Sie sind auf Seite 1von 54

Service Manual

Model : SM -5100
July2009 2nd Version

SHANGHAI TERAOKA ELECTRONIC CO., LTD


SERVICE AND SUPPORT DEPT.
3rd Floor of 2nd Building, Jia Yuan Business Center,
51# Long Wu Road, Shanghai China 200232.
TEL : +86-21-6408-5151
FAX : +86-21-6408-3468
EMAIL ADDRESS :steservice@digi-scale.com

SM 5100

GENERAL

1. GENERAL

1.1 OVERALL VIEW


Bench

290
385

40

581.7

316

287
146.6

Pole

341.5
445

385

287

341.5

445

146.6

SM 5100

GENERAL

Elevated

146.6

492

130

317

385

470

1.2 DISPLAY PANEL

SM 5100

GENERAL

1.3 KEY PANEL


z

32 Preset Key
TARE

kg

WEIGHT

kg

UNIT PRICE

ZERO FIX T
FIX P
NET

$/kg

TOTAL PRICE

LABEL

FIX


C
z

7 PLU

56Preset Key

FIX


C

7 PLU

SM 5100

GENERAL

1.4 KEY DEFINE


ON/OFF KEY

Turn display "ON" or "OFF".

PRESET KEY

P1~P32(BCS)
P1~P32(BCS+)
P1~P56(PCS)
P1~P56(PCS+)

Set up or call either unit price and tare value.

NUMERIC KEYS

0~9

Enter numeric data.

TARE KEY
Set or Clear Tare value.
Select "NO" in S and Z Mode.
Item test print in S Mode.
CLEAR KEY

For Back space or Clear numeric value.


Select "YES" in S and Z Mode.

RE-ZERO KEY

Reset weight to ZERO.

PREPACK KEY

AUTO

Switch Manual mode and Pre-pack mode alternatively.


(The mode status will be indicated in the P and M indicator.)
P - PRE-PACK MODE
M - MANUAL MODE

CHANGE KEY
Calculate the Changed Amount.
Escape the Programming screen without saving data in S Mode.

SM 110

GENERAL

MULTIPLLE KEY

Register the number of Non-Weight products.


Select programming item such as PLU data, Shop Name in S Mode.
Select Report Type in X Mode.
Select Data Transaction Type in Z Mode.

CLERK KEY

V1~V4

Accumulate the Total Price.(PCS/PCS+ version)

VOID KEY

Correct the sales data.

PLU KEY

PLU

Call up PLU data in R Mode.


Store the programmed data in S Mode.

FEED KEY

Feed Label or Receipt paper

PRINT KEY

Print out Label or Receipt.

MODE SELECT KEY


Five Modes can be selected using this key.

Indicator R - REGISTRATION MODE (All the sales transactions are


performed.)

Indicator X - CHECK MODE (Printing out and sales report.)

Indicator S - PROGRAM MODE (Programming preset data, such as


products, data, shop name, etc.)

Indicator Z - TOTAL MODE (Clear sales data stored.)

Indicator X (Blink) - Password Setting Mode (Set PASS WORD for X,


S, Z mode, set PASSWORD for PASSWORD MODE when all
indicators(R, X, S, Z) blink)

SM 110

GENERAL

Decrease/Increase Specification Count key

Decrease/Increase Only used when Setting SPEC 141 & 142

<<,>>

Select parameter data such as SPEC data. Move cursor left or right.

1.5 Indicators
z

ZERO

: On when zero point is adjusted and weight is stable.

NET

: On when tare subtraction is performed.

FIX T

: On when tare weight is fixed.

FIX P

: On when PLU or unit price is fixed.

: On when pre-pack mode is chosen; indicate capital letter is use in PLU programming.

: On when manual mode is chosen.

V1 ~ V4

: On when vendor transaction entries (department entry or PLU entry) are performed.

LABEL

: On when label printing mode is chosen.

: On when in R (normal operation) mode.

: On when in X (read report) mode.

: On when in S (programmable item setting) mode.

: On when in Z (reset report and system maintenance) mode.

1.6 FEATURES
z

Digital printing scale consists of electronic cash registers function and label printing function.

High-speed, high reliability thermal head printer.

Easy paper handing achieved special designed mechanism.

Built-in clock automatically updates date and time.

Quick response to weight changes.

Capacity

: 3kg, 6kg, 12kg, 15kg, 30kg, 6lb, 12lb, 15lb and 30lb.

Resolution

: Display Resolution 1/3,000.

: Internal Resolution 1/90,000.

Calibrating by software.

Customer and operator displays (optional customer pole display).

Character type with back-light for numeric and character display.

Matrix type with back-light for numeric and character and Chinese character display.

55 (bench and pole type) / 83 membrane keys

a. ON/OFF key.

b. 10 Numeric keys, to key in numeric data.


9

SM 110

GENERAL

c. 32/56 Preset keys, to preset PLU or function into the key.

d. 23/27 Operational keys, to perform various functional operations.

18 data files for Department, Main Group, PLU, etc.

Various reports.

Ethernet function.

Optional wireless Ethernet card.

RS232C interface for data communication and barcode scanner connection.

Optional cash drawer.

Compact housing.

1.7 SPECIFICATION
1.7.1 Display
z Matrix type with back-light for numeric and character and Chinese character display.
z Tare Weight display

: 4 digits.

z Weight display

: 5 digits.

z Unit Price display

: 6 digits.

z Total Price display

: 7 digits.

1.7.2 Operating Conditions


z Power Source

: AC 176V ~ 264V, 47~63Hz.

z Operating Temperature

: -10 C ~ +40 C.

z Operating Humidity

: 15% ~ 85% RH.

z Power Consumption

: 0.15A.

10

SM 5100

INITIAL SETUP

2. INITIAL SETUP
2.1 Paper Handing
Please press the button and take out the cassette to fix the paper when you need to use new
paper.

Cassette

Button

11

SM 5100

INITIAL SETUP

2.2 Bubble Adjustment and SPAN Switch

Place the scale on the flat surface and adjust the


four legs until the bubble on the level is in the
centre as shown above 1

Please remove the screw and use a insulate rod


to enable the Span SW when the scale is power
on and please do not power off it.

2.3 Memory Initialisation


Clear all of the memory.
DISPLAY
OPERATION

REMARK

TARE

lb

/lb

Z1.0

RESET

SALES

DAILY

[Re-zero]+[2][3][0]

CLEAR

PLU

FILE

PLU file.

[]

CLEAR

VENDER

DATA

Vender transaction data.

[]

CLEAR

REPORT

FILES

Report files.

[]

CLEAR

MEMORY

DATA

All files in memory.

[*]

CLEAR

MEMORY

Y-C N-T

RESET

SALES

DAILY

[C] or [T]

Z1.0

12

Z mode.
Lamp Z turns on.

