Sie sind auf Seite 1von 16

Quick Guide

Insulation for the LNG, Petrochemical and Process Industries

Prestige Projects
Project:
Dahbol LNG India
Engineer: Kvanerner
Insulation Contractor:
Punj Lloyd
Product:
Tarecpir 45 kg/m3 / 2.8 lb/ft3
Volume:
10,000 m3 / 35,4146 ft3

Project:
Puerto Rico LNG
Engineer: PDM
Insulation Contractor:
Insulations Inc
Product:
Tarecpir 35 kg/m3 / 2.2 lb/ft3

Insulation Benefits
Description
The Tarecpir range of CFC/HCFCfree rigid
polyisocyanurate (PIR) insulation is suitable for a wide
spectrum of applications. Whilst retaining all of the benefits
of rigid polyurethane insulation, Tarecpir has a considerably
increased resistance to burning and spread of flame.
The Tarecpir insulation range consists of:
l Tarecpir M1 (improved fire performance);
l Tarecpir B2 (improved thermal efficiency);
l Tarecpir CR (cryogenic applications);
l Tarecpir HT (high temperature); and
l Tarecpir HD (high density).

Tarecpir has been developed to provide optimum


performance with regards to insulation efficiency, fire
resistance, compressive strength, environment, health,
safety and cost.
Tarecpir has, over time, gained worldwide recognition
in many industries including Building Services / HVAC,
industrial process, petrochemical, cryogenic and LNG for
outstanding product quality and performance.

Structure
Tarecpir has a high closed cell content and consists of a
densely cross linked matrix which does not readily break
down in service.

Temperature Range
Tarecpir may be used for pipework and equipment
operating within the temperature range 200C to
+120C / 328F to +248F, and even up to +200C /
+392F for Tarecpir HT.

Thermal Performance
Tarecpir is one of the most thermally efficient insulation
materials commonly available. It retains its thermal
performance under the most severe operating conditions
by virtue of its closed cell structure and high resistance to
moisture absorption.
Tarecpir has a thermal conductivity as low as
0.024 W/mK / 0.166 Btuin/hrft2F.
A low thermal conductivity allows specified thermal
performance standards to be achieved with a minimal
thickness of insulation. This is particularly significant
where space saving is important.
A thinner insulant can facilitate installation in confined
spaces. Furthermore, it can often result in a lower surface
area and therefore savings in finishing materials.

Insulation Benefits
Moisture Resistance

Tarec pir has a 95% (or greater) closed cell content,


which makes it nonwicking and highly resistant to
moisture penetration. This is particularly valuable in
humid conditions where the build up of moisture
can compromise the performance of lesser insulation
materials. It is an ideal insulation material for cold, chilled
and low temperature hot water pipework.
When used in conjunction with a vapour tight facing,
Tarecpir provides a system which is totally moisture resistant.

Chemical Resistance &


Compatibility
Tarecpir is resistant to a wide range of oils, solvents
and chemicals. Its compatibility with most solvent based
coatings and adhesives, and polyester and epoxy resin
based coatings, allows it to maintain its physical integrity
when in contact with such substances.

Quality Assurance
The Tarecpir range is manufactured to the highest quality
standards under a quality control system approved to
EN ISO 9001: 2000.

Hygiene
Tarecpir is resistant to fungus and mould growth, will
not sustain vermin and is nonfibrous, odourless and
nontainting.

Fire Performance
Tarecpir is a thermoset material. When subjected to fire,
its outer surface forms a strong carbonaceous layer that
retards further flame spread and penetration. Unlike
thermoplastic materials, Tarecpir does not melt or produce
flaming droplets when exposed to fire. Tarecpir satisfies
the requirements of major industrial specifications.

Insulation Benefits
Tarecpir M1 Insulation
Tarecpir M1 (improved fire performance) has been
specially developed for industrial process and building
services / HVAC applications where superior fire
performance is required. Tarecpir M1 is classified as being
Class 0 by the Building Regulations in England & Wales,
Northern Ireland and the Republic of Ireland, and Low Risk
by the Building Standards in Scotland. It also achieves a
Flame Spread Index of < 35* under ASTM E 84.

