Beruflich Dokumente
Kultur Dokumente
TCNICO
1 Edicin
Tabla de contenido
A INFORMACIN GENERAL
A.1
A.2
A.3
A.4
A.5
A.6
A.7
PRESENTACIN
...........................................................................
LA EMPRESA
...........................................................................
LA MULTINACIONAL ...........................................................................
SISTEMA DE GESTIN...........................................................................
CMO UTILIZAR ESTE MANUAL ......................................................
HISTORIA DE LOS SISTEMAS CONSTRUCTIVOS EN SECO...................
DEFINICIN DEL SISTEMA CONSTRUCTIVO EN SECO ETERNIT.........
A.7.1 Ventajas del Sistema Constructivo en Seco ETERNIT ......................
A.7.2 Caratersticas del Sistema Constructivo
.................................
6
6
7
8
9
10
11
11
12
14
15
15
15
16
17
17
19
19
19
20
20
21
22
22
23
23
23
23
24
24
24
25
25
SOLUCIONES CONSTRUCTIVAS
C.1 MUROS SECOS (TABIQUES) ................................................................
C.1.1 Caractersticas estructurales
......................................................
C.1.2 Componentes ...........................................................................
C.1.2.1 El bastidor ................................................................
C.1.2.2 Placas planas de emplacado (FC) ................................
C.1.2.3 Tornillos y fijaciones ......................................................
C.1.2.4 Cintas, sellos y masillas
...........................................
C.1.3. Tipos de muros secos ................................................................
C.1.3.1 Muro simple de una cara
...........................................
C.1.3.2 Muro simple de dos caras ...........................................
C.1.3.3 Muro simple especializado ...........................................
C.1.3.4 Muros adosados
......................................................
C.1.3.5 Muros de gran altura ......................................................
C.1.3.6 Muros curvos ................................................................
C.1.3.7 Muros en ngulo
......................................................
C.1.4 Aislamientos
...........................................................................
.................................................................
C.1.4.1 Trmicos
C.1.4.2 Acsticos
.................................................................
C.1.4.3 Humedad y vapor .......................................................
C.1.5 Proceso constructivo .................................................................
C.1.5.1 Descripcin del proceso
............................................
C.1.5.2 Materiales de acabado
............................................
C.1.6 Detalles constructivos .................................................................
C.1.7 Gua de diseo y clculo
.......................................................
C.1.8 Gua de clculo, muros y fachadas
............................................
C.2 FACHADAS Y CERRAMIENTOS
.......................................................
C.2.1 Caractersticas estructurales
.......................................................
C.2.2 Componentes ............................................................................
C.2.2.1 Perfiles metlicos de bastidores para fachadas
.............
C.2.2.2 Placas planas ETERBOARD .............................................
C.2.2.3 Anclajes y fijaciones .......................................................
C.2.3 Tipos de fachadas secas
.......................................................
C.2.3.1 Fachada confinada .......................................................
C.2.3.2 Colgante, flotante o de cortina
..................................
C.2.3.3 Recubrimientos
.......................................................
C.2.4 Tratamiento de juntas ..................................................................
C.2.5 Acabados de fachadas ..................................................................
C.3 ENTREPISOS .......................................................................................
C.3.1 Caractersticas estructurales
........................................................
C.3.2 Componentes .............................................................................
C.3.2.1 Placas planas ETERBOARD .............................................
C.3.2.2 Bastidores en perfiles metlicos
...................................
C.3.2.3 Anclajes y fijaciones ........................................................
C.3.2.4 Cintas masillas y sellos
.............................................
C.3.3 Sistemas de entrepiso ...................................................................
C.3.3.1 Sistema lineal ...................................................................
C.3.3.2 Sistema no lineal
.........................................................
29
30
31
31
33
34
34
35
35
35
36
37
37
38
38
39
39
40
40
41
41
41
42
44
45
47
48
48
48
49
49
51
51
52
52
53
53
57
58
58
58
58
59
60
60
60
61
61
62
63
63
63
63
64
65
67
68
68
68
70
70
71
71
71
73
74
74
75
77
78
78
78
80
81
81
82
83
84
87
D CONSIDERACIONES FINALES
D.1 TRATAMIENTO DE JUNTAS Y SUPERFICIES
................................
D.1.1 Juntas continuas (invisibles)
......................................................
D.1.2 Junta destacada
................................................................
D.1.3 Junta exible (de control)
......................................................
D.1.4 Pasos a seguir ...........................................................................
D.2 EQUIPOS, HERRAMIENTAS Y ELEMENTOS DE SEGURIDAD
...........
D.2.1 reas de aplicacin ................................................................
D.2.2 Movilizacin, colocacin y sustentacin
................................
D.2.3 Medicin, trazado y nivelacin
...........................................
D.2.4 Corte y armado de bastidores metlicos
................................
D.2.5 Anclajes, armaduras y emplacado
...........................................
D.2.6 Tratamiento de juntas y supercies
...........................................
D.2.7 Equipos de proteccin, seguridad y asistencia .................................
95
96
96
97
98
101
102
103
104
105
106
107
108
A.
INFORMACIN GENERAL
A. INFORMACIN GENERAL
ETERNIT COLOMBIANA S.A
A.1 PRESENTACIN
INFORMACIN GENERAL
A.2 LA EMPRESA
ETERNIT, empresa Colombiana creada desde
1.942 y con ms de 65 aos de experiencia
en la fabricacin de productos de fibrocemento,
ha dedicado sus esfuerzos en busca de mejores
soluciones constructivas en el acelerado proceso
de urbanizacin que experimenta nuestro pas.
Mas de 300 millones de metros cuadrados
cubiertos con tejas eternit, alrededor de 1 milln
y medio de viviendas servidas con sus tanques
y cerca de 40.000 kilmetros de tubera de
acueducto y alcantarillado a lo largo y ancho de
su territorio nacional son algunos de sus aportes.
ETERNIT cuenta con 3 fbricas ubicadas en
las ciudades de Bogot, Barranquilla y Cali
que hacen posible nuestra presencia en todo el
territorio nacional a travs de una nutrida red
de Distribuidores. As mismo, ha incursionado
exitosamente
en
los
mercados
vecinos,
principalmente en Panam, Aruba, Curazao,
Costa Rica, Per, Venezuela, Ecuador, Antillas
Holandesas y Republica Dominicana.
INFORMACIN GENERAL
A.3 LA MULTINACIONAL
El grupo MEXALIT cuenta con ms de 70 aos de
historia y una capacidad de produccin superior
a 1.800.000 toneladas por ao en la fabricacin
de Productos de Fibrocemento, Polietileno, y
Concreto para la industria de la construccin.
El grupo MEXALIT est conformado por un extenso
conjunto de empresas lideres en su ramo que
proporcionan ms de 3.500 fuentes de empleo
permanente, entre las cuales se encuentran:
Mexalit Industrial (Productos FC y Contenedores
de Agua, Mxico)
INFORMACIN GENERAL
La informacin, referencias y marcas que se incluyen en este manual estn sujetas a cambios que
podrn ser obtenidos en nuestra pgina web www.eternit.com.co.
Fotos A.1, A.2 y A.3 Centro de eventos del Valle del Pacfico - Valle del Cauca - 2007
Notas y referencias
INFORMACIN GENERAL
TIPO
1)
2)
3)
4)
5)
6)
7)
8)
Grficos ilustrativos con textos de referencia.
Perfil U ,canal
Perfil C, canal, perlin
Tubular o cajn
Tubular reforzado
Perfil I
Perfil I reforzado
Compuesto. triple
Compuesto reforzado
GEOMETRAS
PGU
PGC
2 PGC rgido. enfrentados
2 PGC + 2PGU
2 PGC almas enfrentada
2 PGC + 2PGU
1 cajn + 1 PGC
1 cajn + 2 PGC
INFORMACIN GENERAL
10
A.7.1
VENTAJAS
DEL
SISTEMA
CONSTRUCTIVO EN SECO ETERNIT
INFORMACIN GENERAL
11
INFORMACIN GENERAL
CARACTERSTICAS
AISLANTE
CORTA FUEGO
HIDRFUGO
(RH)
CONDICIN
(RF)
LIVIANO
INERTE
PRCTICO Y
ECONMICO
La flexibilidad de este sistema para participar en las diferentes arquitecturas que se propongan facilita
que infraestructuras como instalaciones sanitarias, hidrulicas, elctricas, mecnicas, de comunicaciones
o cualquier otra se incluyan dentro de ductos, muros de servicio o espacios entre paramentos o en el
pleno de cielos rasos con la posibilidad de acceder en cualquier momento a ellas para la realizacin
de controles, mantenimientos, ampliaciones o modificaciones. Esta propiedad le otorga al sistema
Constructivo en seco ETERNIT un valor agregado de sostenibilidad.
12
B.
Los componentes son los elementos o materiales, individuales o agrupados que hacen parte de una
solucin constructiva en seco. Para el sistema constructivo en seco, ETERNIT fabrica en la actualidad,
las placas de fibrocemento ETERBOARD, las masillas ETERCOAT (HR y MR) y ETERGLASS (HF y MF),
denominados componentes propios y que se describen con la sigla SFE. Otros componentes no
fabricados por ETERNIT y que hacen parte integral e indispensable en este sistema son denominados
no propios y su sigla es NFE.
El sistema constructivo en seco ETERNIT est
conformado por cuatro componentes:
1. Componente NFE-1: Perfiles metlicos.
2. Componente SFE-1: Placas planas de
fibrocemento ETERBOARD.
3. Componente NFE-2: Anclajes y fijaciones.
4. Componente SFE-2: Sellos, cintas y masillas
ETERCOAT (HR, MR) y ETERGLASS (HF, MF).
B.1 COMPONENTE NFE - 1 PERFILES
METLICOS
Formas geomtricas dadas en toda su longitud a
una seccin de lmina metlica. Con los avances
tecnolgicos en la produccin de aceros y las
maquinarias especializadas, se fabrican perfiles
en diferentes formas, longitudes y calibres
Los procesos de fabricacin de perfiles son:
Doblado: Se toman tiras de lminas metlicas
y se les da formas, generando dobleces con el uso
de una mquina dispuesta para tal fin denominada
dobladora.
IMPORTANTE
Se denominan bastidores a los entramados o
esqueletos construidos con perfiles metlicos,
que conforman una estructura capaz de recibir
emplacado (Grfico B.2).
De acuerdo con las solicitudes estructurales
impuestas por el diseo, una construccin en seco
se puede considerar como:
Autoportante: (balloon framing), que es cuando
todos sus componentes son los encargados de
trasmitir a la cimentacin las cargas propias de
la edificacin tales como el peso propio, muebles
y enseres, personas, carga ssmica de vientos
etc. En este caso se deben usar en los bastidores
perfiles estructurales.
Confinada: (platform framing), es aquella
construccin en seco que se realiza dentro de los
lmites de una estructura existente y funciona como
elemento de divisin o conformacin de espacios.
Si algunos de sus elementos reciben cargas se
consideran como colaborantes estructurales.