[C] to clear file data,[T] to


quit.
Return to Z mode.

SM 5100

INITIAL SETUP

2.4 DEFAULT SPECIFICATION SETTING


Default SPEC setting of individual country.
(Please turn on the span switch before proceed this process.)
Country Set
DISPLAY
OPERATION

REMARK

TARE

lb

/lb

TARE

Z1.0

RESET

SALES

DAILY

[Rezero]+[8][8][2][2]

SPEC

2-STD

COUNTRY

[>>]

SPEC

1-U1

COUNTRY

DEFAULT

SPEC

Y-C N-T

SCALE

TYPE

POLE

[*]

LOAD

[C]

lb
Z mode.Lamp Z turns on.
Set country setting.
[>>],[<<] or [X] to select country.[*]
to update country setting.
[C]

to

load

default

SPEC

setting,[T] to skip.
Set scale type.
[X],[] to select type [11] or [12]

[X] [X]

SCALE

TYPE

BENCH

5100B or 5100P ,[*] to update type


setting.

[*]

SCALE

CAP.

3KG

[X]

SCALE

CAP.

15lb

[*]

SCALE

RES.

1/3000S

[X]

SCALE

RES.

1/3000M

[*]

CLEAR

MEMORY

Y-C N-T

RESET

SALES

DAILY

[C]

Z1.0

Set scale capacity.


[X],[ ] to select capacity,[*] to
update capacity setting.
Set resolution.
[X],[] to select resolution,[*] to
update resolution setting.
[C] to clear memory,[T] to skip.
Return to Z mode.

Note 1: For the first using of SM-5100, please take this operation for initialization.
Note 2: Enter a number that represent a country in the country list (refer to the table below)

to initialise and country set.

13

SM 5100

INITIAL SETUP

COUNTRY LIST
No. Country Code
0
AA
1
U1
2
STD
3
CN
4
HK
5
TW
6
EX
7
KE
8
AR
9
SF
10
CS
11
GC
12
TU
13
CV
14
HG
15
PL
16
UR
17
AS
18
DM
19
FL
20
NW
21
SD
22
PG
23
UK
24
IL
25
IL (LB)
26
CA
27
CA (LB)
28
AG
29
MX
30
BZ
31
CE
32
EA
33
JD
34
LN
35
IRN
36
CR
37
TL
38
EC
39
NL
40
BG

Country
No. Country Code
Japan
41
SA
U.S.A.
42
IC
Standard
43
IE
China
44
CB
Hong Kong
45
KY
Taiwan
46
IR
Export
47
VY
Korea
48
MS
Australia And New Zealand 49
SN
South Africa
50
VZ
Cyprus
51
CO
Greece
52
MA
Turkey
53
FR
Czech Republic
54
WG
Hungary
55
BL
Poland
56
BW
Russia
57
CP
Austria
58
LS
Denmark
59
MU
Finland
60
MW
Norway
61
MZ
Sweden
62
NM
Portugal
63
RE
United Kingdom
64
SH
Ireland (Kg)
65
SW
Ireland (Lb)
66
WZ
Canada (Kg)
67
ZW
Canada (Lb)
68
AE
Argentina
69
TT
Mexico
70
UD
Brazil
71
LV
Chile
72
CVS
Egypt
73
SK
Jordan
74
SV
Lebanon
75
UA
Iran
76
KZ
Canary Islands
77
IT
Thailand
78
SZ
European Community
79
ID
Netherlands
80
CD
Belgium

14

Country
Saudi Arabs
Iceland
Indonesia
Cuba
Kenya
Israel
Slovenia
Malaysia
Spain
Venezuela
Croatia
Macedonian
France
Germany
Bulgaria
Botswans
Comores
Lesotho
Mauritius
Malawi
Mozambique
Namibia
Reunion
Seychelles
Swaziland
Zimbabwe
Zambia
U.A.E
Trinidad and Tobago
Uganda
Latvia
Slovakia
Sri Lanka
Slovenia
Ukraine
Kazakhstan
Italy
Switzerland
India
New Caledonia

SM 5100

3.

CALIBRATION

CALIBRATION

Prior to Calibration, please refer that the specification indicating weight capacity, minimum
graduation, and load cell sensitivity are correctly set.
Caution:
z

It can only work when SPAN SWITCH is on (ENABLE).


Before Calibrating, please enter Z mode.

3.1 CALIBRATION OPERATION


DISPLAY
OPERATION
Press

SPAN

SWITCH

TARE

lb

/lb

Z1.0

RESET

SALES

DAILY

[Rezero]+[8][7][1][5]

After storing the zero

full

capacity

on

(ENABLE).
[8][7][1][5]

while

Calibrating zero point.

Calibrating Span.

------

weight on platter.[*]
After calibration

is

CAL SP

Point IR count
Put

SWITCH

depressing [Rezero].

------

platter,[*]

SPAN

Enter

CAL 00

Ensure no weight on

REMARK

Z1.0

RESET

SALES

15

DAILY

Go back to Z mode. Lamp Z


always light.

SM 5100

CALIBRATION

3.2 EXIT CALIBRATION


DISPLAY
OPERATION
Press

SPAN

SWITCH

TARE

lb

/kg

TARE

Z1.0

RESET

SALES

DAILY

[Rezero]+[8][7][1][5]

[T]

Z1.0

RESET

SALES

DAILY

Z1.0

RESET

is

on(ENABLE).
[8][7][1][5]

while

Escape to Z mode. Lamp Z


always light

as the zero point IR count.


Calibrating Span.

CAL SP

Point IR count

SWITCH

The IR count will be taken

------

After storing the zero

SPAN

depressing [Rezero].

CAL 00

[*]

lb

Enter

CAL 00

[Rezero]+[8][7][1][5]

[T]

REMARK

SALES

16

DAILY

Escape to Z mode. Lamp Z


always light.

SM 5100

SOFTWARE SETTING

SOFTWARE SETTING

4.1

SOFTWARE VERSION UPGRADE

Update Method Introduction


SM-5100 use flash RAM instead of EPROM for the main program storage of the scale.
Our boot program is above Version 2.00, we have two method to update the scales
software: update the scale by Ethernet or RS-232 So you can choose either method
between these two ones to update your scale.
Now we will set two parts to introduce the steps of these two updating methods.

Update Steps Introduction


1. Ethernet Update Method
1. Cable & Connection
There are also two ways to connect the PC and the scale in updating the scale by
ethernet.
1) PC to Scale

2) Connect by Hub

17

SM 5100

SOFTWARE SETTING

These two twisted cable obey the EIT/TIA 568 standard.