Tarecpir CR Insulation
For cryogenic applications where excellent fire
performance, enhanced compressive strength and
resistance to thermal stress are required, Tarecpir CR
(cryogenic applications) has been developed.
Its fire performance (Class 0 to the Building Regulations
in England & Wales, Northern Ireland and the Republic
of Ireland, and Low Risk to the Building Standards in
Scotland, plus a Flame Spread Index of < 25 under ASTM
E 84), and its resistance to thermal stress makes Tarecpir
CR ideal for insulation applications with a working
temperature as low as 200C / 328F.

Tarecpir B2 Insulation
Tarecpir B2 (improved thermal efficiency) is recommended
for building services where increased thermal efficiency is
priority. Tarecpir B2 has a thermal conductivity of 0.026
W/mK / 0.166 Btuin/hrft2F.

* Tarecpir M1 40 kg/m3

Insulation Benefits
Applications
Tarecpir is a versatile insulation material with a high
strength to density ratio. It is lightweight, easy to
transport, handle and install. Tarecpir is specified for use
in a wide range of applications including:
l industrial process, food, beverage, brewery,

pharmaceutical and chemical plants;


l cryogenic, LNG, LPG, petrochemical, ethylene and

ammonia production; and


l Building Services / HVAC applications.

In particular, Tarecpir satisfies the strict requirements of


major petrochemical and LNG specifications. As a result,
Tarecpir is synonymous with specifications for high quality
thermal insulation worldwide.

Tarecpir HD Insulation
Tarecpir HD (high density) is a specially modified rigid
polyisocyanurate insulation available in a range of
densities up to 320 kg/m3 / 20 lb/ft3. Tarecpir HD is
particularly suitable for use in load bearing applications,
making it ideal for insulated pipe support inserts.
The use of Tarecpir HD for insulated pipe support inserts
can help to avoid the potential problems of cold bridging
and / or energy loss between the pipework and support
structure.

Tarecpir HT Insulation
Tarecpir HT (high temperature) is a specially modified
rigid polyisocyanurate insulation with a standard density
of 40 kg/m3 / 2.5 lb/ft3. Other densities are available
upon request. Due to its special formulation, Tarecpir
HT is capable of dealing with a continuous working
temperature of +200C / +392F.
When Tarecpir HT is used at high temperatures, the
insulation maintains its closed cell content and its
dimensional stability throughout its in service life.
Tarecpir HT has been used on many high demanding
projects worldwide.

Availability
Tarecpir is available in the following forms as standard:
l pipe sections and bends;
l insulated pipe support inserts;
l radiused and bevelled segments;
l standard slab: 2500 mm x 1000 mm / 98.4 in x 39.3 in

& 2500 mm x 1250 mm / 98.4 in x 49.2 in;


l standard and non standard pipe sizes; and
l single layer, multi layer or rebated joints.

Technical Data
Tarecpir HT Rigid Polyisocyanurate Insulation 40 kg/m3 / 2.5 lb/ft3
General Physical Properties (Metric)
Property

Test Method

Unit

Typical Value

Nominal Density
(EN ISO 845) / (ASTM D 1622)
kg/m3 40
Thermal Conductivity at +10C (EN 12667) / (ASTM C 518)
W/mK
0,026
Colour
Gris
Closed Cell Content
(EN ISO 4590) Methode 1 /

(ASTM D 2856) Methode B
%
95
Operating Temperature Limits Limite maximale
C
+200

Limite minimale
C
180
Minimum Compressive
(EN 826) / (ASTM D 1621)
Strength at +23C
Parallel
kPa
230

Perpendicular
kPa
150
Minimum Tensile
(ASTM D 1623)
Strength at +23C
Parallel
kPa
490

Perpendicular
kPa
340
Linear Dimensional Stability (EN 1604) / (ASTM D 2126)

+93C bij 24 hours
%
1

30C bij 24 hours
%
1

+70C bij 24 hours and 95% RH
%
3
Friability for 10 mins
(ASTM C 421)
%
< 40
Linear Expansion Coefficient (ASTM D 696)
m/mK
4070 x 106
Water Absorption
(ISO 2896)
Vol %
5,5
Water Vapour Permeability
(ASTM E 96)
ng/Pa.s.m
5,5

General Physical Properties (Imperial)