No estructural: Se dice de todos los elementos
de una obra que no estn sujetos a ningn tipo de
esfuerzo ms que su propio peso, son considerados
como elementos arquitectnicos.
14
Tabla B.1
15
B.1.2.2 CARPINTERAS
Formas y conjuntos
Prolongacin de perfiles
Para obtener dimensiones mayores a las estndar,
se ensamblan dos o ms secciones de perfil
mediante el uso de canales o parales unidos con
los tornillos necesarios para garantizar estabilidad
y resistencia.
TIPOS DE UNIN: Solapa interior o exterior
Adosados
En uniones telescpicas.
GEOMETRAS
TIPO
1) Perfil U ,canal
PGU
PGC
3) Tubular o cajn
4) Tubular reforzado
2 PGC + 2PGU
5) Perfil I
6) Perfil I reforzado
2 PGC + 2PGU
7) Compuesto. triple
1 cajn + 1 PGC
8) Compuesto reforzado
1 cajn + 2 PGC
No estructurales
Calibre
26
mm
0.46
24
0.61
22
0.75
20
0.90
0,0354
18
1.20
0,0472
16
1.50
0,0591
14
2.00
0,0748
12
2.50
0,0984
Estructurales
Pulgada
CALIBRE
26 a 18
Parales
26 a 18
Perfiles (est.)
24 a 12
Estructuras primarias
Viguetas
26 a 24
Omegas
26 a 24
ngulos
26 a 24
Cintas
26 a 18
Contravientos, sujetadores
TIPO
16
FORMATO
mm
PESO
kg/cm2
605 x 1214
4.12
USOS RECOMENDADOS
1220 x 1220
8.35
1220 x 2440
24.60
1220 x 2440
32.80
10
1220 x 2440
42.00
14
1220 x 2440
57.40
17
1220 x 2440
73.00
20
1220 x 2440
85.88
Versatilidad de uso
Fcil de trabajar, permite: Serruchado, rayado,
ruteado, perforado, atornillado y clavado, lijado
y cepillado. Recibe una variedad de acabados
arquitectnicos y recubrimientos.
Versatilidad de oferta
Diferentes espesores adecuados a diversos usos.
Trabajable
Se corta y perfora con herramientas manuales
o elctricas, facilitando su transformacin y
minimizando los desperdicios.
Tabla B.5
17
CARACTERSTICAS FSICO-MECNICAS
DESCRIPCIN
UNIDAD
CLASIFICACIN
Tipo
Categora
TOLERANCIAS
Espesor
Largo
Ancho
CANTIDAD
ENSAYO
NTC-4373
Cuadratura
RESISTENCIA A FLEXIN
Saturado longitudinal
Saturado transversal
Seco longitudinal
Seco transversal
MDULO DE ELASTICIDAD
Saturado longitudinal
Saturado transversal
MOVIMIENTO HDRICO
Longitudinal (paralela)
Transversal (perpendicular)
RESISTENCIA AL IMPACTO
Seco al horno (Charpy))
Saturado
RESISTENCIA AL FUEGO
Propagacin de llamas
Produccin de humos
COEFICIENTE EXPANSIN TRMICA LINEAL
Paralelo
Perpendicular
OTROS VALORES
Densidad
Contenido de humedad
Absorcin de agua (sin hidrofugar)
Resistencia a la traccin al clavo seco
Conductividad trmica
mm
mm
mm
(+ -) 0,3
(+ -) 2
(+ -) 2
mm
(+ -) 4
MPa
MPa
MPa
MPa
10
7
15
9
MPa
MPa
4256
4216
ASTM 1185
mm/m
mm/m
1,2
1,1
ASTM D-1037
Kj/m2
Kj/m2
1,56
2,86
ASTM D-256
0
0
ASTM C-85
6,5 (*10-6)
ASTM D-1037
cm/C
cm/C
g/cm3
%
%
Kg
W/mC
MPa= Mega Pascal
1,25
2,72
35
64,7
0,263
Kj=Kilo Julio
Internas
NTC-4373
NTC-4373
ASTM 1185
NTC-4373
ASTM C-518
ASTM C-518
W= Watio
Borde estndar a
escuadra para Borde rebajado en obra para emplacados Borde en bisel en obra para emplacados
emplacados con juntas dilatadas, sin con juntas tratadas (invisibles o con juntas flexibles, a la vista y esquinas
tratamiento y juntas de control.
continuas).
toscana.
Cuando el ETERBOARD est expuesto a la intemperie o humedad, se debe tratar previamente con
imprimante COLORCEL por la contra cara o dos caras, para equilibrar tensiones.
18
ESPESOR
mm
4
4
6
8
10
14
17
20
FORMATO CANTIDAD/
ARRUME
mm
605 x 1214
1220 x 1220
1220 x 2440
1220 x 2440
1220 x 2440
1220 x 2440
1220 x 2440
1220 x 2440
320
160
120
90
70
50
40
35
PESO TOTAL
kg
1.318
1.336
2.952
2.952
2.940
2.870
2.920
3.005
IMPORTANTE
B.2.3 TRANSPORTE
Las placas se colocan sobre las estibadas o
plataformas de transporte mediante montacargas
o por operarios con guantes o manos limpias. Si
no estn estibadas y con protector plstico contra
lluvias, se deben cargar en carros con carpa o
cubrir el material con lminas de polietileno.
Evite que las placas sufran golpes que fracturen
sus bordes. Al descargar el material y si no se
dispone de un montacargas, se deben bajar una
a una, con dos personas como mnimo, cargarlas
perpendicularmente, y no acostadas como vienen
en la estiba, ya que se pueden fracturar.
B.2.4 ALMACENAMIENTO
Las placas planas ETERBOARD se deben
almacenar bajo techo, en lugares ventilados,
no expuestas a los rayos del sol. Arme arrumes
de 80 cm mximo y no coloque superpuestos
ms de cuatro. Se deben dejar distancias entre
arrumes lo suficientemente amplias para permitir
su desplazamiento y evitar que equipos de
transporte las golpeen en sus bordes.
19
ESPESOR
mm
4
4
6
8
10
14
17
20
FORMATO CANTIDAD/
ARRUME
mm
605 x 1214
1220 x 1220
1220 x 2440
1221 x 2440
1222 x 2440
1223 x 2440
1224 x 2440
1225 x 2440
320
160
120
90
70
50
40
35
PESO TOTAL
kg
1.318
1.336
2.952
2.952
2.940
2.870
2.920
3.005
IMPORTANTE
B.2.3 TRANSPORTE
Las placas se colocan sobre las estibadas o
plataformas de transporte mediante montacargas
o por operarios con guantes o manos limpias. Si
no estn estibadas y con protector plstico contra
lluvias, se deben cargar en carros con carpa o
cubrir el material con lminas de polietileno.
Evite que las placas sufran golpes que fracturen
sus bordes. Al descargar el material y si no se
dispone de un montacargas, se deben bajar una
a una, con dos personas como mnimo, cargarlas
perpendicularmente, y no acostadas como vienen
en la estiba, ya que se pueden fracturar.
B.2.4 ALMACENAMIENTO
Las placas planas ETERBOARD se deben
almacenar bajo techo, en lugares ventilados,
no expuestas a los rayos del sol. Arme arrumes
de 80 cm mximo y no coloque superpuestos
ms de cuatro. Se deben dejar distancias entre
arrumes lo suficientemente amplias para permitir
su desplazamiento y evitar que equipos de
transporte las golpeen en sus bordes.
19
Son los elementos encargados de unir, fijar o sostener las estructuras o bastidores metlicos entre s o
entre ellas y otros sustratos, fijar los emplacados y otros elementos que puedan tener relacin con la
solucin constructiva a tratar. Por ejemplo: Muebles, instalaciones, tuberas, etc.
Principalmente se conocen los siguientes tipos de anclajes y fijaciones:
Anclajes mecnicos (metlicos, plsticos).
Anclajes qumicos (mono componente, bicomponente y morteros con cementos polimricos).
Tornillos de fijacin.
Clavos.
B.3.1 ANCLAJES MECNICOS
IMAGEN
TIPO PESADO, SEMIPESADO Y LIGERO
TIPO DE ANCLAJE
Corte kg
150 a 600
Anclaje roscado en acero al carbn con zincado 200 a 1300 220 a 1500
3/8, 5/8 y tipo LDT (Large Diameter
Tapcom)
Clavos de fijacin a plvora Tipo sdm a 1 Tr. 40 Ct.
100 Tr. 60
Tipo Nk de 1 a 1
30 a 120
Ct. 177
Resistencia extraccin (kg)
Concreto
Bloque
10 a 30
5 a 12
80 a 500
50 a 150
Tabla B.9
Pernos de expansin
Los pernos de expansin se caracterizan porque la fijacin al sustrato se obtiene por la presin que
partes de sus elementos ejercen en el orificio taladrado, estn diseados para soportar grandes, medias
o pequeas cargas y cortantes. Son principalmente los ms usados en las soluciones constructivas en
seco ya que se consiguen en una gran variedad de longitudes, dimetros y resistencias. Los pernos de
expansin son usados en sustratos de concreto e inclusive metlicos, no son recomendados para anclar
sobre madera.
20
IMPORTANTE
Las resinas usadas para anclajes pueden ser
epxicas, poliestricas, vinlicas y particularmente
de carcter tixotrpico (que no escurren al
adecuarse al perno).
Los productos qumicos para anclajes se
presentan en cpsulas en sistemas de uno o dos
componentes y en tubos, barras o potes de mayor
cantidad
NOMBRE
Anclaje plstico universal con tornillo
ITEM
10
Grafico B10.
21
IMPORTANTE
Los tornillos que unen los perfiles metlicos de un bastidor deben sobresalir en su paso mnimo en tres
hilos de la rosca para que la fijacin sea aceptable.
Los tornillos autoperforantes con aletas tienen la funcin de horadar el ETERBOARD en un dimetro
mayor a la del vstago del tornillo para evitar esfuerzos de cizallamiento, una vez que penetra la punta
perforante en el perfil, las aletas se desprenden y actan los hilos de roscado.
IMAGEN
TORNILLO
TPF 114 # 7 y 8 1
TPF 134 # 7 y 8 1
Acero micro aleado y
zincado
Tornillos ETERBOARD
, 1 y 1
CARACTERSTICAS
T1 # 7 7/16
Tornillos auto perforantes con cabeza extra plana
# 8 7/16 y 3/4 para armar bastidores que se recubrirn con
Acero microaleado y
ETERBOARD.
zincado (pan head)
T1 # 7 7/8
Tornillo auto perforante para armar estructuras de
Acero micro aleado y
bastidor que no tengan emplacado.
zincado (lenteja)
T-HEX # 8 a 12
Tornillo auto perforante para unir perfiles de
De a 1
mayor calibre sin emplacado, en estructuras de
Acero micro aleado y
soporte de bastidores.
zincado
NOTA: Todos los tornillos son en acero microaleado y zincado.