1
2
3
4
5
6
7
8

T568A line series


Green &White
Green
Orange & White
Blue
Blue & White
Orange
Brown & White
Brown

1
2
3
4
5
6
7
8

T568B line series


Orange & White
Orange
Green &White
Blue
Blue & White
Green
Brown & White
Brown

crossing twisted cable: one end with T568A line series, another with T568B line
series
normal twisted cable: two ends both with T568B line series

2 .PC Setting & Programmer Version


We use Mini Programmer (Version 2.00) as the tool to update the scale. As it
needs a default visual IP address for the PC by this kind of update method, You must
set your PCs IP address within the range of 10.10.10.1-----10.10.10.240, before you
start the software to update the scale.
If you dont set the IP address like this, you can see an alarm window as Pic. 1 when
you start Mini Programmer.

Pic. 1
2. Updating Steps
1) How to start ethernet updating?
A. Turn on the switch on the bottom of the scale.
B. Power off the scale by pressing On/Off Key.
C. After that, press and hold [Re-Zero] and [Preset 22], then start the scale by
pressing the On/Off Key.
D. The screen will display the version of the current boot program for two seconds.
E. Only in new versions(version of the boot program newer than 1.10), you
can choose 2-ethernet.
2) Display on the scales screen
A. If you choose 2 and the scales connection is correct, it will display waiting for
connect.
B. Then the message on the scales screen is getting IP address.
C. After this, it will display 001 scale ready update.
D. You cant stop it unless you press On/Off key. If you want to continue
updating. You also dont need to press any key on the scale until Mini
Programmer begin to run.
18

SM 5100

SOFTWARE SETTING

3) How to upload the scale by Mini Programmer?


A. Select SM-5100 and press ok

B. Set the port

Select ethernet and press OK

19

SM 5100

SOFTWARE SETTING

C. Download boot program and update the scale


Select menu File->Load File To Programmer Buffer

Open the source file of boot program (SM100+_Bv200.hex)

You can see a speed mode select window here.

Select menu Flash->Program

20

SM 5100

SOFTWARE SETTING

Notice: The message 001 scale ready update must be displayed on the
screen of the scale before pressing the run button.

After the transmission has completed, select menu File->Clear Buffer.

Notice: 1.If the boot program of this version is already in the scale, you dont
need to upload it again, skip it and upload the main program.
2.If the scale is updated from 1.xx to 2.xx,firstly you must update the
boot program of the version.
D. Download main program file
You must power off the scale and start the ethernet upload method again when
you have finished a program uploading.
The steps of uploading the main program file is also like uploading the boot
program file. The file you need to open is like Pic. 2

Pic. 2

21

SM 5100

SOFTWARE SETTING

E. Download word-stock file


The steps of uploading the word-stock file is also like uploading the boot program
file. The file you need to open is like Pic. 3

Pic. 3
F. Download const text file
The steps of uploading the const text file is also like uploading the boot program.
The file you need to open is like Pic. 4

Pic. 4
G. Exit Mini Programmer
Note: please update the scale according to sequence above.

22

SM 5100

SOFTWARE SETTING

4.3 RS232C Method


3. Cable Connection
3 Pins are used for data transmission between PC and SM-5100
9 Pin D-Sub Female Connectors for this cable:

PC Serial Port
9 Pin D-Sub (Female)

Pin
1
2
3
4
5
6-9

Signal
N.C.
RXD
TXD
N.C.
GND
GND

SM-5100 RS-232C
9 Pin D-Sub (Female)

Signal
N.C.
RXD
TXD
N.C.
GND
N.C.

Pin
1
2
3
4
5
6-9

4. Update Steps
1) How to start RS232C updating
A. Turn on the switch on the bottom of the scale.
B. Power off the scale by pressing the On/Off Key.
C. After that press and hold [Re-Zero] & [Preset 22], then start the scale by press
ing the On/Off Key.
D. It will display the version of the current boot program for two seconds.

E.
If the scale boot version is newer than 1.10, it will display a updating method
choice like 1-RS232 2-ETHERNET on the screen. you can press Numeric 1
to choose 1-RS232C.
If the boot version is older than 1.10, the scale will not display the choice.
F. Then the Scale will display PROGRAM. You cant stop it, unless you press
Tare or On/Off Key.
2) Start Mini Programmer
23

SM 5100

SOFTWARE SETTING

1.

Select SM-5100 and press Ok

2.

Set the Port:

Select RS232 and press OK

3.

Download the boot program and update the scale


Select menu File->Load File To Programmer Buffer

24

SM 5100

SOFTWARE SETTING

Open the source file of the boot program (e.g. sm100bv100.hex)

Select menu Flash->Program

Notice: The message 001 scale ready update must be displayed on the
scale before pressing the run button.

25

SM 5100

SOFTWARE SETTING

After the transmission has completed, select menu File->Clear Buffer.

Notice: If the boot program of this version is already in the scale, you dont
need to upload it again, skip it and upload the main program.

26

SM 5100

SOFTWARE SETTING

4.
Download main program file
You must power off the scale and start the ethernet upload method again when
you have finished a program uploading.
The steps of uploading the main program file is also like uploading the boot
program file. The file you need to open is like Pic. 2

Pic. 2
5.
Download word-stock file
The steps of uploading the word-stock file is also like uploading the boot program
file. The file you need to open is like Pic. 3

Pic. 3
6.
Download const text file
The steps of uploading the const text file is also like uploading the boot program.
The file you need to open is like Pic. 4

27

SM 5100

SOFTWARE SETTING

Pic. 4
7.

4.2

Exit Mini Programmer

SPECIFICATION SETTING

Before Specification setting, please press the mode button to enter Z mode.
The detail specification list , please see the appendix.

4.2.1

Customer SPEC Setting

To change setting of the Customer SPEC if there are some SPEC setting in it need to be alter.
DISPLAY
OPERATION

[Rezero]+[1][4][1]

[]

TARE

lb

/lb

Z1.0

RESET

SALES

DAILY

SPEC

XXX

XXX

000

(setting)

(former)

SPEC
001

REMARK
Z mode.
Lamp Z turns on.
Enter [1][4][1] while depressing
[Rezero].
XXX:SPEC data
[]key only increase specification

XXX

XXX

count, it does not update SPEC


data.

[]

SPEC
000

[
XXX

XXX

]key

only

decrease

specification count, it does not


update SPEC data.

[1][7]
[X]

SPEC

017

XXX

It goes to a designed specification

000

XXX

XXX

count.

28

SM 5100

SOFTWARE SETTING
SPEC

(000~441 is enabled)

017
SPEC

[>>]

017
SPEC

[<<]

017

XXX

XXX

XXX

XXX

[>>] key select SPEC data.


Move cursor right.
[<<] key select SPEC data.
Move cursor left.