Property

Test Method

Unit

Nominal Density
(EN ISO 845) / (ASTM D 1622)
lb/ft
Thermal Conductivity at +50F (EN 12667) / (ASTM C 518)
Btuin/hrft2F
Colour
Closed Cell Content
(EN ISO 4590) Method 1 /

(ASTM D 2856) Method B
%
Operating Temperature Limits Upper Limit
F

Lower Limit
F
Minimum Compressive
(EN 826) / (ASTM D 1621)
Strength at +73F
Parallel
psi

Perpendicular
psi
Minimum Tensile
(ASTM D 1623)
Strength at +73F
Parallel
psi

Perpendicular
psi
Linear Dimensional Stability (EN 1604) / (ASTM D 2126)

+199.4F for 24 hours
%

22F for 24 hours
%

+158F for 48 hours and 95% RH
%
Friability for 10 mins
(ASTM C 421)
%
Linear Expansion Coefficient (ASTM D 696)
ft/ftK
Water Absorption
(ISO 2896)
Vol %
Water Vapour Permeability (ASTM E 96)
Perm inch
3

Typical Value
2.5
0.18
Grey
95
+392
292
33.4
21.8
71.0
49.3
1
1
3
< 40
4070 x 106
5.0
3.8

Fire Test Classifications


Property

Test Method

Typical Value

Epiradiateur

NF P 92501

M4

Property

Test Method

Typical Value

Vertical Burning

DIN 41021: 1998

B2

Fire Test Specifications

Technical Data
Tarecpir M1 Rigid Polyisocyanurate Insulation 33-80 kg/m3 / 2.1-5.0 lb/ft3
General Physical Properties (Metric)
Property

Test Method

Unit

Typical Value

33 40 50 80
Nominal Density
(EN ISO 845) / (ASTM D 1622)
kg/m3
Thermal Conductivity at +10C (EN 12667) / (ASTM C 518)
W/mK
0.026
0.026
0.026
0.029

Colour Green Green Green Green
Closed Cell Content
(EN ISO 4590) Method 1 /

(ASTM D 2856) Method B
%
95
95
95
95
Operating Temperature Limits Upper Limit
C
+120
+120
+120
+120

Lower Limit
C 200 200 200 200
Minimum Compressive
(EN 826) / (ASTM D 1621)

Strength at +23C Parallel
kPa 180 220 310 700

Perpendicular
kPa 90 140 200 520
Minimum Tensile
(ASTM D 1623)

Strength at +23C Parallel
kPa 350 410 510 850

Perpendicular
kPa 190 300 350 700
Linear Dimensional Stability (EN 1604) / (ASTM D 2126)

+93C for 24 hours
%
1
1
1
1

30C for 24 hours
%
1
1
1
1

+70C for 48 hours and 95% RH
%
3
3
3
3
Friability for 10 mins
(ASTM C 421)
%
< 40
< 35
< 35
< 20
Linear Expansion Coefficient (ASTM D 696)
m/mK
4070 x 106 4070 x 106 4070 x 106 4070 x 106
Water Absorption
(ISO 2896)
Vol %
5.0
5.0
5.0
5.0
Water Vapour Permeability
(ASTM E 96)
ng/Pa.s.m
5.5
5.5
5.5
5.5

General Physical Properties (Imperial)


Property

Test Method

Unit

Typical Value

2.1 2.5 3.1 5.0


Nominal Density
(EN ISO 845) / (ASTM D 1622)
lb/ft
Thermal Conductivity at +50F (EN 12667) / (ASTM C 518)
Btuin/hrft2F
0.18 0.18 0.18 0.20

Colour Green Green Green Green
Closed Cell Content
(EN ISO 4590) Method 1 /

(ASTM D 2856) Method B
%
95
95
95
95
Operating Temperature Limits Upper Limit
F
+248
+248
+248
+248

Lower Limit
F 328 328 328 328
Minimum Compressive
(EN 826) / (ASTM D 1621)
Strength at +73F
Parallel
psi
26
32
45
102

Perpendicular
psi 13 20 29 75
Minimum Tensile
(ASTM D 1623)
Strength at +73F
Parallel
psi
51
60
74
123

Perpendicular
psi 28 44 51 102
Linear Dimensional Stability (EN 1604) / (ASTM D 2126)