El tornillo T1 se consigue tambin en negro (fosfatado) y punta fina.
Tabla B.11
Tabla B.12
22
DESCRIPCIN/VALORES
Material
Presentacin
Balde (2 galones)
Cuete (5 galones)
Peso neto
10 y 25 kilos respectivamente
Viscosidad
55000 - 5000 cP
Tiempo de endurecimiento
Variable
23mbar (agua)
Gravedad especfica
1.32
Rango de ph a 25C
89
Tamao de partculas
Variable
Rendimiento
Agrietamiento
Ninguno
Resistencia a productos
qumicos
Contraccin
6.99%
Punto de ebullicin
100C
Estabilidad y reactividad
qumica
Estable
No polimerizaciones peligrosas
Descomposicin peligrosa
Punto de ignicin
No aplica
Punto de congelacin
0C
Color
Beige
Vigencia
1 ao (correcto almacenamiento)
Adherencia en ETERBOARD
Excelente
Olor
Levemente aromtico
Contenido cov
No determinado
Porcentaje voltil
Riesgo incendio/explosin
Ninguno
Material peligroso
Ninguno
B.4.1.1 RECOMENDACIONES
Almacenamiento
Rote el producto cada 90 das.
Almacene el producto en lugar cubierto, fresco y
seco, evite condiciones extremas de calor o fro.
Antes de aplicar la masilla, consulte las
instrucciones.
Apile como mximo tres recipientes.
Manipulacin segura
Tabla B.13
Generales
Antes de aplicar ETERCOAT la superficie a tratar
debe estar libre de polvo e impurezas.
No diluya el producto con agua ya que esto
afecta la calidad y las propiedades de aplicacin
de la masilla.
No mezcle el producto con ningn otro tipo de
masilla en polvo o en dispersin.
B.4.1.2 INFORMACIN ADICIONAL
23
DESCRIPCIN/VALORES
Material
Presentacin
Balde (2 galones)
Cuete (5 galones)
Peso neto
11 y 27 kilos respectivamente
Viscosidad
125000 - 10000 cP
Tiempo de endurecimiento
Variable
23mbar (agua)
Gravedad especfica
1.70
Rango de ph a 25C
89
Tamao de partculas
Variable
Rendimiento
7 m / galn
Agrietamiento
Ninguno
Resistencia a productos
qumicos
Encogimiento
Menor al 2%
Punto de ebullicin
100C
Estabilidad y reactividad
qumica
Descomposicin peligrosa
Punto de ignicin
No aplica
Punto de congelacin
0C
Color
Blanco
Vigencia
1 ao (correcto almacenamiento)
Adherencia en ETERBOARD
Excelente
Olor
Levemente amoniacal
Contenido cov
No determinado
Porcentaje voltil
Riesgo incendio/explosin
Ninguno
Material peligroso
Ninguno
B.4.2.1 RECOMENDACIONES
Almacenamiento
Rote el producto cada 90 das.
Almacene el producto en un lugar cubierto,
fresco y seco, evite almacenarlo en condiciones
extremas de calor o fro.
Manipulacin segura
Minimice la generacin y acumulacin de polvo;
evite inhalar el polvo y que ste entre en contacto
con los ojos.
Utilice una adecuada proteccin respiratoria en
el momento de lijar la superficie.
Generales
Tabla B.14
24
moderadamente
IMPORTANTE
(ETERCOAT Y ETERGLASS)
No explosiva.
Baja toxicidad Puede causar irritacin.
En caso de escape y/o derrame
Remover por mtodos de limpieza secos la mayor
cantidad de material antes que el material seque,
posteriormente lavar con agua.
Depositar en contenedores secos y limpios con
cierre hermtico.
B.4.4 CINTA
(Adhesiva)
DE
FIBRA
DE
VIDRIO
COMPONENTES DEL SISTEMA
No inflamable.
25
26
C.
SOLUCIONES CONSTRUCTIvAS
C. SOLUCIONES CONSTRUCTIVAS
SOLUCIONES CONSTRUCTIVAS
Las nuevas tendencias constructivas y las exigencias de los consumidores exigen que las edificaciones
contemporneas respondan con agilidad, flexibilidad y versatilidad que permita posibilidades de
renovacin o ampliacin de las mismas; hecho ste que se constituye en el plus ms importante de las
construcciones en seco (livianas) de reconocida sostenibilidad.
C.1 SOLUCIN PARA MUROS SECOS
PARA
FACHADAS
28
C.1
MUROS SECOS
SECOS
SOLUCIONES CONSTRUCTIVAS
MUROS SECOS
C.1
30
C.1.2 COMPONENTES
Componentes principales (Grfico 1) de los muros
o tabique en seco: Bastidores de metal o madera,
placas ETERBOARD, fijaciones y anclajes y cintas,
sellos y masillas.
C.1.2.1 EL BASTIdOR
El bastidor es el esqueleto estructural y garantiza
la estabilidad y solidez del tabique. Permite
la fijacin del ETERBOARD con tornillos TPF en
sus paramentos. Se construye con parales (perfil
C) y canales (perfil U), unidos con tornillos auto
perforantes. El uso de cintas metlicas para los
contravientos o cruz de San Andrs y ngulos de
rigidizacin complementan su armado.
MUROS SECOS
C.1
31
IMPORTANTE
MUROS SECOS
C.1
Grfico C.1.7
Bastidores arqueados
El mtodo de sangrado permite obtener curvados
con radios >= 60 cm, consiste en cortes en las alas
y alma del canal para que al abrir o cerrar por
stos, se formen secciones de arco. La colocacin
de una cinta metlica a lo largo del sangrado
colabora con su estabilidad.
Grfico C.1.6
32
FORMATO (cm)
122 x 244 cm
122 x 244 cm
122 x 244 cm
PESO (kg)
24.60
32.80
42.00
APLICACIN
Recubrimientos y muros curvos
Muros o tabiques interiores arqueados o planos
Muros de gran altura y/o propensos a impacto
C.1
Emplacado
Es la accin de forrar con placas un bastidor
en una o ambas caras (flancos o paramentos) y
de una forma alternada. Si las placas requieren
de cortes o perforaciones, se deben realizar
siguiendo lo sealado en este manual (Ver seccin
Herramientas).
La superficie de apoyo de las placas debe estar
nivelada o curvada segn el tipo de muro. Los
tornillos de armada del bastidor deben ser de
cabeza extra plana para un mejor asentamiento
de las lminas. El emplacado debe realizarse en
el orden expresado en el Grfico 10.
Grfico C.1.11
IMPORTANTE
33
Modulaciones
MUROS SECOS
Son las distancias entre ejes de parales. Las modulaciones estn en relacin con las solicitudes
estructurales y la forma de emplacado. Las corrientes son: Cada 61 cm, 48,8, 40,7 y 30,5.
C.1
Grfico C.1.13
34
Remate de esquinas
Aunque las placas ETERBOARD presentan una
dureza y resistencia a los impactos, para lograr
esquinas perfectas se deben reforzar o tratar.
Grfico C.1.14.
Juntas de dilatacin
El emplacado se realiza, dejando separaciones
entre placas (3 a 10 mm) (Grfico C.1.15) y contra
otros elementos de la construccin, como vigas de
concreto, acero o madera, muros de mampostera
etc, en prevencin a los movimientos propios de los
elementos y otros esfuerzos (movimientos ssmicos,
vibraciones, asentamientos, expansiones).
Ubicacin
Dilatacin (mm)
Entre placas
3a8
5a8
8 a 10
MUROS SECOS
C.1
Grfico C.1.15.
35
MUROS SECOS
C.1
Grfico C.1.16
IMPORTANTE
Los muros de divisin no estn capacitados para recibir esfuerzos axiales, slo se considera su peso
y carga lateral de +/- 25 kg/m para el clculo de las deflexiones permitidas. Los muros interiores de
carga se disean para soportar su peso, otros adicionales y cargas axiales <= 195 kg/m.
36
MUROS SECOS
C.1
Grfico C.1.21
37
IMPORTANTE
MUROS SECOS
C.1
38
Grfico C.1.23
Grfico C.1.22
C.1.4 AISLAMIENTOS
C.1.4.1 TRMICOS
MUROS SECOS
C.1
AISLANTES TRMICOS
Material
Conductividad trmica
Lana de vidrio
0,056 a 0,030 W/mK
En la especificacin y clculo de los aislamientos se
deben tener en cuenta varios factores: Temperatura
Espuma de poliestireno
0,041 a 0,039 W/mK
ambiente, humedad relativa, punto de roco,
Espuma de poliuretano
0,021 a 0,019 W/mK
altura sobre el nivel del mar, intensidad sonora,
Espuma celulsica
0,023 a 0,021 W/mK
focos de vibracin, intensidad de lluvias, vientos
ETERBOARD
0,265 W/mK
predominantes etc. Las recomendaciones de los
Tabla C.1.3.
fabricantes, calculistas y diseadores determinan
las caractersticas de cada proyecto. Los
aislamientos son tres principalmente: Trmicos, datos comparativos
acsticos y de humedad y vapor. Estos
W/mk = vatio/metro kelvin.
aislamientos intentan conseguir un buen nivel
Congelacin del agua = 0C.
de comodidad, entendida como la ausencia de
C=K-273,15 K= C + 273,15.
molestias sensoriales.
C=(F-32)/1,8.
39
C.1.4.2 ACSTICOS
MUROS SECOS
masa
Medianeros
Divisorios
De reas comunes
Multifamiliares
Divisorios de reas de reunin
Oficinas
Linderos con el exterior
C.1
Hospitalarios
Hotelera
AISLANTE
3 1/2 (LV)
CARA 2
mm
AISLAMIENTO (db)
No
27 - 18
10
No
10
32 - 20
36 - 22
10
10
42 - 24
Construccin hmeda
27.10 kg / m2
160 kg / m2
40
De habitaciones hospitalarias
Para aislar reas ruidosas
RW
(dB)
37
48
44
48
56
44
40
56
48
56
Tabla C.1.6
MUROS SECOS
C.1
Grfico C.1.25
41
MUROS SECOS
Grfico C.1.26
UNIONES PARA DIFERENTES APLICACIONES CONSTRUCTIVAS DE MUROS EN SISTEMA EN SECO CON PLACAS ETERBOARD
C.1
IDENTIFICADOR
L a placa pasante
L a bastidor agrupado
Nombres de componentes
DETALLE A Y C, opcin 1
DETALLE A Y C, opcin 2
DETALLE A Y C, opcin 3
DETALLE A Y C, opcin 4
DETALLE B Y D, opcin 1
DETALLE B Y D, opcin 2
DETALLE B Y D, opcin 3
DETALLE B Y D, opcin 2
Tabla C.1.7
42
F. colocacin de placas
X a placas pasantes
Muro doble
Fijaciones y sentido de
parales y placas
MUROS SECOS
E. terminal ciego
X a bastidor agrupado
C.1
Tabla C.1.8
43
Notas de clculo
MUROS SECOS
Pasos de clculo
C.1
1.