SPEC
[1]

017

001

XXX

[*]

SPEC

XXX

XXX

000

XXX

SALES

DAILY

018
SPEC

[C]

018

[PLU]

Z1.0

* Note 1

* Remark:

4.2.2

RESET

Clear the enter data.

Store the updated specification


and escape to Z mode.

The Weight in the display window will display the SPEC number. The Unit
Price window will display the new value setting entered. The Total Price
window will display the old value setting. The selection you have made will
be highlighted in the dot matrix display. Please use [] to increase spec
count, [] to decrease spec count, [*] to store a new value and [PLU] to save
spec setting.

Weight & Measurement SPEC Setting

To change the setting of the Weight & Measurement SPEC if there are some SPEC need to alter.
(Please turn on the span switch when using this process)
DISPLAY
OPERATION
Press SPAN
SWITCH

[Rezero]+[1][4][2]

[]

TARE

lb

/lb

Z1.0

RESET

SALES

DAILY

SPEC

XXX

XXX

600

(setting)

(former)

SPEC
601

REMARK

SPAN SWITCH is on(ENABLE).


Enter [1][4][2] while depressing
[Rezero].
XXX:SPEC data
[]key only increase specification

XXX

XXX

count, it does not update SPEC


data.

[]

SPEC
600

[
XXX

XXX

]key

only

decrease

specification count, it does not


update SPEC data.

[6][1][5]

SPEC

615

XXX
29

It goes to a designed specification

SM 5100

SOFTWARE SETTING

[X]

600

XXX

XXX

SPEC

count.
(600~709 is enabled)

615
SPEC

[>>]

615
SPEC

[<<]

615

XXX

XXX

XXX

XXX

SPEC

[>>] key select SPEC data.


Move cursor right.
[<<] key select SPEC data.
Move cursor left.
[*] key to update specification,

[1]

615

001

XXX

[*]

SPEC

XXX

XXX

002

XXX

000

XXX

SALES

DAILY

increase specification count.

616
SPEC

[2]

616
SPEC

[C]
[PLU]
* Note 1

616
Z1.0

RESET

Clear the enter data.

Store the updated specification


and escape to Z mode.

Note 1: If press [T] key, it does not store the updated specification and escape to Z mode.

* Remark:

The Weight in the display window will display the SPEC number. The Unit
Price window will display the new value setting entered. The Total Price
window will display the old value setting. The selection you have made will
be highlighted in the dot matrix display. Please use [] to increase spec
count, [] to decrease spec count, [*] to store a new value and [PLU] to save
spec setting.

30

SM5100

INTERFACE

5. INTERFACE
5.1

PC INTERFACE

SM 5100 can be connect to PC through Ethernet interface and RS232C. See below for the
connection method.

CONFIGURATION OF PC ETHERNET CARD


Window version client driver
Any Ethernet cards can be used for PC running the Window version client driver
Windows 98
My Computer Control Panel NetworkTCP/IP of Ethernet card (Select
Properties)
IP address : 192.168.1.XXX ------ XXX - can be any number. But preferable 100 to 255.
Submask : 255.255.255.0
Above IP address is use as a standard address to use for SM 5100 Ethernet
communication.
If whatever reason, the IP address had to be change, it may do so. But the scale IP address
had to be change at the SM 5100 scale also so that they are within the same network. Eg. If
the computer IP address is 192.168.1.XXX, the SM 5100 scale IP address has to be change
to 192.168.1.XXX. The last three digits of the IP address should not be similar within the
computer and scales at all time. As can see the first three set of number of the IP address of
the computer and scale must be the same.

31

SM5100

INTERFACE

Before setting the SPEC setting of the scale, please check below.

5.2

SCALE ETHERNET ADDRESS

The main board have a Scale Ethernet Address that is set during production. This address
is a hardware setting for Ethernet communication. But when changing a new main board,
the new main board did not have any this address. If the scale is using Ethernet
communication, a Scale Ethernet Address is needed apart from software IP address.
Please take note that the Scale Ethernet Address can only input once after saving. Please
view and note down the Scale Ethernet Address of the old main board before changing the
new main board. Below procedure is to view and input the Scale Ethernet Address. Please
turn on the span switch before proceed.
KEY TO PRESS
TARE

lb

DISPLAY
/lb

OPERATION

Go to Z mode
[REZERO] +
[0][6][1][2]

Z1.0
ETHER

RESET
NET

SALES
.

Daily
.

[0][0][0][6][C][0]
[0][0][0][0][2]
[4]
[PLU]

ETHER

NET

0006C

0000024

Z1.0

RESET

SALES

Daily

[T]

Z1.0

RESET

SALES

Daily

Power off the


scale

* IMPORTANT :

At Z mode
Viewing of Ethernet
address For new main
board, it can act as input
of the address if the
address shown ..
Else it would not let you to
input.
For input only. Enter
Ethernet address e.g.
0006C 0000024
Save address and escape
to Z mode. After saving it
will not be able to input
again.
Escape to Z mode without
saving.
Turn off the power and do
the memory clear
process.

Please take note that this is a one time setting. It cannot be change after
setting it. Please check the old address and input accordingly. As same
internal Ethernet address in a network may conflict during
communication.

32

SM5100

5.3

INTERFACE

SCALE IP ADDRESS

This is to set the IP address for PC communication using Ethernet for specific IP address. It
should not be confused with the Scale Ethernet Address as above. The Scale Ethernet
Address is mainly for hardware and Scale IP Address is for software. The software when
communicating to the scale must specify the same IP address on the scale else it will give
error. The default is 192.168.000.000 where the last three digit will change when SPEC 135
change. Please turn on the span switch before proceed.
KEY TO PRESS
TARE

Go to Z mode
[REZERO] +
[0][4][1][6]
[1][9][2][1][6][8]
[0][0][1][0][1][6]

lb

DISPLAY
/lb

OPERATION

Z1.0
SCALE

RESET
IP

SALES
.

Daily
.

SCALE

IP

192168

001016

[PLU]

Z1.0

RESET

SALES

Daily

[T]

Z1.0

RESET

SALES

Daily

33

At Z mode
Input or viewing of IP
address
Enter IP address e.g.
192.168.001.016
( The last 3 digits cannot
be input as it will change
when SPEC 135 change)
Save address and escape
to Z mode
Escape to Z mode without
saving.

SM5100

5.4

INTERFACE

CONNECTION METHOD

5.4.1 RS232C Interface with PC


PC

Scale

Com 1 / Com 2

RS232C Port

* Note : Only 1 scale can be connect in this method.