+199.4F for 24 hours
%
1
1
1
1

22F for 24 hours
%
1
1
1
1

+158F for 48 hours and 95% RH
%
3
3
3
3
Friability for 10 mins
(ASTM C 421)
%
< 40
< 35
< 35
< 20
Linear Expansion Coefficient (ASTM D 696)
ft/ftK
4070 x 106 4070 x 106 4070 x 106 4070 x 106
Water Absorption
(ISO 2896)
Vol %
5.0
5.0
5.0
5.0
Water Vapour Permeability
(ASTM E 96)
Perm inch
3.8
3.8
3.8
3.8
3

Fire Test Classifications


Fire Test

Test Method

Fire Propagation
BS 4766: 1989

Surface Spread of Flame
BS 4767: 1997
Horizontal Burning
EN ISO 3582: 2000
Oxygen Index
EN ISO 45892: 1996
Temperature Index
EN ISO 45893: 1996
Flame Spread Index
ASTM E 84
Fire Propagation
NEN 6065
Smoke Index
NEN 6066

Typical Result
Index of performance (I) not exceeding 12 and sub index (i1)
not exceeding 6*
Class 1*
Class 1*
Class 1*
Class 1*
25 mm / 1 in
25 mm / 1 in
25 mm / 1 in
25 mm / 1 in
30%
30%
30%
30%
> 390C / 734F > 390C / 734F > 390C / 734F > 390C / 734F
30
25
25

Class 2

1.5** / 2.2***

* These test results combined enables a Class 0 classification to the Building Regulations in England & Wales, Northern Ireland and the Republic of Ireland, and a Low Risk
classification to the Building Standards in Scotland. These tests were conducted on samples of 25 mm / 1 in thickness faced with a reinforced aluminium foil vapour barrier jacket.
** Faced with a glass reinforced aluminium foil vapour barrier jacket.
*** Faced with a multiple layered polyester and aluminium foil vapour barrier jacket.

Fire Test Specifications


Fire Test

Test Method


Epiradiateur NF P 92501
Vertical Burning
DIN 41021: 1998

Specification
M1 M1 M1 M1
B2
B2
B2
B2

Technical Data
Tarecpir B2 Rigid Polyisocyanurate Insulation 33-60 kg/m3 / 2.1-3.75 lb/ft3
General Physical Properties (Metric)
Property

Test Method

Unit

Typical Value

33 40 60
Nominal Density
(EN ISO 845) / (ASTM D 1622)
kg/m3
Thermal Conductivity at +10C (EN 12667) / (ASTM C 518)
W/mK
0.026
0.026
0.028

Colour Cream Cream Cream
Closed Cell Content
(EN ISO 4590) Method 1 /

(ASTM D 2856) Method B
%
95
95
95
Operating Temperature Limits
Upper Limit
C
+120
+120
+120

Lower Limit
C 180 180 180
Minimum Compressive
(EN 826) / (ASTM D 1621)
Strength at +23C
Parallel
kPa
180
250
430

Perpendicular
kPa
90
150
230
Minimum Tensile
(ASTM D 1623)
Strength at +23C
Parallel
kPa
350
450
690

Perpendicular
kPa 250 350 530
Linear Dimensional Stability
(EN 1604) / (ASTM D 2126)

+93C for 24 hours
%
1
1
1

30C for 24 hours
%
1
1
1

+70C for 48 hours and 95% RH
%
3
3
3
Friability for 10 mins
(ASTM C 421)
%
< 30
< 30
< 30
Linear Expansion Coefficient
(ASTM D 696)
m/mK
4070 x 106 4070 x 106 4070 x 106
Water Absorption
(ISO 2896)
Vol %
5.0
5.0
5.0
Water Vapour Permeability
(ASTM E 96)
ng/Pa.s.m
5.5
5.5
5.5

General Physical Properties (Imperial)


Property

Test Method

Unit

Typical Value

2.1 2.5 3.75


Nominal Density
(EN ISO 845) /(ASTM D 1622)
lb/ft
Thermal Conductivity at +50F (EN 12667) / (ASTM C 518)
Btuin/hrft2F
0.180 0.180 0.194

Colour Cream Cream Cream
Closed Cell Content
(EN ISO 4590) Method 1 /

(ASTM D 2856) Method B
%
95
95
95
Operating Temperature Limits
Upper Limit
F
+248
+248
+248