Establecer en el plano arquitectnico el
muro interior que se desea calcular, conocer su
alto, ancho y espesor.
2.
La especificacin del muro, acabado y
trabajo estructural determina su carga lateral (20
a 60 kg/m). Para muros en ETERBOARD con
pintura y enchapados.
3.
Establecer segn clculos y tablas la
deflexin correspondiente al muro (L/240 a
L/360)
4.
Con estos valores las tablas de perfiles
metlicos suministran las posibilidades a usar, que
varan en seccin y calibre, segn la modulacin
y el espesor del ETERBOARD.
5.
Determinado el paral metlico del bastidor
la canal del mismo debe tener igual calibre o
mximo uno menor (paral C/20 canal C/20 o
mnimo C/ 22).
6.
La altura del muro determina si se deben
usar sujetadores horizontales o riostras, las que
se instalan cada 244 cm como mnimo.
Los fabricantes de perfiles metlicos para
Drywall, suministran las tablas referidas.
NORMAS DE CONSULTA
NSR 98: Muros portantes y elementos
arquitectnicos.
ASTM C 645-04 a AST C955-03: Fabricacin
de perfiles.
NTC 4373: Fibrocementos.
44
PARAL REF
ALMA
H (mm)
PF32CAL24
PF92CAL22
92
92
CANAL REF
ALMA
H (mm)
C93CAL24
C93CAL22
93
93
ALAS
B (mm)
D (mm)
45
42
45
42
PESTAA
C (mm)
6.35
6.35
ALAS
B (mm)
D (mm)
25
24
25
22
ESPESOR
Calibre
T (mm)
24
0.60
22
0.75
LONGITUD
L (m)
2.44
3.05
2.44
3.05
ESPESOR
Calibre
T (mm)
24
0.60
22
0.75
LONGITUD
L (m)
2.44
3.05
2.44
3.05
MUROS SECOS
C.1
Tipo de muro
Interior
Deflexin
Altura del muro (m)
Referencia Wg (kg/m)
L/240
2.44 3.05 4.00
L/300
2.44 3.05 4.00
Modulaciones
L/360
2.44 3.05 4.00
59P35-26
0.47
0.610
0.610
89P35-26
0.58
0.610
0.488
92P45-24
0.88
0.610
0.610
0.488
0.488
0.488
0.488
0.610
0.610
0.407
92P45-22
1.10
0.610
0.610
0.488
0.488
0.488
0.488
0.610
0.488
0.488
92P45-20
1.24
0.610
0.610
0.488
0.610
0.407
0.407
0.488
0.407
45
MUROS SECOS
C.1
Atlntico
46
C.2
FACHADAS Y CERRAMIENTOS
SOLUCIONES CONSTRUCTIVAS
FACHADAS Y CERRAMIENTOS
C.2
Grfico C.2.1
Grfico C.2.2
48
DE
FORMATO
cm
122 X 244
PESO
Kg
42
APLICACIN
14
122 X 244
57.40
Tipo 2 y 3
17
122 X 244
73
Tipo 3 y 4
20
122 X 244
85.88
Tipo 4
Tipo 1 y 2
Fijacin horizontal
FACHADAS Y CERRAMIENTOS
C.2
Fijacin vertical
Tabla C.2.1
Tipo1:
Tipo2:
Tipo3:
Tipo4:
ETERBOARD
ETERBOARD
ETERBOARD
ETERBOARD
masillado y pintado.
enchapado cermico.
dilatado.
en fachada ventilada.
Grfico C.2.3
49
MUROS SECOS
C.1
Carcter
del medio
Proteccin
del anclaje
Marino
Muy agresivo
Alta y media
Industrial
Muy agresivo
Alta y media
Urbano
Medio agresivo
Media y baja
Rural
Poca agresividad
Baja o nula
Neblinas Media/poca agresividad
Baja
Clima clido Media/poca agresividad
Baja
Tabla C.2.2. Determinantes ambientales para anclajes
de fachadas.
50
FACHADAS Y CERRAMIENTOS
Grfico C.2.5
C.2
Grfico C.2.6
Modulaciones de fijacin
La modulacin (separacin entre ejes de parales)
depende del tipo de fachada, su altura y otros
requerimientos estructurales; las ms usuales en
emplacados paralelos (verticales) son: 61, 40.7
y 30.5 cm y en emplacados perpendiculares
(transversales) son: 61, 48.8, 40.7 y 30.5.
IMPORTANTE
Las
fachadas
arqueadas
requieren
de
modulaciones menores (40.7 y 30.5) para lograr
un mejor efecto de curvado, as mismo se requiere
de un mayor nmero de tornillos (C/20, 25 cm)
que garanticen la sustentacin de la placa.
Grfico C.2.7
Grfico C.2.8
Grfico C.2.9
SISTEMA CONSTRUCTIVO EN SECO
51
FACHADAS Y CERRAMIENTOS
ESPESOR
Placa 8 mm
Placa 10 mm
RADIO MNIMO
80 cm
100 cm
IMPORTANTE
EL ETERBOARD se debe humedecer por inmersin
en agua por un periodo de 8 horas antes de
proceder al curvado. Al fijar las placas se debe
tener cuidado de no aplicar demasiada fuerza al
tornillo ya que el material se encuentra blando.
C.2.3.3 RECUBRIMIENTOS
C.2
Grfico C.2.10
De paramento arqueado
Una de las caractersticas del ETERBOARD, es su
capacidad de arquearse y adoptar las curvaturas
del bastidor. stas formas se logran colocando los
parales encajados en canales de sangrado abierto
o cerrado, reforzado con una cinta metlica fijada
a lo largo del ala sangrada conformando un perfil
curvo de fijacin y gua.
Grfico C.2.12
Grfico C.2.11
52
tipos de recubrimiento
MUROS SECOS
Grfico 2.13
C.1
Grfico C.2.14
53
MUROS SECOS
C.1
ID
LONGITUD
LATITUD
ESTACIN
DEPARTAMENTO
VELOCIDAD
PROMEDIO
DEL VIENTO
7516W
1047N
GALERAZAMBA
BOLVAR
5.9
7333W
0526N
GACHANECA
BOYAC
5.5
8143W
1235N
AEROPUERTO SESQUICENTENARIO
5.1
7444W
0320N
LA LEGIOSA
HUILA
4.1
8121W
1322N
AEROPUERTO EL EMBRUJO
ISLA DE PROVIDENCIA
4.0
7256W
1132N
GUAJIRA
4.0
7330W
0532N
VILLA CARMEN
BOYAC
3.9
7718W
0111N
OBONUCO
NARIO
3.5
7231W
0756N
NTE DE SANTANDER
3.3
10
7607W
0620N
URRAO
ANTIOQUIA
3.0
11
7436W
10 536N
ATLNTICO
2.9
12
7414W
11708N
MAGDALENA
2.9
13
7311W
0708N
AEROPUERTO PALONEGRO
SANTANDER
2.8
14
7508W
0335N
ANCHIQUE
TOLIMA
2.7
15
7314W
0805N
NTE DE SANTANDER
2.5
16
7409W
0443N
CUNDINAMARCA
2.2
Nota: Estos datos son de informacin general y fueron tomados de varios documentos del IDEAM,
UPM, Ministerio del Ambiente, Vivienda y Desarrollo territorial y del Ministerio de minas y energa de
la Repblica de Colombia.
54
Interior
Fachada
Tipo de
muro
Interior
Fachada
Tipo de
muro
Interior
Fachada
Ciudad
N caso
Altura muro (m)
Referencia Wg [kg/m]
3.05
4.00
2.44
3.05
4.00
2.44
3.05
4.00
---
2.44
3.05
4.00
2.44
3.05
4.00
2.44
3.05
4.00
FACHADAS Y CERRAMIENTOS
Tipo de
muro
---
0.488
---
---
C.2
59P35-26
0.47
0.610
---
---
0.610
---
---
---
---
89P35-26
0.58
0.610
0.610
0.305
0.610
0.610
0.305
---
---
---
92P45-24
0.88
0.610
0.610
0.488
0.610
0.610
0.488
0.610
0.610
0.488
92P45-22
1.10
0.610
0.610
0.488
0.610
0.610
0.488
0.610
0.610
0.488
92P45-20
1.24
0.610
0.610
0.488
0.610
0.610
0.488
0.610
0.610
0.488
120P45-22
1.26
0.610
0.610
0.610
0.610
0.610
0.610
0.610
0.610
0.610
150P45-20
1.63
0.610
0.610
0.610
0.610
0.610
0.610
0.610
0.610
0.610
Ciudad
N caso
Altura muro (m)
Referencia Wg [kg/m]
59P35-26
0.47
0.488
---
---
0.488
---
89P35-26
0.58
0.610
0.610
0.305
0.610
0.610
---
0.610
0.610
---
92P45-24
0.88
0.610
0.610
0.407
0.610
0.610
0.305
0.610
0.610
0.407
92P45-22
1.10
0.488
0.610
0.488
0.610
0.610
0.488
0.610
0.610
0.610
92P45-20
1.24
0.610
0.610
0.610
0.610
0.610
0.610
0.610
0.610
0.610
120P45-22
1.26
0.610
0.610
0.610
0.610
0.610
0.610
0.610
0.610
0.610
150P45-20
1.63
0.610
0.610
0.610
0.610
0.610
0.610
0.610
0.610
0.610
Ciudad
N caso
Altura muro (m)
Referencia Wg [kg/m]
3.05
4.00
2.44
3.05
4.00
2.44
3.05
4.00
---
59P35-26
0.47
0.488
---
---
0.610
0.305
---
---
---
89P35-26
0.58
0.610
0.610
0.305
0.610
0.610
---
---
---
---
92P45-24
0.88
0.610
0.610
0.488
0.610
0.610
0.488
0.610
0.610
0.407
92P45-22
1.10
0.610
0.488
---
0.610
0.488
---
0.610
0.488
---
92P45-20
1.24
0.610
0.610
---
0.610
0.610
---
0.610
0.610
---
120P45-22
1.26
0.610
0.610
0.407
0.610
0.610
0.407
0.610
0.610
0.305
150P45-20
1.63
0.610
0.610
0.610
0.610
0.610
0.610
0.610
0.610
0.610
55
FACHADAS Y CERRAMIENTOS
C.2
Notas:
- No obstante estas ayudas de clculo, recomendamos que los diseo sean revisados por
un ingeniero competente quien debe certificar la
fidelidad de los procedimientos y la aplicabilidad
de su utilizacin.
- La informacin aqu incluida NO COMPROMETE
a Perfilamos S.A., ni a ETERNIT, ya que es de
libre y voluntaria aplicacin.
- Las cargas consideradas corresponden a los
valores definidos por la Norma Colombiana de
Sismoresistencia 1998, de la siguiente forma:
Peso teja 7 kg/m
Peso correas 5 kg/m
Cielo Raso 10 kg/m
Otras Carga 5 kg/m
- El peso de las placas fue considerado de la
siguiente forma:
Placas de Fibrocemento Eterboard 10mm 42.00
kg/un
Placas de Fibrocemento Eterboard 14mm 57.40
kg/un
- Los perfiles deben ir en seccin sencilla, con
riostras separadas cada L/2 (L:Luz) mximo 2m.