SPEC setting on scale :
SPEC 48

Scale number (For 4 line / RS232C port)

Enter number between 1 to 999,999

SPEC 51
0
1

7 bit

SPEC 53
0

None

SPEC 54
0

2
3

4800
9600

4
5

19200
38400

Even

76800

SPEC 52
0

Baud rate for SIO (RS232C port)

1200
2400

1 bit

Data length for SIO (For RS232C port)


1

8 bit

Parity for SIO (For RS232C port)


1

Odd

Stop bit for SIO (For RS232C port)


1

2 bits

34

SM5100

5.4.2

INTERFACE

Ethernet Connection (Ethernet Interface)

Scale #1
Scale #5

Scale #2

Scale #3

Scale #4

PC

HUB

SPEC setting on scale :


SPEC 49
0
1
2

No interface
Ethernet - Coaxial Cable
Ethernet - Twisted Cable

SPEC 50
0
1

CLIENT / SERVER INTERFACE


Not used
4 lines, RS485 (For future use)

Back-up server

CLIENT / SERVER

Client
Server / Workstation

SPEC 135

3
4

PORT NUMBER

* Enter number from 1 to 254

35

SM5100
5.5

INTERFACE

WIRE CONFIGURATION

5.5.1 Ethernet Wire - Straight Cable and Crossover Cable


Straight cable is for Client / Server connection. Crossover cable is for Hub to Hub
connection. (Some models of the hub do not need crossover cable for hub to hub
connection. Please refer to the hub operation manual if in doubt)
Telephone Modular Plug (Category 5) -

Preferable type :

CviLux CJP3 / CviLux CJP4 (with insert bar)

CABLE TYPE Cable type

Preferable type :

4 pair 100MHz Cat.5 AWG 24 or 26 UTP / FTP / STP.


Cat. 5 AWG 24 or 26 FTP / Cat. 5 AWG 24 or 26 STP
(Recommended for CISPR 22B conformance)

PIN CONFIGURATION
1

SM 5100

HUB
8

1
Solder to braid wire of the Ethernet
wire if using plug without insert bar

SM 5100
8

HUB
Solder the braid wire of the Ethernet
wire if using plug with insert bar

STRAIGHT CONNECTION
SCALE
PIN SIGNAL
1
TX+
2
TX3
RX+
6
RX5,7,8
N.A.

CROSSOVER CONNECTION

HUB

HUB

SIGNAL PIN
TX+
1
TX2
RX+
3
RX6
N.A.
5,7,8

PIN
SIGNAL
1
TX+
2
TX3
RX+
6
RX5,7,8
N.A.

36

HUB
SIGNAL
TX+
TXRX+
RXN.A.

PIN
3
6
1
2
5,7,8

SM5100

INTERFACE

5.5.2 RS232C Wire


PC (9 PIN) TO SCALE RS232C PORT

RS232C Port9 Pin

Pin
1
2
3
4
5
6
7
8
9

5.5.3

PC COM Port9 Pin

RS-232

Not used
RXD
TXD
DTR
GND
DSR
DTR
DSR
Not used

PC

Not used
TXD
RXD
Not used
GND
Not used
Not used
Not used
Not used

Pin
1
2
3
4
5
6
7
8
9

Cash Drawer Connector

SM-5100 uses normal phone mike plug to connect cash drawer and the scale.
1 pin
4 pin

1 pin
4 pin

Plug in the scale


Pin
Output
1
Not used.
2
+8V
3
GDD
4
Not used.

Connector of Cash Drawer


Input
Pin
Not used
1
Voltage +
2
GDD
3
Not used
4

37

SM 5100

MISCELLANEOUS

6.

MISCELLANEOUS

6.1

MODE CHANGE

To toggle between R, X, S, Z and Password mode.


DISPLAY
OPERATION
TARE

lb

/lb

0.000

0.000

0.00

0.00

[MODE],[MODE]

XMODE

(within 3 seconds)

REMARK
Weight mode. Lamp R turns on.
Enter X mode. Lamp X turns on.

[MODE]

S1

PLU

FILE

Enter S mode. Lamp S turns on.

[MODE]

Z1.0

RESET

SALES

DAILY

Enter Z mode. Lamp Z turns on.

PWD X

SET

0.000

0.00

0.00

[MODE]
[MODE]

0.000

Enter Password Set mode. Lamp


X flicker
Back to Weight mode. Lamp R
turns on.

* The X mark on the X, S, Z and R mean the indicator light is on. When in Password mode,
the indicator light will be blinking.
** The scale goes back to R mode as normal when the net weight is 0.
***If the scale weight is not equal to 0, error message "E18 PLEASE REMOVE WEIGHT" is
displayed.
1) There is some items on the platter. The scale will go back to R mode if the item is removed.
2) There is nothing on the platter, but the net weight is not equal to 0.
The operator has to press [Rezero] key manually (Tare will auto clear when rezero), then the scale
will go back to R mode if rezero operation is successful.

6.2

SPAN SWITCH STATUS

Check the status of span switch.


DISPLAY
OPERATION

Go to Z mode

TARE

lb

/lb

Z1.0

RESET

SALES

DAILY

STE16

VX.XX

S-OFF

RESET

SALES

DAILY

[Rezero]+[2][8][4]
Z1.0

38

REMARK
Z mode.
Lamp Z turns on.
Enter [2][8][4] while depressing
[Rezero].
Exit after 3 seconds.

SM 5100
6.3

MISCELLANEOUS

CLEAR ALL PLU DATA

To clear all the PLU data only, the span switch status must be on.
DISPLAY
OPERATION

REMARK

TARE

lb

/lb

Z1.0

RESET

SALES

DAILY

[Rezero]+[2][3][0]

CLEAR

PLU

FILE

CLEAR

PLU

Y--C N--T

RESET

SALES

DAILY

Go to Z mode

C(T)

6.4

Z1.0

Z mode.
Lamp Z turns on.
Enter [2][3][0] while depressing
[Rezero].
Enter C for Yes, Enter T for No..
Back to Z mode

THERMAL HEAD USAGE

To check how many times the thermal head had been printing.
DISPLAY
OPERATION
TARE

lb

/lb

Z1.0

RESET

SALES

DAILY

USAGE

SALES

DAILY

PRINTE

[Rezero]+[0][8][2][3]
[T]

6.5

R
Z1.0

RESET

REMARK
Z mode.
Lamp Z turns on.
Display

thermal

printer

usage

condition(meter).
[T] key to exit.

IP ADDRESS

To check and modify the scale IP address.


DISPLAY
OPERATION

[Rezero]+[0][4][1][6]
[1][9][2][0][0]
[9][1][0] [0]

TARE

lb

/lb

Z1.0

RESET

SALES

DAILY

Scale

IP

Scale

IP

192168
00
192009
10

[#]

000
000
----------

39

REMARK
Z mode.
Lamp Z turns on.
Display the scale IP address.
Modify the IP address.
Save the new IP address.
Press [T] key to exit.

SM 5100
6.6

MISCELLANEOUS

SERVER IP ADDRESS

To check and modify the server IP address.


