear of
the miniRAP (see Location of miniRAP grounding stud (page 4-92)), and
attach them to the supports with cable ties.
417006-2304-0H3-B02
4-93
4-94
417006-2304-0H3-B02
417006-2304-0H3-B02
4-95
4-96
417006-2304-0H3-B02
6. Thread the fibers into the FST, as illustrated in the following figure.
417006-2304-0H3-B02
4-97
4-98
417006-2304-0H3-B02
2. Hold the end of the swing-out tray and pull it out to gain access to the ODF
components.
3. Open the two cover thumb nuts and remove the protective cover from the
ODF splice support.
417006-2304-0H3-B02
4-99
5. Route the fiber ends through the cable guides to the splice support area.
6. Identify the adapter panel pigtail to be spliced to each user fiber.
7. Insert splicing sleeves over the pigtail, splice the user fiber to the pigtail,
and slide the splicing sleeve over the splice.
8. Place the splicing sleeve in one of the slots in the splice support.
NOTE: When more than 12 fibers are connected to the ODF,
first start filling the slots of the lower splice support. After the
slots are occupied, reinstall the top splice support and
continue filling the support slots.
9. After splicing all the fibers, reinstall the protective cover removed in Step
3.
10. Push the swing-out tray back into the unit.
11. Close the ODF front cover by pushing it up till it clicks to the unit.
12. Refer to Attaching rack mount brackets (page 4-98) and secure the user
fibers with cable ties to the fiber-fastening bracket at the rear of the ODF.
CAUTION: To prevent damage to fibers, do not tighten the
cable ties.
4-100
417006-2304-0H3-B02
Install each ODF in the prescribed rack position and fasten it to the rack
side rails with four screws.
417006-2304-0H3-B02
4-101
4-102
417006-2304-0H3-B02
5
XDM-500 Platform
Installation
In this chapter:
Overview ......................................................................................................... 5-1
Assembling the XDM Platform in a Rack ....................................................... 5-2
Installing Air Filters......................................................................................... 5-6
Connecting Power and Rack Alarm Cables to the Platforms ........................ 5-10
Overview
This section provides installation instructions for the XDM-200, XDM-500,
XDM-1000, and XDM-2000 platforms. As a standard, XDM platforms are
supplied with the INF, FCU, and ECB already installed. Therefore, the
installation activities covered in this section include:
1. Assembling an XDM platform in a rack.
2. Grounding.
3. Installing air filters in the platform.
4. Installing xMCP and MECP cards in the XDM platform.
5. Connecting power and rack alarm cables to the platform.
6. Installing heat buffers and cable guides (when relevant).
Once you have performed these activities, the XDM platform is ready for the
installation of the prescribed cards and modules. The platform front door will
be installed only after completing the installation of cards and modules, and
after connecting cables to the cards cage.
417006-2304-0H3-B02
5-1
not connected to the rack, and that the circuit breakers in the
xRAP or in the user-provided power distribution panel are set
to OFF.
inspect the pins of the backplane connectors for bent pins and
any other signs of physical damage. Do not install the
platform if connector pins are bent or touching, as this may
cause severe damage to the backplane.
2. Locate the cage nut holes in the rack frame. The cage nut holes appear at
intervals running up and down the front of the two sides of the rack frame.
Cage nut holes are used to hold the cage nuts with which the different
accessories are attached to the rack frame.
3. Insert cage nuts into the holes located at intervals along the length of the
rack frame, on both sides of the rack. Install cage nuts in the holes at the
correct height for the equipment being installed in the rack, based on your
specific equipment installation plan.
5-2
417006-2304-0H3-B02
4. Obtain help from an additional person to place the XDM platform in its
prescribed position, and then insert the platform guide posts in the
matching holes in the rack side rails. This will help keep the platform in
position until fastened to the rack with the screws.
5. Have the other person hold the XDM platform in place, and fasten the
platform to the rack side rails with four M6 screws, washers, and nuts.
6. Repeat Steps 1 and 2 above for each platform to be installed in the rack
(when relevant).
417006-2304-0H3-B02
5-3
5-4
417006-2304-0H3-B02
7. Connect the lug at the free end of the grounding cable to the grounding
studs on the platform. Note that the lug at the end of the grounding cable
must be inserted over both grounding studs.
8. Secure each lug connection using the flat washer, serrated lock washer, and
nut. Tighten the nuts with a torque of 450 N cm to 550 N cm.
417006-2304-0H3-B02
5-5
High-density foam filter (45 PPI), for extremely dusty sites and when
NEBS compliance is required
NOTE: It is not recommended to use air filters in
The air filter is attached under the platform below the xFCU units, using a
dedicated installation kit.
5-6
417006-2304-0H3-B02
The following figure shows a general view of the air filter and its installation
kit. This kit includes a frame with a removable front panel and the hardware
(seven spacers) needed for its installation under the platform.
417006-2304-0H3-B02
5-7
5-8
417006-2304-0H3-B02
4. Reinstall the filter front panel and fasten it to the frame with its two captive
screws.
CAUTION: Install only a filter of the original type. Failure to
do so can impair equipment reliability and performance.
417006-2304-0H3-B02
5-9
5-10
417006-2304-0H3-B02
Connect the power and bay alarm cables from the xRAP to the xINF and
xFCU units of each XDM platform. The xRAP-D installation procedure is
described in Installing the xRAP-D (page 4-45), the xRAP-B installation
procedure is described in Installing the xRAP-B (page 4-63), the xRAP-HP
installation procedure is described in Installing the xRAP-HP (page 4-73),
and the xRAP-100 installation procedure is described in Installing the
xRAP-100 (page 4-82).
As part of the xRAP installation procedure, cables are routed from the
appropriate xRAP connectors, as specified in the rack installation plan,
toward each XDM platform installed in the rack. At this stage, connect the
free ends of these cables, in accordance with the rack installation plan and
the cable tags, to the appropriate XDM platform connectors.
NOTE: At this stage, you may also install accessories such as
heat buffers and cable guides which sit above the XDM
platforms.
417006-2304-0H3-B02
5-11
The complete list of cables connecting between the XDM platforms and the
xRAP unit is shown in Connecting power and bay alarm cables.
xRAP connector
xINF 1 POWER IN
Connection of DC power
from source A to the
XDM platform.
xINF 2 POWER IN
Connection of DC power
from source B to the
XDM platform.
ALARMS
Connection of platform
alarm inputs and outputs.
EXTERNAL
ALARM/CONTROL PLATFORM 1
RAP
Connection of platform
alarm indications (relays
and buzzer).
RAP - SHELF 1
xINF 1 POWER IN
Connection of DC power
from source A to the
XDM platform.
xINF 2 POWER IN
Connection of DC power
from source B to the
XDM platform.
ALARMS
Connection of platform
alarm inputs and outputs.
EXTERNAL
ALARM/CONTROL SHELF 2
RAP
Connection of platform
alarm indications (relays
and buzzer).
RAP- SHELF 2
Connector
5-12
Cable function
Platform
417006-2304-0H3-B02
417006-2304-0H3-B02
5-13
5-14
417006-2304-0H3-B02
6
Card and Module Installation
In this chapter:
Overview ......................................................................................................... 6-1
Card Installation Precautions ........................................................................... 6-3
XDM-500 Slot Utilization ............................................................................... 6-4
Installation Data for XDM-500 I/O Cards and Associated Modules............... 6-6
Using Electrical Interface Protection Modules ................................................ 6-9
Preparing Cards and Modules for Installation ............................................... 6-10
Installing CMBR40 and TRP40_2 Cards for Different Configuration Options6-6
Installing xMCP Cards .................................................................................. 6-73
Installing xMCP-B/B2G Cards ...................................................................... 6-75
Installing MECP Cards .................................................................................. 6-78
Installing Aurora-G Cards ............................................................................. 6-79
Installing I/O Cards and Modules .................................................................. 6-90
Installing a Card in the CCP Cage ................................................................. 6-92
Overview
This chapter describes how to insert cards into XDM platform slots.
Card insertion is essentially not complicated. Take the card, make sure that all
pins and connectors are straight, and gently insert the card into the appropriate
slot. It should slide in easily. The same standard installation instructions
generally apply to all cards of the same type.
417006-2304-0H3-B02
6-1
Identify the slot into which you wish to insert the I/O card. Specific
information about slot capacities and limitations are provided in XDM-500
Slot Utilization (page 6-4).
Prepare the electrical interface protection modules (if any) that you plan to
use, as described in Using Electrical Interface Protection Modules.
XDM I/O cards often work with a variety of slide-in or plug-in modules
and components. Most of these modules and components can be inserted
and replaced while the system is running (hot insertion). However, when
initially installing and starting a system, you should first prepare the I/O
cards by inserting the modules and components, and only afterwards insert
the cards into the appropriate slots. This simplifies the initial system setup
and configuration. Instructions for sliding these modules and components
into the relevant I/O cards are provided in Preparing Cards and Modules for
Installation (page 6-10). The CMBR40 and TRP40_2 cards can require
special installation steps when installed for certain configurations. These
steps are provided in Installing CMBR40 and TRP40_2 Cards for Different
Configuration Options (page 6-69)
Insert any xMCP or xMCP-B cards included with your system into the
selected C1 and/or C2 slots, as described in Installing xMCP Cards (page
6-73) and Installing MECP Cards (page 6-78).
Insert any Aurora cards included with your system into the selected I/O
card slots and configure the cards for use, as described in Installing AuroraG Cards (page 6-79).
Insert any I/O cards included with your system into the selected I/O card
slots, as described in Installing I/O Cards and Modules (page 6-90).
Insert any CCP cards included with your system into the selected modules
cage slots, as described in Installing a Card in the CCP Cage (page 6-92).
Before you begin to install cards, be sure to read the precautions in Card
Installation Precautions (page 6-3).
6-2
417006-2304-0H3-B02
CAUTION:
417006-2304-0H3-B02
6-3
Most optical I/O slot cards can be installed in any I/O slot. Some optical cards
are double I/O slot cards that can only be installed in specific pairs of slots. For
more information about slot requirements for optical cards, see each card's
description in the XDM-1000 Product Line Reference Manual.
NOTE: If you are installing two TRP40_2 or CMBR40 cards as
an OCH 1 + 1 protection pair, see Installing Two TRP40_2 or
CMBR40 Cards as an OCH 1+1 Protection Pair (page 6-71) for
slot information and other installation instructions.
If you are installing two TRP40_2 cards in regenerator mode, see
Installing TRP40_2 Cards for Regenerator Mode (page 6-69) for
slot information and other installation instructions.
6-4
417006-2304-0H3-B02
Common cards, such as HLXC and XIO cards, affect the capacity of each I/O
slot. The following table provides installation data for certain XDM-500 I/O
cards and associated modules. Use this data to determine which slots you can
use for each type of card. For more information about DWDM modules, see the
XDM Reference Manual and the XDM System Specifications.
NOTE: When an XIO card is installed in the shelf, the table
lists the slots that enable PIO and SIO cards to use their full
service bandwidth. However, PIO and SIO cards may also be
installed in slots with a lower service bandwidth, provided the
bandwidth configured for the card does not exceed the slot
service bandwidth.
417006-2304-0H3-B02
6-5
Service type
Card
Electrical interface
module type
SDH
IC1 to IC6
IC1 to IC6
IC1 to IC6
Not applicable
M1_16BT, M1_16DI
M1_16P
M1_8BT, M1_8DI
None
13
SIO1&4B optical
IC1 to IC6
IC2 to IC5
With xMCP-B:
IC1 to IC6
With xMCP:
IC3 and IC4 only
Not applicable
IC2, IC5
With xMCP-B:
IC1, IC2, IC5, IC6
With xMCP:
not available
M1_16SFP
Not applicable
SIO16, SIO16M
IC1 to IC6
IC2 to IC5
IC1 to IC6
Not applicable
SIO16_2B
IC1 to IC6
IC2 to IC5
IC1 to IC6
Not applicable
SIO16_4B
Not applicable
Not applicable
Not applicable
10
XIO192 supports two configurations; one STM-16 with one STM-4 interface, or one STM-16 with four STM-1 interfaces.
XIO384F supports one STM-64/OTU2 or four STM-16/OTU1 ports in each slot.
PIO345 and SIO1&4 (DS-3 and E3 electrical interfaces) can only be installed in slots IC2 or IC5.
13
SIO1&4B requires use of xMCP-B or regular xMCP with minimum of 256 MB RAM memory. A Regular xMCP with only 128 MB RAM cannot support the SIO1&4B.
11
12
6-6
417006-2304-0H3-B02
Service type
Card
Electrical interface
module type
IC2+IC3 or IC4+IC5
(double-slot card)
IC2+IC3 and/or
IC4+IC5 (double-slot
card)
IC2+IC3 and/or
IC4+IC5 (double-slot
card)
Not applicable
Not applicable
SIO64B
PDH
SIO164
Not applicable
Not applicable
IC3+IC4 (double-slot
card)
Not applicable
PIO2_21
M2_21B, M2_21U,
M2_84
M2_84P
M2_84P
Not applicable
M2_84B, M2_84U
M2_84P
M2_84BR, M2_84UR
Not applicable
PIO2_84
PIO345_16, PIO345M_16
Data/MPLS
14
DIO1_40
IC1 to IC6
IC2 to IC5
Not applicable
Not applicable
DIO1_61
IC1 to IC6
IC1 to IC6
Not applicable
Not applicable
DIO1_80
IC1 to IC6
IC2 to IC5
Not applicable
Not applicable
IC2 to IC5
IC1 to IC6
Not applicable
IC2, IC5
ME_8, ME_14 14
Not applicable
IC1 to IC6
IC2 to IC5
IC1 to IC6
Not applicable
IC2, IC5
ME_8, ME_14
Not applicable
417006-2304-0H3-B02
6-7
Card
Electrical interface
module type
IC1 to IC6
IC2 to IC5
IC1 to IC6
Not applicable
IC2, IC5
ME16
Not applicable
IC1 to IC6
IC2 to IC5
IC1 to IC6
Not applicable
IC2, IC5
ME16
Not applicable
IC1 to IC6
IC2 to IC5
IC1 to IC6
Not applicable
IC2, IC5
ME16
Not applicable
Not applicable
Not applicable
IC3, IC4
Not applicable
Not applicable
Not applicable
IC3, IC4
Not applicable
ASON
ACP1000
MC1 to MC4
MC1 to MC4
MC1 to MC4
Not applicable
Not applicable
Encryption
Aurora-G
IC1 to IC6
IC1 to IC6
IC1 to IC6
Not applicable
Not applicable
ATM
ATS
IC1 to IC6
IC1 to IC6
IC1 to IC6
Not applicable
Service type
15
6-8
417006-2304-0H3-B02
Protection for E1 I/O cards. The protection module for this type of I/O
interface, designated M2_84P, can serve both balanced and unbalanced
interfaces. The M2_84P module can be installed in any one of the M1 to
M6 slots, and the associated PIO2_84 card protects all the other PIO2_84
cards. For an XDM-500 fully equipped with PIO2_84 cards, the resulting
protection ratio is 1:4; higher protection ratios are achieved when the
number of PIO2_84 cards installed in the shelf is lower than 4.
Protection for E3/DS-3/STS-1 I/O cards. The protection module for this
type of interface is designated M345_16P. The M345_16P module can be
installed in slots M1 or M2 or M5 or M6; in this case, the PIO345_16 card
installed in slot I1, I2, I5 or I6 protects all the other PIO345_16 cards.
For an XDM-500 fully equipped with PIO345_16 cards, the resulting
protection ratio is 1:4; higher protection ratios are achieved when the
number of PIO345_16 cards installed in the shelf is less than 4.
Protection for STM-1 electrical I/O cards. The protection module for this
type of interface is designated M1_16P. The M1_16P module can be
installed in slots M1 or M2 or M5 or M6; in this case, the SIO1_16e card
installed in slot I1, I2, I5 or I6 protects all the other SIO1_16e cards.
NOTE: In the XDM-500 there is no option to protect a
PIO345 card and a SIO1&4 card on the same shelf. Unlike
the XDM-1000, the XDM-500 has only one high order
protection for STM-1 or DS-3/E3 interfaces.
417006-2304-0H3-B02
6-9
6-10
417006-2304-0H3-B02
417006-2304-0H3-B02
6-11
6-12
417006-2304-0H3-B02
417006-2304-0H3-B02
6-13
2. Insert the rear end of the module into the card guides, and push slowly
backward to mate the connectors. Make sure the fastening screw is free to
move backward as the module slides in. If resistance is felt before the
connectors are fully mated, retract the module and repeat the insertion.
3. Fasten the module with its captive screw.
6-14
417006-2304-0H3-B02
417006-2304-0H3-B02
6-15
6-16
417006-2304-0H3-B02
SIO16 cards can be equipped with one or two extractable optical modules. Live
insertion and hot swapping of modules is allowed.
CAUTION: Do not install an OM16 optical transceiver
417006-2304-0H3-B02
6-17
2. Insert the rear end of the transceiver into the card guides, and push slowly
backward to mate the connectors. If resistance is felt before the connectors
are fully mated, retract the transceiver and repeat the insertion.
3. Fasten the transceiver with its captive screw.
6-18
417006-2304-0H3-B02
417006-2304-0H3-B02
6-19
6-20
417006-2304-0H3-B02
6. Insert the rear end of the replacement optical module into the card guides
and push slowly backward to mate the connectors. Make sure the fastening
screw is free to move backward as the optical module slides in. If you feel
resistance before the connectors are fully mated, retract the optical module
and repeat the insertion.
7. Fasten the optical module with its captive screw.
NOTE: A special SFP locker may be installed on the
417006-2304-0H3-B02
6-21
6-22
417006-2304-0H3-B02
417006-2304-0H3-B02
6-23
The following figure shows how to install the extractable module (the figure
uses the OMTX10_S for illustration).
6-24
417006-2304-0H3-B02
417006-2304-0H3-B02
6-25
2. Insert the rear end of the module into the card guides and push slowly
backward to mate the connectors. If resistance is felt before the connectors
are fully mated, retract the transceiver and repeat the insertion.
3. Fasten the transceiver with its captive screw.
6-26
417006-2304-0H3-B02
417006-2304-0H3-B02
6-27
The following figure shows how to install an extractable module (the figure
uses the OMTX10_EF for illustration).