Los perfiles sombreados requieren dos lneas de
tirantes.
- La pendiente considerada es de 1 (1.6%).
- La materia prima utilizada en Perfilamos S.A es
acero ASTM A-36 para los perfiles con espesores iguales o superiores a 1.5mm (Fy=25.3kg/
mm) y ASTM A568 G33 para los de 1.2mm
(Fy=23.2kg/mm).
Notas de clculo
NORMAS DE CONSULTA
NSR 98: Muros portantes y elementos
arquitectnicos.
ASTM C 645-04 a AST C955-03: Fabricacin
de perfiles.
NTC 4373: Fibrocementos.
56
C.3
ENTREPISOS
SOLUCIONES CONSTRUCTIVAS
ENTREPISOS
C.3
Grfico C.3.1
Grfico C.3.2
58
ESPESOR
mm
FORMATO
mm
PESO
Kg
14
1220 X 2440
57.40
17
1220 X 2440
73.00
20
1220 X 2440
85.88
ENTREPISOS
C.3
Grfico C.3.5
59
ENTREPISOS
C.3
Grfico C.3.6
60
ENTREPISOS
C.3
Grfico C.3.8
61
C.3.4 MODULACIONES
Las modulaciones o distancias entre ejes de viguetas estn dadas por los requerimientos estructurales de
cada entrepiso y generalmente son de 61, 48.8, 40.7 y 30.5 cm.
Sobre las viguetas se colocan las placas ETERBOARD en sentido perpendicular a ellas y desplazadas
(alternadas) entre s a 2/5, 1/4, 1/3 y 1/2 placa, segn lo modulado.
ENTREPISO M61
APLICACIN LIVIANA
Materiales / m
ENTREPISOS
ETERBOARD
Viguetas
Riostras
Rigidizadores
Tornillo T1 B
Tornillo T1 E
Tornillo TPF 1 5/8
C.3
m
ml
ml
Un
Un
Un
Un
1
1.64
0.74
5.5
5.5
21.5
15.5
ENTREPISO M48.8
APLICACIN SEMIPESADA
Materiales / m
ETERBOARD
Viguetas
Riostras
Rigidizadores
Tornillo T1 B
Tornillo T1 E
Tornillo TPF 1 5/8
m
ml
ml
Un
Un
Un
Un
1
2.05
0.72
6.71
6.71
27.9
13.5
ENTREPISO M40.7
APLICACIN PESADA
Materiales / m
ETERBOARD
Viguetas
Riostras
Rigidizadores
Tornillo T1 B
Tornillo T1 E
Tornillo TPF 1 5/8
Grfico C.3.11
m
ml
ml
Un
Un
Un
Un
1
2.46
0.7
8.06
8.06
32.3
15.8
Tabla C.3.2
Vanos
Los vanos o espacios libres en un entrepiso (Grfico 3.12) son tiles para el paso de escaleras, ductos
o vacos arquitectnicos y se ejecutan colocando viguetas dobles a ambos lados del vano y paralelas
a las viguetas seccionadas. Las viguetas descansan en una canal de recibo o riostra de carga, que se
ubica entre las viguetas dobles o reforzadas. La prctica seala que el nmero de viguetas cortadas para
ejecutar un vano, deben ser reemplazadas por el reforzamiento a los lados descrito anteriormente.
62
C.3.5.2 CERMICOS
Los pisos de pega hmeda requieren juntas
tratadas para evitar escurrimientos. La cara rstica
debe ser usada para la pega, e igualmente el
ETERBOARD tendr tratamiento hidrofugante
por sus dos caras. Los morteros acrlicos son los
apropiados para estas pegas.
Grfico C.3.12. Vano con doble vigueta.
ENTREPISOS
C.3.5 ACABADOS
C.3
Grfico C.3.14
Grfico C.3.13
SISTEMA CONSTRUCTIVO EN SECO
63
ENTREPISOS
USO
C.3
Vivienda
Oficina
Almacn
Depsito
Distancia
entre
perfiles
LUZ
3.0 m
4.0 m
5.0 m
6.0 m
3.0 m
4.0 m
5.0 m
6.0 m
Placa
Perfil
Perfil
Perfil
Perfil
Perfil
Perfil
Perfil
Perfil
0.407
14 mm
P6x2x1.2
P5x2x1.2
P6x2x1.5
P6x2-5/8x2.0
P10X2X1.2
P8x2-5/8x2.0
P10x2-5/8x1.5
P4x2x1.2
P6x2x1.2
P6x2x2.0
P10X2X1.2
P7x2-5/8x2.0
P10x2-5/8x1.5
0.488
17 mm
P6x2x1.2
P6x2x2.0
P10X2X1.2
P7x2-5/8x2.0
P10x2-5/8x1.5
P10x2-5/8x2.0
P9x2-5/8x2.0
P6x2x1.2
P5x2x1.2
P6x2x1.5
P6x2-5/8x2.0
P10X2X1.2
P8x2-5/8x2.0
P10x2-5/8x1.5
0.610
20 mm
P6x2x1.5
P6x2-5/8x2.0
P10X2X1.2
P8x2-5/8x2.0
P12x2-5/8x2.0
P6x2x1.2
P6x2x2.0
P10X2X1.2
P7x2-5/8x2.0
P10x2-5/8x1.5
P10x2-5/8x2.0
P9x2-5/8x2.0
0.407
14 mm
P6x2x1.2
P5x2x1.2
P6x2x2.0
P10X2X1.2
P7x2-5/8x2.0
P8x2-5/8x1.5
P10x2-5/8x2.0
P9x2-5/8x2.0
P6x2x1.2
P6x2x1.2
P6x2x1.5
P6x2-5/8x2.0
P10X2X1.2
P8x2-5/8x2.0
P10x2-5/8x1.5
0.488
17 mm
P6x2x1.2
P6x2x2.0
P10X2X1.2
P8x2-5/8x2.0
P10x2-5/8x1.5
P10x2-5/8x2.0
P9x2-5/8x2.0
P6x2x1.2
P5x2x1.2
P6x2x2.0
P10X2X1.2
P6x2-5/8x2.0
P10X2X1.2
P8x2-5/8x2.0
0.610
20 mm
P6x2x1.5
P6x2-5/8x2.0
P10X2X1.2
P10x2-5/8x2.0
P9x2-5/8x2.0
P12x2-5/8x2.0
P6x2x1.2
P6x2x2.0
P10X2X1.2
P8x2-5/8x2.0
P10x2-5/8x1.5
P10x2-5/8x2.0
P9x2-5/8x2.0
0.407
17 mm
P6x2x1.5
P6x2x1.5
P10x2-5/8x2.0
P9x2-5/8x2.0
P12x2-5/8x2.0
P6x2x1.2
P6x2-5/8x2.0
P10X2X1.2
P8x2-5/8x2.0
P10x2-5/8x1.5
P10x2-5/8x2.0
P9x2-5/8x2.0
0.488
20 mm
P6x2x2.0
P10X2X1.2
P7x2-5/8x2.0
P10x2-5/8x1.5
P10x2-5/8x2.0
P9x2-5/8x2.0
P12x2-5/8x2.5
P13x2-5/8x2.0
P6x2x1.5
P7x2-5/8x2.0
P8x2-5/8x1.5
P10x2-5/8x2.0
P9x2-5/8x2.0
P12x2-5/8x2.0
0.407
20 mm
P6x2x2.0
P10X2X1.2
P8x2-5/8x2.0
P10x2-5/8x1.5
P12x2-5/8x2.0
P12x2-5/8x2.5
P13-1/2x25/8x2.0
P6x2x2.0
P7x2-5/8x2.0
P10X2X1.2 P10x2-5/8x1.5
P10x2-5/8x2.0
P9x2-5/8x2.0
P12x2-5/8x2.5
0.488
20 mm
P6x2-5/8x2.0
P10x2-5/8x2.0
P9x2-5/8x2.0
P12x2-5/8x2.0
P6x2x2.0
P10X2X1.2
P12x2-5/8x2.0
P8x2-5/8x2.0
NOTAS:
- El presente diseo debe ser revisado por un ingeniero competente quien debe certificar la fidelidad de los procedimientos
y la aplicabilidad de su utilizacin.
- La informacin aqu incluida NO COMPROMETE a Perfilamos S.A., ni a ETERNIT, ni al ingeniero encargado de su desarrollo, ya que es de libre y voluntaria aplicacin.
- La tabla de clculo para entrepisos Livianos Perfilamos del Cauca S.A.
- ETERNIT, NO considera cargas puntuales superiores a 80 kg ni cargas de impacto.
- Las cargas consideradas corresponden a los valores definidos por la Norma Colombiana de Sismoresistencia 1998, de la
siguiente forma:
Vivienda 180 kg/m
Oficina 200 kg/m
Almacn Pequeo 350 kg/m
Depsito Liviano 500 kg/m
Acabados Livianos
Piso caucho, Alfombra 15 kg/m
Cielo falso en yeso 10 kg/m
Otras cargas 3 kg/m.
Acabados Pesados.
Enchape cermico, afinado en mortero 96 kg/m.
Cielo falso en yeso 10 kg/m.
Otras cargas 3 kg/m.
- Los perfiles deben ir en seccin sencilla y con riostras separadas mximas cada 2m.
- La deflexin mxima permitida en el diseo es L/240 (L: Luz).
- La materia prima utilizada en Perfilamos S.A es acero ASTM A-36 para los perfiles con espesores iguales o superiores a
1.5mm (Fy=25.3kg/mm) y ASTM A568 G33 para los de 1.2mm (Fy=23.2kg/mm).
64
Ejemplo 1
REFERENCIA
VALOR
CV
Viviendas
180 kg/m
Oficinas
180 kg/m
Comercio menor
180 kg/m
180 kg/m
180 kg/m
CM = W
75 a 120 kg/
m
CP
Sobrecargas e impactos
< 75 kg/m
3 a 6 ml
M (r)
122 a 244 cm
M (p)
40.7 - 48.8 y
61 cm
M (u)
122 a 244 cm
ENTREPISOS
3.
Teniendo en cuenta que la carga se
distribuye en el sentido ms corto, se tiene Luz=
5m, columna 6.
4.
Segn recomendaciones de soporte y
rendimiento, se tienen tres opciones de separacin
entre viguetas: 0.407m, 0.488m y 0.610m. En
consonancia con estas condiciones la seleccin
del perfil ser:
C.3
Tabla C.3.3
65
Ejemplo 2
Tmese el caso anterior pero con acabado en
alfombra:
Notas de clculo
1.
Sabiendo que el uso que se va a dar al
entrepiso es de vivienda, se busca en la primera
columna VIVIENDA.
ENTREPISOS
2.
Debido a que el acabado a instalar
es ligero, se considera un ENTREPISO CON
ACABADO LIVIANO.
C.3
3.