DISPLAY
OPERATION

[Rezero]+[0][4][1][7]
[1][9][2][0][0]
[9][1][0] [0]

TARE

lb

/lb

Z1.0

RESET

SALES

DAILY

SERVER

IP

SCALE

IP

2552552
5
1920091
0

[#]

6.7

5000
0000
----------

REMARK
Z mode.
Lamp Z turns on.
Display the server IP address.
Modify the server IP address.
Save the new IP address.
Press [T] key to exit.

SUBNET MASK

To check and modify the subnet mask.


DISPLAY
OPERATION
TARE
Z1.0
[Rezero]+[0][4][1]8]
[1][9][2][0][0]
[9][1][0] [0]

lb
RESE
T

SERVER

IP

SCALE

IP

/lb

SALES

DAILY

2552552
5
1920091
0

[#]

6.8

5000
0000
----------

REMARK
Z mode.
Lamp Z turns on.
Display the server IP address.
Modify the server IP address.
Save the new IP address.
Press [T] key to exit.

MAC ADDRESS

To check the MAC address.


Please turn on the span switch before proceed.
DISPLAY
OPERATION
/lb
TARE
lb
Z1.0
[Rezero]+[0][6][1]2]
[T]

RESET

SALES

ETHERN

0006C07

ET

Z1.0

RESET

SALES

40

REMARK

DAILY
96BE
DAILY

Z mode.
Lamp Z turns on.
Display the MAC address.
Press [T] key to exit.

SM 5100

MISCELLANEOUS

* It can only work when SPAN SWITCH is on (ENABLE).


Before Calibrating, please enter Z mode.

6.9

SERIAL NO.

To check the serial NO.


DISPLAY
OPERATION
lb

/lb

Z1.0

RESET

SALES

DAILY

SCALE

S/N

05386686

RESET

SALES

DAILY

[Rezero]+[1][1][1]
[T]

6.10

REMARK

TARE

Z1.0

Z mode.
Lamp Z turns on.
Display the serial NO..
Press [T] key to exit.

ASCII CHARACTER

Below are the common use of characters of ASCII code in HEX value. Please enter the
hex value when entering commodity name, advertisement, shop name, clerk name,
special message, ingredient, text etc. when using the SM-5100.
A
41
N
4E
a
61
n
6E
0
30
$
24
>
3E

B
42
O
4F
b
62
o
6F
1
31
%
25
=
3D

C
43
P
50
c
63
p
70
2
32
^
5D
/
2F

D
44
Q
51
d
64
q
71
3
33
&
26
?
3F

E
45
R
52
e
65
r
72
4
34
*
2A

2E

F
G
H
46 47 48
S
T
U
53 54 55
f
g
h
66 67 68
s
t
u
73 74 75
5
6
7
35 36 37
:
(
)
28 29 3A
, Spac
2C 20

41

I
49
V
56
i
69
v
76
8
38
;
3B

J
4A
W
57
j
6A
w
77
9
39
"
22

K
4B
X
58
k
6B
x
78
!
21
'
27

L
4C
Y
59
l
6C
y
79
@
40
+
2B

M
4D
Z
5A
m
6D
z
7A
#
23
<
3C

SM5100

ERROR MESSAGE

7. SM5100 ERROR MESSAGE

The machine beeps and following error messages appear on display, if


incorrect operation is performed.
No.

Error Message

Cause

PAPER END

Label sensor sense no label. No more labels.


Replace label roll

FEED PAPER FIRST

Label miss feed, press FEED key to align label.

PEEL LABEL

Peel sensor activated, remove label away from sensor.

CHANGE PAPER

Change paper mode between label and receipt.

NON PRINT

No manual printing.

UNIT PRICE OVERFLOW

Please check unit price.

NON LABEL

No free format is programs. Set a free format or


use standard format.

12

MEMO NOT INITIALIZED

Memory problem. Please clear the memory.

14

HEAD IS NOT CLOSED

Thermal head no closed. Please close thermal head.

16

FILE MEMORY FULL

Not enough memory. Expand memory or


delete unnecessary data.

18

PLEASE REMOVE WEIGHT

Fixed price item, please remove weigh.

19

PLU NOT EXIST

No such PLU data or number exists.

20

TOTAL PRICE IS 0

24

WEIGHT OF

Weight over maximum capacity when print.

26

TOTAL PRICE OVERFLOW

Total price over the limit to display or print.

29

PLEASE SET TARE VALUE

39

PLEASE PRESS PLU KEY

When force tare is enable, a tare weight must be


d
Press PLU(#)
key. To save data in some procedure.

44

KEY ALREADY ASSIGNED

Preset key already been assigned with function or

48

PLU DATA INVALID

U1 only. Quantity setting incorrect when using FOR.

49

QTY OF

Quantity data over the limit.

54

BELOW MIN WEIGHT

Weight is below min weight set when printing.

57

PRICE ACC OF

Accumulated quantity over the limit.

59

PLEASE SEE LABEL QTY

Set print label quantity when the function is use.

61

GRAND TOTAL OF

Grand total price over the limit.

71

PRINT INHIBITED

Cannot print weigh item at Prepack mode.

74

SELF SERVICE MODE

Can only use Self-service procedure only.

95

CAL00 ERROR

Zero point calibration error.

96

CALSP ERROR

Full scale point Calibration error.

97

FORMAT ERROR

No free format is program.

98

NO DATA IN REPORT

There is no data in report when printing report.

99

EXCEED WEIGHT QUOTA

CN only. Please reset weight quota.

No total price for item. Unit price, weight or quantity is


0.

42

SM5100

ERROR MESSAGE

SM5100 FATAL MESSAGE


No.

Fatal Error Message

F002 External flash memory erase error


F003 External flash memory program error
F004 External flash memory program error
F005 Internal RAM read/write error
F006 External RAM read/write error
F007 External Ethernet IC read/write error

43

SM5100

SERVER/CLIENT MANUAL

SM5100 SERVER/CLIENT MANUAL

1 Summary
SM5100 SERVER/CLIENT has three functions:
1) Floating clerk. (SPEC61)
2) Data file synchronization. (SPEC491)
3) Call PLU from server. (SPEC492)
In SERVER/CLIENT system, the maximum count of scales is 5 (1 SERVER and 4 CLIENTs).
Making all functions effective is in recommendation, and these 3 functions also can be used
independently in need.

2 SPEC
50

61

Setting of Client / Server


0

Client

Server / Workstation

Backup Server

Allow

Floating Clerk
0

194

Inhibit

Server IP Address
Enter a value between 1 to 254

208

254

For Client scale only.

Network Time Out


0

3 sec

x4

x2

x10

Enable

Auto Update of Client Off-line Report


0

Disable

Effective when SPEC61


= 1.

