Skirt Data :
Skirt Outside Diameter at Base
Skirt Thickness
Skirt Internal Corrosion Allowance
Skirt External Corrosion Allowance
Skirt Material
Basering Input:
SOD
STHK
SCA
3509.9495
40.0000
0.0000
1.5000
SA-283 C
mm.
mm.
mm.
mm.
Thickness of Basering
Design Temperature of the Basering
Basering Matl
Basering Operating All. Stress
Basering Yield Stress
Inside Diameter of Basering
Outside Diameter of Basering
Nominal Diameter of Bolts
Bolt Corrosion Allowance
Root Area of a Single Bolt
Bolt Material
Bolt Operating Allowable Stress
Number of Bolts
Diameter of Bolt Circle
TBA
BASOPE
DI
DOU
mm.
C
KG/CM2
KG/CM2
mm.
mm.
64.0000
0.0000
2857.5701
IS 2062 GR.B
1345.00
28
3720.0000
mm.
mm.
sq.mm.
FPC
FC
255.0
91.0
9.833
KG/CM2
KG/CM2
20.0000
200.0000
200.0000
2038900.0
2108.2
216.0000
145.0000
72.5000
2
mm.
mm.
mm.
KG/CM2
KG/CM2
mm.
mm.
mm.
SA
RN
DC
KG/CM2
mm.
TTA
TOPWTH
BHOLE
46.0000
200.0000
69.0000
mm.
mm.
mm.
CA
0.0000
mm.
DW
ROW
TW
EQMOM
WIMOM
Vormom
267875.7
277364.6
648510.1
348345.5
1246306.2
126741.5
KG
KG
KG
KG-M
KG-M
KG-M
[EarthQuake Case]
[WindLoad Case]
TM
ppl
138386.2
138386.2
561999.4
100.0
KG-M
KG-M
KG-M
BND
BCA
Area
38.0000
38.00
SA-283 C
1103.82
2108.22
3230.0000
3910.0000
Fact
No
No
1.0000
(UEQMOM)
(UWIMOM)
PV Elite has 2 different design methods for computing the required thickness of Basering supports.
1: The simplified method will design thicker basering
The approximate method simply calculates the compressive load on the concrete assuming that the neutral
axis for the vessel is at the centerline.
2: The Neutral Axis Shift Method will design thinner basering
when a steel skirt and base ring are supported on a concrete foundation, the behavior of the foundation is
similar to that of a reinforced concrete beam. If there is a net bending moment on the foundation, then the
force upward on the bolts must be balanced by the force downward on the concrete. But because these two
materials have different modulas of elasticity, and because the strain in the concrete cross section must be
equal to the strain in the base ring at any specific location, then the neutral axis of the combined
bolt/concrete cross section will be shifted in the direction of the concrete.
For baserings that are located on a steel substructure the recommendation is to use the simplified method.
Otherwise for the traditional basering on concrete use either method.
Governing Bolt Load Condition, Wind + Dead Weight Condition:
Area Available in one Bolt
Abss :
2857.5701
Area Available in all the Bolts
Abss * RN :
80011.9609
sq.mm.
sq.mm.
k
0.180
0.315
0.326
0.318
0.320
0.320
knew
0.270
0.337
0.321
0.319
0.320
0.319
Cc
1.153
1.549
1.579
1.557
1.562
1.562
Ct
2.705
2.409
2.385
2.403
2.399
2.399
z
0.463
0.434
0.432
0.434
0.433
0.433
j
0.774
0.782
0.782
0.782
0.782
0.782
Ft
320727.2
327373.8
328032.6
327537.1
327660.2
327639.6
Fc
91252.3
92282.7
92384.8
92308.0
92327.1
92323.9
Based on above factors & Eq. 10.24 & 10.27 we have to find tensile force Ft & compressive force Fc
Than with eq. no. 10.30 is used to find eq. no. 10.30
Note if value
b/l is coming less than 1.Than invert b/l to l/b & find values of gama 1 & 2
There are two different equation for Mx & My based on this ratio b/l it will govern
b/l = 1 than Mx = My
b/l > 1 than My > Mx
Bending stress is =
Stpe -7 Skirt thickness due to reaction of bolting chair & compression ring
Req.
=
=
=
36.5732
38.0000
44.2036
46.0000
15.1823
20.0000
38.4846
40.0000
187.8270
16.2454
6.3978
9.5700
9.5700
mm.
mm.
mm.
mm.