Teniendo en cuenta que la carga se
distribuye en el sentido ms corto, se tiene Luz=
5m, columna 10.
4.
Segn recomendaciones de soporte y
rendimiento, se tienen tres opciones de separacin
entre viguetas: 0.407m, 0.488m y 0.610m, de
acuerdo a esto la seleccin del perfil ser:
* P6x2 5/8x2.0, con una separacin
a ejes de 0.488m, y placas ETERBOARD de
17mm, columnas 2 y 3 respectivamente. Con
un rendimiento de 18un de perfiles metlicos
(9m/0.488m=18).
* P7x2 5/8x2.0, con una separacin
a ejes de 0.610m, y placas ETERBOARD de
20mm, columnas 2 y 3 respectivamente. Con
un rendimiento de 15un de perfiles metlicos
(9m/0.407m=15).
Finalmente se selecciona una de estas tres
opciones, segn disponibilidad y precios.
5.
Se deben instalar riostras separadas,
mximo cada 2m.
NORMAS DE CONSULTA
Los aceros utilizados para estos perfiles deben
cumplir con las normas relacionadas para ello,
ASTM A - 36, A 653, C 645, C 955, ASTM
570 (acero grado 3), NCR - 98 y otras.
66
C.4
CIELOS RASOS
SOLUCIONES CONSTRUCTIVAS
CIELOS RASOS
C.4
Entramados de
Estructura y
bastidor
Placas:
ETERBOARD (enteras
o en secciones
moduladas)
Cuelgas (bastones)
Anclajes
Fijaciones
Cintas
Sellos
Masillas
Pinturas
Texturas
Recubrimientos
Tabla C.4.1
De estos componentes ETERNIT fabrica las placas ETERBOARD, las masillas para el tratamiento de juntas y
superficies de uso exterior e interior y pinturas acrlicas y vinil acrlicas, especialmente diseadas para la aplicacin
sobre las placas ETERBOARD, adems de placas moduladas para cielos rasos en formato de 121,4 X 60,5 cm
que se suministran pintadas y con texturas.
68
CIELOS RASOS
Grfico C.4.2
Grfico C.4.5
C.4
Entramado en madera
La madera se ha usado ampliamente en la
construccin de entramados para cielos rasos,
pero debido a las implicaciones ambientales y
de normativas de prevencin de incendios se ha
disminuido su uso en la actualidad.
Piezas de 5 x 5 cm (durmientes), de 4 X 4 cm
(varillones) y de 2,5 x 5 cm (listones) unidos con
clavos, conforman los entramados. Los entramados
de madera son ms pesados que los metlicos,
por consiguiente se requiere que su sistema de
colgado sea el apropiado para soportar estas
mayores cargas. Es requisito estructural que las
cuelgas rgidas o bastones deben coincidir con
los nodos de unin y colocarse en cada uno de
ellos. Para el anclaje superior se deben utilizar
ngulos metlicos.
Grfico C.4.3
Grfico C.4.4
Grfico C.4.6
SISTEMA CONSTRUCTIVO EN SECO
69
CIELOS RASOS
C.4
6
8
4.12
Suspendidos planos
8.35
26.60
32.80
70
Grfica C.4.7.
REQUERIMIENTO
SISTEMAS UTILIZADOS
Cuelgas de
entramado
Fijacin de placas
CIELOS RASOS
C.4
71
CIELOS RASOS
IMPORTANTE
C.4
Grfico C.4.11
Modulaciones
72
El pleno
CIELOS RASOS
C.4
Grfico C.4.12
Arriostramientos
Las placas deben quedar fijadas por todos
sus lados al bastidor o entramado y para ello
se aprovechan los Omegas principales y las
Omegas de riostra en el sentido transversal, estas
secciones colocadas a manera de travesao
rigidizan el entramado y evitan los esfuerzos de
torsin.
La modulacin entre riostras es cada122 cm o
dependiendo del formato de la placa usada.
Las placas ETERBOARD de cielos rasos expuestas
a la humedad (baos, cocinas, aleros) en espacios
interiores o exteriores, deben ser tratadas
previamente con imprimante COLORCEL.
73
CIELOS RASOS
C.4
Grfico C.4.15
Grfico C.4.16
ETERBOARD
4 y 6 mm
Radio de arqueado 60 cm
8 y 10 mm
Radio de arqueado 80 cm
10 mm
74
CIELOS RASOS
Continuos - vs - artesonados
Grfico C.4.18
C.4
Grfico C.4.17
Grfico C.4.19
75
IMPORTANTE
Notas de clculo
CIELOS RASOS
C.4
NORMAS DE CONSULTA
- ASTM C-635 en cuanto a calidad y estndares
estructurales de los entramados.
- ASTM C-636 con lo relacionado a su instalacin
para garantizar su estabilidad. (NFPA 251,
ANSI/UL 263 e ICONTEC).
76
C.5
BASES DE CUBIERTA
SOLUCIONES CONSTRUCTIVAS
BASES DE CUBIERTA
Es la solucin constructiva que soporta el acabado final previsto para un techo, contemplando los
requerimientos de carga, vientos, impermeabilidad, insonoridad, aislamiento trmico y durabilidad.
Las bases de cubierta se utilizan para una variada gama de tejas y recubrimientos. La cara expuesta
al interior del volumen cubierto se puede dejar a la vista a manera de cielo raso o utilizar su estructura
para servir de soporte en la instalacin de uno.
C.5
C.5.2 COMPONENTES
Grfico C.5.2
Grfico C.5.1
Grfico C.5.4
C.5
Grfico C.5.3
BASES DE CUBIERTA
Proceso de armado
MODULACIONES BSICAS
Cada 61cm
Cada 48.8 cm
Cada 40.7 cm
Cada 30.5 cm
Tabla C.5.1
Grfico C.5. 5
Para cubiertas semipesadas
79
Bastidores de madera
IMPORTANTE
BASES DE CUBIERTA
C.5
ESPESOR (mm)
FORMATO (mm)
PESO (kg/Unidad)
10
1220 X 2440
42.00
14
1220 X 2440
57.40
ESPESOR (mm)
FORMATO (mm)
PESO (kg/Unidad)
1220 X 2440
32.80
Tabla C.5.2
Los espesores de las placas de ETERBOARD destinadas a bases de cubierta los determina el clculo
estructural que se realice. Para tal efecto, ETERNIT presenta la tabla 5.2 como gua.
Nota: Un mismo diseo de base de cubierta se
puede resolver con perfiles de distintas caractersticas
(medidas, calibres y modulaciones diferentes). As por
ejemplo, si utilizamos en una base de cubierta con
una solicitud especfica una modulacin de 61cmts
las viguetas debern ser de mayor especificacin en
alma y/o en calibre que si la modulacin fuera de
40,7cmts.
80
BASES DE CUBIERTA
Las placas ETERBOARD, se colocan perpendicularmente a las viguetas del bastidor, paralelas a las
riostras y alternadas (trabadas) unas con otras a la medida que permita la modulacin y el diseo,
con lo que se obtiene una mejor rigidez del diafragma. Se debe dejar un espacio o dilatacin entre
las placas de 3 milmetros como mnimo (junta de construccin), a la que posteriormente se le dar
tratamiento.
C.5
Detalle de fijacin 1
Detalle de emplacado
Detalle de fijacin 2
81
Subestructuras de apoyo
BASES DE CUBIERTA
PLACA ETERBOARD
C.5
14
14
10
10
mm
mm
mm
mm
BASTIDOR
PESO (kg/m)
Madera
Metal
Madera
Metal
30
27
25
23
Fibrocemento
Barro cocido
Cermicas
Cemento
Metlicas
Asflticas
TIPO
Onduladas
Acanaladas
PLANICEL rectangular
Tradicional
Prensadas
Moldeadas
Moldeadas
Onduladas
Trapezoidales
Dentadas o continuas
SUBESTRUCTURA
Depende de la
No
Depende de la
Depende de la
(listn o malla)
S
S
Depende de la
Depende de la
No
especificacin
especificacin
especificacin
especificacin
especificacin
82
Sellado e impermeabilizacin
C.5
Grfico 5.7
Grfico C.5.8
83
BASES DE CUBIERTA
C.5
Grfico C.5.10
Grfico C.5.9
Grfico C.5.11
84
con
PLANICEL
Base de cubierta
RECTANGULAR
C.5
Grfico C.5.14
85
BASES DE CUBIERTA
C.5
Grfico C.5.17
Acabado interior
Bases arqueadas
Las bases de cubiertas abovedadas se ejecutan
gracias a la facilidad de arqueado de las placas
ETERBOARD.
Para radios de curvatura de menos de 2mts se
requiere saturar de humedad las placas por
inmersin previa de 8 horas mnimo.
86
BASES DE CUBIERTA
TABLA DE CLCULO
PARA BASES DE CUBIERTA
CON PLACAS DE FIBROCEMENTO ETERBOARD Y PERFILES DE PERFILAMOS S.A.
BASE DE CUBIERTA CON TEJA DE BARRO
Distancia entre
perfiles
m
LUZ
3.0 m
3.5 m
4.0 m
4.5 m
5.0 m
5.5 m
6.0 m
Placa
Perfil
Perfil
Perfil
Perfil
Perfil
Perfil
Perfil
0.407
10 mm
P3x2x1.2
P5x2x1.2
P5x2x1.5
P6x2x1.5
P5x2x2.0
P6x2x2.0
P6x2x2.0
0.488
10 mm
P3x2x1.5
P4x2x1.5
P6x2x1.5
P5x2x2.0
0.607
10 mm
P4x2x1.5
P6x2x1.5
P5x2x2.0
P6x2x2.0
0.407
14 mm
P4x2x1.5
P6x2x1.5
P5x2x1.5
P5x2x2.0
P5x2x2.0
0.488
14 mm
P3x2x1.5
P4x2x1.5
P6x2x1.5
P5x2x2.0
P6x2x2.0
0.067
14 mm
P4x2x1.5
P4x2x2.0
P5x2x2.0
P6x2x2.0
P6x2x2.0
C.5
P6x2x2.0
NOTAS:
- El presente diseo debe ser revisado por un ingeniero competente quien debe certificar la fidelidad de los procedimientos y la aplicabilidad de su utilizacin.
- La informacin aqu incluida NO COMPROMETE a Perfilamos S.A., ni a ETERNIT, ni al ingeniero encargado de
su desarrollo, ya que es de libre y voluntaria aplicacin.
- Las cargas consideradas corresponden a los valores definidos por la Norma Colombiana de Sismoresistencia
1998, de la siguiente forma:
- Peso teja de barro 80 kg/m.
- Peso correas 5 kg/m.
- Cielo Raso 10 kg/m.
- Otras Carga 5 kg/m.
El peso de las placas fue considerado de la siguiente forma:
- Placas de Fibrocemento ETERBOARD 10mm 42.08 kg/un.
- Placas de Fibrocemento ETERBOARD 14mm 58.91 kg/un.