491

Data File Synchronization


0

492

Disable

Enable

Enable

Call PLU from Server


0

Disable

44

SM5100

SERVER/CLIENT MANUAL

3 Setting
1 Assure network settings of all scale are effective. IP-address of all scales must be set in same
subnet and different from each scale.
2SPEC141
SPEC number

SERVER

CLIENT

50

61

194

Not effective for SERVER

Port Number of SERVER

1. SPEC61,491,492 can
be set independently, but
the
settings
on
the
SERVER must be same as
the
settings
on
the
CLIENT.

SPEC135

208

Use default value

Use default value

254

491

492

NOTICE

2. SPEC254 is Effective
only when SPEC61 = 1. It
also must be set the same
value on SERVER and
CLIENT.
3. Using SPEC208 default
value
is
in
recommendation. It may
be set to other value
according to the condition
of network. If wireless
communication is used,
please dont set SPEC208
as 0. If the setting of
SPEC208 on SERVER is
different from the setting
on CLIENT, the largest
value of SPEC208 will be
used automatically.

4 Effect
When the functions are effective, the operation on SERVER is still same as stand-alone scale.
CLIENT will connect to SERVER automatically after power on. CLIENT becomes into online
status when connection is succeeded. And CLIENT will display SERVER OFF-LINE before
finishing connection. CLIENT could turn into offline status via [C] key while its displaying
SERVER OFF-LINE.
Effect on CLIENT
SPEC61
STATUS

EFFECT

SPEC491

online

offline

Reports of
CLIENT are only
stored in
SERVER.
When connection
is succeeded,
machine-setting
and tax file of
CLIENT will be
updated once by
SERVER.

Reports are
stored in
CLIENT.
If SPEC254=1,
CLIENT will
upload the
Off-line reports
to SERVER
after next
successful
connection.

online

offline

In S mode, only S4, S8


and S20 can be
operated. Rezero+230
and updating file by
PC functions are
forbidden. After
connection is
succeeded, CLIENT
will synchronize data
files from SERVER
automatically. Max
synchronization time is
5 minutes*.
(1000PLUs)

*The synchronization time shall be influenced by the counts of PLU.

45

SPEC492
online

offline

CLIENT
calls up
PLU from
SERVER
instantly.
The PLU
in CLIENT
is invalid.

CLIENT
calls up
PLU from
its own
memory.

SM 5100

FLEXIBLE BARCODE SETTING

SM-100 Flexible Barcode Setting Guide


DISPLAY
OPERATION

/lb

TARE

lb

Press [mode] third times

S1

-- -->

Press numeric 4 and 6

S46

-- -->

Press [*]
Enter numeric 1

S46.0
S46.0

Press [*]
Press [*]

PLU
FILE

F BAR
F BAR

FLEXI
BARCOD
E
0
1

NO SET
NO SET

S46.1

F BAR

FLAG

S46.2

F BAR

ITEM
CODE

REMARK
Enter programmer.
Enter Flexible Barcode
programme.

Press [*]

S46.3

F BAR

DATA1

Press [*]

S46.4

F BAR

DIGIT

Press [*]

S46.5

F BAR

SHIFT

Press [*]

S46.6

F BAR

DATA2

Program Flexible Barcode.


Program Flexible Barcode 1.
Program Flag Code.0 for F2
1 for F1F22 for non.
Enter item code length.
Enter data format for DATA1.( 0
for weight,1 for quantity,2 for unit
price.3 for weight/quantity,4 for
total price,5 for original price,6
for user programmable.)
Enter DATA1 length.
Shift for DATA1.( 0 for no right
shift,1 for right shift, 2 for right
shift x2, 3 for left shift, 4 for left
shift x2, 5 for left shift x3.
Enter data format for DATA2.( 0
for weight,1 for quantity,2 for unit
price.3 for weight/quantity,4 for
total price,5 for original price,6
for user programmable.)

DISPLAY
OPERATION

TARE

lb

/lb

Press [*]

S46.7

F BAR

DIGIT

Press [*]

S46.8

F BAR

SHIFT

Press [*]

S46.9

F BAR

Press [*]

S46.1

F BAR

Press [*]

S46.1

F BAR

Press [#]

S46

-- -->

NO
MIDDLE
CD
NO LAST
CD
ITF
BARCOD
E
FLEXI
BARCOD
E

REMARK
Enter DATA2 length.
Shift for DATA2.( 0 for no right
shift,1 for right shift, 2 for right
shift x2, 3 for left shift, 4 for left
shift x2, 5 for left shift x3.
Press [] to select the middle
check digit.
Press [] to select the last
check digit.
Press [] to swith ITF and EAN
barcode.
Save the flexible barcode 1.

Note: See the Flexible Barcode Usage Note at 3.6.1 PLU programming in SM-100 Operation manual

46

SM 5100

FLEXIBLE BARCODE SETTING

47

SM 5100

TRACEABILITY SETTING

SM-5100 Traceability Setting


Prepare
z

Set SPEC258 to 1

Traceability Programming
DISPLAY
OPERATION

/lb

TARE

lb

[Mode] [Mode] [Mode]

S1

[3] [4]

S34

[*] [1]

S34.0

[*][C][H][I][N][A]

S34.1

COUN

[#]

S34

[3] [5]

S35

[*] [1]

S35.0

HALL

[*][1]

S35.1

HALL

[*][C][U][T]

S35.2

HALL

CUT

[#]

S35

REMARK

PLU
FILE
COUNTR
Y FILE

Enter S mode

Enter country file programming

NO SET

Program country No. 1

CHINA

Name 5

Program country name CHINA

COUNTR
Y FILE
CUTTIN
G HALL

Enter cutting hall programming

NO SET

Program cutting hall No. 1

COUNTR

Program cutting hall country No.