6-28
417006-2304-0H3-B02
417006-2304-0H3-B02
6-29
6-30
417006-2304-0H3-B02
417006-2304-0H3-B02
6-31
417006-2304-0H3-B02
417006-2304-0H3-B02
6-33
All the EIS card versions have eight positions for the installation of optical
transceiver plug-ins (SFPs). The following figure identifies these positions.
The optical transceiver plug-ins can be installed in the various positions:
The optical transceiver plug-ins can be installed and replaced in the field as
required.
Do not install optical transceiver plug-ins for ports that are served by electrical
interfaces located in the ME_8 module.
6-34
417006-2304-0H3-B02
417006-2304-0H3-B02
6-35
For DIO1_40: GbE optical interface modules in the two upper positions,
each equipped with two optical transceiver plug-ins (SFPs).
For DIO1_80: GbE optical interface modules in all of the four positions,
each equipped with two optical transceiver plug-ins (SFPs).
The optical transceiver plug-in can be installed and replaced in the field as
required. You cannot replace the optical interface modules.
6-36
417006-2304-0H3-B02
417006-2304-0H3-B02
6-37
The DIOB card has eight positions for the installation of optical transceiver
plug-ins (SFPs). The following figure identifies these positions.
The optical transceiver plug-ins can be installed and replaced in the field as
required.
To install an optical transceiver plug-in module in DIOB
cards:
1. Identify the prescribed installation position of the optical transceiver
plug-in (see the following figure).
2. To install or replace a transceiver, refer to Installing and removing optical
transceivers (page 6-11).
NOTE: If you replace a transceiver on a card installed in a
working platform, first turn the reset control to the reset (up)
position. After inserting the SFP, you can return the reset
control to the normal (horizontal) position.
6-38
417006-2304-0H3-B02
417006-2304-0H3-B02
6-39
The MCS5/MCS10 card has eight positions for the installation of optical
transceiver plug-ins (SFPs). The optical transceiver plug-ins can be installed
and replaced in the field as required.
6-40
417006-2304-0H3-B02
working platform, first turn the reset control to the reset (up)
position. After inserting the SFP, you can return the reset
control to the normal (horizontal) position.
417006-2304-0H3-B02
6-41
6-42
417006-2304-0H3-B02
working platform, first turn the reset control to the reset (up)
position. After inserting the XFP, you can return the reset
control to the normal (horizontal) position.
417006-2304-0H3-B02
6-43
6-44
417006-2304-0H3-B02
417006-2304-0H3-B02
6-45
6-46
417006-2304-0H3-B02
417006-2304-0H3-B02
6-47
6-48
417006-2304-0H3-B02
417006-2304-0H3-B02
6-49
6-50
417006-2304-0H3-B02
417006-2304-0H3-B02
6-51
6-52
417006-2304-0H3-B02
417006-2304-0H3-B02
6-53
6-54
417006-2304-0H3-B02
417006-2304-0H3-B02
6-55
6-56
417006-2304-0H3-B02
417006-2304-0H3-B02
6-57
Figure 6-31: Identifying the optical transceiver plug-in (XFP) position in the
TRP10_LAN card
6-58
417006-2304-0H3-B02
417006-2304-0H3-B02
6-59
4. Insert the rear end of the extractable optical module into the guides of the
module installation position, and push slowly backwards to mate the
connectors. If resistance is felt before the connectors are fully mated, retract
the module and repeat the insertion.
5. Press the two extractors to lock the extractable optical module in place.
When the module is properly inserted, the extractors are vertical and touch
the module edge.
6. Secure the extractable optical module extractors with the two screws.
7. If necessary, repeat the procedure for the second extractable optical
module.
To install the optical transceiver plug-in (SFP) module:
6-60
417006-2304-0H3-B02
417006-2304-0H3-B02
6-61
4. Insert the rear end of the extractable optical module into the guides of the
module installation position, and push slowly backwards to mate the
connectors. If resistance is felt before the connectors are fully mated, retract
the module and repeat the insertion.
5. Press the two extractors to lock the extractable optical module in place.
When the module is properly inserted, the extractors are vertical and touch
the module edge.
6. Secure the extractable optical module extractors with the two screws.
6-62
417006-2304-0H3-B02
417006-2304-0H3-B02
6-63
By following the following instructions, you can install the desired plug-in
modules according to the required functionality.
6-64
417006-2304-0H3-B02
417006-2304-0H3-B02
6-65
3. Inspect the rear optical connector of the plug-in module, and clean foreign
matter and dust using an approved cleaning compound.
4. Insert the rear end of the plug-in module into the card guides, and push
slowly backward to mate the connector.
Make sure the fastening screws are free to move backward as the module
slides in. If resistance is felt before the connectors are fully mated, retract
the module and repeat the insertion.
5. Fasten the plug-in module with its two captive screws.
6-66
417006-2304-0H3-B02
417006-2304-0H3-B02
6-67
6-68
417006-2304-0H3-B02
417006-2304-0H3-B02
6-69
3. Connect an optical fiber from the client port of one of the cards to the client
port of the other card. The following figure shows the position of the client
port on each card:
The two TRP40_2 cards are now installed correctly for configuration in
regenerator mode.
6-70
417006-2304-0H3-B02
417006-2304-0H3-B02
6-71
The following figure shows the position of the IOP cable port on the
CMBR40 card.
6-72
417006-2304-0H3-B02
align the card with the platform guide rails. If resistance is felt
during insertion, immediately retract the card/module and
repeat the process.
Hold the card straight during insertion and removal, and pull
or push it slowly and carefully to avoid touching components
located on adjacent cards.
Do not use excessive torque when tightening fastening
screws.
417006-2304-0H3-B02
6-73
6-74
417006-2304-0H3-B02
align the card with the platform guide rails. If resistance is felt
during insertion, immediately retract the card/module and
repeat the process.
Hold the card straight during insertion and removal, and pull
or push it slowly and carefully to avoid touching components
located on adjacent cards.
Do not use excessive torque when tightening fastening
screws.
417006-2304-0H3-B02
6-75
6-76
417006-2304-0H3-B02
d. Place the NVM cover on the NVM and close it with its two captive
screws, as illustrated.
NOTE: If the NVM cover is not closed properly the system
will not operate.
417006-2304-0H3-B02
6-77
align the card with the platform guide rails. If resistance is felt
during insertion, immediately retract the card/module and
then repeat the process.
Hold the card straight during insertion and removal, and pull
or push it slowly and carefully to avoid touching components
located on adjacent cards.
Do not use excessive torque when tightening fastening
screws.
6-78
417006-2304-0H3-B02
417006-2304-0H3-B02
6-79
Aurora-G cables
Aurora-G port
SFP
Cable
Mating
connector
Quantity
per card
RS-232 local PC
port
---
DB-9 male
Gigabit Ethernet
local and remote
ports
RJ-45 male
---
RJ-45 male
10/100 Ethernet
Management ports
2
(1 per port)
16
The 10/100 Management port is autosensing for polarity. You can use either a crossover cable or a shielded
Category 5 straight through cable when connecting to this port.
6-80
417006-2304-0H3-B02
Aurora-G cards can be installed in any I/O slot of the XDM-500 cage. The
procedures in this section can also be used to replace cards in an operating
platform, provided the safety precautions are strictly obeyed. Refer to the
safety guidelines provided in Before You Start/Safety Guidelines (page
1-1).
417006-2304-0H3-B02
6-81
6-82
417006-2304-0H3-B02
417006-2304-0H3-B02
6-83
6-84
417006-2304-0H3-B02
417006-2304-0H3-B02
6-85
6-86
Parameter
Value
Baud speed
115,200
Parity
None
Data bits
Stop bits
Flow control
None
417006-2304-0H3-B02
4. At the Username: prompt, type the user name admin and press
ENTER. The CLI Password: prompt appears.
User Access Verification
Username: admin
Password:
5. At the Password: prompt, type the default password admin and press
ENTER.
When you have successfully logged in, the admin> prompt appears as
follows.
User Access Verification
Username: admin
Password:
admin>
417006-2304-0H3-B02
6-87
The default gateway identifies the local router port on the same subnet as
the Aurora-G 10/100 management port. The Aurora-G sends all packets to
the specified router for forwarding to the management station. The
following figure illustrates a default gateway when the Network
Management Host and Aurora-G are on different subnets. The Network
Management Hosts IP address is 192.168.1.10, and the management port
IP address is 192.168.10.10. To send packets between the two devices, the
local port on Router #1 is specified as the default gateway (192.168.10.1).
The gateway address must match the subnet of the management port.
Replace the command line parameters in the preceding command line with
the appropriate values, as explained in the following table.
6-88
417006-2304-0H3-B02
Table 6-5:
Parameter
Description
<ip address>
<subnet mask>
<gateway>
417006-2304-0H3-B02
6-89
6-90
417006-2304-0H3-B02
5. The cards have either one or two extractors. Move all extractor handles to
the horizontal position before inserting the card in its slot.
6. Identify the assigned slot and insert the rear end of the card in the
corresponding card guides.
7. Push the card in until it mates the chassis connectors. If resistance is felt
before the connectors are mated, pull the card out and repeat the procedure.
417006-2304-0H3-B02
6-91
8. For cards with reset control, for example HLXC, SIO164, Aurora-G, and so
on, return the reset control to the horizontal position to release the extractor
handle.
9. Press the ends of all extractor handles to fully insert the card and lock it in
place.
10. After inserting all the cards, check the card insertion diagram that
everything is correct.
6-92
417006-2304-0H3-B02
417006-2304-0H3-B02
6-93
6-94
417006-2304-0H3-B02
7
Optical Fiber and Cable
Installation and Routing
In this chapter:
Connecting Cables ........................................................................................... 7-1
Connecting Cables
This section provides instructions for connecting cables to XDM platforms.
The information presented in this section supplements the information
regarding the connection of power, alarm, traffic, and grounding cables given
in Installing Ancillary Units in Racks (page 4-44).
Connect the cables to the equipment connectors according to the information
appearing in the relevant cabling diagrams or tables. To identify the physical
location of connectors, use the equipment panel figures appearing in this
section and in the XDM-1000 Product Line Reference Manual.
417006-2304-0H3-B02
7-1
7-2
417006-2304-0H3-B02
417006-2304-0H3-B02
7-3
4. At the desired exit point, route the fibers through one of the conduit slots.
The following figure shows details of cable and fiber routing within the
rack:
Cables are pulled through the cable conduit down to the level of the
connectors to which they will be connected.
Fibers are taken from the nearest FST and routed through the side fiber
conduit. To open the conduit, temporarily remove the relevant sections
of its cover.
7-4
417006-2304-0H3-B02
417006-2304-0H3-B02
7-5
All external optical fibers are terminated on FSTs. The fibers are then routed
through the fiber guides that run along the rack sides down to the level of the
equipment to which they are connected.
CAUTION: Make sure that all the optical connectors are
7-6
417006-2304-0H3-B02
417006-2304-0H3-B02
7-7
7-8
417006-2304-0H3-B02
417006-2304-0H3-B02
7-9
Place warning labels alongside all the connectors of fibers that carry
OFA_R/RM/HRM signals, in particular on the ODF connectors, as follows:
HAZARD LEVEL 3B.
DO NOT DISCONNECT UNDER OPERATION.
7-10
417006-2304-0H3-B02
Connection instructions
Before you start:
1. Use a microscope to check that the LINE connector and the mating fiber
connector are clean.
2. Familiarize yourself with the items identified in the following figures.
3. Read the OFA_R/RM/HRM specific safety instructions.
To connect fibers to the SVC and EDFA connectors:
1. Bring the end of the fiber intended for connection near the SVC connector.
2. Remove the SVC connector cap and immediately connect the fiber to the
connector.
3. Route the fiber intended for connection to the EDFA connector along the
right-hand side of the card, through the upper fiber guide, and bring its end
near the connector.
4. Remove the EDFA connector cap and immediately connect the fiber to the
connector.
417006-2304-0H3-B02
7-11
7-12
417006-2304-0H3-B02
417006-2304-0H3-B02
7-13
These instructions will help you prevent dangerous situations and possible eye
injury to yourself and to your colleagues.
Always use protective goggles with minimum OD6 when working on the
ODF_HP, on the fibers that connect to the ODF_HP, and on any parts of
the system that carry OFA_R signals. Inspect the goggles for integrity
(scratches, broken lenses, and any other type of damage); replace the
goggles if in doubt.
Work on the ODF_HP must be carried out only in a restricted access area.
Only people trained in laser safety may be allowed to enter the work area.
Place warning labels alongside the connectors of the fibers that carry
OFA_R signals, in particular on the ODF_HP front panel and near the
connectors, as follows:
HAZARD LEVEL 3B.
DO NOT DISCONNECT UNDER OPERATION.
Connection instructions
Before you start:
1. Use a microscope to check that the ODF_HP fiber tray connectors and the
mating fiber connectors are clean.
2. Bring the ends of the fibers to be interconnected at the ODF_HP to the
level of the ODF_HP: the fibers terminated in connectors must be routed
along the right-hand side of the rack, and fibers to be spliced along the
left-hand side.
3. Familiarize yourself with the items identified in the following figures.
4. Read the ODF_HP and OFA_R specific safety instructions.
7-14
417006-2304-0H3-B02
3. Open the lid of the fiber tray (see internal details in the following figure).
4. Route each fiber to be spliced to a pigtail through the fiber harness exit into
the ODF_HP.
5. Route each fiber to the splices comb, as shown in the previous figure. Make
sure to leave enough slack.
6. Splice the fiber to the pigtails connecting to the prescribed connector in
accordance with the site installation plan. Record the fiber identification
data on the label located on the fiber tray lid.
417006-2304-0H3-B02
7-15
7. Repeat the process until all the fibers have been spliced.
8. Form the fibers into a harness, and secure the harness with cable ties as
shown in the following figure.
Figure 7-9: Fastening the fiber harness to the exit of the fiber tray
7-16
417006-2304-0H3-B02
417006-2304-0H3-B02
7-17
7. Secure the cable connector to the module connector by means of the two
cable connector screws. Tighten the screws by hand. If the screws cannot
be reached with your bare hand, use an adjustable-torque flatblade
screwdriver (maximum blade size 0.6). Set the tightening torque to 40-44
Newton-cm.
7. Secure the cable connector to the module connector by means of the two
cable connector screws. Tighten the screws by hand. If the screws cannot
be reached with your bare hand, use an adjustable-torque flatblade
screwdriver (maximum blade size 0.6). Set the tightening torque to 40-44
Newton-cm.
7-18
417006-2304-0H3-B02
417006-2304-0H3-B02
7-19
7. Secure the cable connector to the mating connector by means of the two
cable connector screws. Tighten the screws by hand. If the screws cannot
be reached with your bare hand, use an adjustable-torque flatblade
screwdriver (maximum blade size 0.6). Set the tightening torque to 40-44
Newton-cm.
Use cable ties as required to fasten the cables to the rack side rails.
CAUTION: Exerting excessive tightening torque to secure
the cable connector may damage the xECB.
7-20
417006-2304-0H3-B02
417006-2304-0H3-B02
7-21
Suitable standard Ethernet station cables are available from many sources.
Category 3 or better cables must be used. In any case, the length of the cables
must not exceed the maximum recommended for the cable type and hub port in
use (up to a few dozens of meters or feet).
Management cables are run from the workstation to the MAIN MNG and
PROT MNG ports on the MECP card installed in the XDM platform.
Protective components for the power supply and hard drive disks are also
recommended, and included in the following connection procedure description.
7-22
417006-2304-0H3-B02
Route the cables from the workstation to the MECP card on the designated
GNE.
The management network connection can either be direct from the
workstation to the GNE, or via a switch and through the internal IP
Ethernet network onsite, as illustrated in the following figure.
417006-2304-0H3-B02
7-23
7-24
417006-2304-0H3-B02
8
Commissioning Tests
In this chapter:
Overview ......................................................................................................... 8-1
Tools and Equipment ....................................................................................... 8-2
Prerequisites .................................................................................................... 8-3
Site Commissioning Tests ............................................................................... 8-5
Network Commissioning ............................................................................... 8-10
Overview
After completing the installation and preliminary configuration of a new
network, a formal commissioning test procedure should be followed to ensure
the network has been properly installed and operates according to
specifications.
The Field Engineering Department of ECI's Transport Networking Division
usually prepares detailed commissioning test procedures for each specific
project, as well as the related acceptance forms.
The procedures in this section serve as the basis for the preparation of specific
commissioning tests for any particular network.
417006-2304-0H3-B02
8-1
Commissioning Tests
If problems are detected during the tests, refer to Troubleshooting (page 9-11)
for instructions that will help you identify the source of the problem and take
corrective actions.
NOTES:
Data transmission test equipment for testing GbE and 10/100 Mbps
transmission performance
Multimeter
8-2
417006-2304-0H3-B02
Commissioning Tests
In general, you can use any equipment model meeting the applicable
international standards and having satisfactory measurement accuracy over the
range of operating parameters and environmental conditions that apply to the
network.
In addition to test equipment, make sure that the tools and materials used for
equipment installation are also available during the commissioning test
procedures.
Prerequisites
Management Requirements
Before performing the commissioning test procedures, it is necessary to set up
the management network needed to control the installed equipment. The
management network must include the functionality of ECI's network
management system.
When the network also has SYNCOM equipment, the XDM management
network may be integrated within the SYNCOM management network. For a
description of XDM integration in SYNCOM networks, see Integrating XDM
equipment in SYNCOM networks (page D-1).
417006-2304-0H3-B02
8-3
Commissioning Tests
Customer Assistance
The commissioning tests perform all the tests that can be done in the customer's
network.
You may need to provide certain specific parameters to integrate the network
into existing operations. In particular, you may have to provide IP addresses for
the management of the network's equipment. Two types of IP addresses can be
used:
For its own purposes, including internal XDM IP addressing, ECI uses the
following IP Class C networks:
192.168.10.0
192.168.11.0
192.68.1.0
192.9.90.0
8-4
417006-2304-0H3-B02
Commissioning Tests
3. Measuring optical levels (page 8-8). Use the reference data in the XDM
System Specification.
4. Measuring signals at monitoring points.
5. Performing the platform power-on test procedure (page 8-10).
Any problems detected during the site commissioning tests must immediately
be corrected before proceeding to other commissioning tests.
Card/Module type
Slot
Boot version
Serial number
1
2
3
4
5
6
417006-2304-0H3-B02
8-5
Commissioning Tests
NOTES:
Make sure that the boot version of each card matches the
embedded version.