Lower Limit
F 292 292 292
Minimum Compressive
(EN 826) / (ASTM D 1621)
Strength at +73F
Parallel
psi
26
36
62

Perpendicular
psi 13 22 33
Minimum Tensile
(ASTM D 1623)
Strength at +73F
Parallel
psi
51
65
100

Perpendicular
psi 36 51 77
Linear Dimensional Stability
(EN 1604) / (ASTM D 2126)

+199.4F for 24 hours
%
1
1
1

22F for 24 hours
%
1
1
1

+158F for 48 hours and 95% RH
%
3
3
3
Friability for 10 mins
(ASTM C 421)
%
< 30
< 30
< 30
Linear Expansion Coefficient
(ASTM D 696)
ft/ftK
4070 x 106 4070 x 106 4070 x 106
Water Absorption
(ISO 2896)
Vol %
5.0
5.0
5.0
Water Vapour Permeability
(ASTM E 96)
Perm inch
3.8
3.8
3.8
3

10

Fire Test Classifications


Fire Test

Test Method

Horizontal Burning
EN ISO 3582: 2000
Temperature Index
EN ISO 45893: 1996

Brandkennziffer

Typical Result

125 mm / 5 in
125 mm / 5 in
125 mm / 5 in
> 390C / 734F
> 390C / 734F
> 390C / 734F
5.3 5.3 5.3

Fire Test Specifications


Fire Test

Test Method

Vertical Burning

DIN 41021: 1998

B2

Specification
B2

B2

11

Technical Data
Tarecpir CR Rigid Polyisocyanurate Insulation 42-50 kg/m3 / 2.6-3.1 lb/ft3
General Physical Properties (Metric)
Property

Test Method

Unit

Typical Value

42 45 48 50
Nominal Density
(EN ISO 845) / (ASTM D 1622)
kg/m3
Thermal Conductivity at +10C (EN 12667) / (ASTM C 518)
W/mK
0.025
0.026
0.026
0.026

Colour Green Green Green Green
Closed Cell Content
(EN ISO 4590) Method 1 /

(ASTM D 2856) Method B
%
95
95
95
95
Operating Temperature Limits Upper Limit
C
+120
+120
+120
+120

Lower Limit
C 200 200 200 200
Minimum Compressive
(EN 826) / (ASTM D 1621)

Strength at +23C Parallel
kPa 260 310 320 340

Perpendicular
kPa 180 200 220 230
Minimum Tensile
(ASTM D 1623)

Strength at +23C Parallel
kPa 430 490 500 510

Perpendicular
kPa 330 380 390 400
Linear Dimensional Stability (EN 1604) / (ASTM D 2126)

+93C for 24 hours
%
1
1
1
1

30C for 24 hours
%
1
1
1
1

+70C for 48 hours and 95% RH
%
3
3
3
3
Friability for 10 mins
(ASTM C 421)
%
< 30
< 30
< 30
< 25
Linear Expansion Coefficient (ASTM D 696)
m/mK
4070 x 106 4070 x 106 4070 x 106 4070 x 106
Water Absorption
(ISO 2896)
Vol %
5.0
5.0
5.0
5.0
Water Vapour Permeability
(ASTM E 96)
ng/Pa.s.m
5.5
5.5
5.5
5.5

General Physical Properties (Imperial)


Property

Test Method

Unit

Typical Value

Nominal Density
(EN ISO 845) / (ASTM D 1622)
lb/ft 2.6 2.8 3.0 3.1
Thermal Conductivity at +50F (EN 12667) / (ASTM C 518)
Btuin/hrft2F
0.17 0.18 0.18 0.18

Colour Green Green Green Green
Closed Cell Content
(EN ISO 4590) Method 1 /

(ASTM D 2856) Method B
%
95
95
95
95
Operating Temperature Limits Upper Limit
F
+248
+248
+248
+248

Lower Limit
F 328 328 328 328
Minimum Compressive
(EN 826) / (ASTM D 1621)

Strength at +73F Parallel
psi 38 45 46 49

Perpendicular
psi 26 29 21 33
Minimum Tensile
(ASTM D 1623)

Strength at +73F Parallel
psi 62 71 73 74

Perpendicular
psi 48 55 57 58
Linear Dimensional Stability (EN 1604) / (ASTM D 2126)