- Los perfiles deben ir en seccin sencilla, con riostras separadas cada L/2 (L:Luz) mximo 2m.
Los perfiles sombreados requieren dos lneas de tirantes.
- La pendiente considerada es de 9 (16%).
- La materia prima utilizada en Perfilamos S.A es acero ASTM A-36, para los perfiles con espesores iguales o superiores a 1.5mm (Fy=25.3kg/mm) y ASTM A568 G33 para los de 1.2mm (Fy=23.2kg/mm).
87
TABLA DE CLCULO
PARA BASES DE CUBIERTA
CON PLACAS DE FIBROCEMENTO ETERBOARD Y PERFILES DE PERFILAMOS S.A.
BASES DE CUBIERTA
C.5
Distancia entre
perfiles
m
LUZ
3.0 m
3.5 m
4.0 m
4.5 m
5.0 m
5.5 m
6.0 m
Placa
Perfil
Perfil
Perfil
Perfil
Perfil
Perfil
Perfil
0.407
10 mm
P3x2x1.2
P3x2x1.2
P4x2x1.2
P5x2x1.2
P5x2x1.5
P6x2x1.5
P6x2x1.5
0.488
10 mm
P3x2x1.2
P3x2x1.2
P3x2x1.5
P4x2x1.5
P6x2x1.5
P5x2x2.0
P5x2x2.0
0.607
10 mm
P3x2x1.2
P3x2x1.5
P4x2x1.5
P6x2x1.5
P5x2x2.0
P6x2x2.0
P6x2x2.0
0.407
14 mm
P3x2x1.2
P3x2x1.2
P4x2x1.2
P5x2x1.2
P5x2x1.5
P6x2x1.5
P6x2x1.5
0.488
14 mm
P3x2x1.2
P4x2x1.2
P5x2x1.2
P5x2x1.5
P6x2x1.5
P5x2x2.0
P5x2x2.0
0.067
14 mm
P3x2x1.2
P3x2x1.5
P5x2x1.2
P6x2x1.5
P5x2x2.0
P6x2x2.0
P6x2x2.0
NOTAS:
- El presente diseo debe ser revisado por un ingeniero competente quien debe certificar la fidelidad de
los procedimientos y la aplicabilidad de su utilizacin.
- La informacin aqu incluida NO COMPROMETE a Perfilamos S.A., ni a ETERNIT, ni al ingeniero encargado
de su desarrollo, ya que es de libre y voluntaria aplicacin.
- Las cargas consideradas corresponden a los valores definidos por la Norma Colombiana de
Sismoresistencia 1998, de la siguiente forma:
- Peso teja 13.8 kg/m
- Peso correas 5 kg/m
- Cielo Raso 10 kg/m
- Otras Carga 5 kg/m
El peso de las placas fue considerado de la siguiente forma:
- Placas de Fibrocemento ETERBOARD 10mm 42.08 kg/un.
- Placas de Fibrocemento ETERBOARD 14mm 58.91 kg/un.
- Los perfiles deben ir en seccin sencilla, con riostras separadas cada L/2 (L:Luz) mximo 2m.
Los perfiles sombreados requieren dos lneas de tirantes.
- La pendiente considerada es de 1 (1.6%).
- La materia prima utilizada en Perfilamos S.A es acero ASTM A-36, para los perfiles con espesores iguales o
superiores a 1.5mm (Fy=25.3kg/mm) y ASTM A568 G33 para los de 1.2mm (Fy=23.2kg/mm).
88
TABLA DE CLCULO
PARA BASES DE CUBIERTA
CON PLACAS DE FIBROCEMENTO ETERBOARD Y PERFILES DE PERFILAMOS S.A.
Distancia entre
perfiles
m
LUZ
3.0 m
3.5 m
4.0 m
4.5 m
5.0 m
5.5 m
6.0 m
Placa
Perfil
Perfil
Perfil
Perfil
Perfil
Perfil
Perfil
0.407
10 mm
P3x2x1.2
P3x2x1.2
P3x2x1.2
P4x2x1.2
P6x2x1.2
P5x2x1.5
P5x2x1.5
0.488
10 mm
P3x2x1.2
P3x2x1.2
P4x2x1.2
P6x2x1.2
P5x2x1.5
P5x2x2.0
P5x2x2.0
0.607
10 mm
P3x2x1.2
P4x2x1.2
P6x2x1.2
P5x2x1.5
P5x2x2.0
P6x2x2.0
P5x2x2.0
0.407
14 mm
P3x2x1.2
P3x2x1.2
P4x2x1.2
P5x2x1.2
P4x2x1.5
P6x2x1.5
P6x2x1.5
0.488
14 mm
P3x2x1.2
P3x2x1.2
P3x2x1.5
P4x2x1.5
P6x2x1.5
P5x2x2.0
P5x2x2.0
0.067
14 mm
P3x2x1.2
P4x2x1.2
P4x2x1.5
P6x2x1.5
P5x2x2.0
P6x2x2.0
P6x2x2.0
BASES DE CUBIERTA
C.5
NOTAS:
- El presente diseo debe ser revisado por un ingeniero competente quien debe certificar la fidelidad de los procedimientos y la aplicabilidad de su utilizacin.
- La informacin aqu incluida NO COMPROMETE a Perfilamos S.A., ni a ETERNIT, ni al ingeniero encargado de
su desarrollo, ya que es de libre y voluntaria aplicacin.
- Las cargas consideradas corresponden a los valores definidos por la Norma Colombiana de Sismoresistencia
1998, de la siguiente forma:
- Peso teja 7 kg/m.
- Peso correas 5 kg/m.
- Cielo Raso 10 kg/m.
- Otras Carga 5 kg/m.
El peso de las placas fue considerado de la siguiente forma:
- Placas de Fibrocemento ETERBOARD 10mm 42.08 kg/un.
- Placas de Fibrocemento ETERBOARD 14mm 58.91 kg/un.
- Los perfiles deben ir en seccin sencilla, con riostras separadas cada L/2 (L:Luz) mximo 2m. Los perfiles sombreados requieren dos lneas de tirantes.
- La pendiente considerada es de 1 (1.6%).
- La materia prima utilizada en Perfilamos S.A es acero ASTM A-36, para los perfiles con espesores iguales o superiores a 1.5mm (Fy=25.3kg/mm) y ASTM A568 G33 para los de 1.2mm (Fy=23.2kg/mm).
89
TABLA DE CALCULO
PARA BASES DE CUBIERTA
CON PLACAS DE FIBROCEMENTO ETERBOARD Y PERFILES DE PERFILAMOS S.A.
BASES DE CUBIERTA
C.5
Distancia entre
perfiles
m
LUZ
3.0 m
3.5 m
4.0 m
4.5 m
5.0 m
5.5 m
6.0 m
Placa
Perfil
Perfil
Perfil
Perfil
Perfil
Perfil
Perfil
0.407
10 mm
P3x2x1.2
P3x2x1.2
P4x2x1.2
P5x2x1.2
P5x2x1.5
P6x2x1.5
P6x2x1.5
0.488
10 mm
P3x2x1.2
P3x2x1.2
P3x2x1.5
P4x2x1.5
P6x2x1.5
P5x2x2.0
P5x2x2.0
0.607
10 mm
P3x2x1.2
P3x2x1.5
P4x2x1.5
P6x2x1.5
P5x2x2.0
P6x2x2.0
P6x2x2.0
0.407
14 mm
P3x2x1.2
P3x2x1.2
P4x2x1.2
P5x2x1.2
P5x2x1.5
P6x2x1.5
P6x2x1.5
0.488
14 mm
P3x2x1.2
P4x2x1.2
P5x2x1.2
P5x2x1.5
P6x2x1.5
P5x2x2.0
P5x2x2.0
0.067
14 mm
P3x2x1.2
P3x2x1.5
P5x2x1.5
P6x2x1.5
P5x2x2.0
P6x2x2.0
P6x2x2.0
NOTAS:
- El presente diseo debe ser revisado por un ingeniero competente quien debe certificar la fidelidad de los procedimientos y la aplicabilidad de su utilizacin.
- La informacin aqu incluida NO COMPROMETE a Perfilamos S.A., ni a ETERNIT, ni al ingeniero encargado de
su desarrollo, ya que es de libre y voluntaria aplicacin.
- Las cargas consideradas corresponden a los valores definidos por la Norma Colombiana de Sismoresistencia
1998, de la siguiente forma:
- Peso recubrimiento 15 kg/m.
- Peso correas 5 kg/m.
- Cielo Raso 10 kg/m.
- Otras Carga 5 kg/m.
El peso de las placas fue considerado de la siguiente forma:
- Placas de Fibrocemento ETERBOARD 10mm 42.08 kg/un.
- Placas de Fibrocemento ETERBOARD 14mm 58.91 kg/un.
- Los perfiles deben ir en seccin sencilla, con riostras separadas cada L/2 (L:Luz) mximo 2m. Los perfiles ombreados requieren dos lneas de tirantes.
- La pendiente considerada es de 1 (1.6%).
- La materia prima utilizada en Perfilamos S.A es acero ASTM A-36, para los perfiles con espesores iguales o superiores a 1.5mm (Fy=25.3kg/mm) y ASTM A568 G33 para los de 1.2mm (Fy=23.2kg/mm).
90
Notas de clculo
BASES DE CUBIERTA
Ejemplo de clculo
Grfico C.5.18
1.
Teniendo en cuenta que los perfiles se
instalan en el sentido perpendicular a la cada
del agua, se tiene Luz= 6m, columna 9.
C.5
2.
Segn recomendaciones de soporte
y rendimiento, se tienen dos opciones
de ETERBOARD: 10mm y 14mm. De
acuerdo a esto la seleccin del perfil ser:
* Se puede instalar P6x2x2.0, con una separacin
a ejes de 0.407m, y placas ETERBOARD
de 10mm, columnas 1 y 2 respectivamente.
* Se puede instalar P6x2 5/8x2.0, con una
separacin a ejes de 0.488m, y placas ETERBOARD
de 14mm, columnas 1 y 2 respectivamente.
Finalmente se selecciona una de estas opciones,
segn disponibilidad y precios en el mercado.
Se deben instalar riostras separadas mximo
cada 2m.
NORMAS DE CONSULTA
ASTM C 955: Perfiles portantes.
ASTM C 1007: Instalacin de perfiles portantes.
NTC 4373 ISO 8336: Placas de fibrocemento.
91
BASES DE CUBIERTA
C.5
92
D.
CONSIDERACIONES FINALES
CONSIDERACIONES FINALES
Temas tratados:
D.1 Tratamiento de juntas.
D.2 Equipos, herramientas y elementos de
seguridad
94
D.1
TRATAMIENTO DE JUNTAS
CONSIDERACIONES FINALES
TRATAMIENTO DE JUNTAS
D.1
Grfico D.1.4 Detalle de junta invisible
96
TRATAMIENTO DE JUNTAS
D.1
BORDE REBAJADO
IMPORTANTE
Las placas de ETERBOARD son fraguadas en
autoclave, proceso que logra un material de alta
estabilidad dimensional. Sin embargo, debido
a los cambios de temperatura y humedad, se
presentan movimientos de expansin o contraccin
estructural; para prevenir fallas por esta condicin,
en los encuentros del cielorraso contra estructuras
o muros y particularmente los construidos en
sistemas y materiales diferentes se deben colocar
juntas flexibles o de control en el permetro y cada
25 m de rea de cielo raso.