If the equipment is already connected to a management
station, you may use the Inventory window to collect the
information and print the relevant data. Refer to the ECI
management system user's manual for detailed
instructions.
8-6
417006-2304-0H3-B02
Table 8-2:
Commissioning Tests
No.
Description of inspection/check
2, 34, 45, 52, 140, 155 Mbps tributary cables installation and
routing between the shelf connector panel and the DDF
10
___V
11
___V
12
Shelves power-on
13
14
15
16
17
18
19
20
21
417006-2304-0H3-B02
Results
8-7
Commissioning Tests
Card type
Port (1 to 16 or
lower/upper)
Wavelength
Optical transmit
level (dBm)
Receive level
(dBm)
The measured power levels must be evaluated against two types of criteria:
If necessary, contact ECI's Field Engineering Department for relevant port and
optical transceiver plug-in specifications and network planning data. An OK
result means that the port meets both criteria.
To minimize the number of measurements, it is usually sufficient to measure
only the optical levels at the transmit and receive ports of I/O cards,
transponders, and optical amplifiers installed in each platform. A good port
receive level also indicates that the components in the optical path up to that
port are properly connected and operate normally. If the result is not
satisfactory, make the additional measurements at all the other ports along the
optical signal paths.
8-8
417006-2304-0H3-B02
Commissioning Tests
Card/Module
PIO2_21, PIO2_84
MO_OFA_M/OFA_M
cards (all types)
MO_OFA_HBC
MO_OFA_PHBC
MUX
417006-2304-0H3-B02
8-9
Commissioning Tests
Note that the SIO1&4B and SIO164 cards do not include any physical
monitoring points. Optical Rx and Tx power levels for the SIO1&4B and
SIO164 cards are monitored through the EMS-XDM management system.
Refer to the EMS-XDM User Manual for more information.
Network Commissioning
SDH Network Commissioning Tests
The SDH network commissioning includes functional tests that check network
operation at the PDH/SDH level to ensure its functional objectives are
achieved.
Perform these tests only after the site acceptance tests have successfully been
completed.
8-10
Framing
Unframed
Coding
HDB3
Pattern
215-1 PRBS
Signal rate
Timing
Received clock
Inject error
Code error
417006-2304-0H3-B02
Commissioning Tests
Unframed
Coding
HDB3
Pattern
215-1 PRBS
Signal rate
Timing
Received clock
Inject error
Code error
Framed
Coding
Pattern
215-1 PRBS
Signal rate
Timing
Received clock
Inject error
Code error
Mapping
Framing
Off
Pattern
223-1 PRBS
Timing
Received clock
Inject error
Code error
417006-2304-0H3-B02
8-11
Commissioning Tests
Mapping
Framing
Off
Pattern
223-1 PRBS
Timing
Received clock
Inject error
Code error
Test Sequence
The list of tests performed at the network commissioning stage depends on the
network functionality. Procedures for the following tests are listed below:
8-12
417006-2304-0H3-B02
Commissioning Tests
Test procedure
1.
2.
3.
4.
417006-2304-0H3-B02
Expected results
8-13
Commissioning Tests
Test procedure
1.
2.
Disconnect the optical fiber from The management station receives a LOS
the receive input connector of the alarm at the SPI level of the
port to be tested.
corresponding optical port. Additional
alarms caused by the LOS condition also
After completing the test,
appear.
reconnect the optical fiber.
3.
Expected results
8-14
417006-2304-0H3-B02
Commissioning Tests
No.
Test procedure
1.
2.
3.
4.
5.
6.
7.
417006-2304-0H3-B02
Expected results
8-15
Commissioning Tests
8-16
No.
Test procedure
Expected results
1.
2.
3.
4.
5.
6.
7.
8.
9.
417006-2304-0H3-B02
Commissioning Tests
Stability Test
The purpose of this test is to verify that the XDM network carries traffic in
accordance with the ITU-T standards.
No.
Test procedure
1.
2.
3.
4.
417006-2304-0H3-B02
Expected results
8-17
Commissioning Tests
8-18
No.
Test procedure
1.
2.
3.
4.
5.
Expected results
417006-2304-0H3-B02
Commissioning Tests
Test procedure
1.
2.
3.
4.
5.
417006-2304-0H3-B02
Expected results
8-19
Commissioning Tests
8-20
No.
Test procedure
Expected results
1.
2.
3.
4.
5.
Check that the trail carries traffic The orange PROT indicator on the
properly on the protection
electrical interface module lights up.
(standby) card.
6.
417006-2304-0H3-B02
Commissioning Tests
Test procedure
Expected results
1.
2.
3.
4.
5.
417006-2304-0H3-B02
8-21
Commissioning Tests
8-22
No.
Test procedure
Expected results
1.
2.
3.
4.
5.
6.
417006-2304-0H3-B02
Commissioning Tests
Near-end loopback
Forced MS-RDI
No.
Test procedure
1.
2.
3.
4.
5.
6.
7.
417006-2304-0H3-B02
Expected results
8-23
Commissioning Tests
Test procedure
1.
2.
3.
Expected results
8-24
417006-2304-0H3-B02
Commissioning Tests
No.
Test procedure
1.
2.
3.
Expected results
Test procedure
1.
Select two sites with Cisco ATA 186, The Cisco ATA 186 in site B rings.
and dial from site A to site B.
2.
417006-2304-0H3-B02
Expected results
8-25
Commissioning Tests
Test procedure
1.
2.
3.
4.
Expected results
5.
8-26
417006-2304-0H3-B02
Commissioning Tests
Data/Payload:
Random
Destination address:
Source address:
Line rate:
Test Sequence
The list of tests performed at the data network commissioning stage depends on
the network functionality. Procedures for the following tests are listed below:
Stability
Alarm handling
417006-2304-0H3-B02
8-27
Commissioning Tests
Test procedure
Expected results
1.
2.
3.
4.
5.
Inject traffic in accordance with the When calculating the latency, take into
assigned bandwidth (one VC-12 =
consideration:
2.048 Mbps), and measure
The measured latency is measured for
throughput and latency for the
the forward and return paths. The
following frame sizes: 64 bytes, 128
latency for a single path is half the
bytes, 256 bytes, 512 bytes, 1024
total.
bytes, 1280 bytes, and 1518 bytes.
The latency result depends on the
throughput results. For example, when
testing at 10 Mbps and the throughput
is 40%, the latency test is made for 4
Mbps (the bandwidth of two VC-12s
is 4 Mbps).
NOTES:
8-28
417006-2304-0H3-B02
Table 8-5:
Commissioning Tests
256
bytes/
frame
512
bytes/
frame
1024
bytes/
frame
1280
bytes/
frame
1518
bytes/
frame
Throughput
Latency
Test procedure
1.
2.
3.
4.
Table 8-6:
Frame size
Expected results
128
bytes/
frame
256
bytes/
frame
512
bytes/
frame
1024
bytes/
frame
1280
bytes/
frame
1518
bytes/
frame
Frame rate
(% MFR)
100%
417006-2304-0H3-B02
8-29
Commissioning Tests
Test procedure
Expected results
1.
2.
3.
4.
5.
6.
Stability Test
The purpose of this test is to check that no errors occur in the network for a
defined period of time.
8-30
No.
Test procedure
1.
2.
3.
4.
5.
Expected results
417006-2304-0H3-B02
Commissioning Tests
No.
Test procedure
Expected results
1.
2.
3.
4.
5.
Network Configuration
Before starting the optical network commissioning tests, configure the XDM
equipment for operation according to the specific customers requirements and
for using the network management station assigned to manage the XDM
equipment.
417006-2304-0H3-B02
8-31
Commissioning Tests
Connect the test equipment to each transponder installed at one end of the
tested transmission path. The test equipment must be configured to operate
at the transponder transmission rate (for example, STM-16 when connected
to a TRP25, and STM-64 when connected to a TRP10).
Connect a short section of patch fiber between the transmit and receive
ports of the corresponding transponder located at the other end of the tested
path to form an optical loopback. It is recommended to insert an
appropriate attenuator in the loopback path to ensure that the received
signal is within the normal operating range of the port.
When testing sensitivity and LOS, modify the test setup to include a variable
optical attenuator. The resulting test setup is shown in the following figure.
Figure 8-2: Test setup modified to support LOS and sensitivity tests
After completing the tests on a specific transponder, make sure to restore the
original connections.
8-32
417006-2304-0H3-B02
Commissioning Tests
Test procedure
Expected results
1.
2.
417006-2304-0H3-B02
8-33
Commissioning Tests
Test procedure
1.
2.
3.
4.
5.
Expected results
8-34
No.
Test procedure
Expected results
1.
Disconnect the optical fiber from An SPI-LOS alarm appears for each
the receive input (Rx line) of
optical card, together with other alarms
each optical card.
caused by the disconnection.
417006-2304-0H3-B02
Commissioning Tests
Test procedure
1.
2.
3.
4.
5.
6.
417006-2304-0H3-B02
Expected results
8-35
Commissioning Tests
8-36
No.
Test procedure
1.
2.
3.
4.
5.
Expected results
417006-2304-0H3-B02
Commissioning Tests
Maintenance Test
The purpose of this test is to verify that maintenance actions can be performed
on XDM platforms using the management system.
This procedure tests the following functions:
Manual switch
Forced switch
Switch lockout
No.
Test procedure
1.
2.
3.
4.
5.
6.
7.
8.
417006-2304-0H3-B02
Expected results
8-37
Commissioning Tests
No.
Test procedure
Expected results
9.
10.
11.
8-38
No.
Test procedure
Expected results
1.
2.
3.
4.
417006-2304-0H3-B02
Commissioning Tests
Test procedure
Expected results
1.
2.
Activate the PING feature for the Make sure packet loss for all three XDM
three NEs simultaneously.
NEs is less than 1%.
Security Test
The purpose of this test is to verify that the user can define a user with different
capabilities.
No.
Test procedure
1.
2.
3.
Expected results
Test procedure
Expected results
1.
2.
417006-2304-0H3-B02
8-39
Commissioning Tests
Test procedure
1.
2.
Expected results
Test procedure
1.
2.
Expected results
8-40
No.
Test procedure
Expected results
1.
2.
3.
4.
5.
6.
417006-2304-0H3-B02
Commissioning Tests
Test procedure
1.
2.
Expected results
RDR Test
The purpose of this test is to verify that the RDR station replicates the NMS
database and works properly.
No.
Test procedure
1.
2.
3.
Expected results
Test procedure
1.
2.
3.
4.
417006-2304-0H3-B02
Expected results
8-41
Commissioning Tests
Go-Global Test
The purpose of this test is to verify that the Go-Global software operates
properly.
No.
Test procedure
1.
2.
3.
Expected results
Orderwire Test
The purpose of this test is to verify that the orderwire network operates
properly.
No.
Test procedure
Expected results
1.
2.
3.
4.
5.
8-42
No.
Test procedure
1.
2.
3.
Expected results
417006-2304-0H3-B02
9
Maintenance
In this chapter:
Overview ......................................................................................................... 9-1
Required Test Equipment, Tools, and Materials ............................................. 9-2
Preventive Maintenance .................................................................................. 9-2
Troubleshooting ............................................................................................. 9-11
Replacing a Network Element ....................................................................... 9-40
Replacing Cards, Modules, Fans, and Other Components ............................ 9-43
Overview
This chapter describes the maintenance procedures for XDM equipment.
Personnel involved in maintenance must be thoroughly familiar with the safety
issues (see "Installing XDM-500: Before You Start Safety Guidelines" page
1-1).
NOTE: Unless otherwise indicated, the procedures described
in these sections apply to all XDM platforms and to both
SDH and SONET.
417006-2304-0H3-B02
9-1
Maintenance
Preventive Maintenance
This section describes the XDM preventive maintenance procedures to be
performed periodically by network administrators. The purpose of these
procedures is to ensure optimal and uninterrupted operation of your network.
The information presented in this section includes:
9-2
417006-2304-0H3-B02
Legend:
Table 9-1:
Item
Maintenance
W weekly
M monthly
Q quarterly
Inspection/Check
Intervals
W
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
417006-2304-0H3-B02
X
X
X
9-3
Maintenance
Item
Inspection/Check
Intervals
W
12.
13.
Check that all card and module LEDs turn on when the
LED TEST pushbutton on the MECP panel is pressed.
14.
15.
16.
Procedure
Should be performed
Check version
correspondence.
Check performance.
9-4
Comments
417006-2304-0H3-B02
Maintenance
Procedure
Should be performed
Check switching to
protection.
Comments
Traffic-affecting
Inspection/Check
Intervals
W
1.
2.
3.
4.
417006-2304-0H3-B02
X
X
X
9-5
Maintenance
Item
Inspection/Check
Intervals
W
9-6
5.
6.
7.
8.
9.
10.
11.
12
13.
Check that all card and module LEDs turn on when the
LED TEST pushbutton on the MECP panel is pressed.
14.
417006-2304-0H3-B02
Maintenance
3. Cold water rinse: Under normal service conditions, the foam media used
in the filters require no oily adhesives. Therefore, collected dust and dirt
can be washed away using a standard hose nozzle with plain water. Stand
the filter until completely dry and free of moisture, and return to service.
4. Immersion in warm soapy water: Where stubborn airborne dirt is present,
the filter may be dipped in a solution of warm water and mild detergent.
Then simply rinse in clear water, stand until completely dry and free of
moisture, and return to service.
The recommended method is No. 4, as it ensures thorough cleaning of all types
of contaminants under any reasonable service conditions.
417006-2304-0H3-B02
9-7
Maintenance
Cleaning Procedure
For the procedure steps, refer to the following figure.
NOTE: The air filter can be removed and reinstalled while
6. Insert the clean filter in the holding frame and reinstall the front panel.
9-8
417006-2304-0H3-B02
Maintenance
EMS-XDM Checklists
Weekly checklist
Procedure
Date
Result
Date
Result
Date
Result
Monthly checklist
Procedure
Quarterly checklist
Procedure
417006-2304-0H3-B02
9-9
Maintenance
LightSoft Checklists
Weekly checklist
Procedure
Date
Result
Quarterly checklist
Procedure
Date
Result
Hardware Checklists
Weekly checklist
Procedure
Date
Result
Monthly checklist
Procedure
Date
Result
9-10
417006-2304-0H3-B02
Maintenance
Quarterly checklist
Procedure
Date
Result
Troubleshooting
The purpose of onsite troubleshooting is to identify the hardware causing the
malfunction and return the equipment to normal operation as soon as possible.
Troubleshooting is usually initiated in response to one of the following
conditions:
This chapter assumes familiarity with the XDM and with SDH and DWDM
equipment, and with the LightSoft and EMS-XDM management stations. Refer
to the respective user manuals for details on the various capabilities of the
management stations, and for instructions on performing the desired activities.
The following sections provide procedures for performing onsite
troubleshooting for various trouble categories as well as for specific
subsystems, such as OADMs and Mux/DeMux subsystems. For each category,
you will find a troubleshooting table that provides the instructions for
identifying the problem.
417006-2304-0H3-B02
9-11
Maintenance
9-12
417006-2304-0H3-B02
Maintenance
No.
Symptoms
Probable cause
1.
Green ACTIVE
indicator off.
Defective
card/module
2.
417006-2304-0H3-B02
Corrective measures
9-13
Maintenance
No.
Symptoms
Probable cause
Corrective measures
Orange (traffic
carrying) indicator
off (when indicator
supported).
9-14
417006-2304-0H3-B02
Maintenance
Table 9-5:
No.
Symptoms
Probable cause
1.
Green transceiver
state indicator off.
Corresponding
optical transmitter
may have been
turned off by the
ALS function (see
note below).
2.
Transceiver state
indicator lights in
red.
Test equipment
connected to the
monitoring connector
of the corresponding
plug-in.
Defective
transceiver.
417006-2304-0H3-B02
Corrective measures
9-15
Maintenance
9-16
No.
Symptoms
Probable cause
Corrective measures
1.
Green ACTIVE
indicator off.
Defective
card/module
2.
Red FAIL
Defective
indicator not
card/module
turning off after
software download
(following
power-on and
resetting).
417006-2304-0H3-B02
Maintenance
No.
Symptoms
Probable cause
3.
Orange PROT
indicator lights.
Problem on protected
card/module
Corrective measures
Table 9-7:
No.
Symptoms
Probable cause
1.
Green ACTIVE
indicator off.
Defective
card/module
417006-2304-0H3-B02
Corrective measures
9-17
Maintenance
9-18
No.
Symptoms
Probable cause
Corrective measures
2.
Red FAIL
Defective
indicator not
card/module
turning off after
software download
(following
power-on and
resetting).
3.
ERROR indicator
lights.
Incorrect channel
Defective
card/module
417006-2304-0H3-B02
Maintenance
No.
Symptoms
Probable cause
1.
Green ACTIVE
indicator on base
card off.
Defective card
2.
Red FAIL
Defective card
indicator on base
card not turning off
after software
downloading
(following
power-on and
resetting).
3.
Orange TRAFFIC
CARRYING
indicator on base
card off.
4.
Green LINK
STATE indicator
of an Ethernet
optical port or
ME_8/ME_14
electrical port off.
Problem related to
port
417006-2304-0H3-B02
Corrective measures
9-19
Maintenance
No.
Symptoms
Probable cause
LINK STATE
indicator of an
ME_8/ME_14
10/100BaseT
Ethernet port off.
Problem related to
port
Orange
Problem related to
ACTIVITY
port
indicator of an
Ethernet port lights
steadily.
Corrective measures
9-20
No.
Symptoms
Probable cause
Corrective measures
1.
Green ACTIVE
indicator on base
card off.
Defective card
2.
Red FAIL
indicator on base
card not turning
off after software
downloading
(following
power-on and
resetting).
Defective card
417006-2304-0H3-B02
Maintenance
No.
Symptoms
Probable cause
3.
Orange (traffic
carrying)
indicator on base
card off.
Card not
configured to carry
traffic
4.
Red FAIL
indicator of
plug-in module
lights.
Defective plug-in
module
5.
6.
7.
Link indicator of
GbE port off.
417006-2304-0H3-B02
Link is down
Corrective measures
9-21
Maintenance
9-22
No.
Symptoms
Probable cause
Corrective measures
1.
Green ACTIVE
indicator on base
card off.
Defective card
2.