Y
Name 3
CUTTIN
G HALL

48

Save Country No. 1

1
Program cutting hall name
CUT
Save cutting hall No. 1

SM 5100

TRACEABILITY SETTING

DISPLAY
OPERATION

/lb

REMARK

TARE

lb

[3][6]

S36

[*][1]

S36.0

HOUSE

[*][1]

S36.1

HOUSE

[*][S][L][A][U][G]

S36.2

HOUSE

SLAUG

[#]

S36

[4][7]

S47

[*][1]

S47.0

KIND

NO SET

Program kind file No. 1

[*][M][E][A][T]

S47.1

KIND

MEAT

NAME 4

Program kind name MEAT

[#]

S47

[4][8]

S48

[*][1]

S48.0

CATEG

NO SET

Program category No. 1

[*][B][E][E][F]

S48.1

CATEG

BEEF

NAME 4

Program category name BEEF

[#]

S48

SLAUGH
TER

SLAUGH
TER

HOUSE

programming

NO SET

Program slaughter house No. 1

COUNTR

Program slaughter house

Y
NAME 5

HOUSE
KIND
FLIE

KIND
FILE
CATEGO
RY FILE

CATEGO
RY FILE

49

Enter slaughter house

country No.1
Program slaughter house name
SLAUG
Save slaughter house No. 1

Enter kind file programming

Save kind file No. 1

Enter category file programming

Save category file No. 1

SM 5100

TRACEABILITY SETTING

DISPLAY
OPERATION

/lb

REMARK

TARE

lb

[4][9]

S49

[*][1]

S49.0

BREED

NO SET

Program breed file No. 1

[*][B][U][L][L]

S49.1

BREED

BULL

NAME 4

Program breed name BULL

[#]

S49

[3][7]

S37

[*][1]

S37.0

TRACE

NO SET

Program traceability No. 1

[*][1]

S37.1

TRACE

BORN

Choose born country No. 1

[*][1]

S37.2

TRACE

FATTEN

Choose fatten country No. 1

[*][1]

S 37.3

TRACE

[*][1]

S37.4

S CNT

LNK 1

[*][1]

S37.5

TRACE

C HALL

[*][1]

S37.6

C CNT

LNK 1

[*][1]

S37.7

TRACE

ORIGIN

BREED
FILE

BREED
FILE
TRACEA
BILITY

50

S
HOUSE

Enter breed file programming

Save breed file No. 1

Enter traceability programming

Choose slaughter house No. 1


Choose link country No. 1 for
slaughter house
Choose cutting house No. 1
Choose link country No. 1 for
cutting hall
Choose original country No. 1

SM 5100

TRACEABILITY SETTING

DISPLAY
OPERATION

REMARK

TARE

lb

/lb

[*][R][C][D]

S37.8

R-CD

RCD

NAME 3

Program R-CD content RCD

[*][G][T][I][N]

S37.9

GTIN

GTIN

NAME 4

Program GTIN content GTIN

[*][L][O][T]

S37.10

LOT

LOT

NAME 3

Program LOT content LOT

[*][1]

S37.11

TRACE

KIND

[*][1]

S37.12

TRACE

CATEG

Choose category No. 1

[*][1]

S37.13

TRACE

BREED

Choose breed No. 1

[*][C][O][N][T]

S37.14

CONT

CONT

NAME 4

Program cont content CONT

[*][0][6][0][3][1][0]

S37.15

TRACE

060310

EAT D

Program eat by date 06/03/10

[*][5][0][0][0]

S37.16

TRACE

5.000

WEGHT

Program maximum weight 5kg

[*][S][C][D]

S37.17

S CD

SCD

NAME 3

Program S CD content SCD

[*][S][N][M]

S37.18

S NM

SNM

NAME 3

Program S NM content SNM

[*][S][A][D][1]

S37.19

S AD1

SAD1

NAME 4

Program S AD1 content SAD1

[*][S][A][D][2]

S37.20

S AD2

SAD2

NAME 4

Program S AD2 content SAD2

[#]

S37

TRACEA
BILITY

Choose kind No. 1

Save traceability No. 1

Free Format Programming


z
z

Enter S12 FREE FORMAT, press [*]


Edit the correlative items for traceability in free format

PLU ITEM Programming


z
z

Enter S19 PLU ITEM, press [*]


Set Item TRACE to PROGRAM and press [#] to save

PLU Programming
z
z
z

When you edit PLU, set S1.64 PLU to TRACE ALLOW and press [*]
Input traceability number and press [#] to save
In the end, when you call the PLU and print label, youll see the traceability information on the label

51

SM 5100

Nutrition Fact Setting

SM-5100 Nutrition Fact Setting


Concept
Nutrition uses fix template to print. Totally It has 12 fix templates(No. 70 ~ No. 81).

Setting Method
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.

Enter S mode
Enter S19 --- PLU ITEM and set IMAGE and NUTRI to PROGRAM
Enter S12 --- FREE FORMAT
Enter S12.5 IMG 1 47 F ITEM to S12.5 IMG 10 56 F ITEM to set the print area of Nutrition. (In
each label format, totally you can print 10 images)
Enter S1 --- PLU FILE to create PLU.
Enter S1.50 PLU 0 IMAGE 1 to choose the template number for IMAGE 1 (From No. 70~ No. 81).

Enter S1.59 PLU 0 IMAGE 10 to choose the template number for IMAGE 10 (From No. 70~ NO. 81).
Set S1.81 PLU PRINT NUTRI to set nutrition print status to Print.
Enter from S1.82 to S1.10 to input nutrition contents.
For extra details on the Nutrition Fact, Enter S11: TXT form to edit by hands.
Enter S12 --- FREE FORMAT to set up the TXT position.
Press [PLU] key to save.

52

SM 5100

PC-FL1 OPERATION

PC-FL1 OPERATION
Note: this guide is available just for SM series expect the SM-5100.
1. The link of the hardware
Link the PC with scale via RS232C.

2. Operation
1. The Spec setting in the scale
3 for SPEC51 (The SIO baud rate is 9600. )
1 for SPEC52 (The SIO data length is 8.)
0 for SPEC53 (No SIO parity digit.)
0 for SPEC54 (1 bit stop bit.)
2 for SPEC60 (SIO work via PCFL-1)
2. The setting in the software
1) open the software
2) the com port setting

53

SM 5100

PC-FL1 OPERATION

Please note:
a) The com port should be the same as the one used in your computer.
b) The com port setting must be same as setting in the scale.
3) the folder for save

54

SM 5100

PC-FL1 OPERATION

Note: You could set the default folder for save the data received from the scale.
3.

Operation

1)

receive the data from the scale

55

SM 5100

PC-FL1 OPERATION

Note: You could press the key to receive the data from scale.
2) send the data to scale

Note: You could press the key to send the data to scale.
1) the operation in the scale
DISPLAY
OPERATION
TARE

[zero]+[0][1][0]
Preset key [8]
Preset key [8]
Preset key [8]

DAIL
Y
BAC
BAC
BAC
BAC

[*]

BAC

Preset key [8]

BAC

Preset key [8]

BAC

[M][0][M][M]

[*]
[Tare]

TOUT
DAIL
Y

REMARK

lb

/lb

CLR

PLU
FOR
OTH
ALL
SA
TO
RD
FR
COM
P

FILE
FILE
FILE
FILE

X
X
X
X

FL-1

FL-1

FL-1

OPN

GOOD

Press preset key [7]or [8] to


select the transmit method:
save data to FL-1,read
data from FL-1,verify data
with FL-1.
Transmit successfully.

CLR

Back to Z mode.

56

Enter the [Z] mode

Press preset key [7]or [8] to


select the transmit item:
PLU, Format, Others or All.

Das könnte Ihnen auch gefallen