+199.4F for 24 hours
%
1
1
1
1

22F for 24 hours
%
1
1
1
1

+158F for 48 hours and 95% RH
%
3
3
3
3
Friability for 10 mins
(ASTM C 421)
%
< 30
< 30
< 30
< 25
Linear Expansion Coefficient (ASTM D 696)
ft/ftK
4070 x 106 4070 x 106 4070 x 106 4070 x 106
Water Absorption
(ISO 2896)
Vol %
5.0
5.0
5.0
5.0
Water Vapour Permeability
(ASTM E 96)
Perm inch
3.8
3.8
3.8
3.8
3

12

Fire Test Classifications


Fire Test

Test Method

Fire Propagation
BS 4766: 1989

Surface Spread of Flame
BS 4767: 1997
Horizontal Burning
EN ISO 3582: 2000
Oxygen Index
EN ISO 45892: 1996
Temperature Index
EN ISO 45893: 1996

Typical Result
Index of performance (I) not exceeding 12 and sub index (i1)
not exceeding 6*
Class 1*
Class 1*
Class 1*
Class 1*
10 mm / 0.4 in 10 mm / 0.4 in 10 mm / 0.4 in 10 mm / 0.4 in
30%
30%
30%
30%
> 390C / 734F > 390C / 734F > 390C / 734F > 390C / 734F

* These test results combined enables a Class 0 classification to the Building Regulations in England & Wales, Northern Ireland and the Republic of Ireland, and a Low Risk
classification to the Building Standards in Scotland. These tests were conducted on samples of 25 mm / 1 in thickness faced with a reinforced aluminium foil vapour barrier jacket.

Fire Test Specifications


Fire Test

Test Method

Flame Spread Index


ASTM E 84

Epiradiateur NF P 92501
Vertical Burning
DIN 41021: 1998

Specification
< 25*
< 25*
< 25*
< 25*
M1 M1 M1 M1
B2
B2
B2
B2

* These tests were conducted on samples of 25 mm / 1 in thickness faced with an aluminium foil vapour barrier jacket.

13

Technical Data
Tarecpir HD Rigid Polyisocyanurate Insulation 120-320 kg/m3 / 7.5-20.0 lb/ft3
General Physical Properties (Metric)
Property

Test Method

Unit

Typical Value

Nominal Density
(EN ISO 845) / (ASTM D 1622)
kg/m3 120 160 224 320
Thermal Conductivity at +10C (EN 12667) / (ASTM C 518)
W/mK
0.033
0.036
0.038
0.048

Colour Green Green Green Green
Closed Cell Content
(EN ISO 4590) Method 1 /

(ASTM D 2856) Method B
%
95
95
95
95
Operating Temperature Limits Upper Limit
C
+120
+120
+120
+120

Lower Limit
C 200 200 200 200
Minimum Compressive
(EN 826) / (ASTM D 1621)

Strength
Parallel at +23C
kPa 1200 1900 2950 5750

Parallel at 165C
kPa

4600
9250
18750

Perpendicular at +23C
kPa 1000 1650 2750 5000
Minimum Tensile
(ASTM D 1623)

Strength
Parallel at +23C
kPa 1400 1750 3000 4900

Parallel at 165C
kPa

1950
3400
5400

Perpendicular at +23C
kPa 1300 1550 2800 4700
Linear Dimensional Stability (EN 1604) / (ASTM D 2126)

+93C for 24 hours
%
1
1
1
1

30C for 24 hours
%
1
1
1
1

+70C for 48 hours and 95% RH
%
3
3
3
3
Friability for 10 mins
(ASTM C 421)
%
< 10
< 10
< 5
<5
Linear Expansion Coefficient (ASTM D 696)
m/mK
4070 x 106 4070 x 106 4070 x 106 4070 x 106
Water Absorption
(ISO 2896)
Vol %
5.0
5.0
5.0
5.0
Water Vapour Permeability
(ASTM E 96)
ng/Pa.s.m
5.5
5.5
5.5
5.5

General Physical Properties (Imperial)