Red FAIL
indicator on base
card not turning
off after software
downloading
(following
power-on and
resetting).
Defective card
3.
Orange (traffic
carrying)
indicator on base
card off.
4.
5.
Orange (activity)
indicator of an
Ethernet port
lights steadily.
Problem related to
port
417006-2304-0H3-B02
Maintenance
wing locking the card extractor handle. The card will not
operate if the reset control is not closed. If the card is not
working, be sure to verify that the reset control is closed
properly. After inserting the card and securing it in its slot
with the extractor handle, turn the reset control
counter-clockwise to enable the card to start operating.
Symptoms
Probable cause
1.
Green ACTIVE
indicator on base
card off.
Defective card
2.
Red FAIL
Defective card
indicator on base
card not turning off
after software
downloading
(following
power-on and
resetting).
3.
Orange (traffic
carrying) indicator
on base card off.
417006-2304-0H3-B02
Corrective measures
9-23
Maintenance
No.
Symptoms
Probable cause
4.
Orange, Green, or
Blue (link state)
indicator of an
Ethernet optical
port or ME16
electrical port is
off.
Problem related to
specific port
5.
Orange (activity)
Problem related to
indicator of an
port
Ethernet port lights
steadily.
Corrective measures
rotable wing locking the card extractor handle. The card will
not operate if the reset control is not closed. If the card is not
working, be sure to verify that the reset control is closed
properly. After inserting the card and securing it in its slot
with the extractor handle, turn the reset control
counter-clockwise to enable the card to start operating.
9-24
417006-2304-0H3-B02
Maintenance
Symptoms
Probable cause
1.
Green ACTIVE
indicator on base
card off.
Defective card
2.
Red FAIL
Defective card
indicator on base
card not turning off
after software
downloading
(following
power-on and
resetting).
3.
Orange (traffic
carrying) indicator
on base card off.
Card not
configured to carry
traffic
4.
Loss of input
signal for ADD
unit
417006-2304-0H3-B02
Corrective measures
9-25
Maintenance
No.
Symptoms
Probable cause
5.
Loss of input
signal for DROP
unit
Corrective measures
9-26
417006-2304-0H3-B02
Maintenance
No power light.
No card activity
light.
No link status
lights.
No link activity
lights.
Built-in tests
The Aurora-G embedded software performs a series of built-in tests to verify
that the Aurora-G hardware components are functioning properly and operating
under the correct conditions. Some of the BIT procedures are performed when
the card's software boots. Some BIT procedures are performed on a periodic
basis. The tests that run on a periodic basis are non-service affecting.
If any of the BIT procedures fail, a card failure alarm is generated. Details
about the failure are displayed in the EMS-Aurora Alarms view and, if
configured to do so, the alarms are sent to a syslog server.
417006-2304-0H3-B02
9-27
Maintenance
Memory modules
Compact flash
Real-time clock
Diagnostic codes
When the Aurora-G powers up, the diagnostic code LED displays 88 to verify
that the diagnostic display segments are functioning. As the Aurora-G cycles
through the built-in test sequence, the corresponding diagnostic code is
displayed. After the tests are completed successfully, the diagnostic code
display is solidly illuminated with the code 00.
If a test fails, the card failure LED illuminates, which indicates that the
Aurora-G is in an error state. If the Aurora-G fails to boot properly, make a
note of the error code and contact customer support.
If the failure occurs after the serial port has been initialized, a card failure
alarm is sent to EMS-Aurora and a text message describing the boot failure is
displayed on the terminal. A message is also sent to the syslog server if the card
has been configured to send alarms to a syslog server.
The diagnostic code display indicates the number of the failed test. The
following table lists the test error codes.
Table 9-14: Diagnostic codes
Code
Built-in test
Terminal output
88
None
01
Bootrom CRC
None
02
None
03
None
04
None
05
None
06
RDRAM test
None
Code authentication
.... FAILED
07
9-28
417006-2304-0H3-B02
Code
Maintenance
Built-in test
Terminal output
08
CAM test
09
00
Up and operational
Management access
Table 9-15: Management access troubleshooting
Symptom
Administrator
password is forgotten
or lost.
The management
workstation cant
communicate with the
Aurora-G.
Aurora-G is not
sending SNMP objects
to the management
workstation.
417006-2304-0H3-B02
9-29
Maintenance
Symptom
Configuration
Table 9-16: Configuration troubleshooting
Symptom
Aurora-G configuration
settings revert to their
previous setting after
the unit is rebooted.
9-30
417006-2304-0H3-B02
Maintenance
Traffic
Table 9-17: Traffic troubleshooting
Symptom
Cannot establish a
link.
417006-2304-0H3-B02
9-31
Maintenance
Certificates
Table 9-18: Certificate troubleshooting
Symptom
Issue the debug crl command and look for the following:
Verify that the URL for the CRL server is correct.
Check that the dns command is configured.
Make sure that the CRL URL is in the correct field in
the peers certificate (in the CRL distribution point
field).
Card failure
Table 9-19: Card failure troubleshooting
9-32
Symptom
417006-2304-0H3-B02
Maintenance
Symptoms
Probable cause
1.
Green ACTIVE
indicator on base
card off.
Defective card
2.
3.
Orange (traffic
carrying) indicator
on base card off.
417006-2304-0H3-B02
Corrective measures
9-33
Maintenance
Symptoms
Probable cause
1.
9-34
Corrective measures
417006-2304-0H3-B02
Maintenance
No.
Symptoms
2.
417006-2304-0H3-B02
Probable cause
Corrective measures
9-35
Maintenance
9-36
No.
Symptoms
Probable
cause
Corrective measures
xRAP-D,
xRAP-B,
xRAP-HP, or
miniRAP
POWER ON
indicator on
Equipment
problem
417006-2304-0H3-B02
Maintenance
Probable
cause
Corrective measures
No.
Symptoms
2.
3.
xINF FAIL
Technical
indicator lights failure in the
corresponding
unit
417006-2304-0H3-B02
9-37
Maintenance
9-38
Symptoms
Probable cause
Corrective measures
Switching to
standby TMU
Technical failure
Missing T3 external
reference signal
Missing T4 external
reference signal
Loss of reference
clock source
provided by a
tributary
417006-2304-0H3-B02
Maintenance
Troubleshooting Management
Communication
When it is not possible for the management station to manage an XDM
platform, use the following table to identify the cause of the problem.
NOTE: Whenever problems are detected during
Probable cause
Management
traffic path
Defective card in
management traffic
path
Problem in
transmission path
Other problems
417006-2304-0H3-B02
Corrective measures
9-39
Maintenance
9-40
417006-2304-0H3-B02
Maintenance
417006-2304-0H3-B02
9-41
Maintenance
Expected results
9-42
417006-2304-0H3-B02
Maintenance
417006-2304-0H3-B02
9-43
Maintenance
4. Insert the replacement circuit breaker into the circuit breaker sockets of the
corresponding xRAP-D power terminal board, as shown in the following
figures.
5. Reinstall the xRAP-D front cover and fasten it with its two captive screws.
9-44
417006-2304-0H3-B02
Maintenance
2. Identify the faulty circuit breaker and remove it by pulling it straight out of
its socket.
3. Check the replacement circuit breaker ratings against those of the replaced
circuit breaker.
WARNING: For continued protection against risk of fire,
replace only with a circuit breaker of the same type and
rating.
417006-2304-0H3-B02
9-45
Maintenance
4. Insert the replacement circuit breaker into the circuit breaker sockets
located on the corresponding xRAP-HP power terminal board as shown in
the previous figure.
5. Reinstall the xRAP-HP panel and fasten it with its two captive screws.
2. Identify the circuit breaker and remove it by pulling it straight out of its
socket.
3. Check the replacement circuit breaker ratings against those of the replaced
circuit breaker.
WARNING: For continued protection against risk of fire,
replace only with a circuit breaker of the same type and
rating.
9-46
417006-2304-0H3-B02
Maintenance
4. Insert the replacement circuit breaker into the circuit breaker sockets
located on the corresponding xRAP-100 power terminal board, as shown in
the previous figure.
5. Reinstall the xRAP-100 cover and fasten it with its two captive screws.
replace only with the same type and rating of circuit breaker.
4. Insert the replacement circuit breaker into the circuit breaker sockets of the
corresponding miniRAP power terminal board, as shown in the following
figure.
5. Reinstall the miniRAP front cover and fasten it with its two captive screws.
417006-2304-0H3-B02
9-47
Maintenance
417006-2304-0H3-B02
Maintenance
9-49
Maintenance
Replacing Cards
CAUTION: - STATIC SENSITIVE DEVICES
PROPER HANDLING AND GROUNDING
PRECAUTIONS REQUIRED
XDM equipment contains components sensitive to electrostatic
discharge (ESD). To prevent ESD damage, strictly observe all the
precautions listed in Protection against Electrostatic Discharge (page 126). Keep parts and cards in their antistatic packaging material until
you are ready to install them.
The use of an antistatic wrist strap connected to a grounded equipment
frame or rack is recommended when handling cards and modules
during installation, removal, or connection to internal connectors.
Hold the card straight during insertion and removal, and pull or push it
slowly and carefully to avoid touching components located on adjacent
cards.
Do not use excessive torque when tightening the fastening screws of
cards and modules.
9-50
417006-2304-0H3-B02
Maintenance
417006-2304-0H3-B02
9-51
Maintenance
9-52
417006-2304-0H3-B02
Maintenance
417006-2304-0H3-B02
9-53
Maintenance
9-54
417006-2304-0H3-B02
Maintenance
417006-2304-0H3-B02
9-55
Maintenance
7. Push the card in until it mates the chassis connectors. If you feel resistance
before the connectors are mated, pull the card out and repeat the procedure.
8. Press the ends of the two extractor handles to fully insert the card.
9. Push the card reset control and rotate it counter-clockwise to lock the lower
extractor handle.
417006-2304-0H3-B02
Maintenance
417006-2304-0H3-B02
9-57
Maintenance
9-58
417006-2304-0H3-B02
Maintenance
417006-2304-0H3-B02
9-59
Maintenance
9-60
417006-2304-0H3-B02
Maintenance
417006-2304-0H3-B02
9-61
Maintenance
9-62
417006-2304-0H3-B02
A
XDM Accessories
In this appendix:
Typical Installation Setup ............................................................................... A-2
Rack Alarm Panel Power and Alarm Connection Options ............................. A-4
Rap Features ................................................................................................... A-5
xRAP-D .......................................................................................................... A-7
xRAP-B ........................................................................................................ A-13
xRAP-HP ...................................................................................................... A-16
xRAP-100 ..................................................................................................... A-19
miniRAP ....................................................................................................... A-22
FST ............................................................................................................... A-25
Heat Buffer ................................................................................................... A-26
Cable and Fiber Guiding Accessories .......................................................... A-26
Optical Distribution Frames (ODFs) ............................................................ A-29
Digital Distribution Frames (DDF) .............................................................. A-33
417006-2304-0H3-B02
A-1
XDM Accessories
xRAP-D, xRAP-B, and xRAP-HP are each able to fully support two
shelves. The xRAP-HP also has the capability to chain alarm
monitoring lines from a third shelf.
xRAP-100 supports up to four XDM shelves, one of them a fully
equipped XDM-1000.
miniRAP supports one XDM shelf (not high-power).
In addition to the space needed for installing the xRAP unit, leave at
least 50 mm (2 in.) free space under the xRAP unit for routing cables.
Fiber Storage Trays (FSTs) for storing optical fiber. The FSTs are 1 U (44
mm/1.75 in.) high units that can store up to 48 2-mm (.08-in.) optical
fibers, each up to 2.5 meters (2.75 yards) long.
In general, FSTs are installed under the RAP. However, when there is not
enough space in the rack, install them just above the rack. For this purpose
ECI offers extendable installation rails.
A-2
Cable guide. The cable guide is used to help route the coaxial cables neatly,
and is used in addition to the standard rack cable guides attached to the
rack side rails.
417006-2304-0H3-B02
XDM Accessories
417006-2304-0H3-B02
A-3
XDM Accessories
A-4
417006-2304-0H3-B02
XDM Accessories
Rap Features
The following table lists the characteristics of the available xRAPs:
Table A-1: RAP features
Features
miniRAP
xRAP-100
PRAP
xRAP-D
xRAP-B (EOL)
xRAP-HP (EOL)
1 + 3 19
1.2 KW
3.2 KW
4.8 KW
4.5 KW
4.5 KW
4 KW
Severity alarms 20
---
---
---
---
---
17
417006-2304-0H3-B02
A-5
Features
XDM Accessories
miniRAP
xRAP-100
---
---
Fixed, two
outputs per
platform, total
eight per
xRAP-100
Connector type
for power cable between xINF and
xRAP (xRAP side)
Cable size between xRAP and batteries
(connects with terminal lugs)
21
xRAP-D
xRAP-B (EOL)
xRAP-HP (EOL)
5 pin connector
5 pin connector
5 pin connector
Terminal lug
35 mm2
(1+1)
25 mm2
(1+1), (1+1), & (1+1)
Three inputs for side
A and three inputs for
side B
25 mm2 25
(1+1) & (1+1)
Two inputs for side A
and two inputs for side
B
50 mm2
(1+1)
50 mm2
(1+1)
35 mm2
(1+1)
PRAP
21
A-6
417006-2304-0H3-B02
XDM Accessories
xRAP-D
The xRAP-D is a power distribution and alarm panel for XDM platforms
installed in racks. The xRAP-D performs the following main functions:
The xRAP-D has four 5-pin DC output connectors for supplying redundant
power to any platform in the XDM-1000 or XDM-100 family of products.
The maximum power supplied to each XDM platform is up to 2250 W, in
accordance with the platform type and version.
417006-2304-0H3-B02
A-7
XDM Accessories
Note that with the default configuration, the power cables from the user's
power supply sources to the xRAP-D do not have to be more than 25 mm2
thick, and the circuit breakers do not have to be more than 55A, because the
maximum power consumption per cable is never more than 2250 W.
Previous xRAP units used a single heavy duty power cable to supply power
for up to two XDM platforms. The xRAP-D enables independent power
delivery to two shelves through separate cables, enabling use of thinner
cables and smaller circuit breakers. The xRAP-D was developed in
response to the needs of customers who are not able to support large
aggregate power feeding requirements when supporting two XDM
platforms.
NOTE: Users who prefer to work with a single power cable
The nominal DC power voltage is -48 VDC, ranging to -72 VDC. The
internal circuits of the xRAP-D are powered whenever at least one power
source is connected. The presence of DC power within the xRAP-D is
indicated by a POWER ON indicator.
Each DC power circuit of each platform is protected by a circuit breaker
that also serves as a power on/off switch for the corresponding circuit. The
required circuit breakers are included in the installation parts kit supplied
with the XDM-500 shelves, and therefore their current rating is in
accordance with the order requirements.
A-8
417006-2304-0H3-B02
XDM Accessories
Bay alarm indications. The xRAP-D includes four alarm indicators, one
for each alarm severity. When alarms of different severities are received
simultaneously, the corresponding alarm indications light simultaneously.
A buzzer is activated whenever a Critical alarm is present in XDM
platforms connected to the xRAP-D.
417006-2304-0H3-B02
A-9
XDM Accessories
The following figure shows the front panel of the xRAP-D, and the table lists
the functions of the front panel components corresponding to the figure callout
numbers.
A-10
No.
Designation
Function
SOURCE A
TEST
POWER ON
CRITICAL
MAJOR
MINOR
WARNING
Buzzer
(concealed under
cover)
SOURCE B
417006-2304-0H3-B02
XDM Accessories
The xRAP-D connectors are located on the circuit board, as shown in the
following figure. The table lists the connector functions. The index numbers in
the table correspond to those in the figures.
Designation
Function
1, 2
ALARMS
4, 5
SHELF 1 and
SHELF 2
Alarm signals arrive at a SHELF connector on the xRAP unit from two
different connector sources on the XDM platform using a Y-Cable.
A 9-pin connector on the XDM platform labeled xRAP is used for the four
XDM severity alarms. (CRITICAL, MAJOR, MINOR, and WARNING)
417006-2304-0H3-B02
A-11
XDM Accessories
A Y-Cable is used to link these two connector sources to the single SHELF
connection point on the xRAP, as illustrated in the following figure.
The xRAP-D supports up to eight input plus eight output external alarms.
These alarms are by default allocated four to each platform. ECI offers the
option, when working with a single XDM-1000 platform, to define up to eight
external input plus eight external output alarms for that XDM-1000 platform.
When working with this configuration, a second XDM platform cannot be
connected to the xRAP-D and a special double-Y alarm connection cable
must be used, as illustrated in the following figure. Contact ECI technical
support for more information.
A-12
417006-2304-0H3-B02
XDM Accessories
xRAP-B
NOTE: The xRAP-B is no longer included in new XDM
deliveries (EOL). This information is included here if needed
for a current installation.
The xRAP-B is a power distribution and alarm panel for XDM platforms
installed in racks. The xRAP-B performs the following main functions:
Bay alarm indications. The xRAP-B includes four alarm indicators, one
for each alarm severity. When alarms of different severities are received
simultaneously, the corresponding alarm indications light simultaneously.
A buzzer is activated whenever a Major or Critical alarm is present in
XDM platforms installed in the rack.
417006-2304-0H3-B02
A-13
XDM Accessories
The following figure shows the front panel of the xRAP-B, and the table lists
the functions of the front panel components corresponding to the figure callout
numbers.
A-14
No.
Designation
Function
SOURCE A
TEST
POWER ON
CRITICAL
MAJOR
MINOR
417006-2304-0H3-B02
XDM Accessories
No.
Designation
Function
WARNING
Buzzer
(concealed under
cover)
SOURCE B
The xRAP-B connectors are located on the circuit board, as shown in the
following figure. The table lists the connector functions. The index numbers in
the table correspond to those in the figures.
Designation
Function
1, 2
Shelves DC input
power
ALARMS
4, 5
SHELF alarms
26
Alarm input lines arrive through the ALARM connector and are connected to the corresponding SHELF
connector.
417006-2304-0H3-B02
A-15
XDM Accessories
xRAP-HP
NOTE: The xRAP-HP is no longer included in new XDM
deliveries (EOL). This information is included here if needed
for a current installation.