97
TRATAMIENTO DE JUNTAS
PASO 1
2.
Fijar la cinta de fibra de vidrio
inmediatamente antes de que seque la primera
capa, retirando el exceso de pasta. Tener cuidado
en fijar firmemente la cinta, evitando que quede
despegada de las orillas o forme ondulaciones.
Dejar secar de 15 a 20 minutos.
D.1
PASO 2
3.
Aplicar una segunda capa de ETERCOAT
(HR o MR) utilizando una esptula de 10,
cubriendo y rebasando la cinta de fibra de
vidrio.
Una aplicacin plana y sin resaltos facilita el
obtener un tratamiento de la junta y superficie lisa
y pareja.
PASO 3
4.
Despus de 24 horas, en caso de existir
imperfecciones en la superficie tratada, raspar
con una esptula y aplicar ETERGLASS (HF High
Flexibility o MF Medium Flexibility) sobre toda la
superficie de la placa.
PASO 4
98
TRATAMIENTO DE JUNTAS
Notas de clculo
D.1
Grfico D.1.8
99
TRATAMIENTO DE JUNTAS
D.1
100
d.2
EQUIPOs, HERRaMIENTas Y
ELEMENTOs dE sEGURIdad
cONsIdERacIONEs FINaLEs
EQUIPOS Y HERRAMIENTAS
Para las construcciones en seco se utilizan un gran nmero de herramientas manuales, elctricas con
cables, inalmbricas y neumticas, accionadas por bateras, aire, plvora o gas y de las cuales se debe
conocer su funcionamiento, aplicacin, alcance y recomendaciones del fabricante.
D.2
Para este tipo de construcciones se consideran cinco reas de aplicacin de las herramientas, equipos
apropiados y elementos de seguridad para el trabajo.
Un operario dotado de las herramientas, equipos y elementos adecuados a la labor a realizar, garantiza
rendimiento, calidad y seguridad en su desempeo y obra ejecutada. ETERNIT tiene como compromiso
divulgar que esta recomendacin se cumplan a cabalidad.
La proteccin personal y de las reas de trabajo son de uso obligatorio, no slo por cumplir con los
requisitos de seguridad personal e industrial, sino tambin para garantizar un excelente resultado de
los trabajos que se realicen ya que con el uso de estos equipos se facilita el accionar de los operarios
y la proteccin de los espacios a intervenir.
d.2.1 reas de aplicacin
APLICACIN
HERRAMIENTAS Y EQUIPO
1. Movilizacin,
colocacin y sustentacin
zancos,
2. Medicin trazado y
nivelacin
3. Cortes y armado de
bastidores
4. Anclaje y emplacado
5. Tratamiento de juntas y
superficies
Tabla D.2.1
IMPORTANTE
Toda accin o trabajo que se ejecute sobre un material o componente del sistema constructivo en seco
ETERNIT, se considera como una transformacin del mismo, la cual puede ocasionar recortes, residuos
u otros sobrantes los cuales se deben disponer en bolsas o recipientes adecuados para su desalojo de
la obra.
Especial cuidado con los recortes y sobrantes de perfiles metlicos que pueden ocasionar punzadas o
cortes en la piel.
Al cortar placas de FC ETERBOARD, usar sierras circulares o caladoras, de baja velocidad, con discos
o cuchillas para el material trabajado, con equipos de aspiracin se debe evitar la propagacin y
aspiracin de polvo, el cual contiene slice que puede afectar los ojos y las vas respiratorias.
102
El uso de zancos para obtener una mayor altura del operario, requiere experiencia en su uso, ya que
si no se les maneja adecuadamente pueden causar accidentes de trabajo. Se debe evitar el armado
de andamios y escaleras con elementos no apropiados, lo que presenta riesgos por su inestabilidad y
forma. Es indispensable que todo instalador tenga como mnimo un ayudante.
RODADORES Y CARRETAS
Transporte de placa
PRENSAS AUTOMTICAS
Sujetan las placas al paral
ANDAMIOS
Acceder a partes altas
EQUIPOS Y HERRAMIENTAS
Generalmente, los elementos y materiales de las construcciones en seco se pueden movilizar por
una o dos personas (placas, perfiles, masillas) o con el uso de rodadores, sustentadores y para los
denominados trabajos manos libres, se utilizan elevadores de pie, de placa y prensas.
D.2
BANCOS
Acceder a partes altas
ESCALERAS
Acceder a partes altas
ZANCOS
Mayor altura del instalador
SUSTENTADORES
Sostenedores de placas
ELEVADORES DE PIE
Para dilatar del piso
ELEVADORES DE PLACA
(panel jack)
Tabla D.2.2
IMPORTANTE
El rendimiento de una obra depende de manera importante de los elementos de movilizacin, colocacin
y sustentacin de las personas y elementos del sistema ya que si no se facilitan estas labores los tiempos
de ejecucin se incrementan notablemente.
103
EQUIPOS Y HERRAMIENTAS
Hoy da el mercado ofrece una variedad de instrumentos de medicin y nivelacin lser, que aparte de
su bajo costo y alto desempeo, facilitan estas labores de una forma sencilla y garantizada.
CINTAS, FLEXMETROS
Metlicas o de nylon
METRO DE CARPINTERO
Mide y da escuadras
DISTANCIMETROS
Medicin por lser
D.2
NIVEL LASER
Nivela y aploma
NIVEL DE BURBUJA
Nivela
CALIBRADORES DE ESPESOR
Mide placas y lminas
PLOMADA
Aploma por gravedad
REGLAS, ESCUADRAS Y
TRANSPORTADORES
Tabla D.2.3
IMPORTANTE
Del trazado, nivelacin y marcacin depende el buen acabado de la obra. Las alturas, vanos y
modulaciones, requieren de mediciones acertadas para garantizar la forma, tamao y ubicacin de los
bastidores as como un ajuste perfecto para el emplacado.
104
Para el corte de las placas de fibrocemento ETERBOARD, se recomienda usar un rayador el cual
despus de varias pasadas por la marca de corte, permite mediante un esfuerzo de doblez, obtener
cortes precisos y rpidamente, evitando la generacin de polvo. Cuando no se dispone de un rayador
y si las lneas de corte exigen el uso de una herramienta elctrica, tal como sierra de sable, caladora,
pulidora o sierra circular, estas deben tener control de accionamiento para baja velocidad, ya que as
el corte forma secciones de viruta y no generan mucho polvo el cual es nocivo para la salud. El uso de
equipos de proteccin es indispensable y obligatorio en esta labor. Todas las mquinas modernas de
corte traen aditamentos para usar sistemas de aspiracin, los que se encargan de retener el polvo y
facilitar su disposicin posterior. El seguimiento de estas prcticas garantiza salubridad operacional.
TRONZADORA DE PERFILES
Corte con pulidora
SIERRA CIRCULAR
Mampostera baja velocidad
CALADORA Y RUTEADORA
Cortes a baja velocidad
EQUIPOS Y HERRAMIENTAS
D.2
SIERRA DE SABLE
Corte de calado
TIJERAS
De hojalata y aviador
CORTADOR Y RAYADOR
Corte por cuchilla y rallado
ATORNILLADOR
Elctrico de cable o pila
DESTORNILLADORES
Manuales, puntas
REMACHADORAS y PUNZONADORAS
Tabla D.2.3
105
TALADROS PERCUTORES
D.2
TALADROS REVERSIBLES
BROCAS
Perforaciones duras
ATORNILLADOR Y PUNTAS
Cortas largas
PISTOLAS DE FIJACIN
A plvora
Con gas
CLAVADORA AUTOMTICA
PISTOLAS DE FIJACIN
MARTILLOS
De bola, ua y masa
DESTORNILLADORES,
LLAVES y DADOS
Tabla D.2.4
IMPORTANTE
Con las herramientas de anclaje y emplacado se debe prestar gran atencin en su uso ya que
presentan el mayor nmero de riesgos de accidente por su mal uso, distraccin del operario o por
falta de mantenimiento de las mismas. Conocer y entender sus manuales de uso y funcionamiento es un
requerimiento imperativo.
106
EQUIPOS DE MASILLADO
Aplicacin con bomba
EQUIPOS Y HERRAMIENTAS
BANJO
Coloca Cinta y masilla
ESPTULAS Y CUBETAS
Para masillar
D.2
LIJADORAS MANUALES
Y ESCOFINAS
EQUIPO DE TEXTURAS
Aplicador de texturas
OTRAS ESPTULAS
Esquina, plano y rincn
RODILLOS Y BROCHAS
Aplicacin de pinturas
EQUIPO DE PINTURA
LIJADORAS Y LIJAS
Tabla D.2.5
107
EQUIPOS Y HERRAMIENTAS
D.2
En ETERNIT La seguridad personal es prioridad de las construcciones en seco. Aunque estas construcciones
generan menores riesgos que la construccin tradicional, no se deben descuidar las normas mnimas
de seguridad y su aplicacin como parte de las buenas prcticas constructivas recomendadas en este
manual. Los riesgos principales estn en la manipulacin de los perfiles de acero laminado por sus
bordes cortantes, el polvo generado por cortes con equipos inapropiados y la manipulacin indebida
de herramientas de corte a disco y sable.
MASCARILLAS
PRENSAS AUTOMTICAS
Desechables
GAFAS DE PROTECCIN
BOTIQUN DE AUXILIOS
MASCARILLAS
Reutilizables
GUANTES DE NITRILO
Para masillar y dar acabados
CINTURN Y BOLSA
Porta herramientas y otros
ROPA DE TRABAJO
Tabla D.2.6
108
BOTAS DE TRABAJO
ETERNIT COLOMBIANA
Cra 7 N. 26 - 20 Piso 16
Planta Mua: Km. 1 Va Silvania
PBX: (1) 730 69 00 A.A. 4256
Lnea Gratuita 018000-115660
Fax: (1) 323 81 76 - (1) 323 8177
E-mail: sistema.constructivo@eternit.com.co
Bogot D.C. Colombia
ETERNIT ATLNTICO
Va 40 Carrera 67 Zona Ind. Loma 3
PBX: (5) 350 38 00
Lnea Gratuita 018000-958094
Fax: (5) 350 38 14 - A.A. 853
E-mail: eternit.atlantico@eternit.com.co
Barranquilla - Atlntico. Colombia
ETERNIT PACFICO
Puerto Isaacs Yumbo. Km 15
PBX: (2) 608 85 00
Lnea Gratuita 018000-123800
Fax: (2) 608 85 65 - A.A. 1279
E-mail:serviciosadmin.pac@eternit.com.co
Yumbo - Valle. Colombia
Contctenos
www.eternit.com.co