Property

Test Method

Unit

Typical Value

Nominal Density
(EN ISO 845) / (ASTM D 1622)
lb/ft 7.5 10.0 14.0 20.0
Thermal Conductivity at +50F (EN 12667) / (ASTM C 518)
Btuin/hrft2F
0.23 0.25 0.26 0.33

Colour Green Green Green Green
Closed Cell Content
(EN ISO 4590) Method 1 /

(ASTM D 2856) Method B
%
95
95
95
95
Operating Temperature Limits Upper Limit
F
+248
+248
+248
+248

Lower Limit
F 328 328 328 328
Minimum Compressive
(EN 826) / (ASTM D 1621)

Strength
Parallel at +73F
psi 174 276 428 834

Parallel at 265F
psi
667 1342 2720

Perpendicular at +73F
psi
145 240 399 725
Minimum Tensile
(ASTM D 1623)

Strength
Parallel at +73F
psi 203 254 435 711

Parallel at 265F
psi

283
493
783

Perpendicular at +73F
psi 189 225 406 682
Linear Dimensional Stability (EN 1604) / (ASTM D 2126)

+199.4F for 24 hours
%
1
1
1
1

22F for 24 hours
%
1
1
1
1

+158F for 48 hours and 95% RH
%
3
3
3
3
Friability for 10 mins
(ASTM C 421)
%
< 10
< 10
< 5
<5
Linear Expansion Coefficient (ASTM D 696)
ft/ftK
4070 x 106 4070 x 106 4070 x 106 4070 x 106
Water Absorption
(ISO 2896)
Vol %
5.0
5.0
5.0
5.0
Water Vapour Permeability
(ASTM E 96)
Perm inch
3.8
3.8
3.8
3.8
3

14

Fire Test Classifications


Fire Test

Test Method

Horizontal Burning
EN ISO 3582: 2000
Temperature Index
EN ISO 45893: 1996

Epiradiateur NF P 92501

Typical Result
20 mm / 0.8 in 20 mm / 0.8 in 20 mm / 0.8 in 20 mm / 0.8 in
> 390C / 734F > 390C / 734F > 390C / 734F > 390C / 734F
M4 M4 M4 M4

Fire Test Specifications


Fire Test

Test Method

Vertical Burning

DIN 41021: 1998

Specification
B2

B2

B2

B2

15

UK, Ireland & Gibraltar


Kingspan Industrial Insulation Ltd
Pembridge, Leominster, Herefordshire, HR6 9LA, United Kingdom
General Enquiries Tel: +44 (0) 1544 388 601
Technical Advice Tel: 0808 168 7363 or +44 (0) 1457 890534

Australasia, Oceania and SE Asia as far west and north as,


and including, Myanmar, China, Mongolia, Japan
Kingspan Insulation Pty Ltd
266 Beringarra Ave, Malaga, WA 6090, Australia
Tel: 1300 247 235 (for calls within Australia only)
Tel: +61 8 6240 6200 (for calls outside of Australia)

The rest of Europe (excluding Turkey, Malta & Cyprus)


and Russia
Kingspan Insulation N.V.
Visbeekstraat 24
B 2300 Turnhout, Belgium
Tel: +32 14 44 25 25

Canada, USA, Bermuda, the Cayman Islands, Puerto Rico


& St Pierre and Miquelon
Kingspan Insulation LLC
2100 Riveredge Parkway, Suite 175, Atlanta, Georgia, 30328, USA
Tel: 1 800 227 7339 (for calls within USA only)
Tel: +1 (678) 589 7300 (for calls outside of USA)

All other countries


PAL Middle East PIR LLC
P.O. Box 113826, Dubai Investment Park 2, Dubai, U.A.E.
Tel: +971 4 889 1000

www.kingspaninsulation.com
TM

Kingspan, Tarec and the Lion Device are Trademarks of the Kingspan Group plc.

Kingspan reserves the right to amend product specifications without prior notice. All information, technical details and fixing instructions etc. included in this literature are given in good faith
and apply to uses described. Recommendations for use should be verified as to the suitability and compliance with actual requirements, specifications and any applicable laws and regulations.
For other applications or conditions of use, Kingspan offers a free Technical Advisory Service the advice of which should be sought for uses of Kingspan products that are not specifically
described herein. Please check that your copy of the literature is current by contacting the Marketing Department.
Published June 2015

Das könnte Ihnen auch gefallen