The xRAP-HP is a power distribution and alarm panel for any two XDM-500
platforms installed in racks. The xRAP-HP performs the following main
functions:
Bay alarm indications: The xRAP-HP includes four alarm indicators, one
for each alarm severity. At any time, only the indicator corresponding to
the highest unacknowledged alarm severity present in the XDM-500
platforms installed in the rack lights.
A buzzer is activated whenever an unacknowledged alarm is present in
XDM-500 platforms installed in the rack.
A-16
417006-2304-0H3-B02
XDM Accessories
The following figure shows the front panel of the xRAP-HP, and the table lists
the functions of the front panel components corresponding to the figure
callouts.
Designation
Function
SOURCE A
Buzzer
POWER ON
(TEST)
CRITICAL
MAJOR
MINOR
WARNING
SOURCE B
417006-2304-0H3-B02
A-17
XDM Accessories
The following figure shows the xRAP-HP connectors located on the rear side.
Note that if you are using an xRAP-HP unit up to Rev.C01, the unit includes
slide switches used to allocate alarm lines. The following figure shows the
xRAP-HP connectors and slide switches located on the rear side.
The following table lists the xRAP-HP connector functions. The index numbers
in the table correspond to those in the preceding figures.
Table A-7: xRAP-HP connectors
No.
Designation
Function
1, 2, 3
EXTERNAL
Three 25-pin D-type connectors, designated SHELF 1,
ALARM/CONTROL SHELF 2, and SHELF 3, for connecting alarm input and output
lines to XDM-500 platforms and other equipment installed in
the rack.
4, 5, 6
RAP
CONTROL
CONNECTION
8, 9, 10, 11
(up to Rev.C01)
Four slide switches used to route the facility alarm lines to the
input and output lines of the XDM platforms connected to the
xRAP-HP.
417006-2304-0H3-B02
XDM Accessories
xRAP-100
The xRAP-100 is a power distribution and alarm panel for XDM and BG
shelves installed in racks. The xRAP-100 performs the following main
functions:
XDM-50
XDM-100
XDM-500
XDM-40
Any BG shelf
The 5-pin high-power connector can supply power to one of the above
regular shelves, or to one of the following high-power shelves:
XDM-300
XDM-900
XDM-1000
XDM-2000
NOTE: When a regular XDM or BG shelf has to be
connected to the 5-pin connector, use a 5-pin D-type male to
3-pin D-type female adapter cable.
A-19
XDM Accessories
Bay alarm indications: The xRAP-100 includes four alarm indicators, one
for each alarm severity. When alarms of different severities are received
simultaneously, the different alarm indications light simultaneously.
NOTE: BG shelves support only two alarm indications:
Major and Minor.
A buzzer is activated whenever a Major or Critical alarm is present in
XDM shelves connected to the xRAP-100. In case of BG shelves connected
to the xRAP-100, the buzzer is activated whenever a Major alarm is present
in the BG shelves.
The following figure shows the front panel of the xRAP-100, and the table lists
the functions of the front panel components corresponding to the figure callout
numbers.
A-20
No.
Designation
Function
SOURCE A
--
Buzzer
Operates when at least one unacknowledged Major or
(Concealed under Critical alarm is present in the shelves connected to the
cover)
xRAP-100.
TEST
POWER ON
417006-2304-0H3-B02
XDM Accessories
No.
Designation
Function
CRITICAL
MAJOR
MINOR
WARNING
SOURCE B
The xRAP-100 connectors are located on its circuit board, as shown in the
following figure. The table lists the connector functions. The index numbers in
the table correspond to those in the figure.
Designation
Function
1, 2, 3, 4
Shelf alarms
ALARM IN/OUT
417006-2304-0H3-B02
A-21
XDM Accessories
No.
Designation
Function
6, 7, 8
Shelves DC input
power
Shelf DC input,
high power
miniRAP
The miniRAP is a power distribution and alarm panel for low-power XDM
shelves and other low-power communication shelves installed in racks. The
miniRAP supports the following main functions:
Bay alarm indications. The miniRAP has four alarm indicators, one for
each alarm severity. When alarms of different severities are received
simultaneously, the different indicators light simultaneously.
A buzzer is activated when a Major or Critical alarm is present in the shelf
installed in the rack.
A-22
417006-2304-0H3-B02
XDM Accessories
The following figure shows the front panel of the miniRAP, and the table lists
the functions of the front panel components corresponding to the figure callout
numbers.
Designation
Function
SOURCE A
TEST
POWER ON
CRITICAL
MAJOR
MINOR
WARNING
SOURCE B
417006-2304-0H3-B02
A-23
XDM Accessories
The miniRAP connectors are located on its circuit board. The table lists the
connector functions. The index numbers in the table correspond to those in the
figure.
A-24
No.
Designation
Function
1, 4
SEVERITY IN
SEVERITY OUT
417006-2304-0H3-B02
XDM Accessories
FST
The Fiber Storage Tray (FST) is used to store surplus optical fiber. The FST
can hold up to 48 2-mm (.08 in.) fibers, where each stored fiber can be up to
2.5 meters (8.1 feet) long.
The following figure shows a front view of the FST. The Fiber Storage Tray
top view (page A-25) shows a top view of the FST, together with typical paths
to be followed when fibers are inserted for storage in the tray.
Completely, by pressing the release handles at the two sides (to enable
threading the fibers in the tray)
417006-2304-0H3-B02
A-25
XDM Accessories
Heat Buffer
Heat buffers must always be used in the following circumstances:
The heat buffer used for XDM-500 shelves is a 1U high unit installed below
the XDM-500 equipment shelf to provide thermal isolation. The heat buffer is
fastened to the rack rails under the shelf.
The following figure shows a typical XDM-500 heat buffer.
Cable Guide
The cable guides for XDM-500 platforms are used to help neatly route E1
tributary cables connecting to the panels of M2_21 and M2_84 electrical
interface modules.
The cable guide is fastened to the rack side rails just over the top of the lower
card cage. To ease cable insertion, the top bar can be removed by pulling out
two spring-loaded knobs at the two sides.
A-26
417006-2304-0H3-B02
XDM Accessories
417006-2304-0H3-B02
A-27
XDM Accessories
The rod itself, which is inserted through the front rack rail into the clamp.
Plastic drum, needed only when the rod is used to route fibers. The drum,
which fits snugly over the rod, must be inserted over the rod before its rear
end is inserted into the clamp.
The following figure shows how to use the rod with fibers.
A-28
417006-2304-0H3-B02
XDM Accessories
The following figure shows how to use the rod with cables (in this case, the
plastic drum is not used and may be discarded).
Standard ODF
When there are a large number of optical fibers connected to an XDM,
additional connection arrangements may be required.
ECI recommends using an ODF installed in the XDM racks to terminate the
external fibers with the proper optical connectors.
The ODF provides a flexible and reliable solution for interfacing between
outside plant optical fiber cables and fiber optical terminal equipment. It is
designed to handle termination, splicing, and storage for excess length of
pigtails and patch cords.
417006-2304-0H3-B02
A-29
XDM Accessories
The unit is 1U high, and can be installed in ETSI A racks, as well as in 19"
racks using its configurable rack mounting brackets. An additional set of
brackets supplied with the installation kit enables installation in 23 in. 7 ft. bay
racks. The ODF is available with 12 or 24 ports, and SC, FC, or LC connectors.
All fiber connections are made on a swing-out tray that opens to the right at 90
and houses the splicing trays, optical adapter panels, and the fiber support. Left
side tray opening is available per order. The swing-out tray enables quick and
easy access to all internal parts for connection or maintenance activities. The
fiber connections are protected by a front cover, which latches to the assembly
and prevents unintended disconnection of fibers.
Optical terminal fibers can enter the ODF from the right or left side and be
connected to the optical adapters from one side. Pigtails connect to the adapters
from the other side. Excess length of pigtails and patch cords are threaded on a
fiber support that maintains the minimum bend radius to prevent fiber breaks.
A durable and robust tube leads the external fibers cable to the swing-out tray
and protects them from breaks. The adapters are arranged on panels in groups
of four or two (depending on the total number of ports). A large space between
the adapters enables easy access to each individual fiber and quick
reconfiguration.
A-30
417006-2304-0H3-B02
XDM Accessories
ODF_HP
Overview
ODF_HP is an optical distribution frame for fibers carrying high-power optical
signals (Hazard Level 3B). A typical application for the ODF_HP is to handle
the connections to the line side of the OFA_R Raman amplifiers.
The ODF_HP is a 1U high unit, ready for installation in 19 in. racks. ECI also
offers adapter brackets for installation in ETSI racks.
The following figure shows a general view of an ODF_HP ready for
installation in rack.
For safety, all fiber connections are made within the ODF_HP on special fiber
trays behind a lockable front panel.
The ODF_HP can be ordered with 1 or 2 fiber trays.
A fiber tray has twelve 250 mm (10 in.) fiber pigtails, each one terminating in
an E2000HP connector. The free ends of the pigtails are ready for splicing.
Therefore, ODF_HP has a capacity of up to 24 fibers in the 1U rack space.
417006-2304-0H3-B02
A-31
XDM Accessories
Physical description
The following figure shows a general view of a typical ODF_HP with its front
panel open, and identifies the various components.
After the panel is opened, it is possible to slide out the internal fiber trays (the
previous figure shows the top tray in the fully retracted position). Fibers enter
the ODF_HP through a wide opening located on the right-hand side, and
connect to the connectors located on the fiber tray. Make sure the protective
caps are installed on the connectors at all times until fibers are connected to
them.
The connectors are terminated in pigtails stored within the tray (see detail in
the following figure). The other set of fibers, usually formed in a harness, enter
the ODF_HP through an opening on the left-hand side, and are spliced to the
pigtails. The tray has a support comb for splices.
For convenience, the fibers can be identified on the labels located on the lid of
the fiber tray.
A-32
417006-2304-0H3-B02
XDM Accessories
Figure A-30: Typical 84-channel DDF unit for balanced E1 interfaces general view
417006-2304-0H3-B02
A-33
XDM Accessories
The 2U high DDF has a capacity of 14 E1 lines; the 4U high unit has a capacity
of 28 E1 lines. Each DDF can be ordered with BNC, BT43, or DIN 1.6/5.6 mm
connectors. The DDF has internal balanced/unbalanced (120 /75 )
impedance converters, and therefore allows connecting user's equipment with
unbalanced interfaces to the balanced interfaces of M2_84 electrical interface
modules. U links terminated in the appropriate connectors (BNC, BT43, or
DIN 1.6/5.6 mm) can be used to connect directly between the corresponding
sets of connectors. U links with monitoring connectors can also be ordered.
A-34
417006-2304-0H3-B02
XDM Accessories
Figure A-33: Typical 84-channel patch panel for balanced E1 interfaces general
views
417006-2304-0H3-B02
A-35
XDM Accessories
The E1 cables routed within the rack to E1 tributary modules, for example,
to the connectors located on the M2_84 panels, are connected to six 68-pin
SCSI female connectors. Each connector supports 14 E1 interfaces. The
tributaries supported by each connector are marked near each connector:
1-14, 15-28, 29-42, 43-56, 57-70, and 71-84.
A-36
417006-2304-0H3-B02
B
Connector Pin Assignments
In this appendix:
Overview ........................................................................................................ B-1
Platform Connectors ....................................................................................... B-2
xECB Connectors ........................................................................................... B-5
MECP Connectors ........................................................................................ B-10
ACP Connectors ........................................................................................... B-11
M2_84 Interface Module Connection Data .................................................. B-12
Alarms Handling Principles.......................................................................... B-19
xRAP-D Connectors ..................................................................................... B-21
xRAP-HP Connectors ................................................................................... B-28
xRAP-100 Connectors .................................................................................. B-34
miniRAP Connectors .................................................................................... B-40
Overview
This appendix provides connection data for user connectors located in XDM
platforms and associated ancillary equipment supplied by ECI. Optical and
coaxial connectors are described in the XDM-1000 Product Line Reference
Manual.
Any connectors not described in this appendix are reserved for use by ECI's
technical support personnel and/or for future expansion, and therefore no user
equipment may be connected to them.
417006-2304-0H3-B02
B-1
Platform Connectors
This section presents information on the platform connectors. See other
sections for information on connectors of the various cards and modules.
B-2
417006-2304-0H3-B02
ALARMS Connector
This connector is a 50-pin D-type male connector that carries two groups of
lines:
Eight platform alarm output lines referenced to the platform ground. Each
output is provided by the open collector of an optocoupler, and its active
state is the low logic level.
Designation
Function
Pin
Designation
Function
Direction
ALM_OP1
Direction
34
ALM_IP1
Alarm input 1
Input
GND
Ground
35
GND
Ground
ALM_OP2
36
ALM_IP2
Alarm input 2
Input
GND
Ground
37
GND
Ground
ALM_OP3
38
ALM_IP3
Alarm input 3
Input
GND
Ground
39
GND
Ground
ALM_OP4
40
ALM_IP4
Alarm input 4
Input
GND
Ground
41
GND
Ground
ALM_OP5
42
ALM_IP5
Alarm input 5
Input
10
GND
Ground
43
GND
Ground
11
ALM_OP6
44
ALM_IP6
Alarm input 6
Input
12
GND
Ground
45
GND
Ground
13
ALM_OP7
46
ALM_IP7
Alarm input 7
Input
14
GND
Ground
47
GND
Ground
15
ALM_OP8
48
ALM_IP8
Alarm input 8
Input
16
GND
Ground
49
GND
Ground
17-33
Not connected
50
Not connected
417006-2304-0H3-B02
B-3
xRAP Connector
The xRAP connector is a 9-pin D-type female connector that carries the
platform alarm outputs and a buzzer control line. All the outputs are referenced
to a common line, which is floating relative to the chassis ground.
This connector is intended for connection to one of the xRAP connectors.
The following figure identifies the connector pins as seen when looking into
the connector. The following table lists the pin assignment for the xRAP
connector.
B-4
Pin
Designation
Function
Direction
Critical
Critical alarm
Output
Not connected
Major
Major alarm
Output
Not connected
Minor
Minor alarm
Output
Common
Warning
Warning
Output
Not connected
Buzzer
Output
417006-2304-0H3-B02
xECB Connectors
This section provides information on the connectors located on the xECB
panels.
F-CHANNEL Connector
The F-CHANNEL connector is a 9-pin D-type male connector that provides a
serial RS-232 communication channel supporting the SLIP protocol. This
connector is intended for connection to an LCT-XDM service terminal. The
connection is made using a crossed cable to one of the serial RS-232 ports of
the PC serving as an LCT-XDM terminal.
The following figure identifies the connector pins as seen when looking into
the connector. The following table lists the connector pin assignment, together
with the corresponding pin in the LCT-XDM serial RS-232 port (assuming that
this port uses a 9-pin connector).
Name
Function
Direction
Not connected
Not connected
COM-F-RX
F-channel receive
Input
COM-F-TX
F-channel transmit
Output
Not connected
Not connected
GND
Ground
Pin 5 (ground)
6, 7,
8, 9
Not connected
Not connected
417006-2304-0H3-B02
B-5
The MAIN connector serves the main TMU, and the PROTECT connector
serves the standby (protection) TMU. These connectors are intended for
connection to the site timing reference distribution subsystem.
The following figure identifies the connector pins as seen when looking into
the connector. The following table lists their pin assignment.
B-6
Pin
Name
Function
Direction
SHIELD
Shield
CK_2M_MIL
Input
SHIELD
Shield
CK_2M_MOL
Output
Not connected
CK_2M_MIH
Input
SHIELD
Shield
CK_2M_MOH
Output
Not connected
417006-2304-0H3-B02
OW Connector
The OW connector is an RJ-11 connector that provides access to the 4W
analog interface to the platform's engineering orderwire facility. The analog
signals are digitized using standard 64 kbps PCM for transmission in the SDH
overhead (bytes E1 and E2, as configured by the management station).
This connector enables the connection of a standard handset or other voice
frequency equipment serving the OW.
The following figure identifies the connector pins. The following table lists the
pin assignment for the OW connector.
Name
Function
Direction
OW_TX1
Output
OW_TX2
Output
OW_RX1
Input
Not connected
OW_RX2
Input
Not connected
417006-2304-0H3-B02
B-7
OHA Connector
The OHA connector is a 50-pin D-type male connector with the following
hardware interfaces:
Two data channels with V.11 interface operating at rates up to 768 kbps
(software configurable). These channels are intended to provide access to
the auxiliary DCC bytes in the SDH overhead, and therefore provide a clear
transmission path for user payload, for example, for carrying traffic of
management stations using proprietary protocols.
The following figure identifies the connector pins as seen when looking into
the connector. The following table lists the pin assignment for the OHA
connector.
NOTE: Current XDM software versions do not support any
of the protocols of the OHA connector. This section is for
informative purposes only.
B-8
Pin
Name
Function
Direction
OHA-GRP1
Input
OHA-GTN1
Output
GND
Ground
OHA-VTA1
Output
OHA-VTB1
Output
OHA-VIA1
Output
OHA-VTA2
Output
OHA-VTB2
Output
OHA-VIA2
Output
10
OHA-VDA2
Output
11-17
18
OHA-GRP1
Input
19
OHA-GRN1
Input
20
OHA-GRN2
Input
417006-2304-0H3-B02
Pin
Name
Function
Direction
21
OHA-VRA1
Input
22
OHA-VRB1
Input
23
OHA-VIB1
Output
24
OHA-VRA2
Input
25
OHA-VRB2
Input
26
OHA-VIB2
Output
27
OHA-VDB2
Output
28-33
34
OHA-GTP2
Output
35
OHA-GTN2
Output
36
OHA-GRP2
Input
37
OHA-VCA1
Input
38
OHA-VCB1
Input
39
OHA-VDA1
Output
40
OHA-VDB1
Output
41
OHA-VCA2
Input
42
OHA-VCB2
Input
43-46
47
SHIELD
Shield
48-50
417006-2304-0H3-B02
B-9
MECP Connectors
This section provides information on the connectors located on the MECP
panels.
Ethernet Connectors
The two ETHERNET connectors on the MECP panel, designated MNG MAIN
and MNG PROT, are 8-pin RJ-45 connectors that provide two Ethernet
10BaseT management interfaces (one for each xMCP card installed in the
XDM platform). At any time, only the interface connected to the xMCP card
serving as the current main card is active; the interface connected to the xMCP
card serving as the protection card is in standby to provide protection for the
out-of-band management traffic.
Each ETHERNET connector is wired as a station port for direct connection
through a straight cable to a port of a 10BaseT Ethernet hub.
The following figure identifies the connector pins as seen when looking into
the connector.
The following table lists the pin assignment for a typical connector.
Table B-7: ETHERNET connector pin assignment
B-10
Pin
Designation
Function
Direction
TX+
Transmit + wire
Output
TX-
Transmit - wire
Output
RX+
Receive + wire
Input
4, 5
N/C
Not connected
RX-
Receive - wire
FGND
Frame ground
N/C
Not connected
Input
417006-2304-0H3-B02
ACP Connectors
The Ethernet connectors on the ACP card are 10-pin RJ-45 connectors.
The following figure identifies the connector pins as seen when looking into
the connector.
The following table lists the pin assignment for a typical connector.
Table B-8: ACP900 Ethernet connector pin assignments
Pin
Designation
Function
Direction
RX+
Receive + wire
Input
RX-
Receive - wire
Input
3, 4
VCC
Power 3.3 V
TX+
Transmit + wire
Output
TX-
Transmit - wire
Output
LED_RA
Indicator light
LED_RC
Indicator light
LED_LA
Indicator light
10
LED_LC
Indicator light
417006-2304-0H3-B02
B-11
The following table lists the pin assignment for a typical connector (for
unbalanced interfaces, wire A is the center (tip) conductor, and wire B is the
shield or ring). The table also lists the color of the wire connected to the
corresponding pin in the cables offered by ECI for connecting between the
tributary connector and a distribution frame.
The tributary numbers appearing in the table are given for the 1-14 connector.
To obtain the correct tributary numbers for other connectors, interpret the
numbers as representing the number of the tributary in its group (for example,
in connector 43-56, 6 represents E1 tributary 48).
Table B-9: M2_84B interface module, 14-tributary connector pin assignment
B-12
Pin
Name
Function
Direction
Wire color
RX1-A
Input
Brown
RX1-B
Input
Brown/gray ring
TX2-A
Output
Red
TX2-B
Output
Red/gray ring
GND
Shield
Light-gray/yellow ring
TX3-A
Output
Orange
TX3-B
Output
Orange/gray ring
RX4-A
Input
Yellow
RX4-B
Input
Yellow/gray ring
10
GND
Shield
White/yellow ring
11
RX5-A
Input
Green
12
RX5-B
Input
Green/gray ring
13
TXG-A
Output
Blue
417006-2304-0H3-B02
Pin
Name
Function
Direction
Wire color
14
TXG-B
Output
Blue/gray ring
15
GND
Shield
Brown/blue ring
16
TX7-A
Output
Violet
17
TX7-B
Output
Violet/gray ring
18
RX8-A
Input
White
19
RX8-B
Input
White/gray ring
20
GND
Shield
Red/blue ring
21
RX9-A
Input
Pink
22
RX9-B
Input
Pink/gray ring
23
TX10-A
Output
Brown/white ring
24
TX10-B
Output
Red/white ring
25
Not connected
26
TX11-A
Output
Orange/white ring
27
TX11-B
Output
Yellow/white ring
28
RX12-A
Input
Green/white ring
29
RX12-B
Input
Blue/white ring
30
Not connected
31
RX13-A
Input
Violet/white ring
32
RX13-B
Input
Light-gray/white ring
33
TX14-A
Output
Red/brown ring
34
TX14-B
Output
Yellow/brown ring
35
TX1-A
Output
Orange/brown ring
36
TX1-B
Output
Green/brown ring
37
RX2-A
Input
Blue/brown ring
38
RX2-B
Input
Violet/brown ring
39
Not connected
40
RX3-A
Input
Light-gray/brown ring
41
RX3-B
Input
Pink/brown ring
42
TX4-A
Output
Brown/red ring
43
TX4-B
Output
Light-gray/red ring
44
Not connected
45
TX5-A
Output
Yellow/red ring
46
TX5-B
Output
Green/red ring
47
RX6-A
Input
Blue/red ring
48
RX6-B
Input
Violet/red ring
49
Not connected
50
RX7-A
Input
White/red ring
51
RX7-B
Input
Pink/red ring
52
TX8A
Output
Brown/green ring
417006-2304-0H3-B02
B-13
Pin
Name
Function
Direction
Wire color
53
TX8-B
Output
Light-gray/green ring
54
Not connected
55
TX9A
Output
Yellow/green ring
56
TX9-B
Output
Orange/green ring
57
RX10-A
Input
Violet/green ring
58
RX10-B
Input
Blue/green ring
59
Not connected
60
RX11-A
Input
Pink/green ring
61
RX11-B
Input
White/green ring
62
TX12A
Output
Brown/yellow ring
63
TX12-B
Output
Red/yellow ring
64
Not connected
65
TX13A
Output
Orange/yellow ring
66
TX13-B
Output
Green/yellow ring
67
RX14-A
Input
Blue/yellow ring
68
RX14-B
Input
Violet/yellow ring
B-14
417006-2304-0H3-B02
The following table lists the patch panel wiring, that is, the connections
between the 68-pin SCSI connectors and the 25-pin D-type connectors.
Table B-10: Patch panel wiring
SCSI pin
Name
Function
Direction
D-type pin
RX1-A
Receive, tributary 1,
wire A
Input
IN/an (1-7)
Pin 2
RX1-B
Receive, tributary 1,
wire B
Input
IN/an (1-7)
Pin 1
TX2-A
Transmit, tributary 2,
wire A
Output
OUT/ab (1-7)
Pin 16
TX2-B
Transmit, tributary 2,
wire B
Output
OUT/ab (1-7)
Pin 15
GND
Shield
OUT/ab (8-14)
Pin 13
TX3-A
Transmit, tributary 3,
wire A
Output
OUT/ab (1-7)
Pin 5
TX3-B
Transmit, tributary 3,
wire B
Output
OUT/ab (1-7)
Pin 4
RX4-A
Receive, tributary 4,
wire A
Input
IN/an (1-7)
Pin 19
RX4-B
Receive, tributary 4,
wire B
Input
IN/an (1-7)
Pin 18
10
GND
Shield
IN/an (8-14)
Pin 13
11
RX5-A
Receive, tributary 5,
wire A
Input
IN/an (1-7)
Pin 8
12
RX5-B
Receive, tributary 5,
wire B
Input
IN/an (1-7)
Pin 7
13
TXG-A
Transmit, tributary 6,
wire A
Output
OUT/ab (1-7)
Pin 22
14
TXG-B
Transmit, tributary 6,
wire B
Output
OUT/ab (1-7)
Pin 21
15
GND
Shield
OUT/ab (1-7)
Pins 3, 6, 9,
13, 14, 17, 20,
23
16
TX7-A
Transmit, tributary 7,
wire A
Output
OUT/ab (1-7)
Pin 11
17
TX7-B
Transmit, tributary 7,
wire B
Output
OUT/ab (1-7)
Pin 10
18
RX8-A
Receive, tributary 8,
wire A
Input
IN/an (8-14)
Pin 2
19
RX8-B
Receive, tributary 8,
wire B
Input
IN/an (8-14)
Pin 1
417006-2304-0H3-B02
B-15
B-16
SCSI pin
Name
Function
Direction
D-type pin
20
GND
Shield
IN/an (1-7)
Pins 3, 6, 9,
13, 14, 17, 20,
23
21
RX9-A
Receive, tributary 9,
wire A
Input
IN/an (8-14)
Pin 16
22
RX9-B
Receive, tributary 9,
wire B
Input
IN/an (8-14)
Pin 15
23
TX10-A
Output
OUT/ab (8-14)
Pin 5
24
TX10-B
Output
OUT/ab (8-14)
Pin 4
25
Not connected
26
TX11-A
Output
OUT/ab (8-14)
Pin 19
27
TX11-B
Output
OUT/ab (8-14)
Pin 18
28
Input
IN/an (8-14)
Pin 8
29
RX12-B
Input
IN/an (8-14)
Pin 7
30
Not connected
31
Input
IN/an (8-14)
Pin 22
32
RX13-B
Input
IN/an (8-14)
Pin 21
33
TX14-A
Output
OUT/ab (8-14)
Pin 11
34
TX14-B
Output
OUT/ab (8-14)
Pin 10
35
TX1-A
Transmit pair,
tributary 1, wire A
Output
OUT/ab (1-7)
Pin 2
36
TX1-B
Transmit, tributary 1,
wire B
Output
OUT/ab (1-7)
Pin 1
37
RX2-A
Receive, tributary 2,
wire A
Input
IN/an (1-7)
Pin 16
38
RX2-B
Receive, tributary 2,
wire B
Input
IN/an (1-7)
Pin 15
39
Not connected
40
RX3-A
Receive, tributary 3,
wire A
Input
IN/an (1-7)
Pin 5
41
RX3-B
Receive, tributary 3,
wire B
Input
IN/an (1-7)
Pin 4
417006-2304-0H3-B02
SCSI pin
Name
Function
Direction
D-type pin
42
TX4-A
Transmit, tributary 4,
wire A
Output
OUT/ab (1-7)
Pin 19
43
TX4-B
Transmit, tributary 4,
wire B
Output
OUT/ab (1-7)
Pin 18
44
Not connected
45
TX5-A
Transmit, tributary 5,
wire A
Output
OUT/ab (1-7)
Pin 8
46
TX5-B
Transmit, tributary 5,
wire B
Output
OUT/ab (1-7)
Pin 7
47
RX6-A
Receive, tributary 6,
wire A
Input
IN/an (1-7)
Pin 22
48
RX6-B
Receive, tributary 6,
wire B
Input
IN/an (1-7)
Pin 21
49
Not connected
50
RX7-A
Receive, tributary 7,
wire A
Input
IN/an (1-7)
Pin 11
51
RX7-B
Receive, tributary 7,
wire B
Input
IN/an (1-7)
Pin 10
52
TX8A
Transmit, tributary 8,
wire A
Output
OUT/ab (8-14)
Pin 2
53
TX8-B
Transmit, tributary 8,
wire B
Output
OUT/ab (8-14)
Pin 1
54
Not connected
55
TX9A
Transmit, tributary 9,
wire A
Output
OUT/ab (8-14)
Pin 16
56
TX9-B
Transmit, tributary 9,
wire B
Output
OUT/ab (8-14)
Pin 15
57
Input
IN/an (1-7)
Pin 5
58
RX10-B
Input
IN/an (1-7)
Pin 4
59
Not connected
60
Input
IN/an (8-14)
Pin 19
61
RX11-B
Input
IN/an (8-14)
Pin 18
62
TX12A
Output
OUT/ab (8-14)
Pin 8
63
TX12-B
Output
OUT/ab (8-14)
Pin 7
64
Not connected
417006-2304-0H3-B02
B-17
SCSI pin
Name
Function
Direction
D-type pin
65
TX13A
Output
OUT/ab (8-14)
Pin 22
66
TX13-B
Output
OUT/ab (8-14)
Pin 21
67
Input
IN/an (8-14)
Pin 11
68
RX14-B
Input
IN/an (8-14)
Pin 10
B-18
417006-2304-0H3-B02
Alarm Input
Alarm input is implemented by an optocoupler circuit shown in the following
figure.
When an alarm is detected at the client side, it provides a closed dry contact at
the input (between the optocoupler's LED and ground), causing the LED to
conduct and light. The light activates the optocoupler's transistor output stage,
resulting in a low logic level at the collector. The output signal connected to the
XDM processor is handled as an input alarm.
The client's dry contact ratings are 12 V in open state, and 0.5A in closed state.
417006-2304-0H3-B02
B-19
Alarm Output
Alarm output is implemented by a change-over dry contact circuit shown in the
following figure.
When an alarm is detected in the XDM, the processor sends a low logic level to
the relay, activating it. The state of the dry contact connected to the client side
changes and provides an alarm output signal to client's facility.
The relay contact ratings are 57.6 V in open state, and 1A in closed state.
B-20
417006-2304-0H3-B02
xRAP-D Connectors
This section provides information on the connectors located on the xRAP-D
unit.
Figure B-14: xRAP-D and xRAP-B shelf DC input power connector pin functions
417006-2304-0H3-B02
B-21
B-22
Pin
Name
Function
Direction
N/C
Not connected
--
ALM_IP1
Input
ALM_IN1
Input
ALM_IP2
Input
ALM_IN2
Input
ALM_IP3
Input
ALM_IN3
Input
ALM_IP4
Input
ALM_IN4
Input
10
ALM_O4
Alarm output 4
Output
11
N/C
Not connected
--
12
GND
Ground
--
13
ALM_O1
Alarm output 1
Output
14
N/C
Not connected
--
15
GND
Ground
--
16
ALM_O2
Alarm output 2
Output
17
N/C
Not connected
--
18
BUZZ
Buzzer
Input
19
N/C
Not connected
--
20
GND
Ground
--
21
CRIT_COM
Critical alarm
Output
22
N/C
Not connected
--
23
MAJ_COM
Major alarm
Output
24
GND
Ground
--
25
N/C
Not connected
--
26
GND
Ground
--
27
MIN_COM
Minor alarm
Output
28
N/C
Not connected
--
29
WARN_COM
Warning alarm
Output
30
GND
Ground
--
31
ALM_O3
Alarm output 3
Output
32
GND
Ground
--
33
N/C
Not connected
--
34
N/C
Not connected
--
35
GND
Ground
--
36
N/C
Not connected
--
417006-2304-0H3-B02
ALARMS Connector
The ALARMS connector is a SCSI 68-pin female connector that carries the
following groups of lines to the customer equipment:
Eight external alarm inputs connected to the ALARM inputs of the XDM500 platforms. Four inputs are allocated to each XDM-500 platform. Each
input is activated by closing a dry contact provided from the customers
facility.
Eight sets of change-over relay contacts (four per platform) floating with
respect to platform ground, which serve as rack (bay) alarm indication
lines. The relays, identified as critical, major, minor, and warning, are
activated by the corresponding alarm relays of XDM-500 platforms.
Two lines for muting the Critical buzzer in the customer's alarms collecting
system.
417006-2304-0H3-B02
B-23
B-24
Assignment
Pin
Designation
Function
Shelf 2
CRIT_NC
Black
CRIT_COM
Brown
CRIT_NO
Red
MAJ_NC
Output
Orange
MAJ_COM
Output
Yellow
MAJ_NO
Output
Green
MIN_NC
Output
Blue
MIN_COM
Output
Violet
MIN_NO
Output
Gray
10
WARN_NC
Warning alarm
relay, normally
closed contact
Output
White
11
WARN_COM
Warning alarm
relay, common
contact
Output
Pink
12
WARN_NO
Warning alarm
Output
relay, normally open
contact
Light green
13
BUZZ_NC
Buzzer relay,
normally closed
contact
Output
Black/white
14
BUZZ_COM
Buzzer relay,
common contact
Output
Brown/
white
15
BUZZ_NO
Buzzer relay,
normally open
contact
Output
Red/white
16
ALMO1_NC
Output relay 1,
normally closed
contact
Output
Orange/
white
17
ALMO1_COM
Output relay 1,
common contact
Output
Green/
white
Direction
Wire color
417006-2304-0H3-B02
417006-2304-0H3-B02
Pin
Designation
Function
Direction
Wire color
18
ALMO1_NO
Output relay 1,
normally open
contact
Output
Blue/white
19
ALMO2_NC
Output relay 2,
normally closed
contact
Output
Violet/
white
20
ALMO2_COM
Output relay 2,
common contact
Output
Red/black
21
ALMO2_NO
Output relay 2,
normally open
contact
Output
Orange/
black
22
ALMO3_NC
Output relay 3,
normally closed
contact
Output
Yellow/
black
23
ALMO3_COM
Output relay 3,
common contact
Output
Green/
black
24
ALMO3_NO
Output relay 3,
normally open
contact
Output
Gray/black
25
ALMO4_NC
Output relay 4,
normally closed
contact
Output
Pink/black
26
ALMO4_COM
Output relay 4,
common contact
Output
Pink/green
27
ALMO4_NO
Output relay 4,
normally open
contact
Output
Pink/red
28
ALMIN_1
Pink/violet
29
ALMIN_2
Light blue
30
GND
ground
Light
blue/brown
31
ALMIN_3
Light blue/red
32
ALMIN_4
Light
blue/violet
33
GND
ground
Light
blue/black
34
BUZZ_OFF
Buzzer mute
Output
Gray/green
B-25
B-26
Assignment
Pin
Designation
Function
Shelf 1
35
CRIT_NC
Gray/red
36
CRIT_COM
Gray/violet
37
CRIT_NO
Light
green/black
38
MAJ_NC
Output
Violet/black
39
MAJ_COM
Output
Black/white
dots
40
MAJ_NO
Output
Brown/
white dots
41
MIN_NC
Output
Red/white
dots
42
MIN_COM
Output
Orange/
white dots
43
MIN_NO
Output
Green/
white dots
44
WARN_NC
Warning alarm
relay, normally
closed contact
Output
Blue/white
dots
45
WARN_COM
Warning alarm
relay, common
contact
Output
Violet/
white dots
46
WARN_NO
Warning alarm
Output
relay, normally open
contact
White/
black dots
47
BUZZ_NC
Buzzer relay,
normally closed
contact
Output
Yellow/
black dots
48
BUZZ_COM
Buzzer relay,
common contact
Output
Green/
black dots
49
BUZZ_NO
Buzzer relay,
normally open
contact
Output
Light blue/
black dots
50
ALMO1_NC
Output relay 1,
normally closed
contact
Output
Pink/black
dots
51
ALMO1_COM
Output relay 1,
common contact
Output
Red/black
dots
52
ALMO1_NO
Output relay 1,
normally open
contact
Output
Orange/
black dots
Direction
Wire color
417006-2304-0H3-B02
417006-2304-0H3-B02
Pin
Designation
Function
Direction
Wire color
53
ALMO2_NC
Output relay 2,
normally closed
contact
Output
Violet/black
dots
54
ALMO2_COM
Output relay 2,
common contact
Output
Gray/black
dots
55
ALMO2_NO
Output relay 2,
normally open
contact
Output
Orange/red
dots
56
ALMO3_NC
Output relay 3,
normally closed
contact
Output
Yellow/red
dots
57
ALMO3_COM
Output relay 3,
common contact
Output
Green/red
dots
58
ALMO3_NO
Output relay 3,
normally open
contact
Output
Blue/red dots
59
ALMO4_NC
Output relay 4,
normally closed
contact
Output
Violet/red
dots
60
ALMO4_COM
Output relay 4,
common contact
Output
Gray/red dots
61
ALMO4_NO
Output relay 4,
normally open
contact
Output
White/red
dots
62
ALMIN_1
Pink/red dots
63
ALMIN_2
Yellow/
white
64
GND
ground
Gray/white
65
ALMIN_3
Pink/white
66
ALMIN_4
Brown/
black
67
GND
ground
Blue/black
68
BUZZ_OFF
Buzzer mute
Output
Gray/white
dots
B-27
xRAP-HP Connectors
This section provides information on the connectors located on the xRAP-HP
units.
The following table lists the pin assignment for this connector.
Table B-13: SHELF EXTERNAL ALARM/CONTROL connector pin assignment
B-28
Pin
Designation
Function
Direction
ALM_IP1
Output
ALM_IP2
Output
ALM_IP3
Output
ALM_IP4
Output
ALM_IP5
Output
ALM_IP6
Output
ALM_IP7
Output
ALM_IP8
Output
Not connected
10
GND
Ground
11-13
Not connected
14
ALM_OP1
15
ALM_OP2
Input
16
ALM_OP3
Input
17
ALM_OP4
Input
18
ALM_OP5
Input
19
ALM_OP6
Input
20
ALM_OP7
Input
417006-2304-0H3-B02
Pin
Designation
Function
Direction
21
ALM_OP8
Input
22
Not connected
23
GND
Ground
Not connected
24, 25 -
Line function
XDM side
34
36
38
40
42
44
46
48
Not connected
10
Ground
11-13
Not connected
14
15
16
17
18
19
11
20
13
21
15
22
Not connected
23
Ground
24, 25
Not connected
417006-2304-0H3-B02
B-29
RAP Connectors
The three RAP connectors are 9-pin D-type female connectors. Each of these
connectors is intended to be connected to an xRAP connector (page B-4) that
carries the alarm relay outputs and buzzer control line of the platform.
The following figure identifies the connector pins as seen when looking into
the connector.
The following table lists the pin assignment for the RAP connector.
Table B-15: RAP connector pin assignments
Pin
Designation
Function
Direction
Critical
Input
Major
Input
Minor
Input
Warning
Warning relay
Input
Buzzer
Input
6-8
Not connected
Common
The connection between each RAP connector and the corresponding XDM
platform connector is performed by means of a cable terminated in a 9-pin
D-type female connector at the xRAP-HP side, and a 9-pin D-type male
connector at the XDM platform side. Cable wiring is listed in the following
table.
Table B-16: RAP shelf cable wiring diagram
B-30
xRAP-HP side
Function
XDM side
Warning indication
6, 7, 8
Not connected
2, 4, 8
417006-2304-0H3-B02
Relay contact ratings are 57.6 V in open state, and 1A in closed state.
The following figure identifies the CONTROL CONNECTION connector pins
as seen when looking into the connector.
The following table lists the pin assignment for the CONTROL
CONNECTION connector. The table also lists the color of the wire connected
to the corresponding pin in the cables offered by ECI for connecting between
the CONTROL CONNECTION connector and a distribution frame.
Table B-17: CONTROL CONNECTION connector pin assignment
Pin
Designation
Function
Direction
Wire color
ALARM_IN1
Input
Brown
ALARM_IN4
Input
Brown/gray-ring
ALARM_IN7
Input
Red
Not used
Red/gray-ring
OUT1_COM
Output
Orange
OUT2_COM
Output
Orange/gray-ring
OUT3_COM
Output
Yellow
OUT4_COM
Output
Yellow/gray-ring
417006-2304-0H3-B02
B-31
B-32
Pin
Designation
Function
Direction
Wire color
OUT5_COM
Output
Green
10
OUT6_COM
Output
Green/gray-ring
11
OUT7_COM
Output
Blue
12
OUT8_COM
Output
Blue/gray-ring
13
Not used
Violet
14
CRIT_COM
Output
Violet/gray-ring
15
MAJOR_COM
White
16
MINOR_COM
White/gray-ring
17
WARN_COM
Output
Pink
18
ALARM_IN2
Input
Pink/gray-ring
19
ALARM_IN5
Input
Brown/white-ring
20
ALARM_IN8
Input
Red/white-ring
21
Not used
Orange/white-ring
22
OUT1NO
Output
Yellow/white-ring
23
OUT2NO
Output
Green/white-ring
24
OUT3NO
Output
Blue/white-ring
25
OUT4NO
Output
Violet/white-ring
26
OUT5NO
Output
Light-gray/white-rin
g
27
OUT6NO
Output
Red/brown-ring
28
OUT7NO
Output
Yellow/brown-ring
29
OUT8NO
Output
Orange/brown-ring
30
CRIT_NC
Output
Green/brown-ring
31
MAJOR_NC
Output
Blue/brown-ring
417006-2304-0H3-B02
Pin
Designation
Function
Direction
Wire color
32
MINOR_NC
Output
Violet/brown-ring
33
WARN_NC
Output
Light-gray/brown-ri
ng
34
ALARM_IN3
Input
Pink/brown-ring
35
ALARM_IN6
Input
Brown/red-ring
36
GNDPS
Ground
Light-gray/red-ring
37
Not used
Yellow/red-ring
38
OUT1NC
Output
Green/red-ring
39
OUT2NC
Output
Blue/red-ring
40
OUT3NC
Output
Violet/red-ring
41
OUT4NC
Output
White/red-ring
42
OUT5NC
Output
Pink/red-ring
43
OUT6NC
Output
Brown/green-ring
44
OUT7NC
Output
Light-gray/green-rin
g
45
OUT8NC
Output
Yellow/green-ring
46
Not used
Orange/green-ring
47
CRIT_NO
Output
Violet/green-ring
48
MAJOR_NO
Output
Blue/green-ring
49
MINOR_NO
Output
Brown/blue-ring
50
WARN_NO
Output
Red/blue-ring
417006-2304-0H3-B02
B-33
xRAP-100 Connectors
This section provides information on the connectors located on the xRAP-100
units.
B-34
417006-2304-0H3-B02
The following table lists the pin assignment for this connector.
Table B-18: xRAP-100 SHELF ALARM connector pin assignment
Pin
Name
Function
Direction
N/C
--
--
ALM_IP1
Input
ALM_IN1
Input
ALM_IP2
Input
ALM_IN2
Input
ALM_IP3
Input
ALM_IN3
Input
ALM_IP4
Input
ALM_IN4
Input
10
N/C
--
--
11
N/C
--
--
12
GND
Ground
--
13
ALM_O1
Output
14
N/C
--
--
15
GND
Ground
--
16
ALM_O2
Output
17
N/C
--
--
18
BUZ_COM
Buzzer common
Input
19
N/C
--
--
20
GND
Ground
--
21
CRIT_COM
--
22
N/C
--
--
23
MAJ_COM
Input
417006-2304-0H3-B02
B-35
Pin
Name
Function
Direction
24
GND
Ground
--
25
N/C
--
--
26
GND
Ground
--
27
MIN_COM
Input
28
N/C
--
--
29
WARN_COM
--
30
GND
Ground
--
31
N/C
--
--
32
N/C
--
--
33
N/C
--
--
34
N/C
--
--
35
GND
Ground
--
36
N/C
--
--
Sixteen external alarm inputs connected to the ALARM inputs of the XDM
shelves. Four inputs are allocated to each XDM platform. Each input is
activated by closing a dry contact provided from the customer's facility.
The following table lists the pin assignment for the ALARM IN/OUT
connector.
B-36
417006-2304-0H3-B02
Pin
Designation
Function
Shelf 1
ALM_01NO
Black
ALM_01COM
Output
Brown
ALM_01NC
Output
Red
ALM_02NO
Orange
ALM_02COM
Output
Yellow
ALM_02NC
Output
Green
ALM_03NO
Blue
ALM_03COM
Output
Violet
ALM_03NC
Output
Gray
10
ALM_04NO
White
11
ALM_04COM
Output
Pink
12
ALM_04NC
Output
Light Green
13
ALM_05NO
Black/White
14
ALM_05COM
Output
Brown/White
15
ALM_05NC
Output
Red/White
16
ALM_06NO
Orange/White
17
ALM_06COM
Output
Green/White
18
ALM_06NC
Output
Blue/White
19
ALM_07NO
Violet/White
20
ALM_07COM
Output
Red/Black
21
ALM_07NC
Output
Orange/Black
22
ALM_08NO
Yellow/Black
23
ALM_08COM
Output
Green/Black
24
ALM_08NC
Output
Gray/Black
Shelf 2
Shelf 3
Shelf 4
417006-2304-0H3-B02
Direction
Wire color
B-37
Assignment
Pin
Designation
Function
Direction
Wire color
All shelves
25
CRIT_NC
Output
Pink/Black
26
CRIT_NO
Output
Pink/Green
27
CRIT_COM
Output
Pink/Red
28
MAJ_NC
Output
Pink/Violet
29
MAJ_NO
Output
Light Blue
30
MAJ_COM
Output
Light Blue/Brown
31
MIN_NC
Output
Light Blue/Red
32
MIN_NO
Output
Light Blue/Violet
33
MIN_COM
Output
Light Blue/Black
34
WARN_COM
Output
Gray/Green
35
ALMIN1
Input
Gray/Red
36
ALM_IN1
Input
Gray/Violet
37
ALMIN2
Input
Light Green/Black
38
ALM_IN2
Input
Violet/Black
39
ALMIN3
Input
Black/White dots
40
ALM_IN3
Input
Brown/White dots
41
ALMIN4
Input
Red/White dots
42
ALM_IN4
Input
Orange/White dots
43
ALMIN5
Input
Green/White dots
44
ALM_IN5
Input
Blue/White dots
45
ALMIN6
Input
Violet/White dots
46
ALM_IN6
Input
White/Black dots
47
ALMIN7
Input
Yellow/Black dots
48
ALM_IN7
Input
Green/Black dots
49
ALMIN8
Input
50
ALM_IN8
Input
Pink/Black dots
Shelf 1
Shelf 2
B-38
417006-2304-0H3-B02
Assignment
Pin
Designation
Function
Direction
Wire color
Shelf 3
51
ALMIN9
Input
Red/Black dots
52
ALM_IN9
Input
Orange/Black dots
53
ALMIN10
Input
Violet/Black dots
54
ALM_IN10
Input
Gray/Black dots
55
ALMIN11
Input
56
ALM_IN11
Input
Orange/Red dots
57
ALMIN12
Input
Yellow/Red dots
58
ALM_IN12
Input
Green/Red dots
59
ALMIN13
Input
Violet/Red dots
60
ALM_IN13
Input
Gray/Red dots
61
ALMIN14
Input
White/Red dots
62
ALM_IN14
Input
Pink/Red dots
63
ALMIN15
Input
Yellow/White
64
ALM_IN15
Input
Gray/White
65
ALMIN16
Input
Pink/White
66
ALM_IN16
Input
Brown/Black
67
WARN_NC
Output
Blue/Black
68
WARN_NO
Output
Gray/White dots
Shelf 4
All shelves
417006-2304-0H3-B02
B-39
miniRAP Connectors
Shelf DC Input Power Connectors
The shelf DC input power connectors are 3-pin D-type female connectors. The
following figure identifies the functions of the shelf DC input connector pins,
as seen when looking into the connector.
SEVERITY IN Connector
The SEVERITY IN alarm connector is a 9-pin D-type female connector. It is
connected to the ALARMS connector of an XDM-500 shelf (see ALARMS
Connector (page B-3) for a detailed description). The following figure
identifies the connector pins, as seen when looking into the connector, and the
table lists its pin assignments.
B-40
Pin
Name
Function
Critical
Major
Minor
Warning
Buzzer
N/C
Not used
N/C
Not used
N/C
Not used
GND
Ground
417006-2304-0H3-B02
Name
Function
Critical_com
Critical_NO
Critical alarm NO
Major_NC
Major alarm NC
Major_com
Major_NO
Major alarm NO
Critical_NC
Critical alarm NC
Minor_NO
Minor alarm NO
Minor_com
Minor_NC
Minor alarm NC
417006-2304-0H3-B02
B-41
B-42
417006-2304-0H3-B02
C
Upgrades and Expansions
In this appendix:
Overview ........................................................................................................ C-1
16- to 32-Channel Mux/DeMux Expansion ................................................... C-2
Upgrading and Expanding Optical Networks ................................................. C-3
Matrix and SDH Data Card Upgrades ............................................................ C-7
Overview
Various upgrade and expansion options are always available, given the
modular, build-as-you-grow nature of the XDM product line. This includes
matrix upgrades, SDH data card upgrades, and optical component upgrades. A
few examples are provided in this section. For more information, contact the
ECI technical support team.
417006-2304-0H3-B02
C-1
417006-2304-0H3-B02
417006-2304-0H3-B02
C-3
Planning the optical network for the capacity required initially. This must
take into consideration the allocation of wavelengths necessary to meet the
initial traffic capacity requirements and the power budget for optical
amplifiers.
C-4
Number and type of XDM platforms and equipment racks needed for
the initial site capacity.
Number and type of XDM platforms and equipment racks needed for
the final (maximum) site capacity.
Planning and installing the full optical cabling for the final (maximum)
site capacity. This includes the fibers needed to carry the local
customer's signals to the ODFs, the fibers between the ODFs and the
transponders, and from the transponders to the optical support modules
(OADMs and DWDM modules).
Planning the site power and cooling requirements for the final
(maximum) site capacity.
417006-2304-0H3-B02
The site configurations for each expansion stage must be fully documented in
the network and site installation manuals, in accordance with the standard
procedures.
NOTE: ECI recommends documenting the installation details
Expansion Process
The actual expansion process is based on the preplanned expansion steps
described in the installation procedures. The following required activities are
listed in the order of execution.
To expand your system:
1. Insert additional transponder cards in the XDM platforms in accordance
with the installation procedures.
2. Perform a preliminary configuration of the transponders (slot assignment
definition and wavelength setting) using the LCT-XDM.
3. Use an OPM to measure optical output power (see "Measuring Optical
Levels" page 8-8).
NOTE: Record all the measurement results in the
commissioning document.
417006-2304-0H3-B02
C-5
Expansion Checklist
The following checklist is provided to help execute the expansion activities:
1. Check wavelength availability on the optical link.
2. Check that the link power budget does not exceed the specification of any
optical trail.
3. Check slot availability in the XDM platforms.
4. Check the installation records.
5. Check the required optical fibers:
C-6
417006-2304-0H3-B02
417006-2304-0H3-B02
C-7
C-8
417006-2304-0H3-B02
D
Integrating XDM
Equipment in SYNCOM
Networks
In this appendix:
Overview ........................................................................................................ D-1
Network Implementation Considerations ....................................................... D-2
Network Timing Considerations .................................................................... D-5
Network Management Considerations ........................................................... D-5
Recommended Integration Procedures ........................................................... D-8
Overview
This appendix provides recommendations and guidelines for integrating XDM
equipment in existing SYNCOM networks.
The information presented in this appendix assumes familiarity with the
technical characteristics and management capabilities of SYNCOM and XDM
equipment. Refer to the equipment management user manuals for additional
information and detailed management procedures.
417006-2304-0H3-B02
D-1
Network Implementation
Considerations
Existing SYNCOM networks can benefit from the addition of XDM equipment
in two ways:
D-2
417006-2304-0H3-B02
A link through the XDM network is not necessarily symmetrical, that is,
between endpoints at the same level. For example, an SYNCOM STM-4
endpoint can be connected through an ASF16 aggregate to an XDM
SIO16_XX or XIO card and dropped through an XDM SIO1&4_XX or XIO
STM-4 port.
417006-2304-0H3-B02
D-3
D-4
417006-2304-0H3-B02
Network Management
Considerations
An XDM network has its own management facilities, and therefore it can
always be managed independently of the SYNCOM network. However, any
existing SYNCOM network has a management infrastructure deployed with
significant investments in establishing the required facilities and procedures.
Therefore, when XDM equipment is integrated into the network, it is necessary
to integrate the XDM management functions as smoothly as possible into those
of the existing network.
Follow these main guidelines:
Prevent problems that may occur when the traffic flows through different
types of equipment.
417006-2304-0H3-B02
D-5
XDM NEs support the same basic types of management communication and in
addition has an optical supervisory channel (OSC) that uses a separate optical
carrier to carry the management channel through the fibers used to carry the
payload, without occupying wavelengths in the payload bands. Note, however,
that for XDM NEs, the type of DCC used for management (RS-DCC or
MS-DCC) is independently selected for each port.
Most SYNCOM networks use the DCC for management communication.
Therefore, when an XDM NE is integrated in an SYNCOM network, it must
also use the DCC for management communication. This is always possible,
provided the following conditions are met:
D-6
The XDM NE is configured to cross connect the DCC between the relevant
ports. Make sure to check the type of DCC used by the SYNCOM NE RS-DCC or MS-DCC.
417006-2304-0H3-B02
At any time, one of these stations serves as the primary station and actively
manages the NEs.
The other station, the mirror station, does not manage the NEs but is
continuously in session with the primary station. The primary station
updates the mirror station database to keep it synchronized with its
database.
Therefore, at any time only one station manages the network, but the other
station can take over immediately when the primary station or its management
communication links fail.
417006-2304-0H3-B02
D-7
The first issue is ensuring continuity of the DCC throughout the integrated
network (see "Flow of Management Traffic" page D-6).
Recommended Integration
Procedures
This section presents a checklist of the tasks needed for a smooth integration of
XDM equipment in SYNCOM networks.
Use this checklist to supplement the normal network planning activities.
1. Update the embedded software versions of the various equipment units as
follows:
417006-2304-0H3-B02
417006-2304-0H3-B02
D-9
D-10
417006-2304-0H3-B02
E
Slot Designation
Conversion Table
In this appendix:
Slot Designation Conversion Table .................................................................E-1
Actual slot
marking
PW1
101
13
304
PW2
102
14
305
M1
201
15
306
M2
202
16
307
M3
203
C1
308
M4
204
C2
309
M5
205
17
310
M6
206
18
311
M7
207
19
312
M8
208
110
313
M9
209
111
314
417006-2304-0H3-B02
E-1
Actual slot
marking
Actual slot
marking
M10
210
112
315
M11
211
X2
316
C0
300
F1
401
X1
301
F2
402
11
302
F3
403
12
303
E-2
PW1
101
PW2
102
X1
201
C1
202
C2
203
IC1
204
IC2
205
IC3
206
MC1
207
MC2
208
MC3
209
MC4
210
IC4
211
IC5
212
IC6
213
X2
214
C0
300
F1
301
F2
302
F3
303
417006-2304-0H3-B02
F
Standards and References
In this appendix:
Overview ......................................................................................................... F-1
Broadband Forum ............................................................................................ F-1
Environmental Standards ................................................................................. F-2
ETSI: European Telecommunications Standards Institute .............................. F-2
IEC: International Electrotechnical Commission ............................................ F-3
IEEE: Institute of Electrical and Electronic Engineers.................................... F-4
IETF: Internet Engineering Task Force ........................................................... F-5
ISO: International Organization for Standardization ....................................... F-7
ITU-T: International Telecommunication Union ............................................ F-7
MEF: Metro Ethernet Forum ......................................................................... F-12
NIST: National Institute of Standards and Technology................................. F-12
North American Standards ............................................................................ F-13
OMG: Object Management Group ................................................................ F-14
TMF: TeleManagement Forum ..................................................................... F-14
Web Protocol Standards ................................................................................ F-14
Overview
The following is a list of standards and reference documents that relate to the
XDM platform families. The standards are listed alphabetically by groups.
Broadband Forum
417006-2304-0H3-B02
F-1
Environmental Standards
ETSI: European
Telecommunications Standards
Institute
F-2
417006-2304-0H3-B02
IEC: International
Electrotechnical Commission
IEC 917: Modular Order for the Development of Mechanical Structures for
Electronic Equipment Practices.
417006-2304-0H3-B02
F-3
F-4
417006-2304-0H3-B02
RFC 2256: A Summary of the X.500(96) User Schema for use with
LDAPv3.
RFC 2474: Definition of the Differentiated Services Field (DS Field) in the
IPv4 and IPv6 Headers.
417006-2304-0H3-B02
F-5
F-6
417006-2304-0H3-B02
IETF Drafts:
draft-ietf-l2vpn-vpls-ldp.
draft-ietf-l2vpn-vpls-mcast-reqts.
draft-ietf-magma-snoop.
draft-ietf-mpls-rsvp-te-p2mp.
draft-ietf-mpls-tp-nm-framework.
draft-ietf-mpls-tp-nm-req.
draft-ietf-pwe3-ethernet-encap.
draft-martini-l2circuit-encap-mpls.
draft-sajassi-l2vpn-vpls-multicast-congruency.
draft-vasseur-mpls-backup-computation.
ITU-T: International
Telecommunication Union
417006-2304-0H3-B02
F-7
F-8
G.661: Definition and Test Methods for the Relevant Generic Parameters of
Optical Amplifier Devices and Subsystems.
G.691: Optical Interfaces for Single Channel SDH Systems with Optical
Amplifiers and STM-64 Systems (Draft).
G.704: Synchronous Frame Structures Used at 1544, 6312, 2048, 8448 and
44 736 kbps Hierarchical Levels.
G.775: Loss of Signal (LOS), Alarm Indication Signal (AIS) and Remote
Defect Indication (RDI) defect detection and clearance criteria for PDH
signals.
417006-2304-0H3-B02
G.823: The Control of Jitter and Wander within Digital Networks Based on
the 2048 kbit/s Hierarchy.
G.825: The Control of Jitter and Wander within Digital Networks Based on
the SDH (Draft).
G.8251: The Control of Jitter and Wander within the Optical Transport
Network (OTN).
417006-2304-0H3-B02
F-9
F-10
G.8201/Y.1354: Error performance parameters and objectives for multioperator international paths within the Optical Transport Network (OTN)
417006-2304-0H3-B02
417006-2304-0H3-B02
F-11
F-12
417006-2304-0H3-B02
417006-2304-0H3-B02
F-13
TMF 814: Multi Technology Network Management Solution Set V 2.1 and
V 3.5.
TMF 854: The MTOSI XML Solution Set Package Release 1.1.
F-14
417006-2304-0H3-B02
Index
16- to 32-Channel Mux/DeMux
Expansion C-2
C
Cable and fiber guiding accessories
A-26
cable guide A-26
cable guiding rods A-28
optical fiber guides A-27
Cable and Fiber Guiding Accessories
A-26
Cable and Fiber Preparation 4-23
Cable Guide A-26
Cable Guiding Rods A-28
Cable preparation
alarm 4-30
DC power 4-28
grounding 4-24
management 4-31
timing (clock) 4-31
Cable routes, xRAP-100 4-82
Card and Module Installation 6-1
Card failure 9-32
Card Installation Precautions 6-3
Cards and modules
installation, general 6-1
preparation 6-10
I-1
Index
417006-2304-0H3-B02
Index
D
Data network commissioning tests 8-27
required equipment 8-27
test sequence 8-27
tests
alarm handling 8-31
frame loss rate 8-29
stability 8-30
system recovery and reset 8-30
throughput and latency 8-28
Data Network Commissioning Tests
8-27
DC Input Power Connectors B-2
DC power cables 4-28
input power cables
connecting to xRAP 4-78
connecting to xRAP-100 4-85
preparation 4-76
preparation for xRAP-100 4-83
shelf power cables
xRAP 4-79
xRAP-100 4-87
DC Power Cables 4-28
417006-2304-0H3-B02
E
E1 Patch Panel Data B-14
EIS 6-34
optical transceiver installation 6-34
Electrical interface, connecting traffic
cables 7-17
Electricity Safety Warning 1-16
EMS-XDM Checklists 9-9
Environmental and Health Concerns
1-31
Environmental Considerations 4-17
Environmental requirements 4-2
Environmental Requirements 4-2
Environmental Standards F-2
EPA 1-28
Equipment grounding 1-10
Equipment Grounding Requirements
1-10, 1-18
Equipment Power-on Test 8-16, 8-34
Equipment racks, installation 4-37
extendable rails 4-42
floor marking 4-37
installation on concrete floors 4-40
installation on raised floors 4-41
installation on wooden floors 4-40
I-3
Index
F
F-CHANNEL Connector B-5
Features and Functions 2-3
Fiber Storage Tray See FST
Flow of Management Traffic D-6
Frame Loss Rate Test 8-29
FST A-25
installation 4-96
G
General 1-27
General Safety Requirements 1-5
General Troubleshooting Procedures for
Cards and Modules 9-13
General Troubleshooting Procedures for
Optical Transceiver Plug-ins 9-15
Go-Global Test 8-42
Grounded Conductors Requirements
1-19
Grounding
cable preparation 4-24
equipment 1-10
requirements 1-7
I-4
xRAP 4-77
xRAP-100 4-84
Grounding Cables 4-24
Grounding Requirements 1-7
Grounding the Platform 5-3
Grounding the Rack 4-42
H
Handling Transmission Alarms Test
8-22
Hardware Checklists 9-10
Hardware Preventive Maintenance 9-5
Heat Buffer A-26
HLXC/XIO Redundancy Test 8-25
I
I/O cards and modules 6-90
IEC
International Electrotechnical
Commission F-3
IEEE
Institute of Electrical and Electronic
Engineers F-4
IETF
Internet Engineering Task Force F-5
Implementation Principles 2-4
Input Power Cables 4-28
Input power cables for user-provided
distribution panel 4-29
Input Sensitivity Test 8-14, 8-35
Installation Data for XDM-500 I/O Cards
and Associated Modules 6-6
Installation Warning 1-4
Installing
AUX 6-64
cards and modules installation,
general 6-1
EIS 6-34
equipment racks 4-37
FST 4-96
I/O cards 6-90
MECP 6-78
modules 6-92
417006-2304-0H3-B02
Index
OADM1&4 6-66
safety 1-1
XDM accessories A-1
DDF 4-101, A-33
ETSI rack 4-14
FST A-25
ODF A-29
ODF_HP A-31
xRAP A-4
XDM Shelf
connecting cables to electrical
interfaces
ATS cards 7-21
clock cables 7-20
coaxial cables 7-19
multicoax cables 7-18
multipair cables 7-17
connecting cables to optical
interfaces 7-2
connecting fibers to
MECP_OSC 7-7
connecting fibers to
OADM1&4 7-8
connecting fibers to ODF_HP
7-13
connecting fibers to OFA_R
7-9
connecting fibers to SIO16
7-9
ETSI 7-2
optical fibers 7-6
racks 7-5
connecting cables, general 7-1
installing 5-1
air filters 5-6
assembling in rack 5-2
connecting power and bay
alarm cables 5-10
xMCP 6-73
xRAP installation 4-73
xRAP-100 installation 4-82
Installing a Card in the CCP Cage 6-92
Installing Air Filters 5-6
417006-2304-0H3-B02
I-5
Index
I-6
ITU-T
International Telecommunication
Union F-7
ITU-T/Telcordia Statutory Warnings and
Requirements 1-19
J
Jewelry Removal Warning 1-6
L
Laser
classification 1-21
information 1-21
operating precautions 1-23
safety 1-22
Raman amplifiers 1-25
statutory warning 1-22
training 1-22
Laser Classification 1-21
Laser Device Operating Precautions
1-23
Laser Information 1-21
Laser Safety Requirements 1-21
Laser Safety Statutory Warning 1-22
LED indicator lights 9-27
LightSoft Checklists 9-10
LOS Detection Test 8-34
Loss of Signal (LOS) Detection Test
8-14
M
M2_21 Interface Module Connectors
B-18
M2_84 interface module B-12
M2_84 Interface Module Connection
Data B-12
M2_84 Interface Module Connectors
B-12
Main Equipment Dimensions 4-2
Maintenance 9-1
air filter preventative maintenance
9-7
preventative maintenance 9-2
417006-2304-0H3-B02
Index
417006-2304-0H3-B02
N
Network Commissioning 8-10
Network commissioning tests 8-10
Network Configuration 8-31
Network Implementation Considerations
D-2
Network Management Considerations
D-5
Network Timing Considerations D-5
Network Timing Synchronization Test
8-13
NIST
National Institute of Standards and
Technology F-12
North American Standards F-13
O
OADM1&4
connecting fibers 7-8
installation 6-66
Obtaining Technical Documentation
xviii
ODF A-29
ODF_HP A-31
overview A-31
physical description A-32
ODF_HP A-31
connecting fibers 7-13
instructions 7-14
safety 7-13
Optical Distribution Frames See
ODF
overview A-31
physical description A-32
OFA_R, connecting fibers 7-9
instructions 7-11
safety precautions 7-10
OHA Connector B-8
OMG
Object Management Group F-14
I-7
Index
Optical connectors
extractor tool 4-8
Optical Distribution Frames (ODFs)
A-29
Optical Fiber and Cable Installation and
Routing 7-1
Optical Fiber Guides A-27
Optical Fibers
connecting to MECP_OSC 7-7
connecting to OADM1&4 7-8
connecting to ODF_HP 7-13
connecting to OFA_R 7-9
connecting to SIO16 7-9
Optical fibers installation and routing,
general 7-1
routing and connecting 7-6
Optical interface, connecting traffic
cables 7-2
Optical network commissioning tests
8-31
network configuration 8-31
test setup and required equipment
8-32
tests
BER and stability 8-38
equipment power-up 8-34
input sensitivity 8-35
LOS detection 8-34
maintenance action 8-37
optical power measurement 8-33
path protection 8-36
Optical Network Commissioning Tests
8-31
Optical Networks, upgrading and
expansion C-3
expansion checklist C-6
expansion process C-5
optical traffic capacity C-4
Optical Parameters Test 8-41
Optical Rack 4-13
optical transceiver 9-15
Optical transceiver replacement
guidelines 9-60
I-8
P
Patch Panel for Balanced Interfaces
A-35
Path Protection and Nonretrieval
Operation Test 8-18
Path Protection Test 8-36
Personnel Training 1-27
Physical description A-32
Physical location 4-5
Physical Location 4-5
Platform Connectors B-2
Platform DC Input Power Connectors
B-21
Platform Power Cables 4-29
Platform Power-On Test Procedure 8-10
Power
consumption 4-6
Power cables
connecting to XDM shelves 5-10
DC input to xRAP-100 4-82
Power Consumption Data 4-6
Power supply requirements 1-11
Connection via User-Provided Power
Distribution Panel 1-11
Connection via xRAP/xRAP-100
1-11
Power Supply Requirements 1-11
Preliminary Preparations 3-2
417006-2304-0H3-B02
Index
417006-2304-0H3-B02
Q
Qualified Personnel Warning 1-3
Quarterly checklist 9-9, 9-10, 9-11
R
Rack
assembling XDM shelves 5-2
cable routing 7-5
ETS1 4-14
installing 4-37
Rack Alarm Panel Power and Alarm
Connection Options A-4
Rack Grounding Requirements 1-8
Rack Space Requirements 4-12
RAP Connectors B-30
Rap Features A-5
RDR Test 8-41
Recommended Cleaning Methods 9-7
Recommended Integration Procedures
D-8
Related Documentation xvii
Replacement
components
cards, modules, fans , and other
components 9-43
I/O cards 9-59
MECP 9-57
NVM 9-52, 9-56
optical transceivers 9-59
optical plug-in transceiver
9-60
xECB 9-50
xFCU 9-48
xINF 9-49
xINF-H 9-49
xMCP 9-53
xRAP circuit breakers 9-45
xRAP-100 circuit breakers
9-46
modules 9-62
network element 9-40
Replacing a Network Element 9-40
I-9
Index
I-10
S
Safety
ESD protection 1-26
general 1-27
personnel training 1-27
temporary EPA 1-28
work arrangements in temporary
EPA 1-30
general requirements 1-5
grounding 1-7
equipment grounding 1-10
laser 1-21
information 1-21
operating precautions 1-23
Raman amplifiers 1-25
training 1-22
warning labels 1-21
power supply 1-11
user-provided power distribution
panel 1-11
xRAP/xRAP-100 1-11
UL statutory warnings and
requirements 1-17
equipment grounding 1-18
grounded conductors 1-19
UL 1-17
UL overcurrent protection 1-18
warning label 1-17
Safety and Workmanship 9-43
Saving EMS-XDM Configuration Files
9-40
SDH Network Commissioning Tests
8-10
Security Test 8-39
Severity Assignment Test 8-21
SEVERITY IN Connector B-40
SEVERITY OUT Connector B-41
SHELF Alarm Connectors B-21
SHELF ALARM Connectors B-35
417006-2304-0H3-B02
Index
417006-2304-0H3-B02
T
T3_1/T4_1 and T3_2/T4_2 Connectors
B-6
Technical Assistance xviii
Technical support xviii
Test Sequence 8-12, 8-27
Test Setup and Required Test Equipment
8-32
Tests
commissioning tests 8-1
data network commissioning tests
8-27
management commissioning tests
8-39
network commissioning tests 8-10
optical network commissioning tests
8-31
site commissioning tests 8-5
Throughput and Latency Tests 8-28
Timing (clock) cable preparation 4-31
Timing (Clock) Cables 4-31
TMF
TeleManagement Forum F-14
Tools and Equipment 8-2
Tools and test equipment
extractor tool for optical connectors
4-8
traffic cable tools 4-8
unpacking 4-9
visual inspection after unpacking
4-9
Tools and Test Equipment 4-8
Tools for Traffic Cable Assembly 4-8
Traffic 9-31
Traffic cables
connecting to optical interfaces 7-2
tools 4-8
I-11
Index
I-12
U
UL
equipment grounding requirements
1-18
listing 1-17
overcurrent protection safety 1-18
requirements for grounded conductors
1-19
warning label 1-17
Understanding the Aurora-G LED
Indicators 6-85
Unpacking 4-9
Unpacking and Visual Inspection 4-9,
6-80
Upgrades and Expansions C-1
16-channel to 32-channel mux/demux
C-2
optical networks C-3
Upgrading and Expanding Optical
Networks C-3
Upgrading to an Optical Module with a
Removable SFP 6-19
Upgrading to Optical Modules with
Removable SFPs 6-15
Uploading the NE Database from the
XDM-500 9-40
Use of Temporary EPA 1-28
Using Electrical Interface Protection
Modules 6-9
Using XDM Equipment to Transport
SYNCOM Traffic D-2
417006-2304-0H3-B02
Index
V
Visual Inspection and Mechanical Checks
8-6
Voltage test
xRAP 4-81
xRAP-100 4-89
W
Warning Definition 1-2
Warning Label 1-17
Warning labels 1-17
Warning Labels for Laser Products 1-21
Web Protocol Standards F-14
Weekly checklist 9-9, 9-10
Work Arrangements within a Temporary
EPA 1-30
X
XDM accessories
cable and fiber guides A-26
DDF A-33
ETSI rack 4-14
FST A-25
ODF A-29
ODF_HP A-31
xRAP A-4
XDM Accessories A-1
XDM integration in SYNCOM networks
D-1
network management D-5
network timing D-5
recommended integration procedures
D-8
XDM Product Lines 2-2
XDM Rack Alarm Panel See xRAP
XDM Rack Installation Options 4-10
XDM shelves 5-1
connecting cables 7-1
connecting DC power cables 4-87
installation 5-1
air filters 5-6
assembling in rack 5-2
grounding 5-3
417006-2304-0H3-B02
XDM-500 2-7
XDM-500 Installation Overview 3-1
XDM-500 Platform Installation 5-1
XDM-500 Slot Utilization 6-4
xECB connectors B-5
F-CHANNEL B-5
OHA B-8
OW B-7
T3_1/T4_1 B-6
T3_2/T4_2 B-6
xECB Connectors B-5
xMCP Redundancy Test 8-24
xMCP, installation 6-73
xRAP A-4
connecting power and bay alarm
cables to XDM shelves 5-11
connectors B-28
CONTROL CONNECTION
B-31
RAP B-30
SHELF EXTERNAL
ALARM/CONTROL B-28
installation 4-73, 4-77
alarm cables 4-81
circuit breakers 4-80, 9-45
connecting DC power cables
4-79
connecting input power cables
4-78
input power cables
preparation 4-76
grounding 4-77
xRAP Connector B-4
xRAP input power cables 4-28
xRAP-100 A-19
circuit breakers 9-46
connecting power and bay alarm
cables to XDM shelves 5-11
connectors B-28
ALARM IN/OUT B-36
SHELF ALARM B-35
SHELF DC power B-34
installation 4-82, 4-83
I-13
Index
I-14
417006-2304-0H3-B02